C4200 Server Chassis Specifications
This appendix lists the physical, environmental, and power specifications for the server chassis.
Physical Specifications
The following table lists the physical specifications for the C4200 server chassis.
Description |
Specification |
Height |
3.4 in. (87.2 mm) |
Width |
16.9 in. (429.3 mm) (width of the chassis rail-receiving surface; not including front latch-handles) |
Depth (length) |
Server only: 32.6 in. (827.6 mm) Server with Cisco slide rails and CMA: 38.0 in (965.2 mm) |
Maximum weight (fully loaded chassis with four compute nodes) |
95.8 lb. (43.5 Kg) |
Environmental Specifications
The following table lists the environmental requirements for the C4200 server chassis.
Description |
Specification |
Temperature, Operating |
41 to 95°F (5 to 35°C) Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level. For more information, see the Cisco Unified Computing System Site Planning Guide: Data Center Power and Cooling. |
Temperature, non-operating (when the server is stored or transported) |
–40 to 149°F (–40 to 65°C) |
Humidity (RH), operating |
10 to 90% |
Humidity (RH), non-operating (when the server is stored or transported) |
5 to 93% |
Altitude, operating |
0 to 10,000 feet |
Altitude, non-operating (when the server is stored or transported) |
0 to 40,000 feet |
Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.5 |
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
40 |
Power Specifications
Note |
Do not mix power supply types or wattages in the server. Both power supplies must be identical. |
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
2400 W AC Power Supply
This section lists the specifications for each 2400 W AC power supply (Cisco part number UCSC-PSU3-2400W).
Description |
Specification |
AC Input Voltage |
Nominal range: 200–240 VAC (Range: 180–264 VAC) |
AC Input Frequency |
Nominal range: 50 to 60Hz (Range: 47–63 Hz) |
Maximum AC Input current |
16 A at 200 VAC |
Maximum inrush current |
35 A at 35° C |
Maximum output power per PSU |
2400 W at 200–240 VAC |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
Climate Savers Platinum Efficiency (80Plus Platinum certified) |
Form factor |
RSP2 |
Input connector |
IEC60320 C20 |