System Specifications

Environmental Specifications

Environment

Specification

Temperature

Ambient operating temperature

32 to 131°F (0 to 55°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Relative humidity

Nonoperating

5 to 85%

Altitude

Operating

0 to 6562 feet (0 to 2,000 meters)

Switch Dimensions

Switch

Width

Depth

Height

Cisco Nexus 93108TC-FX3P

17.2 inches (43.68 cm)

Without fans or PSUs - 18 inches (45.73 cm)

With fans - 19.4 inches (49.28 cm)

With PSUs - 21.1 inches (53.47 cm)

1.72 inches (4.37 cm) (1 RU)

Switch and Module Weights and Quantities

Component

Weight per Unit

Quantity

Cisco Nexus 93108TC-FX3P Chassis (N9K-C93108TC-FX3P)

Without fans or PSUs - 16 lb (7.26 kg)

With fans and PSUs - 23 lb (10.43 kg)

1

Fan Module

– Port-side exhaust (blue) (NXA-FAN-35CFM-PE)

– Port-side intake (burgundy) (NXA-FAN-35CFM-PI)

0.26 lb (0.12 kg)

4

Power Supplies

– 715-W DC port-side intake (burgundy) (NXA-PDC-715W-PI)

– 1100-W AC port-side exhaust (blue) (NXA-PAC-1100W-PE)

– 1100-W AC port-side intake (burgundy) (NXA-PAC-1100W-PI)

– 1900-W AC port-side intake (burgundy) (NXA-PAC-1900W-PI)

3 lb (1.36 kg)

3 lb (1.36 kg)

3 lb (1.36 kg)

3.6 lb (1.63 kg)

2 (1 for operations and 1 for redundancy)

Switch Power Input Requirements

This table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions.


Note


Some power supplies have capabilities that are greater than the maximum power requirements for a switch. To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed here.



Note


If you want to use optics that consume 5W or more power on all the 36 ports, you must install 1100W power supplies.


Switch Typical Power Consumption (AC or DC) Maximum Power Consumption (AC or DC) Heat Dissipation Requirement

Cisco Nexus 93108TC-FX3P

500 W

600 W

2047.285 BTUs per hour

Power Specifications

Power specifications include the specifications for each type of power supply module.

715-W DC Power Supply Specifications

Property Specification

Power

715 W

DC Range

-51V to 57V

Input current

5 A at 240 Vdc and 50 Hz

Frequency

40 to 100 Hz

Efficiency

83% to 89% (20% to 50% load)

Redundancy Modes

Combined, n+1, and n+n

RoHS Compliance

Yes

Form factor

RSP1

1100-W AC Power Supply Specifications

These specifications apply to all versions of the NXA-PAC-1100W power supply.

Characteristic Specification

AC input voltage

Nominal range: 100 and 240 VAC (Range: 90-132 VAC, 180-264 VAC)

AC input frequency

Nominal range: 50 to 60 Hz (Range: 47-63 Hz)

Maximum AC input current

13 A at 100 VAC

6 A at 240 VAC

Maximum input volt-amperes

1300 VA at 100 VAC

Maximum output power per power supply

1100 W

Maximum inrush current

33 A

Maximum hold-up time

12 ms at 1100 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP1

1900-W AC Power Supply Specifications

These specifications apply to all versions of the NXA-PAC-1900W power supply

Property Specification

Power

1900 W

Input Voltage

115 VAC - 120 VAC, 200 VAC - 240 VAC

Input Frequency

Nominal range: 50 to 60 Hz (Range: 47-63 Hz)

Maximum input current

16 A at 115 - 120 VAC

12 A at 200 - 240 VAC

Maximum input volt-amperes

2,400 VA at 200 VAC

Maximum output power per power supply

1900 W

Maximum inrush current

48 A

Maximum hold-up time / ride-through

20ms at 1900 W

Power supply output voltage

(-) 56VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Power Cable Specifications

These sections show the power cables that you can order and use with this switch.

Power Cable Specifications for AC Power Supplies

Power Type Power Cord Part Number Cord Set Description

CAB-C13-C14-2M

Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m)

CAB-C13-CBN

Cabinet jumper power cord, 250 VAC, 10 A, C14-C13 connectors, 2.3 feet (0.7 m)

Argentina

CAB-250V-10A-AR

250 V, 10 A, 8.2 feet (2.5 m)

Australia

CAB-9K10A-AU

250 VAC, 10 A, 3112 plug, 8.2 feet (2.5 m)

Brazil

CAB-250V-10A-BR

250 V, 10 A, 6.9 feet (2.1 m)

European Union

CAB-9K10A-EU

250 VAC, 10 A, CEE 7/7 plug, 8.2 feet (2.5 m)

India

CAB-IND-10A

10 A, 8.2 feet (2.5 m)

India

CAB-C13-C14-2M-IN

Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m)

India

CAB-C13-C14-3M-IN

Power Cord Jumper, C13-C14 Connectors, 9.8 feet (3.0 m)

Israel

CAB-250V-10A-IS

250 V, 10 A, 8.2 feet (2.5 m)

Italy

CAB-9K10A-IT

250 VAC, 10 A, CEI 23-16/VII plug, 8.2 feet (2.5 m)

Japan

CAB-C13-C14-2M-JP

Power Cord Jumper, C13-C14 Connectors, 6.6 feet (2.0 m)

North America

CAB-9K12A-NA

125 VAC, 13 A, NEMA 5-15 plug, 8.2 feet (2.5 m)

North America

CAB-AC-L620-C13

NEMA L6-20-C13, 6.6 feet (2.0 m)

North America

CAB-N5K6A-NA

200/240V, 6A, 8.2 feet (2.5 m)

Peoples Republic of China

CAB-250V-10A-CN

250 V, 10 A, 8.2 feet (2.5 m)

South Africa

CAB-250V-10A-ID

250 V, 10 A, 8.2 feet (2.5 m)

Switzerland

CAB-9K10A-SW

250 VAC, 10 A, MP232 plug, 8.2 feet (2.5 m)

United Kingdom

CAB-9K10A-UK

250 VAC, 10 A, BS1363 plug (13 A fuse), 8.2 (2.5 m)

All except Argentina, Brazil, and Japan

NO-POWER-CORD

No power cord included with switch

Power Cables for NXA-PAC-1100W Power Supplies

Cable

Description

Illustration

CAB-TA-NA

North America AC Type A Power Cable

CAB-TA-UK

United Kingdom AC Type A Power Cable

CAB-TA-250V-JP

Japan 250V AC Type A Power Cable

CAB-TA-EU

Europe AC Type A Power Cable

CAB-C15-CBN

Cabinet Jumper Power Cord, 250 VAC 13A, C14-C15 Connectors

CAB-ACBZ-12A

AC Power Cord (Brazil) 12A/125V BR-3-20 plug up to 12A

CAB-TA-IN

India AC Type A Power Cable

CAB-TA-IS

Israel AC Type A Power Cable

DC Power Cable Specifications

Part ID Number

Description

Photo

NXA-PDC-2KW-PE/PI The 2000W DC power supply (NXA-PDC-2KW-PE/PI) is not shipped with a connector. You must purchase the cable (PWR-2KW-DC-CBL) separately.

Regulatory Standards Compliance Specifications

This table lists the regulatory standards compliance for the switch.

Table 1. Regulatory Standards Compliance: Safety and EMC

Specification

Description

Regulatory compliance

Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC.

Safety

  • CAN/CSA-C22.2 No. 60950-1 Second Edition

  • CAN/CSA-C22.2 No. 62368-1-19 Third Edition

  • ANSI/UL 60950-1 Second edition

  • IEC 62368-1

  • EN 62368-1

  • AS/NZS 62368-1

  • GB4943

  • UL 62368-1

EMC: Emissions

  • 47CFR Part 15 (CFR 47) Class A

  • AS/NZS CISPR22 Class A

  • CISPR22 Class A

  • EN55022 Class A

  • ICES003 Class A

  • VCCI Class A

  • EN61000-3-2

  • EN61000-3-3

  • KN22 Class A

  • CNS13438 Class A

EMC: Immunity

  • EN55024

  • CISPR24

  • EN300386

  • KN 61000-4 series

RoHS