The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
|
|
DefensePro X10/X20 |
DefensePro X40 |
DefensePro X50/X50HP |
DefensePro X80 |
| Programmable Mitigation Performance |
||||
| On-Demand Scalable Clean Throughput Licenses |
DefensePro |
DefensePro |
DefensePro |
DefensePro |
| DefensePro |
DefensePro |
DefensePro |
DefensePro |
|
| DefensePro |
DefensePro |
DefensePro |
DefensePro |
|
| DefensePro |
|
DefensePro |
|
|
| DefensePro |
|
DefensePro |
|
|
| DefensePro |
|
DefensePro |
|
|
| Max Programmable Mitigation Throughput |
10 Gbps/20 Gbps |
40 Gbps |
50 Gbps |
80 Gbps |
| Max Attack Concurrent Sessions |
Unlimited |
|
|
|
|
|
DefensePro X90/X90HP |
DefensePro X100/X200 |
DefensePro X110/X220/X380 |
DefensePro X400/X800 |
| Programmable Mitigation Performance |
||||
| On-Demand Scalable Clean Throughput Licenses |
DefensePro |
DefensePro |
DefensePro |
DefensePro |
| DefensePro |
DefensePro |
DefensePro |
DefensePro |
|
| DefensePro |
DefensePro |
DefensePro |
|
|
| DefensePro |
|
|
|
|
| DefensePro |
|
|
|
|
| DefensePro |
|
|
|
|
| Max Programmable Mitigation Throughput |
90 Gbps |
100 Gbps/200 Gbps |
110 Gbps/220 Gbps/380 Gbps |
400 Gbps/800 Gbps |
| Max Attack Concurrent Sessions |
Unlimited |
|
|
|
|
|
DefensePro X10/X20 |
DefensePro X40 |
DefensePro X50/X50HP |
DefensePro X80 |
| Programmable Mitigation Performance |
||||
| Distributed Denial of Service (DDoS) Flood Attack Prevention Rate |
14 Mpps |
35 Mpps |
45 Mpps/200 Mpps |
35 Mpps |
| Latency |
<60 microseconds |
|||
| Real-Time Signatures |
Detect attacks and protect in less than 10 seconds |
|||
| SSL/TLS Decryption |
||||
| SSL/Transport Layer Security (TLS) Connections per Second |
43 KCPS (RSA 2K) |
95 KCPS (RSA 2K) |
100 KCPS (RSA 2K) |
95 KCPS (RSA 2K) |
| TLS 1.3 Perfect Forward Secrecy (PFS) HW Acceleration Support |
Yes |
Yes |
Yes |
Yes |
|
|
DefensePro X90/X90HP |
DefensePro X100/X200 |
DefensePro X110/X220/X380 |
DefensePro X400/X800 |
| Programmable Mitigation Performance |
||||
| Distributed Denial of Service (DDoS) Flood Attack Prevention Rate |
45 Mpps/200 Mpps |
142 Mpps |
530 Mpps |
1,119 Mpps |
| Latency |
<60 microseconds |
|||
| Real-Time Signatures |
Detect attacks and protect in less than 10 seconds |
|||
| SSL/TLS Decryption |
||||
| SSL/Transport Layer Security (TLS) Connections per Second |
100 KCPS (RSA 2K) |
150 KCPS (RSA 2K) |
110 KCPS (RSA 2K) |
200 KCPS (RSA 2K) |
| TLS 1.3 Perfect Forward Secrecy (PFS) HW Acceleration Support |
Yes |
Yes |
Yes |
Yes |
|
|
DefensePro X10/X20 |
DefensePro X40 |
DefensePro X50/X50HP |
DefensePro X80 |
| Blocking Performance |
||||
| Maximal DDoS Blocking Throughput |
- |
- |
- |
- |
| Maximal DDoS Blocking (Packets per Second [PPS]) |
- |
- |
- |
- |
| Inspection Ports |
||||
| 10/100/1000 Copper Ethernet |
Up to 16 (2x8) – Modular |
- |
- |
- |
| 1 GE/10 GE |
- |
12 Small Form-Factor Pluggable Plus (SFP+) |
- |
12 (SFP+) |
| 10 GE/25 GE |
Up to 8 (2x4) (SFP+) |
- |
Up to 24 (8x3) (SFP+) |
- |
| 40 GE |
- |
6 Quad SFP+ (QSFP+) |
Up to 6 (2x3) (QSFP+) |
6 (QSFP+) |
| 100 GE |
- |
- |
- |
- |
| 400 GE1 |
- |
- |
- |
- |
|
|
DefensePro X90/X90HP |
DefensePro X100/X200 |
DefensePro X110/X220/X380 |
DefensePro X400/X800 |
| Blocking Performance |
||||
| Maximal DDoS Blocking Throughput |
- |
800 Gbps |
800 Gbps |
3.4 Tbps |
| Maximal DDoS Blocking (Packets per Second [PPS]) |
- |
1.19 Billion |
1.19 Billion |
2.7 Billion |
| Inspection Ports |
||||
| 10/100/1000 Copper Ethernet |
- |
- |
- |
- |
| 1 GE/10 GE |
- |
- |
- |
- |
| 10 GE/25 GE |
Up to 24 (8x3) (SFP+) |
24 (SFP+/SFP28) |
24 (SFP+/SFP28) |
- |
| 40 GE |
Up to 6 (2x3) (QSFP+) |
8 (QSFP+/QSFP28) |
8 (QSFP+/QSFP28) |
- |
| 100 GE |
- |
- |
- |
18 (QSFP28) |
| 400 GE1 |
- |
- |
- |
4 (QSFP-DD) |
|
|
DefensePro X10/X20 |
DefensePro X40 |
DefensePro X50/X50HP |
DefensePro X80 |
| Management Ports |
||||
| 10/100/1000 Copper Ethernet |
2 |
|||
| Management Console |
RJ-45 |
|||
| Operation Mode |
||||
| Network Operation |
Transparent L2 Forwarding, IP Forwarding |
|||
| Deployment Modes |
Inline, SPAN port monitoring, Copy port monitoring, Out-of-path mitigation (scrubbing center solution) |
|||
| Tunneling Protocols |
VLAN Tagging, Layer 2 Tunneling Protocol (L2TP), Multiprotocol Label Switching (MPLS), Generic Routing Encapsulation (GRE), General Packet Radio Service Tunneling Protocol (GTP), IPinIP |
|||
| IPv6 |
Yes |
|||
| Jumbo Frame |
- |
Supported |
||
| Block Actions |
Drop packet, reset (source, destination, both), suspend (source IP address, source port, destination IP address, destination port or any combination), challenge-response for TCP, HTTP and DNS suspicious traffic |
|||
|
|
DefensePro X90/X90HP |
DefensePro X100/X200 |
DefensePro X110/X220/X380 |
DefensePro X400/X800 |
| Management Ports |
||||
| 10/100/1000 Copper Ethernet |
2 |
|||
| Management Console |
RJ-45 |
|||
| Operation Mode |
||||
| Network Operation |
Transparent L2 Forwarding, IP Forwarding |
|||
| Deployment Modes |
Inline, SPAN port monitoring, Copy port monitoring, Out-of-path mitigation (scrubbing center solution) |
|||
| Tunneling Protocols |
VLAN Tagging, Layer 2 Tunneling Protocol (L2TP), Multiprotocol Label Switching (MPLS), Generic Routing Encapsulation (GRE), General Packet Radio Service Tunneling Protocol (GTP), IPinIP |
|||
| IPv6 |
Yes |
|||
| Jumbo Frame |
- |
Supported |
||
| Block Actions |
Drop packet, reset (source, destination, both), suspend (source IP address, source port, destination IP address, destination port or any combination), challenge-response for TCP, HTTP and DNS suspicious traffic |
|||
|
|
DefensePro X10/X20 |
DefensePro X40 |
DefensePro X50/X50HP |
DefensePro X80 |
| High Availability |
||||
| Fail-open/ |
Internal fail-open/ |
Internal fail-close for optical transceivers (i.e., SFP+, QSFP+) |
Internal fail-open/ |
Internal fail-close for optical transceivers |
| Dual Power Supply |
Yes, hot swappable |
|||
| Physical |
||||
| Dimensions |
436 x 406 x 44 mm (1U) |
438 x 530 x 88 mm (2U) EIA rack or standalone: 530 mm (20.86 in) |
490 x 406 x 44 mm (1U) |
438 x 530 x 88 mm (2U) EIA rack or standalone: 530 mm (20.86 in) |
| Weight |
Single power supply: 6 kg |
Single power supply: |
Single power supply: 7 kg |
Single power supply: 11 kg (24.2 lbs.) Dual power supply: 12 kg (26.4 lbs.) |
| Power Supply (Auto-range) |
80 plus certified AC: |
80 plus certified AC: |
80 plus certified AC: |
80 plus certified AC: |
| Power Consumption |
Single and dual power supply: 140W |
Dual power supply: 400W |
Single and dual power supply: 350W |
Dual power supply: 400W |
| Heat Dissipation |
Single and dual power supply: 480 BTU/h |
Dual power supply: 1,364 BTU/h |
Single and dual power supply: 640 BTU/h |
Dual power supply: 1,364 BTU/h |
| Operating Temperature |
0°–40°C (32°–104°F) |
|||
| Humidity |
5% to 95% non-condensing |
|||
|
|
DefensePro X90/X90HP |
DefensePro X100/X200 |
DefensePro X110/X220/X380 |
DefensePro X400/X800 |
| High Availability |
||||
| Fail-open/ |
Internal fail-open/failclose for modular copper ports; Internal fail-open/fail-close for fiber ports or opticaltransceivers (i.e., SFP+) |
Internal fail-close for optical transceivers (e.g., SFP+, SFP28, QSFP+, QSFP28) |
Internal fail-close for optical transceivers (e.g., QSFP28, QSFP-DD) |
|
| Dual Power Supply |
Yes, hot swappable |
|||
| Physical |
||||
| Dimensions |
490 x 406 x 44 mm (1U) |
482 x 550 x 87 mm (2U) EIA rack or standalone: 482 mm (19 in) |
482 x 550 x 87 mm (2U) EIA rack or standalone: 482 mm (19 in) |
424 x 600 x 88 mm (2U) EIA rack or standalone: 482 mm (19 in) |
| Weight |
Single power supply: 7 kg (15.4 lbs.) Dual power supply: 7.5 kg (16.5 lbs.) |
Dual power supply: 14.5 Kg (31.9 lbs) |
Dual power supply: |
Dual power supply: 27.5 kg (60.6 lbs.) |
| Power Supply (Auto-range) |
80 plus certified AC: |
80 plus certified AC: |
80 plus certified AC: |
80 plus certified AC: |
| Power Consumption |
Single and dual power supply: 350W |
Dual power supply: 550W |
Dual power supply: 550W |
Dual power supply: 970W |
| Heat Dissipation |
Single and dual power supply: 640 BTU/h |
Dual power supply: 1880 BTU/h |
Dual power supply: 1880 BTU/h |
Dual power supply: 3,300 BTU/h |
| Operating Temperature |
0°–40°C (32°–104°F) |
|||
| Humidity |
5% to 95% non-condensing |
|||
External fiber fail-open switch is available at additional cost.
|
|
DefensePro X10/X20 |
DefensePro X40 |
DefensePro X50/X50HP |
DefensePro X80 |
| Compliance & Certifications |
||||
| Restriction of Hazardous Substances (RoHS) |
Compliant (EU directive 2011/65/EU, 2015/863/EU) |
|||
| Export Control Classification Number (ECCN) |
5A002.a.2 |
|||
| Safety/ Electromagnetic Compatibility (EMC)/EMI & Certifications |
UL/TUV, FCC (USA), IC (Canada), CE (Europe), UKCA (UK), RCM (Australia/NZ), VCCI (Japan), KCC (Korea), EAC (Russia), BSMI (Taiwan), Anatel (Brazil), NOM (Mexico). For more information visit: https://www.radware.com/newsroom/certifications-hardware/ |
|||
| Warranty |
1-year hardware and software maintenance |
|||
| Support |
Certainty Support Program |
|||
|
|
DefensePro X90/X90HP |
DefensePro X100/X200 |
DefensePro X110/X220/X380 |
DefensePro X400/X800 |
| Compliance & Certifications |
||||
| Restriction of Hazardous Substances (RoHS) |
Compliant (EU directive 2011/65/EU, 2015/863/EU) |
|||
| Export Control Classification Number (ECCN) |
5A002.a.2 |
|||
| Safety/ Electromagnetic Compatibility (EMC)/EMI & Certifications |
UL/TUV, FCC (USA), IC (Canada), CE (Europe), UKCA (UK), RCM (Australia/NZ), VCCI (Japan), KCC (Korea), EAC (Russia), BSMI (Taiwan), Anatel (Brazil), NOM (Mexico). For more information visit: https://www.radware.com/newsroom/certifications-hardware/ |
|||
| Warranty |
1-year hardware and software maintenance |
|||
| Support |
Certainty Support Program |
|||
1 Requires 400G connectivity, available at additional cost.
2 External fiber fail-open switch is available at additional cost.
DefensePro XVA for Private Clouds
| Hypervisor |
Kernel Virtual Machine (KVM) kernel 3.19, QEMU 2.0, VMware (ESX server versions: 6.0, 6.5, 6.7), OpenStack 16.1 |
| Minimum VM requirements |
2 vCPUs, 21GB RAM, 10GB storage |
| Performance1 |
|
| On-Demand Scalable Throughput Licenses |
DefensePro VA 200 Mbps, 500 Mbps, 1 Gbps, 2 Gbps, 5 Gbps, 10 Gbps, 20 Gbps(2), 40 Gbps, 100 Gbps |
| Max Mitigation Capacity/Throughput |
Up to 100 Gbps per DefensePro VA instance |
| Max Legit Concurrent Sessions |
1,000,000 sessions per vCPU |
| Max Attack Concurrent Sessions |
Unlimited |
| Max DDoS Flood Attack Prevention Rate |
Up to 950,000 pps per vCPU |
| Latency |
<60 microseconds |
| Real-Time Signatures |
Detect attacks and protect in less than 18 seconds |
| Inspection ports |
|
| 10 GE, 25 GE, 40 GE, 100 GE |
2 (Intel® Ethernet Server Adapter X520, 10 GE; Intel® Ethernet Controller XL710, 40 GE), PCI Passthrough 4 (Intel® Ethernet Network Adapter XXV710, 10 GE, 25 GE), SRIOV 2 (Intel® Ethernet Network Controller E810 10GE, 25GE, 50GE, 100GE), Single Root I/O Virtualization (SRIOV) |
| Management Ports |
|
| Ethernet |
Via virtual interface (virtio) |
| Management Console |
KVM Virsh; VMware Serial Port |
| Operation Mode |
|
| Network Operation |
Transparent L2 Forwarding/IP Forwarding |
| Deployment Modes |
In-line |
| Tunneling Protocols |
VLAN Tagging, L2TP, MPLS, GRE, GTP, IPinIP |
| IPv6 |
Yes |
| Jumbo Frame |
Up to 2KB |
| Block Actions |
Drop packet, reset (source, destination, both), suspend (source IP address, source port, destination IP address, destination port or any combination), challenge-response for TCP, HTTP, and DNS suspicious traffic |
| Support |
|
| Support |
Certainty Support Program |
1 Performance figures assume Intel® server-grade processor with 3 GHz.
2 20 Gbps, 40 Gbps, 100Gbps Throughput License supported on KVM.
DefensePro XVA for Public Clouds
| Native Public Cloud support |
Amazon Web Services (AWS), Azure |
| Minimum VM requirements |
2 vCPUs, 21GB RAM, 10GB storage |
| Performance |
|
| Max Mitigation Capacity/Throughput |
Up to 25 Gbps per DefensePro VA instance |
| Max Legit Concurrent Sessions |
1,000,000 sessions per vCPU |
| Max Attack Concurrent Sessions |
Unlimited |
| Max DDoS Flood Attack Prevention Rate |
Up to 500,000 pps per vCPU |
| Inspection Ports |
|
| Ethernet |
1 or 2 inspection ports for typical deployments. Additional inspection ports up to a limit supported by the instance type |
| Management Ports |
|
| Ethernet |
2 ports |
| Operation Mode |
|
| Network Operation |
AWS: Symmetric inspection, IP Forwarding Mode Azure: Asymmetric inspection, Destination NAT Forwarding Mode |
| Deployment Modes |
AWS: In-VPC or Security VPC Azure: In-VPC |
| High Availability |
|
| Active: Active |
AWS and Azure: Integration with AWS Gateway Load Balancer and Azure Load Balancer |
| Fail-open/fail-close |
AWS: With Radware-provided Lambda function |
| Support |
Certainty Support Program |
DefensePro is a registered trademark of Radware, Inc.
DefensePro X and other industry-leading DDoS protection solutions are sold by Cisco through its global OEM partnership with Radware.