Server Specifications
This appendix lists the physical, environmental, and power specifications for the server.
Physical Specifications
The following table lists the physical specifications for the server versions.
Description |
Specification |
Height |
7.0 in. (177.8 mm) 4 rack-unit (4RU) |
Width |
19.0 in. (482.6 mm) |
Depth (length including front handles and power supplies) |
32.7 in. (830.6 mm) |
Maximum weight (fully loaded chassis) |
146 lb. (66.2 Kg) |
Environmental Specifications
The following table lists the environmental requirements and specifications for the server.
Description |
Specification |
Temperature, Operating |
41 to 95°F (5 to 35°C) Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level. For more information, see the Cisco Unified Computing System Site Planning Guide: Data Center Power and Cooling. |
Temperature, non-operating (when the server is stored or transported) |
–40 to 149°F (–40 to 65°C) |
Humidity (RH), operating |
10 to 90% |
Humidity (RH), non-operating (when the server is stored or transported) |
5 to 93% |
Altitude, operating |
0 to 10,000 feet (0 to 3048 m) |
Altitude, non-operating (when the server is stored or transported) |
0 to 39,370 feet (0 to 12,000 m) |
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) |
|
Sound power |
|
Power Specifications
Note |
Do not mix power supply types or wattages in the server. Both power supplies must be identical. |
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
1600 W AC Power Supply
This section lists the specifications for each 1600 W AC power supply (Cisco part number UCSC-PSU1-1600W).
Description |
Specification |
AC Input Voltage |
Nominal range: 200–240 VAC (Range: 180–264 VAC) |
AC Input Frequency |
Nominal range: 50 to 60Hz (Range: 47–63 Hz) |
Maximum AC Input current |
9.5 A at 200 VAC |
Maximum input volt-amperes |
1250 VA at 200 VAC |
Maximum inrush current |
30 A at 35° C |
Maximum hold-up time |
80 ms at 1600 W |
Maximum output power per PSU |
1600 W at 200–240 VAC |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
Climate Savers Platinum Efficiency (80Plus Platinum certified) |
Form factor |
RSP2 |
Input connector |
IEC320 C14 |