THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
| Affected Product Name | Description | Comments | |
|---|---|---|---|
| N9336C-SE1 | Nexus 9300 S1 Series, 36p 40/100G QSFP28 | Only N9336C-SE1 with IO FPGA version that is 0x24 or lower is affected by this problem. To check version of IO FPGA use show version module 1 epld. |
| Affected Software Product | Affected Release | Affected Release Number | Comments |
|---|---|---|---|
| NX-OS System Software | 10 | 10.6(1), 10.6(2), 10.6(3), 10.6(4) | IO FPGA versions 0x24 and lower are affected. Use show version module 1 epld to record installed EPLD revisions |
| Defect ID | Headline |
| CSCwu88949 | N9336C-SE1 -- Intermittent System Hang with No Access to MGMT/Console nor Inband |
Cisco N9336C-SE1 Switches may intermittently enter an unresponsive freeze or lock up during normal operation. Console access, remote management, and in-band connectivity become unavailable. Front-panel ports might be nonoperational during the failure, resulting in a service outage.
The failure interval varies. Events might occur after days or weeks of operation. There is no confirmed specific operational trigger.
Only power cycling the switch restores operation. The issue may recur until the corrective electronic programmable logic device (EPLD) update is installed.
An affected Cisco N9336C-SE1 Switch may stop responding during operation. Customers may observe the following:

A fixed interval, such as 14 days of uptime, is not a required symptom. Identification should consider the product ID (PID), simultaneous loss of access, service impact, and recovery behavior.
Workaround
There is no workaround to prevent this issue from happening. To recover, power cycle the affected switch to recover from the unresponsive state. Power cycling does not prevent recurrence.
Solution
Upgrade the IO FPGA on the affected Cisco N9336C-SE1 Switch to version 0x25 or later. The EPLD image that contains the fix is n9000-epld-s1.10.6.4.M.img. This EPLD image is supported on the following Cisco NX-OS Software releases:
The EPLD image can be downloaded at the following link: https://software.cisco.com/download/home/286341356/type/282253564/release/10.6(4).
The EPLD upgrade is disruptive. The switch reloads automatically at the end of the upgrade. Schedule the upgrade during a maintenance window.
Future releases, such as 10.6.(5)M and10.7(1)F, will already have the fix integrated into the image. Therefore, a separate EPLD upgrade will not be needed for those releases.
To install EPLD using Cisco Nexus Dashboard, use the following steps:
For the complete preparation and upgrade procedure, see Managing Your Fabric Software in the Cisco Nexus Dashboard upgrade guide.
To manually install the EPLD, use the following steps:
show module show version show version module 1 epld
install epld bootflash:n9000-epld-s1.10.6.4.M.img module all
The IO FPGA must report 0x25 or higher. Check both the Version and Flashed Version columns.show version module 1 epld
The following example shows the EPLD upgrade:
N9336C-SE1# show version module 1 epld
Module 1:
EPLD Device Version Flashed Version
----------------------------------------------------------------
MI FPGA 0x10 0x10
IO FPGA 0x22 0x22
N9336C-SE1# install epld bootflash:n9000-epld-s1.10.6.4.M.img module all
Compatibility check:
Module Type Upgradable Impact Reason
------ ----------------- ---------- ---------- ------
27 SUP Yes disruptive Module Upgradable
Retrieving EPLD versions.... Please wait.
Images will be upgraded according to following table:
Module Type EPLD Running-Version Flashed-Version New-Version Upg-Required
------ ---- -------- --------------- -------------- ----------- ------------
27 SUP MI FPGA 0x10 0x10 0x10 No
27 SUP IO FPGA 0x22 0x22 0x25 Yes
The above modules require upgrade.EPLD Upgrade may result in multiple modules going offline.
The switch will be reloaded at the end of the upgrade
Do you want to continue (y/n) ? [n] y
Proceeding to upgrade Modules.
Starting Module 27 EPLD Upgrade
Module 27 : IO FPGA [Programming] : 100.00% ( 64 of 64 sectors)
Module 27 EPLD upgrade is successful..
Module Type Upgrade-Result
------ ------------------ --------------
27 SUP Success
Module 27 EPLD upgrade is successful.
Module Type Upgrade-Result
------ ------------------ --------------
27 SUP Success
Reseting Active SUP (Module 27) FPGAs. Please wait...
Reload in 10 seconds .....
N9336C-SE1#
The following example shows the fixed IO FPGA version after the upgrade:
N9336C-SE1# show version module 1 epld Module 1: EPLD Device Version Flashed Version ---------------------------------------------------------------- MI FPGA 0x10 0x10 IO FPGA 0x25 0x25 N9336C-SE1#
IO FPGA must be 0x25 or higher. MI FPGA does not need to be upgraded to resolve the problem.
The affected PID is N9336C-SE1. The model may appear as N9336C-SE1 in CLI output. Confirm the device identity and installed versions while the switch is responsive or after recovery using the following commands:
show module show version show version module 1 epld
Check the IO FPGA revision using the show version module 1 epld command. An IO FPGA revision below 0x25 does not include the required correction. The IO FPGA must be 0x25 or higher to meet the fixed version requirement.
Platform and Module Identification
The following example uses show module to indicate that the device PID is N9336C-SE1 and, therefore, the device may be affected.
N9336C-SE1# show module Mod Ports Module-Type Model Status --- ----- ------------------------------------------------ --------------------- -------- 1 36 36x40/100G QSFP28 Ethernet Module N9336C-SE1 ok 27 0 Virtual Supervisor Module N9336C-SE1 active * Mod Sw Hw Slot --- ----------------------- ------ ---- 1 10.6(3) 1.0 NA 27 10.6(3) 1.0 VSUP Mod MAC-Address(es) Serial-Num --- -------------------------------------- ---------- 1 XX-XX-XX-XX-XX-XX to XX-XX-XX-XX-XX-XX XXXXXXXXXXX 27 XX-XX-XX-XX-XX-XX to XX-XX-XX-XX-XX-XX XXXXXXXXXXX Mod Online Diag Status --- ------------------ 1 Pass 27 Pass * this terminal session
EPLD Version Identification
In the following example, the IO FPGA version is 0x22, which is below the required fixed version, 0x25. Therefore, the device is affected by this problem.
N9336C-SE1# show version module 1 epld Module 1: EPLD Device Version Flashed Version ---------------------------------------------------------------- MI FPGA 0x10 0x10 IO FPGA 0x22 0x22
| Version | Description | Section | Date |
| 1.0 | Initial Release | — | 2026-NOV-20 |
For further assistance or for more information about this field notice, contact the Cisco Technical Assistance Center (TAC) using one of the following methods: