Support has been added for SNMP MIB to be able to return values from temperature sensors. The output should look similar to
the show environment CLI.
The output of a show environment on an IR1101:
IR1101#show environment
Number of Critical alarms: 0
Number of Major alarms: 0
Number of Minor alarms: 0
Slot Sensor Current State Reading Threshold(Minor,Major,Critical,Shutdown)
---------- -------------- --------------- ------------ ---------------------------------------
R0 Temp: TS1 Normal 42 Celsius (75 ,80 ,90 ,na )(Celsius)
R0 Temp: TS2 Normal 37 Celsius (75 ,80 ,90 ,na )(Celsius)
The output from an snmpwalk would look similar to this:
[root@sg-centos-hv ~]# snmpwalk -v 2c -c public 33.33.33.204 1.3.6.1.4.1.9.9.13.1.3.1
SNMPv2-SMI::enterprises.9.9.13.1.3.1.2.1 = STRING: "Sensor 1"
SNMPv2-SMI::enterprises.9.9.13.1.3.1.3.1 = Gauge32: 48
SNMPv2-SMI::enterprises.9.9.13.1.3.1.4.1 = INTEGER: 93
SNMPv2-SMI::enterprises.9.9.13.1.3.1.5.1 = INTEGER: 0
SNMPv2-SMI::enterprises.9.9.13.1.3.1.6.1 = INTEGER: 1
SNMPv2-SMI::enterprises.9.9.13.1.3.1.7.1 = INTEGER: 0
The ciscoEnvMonTemperatureStatusEntry oid is 1.3.6.1.4.1.9.9.13.1.3.1:
-
ciscoEnvMonTemperatureStatusIndex (.1)
-
ciscoEnvMonTemperatureStatusDescr (.2)
-
ciscoEnvMonTemperatureStatusValue (.3)
-
ciscoEnvMonTemperatureThreshold (.4)
-
ciscoEnvMonTemperatureLastShutdown (.5)
-
ciscoEnvMonTemperatureStatus (.6)