During startup, Splunk runs the locktest utility to validate if the filesystem is supported. Indexers are not starting up after upgrade to Splunk Enterprise version 8.1.x because of filesystem checks failure when executing the locktest utility. Before the upgrade, the indexers were able to pass the filesystem checks and start up successfully.
Here is the error message causing Splunk startup to fail:
$/opt/splunk/bin/splunk start
Splunk> Take the sh out of IT.Checking prerequisites...
Checking http port [8000]: open
Checking mgmt port [8089]: open
Checking appserver port [127.0.0.1:8065]: open
Checking kvstore port [8191]: open
Checking configuration... Done.
Checking critical directories... Done
Checking indexes...
coldPath='/opt/splunk_db/var/lib/splunk/<index>/colddb' of index=<index_name> on
unusable filesystem.
Validating databases (splunkd validatedb) failed with code '1'. If you cannot resolve
the issue(s) above after consulting documentation, please file a case online at
http://www.splunk.com/page/submit_issue
| Revision | Publish Date | Comments |
|---|---|---|
1.0 |
29-Sep-2026
|
Initial Release |