ALC-IN-PROGRESS-RX
Default Severity: Minor (MN), Service-Affecting (SA)
Logical Object: Controller OTS
The Automatic-link-calibration procedure is running in RX direction (ALC-IN-PROGRESS-RX) alarm is raised when the ALC pre-check conditions are cleared and ALC calibration starts on RX ports of a link.
Clear the ALC-IN-PROGRESS-RX Alarm
SUMMARY STEPS
- Collect logs to gather detailed diagnostic information. Use the show tech-support command in privileged EXEC mode:
- Wait until the ALC calibration is completed on the port.
- Manually terminate the ALC calibration on the port.
DETAILED STEPS
|
Step 1 |
Collect logs to gather detailed diagnostic information. Use the show tech-support command in privileged EXEC mode: Example:
|
|
Step 2 |
Wait until the ALC calibration is completed on the port. |
|
Step 3 |
Manually terminate the ALC calibration on the port. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). Provide the logs collected in step 1 to Cisco TAC. |