Alarm Troubleshooting
This chapter gives a description, severity, and troubleshooting procedure for each commonly encountered Cisco NCS 1001 alarm and condition. When an alarm is raised, refer to its clearing procedure.
0/PM [0|1] Unit Unsupported
Default Severity: Critical (CR), Service Affecting (SA)
Logical Object: EQUIPMENT
The 0/PM [0|1] Unit Unsupported alarm is raised when a an usupported PSU is plugged within NCS1001 chassis. The alarms has two forms because of the two PSU:
- 0/PM0 unit unsupported
- 0/PM1 unit unsupported
Clear the 0/PM [0|1] Unit Unsupported Alarm
Procedure
Replace the PSU with correct part number and hardware revision. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
0/RP0 Unit Unsupported
Default Severity: Critical (CR), Service Affecting (SA)
Logical Object: EQUIPMENT
The 0/RP0 Unit Unsupported alarm is raised when an unsupported CPU board is plugged in the chassis.
Clear the 0/RP0 Unit Unsupported Alarm
Procedure
Replace the control board with a proper part number and or hardware revision If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AMPLI-GAIN-LOW, AMPLI-GAIN-HIGH
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: OTS
The Amplifier Gain Low or High alarm is raised when the EDFA module cannot reach the gain setpoint. This condition occurs if the amplifier reaches its range boundaries.
Clear the AMPLI-GAIN-LOW, AMPLI-GAIN-HIGH Alarm
Procedure
Step 1 |
If the Amplifier-control-mode is set to "Manual", the applied gain comes from configuration. You need to adjust the gain setting to a correct value (not too low or too high). |
Step 2 |
If the Amplifier-Control-Mode is set to "Automatic" it may be due to a too long/too short span or other conditions (i.e. measured channels). Check the overall system settings and performance. |
Step 3 |
If the alarm persist, it may indicate an amplifier hardware failure. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AUTO-AMPLI-DISABLED
Default Severity: Minor (MN), Not-Service-Affecting (NSA)
Logical Object: OTS
The Amplifier Automatic Control Disabled alarm is raised when the amplifier is working in automatic mode and there is a channel disequalization. Hence the control algorithm cannot calculate proper gain.
Clear the AUTO-AMPLI-DISABLED Alarm
Procedure
Step 1 |
Check the OTS-OCH power levels in input and output of the amplifier. |
Step 2 |
The minimum channel power value and maximum channel power value shall be outside the channel-power-max-delta. |
Step 3 |
Review the channel plan at system level (channel launch power vs channel path) and increase the channel-power-max-delta. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AUTO-AMPLI-CTRL-DISABLED
Default Severity: NotAlarmed (NA), Not-Service-Affecting (NSA)
Logical Object: OTS
The AUTO-AMPLI-CTRL-DISABLED alarm is raised when the amplifier is working in automatic mode and channel peak to peak disequalization greater than the channel-power-max-delta configured.
Clear the AUTO-AMPLI-CTRL-DISABLED Alarm
Procedure
Step 1 |
(Option 1) Review the channel plan at system level. One or more channels may have power problems compared to others. |
Step 2 |
(Option 2) Check the OTS-OCH power levels in output of the amplifier. The minimum channel power value and maximum channel power value shall be outside the channel-power-max-delta. |
Step 3 |
Review the channel plan at system level (channel lauch power versus channel path) and increase the channel-power-max-delta. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AUTO-AMPLI-MISMATCH
Default Severity: NotAlarmed (NA), Not-Service-Affecting (NSA)
Logical Object: OTS
The Amplifier Automatic Configuration Mismatch alarm is raised when the amplifier-control-mode is configured as auto but there is no grid mode configuration. Hence the amplifier control cannot work.
Clear the AUTO-AMPLI-MISMATCH Alarm
Procedure
Step 1 |
Cisco NCS1001 configuration depends on how the system works (automatic control vs manual control). |
Step 2 |
Check Cisco NCS1001 running configuration using show running config command. |
Step 3 |
Enter the grid-mode configuration for the EDFA module, if required. |
Step 4 |
Change the amplifier configuration in manual mode, if required. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AUTO-AMPLI-RUNNING
Default Severity: NotAlarmed (NA), Not-Service-Affecting (NSA)
Logical Object: OTS
The Automatic Amplifier Running alarm is raised when the internal algorithm performs calculation to reach the target power. The alarm notifies the user that the final power is not reached.
Clear the AUTO-AMPLI-RUNNING Alarm
Procedure
The Automatic Amplifier Running alarm clears automatically when the target power is reached. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AUTO-LASER-SHUT
Default Severity: NotAlarmed (NA), Not-Service-Affecting (NSA)
Logical Object: OTS
The Amplifier Laser Shutdown alarm is raised for safety concern. If an OTS port supports an amplifier and the safety-control-mode is set to "auto", the amplifier may shut down its Tx power if it is not receiving the same Rx port due to a fiber cut.
Clear the AUTO-LASER-SHUT Alarm
Procedure
Step 1 |
For Controller OTS 1 (LINE), check the RX-LOC or RX-LOSP alarm. For Controller OTS 0 (COM), check if any RX-POWER-FAIL-LOW on Controller OTS 3 (COM-CHECK). |
Step 2 |
Check the fiber is properly plugged or if there is no fiber cut on the span. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
AUTO-POW-RED
Default Severity: NotAlarmed (NA), Not-Service-Affecting (NSA)
Logical Object: OTS
The Automatic Power Reduction alarm is raised when the temporary conditions in the amplifier restarts hence pulsing the APR power levels.
Clear the AUTO-POW-RED Alarm
Procedure
Step 1 |
Wait for the APR cycles complete, say, 100 seconds, 8 seconds APR levels. The alarms disappear once the amplifier ends the APR phase. |
Step 2 |
If the alarm persist check the fiber cut is repaired. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Ctrl-FPGA PCIe Error
Default Severity: Critical (CR), Service Affecting (SA)
Logical Object: EQUIPMENT
The Ctrl-FPGA PCIe error is raised when the Contro FPGA is unreachable due to PCIe bus error.
Clear the Ctrl-FPGA PCIe Error Alarm
Procedure
Reload Cisco NCS1001. If the alarm does not clear it may due to the hardware failure. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Daisyduke - FPGA PCIe Error
Default Severity: Critical (CR), Service Affecting (SA)
Logical Object: EQUIPMENT
The Daisyduke - FPGA PCIe error alarm occurs when the Daisy Duke CPU FPGA is unable to communicate with the CPU controller due to a Peripheral Component Interconnect Express (PCIe) error.
Clear the Daisyduke - FPGA PCIe Error Alarm
Procedure
Step 1 |
Reload the chassis. |
Step 2 |
If not cleared it may be due to hardware fault. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Daisyduke Processor Hot Alarm
Default Severity: Minor(MN), Non-Service Affecting (NSA)
Logical Object: EQUIPMENT
The Daisyduke Processor Hot alarm is raised when the CPU detects high temperature of the Processor.
Clear the Daisyduke Processor Hot Alarm
Procedure
Verify proper functioning of all the fans in the system. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
EQPT-DEGRADE-<n>
Default Severity: MINOR (MN), Not-Service-Affecting (SA)
Logical Object: EQUIPMENT
The Equipment Degrade alarm is raised when there is misbehavior detected by the optical module however the module is still considered as working properly.
Clear the EQPT-DEGRADE-<n> Alarm
Procedure
The Module is still working but requires further diagnosis. Plan for a module replacement. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
EQPT-FAIL-<n>
Default Severity: Critical (SA), Service-Affecting (SA)
Logical Object: EQUIPMENT
The Equipment Failure alarms is rasied on an optical module equipment that has an internal failure or is not able to commucate with the NCS1001 chassis.
Clear the EQPT-FAIL-<n> Alarm
Procedure
Step 1 |
From admin plane try to trigger a module reset (this opertaion is traffic affecting). |
Step 2 |
If the problem persist it typically indicate an internal hardware failure for the optical module. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Ethernet Switch Communication Error
Default Severity: Major (MN), Service Affecting (SA)
Logical Object: EQUIPMENT
The Ethernet Switch Communication error is raised when the interconnected board is unable to communicate with CPU due to a Peripheral Component Interconnect Express (PCIe).
Clear the Ethernet Switch Communication Error Alarm
Procedure
Power Cycle the Cisco NCS1001. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Fan Tray Removal Alarm
Default Severity: Minor (MN), Not-Service-Affecting (NSA)
Logical Object: FT
The Fan Tray Removal alarm is raised when the fan tray is removed from Cisco NCS1001 chassis.
Clear the Fan Tray Removal Alarm
Procedure
Insert the missing or removed fan tray. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
FPDs are Incompatible - Need to Upgrade all the FPDs
Default Severity: Major (MN), Service Affecting (SA)
Logical Object: EQUIPMENT
The FPDs are incompatible - need to upgrade all the FPDs alarm is raised when FPDs are incompatible.
Clear the FPDs are Incompatible - Need to Upgrade all the FPDs Alarm
Procedure
Update the firmware. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
I2C Access Error
Default Severity: Major (MN), Service Affecting (SA)
Logical Object: EQUIPMENT
The I2C access error alarm is raised when Cisco NCS1001 detect errors in interconnected card I2C busses.
Clear the I2C Access Error Alarm
Procedure
This alarm indicates hardware failure. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
[Low | High] Voltage Alarm
Default Severity: Critical (CR), Service Affecting (SA)
Logical Object: EQUIPMENT
A [Low | High] Voltage alarm is raised when one of the internal voltage measurement is not within the operating range. The format of the voltage alarm is:
- [sensor name]: high voltage alarm.
- [sensor name]: low voltage alarm.
Clear the [Low | High] Voltage Alarm
Procedure
Voltage alarms clears when the voltage is within the operating conditions. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
More than One Fan Tray is Removed from Chassis
Default Severity: Critical (CR), Not-Service-Affecting (NSA)
Logical Object: EQUIPMENT
This alarm is raised when more than one fan tray is removed from Cisco NCS1001 chassis.
Clear the More than One Fan Tray is Removed from Chassis Alarm
Procedure
Step 1 |
Check if at least three fan trays are inserted. |
Step 2 |
Ensure that there is no fan tray failure. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
OTDR-EXCESSIVE-ORL-[1|2]-[TX|RX]
Default Severity: Critical (CR), Not Service Affecting (NSA)
Logical Object: EQUIPMENT
The OTDR-EXCESSIVE-ORL-[1|2]-[TX|RX] alarm is raised when the OTDR scan detects an excessive Optical Return Loss (ORL) value. For example, this alarm is raised when the ORL read from OTDR module exceeds the relative threshold.
Clear the OTDR-EXCESSIVE-ORL-[1|2]-[TX|RX] Alarm
Procedure
Start a new OTDR scan on the same slot, port, and direction. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
OTDR-HIGH-REFLECTION-[1|2]-[TX|RX]
Default Severity: Critical (CR), Not Service Affecting (NSA)
Logical Object: EQUIPMENT
The OTDR-HIGH-REFLECTION-[1|2]-[TX|RX] alarm is raised when OTDR measurement with excessively high reflection is completed.
Clear the OTDR-HIGH-REFLECTION-[1|2]-[TX|RX] Alarm
Procedure
Start a new OTDR scan on the same slot, port, and direction. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
OTDR-RUNNING-NEAR-END-[1|2]-[TX|RX]
Default Severity: Not-Alarm (NA), Not-Service-Affecting (NSA)
Logical Object: EQUIPMENT
The OTDR-RUNNING-NEAR-END-[1|2]-[TX|RX] alarm is raised when an OTDR scan is in progress and OTDR [1|2] is locally performing a [Tx|Rx] measurement.
This alarm indicates that an OTDR scan is ongoing.
Clear the OTDR-RUNNING-NEAR-END-[1|2]-[TX|RX] Alarm
Procedure
This alarm is automatically cleared when OTDR scan is completed. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
OTDR-SCAN-FAIL-[1|2]-[TX|RX]
Default Severity: Critical (CR), Not Service Affecting (NSA)
Logical Object: EQUIPMENT
The OTDR-SCAN-FAIL-[1|2]-[TX|RX] alarm is raised when OTDR scan failed.
This alarm is raised when OTDR scan failed.
Clear the OTDR-SCAN-FAIL-[1|2]-[TX|RX] Alarm
Procedure
Start a new OTDR scan on the same slot, port, and direction. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Out of Tolerance Fault
Default Severity: Minor (MN), Not-Service-Affecting (NSA)
Logical Object: EQUIPMENT
An Out of Tolerance alarm is raised when a sensor detects wrong working condition. The alarm appears in the following format of:
- [sensor name]: out of tolerance fault.
Clear the Out of Tolerance Fault Alarm
Procedure
Check the sensor for hardware failure. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Error (PM_I2C_ACCESS_ERROR)
Default Severity: Major (MJ), Service Affecting (SA)
Logical Object: PEM
The Power Module Error (PM_I2C_ACCESS_ERROR) alarm is raised when there is an error on the power module. The detected error is a communication error on I2C bus.
Clear the Power Module Error (PM_I2C_ACCESS_ERROR) Alarm
Procedure
Check the health status of PEM module through the admin console. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Error (PM_NO_INPUT_DETECTED)
Default Severity: Major (MJ), Service Affecting (SA)
Logical Object: PEM
The Power Module Error (PM_NO_INPUT_DETECTED) alarm is raised when there is an error on the power module. This error is detected when the input power is not available.
Clear the Power Module Error (PM_NO_INPUT_DETECTED) Alarm
Procedure
Check the health status of PEM module using the admin console. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Error (PM_VIN_VOLT_OOR)
Default Severity: Major (MJ), Service Affecting (SA)
Logical Object: PEM
The Power Module Error (PM_VIN_VOLT_OOR) alarm is raised when there is an out of range input voltage issue on the power module.
Clear the Power Module Error (PM_VIN_VOLT_OOR) Alarm
Procedure
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Output Disabled (PM_OUTPUT_EN_PIN_HI)
Default Severity: Major (MJ), Service Affecting (SA)
Logical Object: PEM
The Power Module Output Disabled (PM_OUTPUT_EN_PIN_HI) alarm is raised when the output power is disabled and PEM module does not work.
Clear the Power Module Output Disabled (PM_OUTPUT_EN_PIN_HI) Alarm
Procedure
Enable the power supply to clear the alarm. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Overloaded (PM_POWER_LIMITED)
Default Severity: Major (MJ), Service Affecting (SA)
Logical Object: PEM
The Power Module Overloaded (PM_POWER_LIMITED) alarm is raised when there is power limitation control in the Power module.
Clear the Power Module Overloaded (PM_POWER_LIMITED) Alarm
Procedure
Check the health status of the PEM module through the admin console. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Redundancy Lost
Default Severity: Major (MJ), Service Affecting (SA)
Logical Object: PEM
The Power Module Redundancy Lost alarm is raised when any one of the two active power module is removed from the chassis.
Clear the Power Module Redundancy Lost Alarm
Procedure
This alarm is cleared when an active power supply module is inserted on Cisco NCS 1001. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Warning (Low Input Voltage)
Default Severity: Minor (MN), Not-Service-Affecting (NSA)
Logical Object: PEM
The Power Module Warning (Low Input Voltage) alarm is raised when the input power reaches warning level.
Clear the Power Module Warning (Low Input Voltage) Alarm
Procedure
Check the PEM module power supply. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Warning (PM_FAN_OUT_OF_TOLERANCE)
Default Severity: Minor (MN), Not-Service-Affecting (NSA)
Logical Object: PEM
The Power Module Warning (PM_FAN_OUT_OF_TOLERANCE) alarm is raised when there is a warning on the power module. The detected problem is a PSU fan out during normal working condition.
Clear the Power Module Warning (PM_FAN_OUT_OF_TOLERANCE) Alarm
Procedure
Check the health status of the PEM module through the admin console. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Power Module Warning (PM_OT_Warning)
Default Severity: Minor (MN), Not-Service-Affecting (NSA)
Logical Object: PEM
The Power Module Warning (PM_OT_Warning) is raised when the PEM Module reaches the warning level.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
RX-LOC
Default Severity: Critical (SA), Service-Affecting (SA)
Logical Object: OTS
The RX Loss Of Continuity (LOC) alarm is raised when there is a an optical power failure on the port receiving from a span. This alarm represents a fiber cut on the span and is a combination between RX-LOS-P and RX-POWER-FAIL-LOW.
Clear the RX-LOC Alarm
Procedure
Check the RX power reading on the ports received from the fiber spans. For EDFA Pluggable module, check the RX total power on OTS Port Controller 1 (LINE Port) and the TX power on OTS Port Controller 2 (OSC port). If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
RX-LOS-P
Default Severity: Critical (SA), Service-Affecting (SA)
Logical Object: OTS
The RX-LOS-P alarm is raised when there is an optical signal power loss on an OTS port as it transmits the signal.
Clear the RX-LOS-P Alarm
Procedure
Step 1 |
Check if the threshold settings is as per expected system performance. |
Step 2 |
Check if the receiving power is functional. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
RX-POWER-FAIL-LOW
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: OTS, OTS-OCH
The RX-POWER-FAIL-LOW alarm is raised when the transmit optical power is below the TX-low-threshold. This alarm is applicable to either OTS ports or OTS-OCH which represent optical channels.
Clear the RX-POWER-FAIL-LOW Alarm
Procedure
Step 1 |
Check if the threshold settings is as per expected system performance. |
Step 2 |
Check if the receiving power is correct or is missing due to a fiber cut or connected to a removed channel. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Sensor in a Failure State
Default Severity: Critical, Service Affecting
Logical Object: EQUIPMENT
The Sensor in a Failure State alarm is raised when there is a failure indication in the sensor.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).
SWITCH-TO-PROTECT
Default Severity: NotAlarmed (NA), Not-Service-Affecting
Logical Object: OTS
The Switch to Protect alarm is raised when the status of "Protect" Controller type is Active and the status of "Working" Controller is Standby status. (Only PSM OTS controllers 1 and 2 have these types).
Clear the SWITCH-TO-PROTECT Alarm
Procedure
This alarm is cleared when a switch event happens. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
Temperature Alarm
Default Severity: Critical (CR), Not Service Affecting (NSA)
Logical Object: EQUIPMENT
The Temperature alarm is raised when the temperature of a sensor exceeds normal operating range. The alarm appears in the form of:
- [sensor name]: temperature alarm.
Clear the Temperature Alarm
Procedure
Step 1 |
Verify the temperature of Cisco NCS1001 or the temperature of the optical modules displayed on the chassis. |
Step 2 |
Verify the environmental temperature of the room is not abnormally high. |
Step 3 |
Verify the functioning of fans and ensure that the air flow for the fans is proper. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |
TX-POWER-FAIL-LOW
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: OTS, OTS-OCH
The TX Power Fail Low alarm is raised when the transmit optical power is below the tx-low-threshold.
Clear the TX-POWER-FAIL-LOW Alarm
Procedure
Step 1 |
Check if the threshold settings are as per the expected system performance. |
Step 2 |
Check if the corresponding receiving power is correct. For example, an OTS Controller 1 TX receives power from Controller 0 RX. |
Step 3 |
Check for any hardware failure. If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447). |