Guest

Cisco Unified Intelligent Contact Management Enterprise

How to Determine Whether an ICM Rockwell Spectrum PIM (spectpim) Is Offline or Has Gone Offline

Document ID: 42507



Contents

Introduction
Prerequisites
      Requirements
      Components Used
      Conventions
Problem
Solutions
      Process Window
      OPC Test
NetPro Discussion Forums - Featured Conversations
Related Information

Introduction

This document addresses the Cisco Intelligent Contact Management (ICM) Peripheral Gateway (PG) using the Rockwell Spectrum Peripheral Interface Manager (PIM) (spectpim) type. This document is a follow-up to the document How to Determine Whether a Cisco ICM PIM is Offline.

Prerequisites

Requirements

Cisco recommends that you have knowledge of these topics:

Components Used

The information in this document is based on these software and hardware versions:

  • Cisco ICM version 4.6.2 and later

  • Rockwell Spectrum ACD

The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.

Conventions

Refer to Cisco Technical Tips Conventions for more information on document conventions.

Problem

This document addresses how to determine whether a PG that is running the Rockwell Spectrum PIM (spectpim) is offline or has gone offline.

Solutions

This document references different tools and related documents that help you determine whether your PG is offline.

Process Window

Look at the physical status of the spectpim process that is running on the PG. The process window shows a status on the title bar:

Figure 1 – Process Window

Rockwell_PIM-1.gif

This list defines the individual states, in reference to that screen capture:

  • A—The PIM is active and is in communication with the Cisco ICM CallRouter and Symposium ACD.

  • I—The PIM is idle. Services are most likely active on the other side of the duplexed PG or are trying to activate.

  • C—The PIM is acquiring the active configuration from the Cisco ICM CallRouter and the Symposium ACD.

  • a/c—The PIM either is trying to activate or is just entering the configuration mode.

Note: Official state is not present unless the PIM is either active (A) or idle (I).

OPC Test

Another way to check whether the PG is online is to use the Open Peripheral Controller (OPC) Test (opctest command). This tool provides real-time status as to whether the PIM is active and how long it has been in this state. When you issue the status command from the opctest: prompt, you get output similar to this:

opctest: status

!--- Output suppressed.

PeripheralID  Side     State         LastStateChange           LastHeardFrom

 1             A    PIM_ACTIVE PR  03/13 22:18:32 (3.8 day)  03/17 17:47:07 (1 sec)

There are several other ways to determine whether the PG is offline. You can run a peripheral status node in Script Editor or view a Peripheral_Real_Time report from Monitor ICM. You can perform both of these checks from a Cisco ICM Administrative Workstation (AW).

Once you have determined that your spectpim is offline, you can use one of a few tools to help you determine why. See the Related Information section of this document for a list of suggested tools and documents that provide this guidance.

NetPro Discussion Forums - Featured Conversations

Networking Professionals Connection is a forum for networking professionals to share questions, suggestions, and information about networking solutions, products, and technologies. The featured links are some of the most recent conversations available in this technology.
NetPro Discussion Forums - Featured Conversations for Customer Contact Software
IP Communications and Video: Contact Center

Related Information



Updated: Sep 21, 2005Document ID: 42507