Performing a Link Test

Performing a Link Test (GUI)

Procedure


Step 1

Choose Monitor > Clients to open the Clients page.

Step 2

Hover your cursor over the blue drop-down arrow for the desired client and choose LinkTest. A link test page appears.

Note 

You can also access this page by clicking the MAC address of the desired client and then clicking the Link Test button on the top of the Clients > Detail page.

This page shows the results of the CCX link test.

Note 

If the client and/or controller does not support CCX v4 or later releases, the controller performs a ping link test on the client instead, and a much more limited link test page appears.

Note 

The Link Test results of CCX clients when it fails will default to ping test results if the client is reachable.

Step 3

Click OK to exit the link test page.


Performing a Link Test (CLI)

Use these commands to run a link test using the controller CLI:

  • Run a link test by entering this command:

    linktest ap_mac

    When CCX v4 or later releases is enabled on both the controller and the client being tested, information similar to the following appears:

    
    CCX Link Test to 00:0d:88:c5:8a:d1.
         Link Test Packets Sent...................................... 20
         Link Test Packets Received................................. 10
         Link Test Packets Lost (Total/AP to Client/Client to AP).... 10/5/5
         Link Test Packets round trip time (min/max/average)......... 5ms/20ms/15ms
         RSSI at AP (min/max/average)................................ -60dBm/-50dBm/-55dBm
         RSSI at Client (min/max/average)............................ -50dBm/-40dBm/-45dBm
         SNR at AP (min/max/average)................................. 40dB/30dB/35dB
         SNR at Client (min/max/average)............................. 40dB/30dB/35dB
         Transmit Retries at AP (Total/Maximum)...................... 5/3
         Transmit Retries at Client (Total/Maximum).................. 4/2
         Transmit rate:  1M   2M   5.5M   6M   9M  11M 12M 18M   24M   36M  48M  54M  108M
         Packet Count:   0     0     0    0    0    0   0   0     0     2    0   18     0
         Transmit rate:  1M   2M   5.5M   6M   9M  11M 12M 18M   24M   36M  48M  54M  108M
         Packet Count:   0     0     0    0    0    0   0   0     0     2    0    8     0
    
    

    When CCX v4 or later releases is not enabled on either the controller or the client being tested, fewer details appear:

    
    Ping Link Test to 00:0d:88:c5:8a:d1.
            Link Test Packets Sent.......................... 20
            Link Test Packets Received...................... 20
            Local Signal Strength........................... -49dBm
            Local Signal to Noise Ratio..................... 39dB
    
    
  • Adjust the link-test parameters that are applicable to both the CCX link test and the ping test by entering these commands from configuration mode:

    linktest frame-size size_of_link-test_frames

    linktest num-of-frame number_of_link-test_request_frames_per_test