- Preface
- Cisco ONS Documentation Roadmap for Release 10.x.x
- New and Changed Information for Release 10.x.x
- Chapter 1, Overview
- Chapter 2, Provisioning Procedures
- Chapter 3, ACT Commands
- Chapter 4, ALW Commands
- Chapter 5, APPLY Commands
- Chapter 6, CANC Commands and Messages
- Chapter 7, CHG Commands
- Chapter 8, CLR Commands
- Chapter 9, CONN Commands
- Chapter 10, COPY Commands
- Chapter 11, DISC Commands
- Chapter 12, DLT Commands
- Chapter 13, ED Commands
- Chapter 14, ENT Commands
- Chapter 15, EX Commands
- Chapter 16, INH Commands
- Chapter 17, INIT Commands
- Chapter 18, OPR Commands
- Chapter 19, REPT Commands
- Chapter 20, RLS Commands
- Chapter 21, RMV Commands
- Chapter 22, RST Commands
- Chapter 23, RTRV Commands
- Chapter 24, SCHED Commands
- Chapter 25, SET Commands
- Chapter 26, SW Commands
- Chapter 27, TST Commands
- Chapter 28, Access Identifiers
- Chapter 29, Conditions
- Chapter 30, Modifiers
- Chapter 31, TL1 Errors
- 28.1 ALL
- 28.2 AidUnionId
- 28.3 AidUnionId1
- 28.4 BAND
- 28.5 BANDWL
- 28.6 BITS
- 28.7 BLSR
- 28.8 CHANNEL
- 28.9 CHGRP
- 28.10 COM
- 28.11 CrossConnectId
- 28.12 CrossConnectId1
- 28.13 DS1
- 28.14 ENV
- 28.15 EQPT
- 28.16 ETH
- 28.17 FACILITY
- 28.18 FPLINE
- 28.19 IPADDR
- 28.20 LINE
- 28.21 LINEWL
- 28.22 LNKTERM
- 28.23 OPM
- 28.24 OSC
- 28.25 PRSLOT
- 28.26 RFILE
- 28.27 SHELF
- 28.28 STS
- 28.29 SYN
- 28.30 SYN_SRC
- 28.31 SYNC_REF
- 28.32 SYNCSW
- 28.33 UDC
- 28.34 VT
- 28.35 WDMANS
- 28.36 WLEN
- 28.37 CTC Port Numbers and TL1 Aids
Access Identifiers
This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the
for the Cisco ONS 15454, Cisco ONS 15454 M2, and Cisco ONS 15454 M6.
The AID code directs an input command to its intended physical or data entity inside the network element (NE). Equipment modules and facilities are typical examples of entities addressed by the access code. The AIDs in this section apply to the SONET ONS 15454, ONS 15454 M2, and ONS 15454 M6 except where noted.
Note
Access identifiers supported on the Cisco ONS 15454 platform are also supported on Cisco ONS 15454 M2 and Cisco ONS 15454 M6 platforms.
28.1 ALL
AID for CXP port on 100G-LC-C card: AGGR-[SLOT]-[APPM]-[PORT].
AID for fixed trunk on 100G-LC-C card: CHAN-[SLOT]-[PORT].
28.2 AidUnionId
28.3 AidUnionId1
|
|
|
|---|---|
28.4 BAND
(Cisco ONS 15454 only) The BAND AID is used to access Optical Multiplex Section (OMS) layer of optical networking units.
AID for OCH interface of CXP port on 100G-LC-C card: ACHAN-[SLOT]-[PPM]-[PORT].
AID for fixed trunk on 100G-LC-C card: CHAN-[SLOT]-[PORT].
28.5 BANDWL
(Cisco ONS 15454) Band wavelength. Identifies a wavelength channel included in any of the lower layer OMS facilities.
28.6 BITS
AID for building integrated timing supply (BITS).
28.7 BLSR
(ONS 15454) BLSR AIDs are used to access the specific BLSR of the NE.
28.8 CHANNEL
(Cisco ONS 15454 only) Accesses the optical channels (OCH) layer of optical networking units.
28.9 CHGRP
AID for the Channel Group (CHGRP). Table 28-9 lists the CHGRP AIDs and their descriptions.
28.10 COM
|
|
|
28.11 CrossConnectId
AID for CXP port on 100G-LC-C: AGGR-[SLOT]-[APPM]-[PORT].
AID for fixed trunk on 100G-LC-C: CHAN-[SLOT]-[PORT].
28.12 CrossConnectId1
AID for CXP port on 100G-LC-C: AGGR[-{1-50}]-{2-7}-{1}-{1}.
AID for fixed trunk on 100G-LC-C: CHAN-[SLOT]-[PORT].
28.13 DS1
(Cisco ONS 15454 only) Used to access the DS-1 frame layer of the DS3XM. The format is DS1-[SLOT]-[DS3PORT]-[DS1PORT].
28.14 ENV
The environmental AID for the AIC-I cards. “IN” is used for environmental alarms. “OUT” is used for environmental controls.
28.15 EQPT
Equipment AIDs are used to access specific cards.
In the ONS 15454, the OC-48/OC-192 cards are only used in Slots 5, 6, 12, and 13.
AID for CXP port on 100G-LC-C and 10x10G-LC: APPM-[SLOT]-[PPM]-[PORT]
28.16 ETH
Ethernet (ETH) AIDs are used to access the ethernet port. Table 28-9 lists the ETH AIDs and their descriptions.
28.17 FACILITY
( Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) Facility AIDs are used to access specific ports.
ONS 15454 Facility AID format:
- Format for optical and EC1 facilities without PPM: FAC-[SLOT]-[PORT]
- Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
- Format for optical facilities with PPM and PIM: FAC-[SLOT]-[PIM]-[PPM]-[PORT]
- Format for DS1-flavored electrical facilities: FAC-[SLOT]-[PORT]
- Format for DS3-flavored (including DS3i) electrical facilities: FAC-[SLOT]-[PORT]
- Format for packet-over-SONET (POS) ports: VFAC-[SLOT]-[PORT]
- Format for POS ports with PIMs and PPMs: VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
- Format for 100G-LC-C, 10x10G-LC, and CFP-LC cards: VLINE-[SLOT]-[PPM]-[PORT]-[SUBLANE-NO] Sublane Aid for all sublanes
- Format for CXP port on 100G-LC-C card: AGGR-[SLOT]-[APPM]-[PORT].
- Format for SFP+ ports on for 10x10G-LC and CFP-LC cards: VFAC-[SLOT]-[PPM]-[PORT]
28.18 FPLINE
FPLINE AIDs are used on passive OTS ports of MD-48-EVEN/MD-48-ODD passive module. Table 28-18 lists the FPLINE AIDs and their descriptions. The FPLINE AID format is: FPLINE-ID-PORT-DIR-LABEL
28.19 IPADDR
|
|
|
|---|---|
28.20 LINE
(Cisco ONS 15454 only) The LINE AID is used to access the Optical Transport Section (OTS) layer of optical network units. Applicable only to AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O, 32DMX-O, 40-SMR1-C, 40-SMR2-C, and 80-WXC-C cards.
The format is LINE-[SLOT]-[PORT]-[DIRECTION].
28.21 LINEWL
Line wavelength. Identifies a wavelength channel included in any of the lower layer OTS facilities.
28.22 LNKTERM
Link termination AIDs are used to access the termination points of a provisionable patchcord.
28.23 OPM
OPM AIDs represent the single wavelength inside an optical power monitoring object.
28.24 OSC
(Cisco ONS 15454 only) OSC AIDs are used to access the OSC of the NE.
|
|
|
|---|---|
All of the OSCs of the NE. The ALL AID applies to the retrieve-only commands. |
|
RINGID is a string of up to six characters. Valid characters are [A–Z,0–9] (case insensitive). |
28.25 PRSLOT
(Cisco ONS 15454 only) Valid protection slots for the electrical cards.
|
|
|
|---|---|
Indicates there is no protection group. Used when trying to delete a protection group. |
|
28.26 RFILE
(ONS 15454) File transfer type.
|
|
|
28.27 SHELF
(ONS 15454) Identifies a shelf within a node. SHELF is applicable only to nodes that are set to MULTISHELF or MULTISHELFETH mode.
|
|
|
28.28 STS
- STS AID format for optical and EC1 facilities without PPM: STS-[SLOT]-[PORT]-[STS]
- STS AID format for optical facilities with PPMs: STS-[SLOT]-[PPM]-[PORT]-[STS]
- STS AID format for optical facilities with PIMs and PPMs: STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
- STS AID format for DS1 electrical facilities: STS-[SLOT]-[STS]
- STS AID format for DS3 (except DS3i) electrical facilities: STS-[SLOT]-[PORT]-[STS]
- STS AID format for DS3i electrical facilities: STS-[SLOT]-[STS]
- STS AID format for G1K-4 card Gigabit Ethernet (GIGE) facilities: FAC-[SLOT]-[PORT]
28.29 SYN
|
|
|
|---|---|
28.30 SYN_SRC
28.31 SYNC_REF
(Cisco ONS 15454, ONS 15454 M2, and ONS 15454 M6) Synchronization AIDs.
|
|
|
|---|---|
Equivalent to a combination of SYNC-ALL, BITS-1 and BITS-2. This AID is valid only for the commands RTRV-SYNCN, RTRV-ALM-SYNCN, and RTRV-COND-SYNCN. |
|
28.32 SYNCSW
New synchronization reference that will be used.
|
|
|
|---|---|
Internal clock. The INT value is only applied for the SYNC-NE AID on the OPR-SYNCSW command. |
|
28.33 UDC
(ONS 15454) UDC AIDs for F-UDC and DCC-UDC channels on the AIC-I card.
28.34 VT
(ONS 15454) Virtual tributary.
- VT1 AID format for optical and EC1 facilities without PPM: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
- VT1 AID format for optical facilities with PPM: VT1-[SLOT]-[PPM]-[PORT]-[STS]-[VTG]-[VTN]
- VT1 AID format for DS1 electrical facilities: VT1-[SLOT]-[STS]-[VTG]-[VTN]
- VT1 AID format for DS3 electrical facilities: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
|
|
|
|---|---|
Applies to RTRV-only commands. For example, the RTRV-VT and RTRV-VT1 with ALL AIDs return all VT1 interfaces on the node. |
|
28.35 WDMANS
(Cisco ONS 15454 only) This AID is used to access the Wavelength Division Multiplexing (WDM) automatic optical node setup (AONS) application of the NE.
|
|
|
|---|---|
28.36 WLEN
(Cisco ONS 15454 only) This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line), the wavelengths contained are all the available in the node (currently 32). If the facility is of type OCH (CHAN), the wavelength is just one and it is the same of the correspondent wavelength customized for that channel.
28.37 CTC Port Numbers and TL1 Aids
|
|
|
|
|
|---|---|---|---|
Feedback