NTP-L19 Replacing the Air Filter of the NCS 2002 Shelf Assembly
|
Purpose |
This procedure replaces the air filter of the NCS 2002 shelf assembly. |
|
Tools/Equipment |
New air filter |
|
Prerequisite Procedures |
|
|
Required/As Needed |
As Needed |
|
Onsite/Remote |
Remote |
|
Security Level |
Provisioning or higher |
![]() Note |
The air filters are single-use only. They must not be cleaned and reused. This is a Telcordia NEBS requirement, GR-63-CORE Issue 4. |
![]() Note |
Air filters must be inspected every quarter after the initial six month inspection. If they are dirty or clogged with dust, they must be replaced with a new air filter. Air filters are consumable items and replacement air filters must be ordered separately. You may contact TAC for assistance in identifying the correct air filter PID to order. We recommend having spare air filters in stock. |
Procedure
|
Step 1 |
Untighten the screw on the air-filter (see the figure below). ![]()
|
||||
|
Step 2 |
Extract the air filter from the shelf assembly as shown in the figure below. ![]()
|
||||
|
Step 3 |
Separate the cable guides from the air filter as shown in the figure below. ![]() |
||||
|
Step 4 |
Replace the air filter with a new one if the air filter is dirty or clogged with dust. |
||||
|
Step 5 |
Attach the cable guide and insert the air filter into the shelf assembly.
|
||||
|
Step 6 |
Tighten the screw on the air-filter. Stop. You have completed this procedure. |