Supported Features

Supported Features for Conversion

A. Supported Features for Conversion from UCS Manager/Central to IMM

This section provides a list of features that are supported for conversion in the IMM Transition Tool and a policy mapping between Cisco UCS Manager/Central and Intersight.


Note


If the UCS Central configuration contains VLAN/VSAN aliasing, the IMM Transition Tool will automatically select one of the aliases when performing the conversion of the vNICs/vHBAs. Please review the resulting configuration carefully to make sure it is appropriate.


Table 1. (I) Conversion Mapping between UCS Manager/Central and Intersight Features
UCS Manager/ UCS Central Feature Category Source UCS Manager/UCS Central Feature Name Equivalent IMM Policy
Admin

Communication Services

Note: Sessions/HTTP settings are defined in Intersight Settings. Telnet/SSH settings are not supported.

SNMP Policy

Organizations

Intersight Organizations

Syslog

Note: Only supports up to two remote destination servers

Syslog Policy

Time zone Management

NTP Policy

MAC Address Table Aging

Switch Control Policy

VLAN Port Count Optimization

Switch Control Policy

Reserved VLAN Range

Note: Supported in IMM Transition Tool, Release 4.0.1 and later.

Switch Control Policy

Inband Profile VLAN Group

Ethernet Network Group Policy

Inband Profile Network

IMC Access Policy

Inband Profile IP Pool Name

IMC Access Policy

FC Uplink Trunking

VSAN Policy

DNS

Note: In UCS Manager, it is found under Admin > Communication Management > DNS Management

Network Connectivity Policy

LDAP Authentication Domain

Note: Supported in IMM Transition Tool, Release 5.1.1 and later.

Intersight LDAP Policy and/or Intersight Appliance Authentication Domain

Note

 
  • If the destination Intersight device is SaaS, the system creates and attaches an LDAP policy to the Domain Profile. For an Appliance device, it creates both the Intersight LDAP policy and the Intersight Appliance Authentication Domain from UCSM LDAP to enable LDAP/AD login on the appliance depending on the default settings during the conversion.

  • When converting from UCS Central, tool enables the conversion of LDAP/AD Authentication from UCS Central (UCSC) to the target Intersight appliance device.

Server Policies and Chassis Policies

BIOS Policy

BIOS Policy

Boot Policy

Boot Policy

iSCSI Static Target Policy

Disk Group Policy

Storage Policy

IPMI Access Profile

IPMI over LAN Policy

iSCSI Adapter Policy

iSCSI Adapter Policy

iSCSI Boot Policy

iSCSI Boot Policy

KVM Management Policy

Virtual KVM Policy

Local Disk Config Policy

Note: Replaced by Storage Policy. Local Disk Configuration policy supports only Manual creation not the Automatic policy option.

Storage Policy, SD Card Policy

QoS Policy

Ethernet QoS Policy/ FC QoS Policy

Serial over LAN Policy

Serial over LAN Policy

Service Profile

Server Profile

Service Profile Template

Note: Only Updating Templates - no support for Initial Templates (though cloning can be achieved)

Server Profile Template

Storage Profile

Storage Policy

Storage Profile - Security Policy

Note: Supported in IMM Transition Tool, Release 4.0.1 and later.

Drive Security

vMedia Policy

Virtual Media Policy

vNIC/vHBA Placement Policy

Note: The placement is statically mapped to PCIe slots, with the following mapping:

  • vCon 1: Slot MLOM

  • vCon 2: Slot PCIe1

  • vCon 3: Slot PCIe2

  • vCon 4: Slot PCIe3

This mapping is static, but can be adjusted in the Transition Settings. For more details, see B. Transition Settings for Conversion section in Default Settings.

LAN Connectivity Policy/SAN Connectivity Policy

Ethernet Adapter Policy

Ethernet Adapter Policy

Flow Control Policy

Flow Control Policy

LACP Policy

Link Aggregation Policy

LAN Connectivity Policy

LAN Connectivity Policy

VMQ Connection Policy

VMQ

usNIC Connection Policy

usNIC

Note: Part of LAN Connectivity policy

SRIOV HPN Connection Policy

SR-IOV

Link Protocol Policy

Switch Control Policy

Multicast Policy

Multicast Policy

Network Control Policy

Ethernet Network Control Policy

Fibre Channel Adapter Policy

Fibre Channel Adapter Policy

SAN Connectivity Policy

SAN Connectivity Policy

Storage Connection Policy

FC Zoning Policy

Power Control Policy

Power Restore BIOS setting

Power Policy

vNIC Template

vNIC Template

vHBA Template

vHBA Template

—

Chassis Profile Template

Note:Chassis Profile Template is created by using converted power and thermal policies from the global policies section of the UCS Manager.

Memory Policy

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

Memory Policy

Scrub Policy

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

Scrub Policy

Server Pool Qualification Policy

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

Server Pool Qualification Policy

MACsec Policy

Note: Supported in IMM Transition Tool, Release 5.1.1 and later.

MACsec Policy

Host Firmware Package Policy

Note: Supported in IMM Transition Tool, Release 5.1.3 and later.

Firmware Policy

ID Range Access Control Policy

Note

 

Conversion support is available only from UCS Central to IMM and is supported in the IMM Transition Tool, Release 5.1.4 and later.

ID Mapping Policy

Pools

IP Pool

IP Pool

IQN Suffix Pool

IQN Pool

MAC Pools

MAC Pool

WWNN Pool

WWNN Pool

WWPN Pool

WWPN Pool

Server Pool

Note: Supported in IMM Transition Tool, Release 1.0.2 and later.

Resource Pool

Following table lists the UCS Manager features that are supported for conversion in the IMM Transition Tool.

Table 2. (II) Conversion Mapping between UCS Manager and Intersight Features
UCS Manager Feature Category Source UCS Manager Feature Name Equivalent IMM Policy
Fabric Config

Note: Merged with regular VLANs

Appliance VLAN

VLAN Policy

QoS System Class

System QoS Policy

VLAN Group

Note: IMM Transition Tool, Release 4.1.2 supports VIC QinQ Tunneling

Ethernet Network Group Policy

VLAN

VLAN Policy

VSAN

VSAN Policy

Storage VSAN

Note: Supported in IMM Transition Tool, Release 1.0.2 and later.

VSAN Policy

LAN/SAN Pin Group

Note:

  • Supported in IMM Transition Tool, Release 3.0.1 and later.

  • Table containing aliases for aliased VLANs/VSANs are not supported for conversion.

LAN/SAN Pin Group

Fabric Policies

Note: Merged with regular Network Control Policies

Appliance Network Control Policy

Ethernet Network Control Policy

UDLD Link Policy

Link Control Policy

Fabric Interconnect Audit Logs

Note

 

Supported in IMM Transition Tool, Release 5.1.4 and later.

AuditD Policy

Port Roles

Appliance Port

Port Policy

Appliance Port-Channel

Port Policy

FCoE Uplink Port

Port Policy

FCoE Uplink Port-Channel

Port Policy

LAN Uplink Port

Port Policy

LAN Uplink Port-Channel

Port Policy

SAN Unified Port

Port Policy

SAN Uplink Port

Port Policy

SAN Uplink Port-Channel

Port Policy

Server Port

Port Policy

FC Storage Port

Note: Supported in IMM Transition Tool, Release 1.0.2 and later.

Port Policy

SAN Storage Port

Note: Supported in IMM Transition Tool, Release 1.0.2 and later.

Port Policy

Breakout Port

Note:

  • Supported in IMM Transition Tool, Release 3.0.1 and later.

  • Table containing aliases for aliased VLANs/VSANs are not supported for conversion.

Port Policy

B. Fabric Interconnect (FI) Mapping for Conversion

When a Port policy is converted from UCSM to IMM, the port configuration of that policy is adjusted by mapping the unsupported FI (Cisco UCS 6200 and 6300 Series) as shown below:

Table 3. Mapping between UCSM FI and IMM FI for Port Policy Conversion
UCSM FI Equivalent IMM FI
Cisco UCS-FI-6664

Cisco UCS-FI-6664

Note: Supported in IMM Transition Tool, Release 5.1.2 and later.

Cisco UCSX-S9108-100G

Cisco UCSX-S9108-100G

Note: Supported in IMM Transition Tool, Release 4.2.2 and later.

Cisco UCS-FI-6536 Cisco UCS-FI-6536
Cisco UCS-FI-64108 Cisco UCS-FI-64108
Cisco UCS-FI-6454 Cisco UCS-FI-6454
Cisco UCS-FI-6332-16UP Cisco UCS-FI-6536
Cisco UCS-FI-6332 Cisco UCS-FI-6536
UCS-FI-M-6324

Cisco UCS-FI-6454

Note: Supported in IMM Transition Tool, Release 4.2.1 and earlier.

Cisco UCSX-S9108-100G

Note: Supported in IMM Transition Tool, Release 4.2.2 and later.

Cisco UCS-FI-6296UP Cisco UCS-FI-64108
Cisco UCS-FI-6248UP Cisco UCS-FI-6454

Note


  • Any existing Unified Port and SAN Port configuration will be ignored when converting from a Cisco UCS 6200 Series or Cisco UCS 6300 Series FI to IMM, because the Unified Ports hardware characteristics are different.

  • For the migration of Cisco UCS-FI-6332-16UP to Cisco UCS 6536, all SFP+ Ports configuration is ignored, and all QSFP+ Ports configuration is shifted to the left by 16 ports (port 1/17 on Cisco UCS-FI-6332-16UP becomes port 1/1 on Cisco UCS-FI-6536).


Supported Features for Cloning

Supported Features for Cloning an Intersight account

This section provides the list of UCS Server, Chassis, and Domain Policies and the list of Profiles, Pools, Resources, Settings, and Templates supported for cloning an Intersight account.


Note


  • Cloning of an Intersight account is supported only for configurations in standalone mode and in Intersight Managed Mode.

  • Target devices claimed in the source Intersight account are not moved to the destination Intersight account on cloning.


Table 4. Supported Features for Cloning an Intersight Account

Feature Category

Supported Feature

UCS Server Policy

Adapter Configuration

BIOS

Boot Order

Certificate Management

Device Connector

Drive Security

Note: Supported from IMM Transition Tool, Release 4.0.1 onwards.

Ethernet Adapter

Ethernet Network

Ethernet Network Control

Ethernet Network Group

Ethernet QoS

FC Zoning

Fibre Channel Adapter

Fibre Channel Network

Fibre Channel QoS

Firmware

Note: Supported from IMM Transition Tool, Release 4.0.1 onwards.

IMC Access

IPMI over LAN

iSCSI Adapter

iSCSI Boot

iSCSI Static Target

LAN Connectivity

LDAP

Local User

Network Connectivity

NTP

Persistent Memory

Power

SAN Connectivity

SD Card

Serial over LAN

SMTP

SNMP

SSH

Storage

Syslog

Virtual KVM

Virtual Media

Memory Policy

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

Scrub Policy

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

Server Pool Qualification Policy

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

PCIe Connectivity Policy

Note: Supported in IMM Transition Tool, Release 5.1.4 and later.

ID Mapping Policy

Note: Supported in IMM Transition Tool, Release 5.1.4 and later.

UCS Domain Policy

Flow Control

Link Aggregation

Link Control

Multicast

Port

Switch Control

System QoS

VLAN

VSAN

SNMP

LDAP

Note: Supported in IMM Transition Tool, Release 5.0.3 and later.

AuditD Policy

Note: Supported in IMM Transition Tool, Release 5.1.4 and later.

UCS Chassis Policy

Thermal

SNMP

Pools

IP

IQN

MAC

Resource

UUID

WWNN

WWPN

Profiles

UCS Server Profile

UCS Chassis Profile

UCS Domain Profile

Unified Edge Profile

Note: Supported in IMM Transition Tool, Release 5.1.4 and later.

Templates

UCS Server Profile Template

UCS Domain Profile Template

Note: Supported in IMM Transition Tool, Release 4.2.1 and later.

UCS Chassis Profile Template

Note: Supported in IMM Transition Tool, Release 4.2.1 and later.

vNIC/vHBA Template

Note: Supported in IMM Transition Tool, Release 4.2.1 and later.

Unified Edge Template

Note: Supported in IMM Transition Tool, Release 5.1.4 and later.

Access and Permissions Settings

Users

Note: Cloned only when the "Trim Intersight Settings" option is not set. By default, the object is not cloned.

Groups

Note: Cloned only when the "Trim Intersight Settings" option is not set. By default, the object is not cloned.

Roles

Note: Cloned only when the "Trim Intersight Settings" option is not set. By default, the object is not cloned.

Organizations

Resource Groups

Note: To include the entire domain or individual servers in the resource group, the target must be claimed first. Otherwise, an empty resource group with "custom" membership is created.

System

Path Tags

Note: Supported in IMM Transition Tool, Release 5.1.4 and later.


Note


  • A self-signed certificate is generated and pushed to Intersight while cloning an Intersight account having Certificate Management policy.

  • Any policy containing a password is cloned using an automatically generated password.