After using the debug/refresh URL (i.e https://<IP Address of Splunk instance>:<PortNumber>/en-US/debug/refresh ) Splunk crashes and is no longer accessible until restarted.
This has been identified as a known issue when using the combination of forceTimebasedAutoLB=true and useAck=true in outputs.conf
ERROR debug:146 - Splunkd daemon is not responding: ('Error connecting to /servicesNS/nobody/search/admin/telemetry/_reload: [Errno 111] Connection refused',)
Received fatal signal 6 (Aborted) on PID 3321597.
Cause:
Signal sent by PID 3321597 running under UID 0.
Crashing thread: TcpOutEloop
$SPLUNK_HOME/bin/splunk btool outputs list | grep -E "forceTimebasedAutoLB|useACK"
useACK = true
forceTimebasedAutoLB = true
[tcpout]
forceTimebasedAutoLB = false
Please note the use of forceTimebasedAutoLB=true combined with useAck=true is not recommended and typically results in duplicate events being forwarded and indexed.
| Revision | Publish Date | Comments |
|---|---|---|
1.0 |
29-Sep-2026
|
Initial Release |