Cisco CSP 2100 X2 Specifications

This appendix lists the technical specifications for Cisco CSP 2100 X2 and includes the following sections:

Physical Specifications

Table 9-1 lists the physical specifications for Cisco CSP 2100 X2.

Table 9-1 Physical Specifications

Description
Specification

Height

3.4 in. (8.70 cm)

Width (including slam latches)

19.0 in. (48.26 cm)

Depth (length)

Depth, including slam latches and power supply handles

29.0 in. (73.70 cm)

31.5 in. (80.00 cm)

Maximum Weight (fully loaded)

SFF 24-drive: 62.7 lb. (28.4 Kg)

Power Specifications

The power specifications for the four power supply options are listed in the following sections:

1200 W AC Power Supply

Table 9-2 lists the specifications for each 1200 W AC power supply
(Cisco part number UCSC-PSU2V2-1200W=).

 

Table 9-2 Power Supply Specifications

Description
Specification

AC input voltage

Nominal range: 100–120 VAC, 200–240 VAC

(Range: 90–132 VAC, 180–264 VAC)

AC input frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC input current

11 A at 100 VAC

7 A at 200 VAC

Maximum input volt-amperes

1456 VA

Maximum output power per PSU

800 W at 100–120 VAC

1200 W at 200–240 VAC

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

12 ms at 1200 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP1

Input connector

IEC320 C14

930 W DC (Version 2) Power Supply

Table 9-3 lists the specifications for each 930 W DC power supply
(Cisco part number UCSC-PSU2V2-930DC=).

 

Table 9-3 930 W DC Power Supply Specifications

Description
Specification

DC input voltage range

Nominal range: –48 to –60 VDC nominal

(Range: –40 to –60 VDC)

Maximum DC input current

28 A at –40 VDC

Maximum input W

1104 W

Maximum output power per PSU

930 W

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

5 ms at 930 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

> 92% at 50% load

Form factor

RSP1 (C-Series 2U and 4U servers)

Input connector

Fixed 3-wire block

Environmental Specifications

Table 9-4 lists the environmental specifications for the Cisco CSP 2100 X2.

 

Table 9-4 Environmental Specifications

Description
Specification

Temperature, operating

41 to 95°F (5 to 35°C)
Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level.

Temperature, nonoperating

(when the Cisco CSP 2100 X2 is in storage or is transported)

–40 to 149°F (–40 to 65°C)

Humidity (RH), operating

10 to 90%

Humidity, non-operating

5 to 93%

Altitude, operating

0 to 10,000 feet

Altitude, nonoperating

(when the Cisco CSP 2100 X2 is in storage or is transported)

0 to 40,000 feet

Sound power level
Measure A-weighted per ISO7779 LwAd (Bels)
Operation at 73°F (23°C)

5.8

Sound pressure level
Measure A-weighted per ISO7779 LpAm (dBA)
Operation at 73°F (23°C)

43