Technical Specifications

Switch Specifications

Environmental

Specification

C6816-X-LE

C6832-X-LE

C6824-X-LE-40G

C6840-X-LE-40G

Temperature, operating

32°F to 104°F (0 to 40°C)

32°F to 104°F (0 to 40°C)

32°F to 104°F (0 to 40°C)

32°F to 104°F (0 to 40°C)

Temperature, nonoperating and storage

-4 to 149°F (-20 to 65°C)

-4 to 149°F (-20 to 65°C)

-4 to 149°F (-20 to 65°C)

-4 to 149°F (-20 to 65°C)

Thermal transition

0.5°C per minute (hot to cold)

0.33°C per minute (cold to hot)

0.5°C per minute (hot to cold)

0.33°C per minute (cold to hot)

0.5°C per minute (hot to cold)

0.33°C per minute (cold to hot)

0.5°C per minute (hot to cold)

0.33°C per minute (cold to hot)

Humidity (RH), ambient (noncondensing operating)

5% to 90%

Humidity (RH), ambient (noncondensing nonoperating and storage)

5% to 95%

Altitude, operating

Certified for operation: 0 to 6500 ft (0 to 2000 m)

Designed and tested for operation: -200 to 10,000 ft (-60 to 3000 m)

Shock and vibration

Shock
  • Operational - 5 G 30 ms, half-sine (IEC 68-2-27)

  • Nonoperational - 20 G, 7.5 ms, trapezoidal

Vibration

  • Operational - 3 Hz to 500 Hz

  • Power Spectral Density (PSD) - 0.0005 G2/Hz at 10 Hz and 200 Hz. 5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grams).

Acoustic noise

Sound power level, 67 dB@27°C

Physical characteristics

Dimensions

  • Height = 3.47 inches (8.81 cm)

  • Width = 17.35 inches (44.07 cm)

  • Depth = 21.8 inches (55.38 cm)

  • Rack Units (RU) = 2 RU

Weight

Chassis with 2 power supplies and a built-in fan

24.04 lbs/10.09 kgs

33.95 lbs/15.4 kgs

34.83 lbs/15.8 kgs

37.03 lbs/16.8 kgs

Airflow

C6840-X-FAN
Note 

The airflow in the Catalyst 6840-X switch chassis is from front to back. See Site Requirements for recommended separations between walls and the chassis air intake and air exhaust and between the air exhaust of one chassis with the air intake of another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail.

Power Supply Module Specifications

C6840-X-750W-AC=

C6840-X-750W-DC=

C6840-X-1100W-AC=

C6840-X-1100W-DC=

Physical specifications

12.5"x2.15'x1.57'

Input voltage range

90Vac to 264Vac

-40Vdc to -72Vdc

90Vac to 264Vac

-40Vdc to -72Vdc

Input frequency range

50/60Hz

N/A

50/60Hz

N/A

Input current (each input)

less than 10A

max 25A @40V or greater

max 13A @100Vac

max 7A @200Vac

max 32A @40V or greater

Rush-in current

35A cold turn-on

50A hot turn-on

90A

35A cold turn-on

50A hot turn-on

90A

Power supply input receptacles

IEC 60320

PC 5/ 2-STF-7,62

IEC 60320

PC 5/ 2-STF-7,62

Power cord rating

15A (US), 10A (international)

15A (US), 10A (international)

British thermal units (BTUs)

2559 BTU/hour

2559 BTU/hour

3753 BTU/hour

3753 BTU/hour

Output holdup time

16 milliseconds at 100% load

4msec at 100% load

16 milliseconds at 100% load

4msec at 100% load

Environmental conditions

Operating temperature: -5C to 55oc at 1800m(6000ft)

-5C to 55C at 1800m(6000ft)

Operating temperature: -5C to 55oc at 1800m(6000ft)

-5C to 55C at 1800m(6000ft)

Power Supply AC Power Cords

The following table lists the specifications for the AC power cords that are available for the AC-input power supply. The table also includes references to power cord illustrations.

Table 1. Power Supply AC Power Cords

Power Cords

CAB-250V-10A-AR

AC Power Cord - 250V, 10A - Argentina(2.5 meter)

CAB-9K10A-AU

Power Cord, 250VAC 10A 3112 Plug, Australia(2.5 meter)

CAB-250V-10A-BR

AC Power Cord - 250V, 10A - Brazil (2.1 meter)

CAB-250V-10A-CN

AC Power Cord - 250V, 10A - PRC(2.5 meter)

CAB-9K10A-EU

Power Cord, 250VAC 10A CEE 7/7 Plug, EU(2.5 meter)

CAB-IND-10A

10A Power cable for India(2.5 meter)

CAB-250V-10A-IS

AC Power Cord - 250V, 10A - Israel(2.5 meter)

CAB-9K10A-IT

Power Cord, 250VAC 10A CEI 23-16/VII Plug, Italy(2.5 meter)

CAB-250V-10A-ID

AC Power Cord - 250V, 10A, South Africa (2.5 meter)

CAB-9K10A-SW

Power Cord, 250VAC 10A MP232 Plug, SWITZ(2.5 meter)

CAB-9K10A-UK

Power Cord, 250VAC 10A BS1363 Plug (13 A fuse), UK(2.5 meter)

CAB-9K12A-NA

Power Cord, 125VAC 13A NEMA 5-15 Plug, North America(2.5 meter)

CAB-AC-250V/13A

North America, NEMA L6-20 250V/20A plug-IEC320/C13 receptacle(2.0 meter)

CAB-N5K6A-NA

Power Cord, 200/240V 6A North America(2.5 meter)

CAB-C13-CBN

Cabinet Jumper Power Cord, 250 VAC 10A, C14-C13 Connectors(0.7 meter)

CAB-C13-C14-2M

Power Cord Jumper, C13-C14 Connectors, 2 Meter Length(2 meter)

CAB-C13-C14-AC

Power cord, C13 to C14 (recessed receptacle), 10A(3 meter)

Fan Tray Module Specifications

Physical Specification

Dimensions (H x D x W)

3.0'' (H)X 12.7''(W) X1.774''(D)

Weight

1.08 Kg

Operating Specification

Airflow

120 CFM

Chassis and Module Power and Heat Values

Module Type

Module Current (A)

Module Power (Watts)

AC-Input Power (Watts)

AC Heat Diss (BTU/HR)

DC Input Power (Watts)

DC Heat Diss (BTU/HR)

FAN 9 A 108 W 132 W 450BTU/HR 132 W 450BTU/HR

Catalyst 6816-X-LE

35 A 420 W 750 W 2559BTU/HR 750 W 2559BTU/HR

Catalyst 6832-X-LE

52 A 620 W 750 W 2559BTU/HR 750 W 2559BTU/HR

Catalyst 6824-X-LE-40G

52 A 620 W 750 W 2559BTU/HR 750 W 2559BTU/HR

Catalyst 6840-X-LE-40G

75 A 900 W 1100 W 3753BTU/HR 1100 W 3753BTU/HR