New and Changed Information

The New and Changed Information section provides an overview of the major updates and enhancements introduced in this release of the Cisco Nexus Dashboard.

Table 1. New and Changed Features Comparison Table

Feature

Description

Where Documented

Scale limits for VXLAN-ACI fabric groups

Scale limits are now available for VXLAN-ACI fabric groups.

For more information, see VXLAN-ACI fabric group scale limits .


Note


Unless explicitly called out, the listed scale numbers apply to all form factors.


This release supports the following cluster form factors:

  • Physical Appliance ( .iso ) – This form factor refers to the Cisco UCS physical appliance hardware with the Nexus Dashboard software stack pre-installed on it.

  • Virtual Appliance – The virtual form factor allows you to deploy a Nexus Dashboard cluster using VMware ESX ( .ova ) or RHEL KVM ( .qcow2 ).

    • Data node – This profile with higher system requirements is designed for higher scale and unified deployment.

    • App node – This profile with lower system requirements can be deployed as secondary nodes. If deployed as primary nodes, it does not support unified deployment.

    Support is also available for running a virtual Nexus Dashboard (vND) on the AWS public cloud and on Nutanix.

The values listed are explicitly tested and validated but may not represent the maximum theoretical system limits for Nexus Dashboard. For more information, see the corresponding tables for specific scalability information related to the functionality that you are using.

About supported node types and features

  • Several node types are available for Nexus Dashboard, including SE-NODE-G2 (UCS-C220-M5), ND-NODE-L4 (UCS-C225-M6), ND-NODE-G5S (UCS-C225-M8), and ND-NODE-G5L (UCS-C225-M8).

  • Key features that can be enabled per fabric include Controller , Telemetry , and Orchestration .

  • Node and feature compatibility is subject to guidelines and limitations, such as restrictions on mixing node types and enabling all features on certain clusters.

Supported Node Types and Feature Overview

These node types are available for Nexus Dashboard:

  • ND-NODE-G5L (UCS-C225-M8). The product ID of the 3-node cluster is ND-CLUSTERG5L.

  • ND-NODE-G5S (UCS-C225-M8). The product ID of the 3-node cluster is ND-CLUSTERG5S.

  • ND-NODE-L4 (UCS-C225-M6). The product ID of the 3-node cluster is ND-CLUSTER-L4.

  • SE-NODE-G2 (UCS-C220-M5). The product ID of the 3-node cluster is SE-CL-L3.


    Note


    Support for the SE-NODE-G2 (UCS-C220-M5) node will come to an end in an upcoming Nexus Dashboard release. The EOL milestones for this appliance can be found here:

    End-of-Sale and End-of-Life Announcement for the Cisco UCS M5 Rack Servers (C220 M5, C240 M5, C480 M5).

    Future Nexus Dashboard release notes will contain details about the last release where this appliance will be supported.


In addition, in LAN deployments, these are the available features that you can leverage:

  • Controller : Also referred to as Fabric Management. This feature is used to manage NX-OS and non-NX-OS switches (such as Catalyst, ASR, and so on). This includes creating any non-ACI fabric types, as well as performing software upgrades and creating new configurations on those fabrics.

  • Telemetry : This feature provides telemetry functionality, similar to the functionality provided by Nexus Dashboard Insights in prior releases. You can enable and use the Telemetry feature when you create or edit a fabric through Manage > Fabrics .

  • Orchestration : You can use the Orchestration feature through Nexus Dashboard to connect multiple ACI fabrics together, and consolidate and deploy tenants, along with network and policy configurations, across multiple ACI fabrics. You can enable and use the Orchestration feature when you add an ACI through Admin > System Settings > Multi-cluster connectivity > Connect Cluster.

For each fabric managed by Nexus Dashboard, you can enable the following features independently within the same Nexus Dashboard cluster or across a multi-cluster federated Nexus Dashboard deployment:

  • Controller

  • Telemetry

  • Orchestration


Note


Enabling all capabilities on a single cluster might not be available in some cluster deployment formats. For a quick reference of the supported form factors, scale, and cluster sizing requirements specific to your Nexus Dashboard deployment, see the Nexus Dashboard Capacity Planning tool.


Guidelines and limitations:

  • You cannot mix the newer ND-NODE-G5L or ND-NODE-G5S (UCS-C225-M8) nodes in a cluster with the older SE-NODE-G2 (UCS-C220-M5) and ND-NODE-L4 (UCS-C225-M6) nodes.

    In addition, you can only have homogeneous ND-NODE-G5L or ND-NODE-G5S clusters. In other words:

    • A cluster containing a ND-NODE-G5L node can only have additional ND-NODE-G5L nodes in that cluster, and

    • A cluster containing a ND-NODE-G5S node can only have additional ND-NODE-G5S nodes in that cluster.

  • The ND-NODE-G5L node is only supported for LAN deployments.

  • The virtual form factor does not support all features in many cluster sizes and types, as described in this document .

  • If a Nexus Dashboard node becomes unavailable, some Telemetry functionality may be impacted. Telemetry dynamic jobs such as Assurance, Bug Scan, and Log Collection, are blocked and will not run until the node is restored.

  • Telemetry functionality is fully supported during a node failure when the deployment is operating at 50% or less of the supported scale for its form factor. For example, a 3vND data form factor supports up to 100 switches at full scale. If a deployment contains 50 switches and a Nexus Dashboard node becomes unavailable, Telemetry services will continue to operate normally. For deployments operating above 50% of the supported scale, Telemetry behavior during a node failure is provided on a best-effort basis, and some functionality may be degraded.

Windows 11 VDI client sizing

In Windows 11 virtual desktop infrastructure (VDI) environments, allocate sufficient client resources to provide stable Nexus Dashboard UI performance when multiple users access the UI concurrently. The following configurations have been tested and validated for each concurrent VDI user session.

These sizing requirements apply to VDI client sessions used to access the Nexus Dashboard UI.

Component

Minimum supported configuration per user

Recommended configuration per user

CPU

8 vCPUs

16 vCPUs

Processor speed

2.1 GHz or higher

2.1 GHz or higher

Processor

Compatible 64-bit processor with two or more cores; Intel Xeon Silver 4116 or equivalent

Compatible 64-bit processor with two or more cores; Intel Xeon Silver 4116 or equivalent

Memory

8 GB RAM

32 GB RAM

Hardware acceleration

Enabled or disabled

Enabled

Display resolution

Higher than 1280 × 720 pixels

Higher than 1280 × 720 pixels

Scale for LAN Deployments

Form factors, cluster sizes, and general scale

This section provides information on form factors, cluster sizes, and general scale.

Form factors and cluster sizes for LAN deployments

The following tables contain supported switch scale based on the cluster form factor and size. For complete feature-specific scale, see the corresponding tables in this document.


Note


  • For supported form factors and cluster sizes for IPFM and SAN fabrics, see the later sections of this document.

  • If you are mixing NX-OS/IOS-XE and ACI fabrics in the same cluster, then the lesser of the two listed scale numbers applies.

  • Nexus Dashboard supports any number of fabrics as long as a minimum ratio of 1:10 for fabric to switches is maintained on the cluster.

  • The 5-node virtual cluster (app) is not supported as a greenfield deployment, and is only supported when upgrading existing clusters from Nexus Dashboard release 3.2.1 to Nexus Dashboard release 4.1.1 or Nexus Dashboard release 3.2.2 to Nexus Dashboard release 4.2.1 or 4.3.1. We recommend that you move the cluster to a supported form factor by taking a back up and restore. A 3-node virtual cluster (data) (Controller only) would be the equivalent for the 5-node virtual cluster (app) (Controller only).


Table 2. Form factors and cluster sizes for LAN deployments: 1-node physical clusters
Node type Enabled Features Supported NX-OS/IOS-XE scale Supported ACI Scale

SE-NODE-G2 and ND-NODE-L4

Controller only

50 switches (managed)

100 switches (monitored)

N/A

Controller and Telemetry

25 switches

Flow Telemetry: 500 flows/second

Traffic Analytics: 10,000 conversations/minute, 1 concurrent troubleshoot job

For full Telemetry scale, see Telemetry scale limits .

ND-NODE-G5S

Controller and Telemetry

50 switches

Flow Telemetry: 1,000 flows/second

Traffic Analytics: 10,000 conversations/minute, 1 concurrent troubleshoot job

For full Telemetry scale, see Telemetry scale limits .

Controller, Telemetry, and Orchestration

Note

 

For non-production use only

Table 3. Form factors and cluster sizes for LAN deployments: 3-node physical clusters
Node type Enabled Features Supported NX-OS/IOS-XE scale Supported ACI Scale

Notes

SE-NODE-G2 or ND-NODE-L4

Controller only

500 switches (managed)

1000 switches (monitored)

N/A

ND-NODE-L4

Telemetry only

400 switches

Flow Telemetry: 10,000 flows/second

Traffic Analytics: 100,000 conversations/minute, 5 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

Supports mixed ACI and NX-OS/IOS-XE deployment with 50/50 split

SE-NODE-G2

Controller and Telemetry or Telemetry only

250 switches

Flow Telemetry: 10,000 flows/second

Traffic Analytics: 100,000 conversation/minute, 5 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

Supports mixed ACI and NX-OS/IOS-XE deployment with 50/50 split

SE-NODE-G2 / ND-NODE-L4 1

Telemetry and Orchestration

N/A

  • SE-NODE-G2 :

    100 switches

    Flow Telemetry: 10,000 flows/second

    Traffic Analytics: 100,000 conversations/minute, 5 concurrent troubleshoot jobs

    Split supported is ACI (75) and NX-OS/IOS-XE (25) for IPN/ISN use case

  • ND-NODE-L4 :

    400 switches

    Flow Telemetry: 10,000 flows/second

    Traffic Analytics: 100,000 conversations/minute, 5 concurrent troubleshoot jobs

    Split supported is ACI (375) and NX-OS/IOS-XE (25) for IPN/ISN use case

For full Telemetry scale, see Telemetry scale limits .

NX-OS/IOS-XE switches supported only in External and inter-fabric connectivity fabric types

ND-NODE-L4

Controller, Telemetry, and Orchestration

250 switches

Flow Telemetry: 10,000 flows/second

Traffic Analytics: 100,000 conversations/minute, 5 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

For full Orchestration scale, see Orchestration scale limits .

ND-NODE-G5S

Controller, Telemetry, and Orchestration

500 switches

Flow Telemetry: 10,000 flows/second

Traffic Analytics: 100,000 conversations/minute, 5 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

For full Orchestration scale, see Orchestration scale limits .

ND-NODE-G5L

Controller, Telemetry, and Orchestration

1000 switches

Flow Telemetry: 10,000 flows/second

Traffic Analytics: 200,000 conversations/minute, 5 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

For full Orchestration scale, see Orchestration scale limits .

1 When mixing SE-NODE-G2 and ND-NODE-L4 nodes in the same cluster, the lower scale value applies.

As described in the following table, a 6-node physical cluster of SE-NODE-G2 (UCS-C220-M5) and ND-NODE-L4 (UCS-C225-M6) nodes is primarily designed for extended scale NX-OS/IOS-XE or ACI fabrics with the Telemetry feature enabled.

Table 4. Form factors and cluster sizes for LAN deployments: 6-node physical clusters
Node type Enabled Features Supported NX-OS/IOS-XE scale Supported ACI Scale

Notes

SE-NODE-G2 and ND-NODE-L4

Telemetry only

  • SE-NODE-G2 :

    500 switches

  • ND-NODE-L4 :

    750 switches

Flow Telemetry: 20,000 flows/second

Traffic Analytics: 200,000 conversations/minute, 8 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

  • SE-NODE-G2 :

    750 switches

  • ND-NODE-L4 :

    1000 switches

Flow Telemetry: 20,000 flows/second

Traffic Analytics: 200,000 conversations/minute, 8 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

For a mix of ACI and NX-OS/IOS-XE deployment with a 50/50 split, the scale will be 750 for a ND-NODE-L4-only cluster and 500 for a SE-NODE-G2-only cluster or a SE-NODE-G2/ND-NODE-L4 mixed cluster

SE-NODE-G2 and ND-NODE-L4

Telemetry and Orchestration 2

N/A

500 switches

Flow Telemetry: 20,000 flows/second

Traffic Analytics: 200,000 conversation/minute, 8 concurrent troubleshoot job

For full Telemetry scale, see Telemetry scale limits .

Split supported is ACI (450) and NX-OS/IOS-XE (50 for IPN/ISN)

ND-NODE-L4

Controller, Telemetry, and Orchestration

500 switches

Flow Telemetry: 20,000 flows/second

Traffic Analytics: 200,000 conversations/minute, 8 concurrent troubleshoot jobs

For full Telemetry scale, see Telemetry scale limits .

For full Orchestration scale, see Orchestration scale limits .

2

To enable Telemetry and Orchestration on a 6-node physical cluster, when the fabric is added through Onboard existing LAN fabric under Select a category , choose External and Inter-fabric connectivity in the Select a type step during the Create/Onboard Fabric workflow.

Table 5. Form factors and cluster sizes for LAN deployments: Virtual clusters
Node type Enabled Features Supported NX-OS/IOS-XE scale Supported ACI Scale

Virtual Clusters: 1-node virtual

App

ESXi / KVM

Controller only

50 switches (Managed)

100 switches (Monitored)

N/A

Data

ESXi / KVM

Controller and Telemetry

25 switches

Flow Telemetry: 500 flows/second

Traffic Analytics: 3000 conversation/minute, 1 concurrent troubleshoot job

For full Telemetry scale, see Telemetry scale limits .

Controller, Telemetry, and Orchestration

Note

 

For non-production use only

Data

Nutanix

Controller, Telemetry, and Orchestration

25 switches

Flow Telemetry: 500 flows/second

Traffic Analytics: 3000 conversation/minute, 1 concurrent troubleshoot job

For full Telemetry scale, see Telemetry scale limits .

Virtual Clusters: 3-node virtual

App

ESXi / KVM

Controller only

Managed: 100 switches

Monitored: 200 switches

N/A

App

ESXi only

Orchestration only

N/A

Same verified scalability as provided in Nexus Dashboard Orchestrator, release 4.2(3)

Data

ESXi / KVM

Controller only

Managed: 400 switches

Monitored: 1000 switches

N/A

Data

ESXi / KVM / Nutanix / AWS 3

Controller, Telemetry, and Orchestration

100 switches

Flow Telemetry: 2500 flows/second (not applicable for AWS)

Traffic Analytics: 5000 conversation/minute, 2 concurrent troubleshoot jobs

1 max online assurance job across all fabrics

For full Telemetry scale, see Telemetry scale limits .

Virtual Clusters: 6-node virtual

3 Data and 3 App nodes

ESXi

Note

 
Data nodes must be primary .

Controller, Telemetry, and Orchestration

200 switches

Flow Telemetry: 5000 flows/second

Traffic Analytics: 10,000 conversation/minute, 5 concurrent troubleshoot job

For full Telemetry scale, see Telemetry scale limits .

3

AWS deployments are supported only with out-of-band telemetry with Traffic Analytics

General scale limits

Table 6. General scale limits

Category

Verified Scale Limit

Standby nodes in a cluster

Up to 2 standby nodes.

  • Physical node clusters: Standby nodes are supported for most 3-node or larger clusters

  • Virtual node clusters: Standby nodes are supported only with a 3-node vND (app) profile for a Controller-only or Orchestration-only deployment.

Users configured on the cluster

1000

API requests rate

1000 requests in 6 seconds

Login domains

8

Clusters connected using multi-cluster connectivity

12

Fabrics across all clusters connected using multi-cluster connectivity

200

Switches across all clusters connected using multi-cluster connectivity

4000

Maximum latency between nodes for intra-cluster connectivity

50 ms

Maximum latency between cluster nodes and switches

150 ms

Maximum latency between nodes for inter-cluster connectivity

500 ms

Controller scale limits

This section provides verified scalability values for LAN fabrics.

Table 7. Fabric underlay and overlay scale limits

Category

Verified Scale Limit

Fabrics in a VXLAN EVPN fabric group

50

Switches per fabric

200

Physical interfaces

Note

 

Physical interfaces are for brownfield deployments.

11,500

Overlay scale for VRFs and networks

1000 VRFs, 3000 Layer 2 or Layer 3 networks

Supported scale for 1-node virtual Nexus Dashboard is 250 VRFs and 1000 networks.

Overlay associations

This category defines the number of networks per switch and attached to the interfaces.

The supported total number of networks x switches x interfaces associations are 5 million per cluster, where:

  • You have 3000 or fewer networks, and

  • You have 200 or fewer switches

For example:

  • Supported : 3000 networks x 100 switches x 10 interfaces = 3 million (supported because this total is less than 5 million)

  • Not supported : 3000 networks x 200 switches x 10 interfaces = 6 million (unsupported because this total exceeds 5 million)

VRF instances for external connectivity

1000

IPAM integrator application

150 networks with a total of 4k IP allocations on the Infoblox server

ToR devices

40 leaf switches with 320 ToR switches

A Data Center VXLAN EVPN fabric can manage both Layer 2 ToR switches and leaf switches.

32 ToR switches (or 16 vPC-ToR pairs) can be connected per leaf-vPC pair.

Table 8. Endpoint locator scale limits

Description

Verified Limit

Endpoints

100,000

Note

 

For a single-node virtual cluster, the scale is reduced to 1 instance of an endpoint locator with 10,000 endpoints.

Dual-home and dual-stacked (IPv4 + IPv6) endpoints

60,000

BGP route reflectors or route servers

2 per fabric

Fabrics in VXLAN EVPN fabric group

50

Note

 

This number cannot be larger than the number of fabrics across all clusters in a VXLAN EVPN multi-cluster fabric group.

Table 9. Virtual Machine Manager (VMM) scale limits

Description

Verified Limit

VMware Center Servers

4

Note

 

For 1-node virtual Nexus Dashboard clusters, the scale is reduced to 1 VMware Center Server.

vCenter endpoints (VMs)

1-node physical cluster: 100

3-node physical cluster: 4000

6-node physical cluster: 4000

1-node virtual cluster: 100

3-node virtual cluster: 1000

6-node virtual cluster: 1000

Kubernetes clusters

4

Kubernetes Visualizer application

160 namespaces with up to 1002 pods

Table 10. Security groups scale limits

Description

Verified Limit

VXLAN security groups and selectors

4000 selectors (if 1 per security group then 4000 security groups)

12,000 bidirectional security associations

Adjust the number of security associations if the number of class maps per policy map is more than 1, so that the maximum total number of security associations is always 12,000 bidirectional when deployed on the devices.

1 class map + 1 policy map per association

Associations in a startup configuration

Note

 

Nexus Dashboard does not support a bootflash repartition.

12,000

VXLAN-ACI fabric group scale limits

A VXLAN-ACI fabric group is a group that includes a Cisco ACI fabric connected to one or more Cisco NX-OS fabrics. This type integrates Cisco NX-OS and Cisco ACI fabrics for unified management and policy deployment.

The VXLAN-ACI fabric group is an implementation of the Nexus One architecture, which is used to unify the management and operation of Cisco Application Centric Infrastructure (ACI) and Cisco NX-OS Virtual Extensible LAN (VXLAN) Ethernet VPN (EVPN) fabrics. This architecture provides consistent policy enforcement and operational workflows across domains using a single management plane: Nexus Dashboard. For more information, see Understanding the Nexus One architecture.

Table 11. Scale limits for VXLAN-ACI fabric groups

Category

Verified Scale Limit

Tenants

100

Tenants in a tenant domain

10

Stretched VRF

200

Stretched network

400 (2 per VRF)

Security groups

400

Security contracts

500

Security associations

500

Network attachments

2000

Protocol definitions

100

Protocol definitions per contract

5

Selectors for security groups: 1000 total:

Network selectors

400

Connected endpoint selectors

200

External subnet selectors

400

IPFM fabric scale limits

  • IPFM fabric scale limits define the maximum number of supported switches, flows, endpoints, and policies for different deployment types and operational modes.

  • Scale limits vary based on physical or virtual Nexus Dashboard deployments and the mode of operation (Active, Passive, Mixed).

  • These values are verified and ensure optimal performance and reliability within supported configurations.

Scale limits for IPFM fabrics by deployment type and mode

The following tables provide the verified scale limits for IPFM fabrics based on deployment type and operational mode.

Table 12. Scale limits for IPFM fabrics based on deployment type

Deployment Type

Verified Scale Limit

1-node physical Nexus Dashboard

35 switches (2 spine switches and 33 leaf switches)

3-node physical Nexus Dashboard

120 switches (2 spine switches, 100 leaf switches, and 18 tier-2 leaf switches) - IPFM Fabric

60 switches - LAN Fabric

50 switches - VxLAN Fabric

1-node virtual Nexus Dashboard (app node)

35 switches (2 spine switches and 33 leaf switches)

3-node virtual Nexus Dashboard (app node)

120 switches (2 spine switches, 100 leaf switches, and 18 tier-2 leaf switches) - IPFM Fabric

60 switches - LAN Fabric

50 switches - VxLAN Fabric

Table 13. Scale limits for IPFM fabrics based on the type of mode

Category

Verified Scale Limit

NBM Active Mode Only

NBM Passive Mode Only

Mixed Mode

NBM Active VRF

NBM Passive VRF

Number of switches

120

32

32

32

Number of flows

32,000

32,000

32,000

32,000

Number of endpoints (discovered hosts)

5000

1500

3500

1500

VRFs

16

16

16

16

Host Policy - Sender

8000

NA

8000

NA

Host Policy - Receiver

8000

NA

8000

NA

Host Policy - PIM (Remote)

512

NA

512

NA

Flow Policy

2500

NA

2500

NA

NBM ASM group range

20

NA

20

NA

Host Alias

2500

NA

2500

NA

Flow Alias

2500

NA

2500

NA

NAT Flows

3000

3000

3000

3000

RTP Flow Monitoring

8000

8000

8000

8000

PTP Monitoring

120 switches

32 switches

32 switches

32 switches

Telemetry scale limits

  • Telemetry scale limits define the maximum supported values for various Telemetry features in Nexus Dashboard.

  • These limits include endpoints, flow telemetry rules, exporters, and integrations for both physical and virtual clusters.

  • Values are verified and may differ based on cluster size, node type, and feature.

Telemetry scale limits reference

Table 14. Telemetry scale limits

Description

Verified Limit

Endpoints

1-node physical cluster: 20,000

3-node physical cluster:

  • ND-NODE-G5L: 240,000

  • All other node types: 180,000

6-node physical cluster: 240,000

1-node virtual cluster: 20,000

3-node virtual clusters: 180,000

6-node virtual clusters: 180,000

Flow telemetry rules

500 rules per switch for both NX-OS and ACI fabrics.

Exporters for Kafka

20 exporters for Alerts and Events without the Statistics enabled

6 out of the 20 exporters can have Statistics enabled for Alerts and Events

6 exporters for Usage for ACI fabrics only

6 email exporters

20 syslog exporters

Export data

5 emails per day for periodic job configurations.

Syslog

5 syslog exporter configurations across fabrics.

Webhook

10 webhook exporters, supported only for fabric anomalies and advisories

AppDynamics

5 apps

50 tiers

250 nodes

300 net links

1000 flow groups

DNS integration

40,000 DNS entries for physical clusters.

10,000 DNS entries for virtual clusters.

Panduit power distribution unit (PDU) integration

1000 per Nexus Dashboard cluster

500 per fabric

Orchestration scale limits

This section provides verified scalability values for Orchestration.

Table 15. General scale limits

Category

Verified Scale Limit

Fabrics

Up to 100 fabrics total on-boarded in Nexus Dashboard .

Up to 14 of those fabrics can be enabled with EVPN sessions between them.

For specific details about template object scale, which depends on the type of the templates you deploy (Multi-Fabric vs Autonomous), see the tables below.

Pods per fabric

12 or 25, depending on the Cisco APIC release managing the site.

For more information, see the Cisco APIC Verified Scalability Guide for your release.

Leaf switches per fabric

400 in a single pod

500 across all pods in multi-pod ACI fabrics

The number of leaf switches supported within each fabric depends on the Cisco APIC release managing that fabric. For more information, see the Cisco APIC Verified Scalability Guide for your release.

Total leaf switches across all fabrics

(max number of fabrics) * (max number of leaf switches per fabric) , for example:
  • For multi-fabric deployments, if every fabric is deployed as a multi-pod ACI fabric, then the maximum number of leaf switches is (14 fabrics) * (500 switches) = 7000 .

  • For Autonomous templates, if Orchestrator is deployed in a physical Nexus Dashboard cluster, then the maximum number of leaf switches is (100 fabrics) * (500 switches) = 50,000

  • For Autonomous templates, if Orchestrator is deployed in a virtual Nexus Dashboard cluster, then the maximum number of leaf switches is (20 fabrics) * (500 switches) = 10,000

Note that specific objects' scale (such as VRFs, BDs, EPGs, and so on) still applies, as described in the template-specific sections below.

Endpoints per fabric

The Orchestrator endpoint scale for each fabric is the same as the scale supported by the fabric's APIC.

Note

 

If the fabric is part of a VXLAN fabric group, the total number of endpoints is the sum of local and remote endpoints.

Templates Scale Limits


Note


If a specific object's scale (such as contracts, filters, or VRFs) is not included in the following table, that object does not have a unique scale limit and the general "Policy Objects per Schema" and "Policy Objects per Template" limits apply. If any such objects were explicitly listed in previous releases, those limitations have been lifted and removed from the list.


Table 16. Application templates scale limits

Category

Verified Scale Limit

Schemas

1000

Templates per schema

30

Service graphs per schema

500

Service graph nodes per service graph

5 for Autonomous templates

2 for multi-fabric templates

Policy objects per schema

2000

Policy objects per template

2000

Contract preferred group (BD/EPG combinations)

5000

PBR destinations per fabric (including all local and remote*)

*Note that if you configure some of the new PBR use cases, such as vzAny with PBR or L3Out-to-L3Out with PBR, you may be required to implement hair-pinning of traffic across fabrics to ensure traffic can be always steered using both devices and deployed in the source and destination fabrics. As a result, the leaf nodes in a given fabric must be programmed with PBR information about the device(s) in remote fabrics as well, and those remote PBR nodes are counted toward the maximum number listed here.

1500

Table 17. Fabric resource policies scale

Category

Verified Scale Limit

Policy objects per template

2000

Table 18. Tenant policies, fabric policies, and monitoring policies templates scale

Category

Verified Scale Limit

Policy objects per template

500

Monitoring Policy Scale

ERSPAN sessions

20 per fabric

Fabric SPAN sessions

30 per fabric

Table 19. L3Out templates scale

Category

Verified Scale Limit

IP L3Outs per template

100

SR-MPLS L3Outs per template

100

All other objects' scale

The scale for other L3Out template objects that are not explicitly listed in this table is the same as the scale supported by the fabric's APIC. For detailed information, see the Cisco APIC Verified Scalability Guide for the APIC release version managing each fabric.

Orchestrator-deployed objects scale

To better understand the scalability values captured in the following table for traditional multi-fabric deployments, it is important to clarify that there are three kinds of Orchestrator-deployed objects:

  • Fabric local objects—these are the objects defined in templates associated to a single fabric, which get deployed by Orchestrator only in that specific fabric.

  • Shadow objects—these are the objects deployed by Orchestrator in a fabric as a result of a contract established between fabric local and remote objects, they are the representation ("shadow)" of the remote object in the local fabric.

  • Stretched objects—these are the objects defined in templates that are associated with multiple fabrics, which get deployed by Orchestrator concurrently on all those fabrics.

The table below captures the maximum number of objects that Orchestrator can deploy in a given fabric and includes the sum of all three kinds of objects described above.

For example, if you have two fabrics and you define three templates on Orchestrator— template-1 associated to fabric-1 , template-2 associated to fabric-2 , and template-stretched associated to both fabric-1 and fabric-2 —then:

  • If you configure and deploy EPG-1 in template-1 , this will count as one EPG towards maximum allowed for fabric-1 .

  • If you configure and deploy EPG-2 in template-2 , this will count as one EPG towards maximum allowed for fabric-2 .

  • If you apply a contract between EPG-1 and EPG-2 or add both EPGs to the Preferred Group), a shadow EPG-2 will be created in fabric-1 and a shadow EPG-1 in fabric-2 . As a result, two EPGs will now be counted towards the maximum allowed in each fabric.

  • Finally, if you configure and deploy EPG-3 in template-stretched , it will count as another EPG in each fabric, bringing the total to 3 EPGs towards the maximum allowed scale.

It is worth adding that the maximum number of objects supported in a given fabric (and captured in the Verified Scalability Guide for Cisco APIC) must not exceed the sum of objects locally defined on APIC plus the objects pushed from Orchestrator to that fabric (Orchestrator-deployed objects).


Note


For maximum scale Nexus Dashboard Orchestrator configurations with many features enabled simultaneously, we recommend that those configurations be tested in a lab before deployment.


Table 20. Orchestrator-deployed logical objects scale for multi-fabric templates

Category

Maximum number of objects per fabric for up to 4 fabrics

Maximum number of objects per fabric for 5-14 fabrics

Tenants

1000

400

VRFs

2000

1000

BDs

6000

4000

Contracts

6000

4000

EPGs

6000

4000

ESGs

5000

4000

Isolated EPGs

500

500

Microsegment EPGs

2000

500

L3Out external EPGs

500

500

Subnets

8000

8000

L4-L7 logical devices

400

400

Graph instances

250

250

Device clusters per tenant

10

10

Number of graph instances per device cluster

125

125

Nexus Dashboard Orchestrator provides support for autonomous sites. When creating application templates, you can now choose to designate the template as Autonomous. This allows you to associate the template to one or more fabrics that are operated independently and are not connected through an Inter-Site Network (no intersite VXLAN communication).

Because autonomous sites are by definition isolated and do not have any intersite connectivity, there is no shadow object configuration across fabrics and no cross-programming of pctags or VNIDs in the spine switches for intersite traffic flow.

The autonomous templates allow for significantly higher deployment scale as shown in the following table. Since there are no stretched objects or shadow objects, the scale values shown in the table below reflect the specific fabric-local objects that Orchestrator deploys in each fabric.

Table 21. Orchestrator-deployed objects scale for autonomous templates

Category

Verified Scale Limit (per fabric)

Tenants

1000

VRFs

2000

BDs

6000

Contracts

6000

EPGs

6000

ESGs

5000

Isolated EPGs

500

Microsegment EPGs

2000

L3Out external EPGs

500

Subnets

8000

Number of L4-L7 logical devices

400

Number of graph instances

250

Number of device clusters per tenant

10

Number of graph instances per device cluster

125

VRF/BD VNID translation scale

Table 22. VRF/BD VNID translation scale

Category

Verified Scale Limit

Fixed spines

21,000

Modular spines

42,000

Scale for SAN Deployments

SAN scale limits

  • SAN scale limits define the maximum number of fabrics, switches, and ports that can be managed by Nexus Dashboard, depending on the deployment type and cluster size.

  • These limits are verified values based on specific deployment profiles and may differ from theoretical maximums.

  • The maximum number of SAN switches and fabrics is determined by the number of nodes in the cluster.

Scale limits for SAN deployments

For SAN deployments, you can set the maximum number of SAN switches and fabrics that can be managed by Nexus Dashboard by navigating to Admin > System Settings > Fabric management > Discovery and entering the necessary value in the Maximum number of fabrics managed field. The maximum number of SAN switches and fabrics that can be managed by Nexus Dashboard depends on the number of nodes in your cluster:

  • For 1-node clusters, 24 is the default maximum number of SAN fabrics that can be managed by Nexus Dashboard. This value can be increased up to 160 . However, the number of switches across all fabrics are within the supported verified scale of 80 switches.

  • For 3-node clusters, 24 is the default maximum number of SAN fabrics that can be managed by Nexus Dashboard. This value can be increased up to 160 . However, the number of switches across all fabrics are within the supported verified scale of 160 switches.

Table 23. Scale limits for SAN deployments

Deployment Type

Verified Limit

Without SAN Insights

With SAN Insights

1-node virtual Nexus Dashboard (App node) 1

80 switches, 20k ports

40 switches, 10k ports, and 40k ITs

1-node virtual Nexus Dashboard (Data node)

80 switches, 20k ports

80 switches, 20k ports, and 1M ITLs/ITNs 2

1-node physical Nexus Dashboard (SE)

80 switches, 20k ports

80 switches, 20k ports, and 120k ITLs/ITNs

3-node virtual Nexus Dashboard (App node)

160 switches, 40k ports

80 switches, 20k ports, and 100k ITs

3-node virtual Nexus Dashboard (Data node)

160 switches, 40k ports

160 switches, 40k ports, and 240k ITLs/ITNs

3-node physical Nexus Dashboard

160 switches, 40k ports

160 switches, 40k ports, and 500k ITLs/ITNs

1 Application nodes have fewer features than data nodes. For example, the lun and fc-scsi.scsi_initiator_itl_flow features are not supported in the app ova, whereas those features are supported in the data ova. Therefore, you would have to install the data ova in order to use the lun or fc-scsi.scsi_initiator_itl_flow features.

2 1 million flows is the maximum number supported. If other features are enabled that consume resources, 1 million flows will not be stable in all situations. Nexus Dashboard consumes more resources per flow when processing telemetry from a larger number of devices. Watch flow counts and node memory usage (1 minute averages above ~105GB starts to show instability).


Note


ITLs - Initiator-Target-LUNs

ITNs - Initiator-Target-Namespace ID

ITs - Initiator-Targets


Table 24. Scale limits for SAN zones

Description

Verified Limits

Zone sets

1000

Zone

16,000