Switch Specifications
The following table lists the environmental specifications for the Cisco MDS 9220i switch:
|
Description |
Specification |
|---|---|
|
Temperature, ambient operating |
32 to 104°F (0 to 40°C) |
|
Temperature, ambient nonoperating and storage |
-40 to 158°F (-40 to 70°C) |
|
Humidity (RH), ambient (noncondensing) operating |
10 to 90% |
|
Humidity (RH), ambient (noncondensing) nonoperating and storage |
10 to 95% |
|
Altitude, operating |
-197 to 6500 ft (-60 to 2000 m) |
The following table lists the physical specifications for the Cisco MDS 9220i switch.
|
Description |
Specification |
|---|---|
|
Dimensions (HxWxD) |
1.72 x 17.3 x 20.11 in. (4.36 x 43.94 x 51.07 cm) excluding PSU, fan module handles, and USB stick |
|
Rack Space |
Chassis requires 1 RU (1.75 in. or 4.45 cm) |
|
Weight |
21.61 lb (9.8 kg) including two PSUs and four fans, but excluding optical modules |
|
Airflow |
We recommend that you maintain a minimum air space of 2.5 in. (6.4 cm) between walls and chassis air vents and a minimum horizontal separation of 6 in. (15.2 cm) between two chassis to prevent overheating. |