Cisco Nexus Fabric Extender
|
|
|
N2K-PAC-200W |
N2200-PAC-400W (Blue) N2200-PAC-400W-B (Red) |
N2200-PDC-400W (Blue) N2200-PDC-350W-B |
NXA-PHV-500W (Blue) NXA-PHV-500W-B (Red) |
FEXs |
Cisco Nexus 2148T |
Cisco Nexus 2332TQ, 2348TQ, 2348TQ-E, and 2348UPQ, Cisco Nexus 2248TP-E, 2248TP, 2232PP, 2224TP, 2248PQ, 2232TM, 2232TM-E |
Cisco Nexus 2332TQ, 2348TQ, 2348TQ-E, and 2348UPQ, Cisco Nexus 2248TP-E, 2248TP, 2232PP, 2224TP, 2248PQ, 2232TM, 2232TM-E Note The 2232TM and 2232TM-E do not support the N2200-PDC-350W-B |
Cisco Nexus 2332TQ, 2348TQ, and 2348UPQ, Cisco Nexus 2248TP-E, 2248TP, 2232PP, 2232TM, 2232TM-E |
Typical and Maximum Input Operating Power |
165 W |
190W @ 30m, 250W maximum (Cisco Nexus 2332TQ) 280W @ 30m, 350W maximum (Cisco Nexus 2348TQ and 2348TQ-E) 125W, 200W maximum (Cisco Nexus 2348UPQ) 110W, 130W maximum (Cisco Nexus 2248TP-E and 2248TP) 270W (Cisco Nexus 2232PP) 85W, 100W maximum (Cisco Nexus 2224TP) 350W, 386W maximum (Cisco Nexus 2232TM) |
Maximum Output Power |
200 W |
400 W |
400W, 350 W |
500W |
Input Voltage |
90 to 264 VAC |
90 to 264 VAC |
–40 to –72 VDC |
192 to 400 VDC, 90 to 295 VAC |
Frequency |
50 to 60 Hz |
50 to 60 Hz |
N/A |
50 to 60 Hz |
Input Current |
1.5 A/2.2 A* (typical/maximum) * The Input currents listed for 110 V; divide by two for 220 V |
Cisco Nexus 2332TQ: 1.4 A/2.3 A* (typical/maximum) Cisco Nexus 2348TQ and 2348TQ-E: 2.5 A/3.2 A* (typical/maximum) Cisco Nexus 2348UPQ: 1.2 A/1.8 A* (typical/maximum) Cisco Nexus 2248TP-E and 2248TP: 1.0 A/1.2 A* (typical/maximum) Cisco Nexus 2232PP: 2.5 A* (typical) Cisco Nexus 2224TP: 0.7 A/0.9 A* (typical/maximum) Cisco Nexus 2232TM 3.2 A/3.5 A* (typical/maximum) * Input currents listed for 110 V; divide by two for 220 V |
Cisco Nexus 2332TQ: 3.8 A/6.2 A* (typical/maximum) Cisco Nexus 2348TQ and 2348TQ-E: 7.0 A/8.7 A* (typical/maximum) Cisco Nexus 2348UPQ: 3.1 A/5.0 A* (typical/maximum) Cisco Nexus 2248TP-E and 2248TP: 2.8 A/3.3 A* (typical/maximum) Cisco Nexus 2232PP: 7.0 A* (typical) Cisco Nexus 2224TP: 2.1 A/2.5 A* (typical/maximum) Cisco Nexus 2232TM 8.8 A/9.6 A* (typical/maximum) * Input currents listed for -40 VDC |
Cisco Nexus 2332TQ: 0.6 A/1.1 A* (typical/maximum) Cisco Nexus 2348TQ: 1.2 A/1.5 A* (typical/maximum) Cisco Nexus 2348UPQ: 0.5 A/0.8 A* (typical/maximum) Cisco Nexus 2248TP-E and 2248TP: 0.5 A/0.6 A* (typical/maximum) Cisco Nexus 2232PP: 1.2 A* (typical) Cisco Nexus 2224TP: 0.4 A/0.4 A* (typical/maximum) Cisco Nexus 2232TM 1.4A/1.6 A* (typical/maximum) * Input currents listed for 240 VDC and 277 VAC; divide by 1.6 for 380 VDC |
Efficiency |
84% typical |
88% to 92% (50% to 100% load) |
85% to 88% (50% to 100% load) |
91% to 94% (50% to 100% load) |
RoHS Compliance |
RoHS-5 compliant |
RoHS-6 compliant |
RoHS-6 compliant |
RoHS-6 compliant |
Hot Swappable |
Yes |
Yes |
Yes |
Yes |
Heat Dissipation |
560/680 BTU/hr (typical/maximum) |
Cisco Nexus 2332TQ: 510/850 BTU/hour (typical/maximum) Cisco Nexus 2348TQ and 2348TQ-E: 952/1190 BTU/hour (typical/maximum) Cisco Nexus 2348UPQ: 425/680 BTU/hour (typical/maximum) Cisco Nexus 2248TP-E and 2248TP: 374/442 BTU/hour (typical/maximum) Cisco Nexus 2232PP: 918BTU/hour (typical) Cisco Nexus 2224TP: 289/340 BTU/hour (typical/maximum) Cisco Nexus 2232TM: 1190/1312 BTU/hour (typical/maximum) |
Power Cord Rating |
3 A@100 Vin, 1.5 A@240 Vin |
6 A@100 Vin, 3 A@240 Vin |
15A@-48Vin, 8A@-60Vin |
4A @ 240Vin and 277Vin, 3A@ 380 Vin |
Cubic Inches |
51 in^3 |
39 in^3 |
39 in^3 |
39 in^3 |
Power Density |
3.9 W/in^3 |
10.2 W/in^3 |
10.2 W/in^3 |
10.2 W/in^3 |
Operating Temperature |
50°C |
50°C |
50°C |
50°C |
Cooling |
Internal fans to cool the supply |
Internal fans to cool the supply |
Internal fans to cool the supply |
Internal fans to cool the supply |
Input connector |
AC connector in the power supply face |
AC connector in the power supply face |
DC connector in the power supply face |
HVAC + HVDC connector in the power supply face |
Output connector |
DC output connector in the back |
DC output connector in the back |
DC output connector in the back |
DC output connector in the back |
Supply Indicators |
Supply Health: Green indicates the power supply is operational and red indicates a fault. AC good indicator: Solid green indicates that AC is present and is within the supply specifications. |
Supply Health: Green indicates the power supply is operational and amber indicates a fault. AC good indicator: Solid green indicates that AC is present and is within the supply specifications. |
Supply Health: Green indicates the power supply is operational and amber indicates a fault. |
Supply Health: Green indicates the power supply is operational and amber indicates a fault. |