System Specifications

Environmental Specifications

Environment

Specification

Temperature

Ambient operating temperature

32 to 104°F (0 to 40°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Humidity

Ambient operating humidity

8 to 80%

Ambient nonoperating

5 to 95%

Altitude*

Ambient operating altitude

0 to 10,000 feet (0 to 3,048 meters)

For China, 6,562 ft (2000 m)

Ambient nonoperating

-1000 to 30,000 feet (-304 to 15,150 meters)

* The Cisco Nexus switch functions in operating temperatures of up to 40°C at sea level. For every 300 meters (1000 ft) above sea level, the maximum temperature is reduced by 1°C. For more details on environmental requirements, see the Cisco Datasheet.

Switch Dimensions

Switch

Width

Depth

Height

Cisco Nexus 9364E-SG2-Q

17.3 inches (43.94 cm)

24.70 inches (62.74 cm) without fan module and power supply module

26.26 inches (66.70 cm) with fan module and power supply module

3.43 inches (8.71 cm)

Switch and Module Weights and Quantities

Component

Weight per Unit

Quantity

Cisco Nexus 9364E-SG2 Chassis (N9364E-SG2-Q)

34.18 lb (15.50 kg) without Fan module and Power supply module

44.86 lb (20.35kg) with Fan module and Power supply module

1

Fan Module

– Port-side intake (burgundy) (FAN-PI-V4)

1.16 lb (1.53 kg)

4

Power Supply module

– 3000-W AC/HVPI port-side intake (burgundy) (PSU3KW-HVPI)

3.02 lb (1.37 kg)

2 (1 for operations and 1 for redundancy)

Switch Power Input Requirements

This table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions.


Note


Some power supplies have capabilities that are greater than the maximum power requirements for a switch. To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed here.


Switch Typical Power Consumption (AC or DC) Maximum Power Consumption (AC or DC) Heat Dissipation Requirement

Cisco Nexus 9364E-SG2-Q

2029 W

2960 W

10096 BTUs per hour

Power Specifications

Power specifications include the specifications for each type of power supply module.

3000-W AC Power Supply Specifications

These specifications apply to the PSU3KW-HVPI power supplies.

Property Specification

Power

3000 W

Input Voltage

200-277 VAC

Frequency

50 to 60 Hz

Efficiency

90% or greater (20 to 100% load)

Redundancy Modes

Combined, n+1, and n+n

RoHS Compliance

Yes

Hot Swappable

Yes

Airflow Direction

Port-side intake airflow

Power Cable Specifications

These sections show the power cables that you can order and use with this switch.

Power Cable Specifications for AC Power Supplies

Location

Part Number

Length

Power Cord Rating

Argentina

CAB-AC-16A-SG-AR

14 feet (4.26 m)

16A, 250 VAC

Australia

CAB-AC-16A-SG-AZ

14 feet (4.26 m)

16A, 250 VAC

Brazil

CAB-AC-16A-SG-BR

14 feet (4.26 m)

16A, 250 VAC

China

CAB-AC-16A-SG-CH

CAB-AC-16A-CN

14 feet (4.26 m)

16A, 250 VAC

Europe

CAB-AC-16A-SG-EU

14 feet (4.26 m)

16A, 250 VAC

India

CAB-AC-16A-SG-IND

14 feet (4.26 m)

16A, 250 VAC

International / UK

CAB-AC-16A-SG-IN

14 feet (4.26 m)

16A, 250 VAC

Israel

CAB-AC-16A-SG-IS

14 feet (4.26 m)

16A, 250 VAC

Italy

CAB-AC-16A-SG-IT

14 feet (4.26 m)

16A, 250 VAC

Japan

CAB-AC-16A-SG-JP

14 feet (4.26 m)

16A, 250 VAC

South Africa

CAB-AC-16A-SG-SA

14 feet (4.26 m)

16A, 250 VAC

Switzerland

CAB-AC-16A-SG-SW

14 feet (4.26 m)

16A, 250 VAC

South Korea

CAB-AC-16A-SG-SK

14 feet (4.26 m)

16A, 250 VAC

United Kingdom

CAB-AC-16A-SG-UK

14 feet (4.26 m)

16A, 250 VAC

North America (non locking) 200-240 VAC operation

CAB-AC-20A-SG-US2

14 feet (4.26 m)

20A, 250 VAC

North America (locking) 200-240 VAC operation

CAB-AC-20A-SG-US3

14 feet (4.26 m)

20A, 250 VAC

North America 277 VAC operation

CAB-AC-20A-SG-US4

14 feet (4.26 m)

20A, 277 VAC

North America Cabinet Jumper Power Distribution Unit (PDU)

CAB-AC-20A-SG-C20

14 feet (4.26 m)

20A, 250 VAC

HVAC/HVDC Power Cables

Part Number

Cord Set Description

Photo

CAB-HVAC-SD-0.6M

HVAC

2-foot (0.6 m) cable with Saf-D-Grid and SD connectors

277V AC

CAB-HVAC-C14-2M

HVAC

6.6-foot (2.0 m) cable with Saf-D-Grid and C14 (use for up to 240 V) connector

250V AC

CAB-HVAC-RT-0.6M

HVAC

2-foot (0.6 m) cable with Saf-D-Grid and RT connector

277V AC

NO-POWER-CORD

All except Argentina, Brazil, and Japan

No power cord included with switch

Not applicable

Table 1. HVAC/HVDC Power Cables Callout Table

1

Connect this end to the power supply unit.

Regulatory Standards Compliance Specifications

This table lists the regulatory standards compliance for the switch.

Table 2. Regulatory Standards Compliance: Safety and EMC

Specification

Description

Regulatory compliance

Products should comply with CE Markings according to directives 2004/108/EC and 2006/95/EC.

Safety

  • CAN/CSA-C22.2 No. 60950-1 Second Edition

  • CAN/CSA-C22.2 No. 62368-1-19 Third Edition

  • ANSI/UL 60950-1 Second edition

  • IEC 62368-1

  • EN 62368-1

  • AS/NZS 62368-1

  • GB4943

  • UL 62368-1

EMC: Emissions

  • 47CFR Part 15 (CFR 47) Class A

  • AS/NZS CISPR22 Class A

  • CISPR22 Class A

  • EN55022 Class A

  • ICES003 Class A

  • VCCI Class A

  • EN61000-3-2

  • EN61000-3-3

  • KN22 Class A

  • CNS13438 Class A

EMC: Immunity

  • EN55024

  • CISPR24

  • EN300386

  • KN 61000-4 series

RoHS

The product is RoH-6 compliant with exceptions for leaded-ball grid-array (BGA) balls and lead press-fit connectors.