- Preface
- Cisco ONS Documentation Roadmap for Release 10.x.x
- New and Changed Information for Release 10.x.x
- Chapter 1, Overview
- Chapter 2, Provisioning Procedures
- Chapter 3, ACT Commands
- Chapter 4, ALW Commands
- Chapter 5, APPLY Commands
- Chapter 6, CANC Commands and Messages
- Chapter 7, CHG Commands
- Chapter 8, CLR Commands
- Chapter 9, CONN Commands
- Chapter 10, COPY Commands
- Chapter 11, DISC Commands
- Chapter 12, DLT Commands
- Chapter 13, ED Commands
- Chapter 14, ENT Commands
- Chapter 15, EX Commands
- Chapter 16, INH Commands
- Chapter 17, INIT Commands
- Chapter 18, OPR Commands
- Chapter 19, REPT Commands
- Chapter 20, RLS Commands
- Chapter 21, RMV Commands
- Chapter 22, RST Commands
- Chapter 23, RTRV Commands
- Chapter 24, SCHED Commands
- Chapter 25, SET Commands
- Chapter 26, SW Commands
- Chapter 27, TST Commands
- Chapter 28, Access Identifiers
- Chapter 29, Conditions
- Chapter 30, Modifiers
- Chapter 31, TL1 Errors
CHG Commands
This chapter provides change (CHG) commands for the Cisco ONS 15454, Cisco ONS 15454 M2, and Cisco ONS 15454 M6.
Note
All commands supported on the Cisco ONS 15454 platform are also supported on Cisco ONS 15454 M2 and Cisco ONS 15454 M6 platforms.
7.1 CHG-ACCMD-<MOD_TACC>
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) The Change Test Access Mode for the DS1, DS3I, E1, E3, STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS96C, STS6C, STS9C, T1, T3, VT1, or VT2 (CHG-ACCMD-<MOD_TACC>) command changes the test access (TACC) mode for the circuit being tested. This can be a change from monitoring the data to inserting data into the synchronous transport signal (STS). For more information about TACC, refer to the Cisco ONS SDH and Cisco ONS 15600 SONET TL1 Reference Guide. See Table 30-1 for supported modifiers by platform.
Usage Guidelines
This command can only be applied to an existing test access point (TAP) connection.
Note ●
If there is no TAP connection, a DENY error message is returned.
- If a requested condition already exists, a SRCN error message is returned.
- If a requested access configuration is invalid, a SRAC error message is returned.
- If a requested TAP does not exist, a RTEN error message is returned.
Category
Security
Input Format
Input Example
Input Parameters
7.2 CHG-EQPT
(Cisco ONS 15454) The Change Equipment (CHG-EQPT) command performs an in-service upgrade from low density (LD) electrical cards (DS1 [DS1-14, DS1N-14], DS3 [DS3-12, DS3N-12, DS3NE-12], EC1, and DS3XM-6) to high density (HD) electrical cards (DS1/E1-56, DS3/EC1-48, and DS3XM-12).
Usage Guidelines
- For Software Release 6.0 and later, only limited upgrades are supported, such as upgrading one LD DS3-12 card to one HD DS3/EC1-48 card.
- Optical (OC-N) card upgrades and downgrades are supported with the limitations of the MRC-12 and MRC-2.5G-4 cards.
- Compatible equipment types for card upgrade:
–
DS-3/DS3-N/DS3-E/DS3N-E to DS3/EC1-48
–
DS1-14 and DS1N-14 cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 should be upgraded to DS1/E1-56.
–
DS1-14 and DSN-14 cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS1/E1-56.
–
DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 can be upgraded to DS3/EC1-48.
–
DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS3/EC1-48.
–
Two upgradable cards provisioned in a 1:1 protection group cannot be upgraded.
Category
Security
Input Format
CHG-EQPT:[<TID>]:<AID>:<CTAG>::<EQPTTYPE>:[PPMTYPE=PPMTYPE>],
[PPMNUM=<PPMNUM>],[PORTNUM=<PORTNUM>],[PORTRATE=<PORTRATE>];
Input Example
CHG-EQPT::SLOT-14:1::MRC-2.5G-4:PPMTYPE=PPM-1,PPMNUM=1,PORTNUM=1,
PORTRATE=OC48;
Input Parameters
|
|
|
|---|---|
The source access identifier from the “EQPT” section. |
|
The equipment type to be upgraded. The parameter type is EQUIPMENT_TYPE. |
|
Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on even grid |
|
Thermal Multiplex/Demultiplex Passive Unit, spaced at 50 GHz on odd grid |
|
2-port interface card supporting 1000BaseT Ethernet facilities |
|
12-port interface card supporting 100BaseT Ethernet facilities |
|
Four-port interface card supporting 100BaseT Ethernet facilities |
|
The equipment type for FMEC STM1E12 card with 1:3 protection |
|
The passive unit Patch Panel device used to connect upto four 40-SMR2-C cards |
|
16-channels - 1 direction, colorless, omnidirectional add/drop unit. |
|
4-channels, 4-directions, colorless, omnidirectional add/drop unit. |
|
Fast Ethernet switch card used for internal shelf connection |
|
A 4x10G transponder that is capable to operate with multiple bit rates - 10G FC, 10GE, and OC192/STM64 |
|
An interface card that supports one or more STM4 (622 Mbps) optical facilities |
|
An interface card that supports one intermediate range STM4 (622 Mbps) optical facilities |
|
An interface card that supports one long range STM4 (622 Mbps) optical facilities |
|
An interface card that supports one short range STM4 (622 Mbps) optical facilities |
|
An interface card that supports one or more STM64 optical facilities |
|
An interface card that supports multiple STM1 (155 Mbps) optical facilities |
|
An interface card that supports four intermediate range STM1 (155 Mbps) optical facilities |
|
An interface card that supports four short range STM1 (155 Mbps) optical facilities |
|
An interface card that supports six intermediate range STM1 (155 Mbps) ATM optical fibers |
|
An STM1 card which has 8 ports over the lower speed slot with XC-VXL-10G/XC-VXL-2.5G |
|
An interface card that supports four short range STM1 (155 Mbps) POS optical facilities |
|
An interface card that supports one or more STM16 (10 Gbps) optical facilities |
|
An interface card that supports one short range OC-48 (10 Gbps) optical facilities that can be provisioned in any I/O slot |
|
An interface card that supports one short range STM16 (2.5 Gbps) optical facility |
|
An interface card that supports one intermediate range STM16 (10 Gbps) optical facility |
|
An interface card that supports one long range STM16 (10 Gbps) optical facility |
|
An interface card that supports one short range STM16 (10 Gbps) optical facilities |
|
Identifies the pluggable port module type. This parameter can take only one value. |
|
Identifies the pluggable port module number. This parameter is an Integer. |
|
Identifies the port number, which is used on the entity port with PPM. This para meter is an integer. |
|
Identifies the port rate, which is used to specify the port rate of the multi-rate card. |
|