This section provides general system information on the IGX 8.
System Capacity:
1 shelf with 8 card slots.
Requires 2 dedicated front slot(s) for NPMs.
Requires 2 dedicated back slots for SCMs (1 slot with blank plate).
Up to 6 T1/E1 circuit ports.
Up to 6 T1/E1 packet trunks.
Up to 48 synchronous data ports.
Up to 25 Voice, Data, and/or Frame Relay Module groups.
AC system: 100 to 240 VAC (90-264 under-voltage and over-voltage tolerance), 47 to 63 Hz.
DC system: -42 to -56 VDC.
Each AC supply can provide up to 400 watts to the card shelves. Space for 4 power supplies.
Input AC Power
Connector:
IEC 16 Amp input connector. 6 different power cords are available to comply with the standards of individual countries. Power cords are 6 feet (about 2 meters) long. See appendix titled Cabling Summary in the IGX Installation Guide for details.
Current Requirements:
Configuration dependent - use Network Design Tool for exact requirements. For planning purposes, use the following:
♦ AC System
10 Amps Max. for 110 VAC, 5 A for 220 VAC.
♦ DC System
20 Amps max. at -48 VDC; 25 Amps at -42 VDC (worst case)
DC Input Connections
3-wire pluggable terminal block with screw terminal connectors.
Operating Environment:
0º to 40º C (32º to 104º F) normal operation (50º C up to 72 hours). Maximum 85% relative humidity.
1 or 2 shelves, each with 16 card slots.
Requires 1 or 2 dedicated front slot(s) for NPMs.
Requires 1 dedicated back slot for SCM.
Up to 16 T1/E1 circuit ports.
Up to 16 T1/E1 packet trunks.
Up to 100 synchronous data ports.
Up to 25 Voice, Data, and/or Frame Relay Module groups.
600 pounds (270 kilos) for a fully loaded IGX 32.
400 pounds (180 kilos) for a fully loaded IGX 16.
Clearance Requirement:
At least 30 inches front and rear clearance; nominal
12 inch side clearance.
Power Input Voltage:
AC system: 180 to 264 VAC, 47 to 63 Hz.
DC system: -42 to -56 VDC.
Each AC supply can provide up to 875 watts to a card shelf. Cabinet has space for 6 AC power supplies.
Current Requirements:
Configuration dependent: use Network Design Tool for exact requirements. For planning purposes, use the following:
♦ AC System
IGX 16/32: 16 Amps maximum at nominal voltage of 180 VAC.
♦ DC System
IGX 16: 24 Amps max. per circuit at -42 VDC (worst case)
IGX 32: 44 Amps at nominal -48 VDC; 50 Amps maximum per circuit at -42 VDC.
Input AC Power
Connector:
AC Power Distribution unit is the same for all cabinets shipped:
IEC 16 Amp input connector. Six different power cords available, depending on country of destination. See appendix titled "Cabling Summary" in the IGX Installation Manual for details.
DC Input Connections
DC power is the same for all IGX 16/32 cabinets shipped.
DC: 3-screw pluggable terminal connectors.
Operating Environment:
0º to 40º C (32º to 104º F) normal operation (50º C up to 72 hours).
Up to 85% relative humidity, non-condensing
Shock:
Withstands 10 G, 10 ms. at 1/2 sine wave.
Vibration:
Withstands 1/4 G, 20-500 Hz.
Heat Transfer to Room:
IGX 16: 4300 BTUs max, AC-powered system. 3600 BTUs in a DC-powered unit.
IGX 32: 8600 BTUs max, AC-powered system. 6800 BTUs in a DC-powered unit.
RS-232C/D, RS-449/422, V.24, X.21, and V.35
with IGX as DCE or DTE.
High-Speed Data Rates (HDM):
2.4 Kbps to 1.344 Mbps.
Low-Speed Data Rates:
2.4 to 19.2 Kbps per LDM port.
Ports per card:
LDI: 4 or 8.
SDI: 4.
Control Leads Supported:
SDI: Per interface standards.
SDI: Up to 7 in each direction for fast EIA.
LDI: 3 in each direction for DCE and DTE for each port.
Control Lead Sync
w/Data:
Control leads are sampled every 50 ms. and changes will normally follow data within 100 to 1000 msec. Fast EIA lead will be within 1 byte.
DS0A Interface:
Superrate, 56 Kbps to 512 Kbps (8 DS0s) per port.
Subrate: One 2.4/4.8/9.6/19.2/ or 56 Kbps per DS0
Per Bell TR-TSY-000458, TR-TSY-000280, TR-TSY-000083, and TR-TSY-000077.
Data Clocking:
Synchronous and isochronous clocking.
Normal, looped, and split clock configurations.
120 Ohms (balanced) or 75 Ohms (balanced or unbalanced)
Minimum Pulse Density:
Zero code suppression via HDB3 coding
Frame Format:
Unframed, 32-channel (G.703). Framed: 30 or 31-channel CEPT multiframe per ITU-T G.704.
VF Signalling:
CAS or CCS
Max. Line Lengths:
E1 output complies with G.703, so cabling must not exceed -6dB/1000 feet at 1024 kHz (applies to 75 Ohm coax or 120 Ohm twisted pair up to 350 meters or 1000 feet). StrataCom supplies cable with a maximum attenuation of 7 dB /1000 ft., so the maximum length of this cable is 850 feet (260 meters).
The following applies to each individual E1 line on the UFI-8E1:
Line Interface Connector
DB15 (120 Ohms), BNC (75 Ohms)
Line Rate:
2.048 Mbps, ±50 bps (±200 bps VCO lock range).
Frame Relay Interface
Meets ANSI T1.618, two-octet header.
Number of Frame Relay Interfaces
1-31 occupied channels where 1 <= n <= 31, and the sum of all
n <= 31
Frame Relay Interface Rate
Either 56 Kbps or n x 64 Kbps, where 1 <= n <= 31. Sum of all
n <= 31.
Line Code:
Bipolar AMI or HDB3.
Line Impedance:
120 ohms (balanced) or 75 ohms, balanced or unbalanced.
Minimum Pulse Density:
Zero code suppression via HDB3 coding.
Frame Format:
Unframed, 32-channel (G.703). Framed: 30 or 31-channel CEPT multiframe per ITU-T G.704.
VF Signalling:
CAS or CCS.
Max. Line Lengths:
E1 output complies with G.703, so cabling must not exceed -6dB/1000 feet at 1024 kHz (applies to 75 ohm coax or 120 ohm twisted pair up to 350 meters or 1000 feet).
IGX synchronizes to the nearest, highest-stratum clock available. Any E1 or T1 circuit line, trunk, or optional external clock input can be used as a clock source.
StrataView Plus workstation and StrataCom software required for graphical display of network status, statistics gathering and display, and automatic downloading of software.
Control Terminal:
DEC VT100, WYSE 85, Televideo 970 or equivalent terminal for basic system configuring and alarm monitoring.
Remote Alarm Reporting:
Auto-dial modem connects to one of two control ports on each IGX node for automatic reporting of network alarms.
Remote Diagnostics:
Auto-answer modem connects to one of two control ports on each IGX node for remote diagnostic access by StrataCom ISC or other authorized personnel.
Network Control Ports:
Two ports per node, (one RS 232C interface and one Ethernet LAN port).
Alarm Notification:
Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to StrataView Plus workstation at connecting node.
External Alarms:
Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements when equipped with DTI group.
Indicators and Controls:
Active and Fail lights on all cards and power supplies.