Supported Features for Conversion
A. Supported Features for Conversion from UCS Manager/Central to IMM
This section provides a list of features that are supported for conversion in the IMM Transition Tool and a policy mapping between Cisco UCS Manager/Central and Intersight.
![]() Note |
If the UCS Central configuration contains VLAN/VSAN aliasing, the IMM Transition Tool will automatically select one of the aliases when performing the conversion of the vNICs/vHBAs. Please review the resulting configuration carefully to make sure it is appropriate. |
| UCS Manager/ UCS Central Feature Category | Source UCS Manager/UCS Central Feature Name | Equivalent IMM Policy | |
|---|---|---|---|
| Admin |
Communication Services Note: Sessions/HTTP settings are defined in Intersight Settings. Telnet/SSH settings are not supported. |
SNMP Policy |
|
|
Organizations |
Intersight Organizations |
||
|
Syslog Note: Only supports up to two remote destination servers |
Syslog Policy |
||
|
Time zone Management |
NTP Policy |
||
|
MAC Address Table Aging |
Switch Control Policy |
||
|
VLAN Port Count Optimization |
Switch Control Policy |
||
|
Reserved VLAN Range Note: Supported in IMM Transition Tool, Release 4.0.1 and later. |
Switch Control Policy |
||
|
Inband Profile VLAN Group |
Ethernet Network Group Policy |
||
|
Inband Profile Network |
IMC Access Policy |
||
|
Inband Profile IP Pool Name |
IMC Access Policy |
||
|
FC Uplink Trunking |
VSAN Policy |
||
|
DNS Note: In UCS Manager, it is found under Admin > Communication Management > DNS Management |
Network Connectivity Policy |
||
|
LDAP Authentication Domain Note: Supported in IMM Transition Tool, Release 5.1.1 and later. |
Intersight LDAP Policy and/or Intersight Appliance Authentication Domain
|
||
| Server Policies and Chassis Policies |
BIOS Policy |
BIOS Policy |
|
|
Boot Policy |
Boot Policy iSCSI Static Target Policy |
||
|
Disk Group Policy |
Storage Policy |
||
|
IPMI Access Profile |
IPMI over LAN Policy |
||
|
iSCSI Adapter Policy |
iSCSI Adapter Policy |
||
|
iSCSI Boot Policy |
iSCSI Boot Policy |
||
|
KVM Management Policy |
Virtual KVM Policy |
||
|
Local Disk Config Policy Note: Replaced by Storage Policy. Local Disk Configuration policy supports only Manual creation not the Automatic policy option. |
Storage Policy, SD Card Policy |
||
|
QoS Policy |
Ethernet QoS Policy/ FC QoS Policy |
||
|
Serial over LAN Policy |
Serial over LAN Policy |
||
|
Service Profile |
Server Profile |
||
|
Service Profile Template Note: Only Updating Templates - no support for Initial Templates (though cloning can be achieved) |
Server Profile Template |
||
|
Storage Profile |
Storage Policy |
||
|
Storage Profile - Security Policy Note: Supported in IMM Transition Tool, Release 4.0.1 and later. |
Drive Security |
||
|
vMedia Policy |
Virtual Media Policy |
||
|
vNIC/vHBA Placement Policy Note: The placement is statically mapped to PCIe slots, with the following mapping:
This mapping is static, but can be adjusted in the Transition Settings. For more details, see B. Transition Settings for Conversion section in Default Settings. |
LAN Connectivity Policy/SAN Connectivity Policy |
||
|
Ethernet Adapter Policy |
Ethernet Adapter Policy |
||
|
Flow Control Policy |
Flow Control Policy |
||
|
LACP Policy |
Link Aggregation Policy |
||
|
LAN Connectivity Policy |
LAN Connectivity Policy |
||
|
VMQ Connection Policy |
VMQ |
||
|
usNIC Connection Policy |
usNIC Note: Part of LAN Connectivity policy |
||
|
SRIOV HPN Connection Policy |
SR-IOV |
||
|
Link Protocol Policy |
Switch Control Policy |
||
|
Multicast Policy |
Multicast Policy |
||
|
Network Control Policy |
Ethernet Network Control Policy |
||
|
Fibre Channel Adapter Policy |
Fibre Channel Adapter Policy |
||
|
SAN Connectivity Policy |
SAN Connectivity Policy |
||
|
Storage Connection Policy |
FC Zoning Policy |
||
|
Power Control Policy Power Restore BIOS setting |
Power Policy |
||
|
vNIC Template |
vNIC Template |
||
|
vHBA Template |
vHBA Template |
||
|
— |
Chassis Profile Template Note:Chassis Profile Template is created by using converted power and thermal policies from the global policies section of the UCS Manager. |
||
|
Memory Policy Note: Supported in IMM Transition Tool, Release 5.0.3 and later. |
Memory Policy |
||
|
Scrub Policy Note: Supported in IMM Transition Tool, Release 5.0.3 and later. |
Scrub Policy |
||
|
Server Pool Qualification Policy Note: Supported in IMM Transition Tool, Release 5.0.3 and later. |
Server Pool Qualification Policy |
||
|
MACsec Policy Note: Supported in IMM Transition Tool, Release 5.1.1 and later. |
MACsec Policy |
||
|
Host Firmware Package Policy Note: Supported in IMM Transition Tool, Release 5.1.3 and later. |
Firmware Policy |
||
|
ID Range Access Control Policy
|
ID Mapping Policy |
||
| Pools |
IP Pool |
IP Pool |
|
|
IQN Suffix Pool |
IQN Pool |
||
|
MAC Pools |
MAC Pool |
||
|
WWNN Pool |
WWNN Pool |
||
|
WWPN Pool |
WWPN Pool |
||
|
Server Pool Note: Supported in IMM Transition Tool, Release 1.0.2 and later. |
Resource Pool |
Following table lists the UCS Manager features that are supported for conversion in the IMM Transition Tool.
| UCS Manager Feature Category | Source UCS Manager Feature Name | Equivalent IMM Policy | |
|---|---|---|---|
| Fabric Config
Note: Merged with regular VLANs |
Appliance VLAN |
VLAN Policy |
|
| QoS System Class |
System QoS Policy |
||
|
VLAN Group Note: IMM Transition Tool, Release 4.1.2 supports VIC QinQ Tunneling |
Ethernet Network Group Policy |
||
|
VLAN |
VLAN Policy |
||
|
VSAN |
VSAN Policy |
||
|
Storage VSAN Note: Supported in IMM Transition Tool, Release 1.0.2 and later. |
VSAN Policy |
||
|
LAN/SAN Pin Group Note:
|
LAN/SAN Pin Group |
||
| Fabric Policies
Note: Merged with regular Network Control Policies |
Appliance Network Control Policy |
Ethernet Network Control Policy |
|
|
UDLD Link Policy |
Link Control Policy |
||
|
Fabric Interconnect Audit Logs
|
AuditD Policy |
||
| Port Roles |
Appliance Port |
Port Policy |
|
|
Appliance Port-Channel |
Port Policy |
||
|
FCoE Uplink Port |
Port Policy |
||
|
FCoE Uplink Port-Channel |
Port Policy |
||
|
LAN Uplink Port |
Port Policy |
||
|
LAN Uplink Port-Channel |
Port Policy |
||
|
SAN Unified Port |
Port Policy |
||
|
SAN Uplink Port |
Port Policy |
||
|
SAN Uplink Port-Channel |
Port Policy |
||
|
Server Port |
Port Policy |
||
|
FC Storage Port Note: Supported in IMM Transition Tool, Release 1.0.2 and later. |
Port Policy |
||
|
SAN Storage Port Note: Supported in IMM Transition Tool, Release 1.0.2 and later. |
Port Policy |
||
|
Breakout Port Note:
|
Port Policy |
B. Fabric Interconnect (FI) Mapping for Conversion
When a Port policy is converted from UCSM to IMM, the port configuration of that policy is adjusted by mapping the unsupported FI (Cisco UCS 6200 and 6300 Series) as shown below:
| UCSM FI | Equivalent IMM FI |
|---|---|
| Cisco UCS-FI-6664 |
Cisco UCS-FI-6664 Note: Supported in IMM Transition Tool, Release 5.1.2 and later. |
| Cisco UCSX-S9108-100G |
Cisco UCSX-S9108-100G Note: Supported in IMM Transition Tool, Release 4.2.2 and later. |
| Cisco UCS-FI-6536 | Cisco UCS-FI-6536 |
| Cisco UCS-FI-64108 | Cisco UCS-FI-64108 |
| Cisco UCS-FI-6454 | Cisco UCS-FI-6454 |
| Cisco UCS-FI-6332-16UP | Cisco UCS-FI-6536 |
| Cisco UCS-FI-6332 | Cisco UCS-FI-6536 |
| UCS-FI-M-6324 |
Cisco UCS-FI-6454 Note: Supported in IMM Transition Tool, Release 4.2.1 and earlier. |
|
Cisco UCSX-S9108-100G Note: Supported in IMM Transition Tool, Release 4.2.2 and later. |
|
| Cisco UCS-FI-6296UP | Cisco UCS-FI-64108 |
| Cisco UCS-FI-6248UP | Cisco UCS-FI-6454 |
![]() Note |
|

Feedback