Server Specifications

Server Specifications

This appendix lists the physical, environmental, and power specifications for the server.

Physical Specifications

The table lists the physical specifications for the server versions.

Table 1. Physical Specifications

Description

Specification

Height

1.7 in. (43.2 mm)

Width

16.9 in. (429.0 mm)

Depth (length)

Server only: 29.5 in. (740.3 mm)

Server with slide rail: 31.0 in (787.4 mm)

Weight

Maximum: 37.5 lb. (17.0 Kg)

Minimum: 29.0 lb. (13.2 Kg)

Environmental Specifications

The table lists the environmental requirements and specifications for the server.

Table 2. Physical Specifications

Description

Specification

Temperature, Operating

10° C to 35° C (50° F to 95° F) with no direct sunlight

Derate the maximum temperature by 1°C per every 300 meters of altitude above sea level.

Note

 

Although the ASHRAE guidelines define multiple classes with different operating ranges, the recommended temperature and humidity operating range is the same for each class. The recommended temperature and humidity ranges are:

  • Operating Temperature: 64.4°F to 80.6°F (18°C to 27°C)

For general information, see the Cisco Unified Computing System Site Planning Guide: Data Center Power and Cooling.

Temperature, non-operating

(when the server is stored or transported)

Below -40° C or above 65° C (below -40° F or above 149° F)

Maximum rate of change (operating and non-operating) 20° C/hr (36° F/hr)

Extended Operating Temperature

5° C to 40° C (41° F to 104° F) with no direct sunlight

Maximum allowable operating temperature derated

1° C/175 m (1° F/319 ft) above 950 m (3117 ft)

5° C to 45° C (41° F to 113° F) with no direct sunlight

Maximum allowable operating temperature derated

1° C/125 m (1° F/228 ft) above 950 m (3117 ft)

System performance may be impacted when operating in the extended operating temperature range.

Operation above 40° C is limited to less than 1% of annual operating hours.

Hardware configuration limits apply to extended operating temperature range.

Humidity (RH), operating

8 to 90% and 24° C (75o F) maximum dew-point temperature, non-condensing environment

Humidity (RH), non-operating

(when the server is stored or transported)

Below 5% or above 95% and 33o C (91o F) maximum dew-point temperature, non-condensing environment

Altitude, operating

0 to 10,000 feet

Altitude, non-operating

(when the server is stored or transported)

0 to 40,000 feet

Sound power level

Measure A-weighted per ISO7779 LwAd (Bels)

Operation at 73°F (23°C)

5.8

Sound pressure level

Measure A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

43

Network Virtual Interface Card Considerations

This section describes network virtual interface card (VIC) support and considerations for the Cisco Application Policy Infrastructure Controller (APIC) APIC G5 Server.

This supported virtual interface card must be inserted to PCIe Riser 01 for Cisco APIC G5 Server.

  • APIC-G5 Cisco VIC 15425


Note


50G optics are not supported on APIC-G5 Cisco VIC 15425. Only 10G and 25G variants are supported for connections from APIC-G5 Cisco VIC 15425 to a leaf switch.


Please see the list of transceiver options: https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/transceiver-modules/datasheet-c78-736950.html.

See CIMC NIC Mode and NIC Redundancy Settings for additional considerations and more information on NIC modes.

Power Specifications

Table 3. G5 System Load Estimates

System Workload Factor

50%

75%

100%

Maximum Input Power

409.91 W

409.91 W

409.91 W

Input Power

268.24 W

338.59 W

409.91 W

Idle Input Power

129.18 W

129.18 W

129.18 W

Input Current

1.13 A

1.43 A

1.72 A

Air Flow

31.69 cfm

40 cfm

48.43 cfm

Cooling

915.28 BTU/hr.

1155.31 BTU/hr.

1398.68 BTU/hr.

Table 4. G5 System Load Estimates

System Workload Factor

50%

75%

100%

Maximum Input Power

429.85 W

429.85 W

429.85 W

Input Power

280.83 W

355 W

429.85 W

Idle Input Power

134.26 W

134.26 W

134.26 W

Input Current

1.19 A

1.5 A

1.81 A

Air Flow

33.18 cfm

41.94 cfm

50.78 cfm

Cooling

958.22 BTU/hr.

1211.31 BTU/hr.

1466.71 BTU/hr.


Note


Do not mix power supply types or wattages in the server. Both power supplies must be identical.

You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:

https://ucspowercalculator.cisco.com

The power specifications for the supported power supply options are listed in these sections.

1050 W DC Power Supply

This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-

PSUV21050D-D).

Table 5. 1050 W DC Specifications

Description

Specification

Input Connector

Molex 42820

Input Voltage Range (V rms)

-48

Maximum Allowable Input Voltage Range (V rms)

-40 to -72

Frequency Range (Hz)

NA

Maximum Allowable Frequency Range (Hz)

NA

Maximum Rated Output (W)

1050 W

Maximum Rated Standby Output (W)

36

Nominal Input Voltage (V rms)

-48

Nominal Input Current (A rms)

24

Maximum Input at Nominal Input Voltage (W)

1154

Maximum Input at Nominal Input Voltage (VA)

1154

Minimum Rated Efficiency (%)1

91

Minimum Rated Power Factor1

NA

Maximum Inrush Current (A peak)

15

Maximum Inrush Current (ms)

0.2

Minimum Ride-Through Time (ms)2

5


Note


  1. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published at http://www.80plus.org/ for certified values.

  2. Time output voltage remains within regulation limits at 100% load, during input voltage dropout.


1200 W AC Power Supply

This section lists the specifications for each 1200 W AC Titanium Power Supply for C-series Rack Servers (Cisco part number UCSC-PSU1-1200W-D).

Table 6. 1050 W DC Specifications

Description

Specification

Input Connector

IEC320 C14

Input Voltage Range (V rms)

100 to 240

Maximum Allowable Input Voltage Range (V rms)

90 to 264

Frequency Range (Hz)

50 to 60

Maximum Allowable Frequency Range (Hz)

47 to 63

Maximum Rated Output (W)1

1100 W | 1200 W

Maximum Rated Standby Output (W)

48

Nominal Input Voltage (V rms)

100 | 120 | 208 | 230

Nominal Input Current (A rms)

12.97 | 10.62 | 6.47 | 5.84

Maximum Input at Nominal Input Voltage (W)

1300 | 1264 | 1343 | 1340

Maximum Input at Nominal Input Voltage (VA)

1300 | 1266 | 1345 | 1342

Minimum Rated Efficiency (%)2

90 | 90 | 91 | 91

Minimum Rated Power Factor2

0.97 | 0.97 | 0.97 | 0.97

Maximum Inrush Current (A peak)

20

Maximum Inrush Current (ms)

0.2

Minimum Ride-Through Time (ms)3

12


Note


  1. Maximum rated output is limited to 1100W when operating at low-line input voltage (100-127V).

  2. This is the minimum rating required to achieve 80 PLUS Titanium certification, see test reports published at http://www.80plus.org/ for certified values.

  3. Time output voltage remains within regulation limits at 100% load, during input voltage dropout.


Power Cord Specifications

Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.


Note


Only the approved power cords or jumper power cords listed below are supported.


Table 7. Supported Power Cords

Description

Length (Feet)

Length (Meters)

CAB-48DC-40A-8AWG

DC power cord, -48 VDC, 40 A, 8 AWG

Three-socket Mini-Fit connector to three-wire

11.7

3.5

CAB-C13-C14-AC

AC power cord, 10 A; C13 to C14, recessed receptacle

9.8

3.0

CAB-250V-10A-AR

AC power cord, 250 V, 10 A

Argentina

8.2

2.5

CAB-C13-C14-2M-JP

AC Power Cord, C13 to C14

Japan PSE Mark

6.6

2.0

CAB-9K10A-EU

AC Power Cord, 250 V, 10 A; CEE 7/7 Plug

Europe

8.2

2.5

CAB-250V-10A-IS

AC Power Cord, 250 V, 10 A

Israel

8.2

2.5

CAB-250V-10A-CN

AC power cord, 250 V, 10 A

PR China

8.2

2.5

CAB-ACTW

AC power cord, 250 V, 10 A

Taiwan

7.5

2.3

CAB-C13-CBN

AC cabinet jumper power cord, 250, 10 A,

C13 to C14

2.2

0.68

CAB-C13-C14-2M

AC cabinet jumper power cord, 250 V, 10 A,

C13 to C14

6.6

2.0

CAB-9K10A-AU

AC power cord, 250 V, 10 A, 3112 plug,

Australia

8.2

2.5

CAB-N5K6A-NA

AC power cord, 200/240 V, 6 A,

North America

8.2

2.5

CAB-250V-10A-ID

AC power Cord, 250 V, 10 A,

India

8.2

2.5

CAB-9K10A-SW

AC power cord, 250 V, 10 A, MP232 plug

Switzerland

8.2

2.5

CAB-250V-10A-BR

AC power Cord, 250 V, 10 A

Brazil

8.2

2.5

CAB-9K10A-UK

AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug

United Kingdom

8.2

2.5

CAB-9K12A-NA

AC power cord, 125 V, 13 A, NEMA 5-15 plug

North America

8.2

2.5

CAB-AC-L620-C13

AC power cord, NEMA L6-20 to C13 connectors

6.6

2.0

CAB-9K10A-IT

AC power cord, 250 V, 10 A, CEI 23-16/VII plug

Italy

8.2

2.5

R2XX-DMYMPWRCORD

No power cord; PID option for ordering server with no power cord

NA

NA