Specifications

Chassis Specifications

Catalyst 9404R Switch Chassis Specifications

Table 1. Physical Specifications of the Chassis

Item

Specification

Dimensions (H x W x D)

10.47 x 17.3 x 16.3 inches (26.53 x 43.94 x 41.40 cms)

Rack units (RU1)

6 RU

Weight

Chassis with fan tray—39.0 lbs (17.2 kgs)

1 The chassis height is measured in rack units (RU or just U), where 1 RU or 1 U equals 1.75 in (44.45 mm).
Table 2. Environmental Specifications of the Chassis

Item

Specification

Ambient temperature and altitude for normal operations2

  • 23° to 113°F (-5 to +45ºC), up to 6,000 feet (1800 m)

  • 23° to 104°F (-5 to +40ºC), up to 10,000 feet (3000 m)

Ambient temperature and altitude for short-term3 exceptional conditions

  • 23° to 131°F (-5 to +55ºC), up to 6,000 feet (1800 m)

  • 23° to 122°F (-5 to +50ºC), up to 10,000 feet (3000 m)

Nonoperating and storage: -40° to 167°F (-40° to 75°C)

Nonoperating and storage temperature

-40° to 167°F (-40° to 75°C)

Thermal transition

Hot to cold—at a maximum rate of 86°F (30°C) per hour

Cold to hot—at maximum rate of 204.8°F (96°C) per hour

Humidity (RH), ambient (noncondensing)

Operating, nonoperating and storage —10 to 95 percent

Altitude (operating and nonoperating)

-60 to 3000m

Sound pressure level (LpAD) and sound power level (LwAD)

LpAD—57 dBA

LwAD—no greater than 7.2 Bels

This is with four power supply modules installed and delivering 50 percent of rated output power; measured according to International Organization for Standardization (ISO) 7779 and declared according to ISO 9296.

Airflow

  • Chassis (airflow direction when facing the front of the chassis)

    • Standard Rack Mount (With or without shelf brackets)—Right to left

    • NEBS-Compliant Rack Mount—Front to back

  • Power supply—Front to back

Shock

Operating—5G 11ms (Half-sine)

Nonoperating and storage— 15G 11ms (Half-sine)

Sine Vibration

  • Operating— 0.15G (10Hz-500Hz)

  • Nonoperating and storage— 0.8G (10Hz-500Hz)

Random Vibration (Operating)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

0.1 [(m/s²)²]/Hz

(0.001 g²/Hz)

-

100 – 200 Hz

-

24 db /octave

Random Vibration (Nonoperating and Storage)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

1.0 [(m/s²)²]/Hz*

(0.01 g²/Hz)

-

100 – 200 Hz

-

24 db /octave

2 Minimum ambient temperature for cold startup is 0ºC
3 Short-term exceptional conditions are for no longer than a one-year period of—96 consecutive hours, or 360 hours total, or 15 occurrences.

Catalyst 9407R Switch Chassis Specifications

Table 3. Physical Specifications of the Chassis

Item

Specification

Dimensions (H x W x D)

17.41 x 17.30 x 16.30 inches (44.22 x 43.94 x 41.40 cms)

Rack units (RU4)

10 RU

Weight

Chassis with fan tray—63.0 lb (28.58 kg)

4 The chassis height is measured in rack units (RU or just U), where 1 RU or 1 U equals 1.75 in (44.45 mm).
Table 4. Environmental Specifications of the Chassis

Item

Specification

Ambient temperature and altitude for normal operations5

  • 23° to 113°F (-5 to +45ºC), up to 6,000 feet (1800 m)

  • 23° to 104°F (-5 to +40ºC), up to 10,000 feet (3000 m)

Ambient temperature and altitude for short-term6 exceptional conditions

  • 23° to 131°F (-5 to +55ºC), up to 6,000 feet (1800 m)

  • 23° to 122°F (-5 to +50ºC), up to 10,000 feet (3000 m)

Nonoperating and storage: -40° to 167°F (-40° to 75°C)

Nonoperating and storage temperature

-40° to 167°F (-40° to 75°C)

Thermal transition

Hot to cold—at a maximum rate of 86°F (30°C) per hour

Cold to hot—at maximum rate of 204.8°F (96°C) per hour

Humidity (RH), ambient (noncondensing)

Operating, nonoperating and storage —10 to 95 percent

Altitude (operating and nonoperating)

-60 to 3000m

Sound pressure level (LpAD) and sound power level (LwAD)

LpAD—58 dBA

LwAD—no greater than 7.7 Bels

This is with eight power supply modules installed and delivering 50 percent of rated output power; measured according to International Organization for Standardization (ISO) 7779 and declared according to ISO 9296.

Airflow

  • Chassis (airflow direction when facing the front of the chassis)

    • Standard Rack Mount (With or without shelf brackets)—Right to left

    • NEBS-Compliant Rack Mount—Front to back

  • Power supply—Front to back

Shock

Operating—5G 11ms (Half-sine)

Nonoperating and storage— 15G 11ms (Half-sine)

Sine Vibration

  • Operating— 0.15G (10Hz-500Hz)

  • Nonoperating and storage— 0.8G (10Hz-500Hz)

Random Vibration (Operating)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

0.1 [(m/s²)²]/Hz

(0.001 g²/Hz)

-

100 – 200 Hz

-

24 db /octave

Random Vibration (Nonoperating and Storage)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

1.0 [(m/s²)²]/Hz*

(0.01 g²/Hz)

-

100 – 200 Hz

-

24 db /octave

5 Minimum ambient temperature for cold startup is 0ºC
6 Short-term exceptional conditions are for no longer than a one-year period of—96 consecutive hours, or 360 hours total, or 15 occurrences.

Catalyst 9410R Switch Chassis Specifications

Table 5. Physical Specifications of the Chassis

Item

Specification

Dimensions (H x W x D)

22.61 x 17.30 x 16.30 in. (57.43 x 43.94 x 41.40 cm)

Rack units (RU7)

13 RU

Weight

Chassis with fan tray—65.0 lb (29.48 kg)

7 The chassis height is measured in rack units (RU or just U), where 1 RU or 1 U equals 1.75 in (44.45 mm).
Table 6. Environmental Specifications of the Chassis

Item

Specification

Ambient temperature and altitude for normal operations8

  • 23° to 113°F (-5 to +45ºC), up to 6,000 feet (1800 m)

  • 23° to 104°F (-5 to +40ºC), up to 10,000 feet (3000 m)

Ambient temperature and altitude for short-term conditions9 exceptional conditions

  • 23° to 131°F (-5 to +55ºC), up to 6,000 feet (1800 m)

  • 23° to 122°F (-5 to +50ºC), up to 10,000 feet (3000 m)

Nonoperating and storage

-40° to 167°F (-40° to 75°C)

Thermal transition

Hot to cold—at a maximum rate of 86°F (30°C) per hour

Cold to hot—at maximum rate of 204.8°F (96°C) per hour

Humidity (RH), ambient (noncondensing)

Operating, nonoperating and storage —10 to 95 percent

Altitude (operating and nonoperating)

-60 to 3000m

Sound pressure level (LpAD) and sound power level (LwAD)

LpAD—60 dBA

LwAD—no greater than 7.8 Bels

This is with eight power supply modules installed and delivering 50 percent of rated output power; measured according to International Organization for Standardization (ISO) 7779 and declared according to ISO 9296.

Airflow

  • Chassis (airflow direction when facing the front of the chassis)

    • Standard Rack Mount (With or without shelf brackets)—Right to left

    • NEBS-Compliant Rack Mount—Front to back

  • Power supply—Front to back

Shock

Operating—5G 11ms (Half-sine)

Nonoperating and storage— 15G 11ms (Half-sine)

Sine Vibration

  • Operating— 0.15G (10Hz-500Hz)

  • Nonoperating and storage— 0.8G (10Hz-500Hz)

Random Vibration (Operating)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

0.1 [(m/s²)²]/Hz

(0.001 g²/Hz)

-

100 – 200 Hz

-

24 db /octave

Random Vibration (Nonoperating and Storage)

Spectral Break Point Frequencies

Acceleration Spectral Density

Slope

2.5 – 5 Hz

-

6 db /octave

5 – 100 Hz

1.0 [(m/s²)²]/Hz*

(0.01 g²/Hz)

-

100 – 200 Hz

-

24 db /octave

8 Minimum ambient temperature for cold startup is 0ºC
9 Short-term exceptional conditions are for no longer than a one-year period of—96 consecutive hours, or 360 hours total, or 15 occurrences.

Power Supply Specifications

2100-W AC and 2100-W ACT-Input Power Supply Specifications

The following table lists specifications for the 2100 W AC and 2100 W ACT input power supply:

Table 7. 2100-W AC and 2100-W ACT-Input Power Supply Specifications
Specification Description

AC-input type

Wide-ranging input with power factor correction.

Note

 
Power factor correction is a standard feature on AC-input power supplies. Power factor correction reduces the reactive component in the source AC current, allowing higher power factors (0.90 minimum at loads equal to or greater than 20 percent of maximum loads, and 0.95 minimum at 2100W maximum loads, at 115/230 VAC nominal AC input voltages) and lower harmonic current components.

AC-input voltage

Low-line (115 VAC nominal)—85 VAC (min) to 132 VAC (max)

High-line (230 VAC nominal)—180 VAC (min) to 264 VAC (max)

AC-input current

11.44 A at 100 VAC (950 W output)

11.44 A at 200 VAC (2112 W output)

AC-input frequency

50/60Hz nominal (47 to 63Hz full range)

Branch circuit requirement

Each chassis power supply should have its own dedicated, fused-branch circuit:

  • North America—15 A.

  • International—Circuits sized to local and national codes.

  • All AC power supply inputs are fully isolated.

    • Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B.

    • For high-line operation, the power supply operates with the line conductor wired to an source AC phase, and the Neutral conductor wired either to a Neutral, single-phase power system, or to another source AC phase as long as the net input voltage is in the range of 180 to 264 VAC.

Power supply output capacity

For 55 VDC output – 940W at 115 VAC; 2102W at 230 VAC

For 3.3VDC output – 10W at 115 VAC; 10 W at 230 VAC

Power supply output

  • 100 to 120 VAC operation

    • 3.0A @ 3.3 V

    • 17.09A @ 55V

  • 200 to 240 VAC operation

    • 3.0A @ 3.3 V

    • 38.21A @ 55V

Output holdup time

20 ms minimum.

kVA rating10

2112W (total output power) or 2246.8 kVA (high-line operation)

Heat dissipation (in British Thermal Units (BTU))

C9400-PWR-2100AC

  • For 2112W—460.0 BTU per hour

  • For 950W—244.0 BTU per hour

C9400-PWR-2100ACT

  • For 2112W—295.0 BTU per hour

  • For 950W—186.0 BTU per hour

Weight

C9400-PWR-2100AC 5.0 lb (2.3 kg)

C9400-PWR-2100ACT 5.0 lb (2.3 kg)

10 The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch

2100-W Power Supply Module AC Power Cords

The following table lists the specifications for the AC power cords that are available for the 2100 W AC-input power supply. The table also includes references to power cord illustrations.


Note


All 2100 W power supply power cord:

  • Lengths range from 9.84 – 14 feet (3.0 – 4.293 meters); with most cord lengths between 13 and 14 feet (4.013 and 4.293 meters)

  • Have an IEC60320/C19 appliance connector at one end.

    Figure 1. IEC60320/C19 Appliance Connector

Table 8. 2100 W Power Supply AC Power Cords

Locale

Part Number

Cordset Rating

AC Source Plug Type

Argentina

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 2. CAB-I309-C19-INTL= (Argentina)

Australia

CAB-AC-16A-AUS

16 A, 250 VAC

Figure 3. CAB-AC-16A-AUS= (Australia)

Europe

CAB-CEE77-C19-EU

16 A, 250 VAC

Figure 4. CAB-CEE77-C19-EU= and CAB-I309-C19-INTL= (Europe)

CAB-I309-C19-INTL

20 A, 250 VAC

India

CAB-SABS-C19-IND

16 A, 250 VAC

Figure 5. CAB-SABS-C19-IND= (India)

International

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 6. CAB-I309-C19-INTL= (International)

Israel

CAB-S132-C19-ISRL

16 A, 250 VAC

Figure 7. CAB-S132-C19-ISRL= (Israel)

Italy

CAB-C2316-C19-IT

16 A, 250 VAC

Figure 8. CAB-C2316-C19-IT= (Italy)

Japan, North America (Nonlocking Plug) 200 to 240 VAC Operation

CAB-US620P-C19-US

20 A, 250 VAC

Figure 9. CAB-US620P-C19-US= (Japan, North America - Nonlocking)

Japan, North America (Locking Plug) 200 to 240 VAC Operation

CAB-L620P-C19-US

20 A, 250 VAC

Figure 10. CAB-L620P-C19-US= ( Japan, North America - Locking )

North America

CAB-US515P-C19-US

125VAC, 15A

Figure 11. CAB-US515P-C19-US=(North America)

North America

CAB-US520-C19-US

20 A, 125 VAC

Figure 12. CAB-US520-C19-US= (North America)

South Africa

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 13. CAB-I309-C19-INTL= (South Africa)

United Kingdom

CAB-BS1363-C19-UK

250 VAC, 13 A

Figure 14. CAB-BS1363-C19-UK=(United Kingdom)

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 15. CAB-I309-C19-INTL= (International)

UPS 220V

CAB-C19-CBN

20 A, 250 VAC

Figure 16. 130923

3200-W AC and 3200-W ACT-Input Power Supply Specifications

The following table lists specifications for the 3200 W AC and 3200 W ACT input power supply:

Table 9. 3200 W AC and 3200 W ACT-Input Power Supply Specifications
Specification Description

AC-input type

Wide-ranging input with power factor correction.

Note

 
Power factor correction is a standard feature on AC-input power supplies. Power factor correction reduces the reactive component in the source AC current, allowing higher power factors (0.90 minimum at loads equal to or greater than 20 percent of maximum loads, and 0.95 minimum at 3200W maximum loads, at 115/230 VAC nominal AC input voltages) and lower harmonic current components.

AC-input voltage

Low-line (115 VAC nominal)—85 VAC (min) to 132 VAC (max)

High-line (230 VAC nominal)—180 VAC (min) to 264 VAC (max)

AC-input current

17.6 A at 100 VAC (1570 W output)

17.6 A at 200 VAC (3200 W output)

AC-input frequency

50/60Hz nominal (47 to 63Hz full range)

Branch circuit requirement

Each chassis power supply should have its own dedicated, fused-branch circuit:

  • North America—20 A.

  • International—Circuits sized to local and national codes.

  • All AC power supply inputs are fully isolated.

    • Source AC can be out of phase between multiple power supplies in the same chassis, which means that PS1 can be operating from phase A and PS2 can be operating from phase B.

    • For high-line operation, the power supply operates with the line conductor wired to an source AC phase, and the Neutral conductor wired either to a Neutral, single-phase power system, or to another source AC phase as long as the net input voltage is in the range of 180 to 264 VAC.

Power supply output capacity

For 55 VDC output—1560 W at 115 VAC; 3190 W at 230 VAC

For 3.3VDC output—10 W at 115 VAC; 10 W at 230 VAC

Power supply output

  • 100 to 120 VAC operation

    • 3.0A @ 3.3 V

    • 28.36 A @ 55V

  • 200 to 240 VAC operation

    • 3.0A @ 3.3 V

    • 58 A @ 55V

Output holdup time

20 ms minimum.

kVA rating11

3200W (total output power ) or 3478.3 kVA (high-line operation).

Heat dissipation (in British Thermal Units (BTU))

C9400-PWR-3200AC

  • For 3200W—948.86 BTU per hour

  • For 1570W—594.85 BTU per hour

C9400-PWR-3200ACT

  • For 3200W—948.87 BTU per hour

  • For 1570W—465.54 BTU per hour

Weight

C9400-PWR-3200 AC—5.0 lb (2.3 kg)

C9400-PWR-3200 ACT—4.0 to 5.0 lb (1.81 kg to 2.3 kg)12

11 The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch
12 The weight of the power supply module varies depending on the vendor.

3200-W Power Supply Module AC Power Cords

The following table lists the specifications for the AC power cords that are available for the 3000 W AC-input power supply. The table also includes references to power cord illustrations.


Note


All 3200 W power supply power cord:

  • Lengths range from 9.84 – 14 feet (3.0 – 4.293 meters); with most cord lengths between 13 and 14 feet (4.013 and 4.293 meters)

  • Have an IEC60320/C19 appliance connector at one end.

    Figure 17. IEC60320/C19 Appliance Connector

Table 10. 3200 W Power Supply AC Power Cords

Locale

Part Number

Cordset Rating

AC Source Plug Type

Argentina

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 18. CAB-I309-C19-INTL= (Argentina)

Australia

CAB-AC-16A-AUS

16 A, 250 VAC

Figure 19. CAB-AC-16A-AUS= (Australia)

China

CAB-9K16A-CH

16 A, 250 VAC

Figure 20. CAB-9K16A-CH= (China)

Europe

CAB-CEE77-C19-EU

16 A, 250 VAC

Figure 21. CAB-CEE77-C19-EU= and CAB-I309-C19-INTL= (Europe)

CAB-I309-C19-INTL

20 A, 250 VAC

India

CAB-SABS-C19-IND

16 A, 250 VAC

Figure 22. CAB-SABS-C19-IND= (India)

International

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 23. CAB-I309-C19-INTL= (International)

Israel

CAB-S132-C19-ISRL

16 A, 250 VAC

Figure 24. CAB-S132-C19-ISRL= (Israel)

Italy

CAB-C2316-C19-IT

16 A, 250 VAC

Figure 25. CAB-C2316-C19-IT= (Italy)

Japan, North America (Nonlocking Plug) 200 to 240 VAC Operation

CAB-US620P-C19-US

20 A, 250 VAC

Figure 26. CAB-US620P-C19-US= (Japan, North America - Nonlocking)

Japan, North America (Locking Plug) 200 to 240 VAC Operation

CAB-L620P-C19-US

20 A, 250 VAC

Figure 27. CAB-L620P-C19-US= ( Japan, North America - Locking )

North America

CAB-US520-C19-US

20 A, 125 VAC

Figure 28. CAB-US520-C19-US= (North America)

South Africa

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 29. CAB-I309-C19-INTL= (South Africa)

United Kingdom

CAB-I309-C19-INTL

20 A, 250 VAC

Figure 30. CAB-I309-C19-INTL= (United Kingdom)

UPS 220V

CAB-C19-CBN

20 A, 250 VAC

Figure 31. 130923

3200-W DC-Input Power Supply Specifications

The following table lists the specifications for a 3200-W DC-input power supply module:

Table 11. 3200-W DC-Input Power Supply Specifications
Specification Description

DC-input voltage

-40 to -72 VDC, with extended range of up to -75 VDC

DC-input current

Nominal: 36 A per DC input (72 A total) at -48 to -60 VDC input

Maximum: 44 A per DC input at -40 VDC input

Power supply output capacity

For 55 VDC output—3190 W

For 3.3VDC output—10 W

Output holdup time

8 ms

Temperature

  • Steady State Operating:

    -5 to +55 °C (45 °C at 13,123 feet) full load and -40 to -75 VDC

    -5 to +60 °C (50 °C at 13,123 feet) half load and -40 to -75 VDC

  • Nonoperating: -40 to +85 °C

Humidity

  • Operating: 10 to 90 percent, noncondensing

  • Nonoperating: 5 to 95 percent, noncondensing

Thermal Shock

  • Operating: -5 to +55 °C at 2.5 °C per minute

  • Nonoperating: -25 to +70 °C with a changeover time of three minutes

Altitude

  • Operating: -500 to 13,123 feet over allowable temperature range (-5 to +55 °C) and full load, derating 1.4 °C per 1000 feet above 6,000 feet

    Note

     

    The operating altitude in China is 6,561.6 ft. (2000 m) maximum

  • Nonoperating: -1,000 to 50,000 feet over allowable temperature range

Heat dissipation (in British Thermal Units [BTU])

For 3200W—950 BTU per hour

Weight

6.61 lb (3.0 kg)

Chassis and Module Power and Heat Values

The following tables provide the power and heat dissipation data. Unless otherwise noted, the information in the tables is measured under fully loaded conditions (transceivers installed).


Note


DC output power is the output from the power supply (internal to the system). The AC-input power is the input from the outlet to the power supply. The percentage difference between the two values is the efficiency of the power supply.


Table 12. Power Requirements and Heat Dissapation - Fan Tray

PID

AC-Input Power in Watts

(Power Allocated)

DC-Output in Watts

(Power Requested)

Current @ 90V

Current @ 120V

Current @ 180V

Current @ 240V

Heat Diss. in BTU / hr.

C9404-FAN

411

370

4.57

3.43

2.28

1.71

1403

C9407-FAN

600

540

6.67

5.00

3.33

2.50

2047

C9410-FAN

778

700

8.64

6.48

4.32

3.24

2654

Table 13. Power Requirements and Heat Dissapation - Supervisor Modules

PID

AC-Input Power in Watts

(Power Allocated)

DC-Output in Watts

(Power Requested)

Current @ 90V

Current @ 120V

Current @ 180V

Current @ 240V

Heat Diss. in BTU / hr.

C9400-SUP-1

444

400

4.94

3.70

2.47

1.85

1516

C9400-SUP-1XL

444

400

4.94

3.70

2.47

1.85

1516

C9400-SUP-1XL-Y

444

400

4.94

3.70

2.47

1.85

1516

C9400X-SUP-2

722

650

8.02

6.02

4.01

3.01

2464

C9400X-SUP-2XL

722

650

8.02

6.02

4.01

3.01

2464

Table 14. Power Requirements and Heat Dissipation— Line Cards

PID

AC-Input Power in Watts

(Power Allocated)

DC-Output in Watts

(Power Requested)

Current @ 90V

Current @ 120V

Current @ 180V

Current @ 240V

Heat Diss. in BTU / hr.

C9400-LC-12QC

222

200

2.47

1.85

1.23

0.93

758

C9400-LC-24S

133

120

1.48

1.11

0.74

0.56

455

C9400-LC-24XS

222

200

2.47

1.85

1.23

0.93

758

C9400-LC-24XY

222

200

2.47

1.85

1.23

0.93

758

C9400-LC-48H

72

65

0.80

0.60

0.40

0.30

246

C9400-LC-48HN

194

175

2.16

1.62

1.08

0.81

663

C9400-LC-48HX

300

270

3.33

2.50

1.67

1.25

1024

C9400-LC-48P

72

65

0.80

0.60

0.40

0.30

246

C9400-LC-48S

189

170

2.10

1.57

1.05

0.79

644

C9400-LC-48T

72

65

0.80

0.60

0.40

0.30

246

C9400-LC-48TX

300

270

3.33

2.50

1.67

1.25

1024

C9400-LC-48U

72

65

0.80

0.60

0.40

0.30

246

C9400-LC-48UX

267

240

2.96

2.22

1.48

1.11

910

C9400-LC-48XS

278

250

3.09

2.31

1.54

1.16

948

Weight Specifications

The total weight of a fully configured chassis will depend on the type of chassis, the number of modules, and power supplies installed. Use the corresponding weights in the tables below to arrive at the total chassis weight for your hardware configuration.

Chassis Weights

PID (add "=" for spare)

Weight (Chassis with Fan Tray)

C9404R

39.0 lb (17.2 kg)

C9407R

63.0 lb (28.58 kg)

C9410R

65.0 lb (29.48 kg)

Supervisor Module Weights

PID (add "=" for spare)

Weight

C9400-SUP-1

9.9 lb (4.5 kg)

C9400-SUP-1XL

9.9 lb (4.5 kg)

C9400-SUP-1XL-Y

9.9 lb (4.5 kg)

C9400X-SUP-2

10.5 lb (4.78 kg)

C9400X-SUP-2XL

10.5 lb (4.78 kg)

Line Card Weights

PID (add "=" for spare)

Weight

C9400-LC-12QC

7.7 lb (3.49kgs)

C9400-LC-24S

5.5 lb (2.49 kg)

C9400-LC-24XS

6.9 lb (3.1 kg)

C9400-LC-24XY

7.4 lb (3.37kgs)

C9400-LC-48H

6.9 lb (3.13 kg)

C9400-LC-48HN

8.5 lb (3.85 kg)

C9400-LC-48HX

8.4 lb (3.81 kg)

C9400-LC-48P

6.6 lb (3.0 kg)

C9400-LC-48S

6.5 lb (2.94 kg)

C9400-LC-48T

6.2 lb (2.82 kg)

C9400-LC-48TX

7.6 lb (3.47 kg)

C9400-LC-48U

6.7 lb (3.0 kg)

C9400-LC-48UX

8.3 lb (3.8 kg)

C9400-LC-48XS

8.1 lb (3.67 kg)

Power Supply Module Weights

PID (add = for spare)

Weight

C9400-PWR-2100AC

5.0 lb (2.3 kg)

C9400-PWR-2100ACT

5.0 lb (2.3 kg)

C9400-PWR-3200DC

6.6 lb (3.0 kg)

C9400-PWR-3200AC

5.0 lb (2.3 kg)

C9400-PWR-3200ACT

4 to 5 lb (1.8 kg to 2.3 kg)13

13 The weight of the power supply module varies depending of the vendor.

Blank Covers

PID (add = for spare)

Weight

C9400-S-BLANK

(Cisco Catalyst 9400 Series Slot Blank Cover)

3.4 lb (1.54 kg)

C9400-PWR-BLANK

(Cisco Catalyst 9400 Series Power Supply Blank Cover)

0.14 lb (0.06 kg)