Perform Preliminary Checks

After successfully logging into the console, you must perform some preliminary checks to verify the default setup. If any setup issue is detected, take corrective action before making further configurations.


Note


The output of the examples in the procedures is not from the latest software release. The output will change for any explicit references to the current release.



Note


  • Refer to System Health Check for monitoring systems in a network to proactively prevent potential issues and take preventative steps.


Inventory Support in NCS 1014

Table 1. Feature History

Feature Name

Release Information

Description

Inventory Support

Cisco IOS XR Release 7.11.1

Inventory support and pluggable optics support for QSFP28,QSFP-DD and Coherent Interface Module (CIM 8) are enabled in NCS 1014 system.

Inventory support

Cisco IOS XR Release 25.1.1

Inventory support and pluggable optics support are enabled in NCS 1014 system.

  • NCS1K-MD-32O-CE and NCS1K-MD-32E-CE

  • ONS-QSFP-OTDR

  • DP01QSDD-ZT5-A1

  • ONS-SC-PTP-1510

The NCS 1014 inventory model consists of the following components.

  • One NCS 1014 controller card.

  • NCS 1014 chassis.

  • Two AC or DC power supply units (PSU) of 2KW and 2.5KW.

  • Three FAN trays.

  • Four line cards.

The components are connected to a 2RU chassis. NCS 1014 can support upto four line cards at once at any given point in time. The line cards supported are NCS1K14-EDFA2, 1.2T, NCS1K4-2.4T-K9, CCMD-16-C and CCMD-16-L cards.


Note


CCMD-16-C: refers to the NCS1K14-CCMD-16-C card.

CCMD-16-L: refers to the NCS1K14-CCMD-16-L card.

1.2T : refers to the NCS1K4-1.2T-K9 C-band card.

2.4T: refers to the NCS1K4-2.4T-K9 C-band card.

EDFA2: refers to the NCS1K4-EDFA2 C-band card.

NCS1K-MD-32O-CE: refers to the NCS 1000 32chs Odd Mux/Demux-150GHz-C-band Enhanced

NCS1K-MD-32E-CE: refers to the NCS 1000 32chs Even Mux/Demux-150GHz-C-band Enhanced


The show inventory command retrieves and displays the inventory information about each Cisco product in the form of a Unique Device Identifier (UDI). The UDI is a combination of three separate data elements: a product identifier (PID), a version identifier (VID), and the serial number (SN). The PID is the name by which the product is ordered. It is also known as product name or part number.

The VID is the version of the product. Whenever a product is upgraded the VID gets incremented according to the changes added. The SN is the vendor based unique serial number assigned to any product. It is used to identifying any specific product.

Verify Inventory

The show inventory command displays the details of the hardware inventory of NCS 1014.

To verify the inventory information for all the physical entities, use the following command.

show inventory [ all | details | fan | power | vendor-type | raw | chasis | word ] [ location | location ].


Note


The various options available under show inventory command are listed below.

  • Word: Partially qualified location specification

  • All: Inventory information for all the physical entities

  • Chassis: Inventory information about chassis

  • Details: Detailed entity information

  • Fan: Inventory information about fan

  • Location: Location of node for inventory

  • Power: Inventory information about power

  • Raw: Raw information

  • Vendor-type: Vendor type information


Example

RP/0/RP0/CPU0:ios#show inventory ?
  WORD         Partially qualified location specification
  all          Inventory information for all the physical entities
  chassis      Inventory information about chassis
  details      detailed entity information
  fan          Inventory information about fan
  location     Location of node for inventory
  power        Inventory information about power
  raw          raw information
  vendor-type  vendor-type information
  |            Output Modifiers
  <cr>

Procedure


show inventory

When you execute this command in the Cisco IOS XR EXEC mode, it displays the summary of NCS 1014 inventory based on different card and optics pluggables on all the slots or ports.

Example:

P/0/RP0/CPU0:RINode1#show inventory 
Mon Feb 24 14:09:11.902 IST

NAME: "Rack 0", DESCR: "Network Convergence System 1014 chassis with timing support"
PID: NCS1014           , VID: V02 , SN: FCB2814B1L3

NAME: "0/RP0/CPU0", DESCR: "Network Convergence System 1014 Controller"
PID: NCS1K14-CNTLR-K9  , VID: V01, SN: FCB2815B21F

NAME: "0/FT0", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0CB

NAME: "0/FT1", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0J8

NAME: "0/FT2", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0HY

NAME: "0/PM0", DESCR: "Network Convergence System 1004 AC Power Supply Unit 2.5KW"
PID: NCS1K4-AC-PSU-2   , VID: V01, SN: POG27500N7Q

NAME: "0/0/NXR0", DESCR: "NCS 1014 EDFA terminal with equalization"
PID: NCS1K14-EDFA2     , VID: V00, SN: FCB2813B3AU

NAME: "0/1/NXR0", DESCR: "Network Convergence System 1014 Filler"
PID: NCS1K14-BLANK     , VID: V01, SN: N/A

NAME: "0/2/NXR0", DESCR: "Network Convergence System 1014 Filler"
PID: NCS1K14-BLANK     , VID: V01, SN: N/A

NAME: "0/3/NXR0", DESCR: "NCS1K4 12x QSFP28 2 Trunk C-Band DWDM card"
PID: NCS1K4-1.2T-K9    , VID: V00, SN: CAT2250B0CA

NAME: "0/4", DESCR: "NCS 1000 32chs Odd Mux/Demux-150GHz-C-band Enhanced"
PID: NCS1K-MD-32O-CE   , VID: V00 , SN: LNA28100006

NAME: "0/5", DESCR: "NCS 1000 32chs Even Mux/Demux-150GHz-C-band Enhanced"
PID: NCS1K-MD-32E-CE   , VID: V00 , SN: ACW2804YJ08

NAME: "0/RP0-PTP0", DESCR: "Cisco Pluggable Optics Module"
PID: SFP-GE-S          , VID: V01, SN: FNS14320XVV

NAME: "0/RP0-PTP1", DESCR: "Cisco Pluggable Optics Module"
PID: FTRJ8519P1BNL-C6  , VID: N/A, SN: FNS11500MWJ

NAME: "Optics0/0/0/5", DESCR: "Cisco SFP GE 1510 OSC Pluggable Optics Module"
PID: ONS-SC-PTP-1510   , VID: V01, SN: MZH2719009Y

NAME: "Optics0/0/0/6", DESCR: "Cisco QSFP DD Pluggable Optical Time Domain Reflectometer"
PID: ONS-QSFP-OTDR     , VID: VES1, SN: IIF2814000Y

NAME: "Optics0/0/0/7", DESCR: "Cisco QSFP DD ZT5 Pluggable Optics Module"
PID: DP01QSDD-ZT5-A1   , VID: V01 , SN: ACA282100B6

NAME: "Optics0/3/0/2", DESCR: "Cisco 100G QSFP28 LR4 Pluggable Optics Module"
PID: ONS-QSFP28-LR4    , VID: V01 , SN: FNS240606WT     
RP/0/RP0/CPU0:RINode1#show inventory all
Mon Feb 24 14:10:49.752 IST

NAME: "Rack 0", DESCR: "Network Convergence System 1014 chassis with timing support"
PID: NCS1014           , VID: V02 , SN: FCB2814B1L3

NAME: "0/RP0/CPU0", DESCR: "Network Convergence System 1014 Controller"
PID: NCS1K14-CNTLR-K9  , VID: V01, SN: FCB2815B21F

NAME: "0/FT0", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0CB

NAME: "0/FT1", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0J8

NAME: "0/FT2", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0HY

NAME: "0/PM0", DESCR: "Network Convergence System 1004 AC Power Supply Unit 2.5KW"
PID: NCS1K4-AC-PSU-2   , VID: V01, SN: POG27500N7Q

NAME: "0/0/NXR0", DESCR: "NCS 1014 EDFA terminal with equalization"
PID: NCS1K14-EDFA2     , VID: V00, SN: FCB2813B3AU

NAME: "0/1/NXR0", DESCR: "Network Convergence System 1014 Filler"
PID: NCS1K14-BLANK     , VID: V01, SN: N/A

NAME: "0/2/NXR0", DESCR: "Network Convergence System 1014 Filler"
PID: NCS1K14-BLANK     , VID: V01, SN: N/A

NAME: "0/3/NXR0", DESCR: "NCS1K4 12x QSFP28 2 Trunk C-Band DWDM card"
PID: NCS1K4-1.2T-K9    , VID: V00, SN: CAT2250B0CA

NAME: "0/4", DESCR: "NCS 1000 32chs Odd Mux/Demux-150GHz-C-band Enhanced"
PID: NCS1K-MD-32O-CE   , VID: V00 , SN: LNA28100006

NAME: "0/5", DESCR: "NCS 1000 32chs Even Mux/Demux-150GHz-C-band Enhanced"
PID: NCS1K-MD-32E-CE   , VID: V00 , SN: ACW2804YJ08

NAME: "0/RP0-PTP0", DESCR: "Cisco Pluggable Optics Module"
PID: SFP-GE-S          , VID: V01, SN: FNS14320XVV

NAME: "0/RP0-PTP1", DESCR: "Cisco Pluggable Optics Module"
PID: FTRJ8519P1BNL-C6  , VID: N/A, SN: FNS11500MWJ

NAME: "Optics0/0/0/5", DESCR: "Cisco SFP GE 1510 OSC Pluggable Optics Module"
PID: ONS-SC-PTP-1510   , VID: V01, SN: MZH2719009Y

NAME: "Optics0/0/0/6", DESCR: "Cisco QSFP DD Pluggable Optical Time Domain Reflectometer"
PID: ONS-QSFP-OTDR     , VID: VES1, SN: IIF2814000Y

NAME: "Optics0/0/0/7", DESCR: "Cisco QSFP DD ZT5 Pluggable Optics Module"
PID: DP01QSDD-ZT5-A1   , VID: V01 , SN: ACA282100B6

NAME: "Optics0/3/0/2", DESCR: "Cisco 100G QSFP28 LR4 Pluggable Optics Module"
PID: ONS-QSFP28-LR4    , VID: V01 , SN: FNS240606WT     

RP/0/RP0/CPU0:RINode1#show inventory location 0/0/NXR0 
Mon Feb 24 14:11:56.879 IST

NAME: "0/0/NXR0", DESCR: "NCS 1014 EDFA terminal with equalization"
PID: NCS1K14-EDFA2     , VID: V00, SN: FCB2813B3AU

NAME: "Optics0/0/0/5", DESCR: "Cisco SFP GE 1510 OSC Pluggable Optics Module"
PID: ONS-SC-PTP-1510   , VID: V01, SN: MZH2719009Y

NAME: "Optics0/0/0/6", DESCR: "Cisco QSFP DD Pluggable Optical Time Domain Reflectometer"
PID: ONS-QSFP-OTDR     , VID: VES1, SN: IIF2814000Y

NAME: "Optics0/0/0/7", DESCR: "Cisco QSFP DD ZT5 Pluggable Optics Module"
PID: DP01QSDD-ZT5-A1   , VID: V01 , SN: ACA282100B6
RP/0/RP0/CPU0:RINode1#

To display location based inventory details use this command.

RP/0/RP0/CPU0:RINode1#show inventory location 0/0/NXR0 
Mon Feb 24 14:11:56.879 IST

NAME: "0/0/NXR0", DESCR: "NCS 1014 EDFA terminal with equalization"
PID: NCS1K14-EDFA2     , VID: V00, SN: FCB2813B3AU

NAME: "Optics0/0/0/5", DESCR: "Cisco SFP GE 1510 OSC Pluggable Optics Module"
PID: ONS-SC-PTP-1510   , VID: V01, SN: MZH2719009Y

NAME: "Optics0/0/0/6", DESCR: "Cisco QSFP DD Pluggable Optical Time Domain Reflectometer"
PID: ONS-QSFP-OTDR     , VID: VES1, SN: IIF2814000Y

NAME: "Optics0/0/0/7", DESCR: "Cisco QSFP DD ZT5 Pluggable Optics Module"
PID: DP01QSDD-ZT5-A1   , VID: V01 , SN: ACA282100B6
RP/0/RP0/CPU0:RINode1#

To display chassis based inventory details use this command.

RP/0/RP0/CPU0:RINode1#show inventory chassis 
Mon Feb 24 14:12:32.431 IST

NAME: "Rack 0", DESCR: "Network Convergence System 1014 chassis with timing support"
PID: NCS1014           , VID: V02 , SN: FCB2814B1L3
RP/0/RP0/CPU0:RINode1#

To display fan based inventory details use this command.

RP/0/RP0/CPU0:RINode1#show inventory fan
Mon Feb 24 14:13:05.899 IST

NAME: "0/FT0", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0CB

NAME: "0/FT1", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0J8

NAME: "0/FT2", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0HY

Verify Status of Hardware Components

To verify the status of all the hardware components installed on NCS 1014, perform the following procedure.

Before you begin

Ensure that all the required hardware components are installed on NCS 1014. For installation details, see Cisco Network Convergence System 1014 Hardware Installation Guide.

Procedure


Step 1

show platform

When you execute this command from the Cisco IOS XR EXEC mode, the status of Cisco IOS XR is displayed.

Example:

RP/0/RP0/CPU0:RINode1#show platform
Mon Feb 24 14:13:59.742 IST
Node              Type                     State                    Config state
--------------------------------------------------------------------------------
0/RP0/CPU0        NCS1K14-CNTLR-K9(Active) IOS XR RUN               NSHUT,NMON
0/PM0             NCS1K4-AC-PSU-2          OPERATIONAL              NSHUT,NMON
0/FT0             NCS1K14-FAN              OPERATIONAL              NSHUT,NMON
0/FT1             NCS1K14-FAN              OPERATIONAL              NSHUT,NMON
0/FT2             NCS1K14-FAN              OPERATIONAL              NSHUT,NMON
0/0/NXR0          NCS1K14-EDFA2            OPERATIONAL              NSHUT,NMON
0/1/NXR0          NCS1K14-BLANK            PRESENT                  NSHUT,NMON
0/2/NXR0          NCS1K14-BLANK            PRESENT                  NSHUT,NMON
0/3/NXR0          NCS1K4-1.2T-K9           OPERATIONAL              NSHUT,NMON
0/4               NCS1K-MD-32O-CE          OPERATIONAL              NSHUT,NMON
0/5               NCS1K-MD-32E-CE          OPERATIONAL              NSHUT,NMON

Step 2

show inventory

Displays details of the physical entities of NCS 1014 along with the details of QSFPs when you execute this command in Cisco IOS XR EXEC mode.

Example:

RP/0/RP0/CPU0:RINode1#show platform
Mon Feb 24 14:13:59.742 IST
Node              Type                     State                    Config state
--------------------------------------------------------------------------------
0/RP0/CPU0        NCS1K14-CNTLR-K9(Active) IOS XR RUN               NSHUT,NMON
0/PM0             NCS1K4-AC-PSU-2          OPERATIONAL              NSHUT,NMON
0/FT0             NCS1K14-FAN              OPERATIONAL              NSHUT,NMON
0/FT1             NCS1K14-FAN              OPERATIONAL              NSHUT,NMON
0/FT2             NCS1K14-FAN              OPERATIONAL              NSHUT,NMON
0/0/NXR0          NCS1K14-EDFA2            OPERATIONAL              NSHUT,NMON
0/1/NXR0          NCS1K14-BLANK            PRESENT                  NSHUT,NMON
0/2/NXR0          NCS1K14-BLANK            PRESENT                  NSHUT,NMON
0/3/NXR0          NCS1K4-1.2T-K9           OPERATIONAL              NSHUT,NMON
0/4               NCS1K-MD-32O-CE          OPERATIONAL              NSHUT,NMON
0/5               NCS1K-MD-32E-CE          OPERATIONAL              NSHUT,NMON
RP/0/RP0/CPU0:RINode1#show inventory 
Mon Feb 24 14:14:36.897 IST

NAME: "Rack 0", DESCR: "Network Convergence System 1014 chassis with timing support"
PID: NCS1014           , VID: V02 , SN: FCB2814B1L3

NAME: "0/RP0/CPU0", DESCR: "Network Convergence System 1014 Controller"
PID: NCS1K14-CNTLR-K9  , VID: V01, SN: FCB2815B21F

NAME: "0/FT0", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0CB

NAME: "0/FT1", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0J8

NAME: "0/FT2", DESCR: "Network Convergence System 1014 FAN Module"
PID: NCS1K14-FAN       , VID: V01, SN: FCB2819B0HY

NAME: "0/PM0", DESCR: "Network Convergence System 1004 AC Power Supply Unit 2.5KW"
PID: NCS1K4-AC-PSU-2   , VID: V01, SN: POG27500N7Q

NAME: "0/0/NXR0", DESCR: "NCS 1014 EDFA terminal with equalization"
PID: NCS1K14-EDFA2     , VID: V00, SN: FCB2813B3AU

NAME: "0/1/NXR0", DESCR: "Network Convergence System 1014 Filler"
PID: NCS1K14-BLANK     , VID: V01, SN: N/A

NAME: "0/2/NXR0", DESCR: "Network Convergence System 1014 Filler"
PID: NCS1K14-BLANK     , VID: V01, SN: N/A

NAME: "0/3/NXR0", DESCR: "NCS1K4 12x QSFP28 2 Trunk C-Band DWDM card"
PID: NCS1K4-1.2T-K9    , VID: V00, SN: CAT2250B0CA

NAME: "0/4", DESCR: "NCS 1000 32chs Odd Mux/Demux-150GHz-C-band Enhanced"
PID: NCS1K-MD-32O-CE   , VID: V00 , SN: LNA28100006

NAME: "0/5", DESCR: "NCS 1000 32chs Even Mux/Demux-150GHz-C-band Enhanced"
PID: NCS1K-MD-32E-CE   , VID: V00 , SN: ACW2804YJ08

NAME: "0/RP0-PTP0", DESCR: "Cisco Pluggable Optics Module"
PID: SFP-GE-S          , VID: V01, SN: FNS14320XVV

NAME: "0/RP0-PTP1", DESCR: "Cisco Pluggable Optics Module"
PID: FTRJ8519P1BNL-C6  , VID: N/A, SN: FNS11500MWJ

NAME: "Optics0/0/0/5", DESCR: "Cisco SFP GE 1510 OSC Pluggable Optics Module"
PID: ONS-SC-PTP-1510   , VID: V01, SN: MZH2719009Y

NAME: "Optics0/0/0/6", DESCR: "Cisco QSFP DD Pluggable Optical Time Domain Reflectometer"
PID: ONS-QSFP-OTDR     , VID: VES1, SN: IIF2814000Y

NAME: "Optics0/0/0/7", DESCR: "Cisco QSFP DD ZT5 Pluggable Optics Module"
PID: DP01QSDD-ZT5-A1   , VID: V01 , SN: ACA282100B6

NAME: "Optics0/3/0/2", DESCR: "Cisco 100G QSFP28 LR4 Pluggable Optics Module"
PID: ONS-QSFP28-LR4    , VID: V01 , SN: FNS240606WT     

Verify Software Version

NCS 1014 is shipped with the Cisco IOS XR Software preinstalled. Verify that the latest version of the software is installed.

Procedure


show version

Displays the software version and details such as system uptime.

Example:

RP/0/RP0/CPU0:sanity_176#sh version
Cisco IOS XR Software, Version 25.1.1.34I LNT
Copyright (c) 2013-2024 by Cisco Systems, Inc.
Build Information:
Built By : cisco
Built On : Sun Jan 26 23:09:31 UTC 2025
Build Host : iox-ucs-037
Workspace : /auto/iox-ucs-037-san2/prod/25.1.1.34I.SIT_IMAGE/ncs1010/ws/
Version : 25.1.1.34I
Label : 25.1.1.34I
cisco NCS1010 (C3758R @ 2.40GHz)
cisco NCS1014 (C3758R @ 2.40GHz) processor with 32GB of memory
sanity_176 uptime is 3 days, 23 hours, 59 minutes
NCS 1014 - Chassis

Verify Environmental Parameters

The show environment command displays the environmental parameters of NCS 1014.

To verify the environmental parameters use the following commands show environment [ all | altitude | fan | power | voltage | current | temperature ] [ location | location ].

The following example shows sample output of the show environment command with the fan keyword.
RP/0/RP0/CPU0:RINode1#show environment fan 
Mon Feb 24 14:15:40.158 IST
=============================================================
                                              Fan speed (rpm)
Location      FRU Type                        FAN_0    FAN_1   
-------------------------------------------------------------

0/PM0        NCS1K4-AC-PSU-2                    5696    5696   
0/FT0        NCS1K14-FAN                        7560    6780   
0/FT1        NCS1K14-FAN                        7560    6720   
0/FT2        NCS1K14-FAN                        7560    6780   

The following example shows sample output of the show environment command with the power keyword.

RP/0/RP0/CPU0:ios#show environment power 
Mon Feb 24 14:16:12.970 IST
================================================================================
CHASSIS LEVEL POWER INFO: 0
================================================================================
   Total output power capacity (Group 0 + Group 1) :    2500W +        0W
   Total output power required                     :    1136W
   Total power input                               :     368W
   Total power output                              :     304W

Power Group 0:
================================================================================
   Power       Supply         ------Input----   ------Output---     Status
   Module      Type            Volts     Amps    Volts     Amps    
================================================================================
   0/PM0       NCS1K4-AC-PSU-2 230.5     1.6     12.1      25.2     OK

Total of Group 0:              368W/1.6A         304W/25.2A

================================================================================
   Location     Card Type               Power       Power        Status
                                        Allocated   Used
                                        Watts       Watts
================================================================================
   0/RP0/CPU0   NCS1K14-CNTLR-K9        73          24           ON
   0/FT0        NCS1K14-FAN             170         26           ON
   0/FT1        NCS1K14-FAN             170         27           ON
   0/FT2        NCS1K14-FAN             170         27           ON
   0/0/NXR0     NCS1K14-EDFA2           220         56           ON
   0/3/NXR0     NCS1K4-1.2T-K9          260         112          ON
   0/Rack       NCS1014                 73          15           ON

The following example shows sample output of the show environment command with the temperature keyword.

RP/0/RP0/CPU0:ios#show environment temperature location 0/rp0/CPU0
Mon Feb 24 14:17:00.234 IST
=============================================================================================================
Location  TEMPERATURE                          Value     Crit    Major    Minor    Minor    Major    Crit
          Sensor                             (deg C)     (Lo)     (Lo)     (Lo)     (Hi)     (Hi)    (Hi)
-------------------------------------------------------------------------------------------------------------
0/RP0/CPU0 
          RP_TEMP_PCB                            32      -10       -5        0       80       85       90
          RP_TEMP_HOT_SPOT                       32      -10       -5        0       80       85       90
          RP_TEMP_LTM4638_0                      32      -10       -5        0       85       90       95
          RP_TEMP_LTM4644_0                      30      -10       -5        0       85       90       95
          RP_TEMP_LTM4644_1                      33      -10       -5        0       85       90       95
          RP_TEMP_LTM4638_1                      30      -10       -5        0       80       90       95
          RP_TEMP_LTM4644_2                      32      -10       -5        0       85       90       95
          RP_TEMP_LTM4638_2                      32      -10       -5        0       80       90       95
          TEMP_CPU_DIE                           34      -10       -5        0       80       85       90
          TEMP_DDR_DIMM                          33      -10       -5        0       80       85       90
          TEMP_CPU_SSD                           47      -10       -5        0       70       75       80
          TEMP_CHASSIS_SSD                       31      -10       -5        0       70       75       80
RP/0/RP0/CPU0:ios#

Note


From R25.4.1, the show environment[ all| temperature| location<lc location>] command displays the TEMP_MODULE sensor to indicate the temperature of the pluggable modules. !TEMP_MODULE indicates that the temperature has crossed its threshold limit and an alarm is raised for this sensor.

RP/0/RP0/CPU0:ios#show environment temperature location 0/2
Wed Dec 17 10:09:48.417 UTC
=============================================================================================================
Location  TEMPERATURE                          Value     Crit    Major    Minor    Minor    Major    Crit
          Sensor                             (deg C)     (Lo)     (Lo)     (Lo)     (Hi)     (Hi)    (Hi)
-------------------------------------------------------------------------------------------------------------
0/2/NXR0   
          TEMP_DX_PCB_0                          28      -10       -5        0       80       85       95
.
.
.
output snipped
.
.
.
          TEMP_DX_PCB_3                          24      -10       -5        0       80       85       95
          TEMP_DX_META2_DIE                      26      -10       -5        0       95      100      105
Optics0/2/0/0 
          TEMP_MODULE                            26      -10        0        5       95      100      105
Optics0/2/0/7 
          TEMP_MODULE                            24      -10        0        5       95      100      105
Optics0/2/0/1 
          TEMP_MODULE                            25       -5        0        5       65       70       75
Optics0/2/0/2 
          TEMP_MODULE                            23       -5        0        5       65       70       75
Optics0/2/0/3 
          TEMP_MODULE                            21       -5        0        5       65       70       75
Optics0/2/0/4 
          TEMP_MODULE                            23       -5        0        5       65       70       75

The following example shows sample output of the show environment command with the voltage keyword.

RP/0/RP0/CPU0:RINode1#show environment voltage location 0/rp0/cpu0
Mon Feb 24 14:18:47.918 IST
=============================================================================================================
Location  VOLTAGE                             Value      Crit    Minor    Minor     Crit
          Sensor                              (mV)       (Lo)    (Lo)     (Hi)      (Hi)
-------------------------------------------------------------------------------------------------------------
0/RP0/CPU0 
          RP_ADM1266_12V0                     12020    10800    11280    12720    13200
          RP_ADM1266_3V3_STAND_BY              3306     3070     3200     3400     3530
          RP_ADM1266_5V0                       5045     4650     4850     5150     5350
          RP_ADM1266_3V3                       3319     3070     3200     3400     3530
          RP_ADM1266_2V5_PLL                   2520     2330     2430     2580     2680
          RP_ADM1266_2V5_FPGA                  2504     2330     2430     2580     2680
          RP_ADM1266_1V2_FPGA                  1199     1120     1160     1240     1280
          RP_ADM1266_3V3_CPU                   3326     3070     3200     3400     3530
          RP_ADM1266_2V5_CPU                   2500     2330     2430     2580     2680
          RP_ADM1266_1V8_CPU                   1799     1670     1750     1850     1930
          RP_ADM1266_1V24_VCCREF               1237     1150     1200     1280     1330
          RP_ADM1266_1V05_CPU                  1052      980     1020     1080     1120
          RP_ADM1266_1V2_DDR_VDDQ              1203     1120     1160     1240     1280
          RP_ADM1266_1V0_VCC_RAM               1124      650      700     1250     1300
          RP_ADM1266_1V0_VNN                    868      550      600     1250     1300
          RP_ADM1266_1V0_VCCP                  1177      450      500     1250     1300
          RP_ADM1266_0V6_DDR_VTT                602      560      580      620      640
          RP_ADM1266_12V0_DB                  11998    10800    11280    12720    13200
          RP_ADM1266_3V3_STAND_BY_DB           3304     3069     3201     3399     3531
          RP_ADM1266_5V0_DB                    5000     4650     4850     5150     5350
          RP_ADM1266_3V3_DB                    3328     3069     3201     3399     3531
          RP_ADM1266_2V5_DB                    2504     2325     2425     2575     2675
          RP_ADM1266_1V8_DB                    1812     1674     1746     1854     1926
          RP_ADM1266_1V0_PHY                    998      930      970     1030     1070

The following example shows sample output of the show environment command with the current keyword.

RP/0/RP0/CPU0:RINode1#show environment current 
Mon Feb 24 14:19:22.627 IST
=============================================================================================================
Location  CURRENT                              Value    
          Sensor                               (mA)    
-------------------------------------------------------------------------------------------------------------
0/RP0/CPU0 
          RP_JMAC_1V0_VCCP_IMON                  62
          RP_JMAC_1V0_VNN_IMON                   93
          RP_JMAC_1V0_VCC_RAM_IMON                0
          RP_JMAC_1V2_DDR_VDDQ_IMON              93
          RP_CURRMON_LTM4638_0                  361
          RP_CURRMON_LTM4644_0                  145
          RP_CURRMON_LTM4644_1                  254
          RP_CURRMON_LTM4638_1                  402
          RP_CURRMON_DB                         448
0/0/NXR0   
          IMON_OPTM                            2735
          IMON_CTLPL                            725
          SA_ADM1275_12V_IMON_LC               4632
0/3/NXR0   
          IMON_CLI                                0
          IMON_CTLPL                              0
          IMON_MODULE                             0
          IMON_CDR                                0
          SA_ADM1275_12V_IMON_LC               9358
0/Rack     
          SA_ADM1275_12V_IMON_CPU              2016
          SA_ADM1275_12V_OUTLET_IMON_FAN0      1123
          SA_ADM1275_12V_OUTLET_IMON_FAN1      1105
          SA_ADM1275_12V_OUTLET_IMON_FAN2      1088
          SA_ADM1275_12V_INLET_IMON_FAN0       1123
          SA_ADM1275_12V_INLET_IMON_FAN1       1236
          SA_ADM1275_12V_INLET_IMON_FAN2       1305
          SA_LTC2945_12V_IO_RAILS_IMON          760
          SA_LTC2945_1V_ALDRIN_CORE_IMON       3264
          SA_LTC2945_1V_ALDRIN_SERDES_IMON     1530
          SA_LTC2945_1V_PENNY_CORE_IMON         816
          SA_LTC2945_1V2_PENNY_SERDES_IMON      340
RP/0/RP0/CPU0:RINode1#

This example shows sample output of the show environment command with the all keyword.

RP/0/RP0/CPU0:sanity_176#sh environment all
=============================================================================================================
Location  TEMPERATURE                          Value     Crit    Major    Minor    Minor    Major    Crit
          Sensor                             (deg C)     (Lo)     (Lo)     (Lo)     (Hi)     (Hi)    (Hi)
-------------------------------------------------------------------------------------------------------------
0/RP0/CPU0
          RP_TEMP_PCB                            31      -10       -5        0       80       85       90
          RP_TEMP_HOT_SPOT                       32      -10       -5        0       80       85       90
          RP_TEMP_LTM4638_0                      32      -10       -5        0       85       90       95
          RP_TEMP_LTM4644_0                      30      -10       -5        0       85       90       95
          RP_TEMP_LTM4644_1                      32      -10       -5        0       85       90       95
          RP_TEMP_LTM4638_1                      31      -10       -5        0       80       90       95
          RP_TEMP_LTM4644_2                      30      -10       -5        0       85       90       95
          RP_TEMP_LTM4638_2                      31      -10       -5        0       80       90       95
          TEMP_CPU_DIE                           36      -10       -5        0       80       85       90
          TEMP_DDR_DIMM                          33      -10       -5        0       80       85       90
          TEMP_CPU_SSD                           44      -10       -5        0       70       75       80
          TEMP_CHASSIS_SSD                       31      -10       -5        0       70       75       80
0/PM0
          Air Inlet Temperature                  30      -10       -5        0       62       67       72
          Air Outlet Temperature                 32      -10       -5        0       82       87       92
          Oring MOSFET                           35      -10       -5        0       77       82       87
0/PM1
          Air Inlet Temperature                  31      -10       -5        0       62       67       72
          Air Outlet Temperature                 32      -10       -5        0       82       87       92
          Oring MOSFET                           34      -10       -5        0       77       82       87
0/1/NXR0
          TEMP_DX_PCB                             -      -10       -5        0       95      100      105
          TEMP_DX_ZYNQ                            -      -10       -5        0       95      100      105
          SA_TEMP_OUTLET_LC                       -      -10       -5        0       75       85       90
0/3/NXR0
          TEMP_DX_PCB                            24      -10       -8       -5       85       90       95
          TEMP_DX_ZYNQ                           27      -10       -8       -5       95       98      100
          SA_TEMP_OUTLET_LC                      25      -10       -5        0       75       85       90
0/Rack
          SA_TEMP_CHASSIS_INLET0                 21      -10       -5        0       45       55       60
          SA_TEMP_CHASSIS_INLET1                 21      -10       -5        0       45       55       60
          SA_TEMP_LTM4647_HOTSPOT                32      -10       -5        0       95      105      110
          SA_TEMP_ALDRIN_HOTSPOT                 26      -10       -5        0       80       85       90
          SA_TEMP_INLET_PSU0                     30      -10       -5        0       80       85       90
          SA_TEMP_INLET_PSU1                     30      -10       -5        0       80       85       90
          SA_TEMP_INLET_FAN0                     25      -10       -5        0       80       85       90
          SA_TEMP_INLET_FAN1                     20      -10       -5        0       80       85       90
=============================================================================================================
Location  VOLTAGE                             Value      Crit    Minor    Minor     Crit
          Sensor                              (mV)       (Lo)    (Lo)     (Hi)      (Hi)
-------------------------------------------------------------------------------------------------------------
0/RP0/CPU0
          RP_ADM1266_12V0                     12050    10800    11280    12720    13200
          RP_ADM1266_3V3_STAND_BY              3304     3070     3200     3400     3530
          RP_ADM1266_5V0                       5056     4650     4850     5150     5350
          RP_ADM1266_3V3                       3334     3070     3200     3400     3530
          RP_ADM1266_2V5_PLL                   2515     2330     2430     2580     2680
          RP_ADM1266_2V5_FPGA                  2511     2330     2430     2580     2680
          RP_ADM1266_1V2_FPGA                  1202     1120     1160     1240     1280
          RP_ADM1266_3V3_CPU                   3332     307

Verify Management Interface Status

To verify the management interface status, perform the following procedure.

Procedure


show interfaces mgmtEth instance

Displays the management interface configuration.

Example:

RP/0/RP0/CPU0:RINode1#show interfaces MgmtEth 0/RP0/CPU0/0
Mon Feb 24 14:25:17.125 IST
MgmtEth0/RP0/CPU0/0 is up, line protocol is up 
  Interface state transitions: 1
  Hardware is Management Ethernet, address is 9c38.1888.a418 (bia 9c38.1888.a418)
  Description: mgmt0
  Internet address is 10.127.126.174/27
  MTU 1514 bytes, BW 1000000 Kbit (Max: 1000000 Kbit)
     reliability 255/255, txload 0/255, rxload 0/255
  Encapsulation ARPA,
  Full-duplex, 1000Mb/s, 1000BASE-T, link type is autonegotiation
  loopback not set,
  Last link flapped 2d23h
  ARP type ARPA, ARP timeout 04:00:00
  Last input 00:00:00, output 00:04:50
  Last clearing of "show interface" counters never
  5 minute input rate 0 bits/sec, 1 packets/sec
  5 minute output rate 0 bits/sec, 0 packets/sec
     202558 packets input, 14206120 bytes, 0 total input drops
     0 drops for unrecognized upper-level protocol
     Received 64032 broadcast packets, 137089 multicast packets
              0 runts, 0 giants, 0 throttles, 0 parity
     0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
     330 packets output, 14428 bytes, 0 total output drops
     Output 0 broadcast packets, 4 multicast packets
     0 output errors, 0 underruns, 0 applique, 0 resets
     0 output buffer failures, 0 output buffers swapped out
     1 carrier transitions

In the previous output, the management interface is administratively down.

You can also use the show interfaces summary and show interfaces brief commands in the Cisco IOS XR EXEC mode to verify the management interface status.

The following example shows sample output from the show interfaces summary command.

RP/0/RP0/CPU0:RINode1#show interfaces summary
Mon Feb 24 14:26:00.615 IST
Interface Type          Total    UP       Down     Admin Down
--------------          -----    --       ----     ----------
ALL TYPES               6        5        0        1       
--------------         
IFT_GETHERNET           1        1        0        0       
IFT_LOOPBACK            1        1        0        0       
IFT_ETHERNET            2        2        0        0       
IFT_NULL                1        1        0        0       
IFT_PTP_ETHERNET        1        0        0        1       

The following example shows sample output from the show interfaces brief command.

RP/0/RP0/CPU0:RINode1#show interfaces brief
Mon Feb 24 14:26:32.302 IST

               Intf       Intf        LineP              Encap  MTU        BW
               Name       State       State               Type (byte)    (Kbps)
--------------------------------------------------------------------------------
                Lo0          up          up           Loopback  1500          0
                Nu0          up          up               Null  1500          0
          Gi0/0/0/5          up          up               ARPA  1514    1000000
     Mg0/RP0/CPU0/0          up          up               ARPA  1514    1000000
     Mg0/RP0/CPU0/1          up          up               ARPA  1514    1000000
     PT0/RP0/CPU0/1  admin-down  admin-down               ARPA  1514    1000000

What to do next

If the management interface is administratively down, perform the following steps:

  • Check the Ethernet cable connection.

  • Verify the IP configuration of the management interface. For details on configuring the management interface, see Configure Management Interface.

  • Verify whether the management interface is in the no shut state using the show running-config interface mgmtEth command.

    The following example shows sample output from the show running-config interface mgmtEth command.

    RP/0/RP0/CPU0:ios#show running-config interface mgmtEth 0/RP0/CPU0/0
    interface MgmtEth0/RP0/CPU0/0
     ipv4 address 10.105.57.37 255.255.255.128
    !

Verify Firmware Version

The firmware on various hardware components of NCS 1014 must be compatible with the installed Cisco IOS XR image. Incompatibility may cause the NCS 1014 to malfunction.

To verify the firmware version, perform the following procedure.

Before you begin

Procedure


Step 1

show hw-module fpd

Example:

 RP/0/RP0/CPU0:MOLS_SIT1#show hw-module fpd
Tue Mar 25 16:30:45.888 IST

Auto-upgrade:Enabled,PM included
Attribute codes: B golden, P protect, S secure, A Anti Theft aware
                                                                         FPD Versions
                                                                        ==============
Location   Card type             HWver FPD device       ATR Status    Running  Programd   Reload Loc
-------------------------------------------------------------------------------------------------
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   ADM-DB               CURRENT      2.10     2.10        NOT REQ
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   ADM-MB               CURRENT      2.30     2.30        NOT REQ
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   BIOS             S   CURRENT      5.00     5.00          0/RP0
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   BIOS-Golden      BS  CURRENT               4.70          0/RP0
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   CpuFpga          S   CURRENT      1.17     1.17          0/RP0
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   CpuFpgaGolden    BS  CURRENT               1.09          0/RP0
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   SsdIntelSCKKBGZ  S   CURRENT      1.30     1.30          0/RP0
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   TamFw            S   CURRENT      9.04     9.04          0/RP0
0/RP0/CPU0 NCS1K14-CNTLR-K9      1.0   TamFwGolden      BS  CURRENT               9.04          0/RP0
0/PM0      NCS1K4-AC-PSU-2       1.1   PO-PriMCU            CURRENT      1.03     1.03        NOT REQ
0/PM0      NCS1K4-AC-PSU-2       1.1   PO-SecMCU            CURRENT      1.05     1.05        NOT REQ
0/PM1      NCS1K4-AC-PSU-2       0.1   PO-PriMCU            CURRENT      1.03     1.03        NOT REQ
0/PM1      NCS1K4-AC-PSU-2       0.1   PO-SecMCU            CURRENT      1.05     1.05        NOT REQ
0/0/NXR0   NCS1K14-EDFA2         0.1   CpuModFw         S   CURRENT    251.100  251.100       NOT REQ
0/0/NXR0   NCS1K14-EDFA2         0.1   OptModFw         S   CURRENT      2.04     2.04        NOT REQ
0/1/NXR0   NCS1K14-2.4T-K9       0.1   CpuModFw         S   CURRENT    251.100  251.100        NOT REQ
0/2/NXR0   NCS1K14-2.4T-X-K9     1.0   CpuModFw         S   CURRENT    251.100  251.100       NOT REQ
0/3/NXR0   NCS1K4-QXP-K9         0.2   CpuModFw         S   CURRENT    251.100  251.100       NOT REQ
0/Rack     NCS1014               1.1   ADM-CHASSIS          CURRENT      0.21     0.21        NOT REQ
0/Rack     NCS1014               1.1   IoFpga           S   CURRENT      1.19     1.19        NOT REQ
0/Rack     NCS1014               1.1   IoFpgaGolden     BS  CURRENT               1.05        NOT REQ
0/Rack     NCS1014               1.1   SsdIntelSC2KB    S   CURRENT      1.30     1.30         0/Rack
0/4        NCS1K-MD-32E-CE       0.2   MD-32-LUM        S   CURRENT      2.20     2.20        NOT REQ
0/5        NCS1K-MD-32O-CE       12.1  MD-32-ACC        S   CURRENT      1.12     1.12        NOT REQ
  • Status—Upgrade status of the firmware. The different states are:

    • CURRENT—The firmware version is the latest version.

    • NOT READY—The firmware of the FPD is not ready for upgrade.

    • NEED UPGD—A newer firmware version is available in the installed image. We recommended that upgrade be performed.

    • UPGD PREP—The firmware of the FPD is preparing for upgrade.

    • RLOAD REQ—The upgrade is completed, and the card requires a reload.

    • UPGD DONE—The firmware upgrade is successful.

    • UPGD FAIL—The firmware upgrade has failed.

    • UPGD SKIP—The upgrade is skipped because the installed firmware version is higher than the version available in the image.

    • Running—Current version of the firmware running on the FPD.

Step 2

show fpd package

Use the show fpd package command to display the FPD image version available with this software release for each hardware component.

Example:

RP/0/RP0/CPU0:MOLS_SIT1#show fpd package 
Thu Mar 27 17:55:13.582 IST

=============================== ================================================
                                        Field Programmable Device Package
                                ================================================
                                               Req     SW      Min Req   Min Req
Card Type            FPD Description           Reload  Ver     SW Ver  Board Ver
=================== ========================== ====== ======= ======== =========
--------------------------------------------------------------------------------
NCS1014              ADM-CHASSIS                NO      0.21      0.21      0.0  
                     IoFpga                     NO      1.19      1.19      0.0  
                     IoFpgaGolden               NO      1.05      0.01      0.0  
                     SsdIntelSC2KB              YES     1.30      1.30      0.0  
                     SsdMicron5400              YES     0.02      0.02      0.0  
                     SsdSolidigmSC2KB           YES     1.30      1.30      0.0  
--------------------------------------------------------------------------------
NCS1K-MD-32E-C       MD-32-ACC                  NO      2.18      2.18      0.0  
                     MD-32-NEO                  NO      2.02      2.02      0.0  
--------------------------------------------------------------------------------
NCS1K-MD-32E-CE      MD-32-ACC                  NO      1.10      1.10      0.0  
                     MD-32-LUM                  NO      2.20      2.20      0.0  
--------------------------------------------------------------------------------
NCS1K-MD-32O-C       MD-32-ACC                  NO      2.18      2.18      0.0  
                     MD-32-NEO                  NO      2.02      2.02      0.0  
--------------------------------------------------------------------------------
NCS1K-MD-32O-CE      MD-32-ACC                  NO      1.10      1.10      0.0  
                     MD-32-LUM                  NO      2.20      2.20      0.0  
--------------------------------------------------------------------------------
NCS1K14-2.4T-K9      CIMFw                      NO     80.13021  80.13021   0.0  
                     CpuModFw                   NO    251.100   251.100     0.0  
--------------------------------------------------------------------------------
NCS1K14-2.4T-L-K9    CIMFw                      NO     80.13021  80.13021   0.0  
                     CpuModFw                   NO    251.100   251.100     0.0  
--------------------------------------------------------------------------------
NCS1K14-2.4T-X-K9    CIMFw                      NO     80.13021  80.13021   0.0  
                     CpuModFw                   NO    251.100   251.100     0.0  
--------------------------------------------------------------------------------
NCS1K14-2.4TXL-K9    CIMFw                      NO     80.13021  80.13021   0.0  
                     CpuModFw                   NO    251.100   251.100     0.0  
--------------------------------------------------------------------------------
NCS1K14-CCMD-16-C    CpuModFw                   NO    251.100   251.100     0.0  
                     OptModFw                   NO     20.02     20.02      0.0  
--------------------------------------------------------------------------------
NCS1K14-CCMD-16-L    CpuModFw                   NO    251.100   251.100     0.0  
                     OptModFw                   NO     20.02     20.02      0.0  
--------------------------------------------------------------------------------
NCS1K14-CNTLR-K9     ADM-DB                     NO      2.10      2.10      0.2  
                     ADM-MB                     NO      2.30      2.30      0.2  
                     BIOS                       YES     5.00      5.00      0.0  
                     BIOS-Golden                YES     4.70      0.01      0.0  
                     CpuFpga                    YES     1.17      1.17      0.0  
                     CpuFpgaGolden              YES     1.09      0.01      0.0  
                     SsdIntelS4510              YES    11.51     11.51      0.0  
                     SsdIntelSC2KB              YES     1.30      1.30      0.0  
                     SsdIntelSCKKBGZ            YES     1.30      1.30      0.0  
                     SsdMicron5300              YES     0.01      0.01      0.0  
                     SsdMicron5400              YES     0.02      0.02      0.0  
                     SsdSolidigmSC2KB           YES     1.30      1.30      0.0  
                     SsdSolidigmSCKKB           YES     1.30      1.30      0.0  
                     SsdSRM28480GF1             YES    14.03     14.03      0.0  
                     TamFw                      YES     9.04      9.04      0.0  
                     TamFwGolden                YES     9.04      0.01      0.0  
--------------------------------------------------------------------------------
NCS1K14-CTLR-B-K9    ADM-DB                     NO      2.10      2.10      0.2  
                     ADM-MB                     NO      2.30      2.30      0.2  
                     BIOS                       YES     5.00      5.00      0.0  
                     BIOS-Golden                YES     4.70      0.01      0.0  
                     CpuFpga                    YES     1.17      1.17      0.0  
                     CpuFpgaGolden              YES     1.09      0.01      0.0  
                     SsdIntelS4510              YES    11.51     11.51      0.0  
                     SsdIntelSC2KB              YES     1.30      1.30      0.0  
                     SsdIntelSCKKBGZ            YES     1.30      1.30      0.0  
                     SsdMicron5300              YES     0.01      0.01      0.0  
                     SsdMicron5400              YES     0.02      0.02      0.0  
                     SsdSolidigmSC2KB           YES     1.30      1.30      0.0  
                     SsdSolidigmSCKKB           YES     1.30      1.30      0.0  
                     SsdSRM28480GF1             YES    14.03     14.03      0.0  
                     TamFw                      YES     9.04      9.04      0.0  
                     TamFwGolden                YES     9.04      0.01      0.0  
--------------------------------------------------------------------------------
NCS1K14-EDFA2        CohProbFw                  NO     70.13021  70.13021   0.0  
                     CpuModFw                   NO    251.100   251.100     0.0  
                     OptModFw                   NO      2.04      2.04      0.0  
--------------------------------------------------------------------------------
NCS1K4-1.2T-K9       CpuModFw                   NO    251.100   251.100     0.0  
                     OptModFw                   NO      1.38      1.38      0.0  
--------------------------------------------------------------------------------
NCS1K4-1.2T-L-K9     CpuModFw                   NO    251.100   251.100     0.0  
                     OptModFw                   NO      1.38      1.38      0.0  
--------------------------------------------------------------------------------
NCS1K4-AC-PSU        PO-PriMCU                  NO      2.04      2.04      0.1  
                     PO-SecMCU                  NO      2.06      2.06      0.1  
--------------------------------------------------------------------------------
NCS1K4-AC-PSU-2      PO-PriMCU                  NO      1.03      1.03      0.1  
                     PO-SecMCU                  NO      1.05      1.05      0.1  
--------------------------------------------------------------------------------
NCS1K4-QXP-K9        CpuModFw                   NO    251.100   251.100     0.0  
--------------------------------------------------------------------------------
NCS1K4-QXP-L-K9      CpuModFw                   NO    251.100   251.100     0.0  
RP/0/RP0/CPU0:MOLS_SIT1#           

What to do next

Upgrade all the FPDs using the upgrade hw-module location all fpd all command in the Cisco IOS XR EXEC mode. After upgrade is completed, the Status column shows RLOAD REQ if the software requires reload.

If Reload is required

If the FPGA location is 0/RP0, use the admin hw-module location 0/RP0 reload command. This command reboots only the CPU. As a result, traffic is not impacted. If the FPGA location is 0/0, use the admin hw-module location all reload command. This command reboots the chassis. As a result, traffic is impacted. After the reload is completed, the new FPGA runs the current version.

If Firmware Upgrade Fails

If firmware upgrade fails, use the show logging command to view the details and upgrade the firmware again using the above commands.


Note


You can upgrade the firmware version of power modules, only when both the power modules are present and powered on.

Verify Alarms

You can view the alarm information using the show alarms command.

Procedure


show alarms [ brief [ card | rack | system ] [ location location ] [ active | history ] | detail [ card | rack | system ] [ location location ] [ active | clients | history | stats ] ]

Displays alarms in brief or detail.

Example:

RP/0/RP0/CPU0:RINode1#show alarms brief card location 0/RP0/CPU0 active
Mon Feb 24 14:27:49.802 IST

------------------------------------------------------------------------------------
Active Alarms 
------------------------------------------------------------------------------------
Location        Severity     Group            Set Time                   Description                                                                                                                                                                                                                                                
------------------------------------------------------------------------------------
0               Major        Environ          02/21/2025 14:29:21 IST    Power Group Redundancy lost                                                                                                                                                                                                                                
0/3             Minor        Environ          02/21/2025 14:29:46 IST    TEMP_DX_PCB: Invalid sensor read error.                                                                                                                                                                                                                    
0/3             Minor        Environ          02/21/2025 14:29:46 IST    TEMP_DX_ZYNQ: temperature alarm                                                                                                                                                                                                                            
0/0/NXR0        Minor        Software         02/21/2025 14:29:58 IST    Ots0/0/0/0 - Neighbour not found                                                                                                                                                                                                                           
0/0             Minor        Controller       02/21/2025 14:29:58 IST    Ots0/0/0/0 - OTDR Reflectance Exceeded Absolute Threshold - Receive Direction                                                                                                                                                                              
0/RP0/CPU0      Minor        Software         02/21/2025 14:30:30 IST    SW Upgrade is still allowed as SIA Grace Period is remaining                                                                                                                                                                                               
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_0_85V: low voltage alarm                                                                                                                                                                                                                              
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_2V: low voltage alarm                                                                                                                                                                                                                               
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_8V: low voltage alarm                                                                                                                                                                                                                               
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_2_5V: low voltage alarm                                                                                                                                                                                                                               
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_3_3V: low voltage alarm                                                                                                                                                                                                                               
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_0_85V_MGT: low voltage alarm                                                                                                                                                                                                                          
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_0_9V_MGT: low voltage alarm                                                                                                                                                                                                                           
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_2V_MGT: low voltage alarm                                                                                                                                                                                                                           
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_8V_MGT: low voltage alarm                                                                                                                                                                                                                           
0/3             Critical     Environ          02/21/2025 14:31:55 IST    PGOOD_VTT: low voltage alarm                                                                                                                                                                                                                               
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VIN_7_0V_ST: low voltage alarm                                                                                                                                                                                                                             
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VAUX_3_3V_ST: low voltage alarm                                                                                                                                                                                                                            
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VIN_12V_MOD: low voltage alarm                                                                                                                                                                                                                             
0/3             Critical     Environ          02/21/2025 14:31:55 IST    VMON_1_15V_CDR: low voltage alarm    

Note

 
In the maintenance mode, all the alarms are suppressed and the show alarms command will not show the alarms details. Use the show controllers controllertype R/S/I/P command to view the client and trunk alarms.

Verify Context

The show context command displays core dump context information of NCS 1014.

Procedure


show context

When you excecute the show context command in Cisco IOS XR EXEC mode, the output displays the core dump context information of any process on the NCS 1014 as well as up to 10 last instances.

Example:

RP/0/RP0/CPU0:RINode1#show context 
Mon Feb 24 14:28:32.450 IST

Disclaimer: if exception path is not configured, cores may be found in /misc/disk1/coredumps

node: node0_RP0_CPU0
----------------------------------------------------------------
No context

Verify Core Files

The dir harddisk:/*core.gz command checks for core files of NCS 1014.

Procedure


dir harddisk:/*core.gz

Example:

RP/0/RP0/CPU0:ios#dir harddisk:/*core.gz
Wed Dec 6 04:54:16.336 UTC

Directory of harddisk:/*core.gz
2476 -rw-r--r--. 1 8120038 Oct 30 15:08 cma_server_41264.by.6.20231030-150817.node0_RP0_CPU0.502a7.core.gz