Prerequisites for Configuring LAN/WAN-PHY Controller Interfaces
You must be in a user group associated with a task group that includes the proper task IDs. The command reference guides include the task IDs required for each command. If you suspect user group assignment is preventing you from using a command, contact your AAA administrator for assistance.
Before configuring a LAN/WAN-PHY controller, be sure that the following tasks and conditions are met:
-
You have installed one of the following cards that supports the LAN/WAN-PHY controller:
-
1-Port 10-Gigabit Ethernet LAN/WAN-PHY Shared Port Adapter
-
4-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM (XFP optics)
-
8-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM (XFP optics)
-
14-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM
-
20-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM
-
Restrictions
The LAN/WAN-PHY controller has the following restrictions:
-
LAN-PHY mode is configurable using the lanmode on command only on the 1-Port 10-Gigabit Ethernet LAN/WAN-PHY SPA. The default mode of the LAN/WAN-PHY controller is WAN mode for the 1-Port 10-Gigabit Ethernet SPA.
-
WAN-PHY mode is configurable using the wanmode on command only on the 10-Gigabit Ethernet LAN/WAN-PHY PLIMs. The default mode of the LAN/WAN-PHY controller is LAN mode for the following SPAs:
-
4-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM (XFP optics)
-
8-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM (XFP optics)
-
14-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM
-
20-Port 10-Gigabit Ethernet LAN/WAN-PHY PLIM
-