Technical Specifications

This appendix provides the technical specification for the Cisco IE 1000 switches.

Operating Temperature Specifications

Table 1 lists the Operating Temperatures (measured inside enclosure, 1” below switch) for the Cisco IE 1000 switches.

 

Table 1 Operation Temperature Specification for the Cisco IE 1000 Switches

 
Industrial Automation and Hazardous Locations
Substation
Traffic Signal

Enclosure types

Sealed enclosures (No airflow)

For example: NEMA4, NEMA4X, NEMA12, NEMA13, IP54, and IP66.

Vented enclosures (Minimum 40 lfm1)

For example: NEMA1, IP20, and IP21.

Fan or blower-equipped enclosures (Minimum 200 lfm)

Temperatures (measured inside enclosure, 1” below switch)

POE: -40C to +60C

Non-POE: -20C to +60C

POE: -40C to +70C

Non-POE: -20C to +70C

POE: -34C to +74C

Non-POE: -16C to +74C

1.lfm = linear feet per minute.

Note: The safety certifications apply only to ambient temperatures under 158°F (70°C) measured 1” below switch. However, the Cisco IE 1000 switch can function under the environmental conditions shown in Table 1.

Technical Specifications

The technical specifications for the Cisco IE 1000 switches are as follows:

Table 2 Cisco IE 1000 Technical Specifications

Environmental Ranges

Storage temperature

–40 to 185°F (–40 to 85°C)

Operating temperature 2

(Measured inside enclosure, 1” below switch)

 
POE

 
Non-POE

 
-34C to +74C

blank.gif -40C to +70C (40 lfm Vented Enclosure Operating)

blank.gif -40C to +60C (Sealed Enclosure Operating)

blank.gif -34C to +74C (Minimum 200 lfm Fan or Blower equipped Enclosure Operating)

-40C to +85C (Type Tested to +85C for 16 hours) 3

 
-16C to +74C

blank.gif -20C to +70C (40 lfm Vented Enclosure Operating)

blank.gif -20C to +60C (Sealed Enclosure Operating)

blank.gif -16C to +74C (Minimum 200 lfm Fan or Blower equipped Enclosure Operating)

85C Type Tested for 16 hours

Operating humidity

5 to 95% (noncondensing)

Operating shock

30 g at 11 ms, and 200 g at 2.11 ms.

Operating altitude

Up to 13,000 ft (3962 m)

Storage altitude

Up to 40,000 ft (12,192 m)

Power Requirements

DC input voltage

blank.gif Marked range:

blank.gif 12-24 VDC (IE1000-4T1T / IE1000-6T2T)

blank.gif 48-54 VDC (IE1000-4P2S / IE1000-8P2S)

blank.gif Maximum operating range:

blank.gif 9-32 VDC (IE1000-4T1T / IE1000-6T2T)

blank.gif 48-54 VDC (IE1000-4P2S / IE1000-8P2S)

Note:

blank.gif The DC-input power supply is an SELV circuit, and it can only be connected to another SELV circuit.

Power consumption

blank.gif IE-1000-4T1T-LM -- 3.6W

blank.gif IE-1000-6T2T-LM -- 4.8W

blank.gif IE-1000-4P2S-LM -- 140.4W

blank.gif IE-1000-8P2S-LM -- 205.2W

Physical Dimensions

Weight

IE-1000-4T1T-LM -- 1.10 lb (0.50 kg)
IE-1000-6T2T-LM -- 1.25 lb (0.57 kg)
IE-1000-4P2S-LM -- 1.70 lb (0.77 kg)
IE-1000-8P2S-LM -- 1.85 lb (0.84 kg)

Dimensions (W x D x H).8 x 5.3 x 5 in. (45.7 x 134 x 127 mm)4

IE-1000-4T1T-LM -- 1.5 x 4.5 x 5 in. (38.1 x 115 x 127 mm)
IE-1000-6T2T-LM -- 1.8 x 4.5 x 5 in. (45.7 x 115 x 127 mm)
IE-1000-4P2S-LM -- 1.8 x 5.3 x 5 in. (45.7 x 134 x 127 mm)
IE-1000-8P2S-LM -- 1

2.Operating temperatures exceeding 60C are not covered by the product safety certifications and approvals. However, the switch can function in the installations under the environmental conditions listed.

3.When using industrial grade SFP modules, maximum operating temperature limits shown in table 1 apply. When using commercial grade SFP modules, maximum system operating temperature limits must be de-rated by 15 deg. C.

4.Width includes the cosmetic end-caps. Height does not include the power and alarm connections.

Alarm Ratings

The alarm ratings for the Cisco IE 1000 switches are below.

 

Table 3 Cisco IE 1000 Alarm Ratings

Alarm Ratings
Specification

Alarm output electrical specification

1.0 A @ 24 VDC or 0.5 A @ 48 VDC