Understanding Interface Types
This section describes the different types of interfaces supported by the switch with references to chapters that contain more detailed information about configuring these interface types.
Port-Based VLANs
A VLAN is a switched network that is logically segmented by function, team, or application, without regard to the physical location of the users. For more information about VLANs, see the Chapter17, “Configuring VLANs” Packets received on a port are forwarded only to ports that belong to the same VLAN as the receiving port. Network devices in different VLANs cannot communicate with one another without a Layer 3 device to route traffic between the VLANs.
VLAN partitions provide hard firewalls for traffic in the VLAN, and each VLAN has its own MAC address table. A VLAN comes into existence when a local port is configured to be associated with the VLAN, when the VLAN Trunking Protocol (VTP) learns of its existence from a neighbor on a trunk, or when a user creates a VLAN.
To configure VLANs, use the
vlan
vlan-id
global configuration command to enter VLAN configuration mode. The VLAN configurations for normal-range VLANs (VLAN IDs 1 to 1005) are saved in the VLAN database. If VTP is version 1 or 2, to configure extended-range VLANs (VLAN IDs 1006 to 4094), you must first set VTP mode to transparent. Extended-range VLANs created in transparent mode are not added to the VLAN database but are saved in the switch running configuration. With VTP version 3, you can create extended-range VLANs in client or server mode. These VLANs are saved in the VLAN database.
Add ports to a VLAN by using the
switchport
interface configuration commands:
-
Identify the interface.
-
For a trunk port, set trunk characteristics, and if desired, define the VLANs to which it can belong.
-
For an access port, set and define the VLAN to which it belongs.
-
For a tunnel port, set and define the VLAN ID for the customer-specific VLAN tag. See Chapter21, “Configuring IEEE 802.1Q and Layer 2 Protocol Tunneling”
Switch Ports
Switch ports are Layer 2-only interfaces associated with a physical port. A switch port can be an access port, a trunk port, or a tunnel port. You can configure a port as an access port or trunk port or let the Dynamic Trunking Protocol (DTP) operate on a per-port basis to set the switchport mode by negotiating with the port on the other end of the link. You must manually configure tunnel ports as part of an asymmetric link connected to an IEEE 802.1Q trunk port. Switch ports are used for managing the physical interface and associated Layer 2 protocols.
Configure switch ports by using the
switchport
interface configuration commands. Use the
switchport
command with no keywords to put an interface that is in Layer 3 mode into Layer 2 mode.
Note When you put an interface that is in Layer 3 mode into Layer 2 mode, the previous configuration information related to the affected interface might be lost, and the interface is returned to its default configuration.
For detailed information about configuring access port and trunk port characteristics, see Chapter17, “Configuring VLANs” For more information about tunnel ports, see Chapter 17, “Configuring IEEE 802.1Q and Layer 2 Protocol Tunneling.”
Access Ports
An access port belongs to and carries the traffic of only one VLAN (unless it is configured as a voice VLAN port). Traffic is received and sent in native formats with no VLAN tagging. Traffic arriving on an access port is assumed to belong to the VLAN assigned to the port.
If an access port receives an 802.1Q tagged packet, the packet is dropped, and the source address is not learned.
Two types of access ports are supported:
-
Static access ports are manually assigned to a VLAN (or through a RADIUS server for use with IEEE 802.1x. For more information, see the “802.1x Authentication with VLAN Assignment” section.
-
VLAN membership of dynamic access ports is learned through incoming packets. By default, a dynamic access port is not a member of any VLAN, and forwarding to and from the port is enabled only when the VLAN membership of the port is discovered. Dynamic access ports on the switch are assigned to a VLAN by a VLAN Membership Policy Server (VMPS). The VMPS can be a Catalyst 6500 series switch; the IE 3000 switch cannot be a VMPS server.
You can also configure an access port with an attached Cisco IP Phone to use one VLAN for voice traffic and another VLAN for data traffic from a device attached to the phone. For more information about voice VLAN ports, see Chapter19, “Configuring Voice VLAN”
Trunk Ports
A trunk port carries the traffic of multiple VLANs and by default is a member of all VLANs in the VLAN database.
The switch supports only IEEE 802.1Q trunk ports. An IEEE 802.1Q trunk port supports simultaneous tagged and untagged traffic. An IEEE 802.1Q trunk port is assigned a default port VLAN ID (PVID), and all untagged traffic travels on the port default PVID. All untagged traffic and tagged traffic with a NULL VLAN ID are assumed to belong to the port default PVID. A packet with a VLAN ID equal to the outgoing port default PVID is sent untagged. All other traffic is sent with a VLAN tag.
Although by default, a trunk port is a member of every VLAN known to the VTP, you can limit VLAN membership by configuring an allowed list of VLANs for each trunk port. The list of allowed VLANs does not affect any other port but the associated trunk port. By default, all possible VLANs (VLAN ID 1 to 4094) are in the allowed list. A trunk port can become a member of a VLAN only if VTP knows of the VLAN and if the VLAN is in the enabled state. If VTP learns of a new, enabled VLAN and the VLAN is in the allowed list for a trunk port, the trunk port automatically becomes a member of that VLAN and traffic is forwarded to and from the trunk port for that VLAN. If VTP learns of a new, enabled VLAN that is not in the allowed list for a trunk port, the port does not become a member of the VLAN, and no traffic for the VLAN is forwarded to or from the port.
For more information about trunk ports, see Chapter17, “Configuring VLANs”
Tunnel Ports
Tunnel ports are used in IEEE 802.1Q tunneling to segregate the traffic of customers in a service-provider network from other customers who are using the same VLAN number. You configure an asymmetric link from a tunnel port on a service-provider edge switch to an IEEE 802.1Q trunk port on the customer switch. Packets entering the tunnel port on the edge switch, already IEEE 802.1Q-tagged with the customer VLANs, are encapsulated with another layer of an IEEE 802.1Q tag (called the metro tag), containing a VLAN ID unique in the service-provider network, for each customer. The double-tagged packets go through the service-provider network keeping the original customer VLANs separate from those of other customers. At the outbound interface, also a tunnel port, the metro tag is removed, and the original VLAN numbers from the customer network are retrieved.
Note Tunnel ports are supported only on switches running the IP services image.
Tunnel ports cannot be trunk ports or access ports and must belong to a VLAN unique to each customer.
For more information about tunnel ports, see Chapter21, “Configuring IEEE 802.1Q and Layer 2 Protocol Tunneling”
Routed Ports
A routed port is a physical port that acts like a port on a router; it does not have to be connected to a router. A routed port is not associated with a particular VLAN, as is an access port. A routed port behaves like a regular router interface, except that it does not support VLAN subinterfaces. Routed ports can be configured with a Layer 3 routing protocol. A routed port is a Layer 3 interface only and does not support Layer 2 protocols, such as DTP and STP. Routed ports are supported only on switches running the IP base or IP services image.
Configure routed ports by putting the interface into Layer 3 mode with the
no switchport
interface configuration command. Then assign an IP address to the port, enable routing, and assign routing protocol characteristics by using the ip routing and router
protocol
global configuration
commands.
Note Entering a no switchport interface configuration command shuts down the interface and then re-enables it, which might generate messages on the device to which the interface is connected. When you put an interface that is in Layer 2 mode into Layer 3 mode, the previous configuration information related to the affected interface might be lost.
The number of routed ports that you can configure is not limited by software. However, the interrelationship between this number and the number of other features being configured might impact CPU performance because of hardware limitations. See the “Configuring Layer 3 Interfaces” section for information about what happens when hardware resource limitations are reached.
For more information about IP unicast and multicast routing and routing protocols, see Chapter 41, “Configuring IP Unicast Routing” and the
“IP Multicast Routing Configuration Guide, Cisco IOS Release 15.2(2)E (Industrial Ethernet 3000 Switch)”
Note The IP base image supports static routing and the Routing Information Protocol (RIP). For full Layer 3 routing or for fallback bridging, you must have the IP services image installed.
Switch Virtual Interfaces
A switch virtual interface (SVI) represents a VLAN of switch ports as one interface to the routing or bridging function in the system. Only one SVI can be associated with a VLAN, but you need to configure an SVI for a VLAN only when you wish to route between VLANs, to fallback-bridge nonroutable protocols between VLANs, or to provide IP host connectivity to the switch.
Note SVIs are supported only on switches running the IP services image.
By default, an SVI is created for the default VLAN (VLAN 1) to permit remote switch administration. Additional SVIs must be explicitly configured.
Note You cannot delete interface VLAN 1.
SVIs provide IP host connectivity only to the system; in Layer 3 mode, you can configure routing across SVIs.
Although the switch supports a total or 1005 VLANs (and SVIs), the interrelationship between the number of SVIs and routed ports and the number of other features being configured might impact CPU performance because of hardware limitations. See the “Configuring Layer 3 Interfaces” section for information about what happens when hardware resource limitations are reached.
SVIs are created the first time that you enter the vlan interface configuration command for a VLAN interface. The VLAN corresponds to the VLAN tag associated with data frames on an ISL or IEEE 802.1Q encapsulated trunk or the VLAN ID configured for an access port. Configure a VLAN interface for each VLAN for which you want to route traffic, and assign it an IP address. For more information, see the “Manually Assigning IP Information” section.
Note When you create an SVI, it does not become active until it is associated with a physical port.
SVIs support routing protocols and bridging configurations. For more information about configuring IP routing, see “Configuring IP Unicast Routing,” Chapter 50, “Configuring Fallback Bridging” and the
“IP Multicast Routing Configuration Guide, Cisco IOS Release 15.2(2)E (Industrial Ethernet 3000 Switch)”
Note The IP base image supports static routing and RIP; for more advanced routing or for fallback bridging, you must have the IP services image installed.
SVI Autostate Exclude
The line state of an SVI with multiple ports on a VLAN is in the
up
state when it meets these conditions:
-
The VLAN exists and is active in the VLAN database on the switch.
-
The VLAN interface exists and is not administratively down.
-
At least one Layer 2 (access or trunk) port exists, has a link in the
up
state on this VLAN, and is in the spanning-tree forwarding state on the VLAN.
Note The protocol link state for VLAN interfaces come up when the first switchport belonging to the corresponding VLAN link comes up and is in STP forwarding state.
The default action, when a VLAN has multiple ports, is that the SVI goes down when all ports in the VLAN go down. You can use the SVI autostate exclude feature to configure a port so that it is not included in the SVI line-state up-an- down calculation. For example, if the only active port on the VLAN is a monitoring port, you might configure autostate exclude on that port so that the VLAN goes down when all other ports go down. When enabled on a port,
autostate exclude
applies to all VLANs that are enabled on that port.
The VLAN interface is brought up when one Layer 2 port in the VLAN has had time to converge (transition from STP listening-learning state to forwarding state). This prevents features such as routing protocols from using the VLAN interface as if it were fully operational and minimizes other problems, such as routing black holes. For information about configuring autostate exclude, see the “Configuring SVI Autostate Exclude” section.
EtherChannel Port Groups
EtherChannel port groups treat multiple switch ports as one switch port. These port groups act as a single logical port for high-bandwidth connections between switches or between switches and servers. An EtherChannel balances the traffic load across the links in the channel. If a link within the EtherChannel fails, traffic previously carried over the failed link changes to the remaining links. You can group multiple trunk ports into one logical trunk port, group multiple access ports into one logical access port, group multiple tunnel ports into one logical tunnel port, or group multiple routed ports into one logical routed port.
Most protocols operate over either single ports or aggregated switch ports and do not recognize the physical ports within the port group. Exceptions are the DTP, the Cisco Discovery Protocol (CDP), and the Port Aggregation Protocol (PAgP), which operate only on physical ports.
When you configure an EtherChannel, you create a port-channel logical interface and assign an interface to the EtherChannel. Use the
channel-group
interface configuration command to dynamically create the port-channel logical interface. This command binds the physical and logical ports together.
For Layer 3 interfaces, you manually create the logical interface by using the
interface port-channel
global configuration command. Then you manually assign an interface to the EtherChannel by using the
channel-group
interface configuration command.
For more information, see Chapter40, “Configuring EtherChannels and Link-State Tracking”
Dual-Purpose Uplink Ports
Some switches support dual-purpose uplink ports. Each uplink port is considered as a single interface with dual front ends—an RJ-45 connector and a small form-factor pluggable (SFP) module connector. The dual front ends are not redundant interfaces, and the switch activates only one connector of the pair.
By default, the switch dynamically selects the interface type that first links up. However, you can use the
media-type
interface configuration command to manually select the RJ-45 connector or the SFP module connector. For information about configuring speed and duplex settings for a dual-purpose uplink, see the “Setting the Interface Speed and Duplex Parameters” section.
Each uplink port has two LEDs: one shows the status of the RJ-45 port, and one shows the status of the SFP module port. The port LED is on for whichever connector is active. For more information about the LEDs, see the hardware installation guide.
Connecting Interfaces
Devices within a single VLAN can communicate directly through any switch. Ports in different VLANs cannot exchange data without going through a routing device.
With a standard Layer 2 switch, ports in different VLANs have to exchange information through a router. By using the switch with routing enabled, when you configure both VLAN 20 and VLAN 30 with an SVI to which an IP address is assigned, packets can be sent from Host A to Host B directly through the switch with no need for an external router (Figure 15-1).
Figure 15-1 Connecting VLANs with a Layer 3 Switch
With the IP services image, the switch supports two methods of forwarding traffic between interfaces: routing and fallback bridging. With the IP base image, only basic routing (static routing and RIP) is supported. Whenever possible, to maintain high performance, forwarding is done by the switch hardware. However, only IP Version 4 packets with Ethernet II encapsulation can be routed in hardware. Non-IP traffic and traffic with other encapsulation methods can be fallback-bridged by hardware.
Using Interface Configuration Mode
The switch supports these interface types:
-
Physical ports—switch ports and routed ports
-
VLANs—switch virtual interfaces
-
Port channels—EtherChannel interfaces
You can also configure a range of interfaces (see the “Configuring a Range of Interfaces” section).
To configure a physical interface (port), specify the interface type, module number, and switch port number, and enter interface configuration mode.
-
Type
—Port types depend on those supported on the switch. Possible types are:
Fast Ethernet (fastethernet or fa) for 10/100 Mb/s Ethernet, Gigabit Ethernet (gigabitethernet or gi) for 10/100/1000 Mb/s Ethernet ports, 10-Gigabit Ethernet (tengigabitethernet or te) for 10,000 Mb/s, or small form-factor pluggable (SFP) module Gigabit Ethernet interfaces.
-
Module number
—
The module number on the switch. The module number (1 to 3) depends on how the module is connected to the switch or to other modules.
–
The module number for the IE-3000-4TC and IE-3000-8TC switches is 1.
–
The module number for a module that is directly connected to the switch is 2.
–
The module number for a module that is connected to another module is 3
.
-
Port number—The physical interface number on the switch. The port numbers for the IE-3000-4TC switch model are 1–4 for the Fast Ethernet ports and 1–2 for the Gigabit Ethernet ports. The port numbers for the IE-3000-8TC switch model are 1–8 for the Fast Ethernet ports and 1–2 for the Gigabit Ethernet ports.
Table 15-1
shows the switch and module combinations and the interface numbers.
Table 15-1 Switch Interface Numbers
|
|
Interface Numbering Scheme
|
IE-3000-4TC switch
|
1
|
Fast Ethernet1/1, Fast Ethernet1/2, Fast Ethernet1/3, Fast Ethernet1/4, Gigabit Ethernet1/1, and Gigabit Ethernet1/2
|
IE-3000-8TC switch
|
1
|
Fast Ethernet1/1, Fast Ethernet1/2, Fast Ethernet1/3, Fast Ethernet1/4, Fast Ethernet1/5, Fast Ethernet1/6, Fast Ethernet1/7, Fast Ethernet1/8, Gigabit Ethernet1/1, and Gigabit Ethernet1/2
|
IEM-3000-8TM expansion module
(connected to the switch)
|
2
|
Fast Ethernet2/1, Fast Ethernet2/2, Fast Ethernet2/3, Fast Ethernet2/4, Fast Ethernet2/5, Fast Ethernet2/6, Fast Ethernet2/7, and Fast Ethernet2/8
|
IEM-3000-8TM expansion module
(connected to another module)
|
3
|
Fast Ethernet3/1, Fast Ethernet3/2, Fast Ethernet3/3, Fast Ethernet3/4, Fast Ethernet3/5, Fast Ethernet3/6, Fast Ethernet3/7, and Fast Ethernet3/8
|
You can identify physical interfaces by looking at the switch. You can also use the
show
privileged EXEC commands to display information about a specific interface or all the interfaces. The remainder of this chapter primarily provides physical interface configuration procedures.
Procedures for Configuring Interfaces
These general instructions apply to all interface configuration processes.
Step 1
Enter the
configure terminal
command at the privileged EXEC prompt:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z.
Step 2
Enter the
interface
global configuration command.
Identify the interface type and the interface number, Gigabit Ethernet port 1 in this example:
Switch(config)# interface gigabitethernet1/1
Note Entering a space between the interface type and interface number is optional
Step 3
Follow each
interface
command with the configuration commands that the interface requires. The commands that you enter define the protocols and applications that will run on the interface. The commands are collected and applied to the interface when you enter another interface command or enter
end
to return to privileged EXEC mode.
You can also configure a range of interfaces by using the
interface range
or
interface range macro
global configuration commands. Interfaces configured in a range must be the same type and must be configured with the same feature options.
Step 4
After you configure an interface, verify its status by using the
show
privileged EXEC commands listed
in the “Monitoring and Maintaining the Interfaces” section.
Enter the
show interfaces
privileged EXEC command to see a list of all interfaces on or configured for the switch. A report is provided for each interface that the device supports or for the specified interface.
Configuring a Range of Interfaces
You can use the
interface range
global configuration command to configure multiple interfaces with the same configuration parameters. When you enter the interface-range configuration mode, all command parameters that you enter are attributed to all interfaces within that range until you exit this mode.
Beginning in privileged EXEC mode, follow these steps to configure a range of interfaces with the same parameters:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface range
{
port-range
|
macro
macro_name
}
|
Specify the range of interfaces (VLANs or physical ports) to be configured, and enter interface-range configuration mode.
-
You can use the
interface range
command to configure up to five port ranges or a previously defined macro.
-
The
macro
variable is explained in the “Configuring and Using Interface Range Macros” section.
-
In a comma-separated
port-range
, you must enter the interface type for each entry and enter spaces before and after the comma.
-
In a hyphen-separated
port-range
, you do not need to re-enter the interface type, but you must enter a space before the hyphen.
|
Step 3
|
|
Use the normal configuration commands to apply the configuration parameters to all interfaces in the range. Each command is executed as it is entered.
|
Step 4
|
end
|
Return to privileged EXEC mode.
|
Step 5
|
show interfaces
[
interface-id
]
|
Verify the configuration of the interfaces in the range.
|
Step 6
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
When using the
interface range
global configuration command, note these guidelines:
-
Valid entries for
port-range,
depending on port types on the switch:
–
vlan
vlan-ID
-
vlan-ID
, where the VLAN ID is 1 to 4094
–
, where the module is always 0
–
fastethernet
module/{first
port
} - {
last port
}, where the module is always 0
–
gigabitethernet
module/{
first port
} - {
last port
}, where the module is always 0
–
port-channel
port-channel-number
-
port-channel-number
, where the
port-channel-number
is 1 to 6
Note When you use the interface range command with port channels, the first and last port-channel number must be active port channels.
-
You must add a space between the first interface number and the hyphen when using the interface range command.
For example, interface range
gigabitethernet1/1 - 2
is a valid range; interface range
gigabit
ethernet
1/1-2
is not.
-
The
interface range
command only works with VLAN interfaces that have been configured with the
interface vlan
command. The
show running-config
privileged EXEC command displays the configured VLAN interfaces. VLAN interfaces not displayed by the
show running-config
command cannot be used with the
interface range
command.
-
All interfaces defined in a range must be the same type (all Fast Ethernet ports, all Gigabit Ethernet ports, all EtherChannel ports, or all VLANs), but you can enter multiple ranges in a command.
This example shows how to use the
interface range
global configuration command to set the speed on ports 1 to 2 to 100 Mb/s:
Switch# configure terminal Switch(config)# interface range gigabitethernet1/1 - 2 Switch(config-if-range)# speed 100
This example shows how to use a comma to add different interface type strings to the range to enable Fast Ethernet ports 1 to 3 and Gigabit Ethernet ports 1 and 2 to receive flow-control pause frames:
Switch# configure terminal SSwitch(config)# interface range fastethernet1/1 - 3, gigabitethernet1/1 - 2 Switch(config-if-range)# flowcontrol receive on
If you enter multiple configuration commands while you are in interface-range mode, each command is executed as it is entered. The commands are not batched and executed after you exit interface-range mode. If you exit interface-range configuration mode while the commands are being executed, some commands might not be executed on all interfaces in the range. Wait until the command prompt reappears before exiting interface-range configuration mode.
Configuring and Using Interface Range Macros
You can create an interface range macro to automatically select a range of interfaces for configuration. Before you can use the macro keyword in the interface range macro global configuration command string, you must use the
define interface-range
global configuration command to define the macro.
Beginning in privileged EXEC mode, follow these steps to define an interface range macro:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
define interface-range
macro_name
interface-range
|
Define the interface-range macro, and save it in NVRAM.
-
The
macro_name
is a 32-character maximum character string.
-
A macro can contain up to five comma-separated interface ranges.
-
Each
interface-range
must consist of the same port type.
|
Step 3
|
interface range macro
macro_name
|
Select the interface range to be configured using the values saved in the interface-range macro called
macro_name.
You can now use the normal configuration commands to apply the configuration to all interfaces in the defined macro.
|
Step 4
|
end
|
Return to privileged EXEC mode.
|
Step 5
|
show running-config | include define
|
Show the defined interface range macro configuration.
|
Step 6
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
Use the
no define interface-range
macro_name
global configuration command to delete a macro.
When using the
define
interface-range
global configuration command, note these guidelines:
-
Valid entries for
interface-range,
depending on port types on the switch:
–
vlan
vlan-ID
-
vlan-ID
, where the VLAN ID is 1 to 4094
–
fastethernet
module/{first
port
} - {
last port
}, where the module is always 0
–
gigabitethernet
module/{
first port
} - {
last port
}, where the module is always 0
–
port-channel
port-channel-number
-
port-channel-number
, where the
port-channel-number
is 1 to 6
Note When you use the interface range command with port channels, the first and last port-channel number must be active port channels.
-
You must add a space between the first interface number and the hyphen when entering an
interface-rang
.
For example,
gigabitethernet1/1 - 2
is a valid range;
gigabit
ethernet
1/1-2
is not.
-
The VLAN interfaces must have been configured with the
interface vlan
command. The
show running-config
privileged EXEC command displays the configured VLAN interfaces. VLAN interfaces not displayed by the
show running-config
command cannot be used as
interface-ranges
.
-
All interfaces defined as in a range must be the same type (all Fast Ethernet ports, all Gigabit Ethernet ports, all EtherChannel ports, or all VLANs), but you can combine multiple interface types in a macro.
This example shows how to define an interface-range named
enet_list
to include ports 1 and 2 and to verify the macro configuration:
Switch# configure terminal Switch(config)# define interface-range enet_list gigabitethernet1/1 - 2 Switch# show running-config | include define Switch# define interface-range enet_list gigabitethernet1/1 - 2
This example shows how to create a multiple-interface macro named
macro1
:
Switch# configure terminal Switch(config)# define interface-range macro1 fastethernet1/1 - 2, gigabitethernet1/1 - 2
This example shows how to enter interface-range configuration mode for the interface-range macro
enet_list
:
Switch# configure terminal Switch(config)# interface range macro enet_list
This example shows how to delete the interface-range macro
enet_list
and to verify that it was deleted.
Switch# configure terminal Switch(config)# no define interface-range enet_list Switch# show run | include define
Configuring Ethernet Interfaces
These sections contain this configuration information:
Default Ethernet Interface Configuration
Table 15-2
shows the Ethernet interface default configuration. For more details on the VLAN parameters listed in the table, see Chapter17, “Configuring VLANs” For details on controlling traffic to the port, see Chapter29, “Configuring Port-Based Traffic Control”
Note To configure Layer 2 parameters, if the interface is in Layer 3 mode, you must enter the switchport interface configuration command without any parameters to put the interface into Layer 2 mode. This shuts down the interface and then re-enables it, which might generate messages on the device to which the interface is connected. When you put an interface that is in Layer 3 mode into Layer 2 mode, the previous configuration information related to the affected interface might be lost, and the interface is returned to its default configuration.
Table 15-2 Default Layer 2 Ethernet Interface Configuration
|
|
Operating mode
|
Layer 2 or
switching mode
(
switchport
command).
|
Allowed VLAN range
|
VLANs 1 to 4094.
|
Default VLAN (for access ports)
|
VLAN 1 (Layer 2 interfaces only).
|
Native VLAN (for IEEE 802.1Q trunks)
|
VLAN 1 (Layer 2 interfaces only).
|
VLAN trunking
|
Switchport mode dynamic auto (supports DTP) (Layer 2 interfaces only).
|
Port enable state
|
All ports are enabled.
|
Port description
|
None defined.
|
Speed
|
Autonegotiate.
|
Duplex mode
|
Autonegotiate.
|
Flow control
|
Flow control is set to
receive
:
off
. It is always off for sent packets.
|
EtherChannel (PAgP)
|
Disabled on all Ethernet ports. Chapter40, “Configuring EtherChannels and Link-State Tracking”
|
Port blocking (unknown multicast and unknown unicast traffic)
|
Disabled (not blocked) (Layer 2 interfaces only). See the “Configuring Port Blocking” section.
|
Broadcast, multicast, and unicast storm control
|
Disabled. See the “Default Storm Control Configuration” section.
|
Protected port
|
Disabled (Layer 2 interfaces only). See the “Configuring Protected Ports” section.
|
Port security
|
Disabled (Layer 2 interfaces only). See the “Default Port Security Configuration” section.
|
Port Fast
|
Disabled. See the “Default Optional Spanning-Tree Configuration” section.
|
Auto-MDIX
|
Enabled.
Note The switch might not support a pre-standard powered device—such as Cisco IP phones and access points that do not fully support IEEE 802.3af—if that powered device is connected to the switch through a crossover cable. This is regardless of whether auto-MIDX is enabled on the switch port. |
Keepalive messages
|
Disabled on SFP module ports; enabled on all other ports.
|
Setting the Type of a Dual-Purpose Uplink Port
Some switches support dual-purpose uplink ports. By default, the switch dynamically selects the interface type that first links up. However, you can use the
media-type
interface configuration command to manually select the RJ-45 connector or the SFP module connector. For more information, see the “Dual-Purpose Uplink Ports” section.
Beginning in privileged EXEC mode, follow these steps to select which dual-purpose uplink to activate so that you can set the speed and duplex. This procedure is optional.
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
interface-id
|
Specify the dual-purpose uplink port to be configured, and enter interface configuration mode.
|
Step 3
|
media-type
{
auto-select
|
rj45
|
sfp
}
|
Select the interface and type of a dual-purpose uplink port. The keywords have these meanings:
-
auto-select
—
The switch dynamically selects the type. When link up is achieved, the switch disables the other type until the active link goes down. When the active link goes down, the switch enables both types until one of them links up. In auto-select mode, the switch configures both types with autonegotiation of speed and duplex (the default). Depending on the type of installed SFP module, the switch might not be able to dynamically select it. For more information, see the information that follows this procedure.
-
rj45
—
The switch disables the SFP module interface. If you connect an SFP module to this port, it cannot attain a link even if the RJ-45 side is down or is not connected. In this mode, the dual-purpose port behaves like a 10/100/1000BASE-TX interface. You can configure the speed and duplex settings consistent with this interface type.
-
sfp
—
The switch disables the RJ-45 interface. If you connect a cable to the RJ-45 port, it cannot attain a link even if the SFP module side is down or if the SFP module is not present. Based on the type of installed SFP module, you can configure the speed and duplex settings consistent with this interface type.
For information about setting the speed and duplex, see the “Speed and Duplex Configuration Guidelines” section.
|
Step 4
|
end
|
Return to privileged EXEC mode.
|
Step 5
|
show interfaces
interface-id
transceiver properties
|
Verify your setting.
|
Step 6
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
To return to the default setting, use the
media-type auto interface
or the
no media-type
interface configuration commands.
e switch configures both types to autonegotiate speed and duplex (the default). If you configure
auto-select
, you cannot configure the
speed
and
duplex
interface configuration commands.
When the switch powers on or when you enable a dual-purpose uplink port through the
shutdown
and the
no shutdown
interface configuration commands, the switch gives preference to the SFP module interface. In all other situations, the switch selects the active link based on which type first links up.
The switch operates with 100BASE-
x
(where -
x
is -BX, -FX-FE, -LX) SFP modules as follows:
-
When the 100BASE -
x
SFP module is inserted into the module slot and there is no link on the RJ-45 side, the switch disables the RJ-45 interface and selects the SFP module interface. This is the behavior even if there is no cable connected and if there is no link on the SFP module side.
-
When the 100BASE-
x
SFP module is inserted and there is a link on the RJ-45 side, the switch continues with that link. If the link goes down, the switch disables the RJ-45 side and selects the SFP module interface.
-
When the 100BASE-
x
SFP module is removed, the switch again dynamically selects the type (
auto-select
) and re-enables the RJ-45 side.
The switch does not have this behavior with 100BASE-FX-GE SFP modules.
Configuring Interface Speed and Duplex Mode
Depending on the supported port types, Ethernet interfaces on the switch operate at 10, 100, or 1000 Mb/s, or 10,000 Mb/s and in either full- or half-duplex mode. In full-duplex mode, two stations can send and receive traffic at the same time. Normally, 10-Mb/s ports operate in half-duplex mode, which means that stations can either receive or send traffic.
Switch models can include combinations of Fast Ethernet (10/100-Mb/s) ports, Gigabit Ethernet (10/100/1000-Mb/s) ports, 10-Gigabit module ports, and small form-factor pluggable (SFP) module slots supporting SFP modules.
These sections describe how to configure the interface speed and duplex mode:
Speed and Duplex Configuration Guidelines
When configuring an interface speed and duplex mode, note these guidelines:
-
Fast Ethernet (10/100-Mb/s) ports support all speed and duplex options.
-
Gigabit Ethernet (10/100/1000-Mb/s) ports support all speed options and all duplex options (auto, half, and full). However, Gigabit Ethernet ports operating at 1000 Mb/s do not support half-duplex mode.
-
For SFP module ports, the speed and duplex CLI options change depending on the SFP module type:
–
The 1000BASE-
x
(where -
x
is -BX, -CWDM, -LX, -SX, and -ZX) SFP module ports support the
nonegotiate
keyword in the
speed
interface configuration command. Duplex options are not supported.
–
The 1000BASE-T SFP module ports support the same speed and duplex options as the 10/100/1000-Mb/s ports.
–
The 100BASE-
x
(where -
x
is -BX, -CWDM, -LX, -SX, and -ZX) SFP module ports support only 100 Mb/s. These modules support full- and half- duplex options but do not support autonegotiation.
For information about which SFP modules are supported on your switch, see the product release notes.
-
If both ends of the line support autonegotiation, we highly recommend the default setting of auto negotiation.
-
If one interface supports autonegotiation and the other end does not, configure duplex and speed on both interfaces; do not use the
auto
setting on the supported side.
-
When STP is enabled and a port is reconfigured, the switch can take up to 30 seconds to check for loops. The port LED is amber while STP reconfigures.
Caution Changing the interface speed and duplex mode configuration might shut down and re-enable the interface during the reconfiguration.
Setting the Interface Speed and Duplex Parameters
Beginning in privileged EXEC mode, follow these steps to set the speed and duplex mode for a physical interface:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
interface-id
|
Specify the physical interface to be configured, and enter interface configuration mode.
|
Step 3
|
speed
{
10 | 100 | 1000 | auto
[
10
|
100
|
1000
]
| nonegotiate
}
|
Enter the appropriate speed parameter for the interface:
-
Enter
10
,
100
, or
1000
to set a specific speed for the interface. The
1000
keyword is available only for 10/100/1000 Mb/s ports.
-
Enter
auto
to enable the interface to autonegotiate speed with the connected device. If you use the
10
,
100
, or the
1000
keywords with the
auto
keyword, the port autonegotiates only at the specified speeds.
-
The
nonegotiate
keyword is available only for SFP module ports. SFP module ports operate only at 1000 Mb/s but can be configured to not negotiate if connected to a device that does not support autonegotiation.
For more information about speed settings, see the “Speed and Duplex Configuration Guidelines” section.
|
Step 4
|
duplex
{
auto | full | half
}
|
Enter the duplex parameter for the interface.
Enable half-duplex mode (for interfaces operating only at 10 or 100 Mb/s). You cannot configure half-duplex mode for interfaces operating at 1000 Mb/s.
For more information about duplex settings, see the “Speed and Duplex Configuration Guidelines” section.
|
Step 5
|
end
|
Return to privileged EXEC mode.
|
Step 6
|
show interfaces
interface-id
|
Display the interface speed and duplex mode configuration.
|
Step 7
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
Use the
no speed
and
no duplex
interface configuration commands to return the interface to the default speed and duplex settings (autonegotiate). To return all interface settings to the defaults, use the
default interface
interface-id
interface configuration command.
This example shows how to set the interface speed to 10 Mb/s and the duplex mode to half on a 10/100 Mb/s port:
Switch# configure terminal Switch(config)# interface fasttethernet1/3 Switch(config-if)# speed 10 Switch(config-if)# duplex half
This example shows how to set the interface speed to 100 Mb/s on a 10/100/1000 Mb/s port:
Switch# configure terminal Switch(config)# interface gigabitethernet1/2 Switch(config-if)# speed 100
Configuring IEEE 802.3x Flow Control
Flow control enables connected Ethernet ports to control traffic rates during congestion by allowing congested nodes to pause link operation at the other end. If one port experiences congestion and cannot receive any more traffic, it notifies the other port by sending a pause frame to stop sending until the condition clears. Upon receipt of a pause frame, the sending device stops sending any data packets, which prevents any loss of data packets during the congestion period.
Note Ports on the switch can receive, but not send, pause frames.
You use the
flowcontrol
interface configuration command to set the interface’s ability to
receive
pause frames to
on
,
off
, or
desired
. The default state is
off
.
When set to
desired
, an interface can operate with an attached device that is required to send flow-control packets or with an attached device that is not required to but can send flow-control packets.
These rules apply to flow control settings on the device:
-
receive on
(or
desired
): The port cannot send pause frames but can operate with an attached device that is required to or can send pause frames; the port can receive pause frames.
-
receive off
: Flow control does not operate in either direction. In case of congestion, no indication is given to the link partner, and no pause frames are sent or received by either device.
Note For details on the command settings and the resulting flow control resolution on local and remote ports, see the flowcontrol interface configuration command in the command reference for this release.
Beginning in privileged EXEC mode, follow these steps to configure flow control on an interface:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
interface-id
|
Specify the physical interface to be configured, and enter interface configuration mode.
|
Step 3
|
flowcontrol
{
receive
} {
on
|
off
|
desired
}
|
Configure the flow control mode for the port.
|
Step 4
|
end
|
Return to privileged EXEC mode.
|
Step 5
|
show interfaces
interface-id
|
Verify the interface flow control settings.
|
Step 6
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
To disable flow control, use the
flowcontrol
receive off
interface configuration command.
This example shows how to turn on flow control on a port:
Switch# configure terminal Switch(config)# interface gigabitethernet1/1 Switch(config-if)# flowcontrol receive on
Configuring Auto-MDIX on an Interface
When automatic medium-dependent interface crossover (auto-MDIX) is enabled on an interface, the interface automatically detects the required cable connection type (straight through or crossover) and configures the connection appropriately. When connecting switches without the auto-MDIX feature, you must use straight-through cables to connect to devices such as servers, workstations, or routers and crossover cables to connect to other switches or repeaters. With auto-MDIX enabled, you can use either type of cable to connect to other devices, and the interface automatically corrects for any incorrect cabling. For more information about cabling requirements, see the hardware installation guide.
Auto-MDIX is enabled by default. When you enable auto-MDIX, you must also set the interface speed and duplex to
auto
so that the feature operates correctly.
Auto-MDIX is supported on all 10/100 and 10/100/1000-Mb/s interfaces. It is not supported on 1000BASE-SX or -LX SFP module interfaces.
Table 15-3
shows the link states that result from auto-MDIX settings and correct and incorrect cabling.
Table 15-3 Link Conditions and Auto-MDIX Settings
|
|
|
|
On
|
On
|
Link up
|
Link up
|
On
|
Off
|
Link up
|
Link up
|
Off
|
On
|
Link up
|
Link up
|
Off
|
Off
|
Link up
|
Link down
|
Beginning in privileged EXEC mode, follow these steps to configure auto-MDIX on an interface:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
interface-id
|
Specify the physical interface to be configured, and enter interface configuration mode.
|
Step 3
|
speed auto
|
Configure the interface to autonegotiate speed with the connected device.
|
Step 4
|
duplex auto
|
Configure the interface to autonegotiate duplex mode with the connected device.
|
Step 5
|
mdix auto
|
Enable auto-MDIX on the interface.
|
Step 6
|
end
|
Return to privileged EXEC mode.
|
Step 7
|
show controllers ethernet-controller
interface-id
phy
|
Verify the operational state of the auto-MDIX feature on the interface.
|
Step 8
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
To disable auto-MDIX, use the
no mdix auto
interface configuration command.
This example shows how to enable auto-MDIX on a port:
Switch# configure terminal Switch(config)# interface gigabitethernet1/1 Switch(config-if)# speed auto Switch(config-if)# duplex auto Switch(config-if)# mdix auto
Adding a Description for an Interface
You can add a description about an interface to help you remember its function. The description appears in the output of these privileged EXEC commands:
show configuration
,
show running-config
, and
show interfaces
.
Beginning in privileged EXEC mode, follow these steps to add a description for an interface:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
interface-id
|
Specify the interface for which you are adding a description, and enter interface configuration mode.
|
Step 3
|
description
string
|
Add a description (up to 240 characters) for an interface.
|
Step 4
|
end
|
Return to privileged EXEC mode.
|
Step 5
|
show interfaces
interface-id
description
or
show running-config
|
Verify your entry.
|
Step 6
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
Use the
no description
interface configuration command to delete the description.
This example shows how to add a description on a port and how to verify the description:
Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface gigabitethernet1/2 Switch(config-if)# description Connects to Marketing Switch# show interfaces gigabitethernet1/2 description Interface Status Protocol Description Gi1/2 admin down down Connects to Marketing
Configuring Layer 3 Interfaces
The switch supports these types of Layer 3 interfaces:
-
SVIs: You should configure SVIs for any VLANs for which you want to route traffic. SVIs are created when you enter a VLAN ID following the
interface vlan
global configuration
command. To delete an SVI, use the
no interface vlan
global configuration command. You cannot delete interface VLAN 1.
Note When you create an SVI, it does not become active until it is associated with a physical port. For information about assigning Layer 2 ports to VLANs, see Chapter17, “Configuring VLANs”
When configuring SVIs, you can also configure SVI autostate exclude on a port in the SVI to exclude that port from being included in determining SVI line-state status. See the “Configuring SVI Autostate Exclude” section.
-
Routed ports: Routed ports are physical ports configured to be in Layer 3 mode by using the
no switchport
interface configuration command.
-
Layer 3 EtherChannel ports: EtherChannel interfaces made up of routed ports.
EtherChannel port interfaces are described in Chapter40, “Configuring EtherChannels and Link-State Tracking”
A Layer 3 switch can have an IP address assigned to each routed port and SVI.
There is no defined limit to the number of SVIs and routed ports that can be configured in a switch. However, the interrelationship between the number of SVIs and routed ports and the number of other features being configured might have an impact on CPU usage because of hardware limitations. If the switch is using maximum hardware resources, attempts to create a routed port or SVI have these results:
-
If you try to create a new routed port, the switch generates a message that there are not enough resources to convert the interface to a routed port, and the interface remains as a switchport.
-
If you try to create an extended-range VLAN, an error message is generated, and the extended-range VLAN is rejected.
-
If the switch is notified by VLAN Trunking Protocol (VTP) of a new VLAN, it sends a message that there are not enough hardware resources available and shuts down the VLAN. The output of the
show vlan
user EXEC command shows the VLAN in a suspended state.
-
If the switch attempts to boot up with a configuration that has more VLANs and routed ports than hardware can support, the VLANs are created, but the routed ports are shut down, and the switch sends a message that this was due to insufficient hardware resources.
All Layer 3 interfaces require an IP address to route traffic. This procedure shows how to configure an interface as a Layer 3 interface and how to assign an IP address to an interface.
Note If the physical port is in Layer 2 mode (the default), you must enter the no switchport interface configuration command to put the interface into Layer 3 mode. Entering a no switchport command disables and then re-enables the interface, which might generate messages on the device to which the interface is connected. Furthermore, when you put an interface that is in Layer 2 mode into Layer 3 mode, the previous configuration information related to the affected interface might be lost, and the interface is returned to its default configuration.
Beginning in privileged EXEC mode, follow these steps to configure a Layer 3 interface:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
{{
fastethernet
|
gigabitethernet
}
interface-id
} | {
vlan
vlan-id
} | {
port-channel
port-channel-number
}
|
Specify the interface to be configured as a Layer 3 interface, and enter interface configuration mode.
|
Step 3
|
no switchport
|
For physical ports only, enter Layer 3 mode.
|
Step 4
|
ip address
ip_address subnet_mask
|
Configure the IP address and IP subnet.
|
Step 5
|
no shutdown
|
Enable the interface.
|
Step 6
|
end
|
Return to privileged EXEC mode.
|
Step 7
|
show interfaces
[
interface-id
]
show ip interface
[
interface-id
]
show running-config interface
[
interface-id
]
|
Verify the configuration.
|
Step 8
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
To remove an IP address from an interface, use the
no ip address
interface configuration command.
This example shows how to configure a port as a routed port and to assign it an IP address:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface gigabitethernet1/2 Switch(config-if)# no switchport Switch(config-if)# ip address 192.20.135.21 255.255.255.0 Switch(config-if)# no shutdown
Configuring SVI Autostate Exclude
Configuring SVI autostate exclude on an access or trunk port in an SVI excludes that port in the calculation of the status of the SVI (up or down line state) even if it belongs to the same VLAN. When the excluded port is in the up state, and all other ports in the VLAN are in the down state, the SVI state is changed to down.
At least one port in the VLAN should be up and not excluded to keep the SVI line state up. You can use this command to exclude the monitoring port status when determining the status of the SVI.
Beginning in privileged EXEC mode, follow these steps to exclude a port from SVI state-change calculations:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
interface
interface-id
|
Specify a Layer 2 interface (physical port or port channel), and enter interface configuration mode.
|
Step 3
|
switchport autostate exclude
|
Exclude the access or trunk port when defining the status of an SVI line state (up or down)
|
Step 4
|
end
|
Return to privileged EXEC mode.
|
Step 5
|
show running config interface
interface-id
show interface
interface-id
switchport
|
(Optional) Show the running configuration.
Verify the configuration.
|
Step 6
|
copy running-config startup-config
|
(Optional) Save your entries in the configuration file.
|
This example shows how to configure an access or trunk port in an SVI to be excluded from the status calculation:
Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch(config)# interface gigabitethernet1/2 Switch(config-if)# switchport autostate exclude
Configuring the System MTU
The default maximum transmission unit (MTU) size for frames received and transmitted on all interfaces is 1500 bytes. You can increase the MTU size for all interfaces operating at 10 or 100 Mb/s by using the
system mtu
global configuration command. You can increase the MTU size to support jumbo frames on all Gigabit Ethernet interfaces by using the
system mtu jumbo
global configuration command.
You can change the MTU size for routed ports by using the
system mtu routing
global configuration command.
Note You cannot configure a routing MTU size that exceeds the system MTU size. If you change the system MTU size to a value smaller than the currently configured routing MTU size, the configuration change is accepted, but not applied until the next switch reset. When the configuration change takes effect, the routing MTU size automatically defaults to the new system MTU size.
Gigabit Ethernet ports are not affected by the system mtu command; 10/100 ports are not affected by the system mtu jumbo command. If you d o not configure the
system mtu jumbo
command, the setting of the
system mtu
command applies to all Gigabit Ethernet interfaces.
You cannot set the MTU size for an individual interface; you set it for all 10/100 or all Gigabit Ethernet interfaces. When you change the system or jumbo MTU size, you must reset the switch before the new configuration takes effect.The
system mtu routing
command does not require a switch reset to take effect.
Frames sizes that can be received by the switch CPU are limited to 1998 bytes, no matter what value was entered with the system mtu or system mtu jumbo commands. Although frames that are forwarded or routed are typically not received by the CPU, in some cases packets are sent to the CPU, such as traffic sent to control traffic, SNMP, Telnet, or routing protocols.
Routed packets are subjected to MTU checks on the output ports. The MTU value used for routed ports is derived from the applied
system mtu
value (not the
system mtu jumbo
value). That is, the routed MTU is never greater than the system MTU for any VLAN. The routing protocols use the system MTU value when negotiating adjacencies and the MTU of the link. For example, the Open Shortest Path First (OSPF) protocol uses this MTU value before setting up an adjacency with a peer router. To view the MTU value for routed packets for a specific VLAN, use the
show platform port-asic mvid
privileged EXEC command.
Note If Layer 2 Gigabit Ethernet interfaces are configured to accept frames greater than the 10/100 interfaces, jumbo frames received on a Layer 2 Gigabit Ethernet interface and sent on a Layer 2 10/100 interface are dropped.
Beginning in privileged EXEC mode, follow these steps to change MTU size for all 10/100 or Gigabit Ethernet interfaces:
|
|
|
Step 1
|
configure terminal
|
Enter global configuration mode.
|
Step 2
|
system mtu
bytes
|
(Optional) Change the MTU size for all interfaces on the switch that are operating at 10 or 100 Mb/s.
The range is 1500 to 1998 bytes; the default is 1500 bytes.
|
Step 3
|
system mtu
jumbo
bytes
|
(Optional) Change the MTU size for all Gigabit Ethernet interfaces on the switch.
The range is 1500 to 9000 bytes; the default is 1500 bytes.
|
Step 4
|
system mtu routing
bytes
|
(Optional) Change the system MTU for routed ports. The range is 1500 to the system MTU value, the maximum MTU that can be routed for all ports.
Although larger packets can be accepted, they cannot be routed.
|
Step 5
|
end
|
Return to privileged EXEC mode.
|
Step 6
|
copy running-config startup-config
|
Save your entries in the configuration file.
|
Step 7
|
reload
|
Reload the operating system.
|
If you enter a value that is outside the allowed range for the specific type of interface, the value is not accepted.
Once the switch reloads, you can verify your settings by entering the show system mtu privileged EXEC command.
This example shows how to set the maximum packet size for a Gigabit Ethernet port to 1800 bytes:
Switch(config)# system mtu jumbo 1800
This example shows the response when you try to set Gigabit Ethernet interfaces to an out-of-range number:
Switch(config)# system mtu jumbo 25000 % Invalid input detected at '^' marker.