Cisco APIC Container Plug-in Release Notes, Release 5.1(3)

Available Languages

Download Options

  • PDF
    (278.9 KB)
    View with Adobe Reader on a variety of devices
Updated:March 1, 2022

Bias-Free Language

The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.

Available Languages

Download Options

  • PDF
    (278.9 KB)
    View with Adobe Reader on a variety of devices
Updated:March 1, 2022
 

 

 

Introduction

This document describes the features, bugs, and limitations for the Cisco Application Policy Infrastructure Controller (APIC) Container Plug-in.

The Cisco Application Centric Infrastructure (ACI) Container Network Interface (CNI) Plug-in provides network services to Kubernetes, Red Hat OpenShift, and Docker EE clusters on a Cisco ACI fabric. It allows the cluster pods to be treated as fabric end points in the fabric integrated overlay, as well as providing IP Address Management (IPAM), security, and load balancing services.

Release Notes are sometimes updated with new information about restrictions and bugs. See the following website for the most recent version of this document:

https://www.cisco.com/c/en/us/support/cloud-systems-management/application-policy-infrastructure-controller-apic/tsd-products-support-series-home.html

For more information about this product, see "Related Content."

Note: The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product.

Date

Description

February 28, 2022

Updated scale details for OpFlex hosts per leaf.

July 22, 2021

Added information for OpFlex hosts per port. See Supported Scale section.

March 26, 2021

Added CSCvx52603, CSCvw59865 to the resolved issues table. 

Moved CSCvx41784 from the open issues table to the resolved issues table.

February 22, 2021

Moved CSCvx40525 from the open issues table to the resolved issues table.

February 17, 2021

Release 5.1(3) became available.

New Software Features

Feature

Description

Support for Kubernetes 1.19 and 1.20

Cisco ACI now supports Kubernetes 1.19 and 1.20 using the Cisco ACI Container Network Interface (CNI) plug-in.

Installations performed with kubeadm on Ubuntu are supported.

Support for OpenShift 4.6 in OpenStack Red Hat OpenStack Platform (OSP) 13

Cisco ACI now supports Red Hat OpenShift 4.6 nested in Red Hat (OSP) 13. To enable this support, Cisco ACI provides customized Ansible modules to complement the upstream OpenShift installer.

For more information, see Installing OpenShift 4.6 on OpenStack 13.

Promethus statistics for datapath metrics

Cisco ACI CNI plugin exports interface and datapath metrics collected from the Opflex agent to Prometheus.

For more information, see OpFlex Prometheus Integration.

Drop Logs

Cisco ACI CNI plugin provides ability to log and correlate enforced policy when packets are dropped by the virtual switch on the compute nodes.

For more information, see Enabling the OpFlex Drop Log Feature.

EndpointSlices

Cisco ACI CNI supports the use of EndpointSlices Kubernetes resource if configured.

Cisco ACI CNI will default to processing EndpointSlices instead of Endpoints in any new Kubernetes deployments 1.18 or later.

Named Ports

Cisco ACI CNI supports use of symbolic names for target ports in Kubernetes Network Policies.

For more information, see the Kubernetes documentation on Network Policy.

Cisco ACI Virtualization Compatibility Matrix

For information about Cisco ACI supported Container Products, see the Cisco ACI Virtualization Compatibility Matrix at the following URL:

https://www.cisco.com/c/dam/en/us/td/docs/Website/datacenter/aci/virtualization/matrix/virtmatrix.html

Changes in Behavior

     Cisco ACI CNI plug-in will default to processing EndpointSlices instead of Endpoints in any new Kubernetes deployments 1.18 or later. If the Kubernetes EndpointSlice feature gate is explicitly disabled during installation, the ACI CNI plug-in will revert to processing the Endpoints resource.

     The export of statistics to Prometheus is automatically enabled.

Supported Scale

For the verified scalability limits (except for CLI limits), see the Verified Scalability Guide for this release. For Kubernetes-based Integrations (including Docker, OpenShift, and Rancher), and OpenStack Platform Scale Limits, see the following table.

Note: The scalability information in the following table applies to Kubernetes or OpenStack resources integrated with OpFlex into the Cisco ACI fabric. It does not apply to Microsoft SCVMM hosts or Cisco ACI Virtual Edge instances.

Limit Type

Maximum Supported

Number of OpFlex hosts per leaf

1201

Number of OpFlex hosts per port

20

Number of vPC links per leaf

40

Number of endpoints per leaf

10,000

Number of endpoints per host

400

Number of virtual endpoints per leaf

40,000

 

1-   The indicated scale value is for Cisco ACI version 5.0(1) and later. If the ACI version is less than 5.0(1), the number of supported OpFlex hosts are 40.

Notes:

     For containers, an endpoint corresponds to a pod’s network interface.

     For OpenStack, an endpoint corresponds to any of the following:

    A virtual machine (VM) interface (also known as vnic)

    A DHCP agent’s port in OpenStack (if in DHCP namespace on the network controller)

    A floating IP address

     Total virtual endpoints on a leaf can be calculated as virtual endpoints / leaf = VPCs x EPGs, where:

    VPCs is the number of VPC links on the switch in the attachment profile used by the OpenStack Virtual Machine Manager (VMM).

    EPGs is the number of EPGs provisioned for the OpenStack VMM.

     For the CLI verified scalability limits, see the Cisco NX-OS Style Command-Line Interface Configuration Guide for this release.

     For OpFlex hosts per port a port is either a physical port or a vPC. One vPC equals one port.The number of member ports in a vPC is inconsequential.

Known Limitations

     The NodePort service statistics exported to Prometheus get accounted under ClusterIp service statistics in on-premise deployments.

     A pod selector has to be always provided to map a port name to the port number, and an empty pod selector is not supported in the ingress direction.

     Istio 1.6.5 deployment is a preview feature and is expected to rapidly evolve in the next release in response to upstream community changes. This may create issues with backward compatibility and as such this feature should only be used in experimental or pilot deployments.

     The Cisco ACI CNI Plug-in is not integrated with the Multi-Site Orchestrator. When deploying to a Multi-Site deployment, the Cisco ACI configurations implemented by the plug-in must not be affected by the Multi-Site Orchestrator.

     SNAT is not supported for services inside the same fabric.

     Due to Python 3 dependencies that are currently available only on RHEL8, acc-provision tool is supported on RHEL8 operating system, but not on RHEL7 operating system.

Usage Guidelines

     Note that upgrading a Cisco ACI CNI cluster requires running acc-provision with the "--upgrade" option.

     Metrics data for various features is pulled and exposed from opflex-agent at different timer intervals. In a steady state, statistics will become eventually consistent. However, if traffic is flowing continuously, there could be slight discrepancy when comparing statistics of various exported metrics. For example, the POD and Service counts are pulled at different intervals of time. While checking these at a particular instant of time can show variations, once in a steady state the statistics will be eventually consistent.

     It is recommended that the in-cluster Prometheus server have a low retention time since Prometheus doesn’t support horizontal auto-scaling. In general, there should be a federated Prometheus server with long term storage solution to avoid hogging CPU and memory of a cluster.

     To enable drop logging, perform the following configuration in the acc-provision input file:

drop_log_config:

enable: True

For more information, see Enabling the OpFlex Drop Log Feature.

     Istio installation can be disabled by setting the config parameter “install-istio” to False in the acc-provision-input file and generate/apply the deployment file.

     The scope of the SNAT service graph contract can be configured by the user in the acc-provision input file as follows:

kube_config:

  snat_operator:

    contract_scope: <scope name>

Valid values (as allowed by Cisco APIC) are "global", "tenant" and "context". The default is set to "global".

     The aci-containers-controller pod subscribes for notifications on certain objects to the Cisco APIC. There is a timeout associated with this subscription. A shorter timeout requires more frequent subscription renewals. The timeout is set to 900 seconds for Cisco APIC 4.x and can be changed by configuring the acc-provision input file:

aci_config:

  apic_refreshtime: 1200

Note: The subscription timeout is configurable only in Cisco APIC 4.x or later.

     The memory limit for the Open vSwitch container is set to 1GB. It can be changed by configuring the acc-provision input file as follows:

kube_config:

  ovs_memory_limit: 5Gi

     The Multus CNI deployment can enabled in the OpenShift installation by performing the following configuration in the acc-provision input file:

multus:

  disable: False

     Policy Based Routing (PBR) tracking can be enabled for the Cisco APIC service graph created for supporting the SNAT feature. More details on PBR tracking can be found in the chapter "Configuring Policy-Based Redirect" In the Cisco APIC Layer 4 to Layer 7 Services Deployment Guide, Release 4.2(x).

One HealthGroup for each node is created, and it is associated with the redirect policy of the SNAT service graph with the internet protocol service level agreement (IP SLA) interval set to 5 seconds. This interval is configurable through the acc- provision input file:

net_config:

  service_monitor_interval: 10

If the service_monitor_interval is set to zero, PBR tracking is disabled.

PBR tracking can be also be enabled for other Cisco APIC service graphs created for each Kubernetes external service, setting the following configuration in the acc-provision input file:

net_config:

  pbr_tracking_non_snat: true

If enabled, the service_monitoring_interval described earlier applies here as well.

Note: In a Cisco ACI CNI-based cluster, the same worker node is used to provide both the external Layer 4 load balancer and SNAT services. So if PBR tracking is enabled, and if the worker node reports unhealthy status for SNAT, a fault appears in the redirect policies associated with all other (non-SNAT) service graphs that have this node. However, this fault does not actually affect those other services and traffic from those services is still distributed to that node. The fault manifests for those other services only in the Cisco APIC GUI.

     You should be familiar with installing and using Kubernetes or OpenShift. Cisco ACI does not provide the Kubernetes or OpenShift installer. Refer to the following documents on Cisco.com for details:

    Cisco ACI and Kubernetes Integration

    Installing OpenShift 4.6 on OpenStack 13

    Installing OpenShift 4.5 on VMware vSphere

    Cisco ACI CNI Plugin for Red Hat OpenShift Container Platform Architecture and Design Guide

    Upgrading the Cisco ACI CNI Plug-in

     The Cisco ACI CNI plug-in implements various functions running as containers inside pods. The released images for those containers for a given version are available on the Docker Hub website under user noiro. A copy of those container images and the RPM/DEB packages for support tools (acc-provision and acikubectl) are also published on the Software Download page on Cisco.com.

     OpenShift has a tighter security model by default, and many off-the-shelf Kubernetes applications, such as guestbook, may not run on OpenShift (if, for example, they run as root or open privileged ports like 80).

     Refer to the article "Getting any Docker image running in your own OpenShift cluster" on the Red Hat OpenShift website for details. The Cisco ACI CNI Plug-in is not aware of any configuration on OpenShift cluster or pods when it comes to working behind a proxy. Running OpenShift "oc new-app”, for instance, may require access to Git Hub, and if the proxy settings on the OpenShift cluster are not correctly set, this access may fail. Ensure your proxy settings are correctly set.

     In this release, the maximum supported number of PBR based external services is 250 virtual IP addresses (VIPs). Scalability is expected to increase in upcoming releases.

Note: With OpenShift, master nodes and router nodes are tainted by default, and you might see lower scale than an upstream Kubernetes installation on the same hardware.

     Some deployments require installation of an "allow" entry in IP Tables for IGMP. This must be added to all hosts running an OpFlex agent and using VXLAN encapsulation to the leaf. The rule must be added using the following command:

$ iptables -A INPUT -p igmp -j ACCEPT

In order to make this change persistent across reboots, add the command either to /etc/rc.d/rc.local or to a cron job that runs after reboot.

     Both RHEL and Ubuntu distributions set net.ipv4.igmp_max_memberships set to 20 by default. This limits the number of end point groups (EPGs) that can be used in addition to the kube-default EPG for pod networking. If you anticipate using more than 20 EPGs, set the value to the desired number of EPGs on each node as follows:

$ sysctl net.ipv4.igmp_max_memberships=desired_number_of_epgs

     For the VMware VDS integration, you can refer to the Enhanced Link Aggregation Group (eLAG) configured through the Cisco APIC by using the following configuration in the acc-provision input file:

nested_inside:
 type: vmware

 elag_name: <eLAG-name-used>

Open Issues

There are no open issues in this release.

Resolved Issues

Click the bug ID to access the Bug Search tool and see additional information about the bug.

Bug ID                    

Description

CSCvx40525

DropLog iptables rule not installed for Ubuntu

CSCvw69790

OCP 4.4: dns-default CoreDNS pods are constantly crashing on control nodes.

CSCvv47774

The application EPG or the corresponding bridge domain's public subnet may be advertised out of an L3Out in another VRF instance without a contract with the L3Out under certain conditions.

CSCvx18022

acc-provision gives an error when vDS managed by APIC uses Enchanced LAG.

CSCvx52603

Container host opflex agent doesnt reconnect after leaf tears down session.

CSCvw59865

MAC addresses to be generated based on IP for K8s CNI.

CSCvx41784

OpenShift 4.5: opflex-agent container in aci-containers-host pod crashing in a high scaled setup.

Known Issues

There are no known issues in this release.

Related Content

See the Cisco Application Policy Infrastructure Controller (APIC) page for the documentation.

The documentation includes installation, upgrade, configuration, programming, and troubleshooting guides, technical references, release notes, and knowledge base (KB) articles, as well as other documentation. KB articles provide information about a specific use case or a specific topic.

By using the "Choose a topic" and "Choose a document type" fields of the APIC documentation website, you can narrow down the displayed documentation list to make it easier to find the desired document.

You can watch videos that demonstrate how to perform specific tasks in the Cisco APIC on the Cisco Data Center Networking YouTube channel.

Documentation Feedback

To provide technical feedback on this document, or to report an error or omission, send your comments to apic-docfeedback@cisco.com. We appreciate your feedback.

Legal Information

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: http://www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

© 2021 Cisco Systems, Inc. All rights reserved.

Learn more