Cisco ONS 15454 Series Multiservice Provisioning Platforms

Field Notice: *Expired* FN - 12023 - Timing Offset Increases Bit Errors on OC12 Cards


Revised July 10, 2007

April 12, 2000

NOTICE:

THIS FIELD NOTICE HAS BEEN ARCHIVED AND IS NO LONGER MAINTAINED OR UPDATED BY CISCO.

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE, WARRANTY OR SUPPORT. USE OF THE INFORMATION ON THIS FIELD NOTICE OR MATERIALS LINKED FROM THIS FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.


Products Affected

Product

TAN

TAN Rev

Comments

HW Rev

15454-OC121LR1310

800-06759-01

-A0

^ASY,ELMECH,OC12,LR,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121LR1550

800-06760-01

-A0

^ASY,ELMECH,OC12,LR,1550,1 CKT,SC

P05A-P05B, 005B

15454-OC121IR1310

800-06758-01

-A0

^ASY,ELMECH,OC12,1R,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121LR1310

800-06759-01

-A0

^ASY,ELMECH,OC12,LR,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121LR1550

800-06760-01

-A0

^ASY,ELMECH,OC12,LR,1550,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121IR1310

800-06758-01

-A0

^ASY,ELMECH,OC12,1R,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121IR1310=

800-06758-01

-A0

^ASY,ELMECH,OC12,1R,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121LR1310

800-06759-01

-A0

^ASY,ELMECH,OC12,LR,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121LR1310=

800-06759-01

-A0

^ASY,ELMECH,OC12,LR,1310,1 CKT,SC

P05A - P05H, 005H-005M

15454-OC121LR1550

800-06760-01

-A0

^ASY,ELMECH,OC12,LR,1550,1 CKT,SC

P05A-P05B, 005B

15454-OC121LR1550=

800-06760-01

-A0

^ASY,ELMECH,OC12,LR,1550,1 CKT,SC

P05A-P05B, 005B

15454-OC121IR1310

800-06758-01

-A0

^ASY,ELMECH,OC12,1R,1310,1 CKT,SC

P05A - P05H, 005H-005M

Problem Description

Bit errors may be seen on an OC-12 card when the incoming line frequency is less than the internal clock of the Network Element (NE) by more than four parts per million (ppm). This can happen as a result of synchronization problems in the network, or if the node is operating in free running synchronous mode.

Background

This problem was discovered in the field and verified during subsequent lab evaluations.

Problem Symptoms

Bit errors may be seen when synchronization timing references drift off frequency by four or more ppm, or when networks are configured to free running synchronous mode.

Workaround/Solution

The problem has been corrected in the current release of OC-12 cards (Part # 800-06758-02, 800-06759-02, 800-06760-02) and all later versions.

OC-12 cards with the Cisco part numbers listed in the following table are susceptible to this condition.

Part Name

Cisco Part Number

Cisco Rev

Cerent Part Number

Cerent Rev

15454-OC12 1 IR 1310

800-06758-01

A0

87-31-00003

P05A - P05H, 005H - 005M

15454-OC12 1 LR 1310

800-06759-01

A0

87-31-00009

P05A - P05H, 005H - 005M

15454-OC12 1 LR 1550

800-06760-01

A0

87-31-00022

P05A - P05B, 005B

If you have these cards deployed in your network and suspect increased bit errors as a result of the problem symptoms outlined above, please call the Cisco Technical Assistance Center (TAC) to request a Return Material Authorization (RMA). All revisions of our OC-12 cards later than the versions outlined above have incorporated design improvements to account for increased frequency offsets.

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods: