Contents
First Published:
Last Updated:
Text Part Number:
UCS M5 Server BIOS Tokens
New and Changed Information
This section provides information about new and changed M5 server BIOS tokens in Cisco UCS Manager, Release 3.2.
M5 Server BIOS Tokens in Release 3.2(3)
Cisco UCS Manager, Release 3.2(3) introduces S3260 M5 to the list of supported M5 platforms. The M5 platforms supported in this release are:
B200 M5
B480 M5
C220 M5
C240 M5
C480 M5
S3260 M5
The following table lists the BIOS token names, including the defaults and values for each supported M5 platform in this release.
Name
Default Value
M5 Server Supported Values
Platform
Dependencies
Legacy USB Support
Enabled
Disabled , Enabled, Auto
All M5 Servers
FRB-2 Timer
Enabled
Enabled, Disabled
All M5 Servers
OS Boot Watchdog Timer Policy
Power Off
Power Off, Reset
All M5 Servers
Applicable only when OS Boot Watchdog Timer is Enabled.
OS Boot Watchdog Timer Timeout
10 minutes
5 minutes, 10 minutes, 15 minutes, 20 minutes
All M5 Servers
Applicable only when OS Boot Watchdog Timer is Enabled.
OS Boot Watchdog Timer
Disabled
Enabled, Disabled
All M5 Servers
Flow Control
None
None, RTS-CTS
All M5 Servers
Applicable only when Console Redirection is COM 0.
Baud Rate
115.2k
9.6k, 19.2k, 38.4k, 57.6k, 115.2k
All M5 Servers
Applicable only when Console Redirection is COM 0.
Terminal Type
VT100
PC-ANSI, VT100, VT100-PLUS, VT-UTF8
All M5 Servers
Applicable only when Console Redirection is COM 0.
Console Redirection
Disabled
COM 0, COM 1, Disabled
All M5 Servers
Number of Retries
13
Infinite, 5, 13
B200 M5
B480 M5
C480 M5
Applicable only when Boot Option Retry is Enabled.
Cool Down Time (sec)
90
15, 45, 90
B200 M5
B480 M5
C480 M5
Applicable only when Boot Option Retry is Enabled.
Boot Option Retry
Disabled
Enabled, Disabled
B200 M5
B480 M5
C480 M5
Trusted Platform Module (TPM)
Enabled
Enabled, Disabled
All M5 Servers
Intel Virtualization Technology
Enabled
Enabled, Disabled
All M5 Servers
Intel VT for directed IO
Enabled
Enabled, Disabled
All M5 Servers
Intel Trusted Execution Technology Support
Enabled
Enabled, Disabled
All M5 Servers
Can be Enabled only when Trusted Platform Module (TPM) is Enabled.
Enabling Intel Trusted Execution Technology Support auto enables Intel VT for directed IO andIntel Virtualization Technology.
Local X2 Apic
Disabled
Enabled, Disabled
All M5 Servers
Enabling Local X2 Apic auto enables Intel VT for directed IO.
Intel VTD coherency support
Disabled
Enabled, Disabled
All M5 Servers
Intel VTD ATS support Enabled
Enabled, Disabled
All M5 Servers
NUMA optimized
Enabled
Enabled, Disabled
All M5 Servers
Memory RAS configuration
Maximum Performance
Mirror Mode 1LM, Maximum Performance
All M5 Servers
Memory Mapped IO above 4GB
Enabled
Enabled, Disabled
All M5 Servers
Hardware Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
Adjacent Cache Line Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
DCU Streamer Prefetch
Enabled
Enabled, Disabled
All M5 Servers
DCU IP Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
Processor C1E
Disabled
Enabled, Disabled
All M5 Servers
Processor C6 Report
Disabled
Enabled, Disabled
All M5 Servers
Execute Disable Bit
Enabled
Enabled, Disabled
All M5 Servers
Intel Turbo Boost Tech
Enabled
Enabled, Disabled
All M5 Servers
P STATE Coordination
HW ALL
HW ALL, SW ALL, SW ANY
All M5 Servers
Boot Performance Mode
Max Performance
Max Performance, Max Efficient, Set by Intel NM
All M5 Servers
Enhanced Intel SpeedStep Tech
Enabled
Enabled, Disabled
All M5 Servers
Disabling Enhanced Intel SpeedStep Tech auto disables Intel Turbo Boost Tech.
Intel HyperThreading Tech
Enabled
Enabled, Disabled
All M5 Servers
CPU Performance
Custom
Enterprise, HPC, High Throughput, Custom
All M5 Servers
If set as Enterprise then:
If set as High Throughput then:
Hardware Prefetcher is Enabled
Adjacent Cache Line Prefetcher is Enabled
DCU Streamer Prefetch is Enabled
DCU IP Prefetcher is Enabled
If set as HPC then:
Hardware Prefetcher is Disabled
Adjacent Cache Line Prefetcher is Disabled
DCU Streamer Prefetch is Disabled
DCU IP Prefetcher is Enabled
Hardware Prefetcher is Enabled
Adjacent Cache Line Prefetcher is Enabled
DCU Streamer Prefetch is Enabled
DCU IP Prefetcher is Enabled
CDN Control
Enabled
Enabled, Disabled
All M5 Servers
Processor CMCI
Enabled
Enabled, Disabled
All M5 Servers
All Onboard LOM
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
If set as Disabled, then LOM Port 1 OptionROM and LOM Port 2 OptionROM are Disabled.
LOM Port 1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
LOM Port 2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
SBNVMe1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SBNVMe2 OptionROM
Enabled
Disabled, Enabled
S3260 M5
IOEMezz1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
IOENVMe1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
IOENVMe2 OptionROM
Enabled
Disabled, Enabled
S3260 M5
IOESlot1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
IOESlot2 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SBMezz1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SBMezz2 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SIOC1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SIOC2 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SIOCNvme1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SIOCNvme2 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SBLom1 OptionROM
Enabled
Disabled, Enabled
S3260 M5
SBNVMe1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SBNVMe2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SIOCNVMe1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SIOCNVMe2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SIOC1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SIOC2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SBMezz1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
SBMezz2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
IOESlot1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
IOESlot2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
IOEMezz1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
IOENVMe1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
IOENVMe2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
S3260 M5
PCIe Slot 1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
PCIe Slot 2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
PCIe Slot 3 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 4 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 5 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 6 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 7 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 8 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 9 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 10 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 11 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 12 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot MLOM OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot MRAID OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot RAID OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot N1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N3 OptionROM Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N4 OptionROM Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N5 OptionROM Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N6 OptionROM Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N7 OptionROM Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N8 OptionROM Enabled
Disabled, Enabled
C220 M5, C240 M5, C480 M5
PCIe Slot N9 OptionROM Enabled
Disabled, Enabled
C220 M5, C480 M5
PCIe Slot N10 OptionROM Enabled
Disabled, Enabled
C220 M5, C480 M5
PCIe Slot N11 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N12 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N13 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N14 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N15 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N16 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N17 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N18 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N19 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N20 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N21 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N22 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N23 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot N24 OptionROM Enabled
Disabled, Enabled
C480 M5
PCIe Slot Rear NVMe1 OptionROM
Enabled
Disabled, Enabled
C240 M5, C480 M5
PCIe Slot Rear NVMe2 OptionROM
Enabled
Disabled, Enabled
C240 M5, C480 M5
PCIe Slot Rear NVMe3 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot Rear NVMe4 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot Rear NVMe5 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot Rear NVMe6 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot Rear NVMe7 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot Rear NVMe8 OptionROM
Enabled
Disabled, Enabled
C480 M5
MRAID Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
RAID Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
MLOM Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
PCIe Slot 1 Link Speed
Auto
Disabled, Auto, GEN1 , GEN2, GEN3
C220 M5, C240 M5
C480 M5
PCIe Slot 2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
C480 M5
PCIe Slot 3 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 4 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 5 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 6 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 7 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 8 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 9 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 10 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 11 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 12 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
Front NVME1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
Front NVME2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
Rear NVME1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Rear NVME2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Power On Password
Disabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
P-SATA mode
LSI SW RAID
LSI SW RAID, Disabled
All M5 Servers
VGA Priority
OnBoard
OnBoard, OffBoard, OnBoard VGA Disabled
C220 M5, C240 M5
Core Multi Processing
All
All, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27
All M5 Servers
USB Port Front
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port Rear
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port KVM
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port VMedia
Enabled
Enabled, Disabled
C480 M5
USB Port Internal
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port SD Card
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
UEFI Boot Mode
Enabled
Enabled, Disabled
All M5 Servers
Workload Configuration
IO Sensitive
Balanced, IO Sensitive
All M5 Servers
IMC Interleave
Auto
1-way Interleave, 2-way Interleave, Auto
All M5 Servers
Sub NUMA Clustering
Disabled
Enabled, Disabled
All M5 Servers
KTI Prefetch
Enabled
Enabled, Disabled
All M5 Servers
XPT Prefetch
Disabled
Enabled, Disabled
All M5 Servers
Energy Performance Tuning
OS
OS, BIOS
All M5 Servers
If set as OS then Energy Performance is Balanced Performance.
If set as BIOS then, Energy Performance is Performance, Balanced Performance, Balanced Power, or Power.
Energy Performance
Balanced Performance
Performance, Balanced Performance, Balanced Power, Power
All M5 Servers
Package C State Limit
C0 C1 State
No Limit, Auto, C0 C1 State, C2, C6 Non Retention, C6 Retention
All M5 Servers
LLC Prefetch
Disabled
Enabled, Disabled
All M5 Servers
CPU Hardware Power Management
HWPM Native Mode
Disabled, HWPM Native Mode, HWPM OOB Mode, Native Mode with no Legacy
All M5 Servers
If set as HWPM OOB Mode then, ProcessorEppProfile is set as Performance, Balanced Performance, or Balanced Power, Power.
IPV6 PXE Support
Disabled
Enabled, Disabled
All M5 Servers
Energy Efficient Turbo
Disabled
Enabled, Disabled
All M5 Servers
Autonomous Core C-state
Disabled
Enabled, Disabled
All M5 Servers
ProcessorEppProfile
Balanced Performance
Performance, Balanced Performance, Balanced Power, Power
All M5 Servers
Patrol Scrub
Enabled
Enabled, Disabled
All M5 Servers
M5 Server BIOS Tokens in Release 3.2(2)
Cisco UCS Manager, Release 3.2(2) introduces B480 M5 and C480 M5 to the list of supported M5 platforms. The M5 platforms supported in this release are:
B200 M5
B480 M5
C220 M5
C240 M5
C480 M5
The following table lists the BIOS token names, including the defaults and values for each supported M5 platform in this release.
Name
Default Value
M5 Server Supported Values
Platform
Legacy USB Support
Enabled
Disabled , Enabled, Auto
All M5 Servers
FRB-2 Timer
Enabled
Enabled, Disabled
All M5 Servers
OS Boot Watchdog Timer Policy
Power Off
Power Off, Reset
All M5 Servers
OS Boot Watchdog Timer Timeout
10 minutes
5 minutes, 10 minutes, 15 minutes, 20 minutes
All M5 Servers
OS Boot Watchdog Timer
Disabled
Enabled, Disabled
All M5 Servers
Flow Control
None
None, RTS-CTS
All M5 Servers
Baud Rate
115.2k
9.6k, 19.2k, 38.4k, 57.6k, 115.2k
All M5 Servers
Terminal Type
VT100
PC-ANSI, VT100, VT100-PLUS, VT-UTF8
All M5 Servers
Console Redirection
Disabled
COM 0, COM 1, Disabled
All M5 Servers
Number of Retries
13
Infinite, 5, 13
B200 M5
B480 M5
C480 M5
Cool Down Time (sec)
90
15, 45, 90
B200 M5
B480 M5
C480 M5
Boot Option Retry
Disabled
Enabled, Disabled
B200 M5
B480 M5
C480 M5
Trusted Platform Module (TPM)
Enabled
Enabled, Disabled
All M5 Servers
Intel Virtualization Technology
Enabled
Enabled, Disabled
All M5 Servers
Intel VT for directed IO
Enabled
Enabled, Disabled
All M5 Servers
Intel Trusted Execution Technology Support
Enabled
Enabled, Disabled
All M5 Servers
Local X2 Apic
Disabled
Enabled, Disabled
All M5 Servers
Intel VTD coherency support
Disabled
Enabled, Disabled
All M5 Servers
Intel VTD ATS support Enabled
Enabled, Disabled
All M5 Servers
NUMA optimized
Enabled
Enabled, Disabled
All M5 Servers
Memory RAS configuration
Maximum Performance
Mirror Mode 1LM, Maximum Performance
All M5 Servers
Memory Mapped IO above 4GB
Enabled
Enabled, Disabled
All M5 Servers
Hardware Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
Adjacent Cache Line Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
DCU Streamer Prefetch
Enabled
Enabled, Disabled
All M5 Servers
DCU IP Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
Processor C1E
Disabled
Enabled, Disabled
All M5 Servers
Processor C6 Report
Disabled
Enabled, Disabled
All M5 Servers
Execute Disable Bit
Enabled
Enabled, Disabled
All M5 Servers
Intel Turbo Boost Tech
Enabled
Enabled, Disabled
All M5 Servers
P STATE Coordination
HW ALL
HW ALL, SW ALL, SW ANY
All M5 Servers
Boot Performance Mode
Max Performance
Max Performance, Max Efficient, Set by Intel NM
All M5 Servers
Enhanced Intel SpeedStep Tech
Enabled
Enabled, Disabled
All M5 Servers
Intel HyperThreading Tech
Enabled
Enabled, Disabled
All M5 Servers
CPU Performance
Custom
Enterprise, HPC, High Throughput, Custom
All M5 Servers
CDN Control
Enabled
Enabled, Disabled
All M5 Servers
Processor CMCI
Enabled
Enabled, Disabled
All M5 Servers
All Onboard LOM
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
LOM Port 1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
LOM Port 2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
PCIe Slot 1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
PCIe Slot 2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
C480 M5
PCIe Slot 3 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 4 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 5 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 6 OptionROM
Enabled
Disabled, Enabled
C240 M5
C480 M5
PCIe Slot 7 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 8 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 9 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 10 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 11 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot 12 OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot MLOM OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot MRAID OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot RAID OptionROM
Enabled
Disabled, Enabled
C480 M5
PCIe Slot N1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot N2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot Rear NVMe1 OptionROM
Enabled
Disabled, Enabled
C240 M5
PCIe Slot Rear NVMe2 OptionROM
Enabled
Disabled, Enabled
C240 M5
MRAID Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
RAID Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
MLOM Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
PCIe Slot 1 Link Speed
Auto
Disabled, Auto, GEN1 , GEN2, GEN3
C220 M5, C240 M5
C480 M5
PCIe Slot 2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
C480 M5
PCIe Slot 3 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 4 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 5 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 6 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
C480 M5
PCIe Slot 7 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 8 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 9 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 10 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 11 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
PCIe Slot 12 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C480 M5
Front NVME1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
Front NVME2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
Rear NVME1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Rear NVME2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Power On Password
Disabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
P-SATA mode
LSI SW RAID
LSI SW RAID, Disabled
C220 M5, C240 M5
VGA Priority
OnBoard
OnBoard, OffBoard, OnBoard VGA Disabled
C220 M5, C240 M5
Core Multi Processing
All
All, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27
All M5 Servers
USB Port Front
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port Rear
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port KVM
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port VMedia
Enabled
Enabled, Disabled
C480 M5
USB Port Internal
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
USB Port SD Card
Enabled
Enabled, Disabled
C220 M5, C240 M5
C480 M5
UEFI Boot Mode
Enabled
Enabled, Disabled
All M5 Servers
Workload Configuration
IO Sensitive
Balanced, IO Sensitive
All M5 Servers
IMC Interleave
Auto
1-way Interleave, 2-way Interleave, Auto
All M5 Servers
Sub NUMA Clustering
Disabled
Enabled, Disabled
All M5 Servers
KTI Prefetch
Enabled
Enabled, Disabled
All M5 Servers
XPT Prefetch
Disabled
Enabled, Disabled
All M5 Servers
Energy Performance Tuning
OS
OS, BIOS
All M5 Servers
Energy Performance
Balanced Performance
Performance, Balanced Performance, Balanced Power, Power
All M5 Servers
Package C State Limit
C0 C1 State
No Limit, Auto, C0 C1 State, C2, C6 Non Retention, C6 Retention
All M5 Servers
LLC Prefetch
Disabled
Enabled, Disabled
All M5 Servers
CPU Hardware Power Management
HWPM Native Mode
Disabled, HWPM Native Mode, HWPM OOB Mode, Native Mode with no Legacy
All M5 Servers
IPV6 PXE Support
Disabled
Enabled, Disabled
All M5 Servers
M5 Server BIOS Tokens in Release 3.2(1)
Cisco UCS Manager, Release 3.2(1) introduces support for M5 platforms. The M5 platforms supported in this release are:
B200 M5
C220 M5
C240 M5
The following table lists the BIOS token names, including the defaults and values for each supported M5 platform in this release.
Name
Default Value
M5 Server Supported Values
Platform
Legacy USB Support
Enabled
Disabled , Enabled, Auto
All M5 Servers
FRB-2 Timer
Enabled
Enabled, Disabled
All M5 Servers
OS Boot Watchdog Timer Policy
Power Off
Power Off, Reset
All M5 Servers
OS Boot Watchdog Timer Timeout
10 minutes
5 minutes, 10 minutes, 15 minutes, 20 minutes
All M5 Servers
OS Boot Watchdog Timer
Disabled
Enabled, Disabled
All M5 Servers
Flow Control
None
None, RTS-CTS
All M5 Servers
Baud Rate
115.2k
9.6k, 19.2k, 38.4k, 57.6k, 115.2k
All M5 Servers
Terminal Type
VT100
PC-ANSI, VT100, VT100-PLUS, VT-UTF8
All M5 Servers
Console Redirection
Disabled
COM 0, COM 1, Disabled
All M5 Servers
Number of Retries
13
Infinite, 5, 13
B200 M5
Cool Down Time (sec)
90
15, 45, 90
B200 M5
Boot Option Retry
Disabled
Enabled, Disabled
B200 M5
Trusted Platform Module (TPM)
Enabled
Enabled, Disabled
All M5 Servers
Intel Virtualization Technology
Enabled
Enabled, Disabled
All M5 Servers
Intel VT for directed IO
Enabled
Enabled, Disabled
All M5 Servers
Local X2 Apic
Disabled
Enabled, Disabled
All M5 Servers
Intel VTD coherency support
Disabled
Enabled, Disabled
All M5 Servers
Intel VTD ATS support Enabled
Enabled, Disabled
All M5 Servers
NUMA optimized
Enabled
Enabled, Disabled
All M5 Servers
Memory RAS configuration
Maximum Performance
Mirror Mode 1LM, Maximum Performance
All M5 Servers
Memory Mapped IO above 4GB
Enabled
Enabled, Disabled
All M5 Servers
Hardware Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
Adjacent Cache Line Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
DCU Streamer Prefetch
Enabled
Enabled, Disabled
All M5 Servers
DCU IP Prefetcher
Enabled
Enabled, Disabled
All M5 Servers
Processor C1E
Disabled
Enabled, Disabled
All M5 Servers
Processor C6 Report
Disabled
Enabled, Disabled
All M5 Servers
Execute Disable Bit
Enabled
Enabled, Disabled
All M5 Servers
Intel Turbo Boost Tech
Enabled
Enabled, Disabled
All M5 Servers
P STATE Coordination
HW ALL
HW ALL, SW ALL, SW ANY
All M5 Servers
Boot Performance Mode
Max Performance
Max Performance, Max Efficient, Set by Intel NM
All M5 Servers
Enhanced Intel SpeedStep Tech
Enabled
Enabled, Disabled
All M5 Servers
Intel HyperThreading Tech
Enabled
Enabled, Disabled
All M5 Servers
CPU Performance
Custom
Enterprise, HPC, High Throughput, Custom
All M5 Servers
CDN Control
Enabled
Enabled, Disabled
All M5 Servers
All Onboard LOM
Enabled
Enabled, Disabled
C220 M5, C240 M5
LOM Port 1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
LOM Port 2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot 1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot 2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot 3 OptionROM
Enabled
Disabled, Enabled
C240 M5
PCIe Slot 4 OptionROM
Enabled
Disabled, Enabled
C240 M5
PCIe Slot 5 OptionROM
Enabled
Disabled, Enabled
C240 M5
PCIe Slot 6 OptionROM
Enabled
Disabled, Enabled
C240 M5
PCIe Slot MLOM OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot MRAID OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot N1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot N2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot Rear NVMe1 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
PCIe Slot Rear NVMe2 OptionROM
Enabled
Disabled, Enabled
C220 M5, C240 M5
MRAID Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
MLOM Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
PCIe Slot 1 Link Speed
Auto
Disabled, Auto, GEN1 , GEN2, GEN3
C220 M5, C240 M5
PCIe Slot 2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
PCIe Slot 3 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
PCIe Slot 4 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
PCIe Slot 5 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
PCIe Slot 6 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Front NVME1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
Front NVME2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C220 M5, C240 M5
Rear NVME1 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Rear NVME2 Link Speed
Auto
Disabled, Auto, GEN1, GEN2, GEN3
C240 M5
Power On Password
Disabled
Enabled, Disabled
C220 M5, C240 M5
VGA Priority
OnBoard
OnBoard, OffBoard, OnBoard VGA Disabled
C220 M5, C240 M5
Core Multi Processing
All
All, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27
All M5 Servers
USB Port Front
Enabled
Enabled, Disabled
C220 M5, C240 M5
USB Port Rear
Enabled
Enabled, Disabled
C220 M5, C240 M5
USB Port KVM
Enabled
Enabled, Disabled
C220 M5, C240 M5
USB Port Internal
Enabled
Enabled, Disabled
C220 M5, C240 M5
USB Port SD Card
Enabled
Enabled, Disabled
C220 M5, C240 M5
P-SATA mode
LSI SW RAID
LSI SW RAID, Disabled
C220 M5, C240 M5
UEFI Boot Mode
Enabled
Enabled, Disabled
All M5 Servers
Workload Configuration
NUMA
NUMA, UMA
All M5 Servers
IMC Interleave
1-way Interleave
1-way Interleave, 2-way Interleave
All M5 Servers
Sub NUMA Clustering
Enabled
Enabled, Disabled
All M5 Servers
KTI Prefetch
Enabled
Enabled, Disabled
All M5 Servers
XPT Prefetch
Enabled
Enabled, Disabled
All M5 Servers
Energy Performance Tuning
OS
OS, BIOS
All M5 Servers
Energy Performance
Balanced Performance
Performance, Balanced Performance, Balanced Power, Power
All M5 Servers
Package C State Limit
C0 C1 State
No Limit, Auto, C0 C1 State, C2, C6 Non Retention, C6 Retention
All M5 Servers
LLC Prefetch
Enabled
Enabled, Disabled
All M5 Servers
CPU Hardware Power Management
HWPM Native Mode
Disabled, HWPM Native Mode, HWPM OOB Mode, Native Mode with no Legacy
All M5 Servers
IPV6 PXE Support
Enabled
Enabled, Disabled
All M5 Servers
Copyright © 2017-2018, Cisco Systems, Inc. All rights reserved.