Table Of Contents
Understanding Virtual LAN (VLAN)
Simplification of Adds, Moves, and Changes
Workgroup and Network Security
Understanding VLAN Creation Summary
Moving Affected Ports to New VLAN
Understanding VLAN Deletion Summary
Interpreting VLAN Summary Information
Creating Secondary VLAN and Associating to Primary VLAN
Associating Ports to Secondary VLAN
Understanding Inter-VLAN Routing
Configuring Inter-VLAN Routing on RSM, MSFC, L2/L3 Devices
Configuring Inter-VLAN Routing on External Routers
Understanding VLAN Trunking Protocol Version 3
Support for VTP Version 3 in Campus Manager
Using VLAN Trunking Protocol (VTP)
Dynamic Trunking Protocol (DTP)
Understanding VLAN Port Assignment
Displaying Attribute Summaries
Interpreting Port Attributes Report
Interpreting Device Attributes Report
Usage Scenarios for Managing VLANs
Configuring PVLANs in External Demilitarized Zone
Managing VLANs and VTP
Campus Manager collects data about devices so that you can configure and manage Virtual LANs (VLANs) in your network. You must set up your LMS/Campus Manager server properly to ensure that Data Collection is successfully performed in your network.
The Campus Manager configuration module helps you to manage your VLANs. You can configure and manage VLANs, PVLANs, Trunk, and also assign ports to VLANs.
This chapter contains:
•
Understanding Virtual LAN (VLAN)
•
Interpreting VLAN Summary Information
•
Understanding Inter-VLAN Routing
•
Usage Scenarios for Managing VLANs
Understanding Virtual LAN (VLAN)
A Virtual Local Area Network (VLAN) allows you to create logical broadcast domains that can span across a single switch or multiple switches, regardless of physical positioning. A VLAN contains a group of devices on one or more LANs.
These devices are configured in such a way that they can communicate as if they were all on the same network segment. VLANs are based on logical connections instead of physical connections, and hence they are extremely flexible.
VLAN allows you to group ports on a switch to limit unicast, multicast, and broadcast traffic flooding. Flooded traffic originating from a particular VLAN is only flooded out to other ports belonging to that VLAN.
This helps to reduce the size of broadcast domains and it allows groups or users to be logically grouped without being physically located in the same place.
The following topics are covered in this section:
Advantages of VLANs
VLANs provide the following advantages:
•
Simplification of Adds, Moves, and Changes
•
Controlled Broadcast Activity
•
Workgroup and Network Security
Simplification of Adds, Moves, and Changes
Adds, moves, and changes are some of the greatest expenses in managing a network. Many moves require re-cabling and almost all moves require new station addressing and hub and router re-configuration.
VLANs simplify adds, moves, and changes. VLAN users can share the same network address space regardless of their location.
If a group of VLAN users move but remain in the same VLAN connected to a switch port, their network addresses do not change.
If a user moves from one location to another but stays in the same VLAN, the router configuration does not need to be modified.
Controlled Broadcast Activity
Broadcast traffic occurs in every network. Broadcasts can seriously degrade network performance or even bring down an entire network, if the network is not properly managed.
Broadcast traffic in a particular VLAN is not transmitted outside that VLAN. This substantially reduces overall broadcast traffic, frees bandwidth for real user traffic, and lowers the vulnerability of the network to broadcast storms.
You can control the size of broadcast domains by regulating the size of their associated VLANs and by restricting both the number of switch ports in a VLAN and the number of people using the ports.
You can also assign VLANs based on the application type and the amount of application broadcasts. You can place users sharing a broadcast-intensive application in the same VLAN group and distribute the application across the network.
Workgroup and Network Security
You can use VLANs to provide security Firewalls, restrict individual user access, flag any unwanted network intrusion, and control the size and composition of the broadcast domain.
You can:
•
Increase security by segmenting the network into distinct broadcast groups.
•
Restrict the number of users in a VLAN.
•
Configure all unused ports to a default low-service VLAN.
VLAN Components
The VLAN components are:
•
Switches that logically segment the end stations connected to it.
Switches are the entry point for end-station devices into the switched domain and provide the intelligence to group users, ports, or logical addresses into common communities of interest. LAN switches also increase performance and dedicated bandwidth across the network.
You can group ports and users into communities using a single switch or connected switches. By grouping ports and users across multiple switches, VLANs can span single-building infrastructures, interconnected buildings, or campus networks.
Each switch can make filtering and forwarding decisions by packet and communicate this information to other switches and routers within the network.
•
Routers that extend VLAN communication between workgroups.
Routers provide policy-based control, broadcast management, and route processing and distribution. They also provide the communication between VLANs and VLAN access to shared resources such as servers and hosts.
Routers connect to other parts of the network that are either logically segmented into subnets or require access to remote sites across wide area links.
•
Transport protocols that carry VLAN traffic across shared LAN .
The VLAN transport enables information exchange between interconnected switches and routers on the corporate backbone. This backbone acts as the aggregation point for large volume of traffic.
It also carries end-user VLAN information and identification between switches, routers, and directly attached servers. Within the backbone, high-capacity links with high-bandwidth carry the traffic throughout the enterprise.
Using VLANs
You can use Campus Manager to create, modify, and delete VLANs. You can use the Topology Services to create Ethernet VLANs.
Campus Manager allows you to modify most of the VLAN characteristics that were entered when you created the VLAN, such as purpose, description, and LANE services.
The following sections brief on the types of VLANs supported by Topology Services:
•
Ethernet VLAN (See Ethernet VLANs)
•
Private VLANs (See Understanding Private VLAN)
Configuring VLANs
You can configure VLANs using VLAN Configuration wizard.
Creating VLAN
To create VLANs, the VLAN Configuration wizard directs you through:
1.
Selecting Devices or Entities
5.
Understanding VLAN Creation Summary
Deleting VLAN
To delete VLANs, the VLAN Configuration wizard directs you through:
2.
Moving Affected Ports to New VLAN
3.
Understanding VLAN Deletion Summary
Selecting Devices or Entities
You must select the devices or entities to be included in the VLAN. Domain Selector helps you to select devices in Switch Clouds and VTP Domains.
To select devices or entities for a VLAN:
Step 1
Select Campus Manager > Configuration > VLAN Configuration.
The VLAN Configuration page appears.
Step 2
Select the devices using the Device Selector or the Domain Selector from the VLAN Configuration dialog box.See Table 10-1
Step 3
Either:
a.
Click Create to create VLANs.
The Create VLAN page appears.
b.
Go to Creating VLANs.
Or
a.
Click Delete to delete the VLANs.
The Select VLAN to Delete page appears.
b.
Go to Deleting VLANs.
Creating VLANs
After you select devices using the Device Selector or the Domain Selector and click Create in the VLAN Configuration page, the Create VLAN page appears. For more details, see Selecting Devices or Entities.
You must enter the details as described in the Table 10-2.
Table 10-2 Create VLAN Field Description
Field DescriptionVLAN Name
Enter a name for the new VLAN.
VLAN Index
Enter a number between 1 and 1024 to identify the VLAN.
Create on all transparent switches
Check the checkbox to include all switches that are VTP transparent.
VTP transparent switches do not send VTP updates and do not act on VTP updates received from other switches.
This checkbox is available only for VTP domain based VLAN creation. For more details on this, see Creating VLANs on Transparent Devices
Copy running to start-up config
Check the checkbox to copy the running configuration to the start-up configuration.
Click any of the following:
•
Next to continue.
The Assign VLANs to Port page appears. For details, see Assigning Ports to VLANs.
Assigning ports to VLANs cannot be done for more than 100 devices at a time, since it results in memory issues. If you have selected more than 100 devices, click Finish to save VLAN creation. Do VLAN port assignment for 100 devices at a time.
•
Cancel to exit.
•
Finish to save changes.
VLANs are created on the specified devices and the initial VLAN Configuration page appears.
Creating VLANs on Transparent Devices
When you create VLANS without checking the Create On All Transparent Switches option in the VLAN creation page, the following is the behaviour of Campus Manager:
When you create VLANS with the Create On All Transparent Switches option in the VLAN creation page, the following is the behaviour of Campus Manager:
In the above tables, VTPv2 refers to VTP version 2 and VTP v3 refers to VTP version 3.
Assigning Ports to VLANs
A VLAN created in a management domain remains unused until you assign one or more switch ports to the VLAN.
The Assign VLANs to Port page appears after you create the VLAN name and index.
To assign ports to VLANs:
Step 1
Select Campus Manager > Configuration > VLAN Configuration.
The VLAN Configuration page appears.
Step 2
Select device or domain from the VLAN Configuration page.
Step 3
Click Create.
Step 4
Enter VLAN Name and VLAN Index in the Create VLAN page and click Next.
The Assign Ports to VLAN page appears.
Step 5
Select the ports and click Next.
Table 10-3 describes the entries in the Assign Ports to VLAN page.
Table 10-3 Assign Ports to VLAN Page Field Description
Field DescriptionVLAN
Displays the name of the new VLAN.
Filter
Select any of the following criteria based on which you want to filter the list:
•
Link
•
Port
•
Device Name
•
Device Address
•
Port Status
•
VLAN Index
•
VLAN Name
•
Association type
Or enter * or leave the field blank and click Filter to get all the records.
Advanced Filter
Click Advanced Filter to open Advanced Filter dialog box. Advanced filtering allows you to search ports using more search criteria.
For more details on Advanced Filter, see Advanced Filter.
Column
Link
Shows whether the port is connected to a switch or not. The value can either be True or False.
Port
Name of the port.
Device Name
Name of the device to which the port belongs to.
Device Address
IP address of the device to which the port belongs to.
Port Status
Status of the port. Shows whether the port is active or down.
VLAN Index
Index number for the VLAN to which the port belongs to.
VLAN Name
Name of the VLAN to which the port belongs to.
Association Type
Type of VLAN association.
Step 6
Click any of the following:
•
Next to continue.
The Disallow VLAN on Trunks page appears.
•
Back to modify the Create VLAN page.
•
Cancel to exit.
•
Finish to save changes.
VLANs are created on the specified devices, selected ports are assigned to new VLAN and the initial VLAN Configuration page appears.
For more details, see Disallowing VLAN on Trunks.
Advanced Filter
The Advanced Filter allows you to filter and choose the ports using various parameters and criteria, for assigning the ports to the VLAN. Table 10-4 describes the fields in the Filter Ports Window, when you click Advanced Filter from the Assign Ports to VLAN Window.
Click any of the following:
•
More to add filter.
•
Fewer to remove filter from the existing filters.
You can add or remove only one filter at a time.
•
Filter to filter the ports based on the values for the Parameters.
Disallowing VLAN on Trunks
You can select the links on which you do not want to allow Trunking in the newly created VLAN. After you Assign the ports to the VLAN (See Assigning Ports to VLANs), the End-to end VLAN wizard directs you to Disallow VLAN on Trunks page.
To disallow trunking on the links in your VLAN, check the checkboxes corresponding to those links, and click Next. The VLAN Creation Summary page appears.
Clicking Back takes you to the Assign Ports to VLAN page, where you can modify the port assignment.
Clicking Finish saves the changes and takes you to the initial VLAN Configuration page.
For more details, see Understanding VLAN Creation Summary.
Table 10-5 describes the fields in the Disallow VLAN on Trunks page.
Understanding VLAN Creation Summary
The VLAN Creation Summary page summarizes the operations that you performed through the VLAN Configuration wizard. The Summary provides the following information:
•
VTP Domain—Lists the VTP domains.
•
Summary—Lists different parameters that you have entered.
–
VLAN Creation Parameters—Lists the VLAN name and index, and the value of the parameters Create on all transparent switches and Copy running-config to startup-config.
–
VLAN Port Assignment Parameters—Lists the VLAN name and index, and ports to which the VLAN is assigned to.
–
VLAN Trunk Configuration Parameters—Lists the Trunks on which the VLAN is allowed or disallowed.
Example:
VLAN Creation ParametersVLAN Name: TestVLAN Index: 912Create on all transparent switches : trueCopy running-config to startup-config : true-----------------------------------------VLAN Port Assignment ParametersVLAN Name: TestVLAN Index: 912Operation: Assign the VLAN to selected port(s)Port : Fa4/28Device: 10.77.209.43Device Address: 10.77.209.43------------------------------------------VLAN Trunk Configuration ParametersVLAN Name: TestVLAN Index: 912Operation: Disallow VLAN on selected Trunk(s)Trunk: 10.77.209.52:2/1 => 10.77.209.61:2/25Trunk: 10.77.210.211#2:Gi0/2 => 10.77.210.204:Gi1/0/24Review the Summary, and click Finish to create the new VLAN, or click Back to modify the Disallow VLAN on Trunks page, or click Cancel to exit.
Deleting VLANs
You can delete the VLANs configured on the devices in your network. The VLAN Configuration wizard directs you to delete a VLAN.
Step 1
Select Campus Manager > Configuration > VLAN Configuration.
The VLAN Configuration page appears.
Step 2
Select devices or entities from the VLAN Configuration page.
For more details on selecting the devices, see Selecting Devices or Entities.
Step 3
Click Delete.
The Select VLAN to Delete page appears.
Table 10-6 describes the fields in the Select a VLAN to Delete dialog box.
Step 4
Click any of the following:
•
Next to continue.
The Move Affected Ports to New VLAN page appears. For more details, see Moving Affected Ports to New VLAN.
•
Cancel to exit.
The VLAN configuration appears.
•
Finish to save changes.
The selected VLANs are deleted from the devices. The ports in the deleted VLAN are automatically assigned to the default VLAN. The VLAN configuration page appears.
Moving Affected Ports to New VLAN
When you delete a VLAN, any port assigned to that VLAN becomes inactive. Such ports remain associated with the VLAN (and thus inactive), until you assign them to a new VLAN. You can move affected ports to a new VLAN using Campus Manager.
You can move the ports in the VLAN you want to delete, to a new VLAN, only after you select the VLAN you want to delete. For more details on selecting a VLAN to delete, see Deleting VLANs.
To move affected ports to a new VLAN:
Step 1
Select Campus Manager > Configuration > VLAN Configuration.
The VLAN Configuration page appears.
Step 2
Select devices or entities from the VLAN Configuration page.
For more details on selecting the devices, see Selecting Devices or Entities.
Step 3
Click Delete.
The Select VLAN to Delete page appears.
Step 4
Select the radio button corresponding to the VLAN you want to delete and click Next.
The Move Affected Ports to New VLAN appears.
Table 10-7 describes the fields in the Move Affected Ports to new VLAN page.
Step 5
Select the new VLAN from the Move affected ports to new VLAN drop-down menu.
If you do not select any VLAN, the affected ports are moved to the default VLAN—VLAN 1.
Step 6
Click any of the following:
•
Next to continue.
The VLAN Deletion Summary page appears. For more details, see Understanding VLAN Deletion Summary.
•
Back to modify the Select VLAN to Delete page.
•
Cancel to exit.
The VLAN configuration appears.
•
Finish to save changes.
The selected VLANs are deleted from the devices. The ports in the deleted VLAN are assigned to the VLANs selected by you. The VLAN configuration appears.
Understanding VLAN Deletion Summary
The VLAN Deletion Summary page summarizes the operations that you performed through the VLAN Configuration wizard to delete the VLAN. The Summary provides the following information:
•
VLAN Deletion—Lists the domain name, name of the VLAN that is deleted, and the VLAN ID.
•
Operation: Move the affected Ports to another VLAN—Lists the name and ID of the new VLAN to which the ports have been moved, and lists the details of the ports including the name and IP address of the device.
Example:
VLAN Deletion:===================VLAN Domain :DMZ_10.77.209.43(T)VLAN Deleted :VLAN0002VLANId : 2------------------------------------------Operation: Move the affected Ports to another VLANNew VLAN Name :internal VLAN 4New VLAN Id :4Port:Gi1/6Device :172.20.118.182Device Address :172.20.118.182-------------------------------------------Review the Summary and click Finish to delete the VLAN, or click Back to modify the Select VLAN to Delete page, or click Cancel to exit.
Creating Ethernet VLANs
You can use Topology Services to create Ethernet VLANs (which is the typical VLAN design). For details, see Ethernet VLANs.
Ethernet VLANs
An Ethernet VLAN is the typical VLAN design. This consists of a logical group of end-stations, independent of physical location on an Ethernet network. Catalyst switches support a port-centric or static VLAN configuration.
All end stations that are connected to ports Ethernet VLANs belonging to the same VLAN, are assigned to the same Ethernet VLAN.
Creating Ethernet VLANs
Before you create Ethernet VLANs, you must create a VTP domain in your network.
Your login determines whether you can use this option.
To create Ethernet VLANs in your network:
Step 1
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a VTP domain from the Tree View.
Step 3
Select Tools > VLAN Management > Create > Ethernet from the menu.
The VLAN Creation wizard appears. For more details, see Creating VLANs
Interpreting VLAN Summary Information
To display summary information about the VLANs in your network:
From Tree View in Topology Services, open a VTP domain and select a VLAN. The Summary information is displayed in the right pane of the Topology services window. See Table 10-8 to interpret this information.
![]()
Note
Information on Bridge Number and Ring Number are not applicable to Ethernet VLANs.
Displaying VLAN Reports
Campus Manager allows you to generate VLAN reports for devices, switch clouds, or VTP domains.
Step 1
Select Campus Manager > Reports > Report Generator.
The Report Generator page appears.
The left drop-down list displays Campus Manager Reports.
Step 2
Select VLAN from Select a Report drop-down list.
The VLAN page appears with the following information. See Table 10-9:
Step 3
Click Submit to generate the report. The VLAN reports window appears.
Or
Click Reset to change the settings.
You can open VLAN reports page from Topology Services.
To open VLAN reports from Topology Services:
Step 1
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a view that contains the device, switch cloud, or the VTP Domain for which you want to view the report.
This view is in the Tree View in the Topology Services Main Window.
Step 3
Select Reports > VLAN Report from the menu.
or
Right-click the VTP Domain or the device, and select Display View.
The Network Topology window appears.
Step 4
Select the device or the switch cloud.
Step 5
Right-click and select VLAN Report from the popup menu.
or
Select Reports > VLAN Report.
The VLAN Report window appears.
Interpreting VLAN Reports
The following information is displayed at the top of the report:
•
Device Name
•
Device IP
•
Device Type
•
Domain
Table 10-10 describes the fields in VLAN Report.
Understanding Private VLAN
A Private VLAN (PVLAN) is a VLAN that isolates devices at Layer 2 (L2), from other ports within the same broadcast domain or subnet. PVLAN segregates traffic at L2 and converts a broadcast segment into a non-broadcast multi-access segment.
PVLANs can stop L2 connectivity between end stations on a switch without distributing them into different IP subnets, thus preventing wastage of IP addresses.
You can also assign a specific set of ports within a PVLAN, and thus control the connectivity among them. You can configure PVLANs and normal VLANs on the same switch.
This topic contains:
Types of Private VLAN Ports
The ports in a private VLAN are categorized as:
Promiscuous Ports
Promiscuous port communicates with all other interfaces and ports within a PVLAN. Such ports are used to communicate with external routers, local directories, network management devices, backup servers, administrative workstations, etc.
Ports to the routing module in some switches are promiscuous in nature (for example, MSFC).
PVLAN Host Ports
A PVLAN host port is a port connected to a server or an end host that requires Layer 2 (L2) isolation. A host port exists in the PortFast mode and the BPDU Guard feature is enabled on these ports. These ports can be further classified into:
This depends on the secondary VLAN to which the ports belong.
Isolated Ports
Isolated ports are completely isolated in L2, from other ports in the same PVLAN. These ports cannot receive the broadcasts from other ports within the same PVLAN, but receive broadcasts from promiscuous ports.
Privacy for the VLAN is ensured at L2 level by blocking the traffic to all isolated ports, except the promiscuous ports. Broadcasts from an isolated port is always forwarded to all promiscuous ports.
Community Ports
Community ports communicate among themselves and with their promiscuous ports. These ports are isolated at L2 from all other ports in other communities, or isolated ports within their private VLAN. Broadcasts propagate only between associated community ports and the promiscuous port.
PVLAN Trunk Ports
Private VLAN Trunk ports are similar to Host ports that can carry multiple VLANs. A Trunk port carries the primary VLAN and the secondary VLANs to the neighboring switch. The Trunk port is unaware of PVLAN and will carry PVLAN traffic without any special action.
Using Private VLAN
A Private VLAN has four distinct parts:
•
Primary VLAN
Manages the incoming traffic from the promiscuous port to isolated, community, two-way community ports, and all other promiscuous ports, in the same primary VLAN.
•
Isolated VLAN
Isolated ports use this VLAN to communicate to the promiscuous ports. The traffic from an isolated port is blocked from reaching all adjacent ports within its private VLAN, except for its promiscuous ports.
•
Community VLAN
A group of community ports use this unidirectional VLAN to communicate among themselves and to manage the outgoing traffic through the designated promiscuous ports from the private VLAN.
•
Two-way community VLAN
A group of community ports use this VLAN to communicate among themselves. This bidirectional VLAN manages the incoming and outgoing traffic for community ports and Multilayer Switch Feature Cards (MSFC).
Isolated and community VLANs are called secondary VLANs.
While creating private VLANs, you:
•
Must set VTP to Transparent or Off modes, for VTP version 2.
•
Can create PVLAN on primary server, Transparent and Off modes for VTP version 3.
Campus Manager enables you to:
•
Create primary Private VLAN.
•
Create isolated, community or two-way community VLANs.
•
Associate secondary VLANs to primary VLANs.
•
Assign ports to secondary VLANs.
•
Configure promiscuous ports.
Creating PVLAN
To create a Private VLAN, you must designate one VLAN as primary and another as either isolated, community, or two-way community VLAN. Then, you can assign additional VLANs as secondary VLANs.
After creating primary and secondary VLANs you must associate the secondary VLANs to the respective primary VLANs.
Creating a private VLAN involves the following steps:
•
Create primary VLAN
•
Create secondary VLAN
•
Associate secondary VLAN to primary VLAN
•
Associate ports to secondary VLANs
•
Configure promiscuous ports
Creating Primary VLAN
You must create primary VLAN before creating any other secondary VLAN.
To create Primary VLANs:
Step 1
Select Campus Manager > Configuration > PVLAN Configuration.
The PVLAN Configuration page appears.
Step 2
Select Create PVLAN from the TOC.
Or
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 3
Select a VTP domain from the VTP Tree View, under the Managed Domain or Network View.
Step 4
Select Tools > PVLAN Management > Create.
The Create PVLAN page appears.
Step 5
Select the devices using the Device Selector or the Domain Selector.
For more details, see Step 2 of Selecting Devices or Entities.
Step 6
Select Primary from the Private VLAN Type drop-down list.
The Get Primary VLANs tab and the Associated Primary VLAN field is disabled.
Step 7
Enter a name for the VLAN in the VLAN Name field.
Step 8
Enter the VLAN index number for the new Primary VLAN, in the VLAN Index field.
Step 9
Check the check boxes as required:
•
To create private VLAN on all transparent switches.
•
To copy Running to Startup config for IOS switches.
The check box for creating private VLANs on all transparent switches, is enabled only when the VLAN contains a device in transparent mode.
Step 10
Click Create to create primary PVLAN.
![]()
Note
You must create primary VLAN before creating any other secondary VLAN.
Creating Secondary VLAN and Associating to Primary VLAN
After creating a primary VLAN, you can create secondary VLANs. Once you create a secondary VLAN, you must associate that to a primary VLAN.
To do this:
Step 1
Select Campus Manager > Configuration > PVLAN Configuration.
The PVLAN Configuration page appears.
Or
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a view with a VTP domain, which has the devices listed for which you want to create PVLAN.
This view is in the Tree View in the Topology Services Main Window.
Step 3
Select Tools > PVLAN Management > Create.
The Create PVLAN page appears.
Step 4
Select one of the following options from the Private VLAN Type drop-down list:
•
Isolated
•
Community
•
Two-Way Community
Step 5
Select the Associated Primary VLAN.
You can associate a secondary VLAN that you have created to a primary VLAN.
VTP Domain field displays the domain you have chosen.
You may enter the Private VLAN Name that you want to assign.
Step 6
Select the Private VLAN Index.
Step 7
Check the check boxes as required:
•
To create private VLAN on all transparent switches.
•
To copy Running to Startup config for IOS switches.
The check box for creating private VLANs on all transparent switches, is enabled only when the VLAN contains a device in transparent mode.
Step 8
Click Apply to create PVLAN or click Cancel to exit.
Associating Ports to Secondary VLAN
You must associate ports to the secondary VLAN that you have created. You can assign ports to a secondary VLAN as you assign for normal VLANs. For assigning ports to VLANs, see Using VLAN Port Assignment
Configuring Promiscuous Ports
You must associate the promiscuous ports to the PVLANs you have created, to receive traffic from outside the PVLAN.
You can configure only the ports on which Trunking is not enabled.
To configure a Promiscuous Port:
Step 1
Select Campus Manager > Configuration > PVLAN Configuration from the LMS Portal.
The PVLAN Configuration page appears.
Or
From Topology Services Main Window, select the device that has the ports you require and select Tools > VLAN Port Assignment.
The VLAN Port Assignment window appears.
Step 2
Click Configure Promiscuous Ports from the TOC.
The Configure Promiscuous Ports page appears.
Step 3
Select a device or entities from the list using Device Selector or Domain Selector.
Step 4
Click List Ports.
The Port List displays the list of ports on the selected devices.
You can filter the list using the Filter or Advanced Filter.
Step 5
Select the ports from the ports listed in the table.
Step 6
Click Configure.
The Configure Promiscuous Port window appears.
The Port Details table displays:
•
Device Name
•
Port Name
•
Device IP Address
•
IfName
Step 7
Select the VLANs from the list of Available PVLANs.
Step 8
Click Add to add to list of Mapped VLANs.
Or
Click Remove to remove the VLANs from the Map VLANs table.
You can select the Copy Running to Start-up config check-box to copy the running configuration to the start-up configuration.
Step 9
Click Apply to configure.
Deleting PVLAN
To delete PVLAN:
Step 1
Select Campus Manager > Configuration > PVLAN Configuration from the LMS Portal.
Step 2
Click Delete PVLAN in the TOC.
Or
From Topology Services, select Managed Domains > VTP Domains from the Tree View in the Topology Services Main Window.
Step 3
Select the PVLAN which you want to delete.
Step 4
Select Tools > PVLAN Management > Delete.
A VTP Domain Name: Delete Private VLAN Name appears.
Step 5
Click List PVLANs to see a list of PVLANs. See Table 10-11.
Step 6
Select the check box corresponding to the PVLAN you want to delete.
To select all, select the check-box in the table heading.
Step 7
Click Delete.
Understanding Inter-VLAN Routing
Inter-VLAN Routing enables to route the traffic between different VLANs. This feature is required when an end station wants to communicate with another end station in a different VLAN. Devices within a VLAN can communicate with one another without the help of a router.
On the contrary, devices in separate VLANs require a routing device to communicate with one another. Network devices in different VLANs cannot communicate with one another without a router to route the traffic between the VLANs.
In most of the network environments, VLANs will be associated with individual networks or subnetworks. In a switched network, VLANs segregate devices into different collision domains and Layer 3 (L3) subnets.
Configuring VLANs for inter-VLAN routing helps to control the size of the broadcast domain and to keep local traffic local. You can configure one or more routers to route traffic in the network.
Layer 2 switches require a L3 routing device (either external to the switch or in another module on the same chassis).
The new L3 Switches accommodate routing capabilities. The router or the switch receives a packet, determines the VLAN to which it belongs, and sends the packet to the appropriate port on the other VLAN.
Using Inter-VLAN Routing
Configuring Inter-VLAN Routing
Campus Manager supports Inter-VLAN Routing configuration on devices like MSFC, RSM, and external routers with IPv4.
Prerequisite for configuring Inter-VLAN Routing through Campus Manager
Resource Manager Essentials is a prerequisite for configuring Inter-VLAN Routing using Campus Manager. If the server running Campus Manager does not have RME, you can use a remote server, which has the RME application.
If you want to configure Inter-VLAN Routing on a device:
•
Resource Manager Essentials must manage the devices.
•
The device must have the same device name when managed by Campus Manager as well as Resource Manager Essentials.
See the User Guide for Resource Manager Essentials 4.1 for more details on how to manage devices.
Configuring Inter-VLAN Routing on RSM, MSFC, L2/L3 Devices
To configure Inter-VLAN Routing on a VLAN interface:
Step 1
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a device from the Topology Services Tree View, under the Network Views.
Step 3
Right-click the device and select Config Inter-VLAN Routing from the popup menu.
The Configure Inter-VLAN Routing window appears. This window displays the Device Name and the Device IP of the selected device.
Step 4
Select a device interface from Device interface configuration list.
Step 5
Click Edit to edit an existing VLAN configuration.
Or
Click New to configure Inter-VLAN Routing for a new VLAN interface.
You can edit IP Address, Admin Status, and Subnet Mask. See Table 10-12.
Table 10-12 Configuring Inter-VLAN Routing Field Descriptions
Field DescriptionVLAN Interface1
Enter the VLAN interface.
IP Address
Enter the IP address for the interface
Subnet Mask
Enter the subnet mask address.
Admin Status
Select the Admin status:
•
Up
•
Down
1 You can enter the VLAN interface name to create a new interface. You cannot edit an existing VLAN interface.
You can also delete a Device Interface from the list of Interfaces for which you do not want to configure Inter-VLAN Routing.
Step 6
Click Move to Interface Set.
If you want to edit the configuration details again:
a.
Select the VLAN interface from the Interface Set.
b.
Click Delete from Interface Set
c.
Repeat the steps from Step 4.
Step 7
Click Apply.
You can configure Inter-VLAN Routing for more than one VLAN interface, at a time.
The RME Server credentials window appears.
Step 8
Enter RME Server, Server Port, User Name, and Password. See Table 10-13.
Table 10-13 RME Server credentials Field Description
Field DescriptionRME Server
Name of the RME server or the IP address
Server Port1
Enter the port number
User Name
Enter the user name
Password
Enter the password
1 In Campus Manager, 1741 is the default port for http mode and 443 is the default port for SSL (https) mode.
Step 9
Click OK.
Inter-VLAN Routing is configured for all the VLAN interfaces in Interface Set.
Configuring Inter-VLAN Routing on External Routers
To configure Inter-VLAN Routing on a VLAN interface of an external router:
Step 1
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a device from the Topology Services Tree View, under the Network Views.
Step 3
Right-click the device and select Config Inter-VLAN Routing from the popup menu.
The RME Server credentials window appears.
Step 4
Enter RME Server, Server Port, User Name, and Password. See Table 10-14
Table 10-14 RME Server Credentials Field Description
Field DescriptionRME Server
Name of the RME server or the IP address.
Server Port1
Enter the port number.
User Name
Enter the user name.
Password
Enter the password.
1 In Campus Manager 1741 is the default port for http mode and 443 is the default port for SSL (https) mode.
Step 5
Click OK.
The Configure Inter-VLAN Routing window appears.
Step 6
Select a device interface from Device interface configuration list.
Step 7
Click Edit to edit an existing VLAN configuration.
Or
Click New to configure Inter-VLAN Routing for a new VLAN interface.
You can edit IP Address, Admin Status, Encapsulation, and Subnet Mask. See Table 10-15
Table 10-15 Configuring Inter-VLAN Routing Field Descriptions
Field DescriptionVLAN Interface1
Enter the VLAN interface.
IP Address
Enter the IP address for the interface.
Sub-Interface ID
Enter the ID for the sub-interface.
Admin Status
Select the Admin status:
•
Up
•
Down
Encapsulation
Select the encapsulation:
•
dot1Q
•
ISL
Subnet Mask
Enter the subnet mask address.
1 You can enter the VLAN interface name to create a new interface. You cannot edit an existing VLAN interface.
You can also delete a device interface from the list of interfaces for which you do not want to configure Inter-VLAN Routing.
Step 8
Click Move to Interface Set.
If you want to edit the configuration details again:
a.
Select the VLAN interface from the Interface Set.
b.
Click Delete from Interface Set
c.
Repeat the steps from Step 2.
Step 9
Click Apply.
You can configure Inter-VLAN Routing for more than one VLAN interface, at a time.
Inter-VLAN Routing is configured for all VLAN interfaces in the Interface Set.
VLAN Trunking Protocol
VLAN Trunking Protocol (VTP) is a Layer 2 multicast messaging protocol that maps VLANs across all media types and VLAN tagging methods between switches. In this way it maintains the VLAN configuration consistency throughout a network.
VTP reduces the effort in adding, deleting, or renaming a VLAN at each switch, when the VLAN extends to other switches in the network.
VTP minimizes misconfigurations and configuration inconsistencies that can result in a number of problems, such as duplicate VLAN names, incorrect VLAN-type specifications, and security violations.
With VTP, you can make configuration changes centrally on one switch and have those changes automatically communicated to all the other switches in the network.
The major function of VTP is to distribute VLAN information. You must configure VTP before you configure any VLAN.
Using VTP, each switch in server mode displays the following:
•
Management domain on the Trunk ports
•
Configuration revision number
•
VLANs and their specific parameters.
For more details on VLAN, see Understanding Virtual LAN (VLAN), and for VTP Domains, seeVTP Domains.
This topic contains:
•
Understanding VLAN Trunking Protocol Version 3
•
Using VLAN Trunking Protocol (VTP)
VTP Domains
A VTP domain is made up of one or more interconnected devices that share the same VTP domain name. A switch can be configured to be in only one VTP domain, and each VLAN has a name that is unique within a management domain.
Typically, you use a VTP domain to ease administrative control of your network or to account for physical boundaries within your network. However, you can set up as many or as few VTP domains as are appropriate for your administrative needs.
Consider that VTP is transmitted on all Trunk connections, including ISL, IEEE 802.1Q, 802.10, and LANE.
VTP Domains display and monitor the details of the VLANs in your network. Sometimes includes special cases labeled NULL or NO_VTP.
•
NULL—Lists devices that are in transparent mode and that support VTP, but do not have configured domain names. Each of these devices is identified in the list by its IP address.
•
NO_VTP—Lists devices that do not support VTP. Each of these devices is identified in the list by its IP address.
However, devices which do not support VTP but support VLANs (for example, Catalyst 2900XL Standard Edition switches) are placed in the NO_VTP domain.
The devices that do not support VLANs and VTP (for example, Catalyst 1900 Standard Edition switches) are placed in the domain category of the neighbor device.
Components of VTP Domains
Within a VTP domain, you can configure switches as follows:
•
Server—VTP servers advertise their VLAN configuration to other switches in the same VTP domain and synchronize their VLAN configuration with other switches based on advertisements received over Trunk links. VTP server is the default mode.
•
Client—VTP clients operate in the same way as VTP servers. However, you cannot create, change, or delete VLANs on a VTP client. VTP clients also do not broadcast VTP advertisements like the VTP servers do.
•
Transparent—VTP transparent switches do not participate in VTP. A VTP transparent switch does not display its VLAN configuration and does not synchronize its VLAN configuration based on received advertisements.
Your VTP domain structure influences the behavior of Topology Services.
Understanding VLAN Trunking Protocol Version 3
VTP version 3 can distribute a list of opaque databases over an administrative domain.
VTP version 3 provides these enhancements to the previous VTP versions:
•
Support for extended VLANs.
•
Support for creating and advertising private VLANs.
•
Support for VLAN instances and MST mapping propagation instances.
•
Allows improved server authentication.
•
Prevents you from adding the wrong database to a VTP domain.
•
Allows interaction with VTP version 1 and VTP version 2.
•
Support for configuring VTP version 3 on a per-port basis.
•
Enables the network to propagate the VLAN database and other databases.
VTP version 3 is a collection of protocol instances. Each instance handles one database, which is associated with a given feature. VTP version 3 runs multiple instances of the protocol by which it handles the configuration propagation of multiple databases that are independent of one another.
Support for VTP Version 3 in Campus Manager
Campus Manager supports the version 3 of VTP. Following are the major features supported in this release:
•
Displays Primary server as a subfolder under the parent VTP domain:
If your network contains devices running VTP version 3, the primary server is displayed as a subfolder under the parent Domain in the VTP Domains. Under Primary server folder, you can find all the server and client modes.
•
Supports devices with VTP set to Off mode:
The devices which are set to Off mode are supported as for the transparent mode devices. The Tree View displays the Off mode devices in subfolder under the parent domain.
•
Provides VTP filters:
Topology Filters contains a filter for devices running VTP version 3 in the Network Topology view for the VTP Domains and VTP Views.
You can enable the filters to view the primary, server, client, transparent, and Off mode devices. The Off mode devices in VTP version 2 and version 3 domains, are displayed under different subfolders of the parent domain, in the Tree View.
When you change the configuration through Campus Manager, the Off mode devices are considered similar to the Transparent mode devices.
For more details, see Figure 10-1.
Figure 10-1 VTP Filters
![]()
•
Supports creating Private VLANs in VTP version 3 environment.
You can create a VLAN or PVLAN using a primary server domain or the parent domain. You can create a VLAN or PVLAN only on the Primary server, Transparent and Off mode devices, in a VTP version 3 environment.
Notes on creating VLAN or PVLAN in VTP version 3 domain using Campus Manager
•
You must select the parent VTP domain folder under the VTP domain Tree to create VLAN or PVLAN.
•
To create VLAN or PVLAN on all transparent switches in the domain, you can check the check box Create VLAN on all transparent switches in the Creating VLAN or PVLAN windows.
For more details, see Creating Ethernet VLANs and Creating PVLAN.
•
You must select the primary domain subfolder under the VTP domain, while creating VLAN and PVLAN on the Primary server mode devices that has clients and secondary servers.
•
You must select Transparent or Off mode subfolders under the parent VTP domain to create VLAN or PVLAN on a single Transparent or Off mode device respectively.
Using VLAN Trunking Protocol (VTP)
Using VLAN Trunking Protocol (VTP), each switch in server mode advertises its management domain on its Trunk ports, its configuration revision number, and its known VLANs and their specific parameters.
Therefore, a new VLAN must be configured on only one device in the management domain, and the information is automatically learned by all other devices (not in VTP transparent mode) in the same management domain.
After a device learns about a VLAN, it receives all frames on that VLAN from any Trunk port and, if appropriate, forwards them to each of its other Trunk ports.
This topic contains:
Displaying VTP Reports
To display a VTP report for the VTP domains in your network.
Step 1
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a VTP domain under the VTP views for which you want to view the report. This view is in the Tree View in the Topology Services Main Window.
The VTP Report, which is the Summary view, appears.
Interpreting VTP Reports
See Table 10-16 to interpret the fields shown in the VT Reports Summary view.
Using VTP Views
VTP Views shows devices that participate in VTP domains. VTP Views also shows the non-VTP devices connected directly to the VTP domain. See Figure 10-2
Figure 10-2 VTP Tree View
![]()
Use the VTP views to:
•
Display Device Attributes
•
Display information about multi-layer switching (MLS) devices in your network. See Displaying MLS Reports
Understanding Trunking
A Trunk is a point-to-point link carrying traffic for several VLANs, and are typically used to connect switches. Instead of configuring several access links to carry multi-VLAN traffic, its economical to do it with a single trunk link.
Trunking is hence a type of configuration on an interface which allows VLANs to span the entire network, instead of just one switch. The Trunked interface that connects to another network device is allowed to pass traffic for multiple VLANs, instead of only one VLAN as in a non-Trunked interface on a switch.
This topic contains:
•
Dynamic Trunking Protocol (DTP)
Trunking Considerations
While using a Trunk, consider the following:
•
VLANs are local database of a switch. VLAN information is not passed between switches.
•
Trunk links provide VLAN identification for frames traveling between switches.
•
You can use either of the two Ethernet Trunking mechanisms: ISL and IEEE 802.1Q.
•
Trunks carry traffic from all VLANs to and from the switch by default. However, they can be configured to carry only specified VLAN traffic too.
•
Trunk links must be configured to allow Trunking on each end of the link.
Dynamic Trunking Protocol (DTP)
Dynamic Trunking Protocol (DTP) is a Cisco proprietary protocol. Trunk negotiation is managed by the DTP on a link between two devices. DTP is also used for negotiating the type of Trunking encapsulation to be used.
Dynamic Trunking is the ability to negotiate the Trunking method with the other device, and DTP is a point-to-point protocol that supports auto-negotiation of both ISL and 802.1Q Trunks. DTP sends the VTP domain name in a DTP packet.
Therefore, if you use DTP, and if the two ends of a link belong to a different VTP domain, the Trunk will not function.
The Catalyst operating system options of auto, desirable, and on, and the IOS options of dynamic auto, dynamic desirable, and trunk, configure a Trunk link using DTP. If one side of the link is configured to Trunk and sends DTP signals, the other side of the link will dynamically begin to Trunk, if the options match correctly.
To enable Trunking and not send any DTP signaling, you can use the option nonegotiate for switches that support that function. If you want to disable Trunking completely, you can use the off option for a Catalyst operating system switch or the no switchport mode trunk command on an IOS switch.
DTP is a second generation Dynamic Inter-Switch Link Protocol (DISL) and allows the Cisco Catalyst devices to negotiate whether to use 802.1Q encapsulation. DISL and DTP do not negotiate Trunking in case of EtherChannel—they only negotiate whether to enable Trunking.
Trunk Encapsulation
The following Trunking encapsulations are available on all Ethernet interfaces:
•
Inter-Switch Link (ISL)—A Cisco-proprietary Trunking encapsulation.
•
802.1Q—An industry-standard Trunking encapsulation.
Trunk Characteristics
Table 10-17 shows the DTP signaling and the characteristics of each mode.
Encapsulation Types
The encapsulation type allows you to specify whether ISL or 802.1q should be used for Trunking. The parameter is only relevant if the module you are using is able to use both types of encapsulation. The parameter can have three different values as shown in table below.
Creating Trunk
To create trunk for a port:
Step 1
Select Campus Manager >Configuration > Trunk Configuration from the LMS Portal.
The Create Trunk page appears.
Step 2
Select the device or domain from the list, and click Show Links.
The Available Links pane displays the links for each device that you have selected. Table 10-18 describes the fields in the Available Links pane.
Step 3
Click the radio button corresponding to the link to select link for which you want to create trunk.
Step 4
Click Create Trunk.
Or
From Topology Map, right-click the link for which you want to create trunk, and select Create Trunk from the popup menu.
The Create Trunk window appears.
Table 10-19 describes the fields in the Create Trunk page.
To copy the running configuration to start-up configuration, select Copy Running to Start-up Config check-box .
Step 5
Click Create to create the Trunk or click Close to exit.
After you click Create, it will be idle for 2 minutes to see if the device goes down on setting the port to trunking mode. After 2 minutes, if the creation of trunk is successful, Data Collection for these devices is triggered.
Only after the completion of Data Collection, you can see the newly configured trunk ports in the Modify Trunk Attributes page.
![]()
Note
If the trunk link is configured in a port that flaps between blocking and non-blocking states due to STP, then the port will be listed in both Create Trunk page and Modify Trunk Attributes page.
To know whether the port is trunking or not, enable logging in the device and see the log messages.
Modifying Trunk Attributes
To modify trunk attributes:
Step 1
Select Campus Manager > Configuration > Trunk Configuration from the LMS Portal.
Step 2
Click Modify Trunk Attributes from the TOC.
The Modify Trunk Attributes page appears.
Step 3
Select devices from the device list, and click Show Trunks.
The trunks configured on the devices are listed in the Trunk List. See Table 10-20.
Step 4
Select the radio-buttons corresponding the trunk you want to modify, and click Modify Trunk.
The Modify Trunk window appears.
The Device Information pane displays the device IP address and the port number of all the devices you have selected.
Step 5
Select the Trunk Settings
a.
Select Encapsulation:
–
Dot1Q
–
ISL
–
Negotiate
b.
Mode
Campus Manager 3.3 supports only the Desirable mode.
Step 6
Configure VLANs on Trunk.
•
Allow VLAN(s)—Enter VLAN IDs of the VLANs, which must pass through the Trunk, in a range between 1 to 1005 and 1025 to 4094. The other VLANs are not supported for Trunking. * indicates that the VLANs were previously disallowed.
•
Disallow VLAN(s)—Enter VLAN IDs of the VLANs, which must not pass through the Trunk, in a range between 1 and 4096.
Use the Add or Remove buttons to allow or disallow VLANs.
To copy the running configuration to start-up configuration, select Copy Running to Start-up Config check-box.
Step 7
Click Modify.
EtherChannel
EtherChannel is a technology that bundles individual Fast Ethernet and Gigabit Ethernet links into a single logical link that would provide higher bandwidth. EtherChannels thus enable you to aggregate up to Gigabit Ethernet connections, providing up to 16 Gbps of bandwidth (in full duplex mode).
The channel is treated as a single logical connection between two switches. If one of the connections fails in the EtherChannel, the other connections will be operating so that the connection is not down.
This topic contains:
Understanding EtherChannel
EtherChannel provides incremental Trunk speeds between Fast Ethernet (FE) and Gigabit Ethernet (GE) by grouping multiple equal-speed ports into a logical port channel. EtherChannel combines multiple FEs up to 800 Mbps or GEs up to 8 Gbps, providing fault-tolerant, high-speed links between switches, routers, and servers.
Campus Manager supports only PAgP, the aggregation protocol. When a user selects a port or link for configuring EtherChannel, the user is prompted with all available ports that can participate in the channel (Ports that are directly connected between devices).
Admin Group ID attribute for each port is also provided under group attribute. User can change them accordingly to choose which ports need to aggregate into a channel.
All ports that have same group value will participate in channel. Campus Manager supports only the Desirable mode for EtherChannel configuration.
Campus Manager does not support EtherChannel configuration between a switch and router.
Using EtherChannel
Campus Manager allows you to:
•
Aggregate multiple links between switches into one or more EtherChannels.
•
Configure frame distribution parameters for EtherChannel load balancing.
Configuring EtherChannel
To configure EtherChannel:
Step 1
Select Campus Manager > Visualization > Topology Services from the LMS Portal.
The Topology Services Main Window appears.
Step 2
Select a view that contains the devices for which you want to configure EtherChannel.
This view is in the Tree View in the Topology Services Main Window.
Step 3
Right-click the view and select Display View from the popup menu.
The Network Topology View window appears.
Step 4
From the Network Topology View select the link on which you want to configure EtherChannel.
Step 5
Right-click the link and select Configure EtherChannel.
The EtherChannel Configuration window appears.
Protocol field displays PAgP. Port Aggregation Protocol (PAgP) is the Protocol that is supported for configuring EtherChannel.
Step 6
Select one of the Distribution Protocols from the drop-down menu:
•
ip
•
mac
•
port
•
leave default
Select leave default when you do not want to configure distribution protocols.
The Channel Mode field displays the mode of the port.
Campus Manager supports only the Desirable mode for EtherChannel configuration.
Step 7
Select one of these Distribution Address Types from the drop-down menu:
•
source
•
destination
•
both
•
leave default
Select leave default when you do not want to configure distribution address type.
Step 8
Select the link for which you want to configure EtherChannel.
Step 9
Click Copy Running to StartUp config for IOS switches, if required.
Step 10
Click Apply to continue or click Close to exit.
VLAN Port Assignment
VLAN Port Assignment is an application that displays device, port, and related VLAN information for an associated VTP domain in a tabular format and helps you manage ports on your network's VLANs.
Use VLAN Port Assignment to:
•
Assign or move ports to a VLAN.
•
View port, device, and Trunk attributes.
•
View and find port information in a VTP domain.
•
Configure VLANs on a Trunk.
•
Show and highlight a selected device or VLAN on a selected VTP domain.
![]()
Note
Assigning ports to VLANs cannot be done for more than 100 devices at a time, since it results in memory issues. Do VLAN port assignment for 100 devices at a time.
This topic contains the following sections:
•
Understanding VLAN Port Assignment
•
Starting VLAN Port Assignment
Prior to using VLAN Port Assignment, you should understand the concepts of VLANs and VTP domains. For more details on this, see:
•
Understanding Virtual LAN (VLAN)
Understanding VLAN Port Assignment
To enable end-user ports to participate in a specific VLAN, you must first assign the ports. You assign ports to specified VLANs. The VLANs allow the ports to share the same broadcasts.
Ports that are not assigned to the VLAN cannot share these broadcasts. For more information about VLANs, see Understanding Virtual LAN (VLAN).
For VLAN Port Assignment to work correctly, Campus Server must discover the network. Campus Server requires a properly configured network to complete network discovery.
For information on the various settings, see Viewing Campus Manager Home Page.
VLAN Port Assignment queries the ANI database based on criteria you enter.
After you submit the query, VLAN Port Assignment displays the device, port, and related VLAN information for an associated VTP domain. This is displayed in a tabular format.
You can use VLAN Port Assignment to:
•
View and find port information in a VTP domain
•
View port, device, and Trunk Attributes
•
Show and highlight a selected device or VLAN in the VTP domain view
Starting VLAN Port Assignment
To start VLAN Port Assignment:
Step 1
Verify that your network is set up properly.
Step 2
Verify that the Campus Manager server is set up properly and running.
See Analyzing ANI Server for more details.
Step 3
Select Campus Manager > Configuration > VLAN Port Assignment from the LMS Portal.
Or
Select Topology Services > Tools > VLAN Port Assignment.
If you are prompted to install the Java plug-in, you can download and install the plug-in using the displayed installation screens. The next time you start the application, it will automatically use the plug-in.
Using VLAN Port Assignment
To assign ports to a VLAN:
Step 1
Select Campus Manager > Configuration > VLAN Port Assignment from the LMS Portal.
Or
Select Topology Services > Tools > VLAN Port Assignment.
The VLAN Port Assignment page appears.
Step 2
Select device or domain from the list using Device Selector or Domain Selector.
Step 3
Click List Ports.
A list of ports in the selected devices or entities appears under the Port List. See Table 10-21 for the Port List :
Table 10-21 Port List Field Description
Field DescriptionFilter
•
Device Name
•
Device Address
•
Link
•
Port
•
Port Status
•
Port Description
•
VLAN Name
•
VLAN Index
•
Association Type
Enter the filter string, and click Filter to filter the list based on the inputs. Leave this field blank to list all ports.
Advanced Filter
Click Advanced Filter to open Advanced Filter dialog box. Advanced filtering allows you to search ports using more search criteria.
For more details on Advanced Filter, see Advanced Filter.
Columns
Link
Shows whether the port is connected to a switch or not. The value can either be True or False.
Port
Name of the port.
Device Name
Name of the device to which the port belongs to.
Device Address
IP address of the device to which the port belongs to.
VLAN Name
Name of the VLAN to which the port belongs to.
Port Status
Status of the port. Shows whether the port is active or down.
Port Description
Description for the port.
Example: Intra-area 0.2.0.0 Resilient link
VLAN Index
Index number of the VLAN to which the port belongs to.
Association Type
Type of Association.
Step 4
Select a VLAN from the VLAN drop-down list.
To copy the running configuration to the start-up configuration, select Copy running to start-up config check-box.
Step 5
Click Assign.
Configuring Trunk Attributes
Your login determines whether you can use this option. You must have either Network Administrator or System Administrator privileges.
To configure Trunk Attributes:
Step 1
Select Campus Manager > VLAN Port Assignment from CiscoWorks desktop.
Or
From Topology Services Main Window, right-click a trunk link from a network view and select VLAN Port Assignment from the popup menu.
Step 2
In the VLAN Port Assignment window, select the VTP domain and enter appropriate search criteria, if necessary.
Step 3
Select the row that contains the Trunking port. A port is a trunking port if the isTrunk field contains a check mark.
Step 4
Select Reports > Trunk Attributes.
To interpret this information, see Table 10-24.
Step 5
Enter a range of ISL indexes between 1 and 4096 in the Allow VLAN(s) field to specify VLANs that you want to allow on this Trunk.
The range of ISL indexes from one to 4096 is applicable only if the device supports 4096 VLANs.
Step 6
Enter a range of ISL indexes between 1 and 1024 in the Disallow VLAN(s) field to specify VLANs that you want to prevent from using this Trunk.
If you enter numbers into both fields, the ISL indexes that you are disallowing will take precedence over ISL indexes that you are allowing. For example, if you allow 1-1024 and disallow 1-100, VLANs with ISL indexes of 101-1024 will be allowed.
Step 7
Click Apply to configure these attributes.
Displaying Attribute Summaries
The following topics describe how to view status information about ports, devices, and trunks in your network:
•
Interpreting Port Attributes Report
•
Interpreting Device Attributes Report
•
Interpreting Trunk Attributes
Displaying Port Attributes
To display information about the status of the ports in your network:
Step 1
Select Campus Manager > Reports > Report Generator.
The Reports Generator page appears.
Step 2
Select Campus Reports from the Select An Application drop-down list.
Step 3
Select Port Attributes from Select a Report drop-down list.
The Port Attributes page appears.
Step 4
Select a device or domain from the list.
Step 5
Select the Scheduling Type.
The default scheduling type is Immediate.
You can set the time and date if you select any of the following scheduling types: Once, Daily, Weekly, Monthly.
Enter a description for your job in the Job Description field and enter the e-mail address to which the details has to be sent.
![]()
Note
Launching immediate Port Attributes reports for more than 500 devices results in an error. You can schedule reports to run for all devices or launch immediate reports for less than 500 devices.
Step 6
Click Submit.
For more information on Port Attributes, see Interpreting Port Attributes Report.
Interpreting Port Attributes Report
To view the Port Attributes report for a device, select the device from the Go To: list. The Go To: list contains the device name and device IP address.
Alternatively, you can scroll the page to view the report for the selected devices.
The Port Attributes report contains the following information for a device:
You can export or print the report.
To export the report to a Common Services server, click the export button at the top right of the page.
To print the page, click the printer icon on the top right of the page.
Displaying Device Attributes
To display information about a specific device.
Step 1
Select Campus Manager > Reports > Report Generator.
The Reports Generator page appears.
Step 2
Select Campus Reports from the Select An Application drop-down list.
Step 3
Select Device Attributes from Select a Report drop-down list.
The Device Attributes page appears.
Step 4
Select a device or domain from the list.
Step 5
Select the Scheduling Type.
The default scheduling type is Immediate.
You can set the time and date if you select any of the following scheduling types: Once, Daily, Weekly, Monthly.
Step 6
Enter a description for your job in the Job Description field and enter the e-mail address to which the details has to be sent.
Step 7
Click Submit.
For more information on Device Attributes, see Interpreting Device Attributes Report.
Interpreting Device Attributes Report
To view the device attributes report for a device, select the device from the Go To: list. The Go To: list contains the device name, device IP address, and the device type.
Report for each device is displayed in a table with the Device Name, Device IP Address, and Device Type as the table heading.
Alternatively, you can scroll the page to view the report for the selected devices.
The device attributes report contains the following information for a device:
Displaying Trunk Attributes
To display information about the status of the trunking ports in your network.
Step 1
Select Campus Manager > Configuration > Trunk Configuration from the LMS Portal.
The Trunk Configuration page appears.
Step 2
Click Modify Trunk Attributes from the TOC.
Step 3
Select device or domain from the list.
Step 4
Click Show Trunks.
A list of trunks appears.
Step 5
Select the radio-button corresponding to a trunk.
Step 6
Click Modify Trunk.
The Modify Trunk Attributes window appears with the trunk attributes.
For more information on Trunk Attributes, see Interpreting Trunk Attributes.
Interpreting Trunk Attributes
See Table 10-24 for details about the fields shown in the Trunk Attributes window.
Troubleshooting Suggestions
Use the information in the Troubleshooting VLAN Port Assignment Table 4-3 to troubleshoot the VLAN Port Assignment application.
Usage Scenarios for Managing VLANs
You can use the following scenarios to manage your network using Campus Manager.
Configuring PVLANs in External Demilitarized Zone
Scenario
Web servers and Domain Name Servers (DNS) are connected to a Demilitarized Zone (DMZ) switch. The DMZ switch is configured with the VTP domain name, DMZ, where the switch is in transparent mode running VTP version 2. The servers belong to the same broadcast domain or VLAN.
Understanding the Scenario
This scenario would help you to isolate Layer 2 devices using PVLAN, and ensure that the DMZ servers do not send data across them, while internal and external hosts access these servers.
DMZ servers must be accessible from external clients as well as from the internal network. DMZ servers eventually needs access to some internal resources, and the servers must not send data across. The servers must not initiate traffic from the DMZ switch to the Internet. The DMZ servers reply only to the traffic from the internal resources.
Understanding Concepts
Campus Manager provides an end-to end solution for configuring Private VLANs, the security feature which Campus Manager provides for managing LANs. You can configure PVLANs using Campus Manager.
You can configure PVLANs in scenarios where Demilitarized Zone (DMZ) switches are configured without adhering to the right policies, leading to potential intrusions into your network.
Demilitarized Zone
Demilitarized Zone is a small subnetwork, which lies between a secure internal network, such as a corporate private LAN, and a non secure external network, such as the public Internet. DMZ contains devices like Web servers, FTP servers, SMTP servers and DNS that are accessible to the Internet traffic.
DMZ servers process incoming requests from the Internet, and initiate connections to certain internal servers or other DMZ segments, such as database servers.
DMZ servers must not send data or initiate any connection to the external networks. This shows that the necessary traffic flows on the basis of a trust model; but the model is not adequately enforced in many networks.
Prerequisites
In this scenario, you need the following applications and tools in Campus Manager.
•
Topology Services
•
PVLAN configuration user interface
•
VLAN Port Assignment
•
Promiscuous port configuration user interface
•
VLAN report
•
Path Analysis
Reproducing Scenario
To set up the scenario you must configure secondary VLAN on the servers, with isolated ports and community ports. The Firewall, the only device within the primary VLAN, must be defined in a primary VLAN with a promiscuous port.
Step 1
Create a primary VLAN: VLAN 100.
Enter VLAN 100 in the Private VLAN Name field to name the primary VLAN. For more details on creating primary VLAN, see Creating Primary VLAN.
Step 2
Create a community VLAN: VLAN 50.
a.
Enter VLAN 50 in the Private VLAN Name field.
b.
Associate VLAN 50 to the primary VLAN, VLAN 100.
For more details on creating secondary VLAN, see Creating Secondary VLAN and Associating to Primary VLAN.
Step 3
Create an isolated VLAN: VLAN 60.
a.
Enter VLAN 60 in the Private VLAN Name field to name the isolated VLAN
b.
Associate VLAN 60 to the primary VLAN, VLAN 100.
For more details on creating secondary VLAN, see Creating Secondary VLAN and Associating to Primary VLAN.
Step 4
Assign ports, which are connected to the Web servers, to the community VLAN 50.
Step 5
Assign ports, which are connected to the DNS servers, to the isolated VLAN 60.
Step 6
Configure the port that connects to the Firewall as a promiscuous port and map the secondary VLAN 50 and VLAN 60 to this promiscuous port. For more details, see Configuring Promiscuous Ports.
After you configure the promiscuous port, the secondary VLANs appear in the Mapped VLANs table.
You have configured promiscuous port and mapped both secondary VLANs to the primary VLAN 100.
If you want to map only the community VLAN 60, you must check the configurations, and map the other isolated VLANs.
Check the Select to Unmap check box and click Apply to unmap the isolated VLAN from primary VLAN. Community VLAN 60 is unmapped from the primary VLAN.
Verifying Configuration
To verify the configuration for this scenario:
Step 1
Select Campus Manager > Visualization > Topology Services from the CiscoWorks Homepage.
The Topology Services Main Window appears.
Step 2
From the Tree View in the Topology Services Main window, verify whether the new PVLANs are listed under DMZ VTP domain in transparent mode.
Primary VLAN 100 is listed as a subfolder under the DMZ domain and the secondary VLAN under the Primary VLAN subfolder. Note that the icon for PVLANs is different from the icon for normal VLANs.
Step 3
Generate VLAN Report for DMZ domain.
Step 4
Verify whether the new primary VLAN and secondary VLANs are listed. The associated primary VLAN is also listed for the secondary VLANs.
Step 5
Select Campus Manager > Diagnostics > Path Analysis from the CiscoWorks Homepage.
Step 6
To confirm that the PVLAN configuration is functioning, you can:
a.
Run a trace between the Web servers. The resultant traces must be successful.
b.
Run a trace between any Web server and the DNS. The resultant trace must fail.
c.