Technical Specifications
The most current technical specifications for the IE 3x00 series switches can be found in the data sheets:
Additional specifications and details not in the data sheets are in this section.
Enclosure Specifications
Industrial Automation and Hazardous Locations |
Substation |
Traffic Signal |
|
---|---|---|---|
Enclosure types |
Sealed enclosures For example: NEMA4, NEMA4X, NEMA12, NEMA13, IP54, and IP66. |
Vented enclosures For example: NEMA1, IP20, and IP21. |
Fan or blower-equipped enclosures For example: NEMA TS-2. Note: The minimum airflow is 150 lfm1. |
Current and Input Voltage Ratings
Model |
Voltage Range |
@Max Amps |
PoE / PoE (+) budget |
---|---|---|---|
IE-3200-8T2S |
12-48Vdc |
2.2A |
N/A |
IE-3200-8P2S |
12-54Vdc |
5.5A |
240W |
IE-3300-8T2S |
12-48Vdc |
4.0A |
N/A |
IE-3300-8T2X |
12-48Vdc |
4.0A |
N/A |
IE-3300-8U2X |
12-54Vdc |
10.6A |
480W |
IE-3300-8P2S |
12-54Vdc |
10.6A |
240W (base), 360W (with module) |
IE-3400-8T2S |
12-48Vdc |
4.4A |
N/A |
IE-3400-8P2S |
12-54Vdc |
10.7A |
240W (base), 480W (with expansion module) |
Alarm Ratings
Alarm Ratings |
Specification |
---|---|
Alarm input electrical specification |
Senses an external dry contact. The open circuit voltage between any alarm input (1 to 4) and alarm input common is 3.3 VDC. The loop current is 3 mA max per input. The alarm input’s low-level input voltage threshold is 0.4V. Do not apply external power to the alarm input. |
Alarm output electrical specification |
1.0 A @ 24 VDC or 0.5 A @ 48 VDC |