- Preface
- Cisco ONS Documentation Roadmap for Release 10.x.x
- New and Changed Information for Release 10.x.x
- Chapter 1, Overview
- Chapter 2, Provisioning Procedures
- Chapter 3, ACT Commands
- Chapter 4, ALW Commands
- Chapter 5, APPLY Commands
- Chapter 6, CANC Commands and Messages
- Chapter 7, CHG Commands
- Chapter 8, CLR Commands
- Chapter 9, CONN Commands
- Chapter 10, COPY Commands
- Chapter 11, DISC Commands
- Chapter 12, DLT Commands
- Chapter 13, ED Commands
- Chapter 14, ENT Commands
- Chapter 15, EX Commands
- Chapter 16, INH Commands
- Chapter 17, INIT Commands
- Chapter 18, OPR Commands
- Chapter 19, REPT Commands
- Chapter 20, RLS Commands
- Chapter 21, RMV Commands
- Chapter 22, RST Commands
- Chapter 23, RTRV Commands
- Chapter 24, SCHED Commands
- Chapter 25, SET Commands
- Chapter 26, SW Commands
- Chapter 27, TST Commands
- Chapter 28, Access Identifiers
- Chapter 29, Conditions
- Chapter 30, Modifiers
- Chapter 31, TL1 Errors
- 14.3 ENT-ALMTYPE
- 14.4 ENT-AUTO
- 14.5 ENT-AWCFG
- 14.7 ENT-BWP-ETH
- 14.8 ENT-CPS
- 14.10 ENT-CRS-ETH
- 14.11 ENT-EQPT
- 14.14 ENT-FOG
- 14.15 ENT-FTPSERVER
- 14.16 ENT-LMP -CTRL
- 14.17 ENT-LMP-DLINK
- 14.18 ENT-LMP-TLINK
- 14.19 ENT-LNK
- 14.20 ENT-LNKTERM
- 14.21 ENT-MA-CFM
- 14.22 ENT-MD-CFM
- 14.23 ENT-MDMAMAP-CFM
- 14.24 ENT-MEP-CFM
- 14.25 ENT-MIP-CFM
- 14.26 ENT-NNI-ETH
- 14.27 ENT-NNI-CHGRP
- 14.28 ENT-OCHCC
- 14.29 ENT-OCHNC
- 14.30 ENT-OPMODE
- 14.31 ENT-QNQ-CHGRP
- 14.32 ENT-QNQ-ETH
- 14.33 ENT-REP
- 14.36 ENT-ROUTE
- 14.37 ENT-ROUTE-GRE
- 14.38 ENT-TADRMAP
- 14.39 ENT-TRAPTABLE
- 14.40 ENT-TUNNEL-FIREWALL
- 14.41 ENT-TUNNEL-PROXY
- 14.42 ENT-UNICFG
- 14.43 ENT-USER-SECU
- 14.44 ENT-VCG
- 14.45 ENT-VLAN
- 14.46 ENT-WDMANS
- 14.47 ENT-WDMSIDE
ENT Commands
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This chapter provides enter (ENT) commands for the Cisco ONS 15454, Cisco ONS 15454 M2, and Cisco ONS 15454 M6.
Note All commands supported on the Cisco ONS 15454 platform are also supported on Cisco ONS 15454 M2 and Cisco ONS 15454 M6 platforms.
14.1 ENT-<MOD1PAYLOAD>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter 10GFC, 10GIGE, 40GIGE, 100GIGE, 1GFC, 1GFICON, 2GFC, 4GFC, 2GFICON, 5GIB, 8GFC, CHGRP, D1VIDEO, DV6000, DVBASI, EC1, ESCON, ETRCLO, FSTE, GIGE, HDTV, ISC1, ISCCOMPAT, ISC3PEER2R, ISC3PEER1G, ISC3PEER2G, OC-12, OC-192, OC-3, OC-48, OC768, OTU1, OTU2, OTU3, OTU4, or T3 (ENT-<MOD1PAYLOAD> command creates a specified port.
Usage Guidelines
- Supports 3GVIDEO, SDSDI, HDSDI, ISC3STP1G, ISC3STP2G modifiers.
- When 1GFICON and 2GFICON payloads are provisioned, distance extension=B2B is the default and only valid setting. Setting distance extension (using ED-1GFICON or ED-2GFICON) to any other setting will be denied with the error message "Provisioning Rules Failed."
- Support is limited to ports with pluggable port modules (PPMs) and any operating mode.
- When creating an operating mode for payloads, the trunk ports are auto provisioned.
- See Table 30-1 for supported modifiers by platform.
- NUMOFLANES is the new parameter added for ENT-<MOD1PAYLOAD> command. This parameter is applicable for payload provisioning on CFP-LC card only. The possible values are 1 and 4. Depending on the values mentioned, the card provisions 1 or 4 number of sublanes for CFP ports.
- No payloads can be provisioned in RGN-100G opmode between two 100G-LC-C Cards.
Category
Security
Input Format
ENT-<MOD1PAYLOAD>:[<TID>]:<AID>:<CTAG>[:::NUMOFLANES=<NUMOFLANES>:];
Input Example
Input Parameters
Access identifier from the “FACILITY” section. AR-MXP, AR-XP, and AR-XPE cards use the VFAC AID. |
|
Identifies the type of pluggable provisioned on the CFP-LC card based on number of lanes provisioned. The value can be 1 or 4. |
14.2 ENT-<MOD_RING>
(Cisco ONS 15454) The Enter Bidirectional Line Switched Ring (ENT-<MOD_RING>) command creates either a two-fiber or four-fiber BLSR.
Usage Guidelines
The command parameters that are used vary depending on whether a two-fiber or four-fiber BLSR is being created.
Here is an example of a command to create a four-fiber BLSR:
ENT-BLSR:TID:BLSR-N02ABC:CTAG:::RINGID=N02ABC,NODEID=3,MODE=4F,RVRTV=Y,
RVTM=5.0,SRVRTV=Y,SRVTM=5.0,EASTWORK=FAC-5-1,WESTWORK=FAC-6-1,
EASTPROT=FAC-12-1,WESTPROT=FAC-13-1;
Here is an example of a command to create a two-fiber BLSR:
ENT-BLSR:TID:BLSR-N04EFG:CTAG:::RINGID=N04EFG,NODEID=6,MODE=2F,RVRTV=Y,
RVTM=5.0,EASTWORK=FAC-5-1,WESTWORK=FAC-6-1;
The following actions will produce error messages:
- If RINGID is different from the string presented in the AID format, an IIAC (RingId Does Not Match With AID) error message is returned.
- Sending this command to create a BLSR with an out-of-range node ID or ring ID will return an IIAC (Invalid NodeId) or (Invalid RingId) error message.
- Sending this command to create a four-fiber BLSR on OC-12 cards, or a two-fiber BLSR on OC-3 cards will return an IIAC (Input, Invalid Work/Prot Port) error message.
- Sending this command to create a BLSR on a network element (NE) that already has five BLSRs will return a SRQN (BLSR Creation Failed) error message because only one NE can support up to five BLSRs.
- Sending this command to create a BLSR on a port with 1+1 protection will return a SRQN (BLSR Creation Failed) error message.
- If the system fails while accessing the IOR, an SROF (Get IOR Failed) error message is returned.
- If the AID is invalid, an IIAC (Invalid AID) error message is returned.
- If any facility requested in this command is in use, a SPLD (Facility is Busy) error message is returned.
- The SRQN (BLSR Creation Failed) error message is returned for an invalid creation query.
- Sending this command to provision the mode with an invalid BLSR mode will return an IIDT (Invalid BLSR Mode) error message.
- Sending this command to modify SRVRTV or SRVTM on the two-fiber BLSR will return an IDNV (Invalid Data for 2F-BLSR) error message.
- Sending this command to provision the node ID with invalid data will return an IIAC (Invalid NodeId) error message.
- Sending this command to provision the ring ID with invalid data will return an IIAC (Invalid RingId) error message.
- Sending this command with an invalid working AID will return an IIDT (Invalid BLSR Working Facility) error message.
- Sending this command with an invalid protection AID will return an IIDT (Invalid BLSR Protect Facility) error message.
- Changing the BLSR node ID with a duplicated ID will return an SROF (Cannot Set NodeId) error message.
Note Both <EASTPROT> and <WESTPROT> are optional, but required for 4-fiber BLSR creation.
Note The ALL AID is invalid for this command.
Category
Security
Input Format
ENT-<MOD_RING>:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],NODEID=<NODEID>,
MODE=<MODE>,[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SRVRTV=<SRVRTV>],
[SRVTM=<SRVTM>],EASTWORK=<EASTWORK>,WESTWORK=<WESTWORK>,
[EASTPROT=<EASTPROT>],[WESTPROT=<WESTPROT>];
Input Example
ENT-BLSR:PETALUMA:BLSR-2:123::::::RINGID=2,NODEID=1,MODE=4F,
RVRTV=Y,RVTM=5.0,SRVRTV=Y,SRVTM=5.0,EASTWORK=FAC-5-1,WESTWORK=FAC-6-1,
EASTPROT=FAC-12-1,WESTPROT=FAC-13-1;
ENT-BLSR:PETALUMA:BLSR-2:123:::RINGID=2,NODEID=1,MODE=2F,RVRTV=Y,
RVTM=5.0,EASTWORK=FAC-5-1,WESTWORK=FAC-6-1;
Input Parameters
Access identifier from the “AidUnionId1” section. Identifies the BLSR of the NE. ALL or BLSR-ALL AIDs are not allowed for editing the BLSR. This command only supports a single BLSR AID. |
|
(Optional) The BLSR ID of the NE up to six characters. Valid characters are A-Z and 0-9. RINGID is a string. The parameter defaults to the text in the AID that follows the “BLSR-”. |
|
The BLSR node ID of the NE. NODEID ranges from 0 to 31. NODEID is an integer. |
|
Mode with which the command is to be implemented. Identifies the BLSR mode. The parameter type is BLSR_MODE (BLSR mode). |
|
(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF (disable or enable an attribute). |
|
(Optional) Revertive time. Defaults to 5.0. The parameter type is REVERTIVE_TIME (revertive time). |
|
The span revertive mode for four-fiber BLSR only. Defaults to Y. The parameter type is ON_OFF (disable or enable an attribute) |
|
(Optional) The span revertive time for four-fiber BLSR only. Defaults to 5.0. The parameter type is REVERTIVE_TIME (revertive time). |
|
East working facility. AID from the “FACILITY” section. |
|
West working facility. AID from the “FACILITY” section. |
|
(Optional) East protect facility. AID from the “FACILITY” section. |
|
(Optional) West protect facility. AID from the “FACILITY” section. |
14.3 ENT-ALMTYPE
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Alarm Type (ENT-ALMTYPE) command enters user-defined alarm types on the fly for environmental inputs. In addition to the system-defined alarm types, this command supports up to 50 new user-defined alarm types.
Usage Guidelines
ALMTYPE must not contain blank spaces or special characters other than the hyphen (-). The maximum ALMTYPE length allowed is 20 characters.
Entering of duplicate alarm types is not allowed. System-defined alarm types cannot be replicated as user-defined alarm type.
Category
Security
Input Format
Input Example
Input Parameters
Specifies user-defined alarm types associated with virtual wires in environmental alarm inputs. |
14.4 ENT-AUTO
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) This command creates an AUTO port.
Usage Guidelines
Requires ports with PPMs and any operating mode on that port.
Supports OC3, OC12, OC48, and 1GE line rates based on incoming traffic when auto sense is enabled. Default line rate is OC48.
Category
Security
Input Format
Input Example
Input Parameters
14.5 ENT-AWCFG
(Cisco ONS 15454, Cisco ONS 15454 M2, Cisco ONS 15454 M6) The Enter Alien Wavelength Configuration (ENT-AWCFG) creates alien wavelength configuration.
Usage Guidelines
Category
Security
Input Format
ENT-AWCFG:[<TID>]:<SRC>:<CTAG>:::<ALIENID=ALIENID>,[FECMODE=<FECMOD>],[:];
Input Example
ENT-AWCFG::PCHAN-1-35-TX:1:::ALIENID=CRS-1 40G-DPSK-ITU-T LC,FECMODE=OFF;
|
|
---|---|
AID from the “ALL” section. |
|
Indicates the operating mode for alien wavelength. ALIENID is a STRING. |
|
14.6 ENT-BULKROLL-<OCN_TYPE>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Bulk Roll for OC-12, OC-192, OC-3, OC-48, or OC768 (ENT-BULKROLL-<OCN_TYPE>) command enters information about rolling traffic from one end point to another without interrupting service. This command can be used for line-level rolling and bulk rolling and cannot be used for single-path-level rolling.
Usage Guidelines
Category
Security
Input Format
ENT-BULKROLL-<MOD_PATH>:[<TID>]:<FROM>:<CTAG>:::RTOSTART=<RTOSTART>,
[RFROMSTART=<RFROMSTART>],[RFROMEND=<RFROMEND>],[RMODE=<RMODE>],
[CMDMDE=<CMDMDE>];
Input Example
ENT-BULKROLL-OC-48:CISCO:FAC-5-1:123:::RTOSTART=STS-6-1-1,
RFROMSTART=STS-5-1-1,RFROMEND=STS-5-1-4,RMODE=AUTO,CMDMDE=FRCD;
Input Parameters
One of the endpoints. Access identifier from the “FACILITY” section for line-level rolling and bulk rolling. |
|
The starting time slot in the destination roll port. Access identifier from the “FACILITY” section (synchronous transport signal [STS] or Virtual Tributary [VT]). |
|
The starting time slot in the source roll port. Access identifier from the “FACILITY” section (STS or VT). Defaults to STS-<FROMSLOT>-<FROMPORT>-1, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID. |
|
The ending time slot in the source roll port. Access identifier from the “FACILITY” section (STS and VT). Defaults to STS-<FROMSLOT>-<FROMPORT>-N, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID and N is the value of OCn (for example, with OC-48, n=48). |
|
Indicates the mode of the rolling operation. The parameter type is RMODE (roll mode). |
|
Automatic. When a valid signal is available, the roll with an AUTO mode will automatically delete the previous end-point. |
|
Manual. Enter the corresponding delete roll/bulkroll command to delete the previous end-point. |
|
Command execution mode. Defaults to NORM. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied. |
|
Force the system to override a state where the command would normally be denied. |
|
Execute the command normally. Do not override any conditions that could make the command fail. |
14.7 ENT-BWP-ETH
Enter Bandwidth Profile for ETH command is used to enter a new Bandwidth Profile entry in BWP DB. The BWP DB is a collection of Bandwidth Profiles used in a Network Element.
Usage Guidelines
Category
Security
Input Format
ENT-BWP-ETH:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],[CIR=<CIR>],[CBS=<CBS>],[PBS=<PBS>],[PIR=<PIR>],[CFMSTATE=<CFM_STATE>][:];
Input Example
ENT-BWP-ETH:ROCKS:BWP-10000:1:::NAME="MyBWP",CIR=10,CBS=1M,PBS=1M,PIR=20,CFMSTATE=Y;
Input Parameters
14.8 ENT-CPS
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Control Plane Service (CPS) command creates a control plane service. Specify the source port, destination ports, and the IP address of the destination node.
Usage Guidelines
- If the AID is invalid, an IIAC (invalid AID) error message is returned. The following AIDs are supported:
– CLIENT cps type support FAC and VFAC AID type.
– TRUNK cps type support CHAN AID type.
– ADD cps type support CHAN, PCHAN, and LINEWL AID type.
- The ALL AID is invalid for this command
- No check is performed on destination AIDs. The check is made during the CPS activation by OPR-CPS.
- In case of 1WAY, unidirectional connection, SRC and DST are single AIDs. In case of 2WAY, bidirectional connection, SRC and DST are double AIDs. However, in case of CLIENT or TRUNK cpstype, src and dst are single AID and the connection is of type 2WAY because of bidirectional ports hence this rule is not applicable.
- If the RESTTYPE is REVERT, it is required to set the REVERTMODE and SOAK parameters.
- If the RESTTYPE is REVERT, it is mandatory to set the REVERTMODE parameter as MANUAL or AUTO.
- SOAK time is mandatory if the REVERTMODE parameter is set to MANUAL or AUTO.
Category
Security
Input Format
ENT-CPS[:<TID>]:<SRC>:<CTAG>::<DSTADDR>,<DST>,[<WCT>],<CPSTYPE>[:CKTID=<CKTID>],[VALMODE=<VALMODE>],[VALZONE=<VALZONE>],[VALMODESEC=<VALMODESEC>],[VALZONESEC=<VALZONESEC>],[RESTTYPE=<RESTTYPE>],[REVERTMODE=<REVERTMODE>],[SOAK=<HH-MM-SS>],>],[CKTLABEL=<CKTLABEL>],[FREQ=<FREQ>],[WIDTH=<WIDTH>],[CKTPRIORITY=<CKTPRIORITY>],[ALLOWRGN=<ALLOWRGN>],[PATHPOLICY=<PATHPOLICY>],[DSPWROFS=<DSPWROFS>],[USPWROFS=<USPWROFS>[:];
Input Example
ENT-CPS::CHAN-1-15-10-RX&CHAN-1-14-10-TX:8::10.20.30.40,CHAN-10-1-10-TX&CHAN-10-1-10-RX,2WAY,ADD::;
ENT-CPS::FAC-1-5-1:888::10.58.40.33,FAC-1-2-1-1,2WAY,CLIENT:CKTID=OCHCC_Rock,VALMODE=FULL,VALZONE=RED:;
ENT-CPS::CHAN-1-2-2:1::10.64.107.36,CHAN-1-3-2,1WAY,ADD:RESTTYPE=REVERT,REVERTMODE=MANUAL,SOAK=00-00-15;
ENT-CPS::CHAN-1-2-2:1::10.64.107.36,CHAN-1-3-2,1WAY,ADD:RESTTYPE=REVERT,REVERTMODE=MANUAL,SOAK=00-00-15,CKTLABEL=LABEL__6,FREQ=195900.00,WIDTH=50.00,CKTPRIORITY=0,ALLOWRGN=N,PATHPOLICY=ANY,USPWROFS=0.0,DSPWROFS=0.0;
Input Parameters
Source access identifier from the “ALL” section. Listable. |
|
Destination AID from the “ALL” section. |
|
A unidirectional connection from a source to a destination port. Deafult is 1WAY |
|
(Optional) Circuit identification parameter contains the Common Language Circuit ID or other alias of the circuit being provisioned. Does not contain blank spaces. CKTID is a string of ASCII characters. The maximum length of CKTID can be 48. |
|
The optical validation is performed as indicated in VALZONE parameter |
|
Identifies the validation operate zone for secondary circuit |
|
Specifies the restoration type on CPS circuit or UNI configuration. Parameter type is RESTTYPE. |
|
Specifies the revertive mode type. Paraneter type is REVERTMODE. |
|
Circuit is automatically revertible after the soak time expires. |
|
This is the soak time specified in HH-MM-SS format. After the soak time expires, if the revertive mode is AUTO, the circuit reverts automatically. If revertive mode is MANUAL, the soak time is ignored. |
|
14.9 ENT-CRS-<PATH>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter STS Cross-Connection for STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS96C, STS6C, STS9C, VT1, or VT2 (ENT-CRS-<PATH>) command creates a synchronous transport signal (STS) cross-connection with a cross-connection type (CCT). Refer to the Cisco ONS SDH and Cisco ONS 15600 SONET TL1 Reference Guide for specific ring provisioning procedures.
Usage Guidelines
See Table 30-1 for supported modifiers by platform.
When a path protection cross-connection is created, the path presented by the first AID is configured to be the preferred path. For example, the AID (F1) of the cross-connection (created by ENT-CRS-STS1::F1&F2,T1:123;) is the preferred path.
The following guidelines also apply:
- The default cross-connection type is two-way.
- If a path is already in a connection, it cannot be in another connection even if the existing connection is one-way and the new one will be one-way in the other direction.
- This command does not support creating multiple STS cross-connections.
- The path protection STS cross-connection can be created by using “&” in the AID fields of this command.
– The following command is used to create a one-way selector or two-way selector and bridge with F1, F2 as from points and T1 as the to point:
ENT-CRS-{STS_PATH}:[<TID>]:F1&F2,T1:<CTAG>::[<CCT>];
– The following command is used to create a one-way bridge or two-way selector and bridge with F1 as the from point and T1, T2 as the to points:
ENT-CRS-{STS_PATH}:[<TID>]:F1,T1&T2:<CTAG>::[<CCT>];
– The following command is used to create a one-way subtending path protection connection or two-way subtending path protection connection with F1, F2 as the from points and T1, T2 as the to points:
ENT-CRS-{STS_PATH}:[<TID>]:F1&F2,T1&T2:<CTAG>::[<CCT>];
– The following command is used to create a two-way selector and bridge with F1,F2 (F1 is the working side, F2 is the protect side) as the from points and S1, S2 (S1 is the working side, S2 is the protect side) as the selector points:
ENT-CRS-{STS_PATH}:[<TID>]:F1&F2,S1&S2:<CTAG>::2WAY;
– The following command is used to create a path protection integrated dual-ring interconnect (IDRI) cross-connection:
ENT-CRS-{STS_PATH}:[<TID>]:A&B,C&D:<CTAG>::2WAYDC;
A: Path on Ring X to which traffic from Ring Y is bridged
B: Path on Ring X to which traffic from the same ring is bridged
C: Path on Ring Y to which traffic from Ring X is bridged
D: Path on Ring Y to which traffic from the same ring is bridged
A, B, C, and D have a positional meaning. Connection type 2WAYDC is used for path protection IDRI cross-connections.
– The following command is used to create a path protection dual-ring interconnect (DRI) cross-connection:
ENT-CRS-{STS_PATH}:[<TID>]:A&B,C:<CTAG>::2WAYDC;
A: Path on Ring X to which traffic from Ring Y is bridged
B: Path on Ring X to which traffic from the same ring is bridged
A, B, C, and D have a positional meaning. Connection type 2WAYDC is used for path protection DRI cross-connections.
- All A&B AIDs in the TL1 cross-connection command are in the WorkingAID&ProtectAID format.
- To establish a cross-connection on a two-fiber protection path or on a four-fiber protection channel, the protection channel access (PCA) connection type (1WAYPCA or 2WAYPCA) is required.
- If you send a PCA cross-connection type on the non-PCA AIDs, the IIAC error message is returned.
- If you send a non-PCA cross-connection type on the PCA AIDs, the IIAC error message is returned.
- The facility AID is only valid on slots with a G1K-4 card installed.
- The virtual facility AID (VFAC) is only valid on slots holding an ML-Series card.
- Both DRITYPE and DRINODE have been optional fields since Release 5.0 to support the BLSR-DRI feature. DRITYPE is applied only if the CCT is drop-and-continue (1WAYDC or 2WAYDC), and defaults to path protection for the DRI. DRINODE must be specified only if at least one end of the connection is on the BLSR, and defaults to NA.
- The DS3XM-12 card allows portless STS1/VT1.5 cross-connection provisioning on the DS3XM-12 PORTLESS ports (port number > = 12).
- CKTID is a string of ASCII characters. The maximum length of CKTID is 48. If the CKTID is EMPTY or NULL the field will not appear.
- STS18c and STS36c cross-connects are only supported on the FC_MR-4 card and optical cards.
- LO CCAT is not applicable for ML-100T-8 and CE-100T-8 cards.
Category
Security
Input Format
ENT-CRS-<PATH>:[<TID>]:<SRC>,<DST>:<CTAG>::[<CCT>]:[DRITYPE=<DRITYPE>],
[DRINODE=<DRINODE>],[CKTID=<CKTID>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Input Example
ENT-CRS-STS3C:BODEGA:STS-5-1-1&STS-6-1-1,STS-12-1-1&STS-13-1-1:116::1WAYDC:
DRITYPE=BLSR,DRINODE=PRI,CKTID=CKTID,CMDMDE=FRCD:IS,AINS;
Input Parameters
Source access identifier from the “ALL” section. Listable. |
|
Destination AID from the “ALL” section. |
|
Type of connection. Used for specifying one or two-way connections. Default is 2-way. The parameter type is CCT, which is the type of cross-connect that will be created. |
|
A unidirectional connection from a source tributary to a destination tributary. |
|
A bidirectional connection between the two tributaries. Note 1WAYMON is not supported with TL1. However, it is still supported from the Cisco Transport Controller (CTC). Using CTC, you can create 1WAYMON cross-connects that can be retrieved through TL1. |
|
A unidirectional connection from a source tributary to a destination tributary on the protection path/fiber. |
|
A bidirectional drop-and-continue connection applicable only to path protection traditional and integrated DRIs. |
|
A bidirectional connection between the two tributaries on the extra protection path/fiber. |
|
Diagnostic cross-connect. Supports BERT (BLSR PCA diagnostic cross-connect). |
|
DRI connection type. Applied only if the CCT is a drop-and-continue connection type (1WAYDC or 2WAYDC). Defaults to path protection. The parameter type is DRITYPE (DRI type). |
|
Dual ring interconnect node. The parameter type is DRINODE (DRI node). |
|
Cross-connect ID. Defaults to blank or none. CKTID is a string. |
|
The parameter type is command mode (CMDMDE). Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in IS-NR or OOS-AU,AINS service states. |
|
Force the system to override a state where the command would normally be denied. |
|
Execute the command normally. Do not override any conditions that could make the command fail. |
|
Primary state. Defaults to IS. The parameter type is primary state (PST), which indicates the current overall service condition of an entity. |
|
Secondary state. Defaults to AINS. The parameter type is SST, which provides additional information pertaining to PST and primary state qualifier (PSTQ). |
|
14.10 ENT-CRS-ETH
Enter Cross-Connect Ethernet (ENT-CRS-ETH) command allocates an Ethernet Connection. The user need to specify two or more ethernet connection end points inside ethernet facilities in order to allocate the connection inside the node. According to the specified ethernet facilities, the connection allocated can be a pass-through, add or drop or multi-drop.
Usage Guidelines
The ethernet connection end point identifier must be the same for all the ethernet ports inside the connection and must be kept the same for all the ethernet circuit.
The client and trunk facilities involved in cross-connection is set in UNI and NNI network mode respectively.
The ethernet connection can be allocated in 2WAY (bidirectional) mode.
AID rule to be used for different cases:
- only one source AID can be specified
- one or more destination (drops) AID can be specified
- In both cases the AID specifies a valid ethernet facility and a connection end point identifier within the valid range.
- CKTID is a string of ASCII characters. The maximum length of CKTID can be 48. If the CKTID is EMPTY or NULL this field is not displayed.
Category
Security
Input Format
ENT-CRS-ETH:[<TID>]:<SRC>,<DST>:<CTAG>::[<ECT>]:[CKTID=<CKTID>][:];
Input Example
ENT-CRS-ETH:VA454-22:ETH-1-3-1-1-13,ETH-1-3-21-1-13:116::2WAY:CKTID=ETHCIRCUIT:;
Input Parameters
14.11 ENT-EQPT
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Equipment (ENT-EQPT) command enters the card type and attributes for a given equipment slot in the NE. It also automatically enters all facilities supported by the card and assigns default values to all facility and path attributes. The ENT-EQPT command is also used to preprovision an NE configured in multishelf mode. This command can also be used to create PPM.
Usage Guidelines
The command supports optional parameters: RVTM (revertive time), RVRTV (revertive behavior), PROTID (unique protection ID), and PRTYPE (protection type) for configuring the card in an equipment protection group. PRTYPE can be 1:1 or 1:N. These parameters can only be entered for a working AID. The protect card must already be provisioned before creating the protection group.
This command creates a 1:1 protection group. If the command has the optional parameters for creating a protection group and the protection group cannot be created due to an error condition, provisioning of the equipment fails. 1:1 protection involves the odd slot protecting the even slot. The work-protect pair is 2-1, 4-3, 6-5, 16-17, 14-15, 12-13. The DS1, DS3, DS3XM, DS3N, DS3E, EC1 and other electrical cards support 1:1 protection. The value of PROTID is the protecting slot and has a “Slot-x” format.
The PROTID slot must be provisioned first.
To create 1:1 with the ENT-EQPT command, do not provision a working card first.
The following is an example for a 1:1 protection group:
ENT-EQPT:[<TID>]:SLOT-1:<CTAG>::DS1;
ENT-EQPT:[<TID>]:SLOT-2:<CTAG>::DS1:PROTID=SLOT-1,PRTYPE=1-1,RVTM=5.0,
RVRTV=Y;
The ENT-EQPT command creates a 1:N protection group or adds a new card to an existing 1:N protection group. Multiple working AIDs can be entered in a protection group. 1:N protection is always revertive. For 1:N protection, the protect slot can only be Slot 3 or Slot 15. For a protect card in Slot 3, the working cards can be in any of the slots on Bank A. Slot 15 is for protection in Bank B. A DSXN (DS1N or DS3N) card must be provisioned in the protect slot. 1:1 protection cannot be upgraded to 1:N protection.
The following is an example of provisioning a 1:N protection group with the ENT-EQPT command:
ENT-EQPT:[<TID>]:SLOT-3:<CTAG>::DS1N;
ENT-EQPT:[<TID>]:SLOT-2&SLOT-1:<CTAG>::DS1:PROTID=SLOT-3,PRTYPE=1-N;
The following is an example of provisioning a 1:N protection group with the ED-EQPT command:
ENT-EQPT:[<TID>]:SLOT-1&SLOT-2:<CTAG>::DS1;
ENT-EQPT:[<TID>]:SLOT-3:<CTAG>::DS1N;
ED-EQPT:[<TID>]:SLOT-2&SLOT-1:<CTAG>:::PROTID=SLOT-1,PRTYPE=1-N;
Note The ENT-EQPT command provisions a new card and adds it to the protection group. The ED-EQPT command adds the already provisioned cards to the protection group.
If the provisioning fails for some AIDs, PRTL responses will indicate failed AIDs. If the provisioning fails for all the AIDs, a DENY response occurs. CMPLD and PRTL responses for protection group queries indicate that the protection group has been successfully created for the AID(s) query.
The following is an example for 1:N protection. The RVRTV parameter is not valid for 1:N protection.
ENT-EQPT:[<TID]>:SLOT-2:<CTAG>:::PROTID=SLOT-3,PRTYPE=1-N,RVTM=5.0;
Both ENT-EQPT and ED-EQPT commands can provision all working AIDs (1-5) together for 1:N by using listed AIDs. The protect AID should already be provisioned for either command because protection group parameters are not supported for the protect AID.
The ENT-EQPT command provisions a card successfully in an empty slot if the equipment type is compatible with the slot number. This command can have the optional parameters in the “f” block to provision a card as a working card. It has the effect of adding the protection behavior at the time of provisioning itself. For the protection provisioning to succeed, the protect card should have already been provisioned. Trying to execute ENT-EQPT to provision a protection group on an already provisioned card will result in an error.
The following is an example of provisioning a 1:1 protection group:
The following is an example of provisioning a 1:N protection group:
ENT-EQPT::SLOT-1:12::DS3:PROTID=SLOT-3, |
Note ● If you send this command to provision a DS3NE card on Slot 1, 2, 4, 5, 6, 12, 13, 14,1 6, or 17, the DS3E card type is presented.
- If you send this command to provision a DS3N card on Slot 1, 2, 4, 5, 6, 12, 13, 14,1 6, or 17, the DS3 card type is presented.
- If you send this command to provision a DS1N card on Slot 1, 2, 4, 5, 6, 12, 13, 14,1 6, or 17, the DS1 card type is presented.
- For the MRC-12 card, there are hardware limitations for which Small Form-Factor Pluggable (SFP) ports can be used.
- The OC192-XFP card must be installed in Slots 5 and 6 or 12 and 13 and requires an XC10G or XC-VXC-10G cross-connect card.
Error conditions for creating 1:1 or 1:N protection groups are:
- AID sent to a non-working slot; the working cards must be in even slots for 1:1 protection, and working cards must be in the same bank and not in Slot 3 or Slot 15 for 1:N protection.
- An invalid AID was chosen for the protection slot.
- The working AID is already in a protection group.
- The AID is a protect AID.
- The protect card has a circuit.
- The equipment type does not match the allowed AID.
- The slot is already provisioned.
- The protect slot is not provisioned.
- Multiple working AIDs were sent for 1:1 protection.
- The CARDMODE provisioning is allowed on the DS3XM-12 and ML-Series cards. Provisioning for the DS3XM-12 is based on the cross-connect type and DS3XM-12 location. The following error conditions apply:
– The DS3XM-12 card in the lower speed input/output (I/O) slot with the XCVT card only allows the DS3XM-12-STS12 CARDMODE. Other cases allow the CARDMODE to be DS3XM-12-STS48.
– The NE defaults to the highest available backplane rate/mode for the DS3XM-12 card if you do not specify the CARDMODE in the ENT-EQPT command.
– The ML100T-8 card will be provisioned to MAPPER mode by default.
- The 1:N (1 <= N <= 7) protection group is allowed on the DS3XM-12 card in an ONS 15454 across two sides (A and B). All the cards in the 1:N protection group must be on the same backplane rate (or CARDMODE). The following error conditions apply:
– For 1:N protection, the protect card must be allocated on either Slot 3 or Slot 15. For 1:1 protection, the protect card must be allocated on the odd slots.
– The working DS3XM-12 cards on the opposite side of the shelf from the protection card (either Slot 3 or Slot 15) in a 1:N group can only have portless connections. The other working cards of the 1:N group on the same side of the shelf as the protection card do not have this limitation.
For example, suppose that there is a DS3XM-12 card 1:N group on Slot 2, Slot 3, Slot 4, Slot 12, and Slot 16, where Slot 3 is the protect card. Slot 2, Slot 4, Slot 12, and Slot 16 are the working cards in the 1:N (1:5) protection group. According to the above limitation rule, the Slot 12 and Slot 16 cards need to have the portless provisioning only, while the Slot 2 and Slot 4 cards can be either portless or ported provisioning.
CMDMDE provisioning behaves as follows:
– If the command mode (CMDMDE) is set to NORM during the creation of a 1:1 or 1:N protection group, all cards must be physically plugged in and in the service state (IS). If the cards are not physically plugged in and are not in ready state, the command is denied with an appropriate error message. CMDMDE=FRCD will override the default behavior and allow creation of protection group regardless of the physical presence and ready state of cards.
– If the command mode is set to NORM during the removal of a card in a 1:1 or 1:N protection group, there must be no cross-connects (for example, services) present on the card. CMDMDE=FRCD will override the default behavior and allow deletion of protection group regardless of presence of cross-connects on the card.
- RETIME provisioning is allowed only on the DS1/E1-56 card (ONS 15454).
- The protection group is automatically created when both the working and protect cards are provisioned; therefore, protection groups cannot be created using the ENT-EQPT or ED-EQPT commands. A protection group can be deleted by deleting the protect card (DLT-EQPT). Trying to delete the working card will result in the Equipment In Use (SPLD) error.
Category
Security
Input Format
ENT-EQPT:[<TID>]:<AID>:<CTAG>::<AIDTYPE>:[PROTID=<PROTID>],[PRTYPE=<PRTYPE>],[RVRTV=<RVRTV>],[RVTM=<RVTM>],[CARDMODE=<CARDMODE>],[PEERID=<PROTID>],[REGENNAME=<REGENNAME>],[CMDMDE=<CMDMDE>],[TRANSMODE=<TRANSMODE>],[RETIME=<RETIME>],[SHELFROLE=<SHELFROLE>],[FRPROLE=<FRPROLE>],[FRPSTATE=<FRPSTATE>],[FRPHOLDOFFTIME=<FRPHOLDOFFTIME>],[CFMSTATE=<CFMSTATE>],[CCTIMER=<CCTIMER>],[SWITCHWITHCRCALARM=<SWITCHWITHCRCALARM>],[CRCTHR=<CRCTHR>],[CRCPOLLINTRVL=<CRCPOLLINTRVL>],[CRCSOAKCNT=<CRCSOAKCNT>],[USB=<USB>][:];
Input Example
ENT-EQPT::SLOT-15:a::GE-XP:CARDMODE=GEXP-L2ETH,SWITCHWITHCRCALARM=Y;
ENT-EQPT::SLOT-15:a::GE-XP:CARDMODE=GEXP-L2ETH,CRCPOLLINTRVL=4;
Input Parameters
|
|
---|---|
Access identifier from the “EQPT” section. AR-MXP, AR-XP, and AR-XPE cards use the VFAC AID. |
|
(Optional) The type of facility, link or other addressable entity targeted by the message. The parameter type is EQUIPMENT_TYPE (equipment type). It is the type of equipment being provisioned. |
|
Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid |
|
Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid |
|
2-port interface card supporting 1000BaseT Ethernet facilities |
|
12-port interface card supporting 100BaseT Ethernet facilities |
|
Four-port interface card supporting 100BaseT Ethernet facilities |
|
The equipment type for FMEC STM1E12 card with 1:3 protection |
|
The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards |
|
16-channels - 1 direction, colorless, omnidirectional add/drop unit. |
|
4-channels, 4-directions, colorless, omnidirectional add/drop unit. |
|
Fast Ethernet switch card used for internal shelf connection |
|
A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64 |
|
An interface card that supports one or more STM4 (622 Mbps) optical facilities |
|
An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities |
|
An interface card that supports one long range STM4 (622 Mbps) optical facilities |
|
An interface card that supports one short range STM4 (622 Mbps) optical facilities |
|
An interface card that supports one or more STM64 optical facilities |
|
An interface card that supports multiple STM1 (155 Mbps) optical facilities |
|
An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities |
|
An interface card that supports four short range STM1 (155 Mbps) optical facilities |
|
An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers |
|
An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G |
|
An interface card that supports four short range STM1 (155 Mbps) POS optical facilities |
|
An interface card that supports one or more STM16 (10 Gbps) optical facilities |
|
An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot |
|
An interface card that supports one short range STM16 (2.5 Gbps) optical facility |
|
An interface card that supports one intermediate range STM16 (10 Gbps) optical facility |
|
An interface card that supports one long range STM16 (10 Gbps) optical facility |
|
An interface card that supports one short range STM16 (10 Gbps) optical facilities |
|
Indicates there is no protection group. Used when trying to delete a protection group. |
|
(Optional) Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to SNCP. The parameter type is ON_OFF, which disables or enables an attribute. |
|
(Optional) Revertive time. RVTM is not allowed to be set while RVRTV is N. Only applies to SNCP. The parameter type is REVERTIVE_TIME (revertive time). |
|
The parameter type is command mode (CMDMDE). Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in IS-NR or OOS-AU,AINS service states. |
|
Force the system to override a state where the command would normally be denied. |
|
Execute the command normally. Do not override any conditions that might make the command fail. |
|
(Optional) Indicates the RETIME function for all the facilities on this card. Applies only to the DS1/E1-56 card. The parameter type is ON_OFF (disable or enable an attribute). |
|
Indicates the peer trunk facility of the regeneration group on the OTU2-XP card. Accessed using the CHAN AID. |
|
Indicates the name of a regeneration group. Applicable only to DWDM flavored cards, which support regeneration group. Regenname is a string. The default value is "NULL". |
|
The role of the shelf in the context of the node. When it is omitted it defaults to SC. The parameter is SHELF_ROLE. |
|
Indicates the hold off timer value. The protection do not start until the hold off expire. |
|
Indicates the fast ring protection enable mode for GE-XP/10GE-XP units involved in a protection scheme. |
|
CRC threshold values beyond which alarms are raised. The available threshold values are 10E-2, 10E-3, and 10E-4. |
|
Number of poll cycles during which defect is integrated. The value ranges from 3 to 10. |
|
14.12 ENT-FFP-<MOD2DWDMPAYLOAD>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Facility Protection Group for 10GFC, 10GIGE, 40GIGE, 100GIGE, 1GFC, 1GFICON, 2GFC, 4GFC, 2GFICON, 8GFC, D1VIDEO, DV6000, DVBASI, ETRCLO, FSTE, GIGE, HDTV, ISC1, ISC3, ISC3STP1G, ISC3STP2G, OTU1, OTU2, OTU3, OTU4, PASSTHRU, or OCH (ENT-FFP-<MOD2DWDMPAYLOAD>) command creates Y-cable protection on client facilities. Refer to the Cisco ONS SDH and Cisco ONS 15600 SONET TL1 Reference Guide for specific card provisioning rules.
Usage Guidelines
- Y-cable with bidirectional protection is applicable only for ISC3STP1G and ISC3STP2G payloads on the AR-MXP, AR-XP, and AR-XPE cards.
- Y-cable with unidirectional protection is applicable only for payloads other than ISC3STP1G and ISC3STP2G on the AR-MXP, AR-XP, and AR-XPE cards.
- In CFP-TXP and CFP-MXP operating modes, Y-cable is provisioned on the CHAN AID of the CFP-LC card and not on the 100G-LC-C virtual ports.
- Y-cable protection is supported on the following operational modes for 10x10G-LC, 100G-LC-C, and CFP-LC cards:
– MXP-10x10G (using 10x10G-LC and 100G-LC-C cards) operational mode with client payloads as 10GIGE and 8GFC only.
– TXP-10G (using 10x10G-LC card) operational mode with client payloads as 10GIGE and 8GFC only.
– CFP-MXP (using CFP-LC and 100G-LC-C cards) operational mode with client payload as 40GIGE.
– CFP-TXP (using CFP-LC and 100G-LC-C cards) operational mode with client payload as 100GIGE.
Category
Security
Input Format
ENT-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>,
<DST>:<CTAG>:::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];
Input Example
ENT-FFP-HDTV:CISCO:FAC-1-1-1,FAC-2-1-1:100:::PROTTYPE=Y-CABLE,
PROTID=DC-METRO-1,RVRTV=Y,RVTM=1.0,PSDIRN=BI;
Input Parameters
Source access identifier from the “FACILITY” section. The working facility uses VFAC AID. |
|
Destination access identifier from the “FACILITY” section. The protecting facility uses VFAC AID. |
|
The type of facility protection. The parameter type is PROTTYPE (protection type for dense wavelength division multiplexing [DWDM] client facilities). |
|
Y-cable protection for the client ports on TXP_MR_10G, MXP_2.5G_10G, TXP_MR_2.5G, TXPP_MR_2.5G, AR_MXP, and AR_XP cards. |
|
1 + 1 L2 Protection for the client ports on 10GE XP and GE XP |
|
Protection group identifier. Defaults to the protect port AID of the protection group. The identifier is a string that can have a maximum length of 32 characters. |
|
Revertive mode. The value Y indicates that protection switching system reverts service to the original line after restoration. The value N indicates that protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF (disable or enable an attribute). |
|
Revertive time. Defaults to 5.0 minutes. The parameter type is REVERTIVE_TIME (revertive time). |
|
Protection switch operation. Identifies the switching mode. Defaults to UNI. Note TXP_MR_10G and MXP_2.5G_10G cards do not support bidirectional switching. Parameter type is UNI_BI (unidirectional and bidirectional switch operations). |
|
14.13 ENT-FFP-<OCN_TYPE>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Facility Protection Group for OC-3, OC-12, OC-48, OC-192, or OC768 (ENT-FFP-<OCN_TYPE>) command creates optical 1+1 protection.
Usage Guidelines
See Table 30-1 for supported modifiers by platform.
Note ● The protect AID must not be provisioned with traffic.
- The working AID can be provisioned with traffic.
- PROTID is a string and can have a maximum length of 32 characters.
- Optimized 1+1 protection and related attributes are only applicable to the ONS 15454.
- The following parameters are supported in Software Release 6.0 and later: OPOTYPE, VRGRDTM, DTGRDTM, and RCGRDTM.
- The following 1+1 protection group rules apply to the MRC-12 card:
– A 1+1 protection group can only be created between MRC-12 cards. You cannot create a 1+1 protection group between an MRC-12 card and an OC-48 card, for example.
– A 1+1 protection group can be created only using the same port number. For example, a protection group cannot be created between Port 1 of Slot 5 and Port 4 of Slot 12 (assuming that Slot 5 and Slot 12 both contain MRC-12 cards).
– A 1+1 protection group cannot be created between ports on the same card. For example, protection groups cannot be created between Port 1 of Slot 5 and Port 4 of Slot 5 (assuming that Slot 5 contains a MRC-12 card).
– Both the cards in the protection group must be placed in the same type of slot. Both MRC-12 cards must be in drop slots (Slots 1 to 4, 14 to 17) or both cards must be in trunk slots (Slots 5 to 6, 12 to 13). You cannot create a protection group between an MRC-12 card in a drop slot and another MRC-12 card in a trunk slot.
– A 1+1 protection group can be created between two OC192-XFP cards in trunk slots (Slots 5 to 6, 12 to 13).
– A 1+1 protection group can be created between an OC192-XFP card and an OC192LR/STM64LH card in trunk slots (Slots 5 to 6, 12 to 13).
Category
Security
Input Format
ENT-FFP-<OCN_TYPE>:[<TID>]:<WORK>,
<PROTECT>:<CTAG>:::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[OPOTYPE=<OPOTYPE>],
[VRGRDTM=<VRGRDTM>],[DTGRDTM=<DTGRDTM>],[RCGRDTM=<RCGRDTM>][:];
Input Example
ENT-FFP-OC-3:PETALUMA:OC3-3-1-1,OC3-3-2-1:1:::PROTTYPE=Y-CABLE,
PROTID=PROT_NAME,RVRTV=Y,RVTM=1.0,PSDIRN=BI,OPOTYPE=STANDARD,
VRGRDTM=0.5,DTGRDTM=1.0,RCGRDTM=1.0;
Input Parameters
14.14 ENT-FOG
(Cisco ONS 15454) The Enter Fan-Out-Group (ENT-FOG) command creates the Fan-Out-Group.
Usage Guidelines
- This command is used to provision the CPT 50 panel and applied on the carrier packet transport (CPT) system.
- The FOG can be created on a PTSYS AID.
- A 10 GIGE interface provisioned on the CPT 50 panel must be attached when you create the FOG.
- Interfaces that are valid for a particular FOG can be attached.
- Interface attached to one of the FOG cannot be attached to any other FOG.
Category
Security
Input Format
ENT-FOG[:<TID>]:<AID>:<CTAG>:::FOGID=<FOGID>,ATTACH=<ATTACH>,QUEUEMODE=<QUEUEMODE>,[PBNAME=<PBNAME>];
Input Examples
Input Parameters
AID of the PTSYS on which the FOG is being created. Access identifier from the “EQPT” section. |
|
This is the FOGID. FOG AID is created using the FOGID. The valid range is from 36 to 55. |
|
AID of the fabric and line card ports used as the Fan-out members. This is the AID of the interface to be attached to the FOG. |
|
14.15 ENT-FTPSERVER
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter FTP Server (ENT-FTPSERVER) command creates FTP server entries.
Usage Guidelines
Category
Security
Input Format
ENT-FTPSERVER:[<TID>]::<CTAG>:::IPADDR=<IPADDR>,IPMASK=<IPMASK>,ENABLE=<ENABLE>,[TIMER=<TIMER>];
Input Examples
1. ENT-FTPSERVER:::A:::IPADDR=10.20.30.40,IPMASK=255.0.0.0,ENABLE=Y,TIMER=30;
2. ENT-FTPSERVER:TID::CTAG:::IPADDR=“[3ffe:0501:0008:0000:0260:97ff:fe40:efab/64]”,ENABLE=Y,TIMER=45;
Input Parameters
14.16 ENT-LMP-CTRL
(Cisco ONS 15454) The Enter Link Management Protocol Control Channel (ENT-LMP-CTRL) command creates an LMP control channel.
Usage Guidelines
This command is only available on nodes where the LMP is available and has been enabled.
Category
Security
Input Format
ENT-LMP-CTRL:[<TID>]:<SRC>:<CTAG>:::[LOCALPORT=<LOCALPORT>], [REMOTENE=<REMOTENE>],REMOTEIP=<REMOTEIP>,[HELLO=<HELLO>],
[HELLOMIN=<HELLOMIN>],[HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>],
[DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>]:[<PST>][,<SST>];
Input Example
ENT-LMP-CTRL:PETALUMA:CTRL-123:704:::LOCALPORT=FAC-1-1-1,
REMOTENE=15.15.15.115,REMOTEIP=126.0.0.1,HELLO=500,
HELLOMIN=300,HELLOMAX=5000,DEAD=12000,DEADMIN=2000,
DEADMAX=20000:OOS,DSBLD;
Input Parameters
14.17 ENT-LMP-DLINK
(Cisco ONS 15454) The Enter Link Management Protocol Data Link (ENT-LMP-DLINK) command creates an LMP data link.
Usage Guidelines
This command can only be used on nodes where the LMP protocol is available and enabled.
Category
Security
Input Format
ENT-LMP-DLINK:[<TID>]:<SRC>:<CTAG>:::[LINKTYPE=<LINKTYPE>],TELINK=<TELINK>,
REMOTEID=<REMOTEID>;
Input Example
ENT-LMP-DLINK:PETALUMA:FAC-14-1-1:704:::LINKTYPE=PORT,TELINK=TLNK-45,
REMOTEID=646631;
Input Parameters
Access identifier from the “FACILITY” section. |
|
14.18 ENT-LMP-TLINK
(Cisco ONS 15454) The Enter Link Management Protocol Traffic Engineering Link (ENT-LMP-TLINK) command creates an LMP Traffic Engineering (TE) link.
Usage Guidelines
This command can only be used on nodes where LMP is available and enabled.
Category
Security
Input Format
ENT-LMP-TLINK:[<TID>]:<SRC>:<CTAG>:::REMOTEID=<REMOTEID>, REMOTETE=<REMOTETELINK>, [MUXCAP=<MUXCAP>]:[<PST>[,<SST>]];
Input Example
ENT-LMP-TLINK:PETALUMA:TLINK-123:704:::REMOTEID=15.15.15.115,REMOTETE=123,
MUXCAP=LAMBDA:OOS,DSBLD;
Input Parameters
Primary state. This parameter indicates the current overall service condition of an entity. |
|
Secondary state. This parameter provides additional information pertaining to PST and PSTQ. |
|
14.19 ENT-LNK
(ONS 15454) The Enter Optical Link (ENT-LNK) command creates an optical link between two optical connection points.
The optical links can be established between:
- Two optical transport sections (OTSs)
- Two optical multiplexing sections (OMSs) with the same band
- Two optical channels (OCHs) with the same wavelength
Usage Guidelines
The created optical link must be between points belonging to the same ring direction. An optical link between two OMSs or between two OCHs can be HITLESS if the connection is between two points from one drop point to a consecutive add point in the logical link. When this command is used to create an optical link between two OCH ports, where the first port belongs to an OCH filter and the second port is an OCH trunk, the second port should be tuned to the same wavelength of the OCH filter if it has not been set yet.
Category
Security
Input Format
Input Example
ENT-LNK:PENNGROVE:CHAN-6-2,CHAN-13-1-RX:114::::OOS,AINS;
ENT-LNK:PENNGROVE:CHAN-6-3-1,CHAN-13-1-RX:114::::OOS,AINS;
ENT-LNK:PENNGROVE:CHAN-6-19-1,CHAN-13-1-RX:114::::OOS,AINS;
Input Parameters
Identifier at one end of the optical link from the “CHANNEL” section, “BAND” section, or “LINE” section. |
|
Identifier at the other end of the optical link from the “CHANNEL” section, “BAND” section, or “LINE” section. |
|
Primary state of the entity. The parameter type is PST (primary state). Indicates the current overall service condition of an entity. |
|
Secondary state of the entity. The parameter type is SST (secondary state). Provides additional information pertaining to PST and PSTQ. |
|
14.20 ENT-LNKTERM
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The ENT-LNKTERM command creates a provisionable patchcord (PP) termination (virtual link) on a physical interface. A user-provisioned link is needed when the data communications channel/generic communications channel (DCC/GCC) is transparently carried over several physical links, and the physical link cannot be automatically discovered by Open Shortest Path First (OSPF) due to lack of control-channel termination or non-support of SONET by the link.
Usage Guidelines
The error message “Provisioning Rules Failed” is returned if the provisioning rules are not satisfied. The following rules must be satisfied while creating a provisionable patchcord termination on a physical interface:
– A Section DCC (SDCC) termination must be provisioned. If it is the protect facility in a 1+1 protection group, the corresponding working facility must have an SDCC termination provisioned.
– If the port is part of a BLSR, the SDCC must be provisioned on all of the working ports of the BLSR.
- For a TXP/MXP trunk port, either ITU-T G.709 must be enabled or the payload type must be non-SONET/SDH.
- For a TXP/MXP client port, a card must be operating in the transparent termination mode.
- For a DWDM OCH port:
– If the OC-N interface is part of a 1+1 protection group, a separate PP termination can be provisioned on the other (working/protect) interface also.
– If the client interface is part of a Y-cable protection group, a separate PP termination can be provisioned on the other (working/protect) interface also.
– If the MXP/TXP trunk interface is part of a splitter protection group, a separate PP termination can be provisioned on the other (working/protect) interface also.
– If REMOTENODE is specified as an IP address (or a node name that can be resolved by the gateway network element [GNE]) that is different from the local node’s IP address/name, this termination is intended to be a part of an internode provisionable patchcord.
– All endpoints of the provisionable patchcord need to be provisioned correctly (on the local and/or remote node) for it to show as UP in OSPF.
– Misconfigured or partially configured provisionable patchcords will not cause alarms or events to be generated at either end of the link.
– No two provisionable patchcord terminations on a node can be configured to have the same remote node PP termination information (for example, the combination of values for REMOTENODE and REMOTELNKTERMAID attributes for a PP termination must be unique on a single node).
– All provisionable patchcord terminations on one physical interface must have their remote terminations on a single remote node.
Category
Security
Input Format
ENT-LNKTERM:[<TID>]:<AID>:<CTAG>:::PORT=<PORT>,
[REMOTENODE=<REMOTENODE>],REMOTELNKTERMID=<REMOTELNKTERMID>;
Input Example
ENT-LNKTERM::LNKTERM-1:CTAG:::PORT=FAC-5-1,REMOTENODE=172.20.208.225,
REMOTELNKTERMID=20;
Input Parameters
Access identifier from the “LNKTERM” section. Indicates a link (provisionable patchcord) termination on the local node. For R9.6.0, the integer value can be within the range of 1 to 146. For R9.6.0.3, the integer value can be within the range of 1 to 65535. |
|
The local port corresponding to this provisionable patchcord termination from the “CHANNEL” section. |
|
The node where the other end of the provisionable patchcord resides. This can be an IP address or a valid TID. Defaults to the IP address of the local node/existing value. REMOTENODE is a string. |
|
The corresponding provisionable patchcord termination on the remote node (as specified by the REMOTENODE parameter). Integer value within the range of 1 to 65535. Defaults to existing value. For R9.6.0, the integer value can be within the range of 1 to 146. For R9.6.0.3, the integer value can be within the range of 1 to 65535. |
14.21 ENT-MA-CFM
(Cisco ONS 15454) The Enter Maintenance Association Connectivity Fault Management (ENT-MA-CFM) command adds the maintenance association on the card.
Usage Guidelines
Category
Security
Input Format
ENT-MA-CFM:[<TID>]:<AID>:<CTAG>:::MANAME=<MANAME>,SVLANID=<SVLANID>,[<CCENABLE=CCENABLE];
Input Example
ENT-MA-CFM:454-156:SLOT-1:1:::MANAME=MANAME,SVLANID=4,CCENABLE=Y;
Input Parameters
Access identifier from the “EQPT” section. |
|
Maintenance Association Name. It is a string. The MA name length should not exceed more than 43 characters. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
14.22 ENT-MD-CFM
(Cisco ONS 15454) The Enter Maintenance Domain Connectivity Fault Management (ENT-MD-CFM) command adds the maintenance domain on the card.
Usage Guidelines
Category
Security
Input Format
ENT-MD-CFM:[<TID>]:<AID>:<CTAG>:::MDNAME=<MANAME>,LEVEL=<LEVEL>;
Input Example
Input Parameters
Access identifier from the “EQPT” section. |
|
Maintenance Domain Name. It is a string. The MD name length should not exceed more than 43 characters. |
|
This indicates the level of the maintenance domain. The value ranges from 0 to 7. |
14.23 ENT-MDMAMAP-CFM
(Cisco ONS 15454) The Enter Maintenance Domain and Maintenance Association mapping Connectivity Fault Management (ENT-MDMAMAP-CFM) command creates the maintenance domain and maintenance association mapping.
Usage Guidelines
Category
Security
Input Format
ENT-MDMAMAP-CFM:[<TID>]:<AID>:<CTAG>:::MDNAME=<MANAME>,SVLANID=<SVLANID>,MANAME=<MANAME>;
Input Example
ENT-MDMAMAP-CFM::SLOT-17:1:::MDNAME=CISCO,SVLANID=6,MANAME=MA_1;
Input Parameters
Access identifier from the “EQPT” section. |
|
Maintenance Domain Name. It is a string. The MD name length should not exceed more than 43 characters. |
|
Maintenance Association Name. It is a string. The MA name length should not exceed more than 43 characters. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
14.24 ENT-MEP-CFM
(Cisco ONS 15454) The Enter Maintenance End Point Connectivity Fault Management (ENT-MEP-CFM) command creates the maintenance end points on the port.
Usage Guidelines
Category
Security
Input Format
ENT-MEP-CFM:[<TID>]:<AID>:<CTAG>:::SVLANID=<SVLANID>,MDNAME=<MDNAME>,MPID=<MPID>;
Input Example
Input Parameters
Access identifier from the “ETH” section. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
Maintenance Domain Name. It is a string. The MD name length should not exceed more than 43 characters. |
|
This indicates the level of the maintenance domain. The value ranges from 0 to 7. |
14.25 ENT-MIP-CFM
(Cisco ONS 15454) The Enter Maintenance Intermediate Point Connectivity Fault Management (ENT-MIP-CFM) command creates the maintenance intermediate points on the port.
Usage Guidelines
Category
Security
Input Format
ENT-MIP-CFM:[<TID>]:<AID>:<CTAG>:::VLANID=<VLANID>,LEVEL=<LEVEL>;
Input Example
Input Parameters
Access identifier from the “ETH” section. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
This indicates the level of the maintenance domain. The value ranges from 0 to 7. |
14.26 ENT-NNI-ETH
(Cisco ONS 15454) The Enter Network-to-Network Interface Ethernet (ENT-NNI-ETH) command adds a new network-to-network interface service provider VLAN ID to the NNI interface of an L2 Ethernet port.
Usage Guidelines
- The default values for all optional parameters are NE default values, but these values might not be the current value for a parameter. Use a retrieve command to obtain the current value.
- If the AID is invalid, an IIAC error message is returned.
- The ALL AID is invalid for this command.
- The L2 Ethernet port must be present when this command is executed.
- The command will be denied if the service provider VLAN ID is present.
Category
Security
Input Format
Input Example
Input Parameters
Ethernet AIDs are used to access the L2 Ethernet ports. Access identifier from the “ETH” section. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
14.27 ENT-NNI-CHGRP
(Cisco ONS 15454) The Enter Channel Group Network-to-Network Interface (ENT-NNI-CHGRP) command adds the NNI S-VLAN ID for the NNI of a channel group.
Usage Guidelines
- The default values for all optional parameters are NE default values, but these values might not be the current value for a parameter. Use the RTRV-ETH command to obtain the current value.
- If the AID is invalid, an IIAC (Invalid AID) error message is returned.
- The ALL AID is invalid for this command.
Category
Security
Input Format
Input Example
Input Parameters
Access identifier from the “CHGRP” section. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
14.28 ENT-OCHCC
(Cisco ONS 15454) The Enter Optical Channel Client Connection (ENT-OCHCC) command allocates an OCH client connection. An OCH client connection is the portion of the circuit that connects the end client ports using trail ports to an OCH network connection circuit. This allocates the portion of the circuit between the OCH filter port to the TXP/MXP or ITU-T client port.
Usage Guidelines
- The client port FAC AID must be specified in order to allocate a client channel inside the node.
- The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.
- On OTU1 and 4GFC ports, time slots are not applicable.
- ODU0START and ODU0END parameters are applicable only on GIGE and 1GFC payloads on the AR-XPE card only.
Category
Security
Input Format
ENT-OCHCC[:<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>],[CMDMDE=<CMDMDE>],[ODU1START=<ODU1START>],[ODU1END=<ODU1END>],[TSSTART=<TSSTART>],[TSEND=<TSEND>],[ODU0START=<ODU0START>],[ODU0END=<ODU0END>][:<PST>][,<SST>];
Input Example
ENT-OCHCC::VFAC-3-2-1:123:::ODU1START=1,ODU1END=1,TSSTART=1,TSEND=16;
Input Parameters
Access identifier from the “FACILITY” section. AR-MXP, AR-XP, and AR-XPE cards use the VFAC AID. |
|
Cross-connect ID. The default is Blank or None. It is a string of ASCII characters. The maximum length is 48. If CKTID is empty or null the CKTID field will not appear. |
|
The parameter type is command mode (CMDMDE). Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in IS-NR or OOS-AU,AINS service states. |
|
Force the system to override a state in which the command would normally be denied. |
|
Execute the command normally. Do not override any conditions that may make the command fail. |
|
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity. The default is IS. |
|
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ. The default is AINS. |
|
14.29 ENT-OCHNC
(Cisco ONS 15454) The Enter Optical Channel Network Connection (ENT-OCHNC) command allocates an OCH network connection.
Usage Guidelines
- Two CHANWL end points must be specified in order to allocate a wavelength channel inside the node. According to the CHANWL specified, the channel allocated can be a passthrough.
- The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use a retrieve command to obtain the current value.
Category
Security
Input Format
(For legacy package) ENT-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>::[<WCT>]:[CKTID=<CKTID>],[CMDMDE=<CMDMDE>],[WLOPWR=<WLOPWR>],[VOAATTN=<VOAATTN>]:[<PST>[,<SST>]];
ENT-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>::[<WCT>]:[CKTID=<CKTID>],[CMDMDE=<CMDMDE>],[WLOPWR=<WLOPWR>],[VOAATTN=<VOAATTN>],FREQ=<FREQ>,[WIDTH=<WIDTH>],[DSPWROFS=<DSPWROFS>],[USPWROFS=<USPWROFS>]:[<PST>][,<SST>];
Input Example
ENT-OCHNC:VA454-22:LINEWL-1-3-TX-1530.33,CHAN-4-1-RX:116::1WAY: CKTID=CIRCUIT,CMDMDE=FRCD:OOS,DSBLD;
ENT-OCHNC:VA454-22:LINEWL-1-3-TX-1530.33&CHAN-4-1-TX,
CHAN-4-1-RX&LINEWL-1-3-RX-1530.33:116::2WAYDCN:
CKTID="DCN CIRCUIT",CMDMDE=FRCD:OOS,DSBLD;
ENT-OCHNC:VA454-22:LINEWL-1-9-TX-1530.33,LINEWL-1-11-RX-1530.33:116::DIAG:
WLOPWR=1.0,VOAATTN=1.0;
Input Parameters
Source access identifier from the “CHANNEL” section. In 2-way wavelength connection sources both directions need to be indicated. |
|
Destination access identifier from the “LINEWL” section. In 2-way wavelength connection sources both directions need to be indicated. |
|
Wavelength connection type. The parameter type is WCT. The default is 1WAY. |
|
A unidirectional wavelength connection for one specified ring direction. |
|
A bidirectional wavelength connection for both the ring directions. |
|
A unidirectional maintenance wavelength connection inside 40-WXC-C cards. |
|
A bidirectional wavelength connection for both the ring directions that is also used to carry the data communication channels. |
|
Cross-connect ID. The default is Blank or None. It is a string of ASCII characters. The maximum length is 48. If CKTID is empty or null the CKTID field will not appear. |
|
The parameter type is command mode (CMDMDE). Normal (NORM) mode is the default behavior for all commands but you can specify forced (FRCD) mode to force the system to override a state where the command would normally be denied. The FRCD mode of operation is applicable to delete a virtual concatenated (VCAT) member cross-connect in IS-NR or OOS-AU,AINS service states. |
|
Force the system to override a state in which the command would normally be denied. |
|
Execute the command normally. Do not override any conditions that may make the command fail. |
|
The value of calibrated output power that the VOA is going to set as a result of its attenuation. WLOPWR is a float. |
|
The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. VOAATTN is a float. |
|
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity. The default is IS. |
|
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ. The default is AINS. |
|
14.30 ENT-OPMODE
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Operating Mode (ENT-OPMODE) command creates operating mode on a given client or trunk or peer card.
Usage Guidelines
- Enter the operating mode that is being created.
- Enter the client and trunk port numbers while creating the operating mode.
- Enter the rate on which the operating mode is created.
- PEERSLOTS parameter is applicable only on 100G-LC-C, 10x10G-LC, and CFP-LC cards. PEERSLOTS parameter values should be specified as SLOT-<SLOTNO>.
- RATE parameter is not applicable on 100G-LC-C, 10x10G-LC, and CFP-LC cards.
- In Low-latency and RGN-10G modes, one of the port is represented as Client and the other as Trunk while both are represented as trunks on CTC.
- The OPMODE parameter is a mandatory parameter for all the operating modes on the AR-MXP, AR-XP, AR-XPE, 10x10G-LC, 100G-LC-C, and CFP-LC cards.
- CLIENTPORTS and TRUNKPORTS are the mandatory parameters for all the operating modes on the AR-MXP, AR-XP, and AR-XPE cards.
- CLIENTPORTS and TRUNKPORTS are optional parameters for few operating modes on the 10x10G-LC, 100G-LC-C, and CFP-LC cards. Both these parameters are used in TXP-10G and RGN-10G modes on the 10x10G-LC Card. The CLIENTPORTS parameter is used in CFP-TXP and CFP-MXP operating modes on the CFP-LC card.
- RATE is a mandatory parameter for HIGH rate operating modes on the AR-MXP, AR-XP, and AR-XPE cards.
- CTMAP is a mandatory parameter only in MXP(P)-DME High rate modes on the AR-MXP, AR-XP, and AR-XPEcards.
- PEERSLOTS is a mandatory parameter only in dual card operating modes on the 10x10G-LC, 100G-LC-C, and CFP-LC cards. PEERSLOTS parameter value is of syntax SLOT[-SH]-<SLOTNO>.
- Following are the mandatory parameters for the operating modes on the 10x10G-LC, 100G-LC-C, and CFP-LC cards:
– OPMODE, CLIENTPORTS, and TRUNKPORTS for TXP-10G, RGN-10G, and LOW-LATENCY operating modes on the 10x10G-LC card.
– OPMODE parameter for TXP-100G operating mode on the 100G-LC-C card.
– OPMODE and PEERSLOTS parameters for RGN-100G dual card operating mode on the 100G-LC-C card along with one peer 100G-LC-C and MXP-10X10G dual card operating mode among with two peer cards 10x10G-LC and 100G-LC-C.
– OPMODE, CLIENTPORTS, and PEERSLOTS parameters for CFP-TXP dual card operating mode between CFP-LC and 100G-LC-C cards.
– OPMODE and PEERSLOTS parameters for CFP-MXP dual card operating mode between CFP-LC and 100G-LC-C cards.
Category
Security
Input Format
ENT-OPMODE[:<TID>]:<AID>:<CTAG>:::OPMODE=<OPMODE>,[PEERSLOTS=<PEERSLOTS>],[TRUNKPORTS=<TRUNKPORTS>],[CLIENTPORTS=<CLIENTPORTS>],[RATE=<RATE>],[CTMAP=<CTMAP>];
Input Example
ENT-OPMODE::SLOT-5:1:::OPMODE=CFP-TXP,CLIENTPORTS=1,PEERSLOTS=SLOT-7;
Input Parameters
14.31 ENT-QNQ-CHGRP
(Cisco ONS 15454) The Enter Channel Group QinQ (ENT-QNQ-CHGRP) command adds the IEEE 802.1Q tunneling (QinQ) relationship between the CE-VLAN and the S-VLAN for Gigabit Ethernet uniport provisioning associated to a channel group.
Usage Guidelines
- The default values for all optional parameters are NE default values, but these values might not be the current value for a parameter. Use the RTRV-ETH command to obtain the current value.
- If the AID is invalid, an IIAC (Invalid AID) error message is returned.
- The ALL AID is invalid for this command.
Category
Security
Input Format
ENT-QNQ-CHGRP:[<TID>]:<AID>:<CTAG>::<FIRST_CE_VLAN_ID>,<LAST_CE_VLAN_ID>,<S_VLAN_ID>:[RULE=<RULE>],[INTERNALVLAN=<INTERNAL_VLAN_ID>],[INGRESSCOS=<INGRESSCOS>][:];
Input Example
Input Parameters
Access identifier from the “CHGRP” section. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
Used to represent the rules allowed for the VLAN tagging operations. The default value is ADD. |
|
XLTE and ADD rule applied together. This rule request to supply an internal S-VLAN. First the Internal VLAN substitutes the Customer VLAN, then Service Provider VLAN TAG (S-VLAN) is added |
|
ADD rule applied two times. This rule request to supply an internal S-VLAN. First the Internal VLAN is added, then Service Provider VLAN TAG (S-VLAN) is added to have a double tag |
|
14.32 ENT-QNQ-ETH
(Cisco ONS 15454) The Enter QinQ Ethernet (ENT-QNQ-ETH) command enters a new IEEE 802.1Q tunneling (QinQ) relationship between the CE-VLAN and S-VLAN for Gigabit Ethernet uniport provisioning associated to an L2 Ethernet port.
Usage Guidelines
- The default values for all optional parameters are NE default values, but these values may not be the current value for a parameter. Use a retrieve command to obtain the current value.
- If the AID is invalid, an IIAC error message is returned.
- The ALL AID is invalid for this command.
- The L2 Ethernet port must be defined before executing this command or the command will be denied.
- The command will be denied if the CE-VLAN-ID and S-VLAN-ID relationship is defined before the L2 Ethernet port is defined.
Category
Security
Input Format
ENT-QNQ-ETH:[<TID>]:<AID>:<CTAG>::<FIRSTCEVLANID>,<LASTCEVLANID>,<S_VLAN_ID>[:RULE=<RULE>],[INTERNALVLAN=<INTERNAL_VLAN_ID>],[INGRESSCOS=<INGRESSCOS>][:];
Input Example
Input Parameters
Ethernet AIDs are used to access the L2 Ethernet ports. Access identifier from the “ETH” section. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
VLAN identifier. A VLAN ID is a number between 1 and 4096. The value 0 is reserved for untagged VLANs. This identifier is used for customer VLAN IDs and service provider VLAN IDs. |
|
Used to represent the rules allowed for the VLAN tagging operations. The default value is ADD. |
|
XLTE and ADD rule applied together. This rule request to supply an internal S-VLAN. First the Internal VLAN substitutes the Customer VLAN, then Service Provider VLAN TAG (S-VLAN) is added |
|
ADD rule applied two times. This rule request to supply an internal S-VLAN. First the Internal VLAN is added, then Service Provider VLAN TAG (S-VLAN) is added to have a double tag |
|
14.33 ENT-REP
(Cisco ONS 15454) The Enter Resilient Ethernet Protocol (ENT-REP) command associates the Resilient Ethernet Protocol (REP) configuration on the ethernet port of GE_XP or 10GE_XP card.
Usage Guidelines
- This command is applicable only if the card is in ETH-L2 card mode.
- This command is applicable only to GE_XP and 10GE_XP cards.
- The PORTROLE parameter can be PRIMARY, NO_NEIGHBOR, or NO_NEIGHBOR_PRIMARY only if the port is an edge port.
- If the Edge is not Enabled, the PORTROLE parameter can only be REGULAR.
- If only the segment ID is specified, by default the edge is disabled and PORTROLE is REGULAR; PREFERRED is disabled.
Category
Security
Input Format
ENT-REP:[TID>]:<AID>:<CTAG>:::<SEGMENTID=<SEGMENTID>,[EDGE=<EDGE>],[PORTROLE=<PROTROLE>],[PREFERRED=<PREFERRED>];
Input Example
ENT-REP::ETH-12-1-1:1:::SEGMENTID=1,EDGE=Y,PORTROLE=PRIMARY,PREFERRED=N;
Input Parameters
Ethernet AIDs are used to access L2 Ethernet ports. Access identifier from the “ETH” section. |
|
Indicates the segment ID for REP segment. The valid range is from 0 to 1024. |
|
The parameter type is REP_PORT_ROLE, which indicates the port’s role in a REP Segment for the ethernet ports. |
|
Indicates that the port has no neighbor port in the segment. |
|
Indicates that the port is a primary port and has no neighbor port in the segment. |
|
Indicates that the port is the preferred alternate port. Or the preferred port for VLAN load balancing. |
|
14.34 ENT-RMONTH-<MOD2_RMON>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Remote Monitoring Threshold for 10GFC, 10GIGE, 40GIGE, 100GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, 4FGC, 4GFICON, 8GFC, CHGRP, FSTE, G1000, GFP, GIGE, ETH, GFPOS, GIGE, HDLC, ISCCOMPAT, and POS (ENT-RMONTH-<MOD2_RMON>) command creates an entry in the remote monitoring (RMON) alarm table for the threshold of data statistics (for example, GIGE or FC) managed by the RMON engine. After creating the RMON threshold (RMONTH), a threshold crossing alert (TCA) event will be generated and reported to the TL1 session when the threshold is crossed. More than one threshold can be created with different parameters for each data statistic type.
Usage Guidelines
See Table 30-1 for supported modifiers by platform.
Category
Security
Input Format
ENT-RMONTH-<MOD2_RMON>:[<TID>]:<SRC>:<CTAG>::<MONTYPE>,,,,
<INTVL>:RISE=<RISE>,FALL=<FALL>,[SAMPLE=<SAMPLE>],[STARTUP=<STARTUP>][:];
Input Example
ENT-RMONTH-GIGE:CISCO:FAC-2-1:1234::ETHERSTATSOCTETS,,,,100:RISE=1000,
FALL=100,SAMPLE=DELTA,STARTUP=RISING;
Input Parameters
Source access identifier from the “FACILITY” section. AID for the facility that manages the data statistics. AR-MXP, AR-XP, and AR-XPE cards use the VFAC AID. |
|
Monitored type. Type of RMON data statistics. The parameter type is ALL_MONTYPE (monitoring type list). |
|
OTN—Background Block Error Ratio—Path Monitor Point expressed as one tenth of a percentage |
|
OTN—Background Block Error Ratio—Section Monitor Point expressed as one tenth of a percentage |
|
Errored Seconds Ratio—Path monitor Point expressed as one tenth of a percentage |
|
Errored Seconds Ratio—Section monitor Point expressed as one tenth of a percentage |
|
The total number of good packets received that were directed to a multicast address |
|
The total number of packets received that have a length (excluding framing bits, but including frame check sequence [FCS] octets) of between 64 and 1518 octets |
|
The total number of packets received that were less than 64 octets |
|
The total number of packets received that are longer than 1518 octets |
|
The total number of packets received that are longer than 1518 octets |
|
The total number of packets (including bad packets, broadcast packets, and multicast packets) received |
|
The total number of packets received that are less than 64 octets |
|
High-Order Path Negative Pointer Justification Count - Path Detected |
|
High-Order Path Negative Pointer Justification Count - Path Generated |
|
High-Order Path Pointer Justification Count Seconds - Path Detected |
|
High-Order Path Pointer Justification Count Seconds - Path Generated |
|
High-Order Path Positive Pointer Justification Count - Path Detected |
|
High-Order Path Positive Pointer Justification Count - Path Generated |
|
The number of Severely Errored Period Intensity events in available time |
|
Number of broadcast packets received since the last counter reset |
|
The number of inbound packets (or transmission units) that contained errors |
|
Number of multicast packets received since the last counter reset |
|
Number of unicast packets received since the last counter reset |
|
The number of outbound packets (or transmission units) that could not be transmitted because of errors |
|
L1 line code violations for lower rate FC. This equates to invalid 8b10b ordered sets. |
|
L1 line code violations for lower rate FC. This equates to invalid 8b10b ordered sets. |
|
Normalized value for Optical Power Transmitted for the OC3-8 card |
|
Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count) |
|
Severely Errored Second — Network Path (DS3XM-12 DS1 PM count) |
|
OTN—Severely Errored Second Ratio—Path Monitor Point expressed as one tenth of a percentage |
|
OTN—Severely Errored Second Ratio—Section Monitor Point expressed as one tenth of a percentage |
|
The interval in seconds over which the data is sampled and compared with the rising and falling threshold. A valid value is any integer larger than or equal to 10 (seconds). |
|
The rising threshold for the sampled statistic. A valid value is any integer. |
|
The falling threshold. A valid value is any integer smaller than the rising threshold. |
|
The method of calculating the threshold comparison value. The parameter type is SAMPLE_TYPE, which describes how the data will be calculated during the sampling period. |
|
Comparing with the current value of the selected variable subtracted by the last sample |
|
Dictates whether an event will generate if the first valid sample is greater than or equal to the rising threshold, less than or equal to the falling threshold, or both. The parameter type is STARTUP_TYPE, which indicates whether an event will be generated when the first valid sample is crossing the rising or falling threshold. |
|
Generates the event when the sample is smaller than or equal to the falling threshold. |
|
Generates the event when the sample is greater than or equal to the rising threshold. |
|
Generates the event when the sample is crossing the rising threshold or the falling threshold. |
14.35 ENT-ROLL-<MOD_PATH>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Roll for STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS96C, STS6C, STS9C, VC12, VC3, VT1, or VT2 (ENT-ROLL-<MOD_PATH>) command enters information about rolling of traffic from one end point to another without interrupting service. This command can be used to roll single paths (STS or VT).
Note STS18C and STS36C are not supported in this release.
Usage Guidelines
Category
Security
Input Format
ENT-ROLL-<MOD_PATH>:[<TID>]:<FROM>,<TO>:<CTAG>:::RFROM=<RFROM>,
RTO=<RTO>,RMODE=<RMODE>,[CMDMDE=<CMDMDE>];
Input Example
ENT-ROLL-STS1:CISCO:STS-1-1-1,STS-2-1-1:1:::RFROM=STS-2-1-1,RTO=STS-3-1-1,
RMODE=MAN,FORCE=Y;
Input Parameters
Source access identifier from the “STS” section, which is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the FROM-AID termination point. Otherwise, FROM is not significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue the RTRV-CRS command and use the response for FROM and TO parameters. |
|
Destination AID from the “STS” section which is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the TO-AID termination point. Otherwise, the TO is not significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue the RTRV-CRS command and use the response for FROM and TO parameters. |
|
The termination point of the existing cross-connect that is to be rolled. The termination point is an AID from the “STS” section. |
|
The termination point that will become a leg of the new cross-connection. the termination point is an AID from the “STS” section. |
|
Indicates the mode of the rolling operation. The parameter type is RMODE (roll mode). |
|
Automatic. When a valid signal is available, the roll that has the AUTO mode will automatically delete the previous end-point. |
|
Manual. Enter the corresponding delete roll/bulkroll command to delete the previous end-point. |
|
Forces a valid signal on the path. FORCE can only go from Y to N. The parameter type is ON_OFF (disable or enable an attribute). |
|
14.36 ENT-ROUTE
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Route (ENT-ROUTE) command creates static routes.
Usage Guidelines
There is no Domain Name Server (DNS) service available on the node. Only numeric IP addresses will be accepted.
Category
Security
Input Format
ENT-ROUTE:[<TID>]::<CTAG>::<DESTIP>,<IPMASK>,<NXTHOP>,<COST>;
Input Example
ENT-ROUTE:CISCO::123::10.64.72.57,255.255.255.0,10.64.10.12,200;
Input Parameters
14.37 ENT-ROUTE-GRE
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Route Generic Routing Encapsulation (ENT-ROUTE-GRE) command creates a GRE tunnel. This can be used to transport IP over Open Systems Interconnect (OSI) or OSI over IP.
Usage Guidelines
Category
Security
Input Format
ENT-ROUTE-GRE:[<TID>]::<CTAG>:::IPADDR=<IPADDR>,IPMASK=<IPMASK>,
NSAP=<NSAP>,[COST=<COST>];
Input Example
ENT-ROUTE-GRE:CISCO::123:::IPADDR=10.64.72.57,IPMASK=255.255.255.0,
NSAP=“39840F80FFFFFF0000DDDDAA000010CFB4910200”,COST=110;
Input Parameters
Network service access point (NSAP) address for the tunnel endpoint. NSAP is a string. |
|
Routing cost associated with the tunnel. COST is an integer. |
14.38 ENT-TADRMAP
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Target Identifier Address Mapping (ENT-TADRMAP) command instructs a gateway NE (GNE) to create an entry in the TADRMAP table that maps the target identifiers (TIDs) of the subtending NEs to their addresses. The operating systems (OSs) will address the subtending NEs using the TID in TL1 messages and a GNE will address these NEs by mapping the TID to an IP address or NSAP. The TADRMAP table, which resides in the GNE, correlates a TID and an address. The command requires that at least one IPADDR or NSAP be specified. The PORT and ENCODING parameters are only used with IP address mappings.
Usage Guidelines
Category
Security
Input Format
ENT-TADRMAP:[<TID>]::<CTAG>:::[TIDNAME=<TIDNAME>],[IPADDR=<IPADDR>],
[PORT=<PORT>],[ENCODING=<ENCODING>],[NSAP=<NSAP>];
Input Example
ENT-TADRMAP:TID::CTAG:::TIDNAME=ENENODENAME,IPADDR=192.168.100.52,
PORT=3082,ENCODING=LV,NSAP=“39840F80FFFFFF0000DDDDAA01001800”;
Input Parameters
14.39 ENT-TRAPTABLE
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Trap Table (ENT-TRAPTABLE) command provisions a Simple Network Management Protocol (SNMP) trap destination and its associated community, User Datagram Protocol (UDP) port, and SNMP version. The maximum number of trap entries is ten.
Usage Guidelines
Category
Security
Input Format
ENT-TRAPTABLE:[<TID>]:<AID>:<CTAG>::COMMUNITY=<COMMUNITY>,
[TRAPPORT=<TRAPPORT>],[TRAPVER=<TRAPVER>];
Input Examples
1. ENT-TRAPTABLE::1.2.3.4:1::COMMUNITY="PRIVATE",TRAPPORT=162,TRAPVER=SNMPV1;
2. ENT-TRAPTABLE::“[3ffe:0501:0008:0000:0260:97ff:fe40:efab]”:1::COMMUNITY="PRIVATE",TRAPPORT=162,TRAPVER=SNMPV1;
Input Parameters
IP address identifying the trap destination. Only a numeric IP address is allowed. Access identifier from the “IPADDR” section. |
|
Community associated with the trap destination. Community name is a string with up to 32 characters. |
|
UDP port number associated with the trap destination. The UDP port number default is 162. TRAPPORT is an integer. |
|
SNMP version number. Defaults to SNMPv1. The parameter type is SNMP_VERSION (SNMP Version). |
|
14.40 ENT-TUNNEL-FIREWALL
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Tunnel Firewall (ENT-TUNNEL-FIREWALL) command creates a firewall tunnel.
Usage Guidelines
Category
Security
Input Format
ENT-TUNNEL-FIREWALL:[<TID>]::<CTAG>:::[SRCADDR=<SRCADDR>],
[SRCMASK=<SRCMASK>],[DESTADDR=<DESTADDR>],[DESTMASK=<DESTMASK>];
Input Example
ENT-TUNNEL-FIREWALL:TID::CTAG:::SRCADDR=192.168.100.52,
SRCMASK=255.255.255.0,DESTADDR=192.168.101.14,DESTMASK=255.255.255.0;
Input Parameters
14.41 ENT-TUNNEL-PROXY
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Tunnel Proxy (ENT-TUNNEL-PROXY) command creates a proxy tunnel.
Usage Guidelines
Category
Security
Input Format
ENT-TUNNEL-PROXY:[<TID>]::<CTAG>:::[SRCADDR=<SRCADDR>],
[SRCMASK=<SRCMASK>],[DESTADDR=<DESTADDR>],[DESTMASK=<DESTMASK>];
Input Example
ENT-TUNNEL-PROXY:TID::CTAG:::SRCADDR=192.168.100.52,SRCMASK=255.255.255.0,
DESTADDR=192.168.101.14,DESTMASK=255.255.255.0;
Input Parameters
14.42 ENT-UNICFG
(Cisco ONS 15454, Cisco ONS 15454 M2, Cisco ONS 15454 M6) The Enter User Network Interface Configuration (ENT-UNICFG) command creates UNI configuration which informs the circuit that the two ports specified in the command acts as an entry or exit point of an optical circuit.
Usage Guidelines
- Before executing the ENT-UNICFG command, the node should be configured with an optical side and an internal patchcords between a multiplexer, demultiplexer, and a mesh card.
- The source port should be an ADD port and destination port should be a DROP port.
- By default, the VALMODE parameter value is FULL and the VALZONE parameter value is GREEN.
- With the VALMODE parameter value as NONE, the VALZONE parameter is not applicable.
- RESTTYPE as REVERT is not applicable for UNICFG.
Category
Security
Input Format
ENT-UNICFG:[<TID>]:<SRC>:<CTAG>::<RVRSAID>,<RSYSIP>,<RIFCIP>,<MSTPIP>,<COMMIP>:[VALMODE=<OPTVAL>],[VALZONE=<OPRZONE>],[ADMINSTATE=<ADMINSTATE>],[RESTTYPE=<RESTTYPE>],[CKTPRIORITY=<CKTPRIORITY>],[DSPWROFS=<DSPWROFS>],[USPWROFS=<USPWROFS>],[ALLOWREGEN=<ALLOWREGEN>][:];
Input Example
ENT-UNICFG::LINE-1-6-4-RX:1::LINE-1-6-4-TX,10.11.12.13,14.15.16.17,18.19.20.21,22.23.24.25:VALMODE=FULL,VALZONE=GREEN,DSPWROFS=2,ALLOWREGEN=YES;
|
|
---|---|
Source AID from the “ALL” section. |
|
Destination AID from the “ALL” section. |
|
The optical validation is performed as indicated in VALZONE parameter. |
|
Indicates Adminstate is UP and UNI Services can be activated. |
|
Indicates Adminstate is DOWN and UNI Services cannot be activated. |
|
Allow Regeneration (ALLOWREGEN)—Allows the control plane to find a regenerator in the network. The regenerators are used when an optical LSP between two endpoints is not optical or lambda feasible with a single DWDM channel. |
|
Allows the control plane to find a regenerator in the network. |
|
14.43 ENT-USER-SECU
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter User Security (ENT-USER-SECU) command adds a user account. Only a Superuser can use the ENT-USER-SECU command. Each user created by the Superuser has one of these four privilege levels:
1. Retrieve [RTRV]: Users with this security level can retrieve information from the node, but cannot modify anything. The default idle time for a Retrieve user is unlimited.
2. Maintenance [MAINT]: Users with this security level can retrieve information from the node and perform limited maintenance operations such as card resets, Manual/Force/Lockout on cross-connects or in protection groups, and BLSR maintenance. The default idle time for a Maintenance user is 60 minutes.
3. Provisioning [PROV]: Users with this security level can perform all maintenance actions, and all provisioning actions except those restricted to Superusers. The default idle time for a Provisioning user is 30 minutes.
4. Superuser [SUPER]: Users with this security level can perform all provisioning user actions, plus creating and deleting user security profiles, setting basic system parameters such as time, date, node name, and IP address, and doing database backup and restoration. The default idle time for a Superuser is 15 minutes.
Usage Guidelines
- Passwords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU, and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The CTC Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.
- n CTC, TL1 accepts the UID length of 2 to 20 characters. The minimum length for PID and the password character rule can be configured using the command SET-ATTR-SECUDFLT. If minimum length for PID is selected as 2, it is mandatory to select ANY_CHAR as the password character rule, but if the password character rule is selected as ANY_CHAR, minimum length for PID can be selected as 2 or 4 or 6 or 8 or 10 or 12.
- Prior execution of SET-ATTR-SECUDFLT command is mandatory to set the minimum password length (PWDMINLEN) and password character rule (PWDCHRULE) for the PID to be entered in ENT-USER-SECU command, else default minimum length and password character rule is applied.
- The TL1 password security is enforced as follows:
– The PID cannot be the same as or contain the UID. For example, if the userid is CISCO25 the password cannot be CISCO25#.
– The PID must have one nonalphabetic and one special (+,%, or #) character.
– PID toggling is not permitted; for example, if the current password is CISCO25#, the new password cannot be CISCO25#.
Category
Security
Input Format
Input Example
Input Parameters
14.44 ENT-VCG
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Enter Virtual Concatenated Group (ENT-VCG) command creates a VCG object. VCGs on ML-Series cards support two members. Supported subrates are STS1, STS3C, and STS12C. ML-Series VCG also supports SW-LCAS or NONE. VCG on the FC_MR-4 card supports eight members and the supported subrate is limited to STS3C. The FC_MR-4 card VCG has no link capacity adjustment scheme (LCAS) support (NONE). VCG on the ML-100T-8 card supports up to three members at a subrate of STS1 and 64 members at a subrate of VT1.
Usage Guidelines
Category
Security
Input Format
ENT-VCG:[<TID>]:<SRC>:<CTAG>:::TYPE=<TYPE>,TXCOUNT=<TXCOUNT>,[CCT=<CCT>],
[LCAS=<LCAS>],[BUFFERS=<BUFFERS>],[NAME=<NAME>];
Input Example
ENT-VCG:NODE1:FAC-1-1:1234:::TYPE=STS3C,TXCOUNT=8,CCT=2WAY,LCAS=LCAS,
BUFFERS=DEFAULT,NAME=“VCG1”;
Input Parameters
Source access identifier from the “FACILITY” section. ML1000-2 and ML100T-12 cards use the VFAC AID. The FC_MR-4 card uses the FAC AID. |
|
The type of entity or member cross-connect being provisioned. Null indicates not applicable. TYPE can be a Common Language Equipment Identification (CLEI) code or another value. ML1000-2 and ML100T-12 cards support STS1, STS3c, and STS12c. The FC_MR-4 card supports STS3c only. The parameter type is MOD_PATH (STS/VT path modifier). |
|
Number of members in the transmit (Tx) direction. For ML1000-2 and ML100T-12 cards, the only valid value is 2. For the FC_MR-4 card the only valid value is 8. TXCOUNT is an integer. |
|
Type of connection (one-way or two-way). CCT is the cross-connect type for the VCG member cross-connects. It must be the same for all the member cross-connects of a VCG. The parameter type is CCT, which is the type of cross-connect to be created. |
|
A unidirectional connection from a source tributary to a destination tributary |
|
A bidirectional connection between the two tributaries Note 1WAYMON is not supported with TL1. However, it is still supported from CTC. Using CTC, you can create 1WAYMON cross-connects that can be retrieved through TL1. |
|
A unidirectional connection from a source tributary to a destination tributary on the protection path/fiber |
|
A bidirectional drop-and-continue connection applicable only to traditional path protection configurations and integrated DRIs |
|
A bidirectional connection between the two tributaries on the extra protection path/fiber |
|
Diagnostic cross-connect. Supports BERT (BLSR PCA diagnostic cross-connect). |
|
Link capacity adjustment scheme. Note If SW-LCAS is selected, then the far-end VCG must also be configured as SW-LCAS. The parameter type is LCAS, which is the link capacity adjustment scheme mode for the VCG created. |
|
Supports the temporary removal of a VCG member during member failure. Only supported by the ML1000-2 and ML100T-12 cards. |
|
Buffer type. The default value is DEFAULT. The FC_MR-4 and CE1000 cards support DEFAULT and EXPANDED buffers. Other data cards support DEFAULT buffers only. The parameter type is BUFFER_TYPE, which is the buffer type used in the VCAT circuit. |
|
Name of the VCAT group. The name defaults to null. Its maximum length is 32 characters. NAME is a string. |
14.45 ENT-VLAN
(Cisco ONS 15454) The Enter Virtual VLAN (ENT-VLAN) command adds a new VLAN entry to the VLAN database. The VLAN database is a collection of VLANs used in an NE.
Usage Guidelines
Category
Security
Input Format
ENT-VLAN:[<TID>]:<AID>:<CTAG>:::NAME=<NAME>,[PROTN=<PROTN>],[MACLEARNING=<MACLEARNING>],[IGMPENABLE=<IGMPENABLE>],[IGMPFASTLEAVE=<IGMPFASTLEAVE>],[IGMPSUPP=<IGMPSUPP>][:];
Input Example
ENT-VLAN:ROCKS:VLAN-4096:1:::NAME=MYVLAN,PROTN=N,MACLEARNING=Y, IGMPENABLE=Y,IGMPFASTLEAVE=Y,IGMPSUPP=Y;
Input Parameters
14.46 ENT-WDMANS
(Cisco ONS 15454) The Enter Wavelength Division Multiplexing Automatic Node Setup (ENT-WDMANS) command adds the automatic optical node setup application attributes.
Usage Guidelines
Category
Security
Input Format
ENT-WDMANS:[<TID>]:<AID>:<CTAG>::[<WLEN>]:[VOAATTN=<VOAATTN>],[POWEROSC=<POWEROSC>],[NTWTYPE=<NTWTYPE>],[CHLOSS=<CHLOSS>],[GAIN=<GAIN>],[TILT=<TILT>],[CHPWR=<CHPWR>],[AMPLMODE=<AMPLMODE>],[RATIO=<RATIO>],[OSCLOSS=<OSCLOSS>],[DITHER=<DITHER>],[TOTALPWR=<TOTALPWR>],[TOTALPWRMILLIW=<TOTALPWRMILLIW>],[HIGHSLVEXP=<HIGHSLVEXP>],[LOWSLVEXP=<LOWSLVEXP>],[TOTALPWRDBM=<TOTALPWRDBM>];
ENT-WDMANS:[<TID>]:<AID>:<CTAG>::[<WLEN>]:[VOAATTN=<VOAATTN>],[POWEROSC=<POWEROSC>],[NTWTYPE=<NTWTYPE>],[CHLOSS=<CHLOSS>],[GAIN=<GAIN>],[TILT=<TILT>],[CHPWR=<CHPWR>],[AMPLMODE=<AMPLMODE>],[RATIO=<RATIO>],[OSCLOSS=<OSCLOSS>],[DITHER=<DITHER>],[TOTALPWRMILLIW=<TOTALPWRMILLIW>],[HIGHSLVEXP=<HIGHSLVEXP>],[LOWSLVEXP=<LOWSLVEXP>],[TOTALPWRDBM=<TOTALPWRDBM>],[ENABLELOGO=<ENABLELOGO>][:];
Input Example
ENT-WDMANS:PENNGROVE:WDMNODE:114::1530.33:VOAATTN=2.5,POWEROSC=5.0,NTWTYPE=METRO-CORE,CHPWR=2.0,DITHER=10,TOTALPWR=150;
Input Parameters
14.47 ENT-WDMSIDE
(Cisco ONS 15454) The Enter Wavelength Division Multiplexing Side (ENT-WDMSIDE) command adds a new WDM Node Side and defines its attributes.
Usage Guidelines
Category
Security
Input Format
ENT-WDMSIDE:[<TID>]:<AID>:<CTAG>:::LINEIN=<LINEIN>,LINEOUT=<LINEOUT>[:];
Input Example
ENT-WDMSIDE:TEXAS:WDMSIDE-A:114:::LINEIN=LINE-1-3-RX,LINEOUT=LINE-1-3-TX;