- Read Me First
- Preparing for Broadband Access Aggregation
- Providing Protocol Support for Broadband Access Aggregation of PPPoE Sessions
- PPP for IPv6
- DHCP for IPv6 Broadband
- Providing Protocol Support for Broadband Access Aggregation of PPP over ATM Sessions
- Providing Connectivity Using ATM Routed Bridge Encapsulation over PVCs
- PPPoE Circuit-Id Tag Processing
- Configuring PPP over Ethernet Session Limit Support
- PPPoE Session Limit Local Override
- PPPoE QinQ Support
- PPP-Max-Payload and IWF PPPoE Tag Support
- PPPoE Session Limiting on Inner QinQ VLAN
- PPPoE Agent Remote-ID and DSL Line Characteristics Enhancement
- Enabling PPPoE Relay Discovery and Service Selection Functionality
- Configuring Cisco Subscriber Service Switch Policies
- AAA Improvements for Broadband IPv6
- Per Session Queueing and Shaping for PPPoEoVLAN Using RADIUS
- 802.1P CoS Bit Set for PPP and PPPoE Control Frames
- PPP over Ethernet Client
- PPPoE Smart Server Selection
- Monitoring PPPoE Sessions with SNMP
- PPPoE on ATM
- PPPoE on Ethernet
- PPPoE over VLAN Enhancements Configuration Limit Removal and ATM Support
- ADSL Support in IPv6
- Broadband IPv6 Counter Support at LNS
- PPP IP Unique Address and Prefix Detection
- PPP IPv4 Address Conservation in Dual Stack Environments
- TR-069 Agent
- Broadband High Availability Stateful Switchover
- Broadband High Availability In-Service Software Upgrade
- Controlling Subscriber Bandwidth
- PPPoE Service Selection
- Disabling AC-name and AC-cookie Tags from PPPoE PADS
- Finding Feature Information
- Prerequisites for the PPPoE Circuit-Id Tag Processing Feature
- Information About the PPPoE Circuit-Id Tag Processing Feature
- How to Configure the PPPoE Circuit-Id Tag Processing Feature
- Configuration Examples for the PPPoE Circuit-Id Tag Processing Feature
- Additional References
- Feature Information for PPPoE Circuit-Id Tag Processing
PPPoE Circuit-Id Tag Processing
The PPPoE Circuit-Id Tag Processing feature provides a way to extract a Circuit-Id tag from the digital subscriber line (DSL) as an identifier for the authentication, authorization, and accounting (AAA) access request on a Fast Ethernet or Gigabit Ethernet interface, thereby simulating ATM-based Broadband access, but using cost-effective Fast Ethernet or Gigabit Ethernet instead. The tag is useful for troubleshooting the network, and is also used in RADIUS authentication and accounting processes.
- Finding Feature Information
- Prerequisites for the PPPoE Circuit-Id Tag Processing Feature
- Information About the PPPoE Circuit-Id Tag Processing Feature
- How to Configure the PPPoE Circuit-Id Tag Processing Feature
- Configuration Examples for the PPPoE Circuit-Id Tag Processing Feature
- Additional References
- Feature Information for PPPoE Circuit-Id Tag Processing
Finding Feature Information
Your software release may not support all the features documented in this module. For the latest caveats and feature information, see Bug Search Tool and the release notes for your platform and software release. To find information about the features documented in this module, and to see a list of the releases in which each feature is supported, see the feature information table.
Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to www.cisco.com/go/cfn. An account on Cisco.com is not required.
Prerequisites for the PPPoE Circuit-Id Tag Processing Feature
It is recommended that you be familiar with RFC 2516 before configuring this feature. See the Prerequisites for the PPPoE Circuit-Id Tag Processing Feature for a pointer to this standard.
Information About the PPPoE Circuit-Id Tag Processing Feature
- Differences Between ATM- and Fast or Gigabit Ethernet-Based Broadband Access Networks
- DSL Forum 2004-71 Solution
- Approach for a Circuit-Id Tag in Ethernet-Based Broadband Access Networks
- Benefits of the PPPoE Circuit-Id Tag Processing Feature
Differences Between ATM- and Fast or Gigabit Ethernet-Based Broadband Access Networks
Broadband digital subscriber line multiplexer (DSLAM) and Broadband Remote Access Server (BRAS) vendors see a need to provide Fast or Gigabit Ethernet-based networks as an alternative to an ATM access network, with a DSLAM bridging the ATM-DSL local loop to the Fast or Gigabit Ethernet-based access network and allowing Fast or Gigabit Ethernet-based connectivity to the BRAS. But in an Fast or Gigabit Ethernet access network, there is no unique mapping between the subscriber Line-Id and the interface, as is found in an ATM-based network. In an ATM-based network, the ATM VC is associated to a subscriber line.
During the authentication phase that initiates the PPP access and AAA accounting requests, the BRAS includes a NAS-Port-Id attribute in RADIUS authentication packets, if the feature "TAL based on the NAS-Port-Id" feature is configured. This attribute identifies the DSL line for the subscriber. See Configuring BRAS to Include a NAS-Port-Id Attribute Example for an example.
DSL Forum 2004-71 Solution
To apply the same subscriber mapping capability to Fast or Gigabit Ethernet interfaces that is possible on ATM interfaces, DSL Forum 2004-71 proposes a solution whereby the DSLAM sends the DSL Line-Id in the PPP over Ethernet (PPPoE) discovery phase. This method provides a way for a PPPoE server acting as a BRAS to extract the Line-Id tag and use the Circuit-Id field of that tag as a NAS-Port-Id attribute in AAA access and accounting requests. The PPPoE Circuit-Id Tag Processing feature makes use of the proposed DSL Forum 2004-71 method and allows the BRAS to detect the presence of the subscriber Circuit-Id tag inserted by the DSLAM during the PPPoE discovery phase. The BRAS will send this tag as a NAS-Port-Id attribute in PPP authentication and AAA accounting requests. The tag is useful in troubleshooting the Ethernet network, and it is also used in RADIUS authentication and accounting processes.
Approach for a Circuit-Id Tag in Ethernet-Based Broadband Access Networks
Traditional ATM-based DSL broadband access networks have the topology shown in the figure below.
In terms of logical connectivity, there is a one-to-one mapping of the DSL subscriber line to the end user and the ATM VC used to carry the PPP session through the DSLAM and to the BRAS, where this VC information is converted into a NAS-Port-Id for use in RADIUS packets.
The simple mapping available from an ATM-based network between the physical line in the DSL local loop to the end user and a VC (from DSLAM to BRAS) is not available for an Fast or Gigabit Ethernet-based network. To solve this problem, the PPPoE Circuit-Id Tag Processing feature uses a PPPoE intermediate agent function on the DSLAM to attach a tag to the PPPoE discovery packets. The BRAS then receives the tagged packet, decodes the tag, and inserts the line identifier into RADIUS packets destined for the RADIUS server.
DSLAM intercepts PPPoE discovery frames from the client and inserts a unique line identifier (circuit-id) using the PPPoE Vendor-Specific tag (0x0105) to PPPoE Active Discovery Initiation and Request (PADI and PADR) packets; see the figure below. The DSLAM forwards these packets to the BRAS after the insertion. The tag contains the circuit-id of the DSL line on which the PADI or PADR packet was received, in the access node where the intermediate agent resides.
When the vendor-tag circuit-id service command is configured in BBA (broadband access) group configuration mode, the BRAS processes the received PPPoE Vendor-Specific tag in the PADR packet and extracts the Circuit-Id field, which is sent to the remote AAA server as the NAS-Port-Id attribute (RADIUS attribute 87) in RADIUS access and accounting requests. When the radius-server attribute nas-port format d global configuration command is also configured on the BRAS, the Acct-Session-Id attribute will contain the information about the incoming access interface, where discovery frames are received, and about the session being established.
Outgoing PAD Offer and Session-confirmation (PADO and PADS) packets from the BRAS will have the DSLAM-inserted Circuit-Id tag. DSLAM should strip the tag out of PADO and PADS packets. If the DSLAM cannot strip off the tag, the BRAS should remove it before sending the packets out, and this is accomplished using the vendor-tag circuit-id strip BBA group configuration mode command.
Benefits of the PPPoE Circuit-Id Tag Processing Feature
The shift towards Fast or Gigabit Ethernet-based DSLAMs offers the following benefits:
Ability to use simpler and lower cost provisioning options for DSL subscribers over an Fast or Gigabit Ethernet-based backhaul network rather than on an ATM-based network.
Ability to use higher bandwidth connectivity options available from Fast or Gigabit Ethernet not possible on ATM.
Ability to upgrade to next-generation DSLAMs with quality of service (QoS), and support for higher bandwidth, asymmetric dual latency modems such as the ADSL2.
Ability to inject high-bandwidth content such as video in an Ethernet network.
How to Configure the PPPoE Circuit-Id Tag Processing Feature
- Configuring the PPPoE Circuit-Id Tag Processing Feature
- Removing the PPPoE Circuit-Id Tag
- Displaying the Session Activity Log
Configuring the PPPoE Circuit-Id Tag Processing Feature
This section describes how to configure an Fast or Gigabit Ethernet-based access network on a Cisco BRAS. The extracted Circuit-Id tag (see Information About the PPPoE Circuit-Id Tag Processing Feature) is sent in the following RADIUS syntax, as recommended by the DSL Forum:
"Access-Node-Identifier eth slot/port [:vlan-tag ]"
The Access-Node-Identifier is a unique subscriber identifier or telephone number text string entered without spaces. Per DSL-Forum 2004-71, the maximum length supported for the tag is 48 bytes. The BRAS copies the entire tag into the NAS-Port-Id and sends it to the AAA server.
1.
enable
2.
configure
terminal
3.
radius-server
attribute
nas-port
format
d
4.
bba-group
pppoe
group-name
5.
vendor-tag
circuit-id
service
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 |
enable
Example: Router> enable |
Enables privileged EXEC mode.
|
Step 2 |
configure
terminal
Example: Router# configure terminal |
Enters global configuration mode. |
Step 3 |
radius-server
attribute
nas-port
format
d
Example: Router(config)# radius-server attribute nas-port format d |
(Optional) Selects the PPPoE extended NAS-Port format used for RADIUS access and accounting.
|
Step 4 |
bba-group
pppoe
group-name
Example: Router(config-bba-group)# bba-group pppoe pppoe-group |
Defines a PPPoE profile. |
Step 5 |
vendor-tag
circuit-id
service
Example: Router(config-bba-group)# vendor-tag circuit-id service |
Enables processing of the received PPPoE Vendor-Specific tag in the PADR packet, which extracts the Circuit-Id part of the tag and sends it to the AAA server as the NAS-Port-Id attribute in RADIUS access and accounting requests. |
Removing the PPPoE Circuit-Id Tag
Outgoing PADO and PADS packets will have the DSLAM-inserted Vendor-Specific Line-Id tag, and DSLAM must strip the Circuit-Id tag from the packets. If the DSLAM cannot strip the tag, the BRAS must remove it before sending out the packets. This task is accomplished through configuration of the vendor-tag circuit-id strip command in BBA group configuration mode.
1.
enable
2.
configure
terminal
3.
bba-group
pppoe
group-name
4.
vendor-tag
strip
DETAILED STEPS
Displaying the Session Activity Log
When the radius-server attribute nas-port format d global configuration command is added to the PPPoE Circuit-Id Tag Processing feature configuration on the BRAS (see the Configuring PPPoE Circuit-Id Tag Processing Example for an example), the report from the debug radius privileged EXEC command will include information about the incoming access interface, where discovery frames are received, and about the session being established in PPPoE extended NAS-Port format (format d).
Enable the debug radius command to display a report of session activity. In the example shown in this section:
The acct_session_id is 79 or 4F in hexadecimal format.
In the message "Acct-session-id pre-pended with Nas Port = 0/0/0/200," the interface on which the PPPoE discovery frames arrived is FastEthernet0/0.200. The 0/0/0 is Cisco format for slot/subslot/port.
The Acct-Session-Id vendor-specific attribute 44 contains the string "0/0/0/200_0000004F," which is a combination of the ingress interface and the session identifier.
Note | Strings of interest in the debug radius output log are presented in bold text for example purposes only. |
Router# debug radius 02:10:49: RADIUS(0000003F): Config NAS IP: 0.0.0.0 02:10:49: RADIUS/ENCODE(0000003F): acct_session_id: 79 02:10:49: RADIUS(0000003F): sending 02:10:49: RADIUS/ENCODE: Best Local IP-Address 10.0.58.141 for Radius-Server 172.20.164.143 02:10:49: RADIUS(0000003F): Send Access-Request to 172.20.164.143:1645 id 1645/65, len 98 02:10:49: RADIUS: authenticator 1C 9E B0 A2 82 51 C1 79 - FE 24 F4 D1 2F 84 F5 79 02:10:49: RADIUS: Framed-Protocol [7] 6 PPP [1] 02:10:49: RADIUS: User-Name [1] 7 "peer1" 02:10:49: RADIUS: CHAP-Password [3] 19 * 02:10:49: RADIUS: NAS-Port-Type [61] 6 Ethernet [15] 02:10:49: RADIUS: NAS-Port [5] 6 200 02:10:49: RADIUS: NAS-Port-Id [87] 22 "FastEthernet6/0.200:" 02:10:49: RADIUS: Service-Type [6] 6 Framed [2] 02:10:49: RADIUS: NAS-IP-Address [4] 6 10.0.58.141 02:10:49: RADIUS: Received from id 1645/65 172.20.164.143:1645, Access-Accept, len 32 02:10:49: RADIUS: authenticator 06 45 84 1B 27 1F A5 C3 - C3 C9 69 6E B9 C0 6F 94 02:10:49: RADIUS: Service-Type [6] 6 Framed [2] 02:10:49: RADIUS: Framed-Protocol [7] 6 PPP [1] 02:10:49: RADIUS(0000003F): Received from id 1645/65 02:10:49: [62]PPPoE 65: State LCP_NEGOTIATION Event PPP_LOCAL 02:10:49: PPPoE 65/SB: Sent vtemplate request on base Vi2 02:10:49: [62]PPPoE 65: State VACCESS_REQUESTED Event VA_RESP 02:10:49: [62]PPPoE 65: Vi2.1 interface obtained 02:10:49: [62]PPPoE 65: State PTA_BINDING Event STAT_BIND 02:10:49: [62]PPPoE 65: data path set to Virtual Acess 02:10:49: [62]PPPoE 65: Connected PTA 02:10:49: [62]PPPoE 65: AAA get dynamic attrs 02:10:49: [62]PPPoE 65: AAA get dynamic attrs 02:10:49: RADIUS/ENCODE(0000003F):Orig. component type = PPoE 02:10:49: RADIUS/ENCODE(0000003F): Acct-session-id pre-pended with Nas Port = 0/0/0/200 02:10:49: RADIUS(0000003F): Config NAS IP: 0.0.0.0 02:10:49: RADIUS(0000003F): sending 02:10:49: RADIUS/ENCODE: Best Local IP-Address 10.0.58.141 for Radius-Server 172.20.164.143 02:10:49: RADIUS(0000003F): Send Accounting-Request to 172.20.164.143:1646 id 1 646/42, len 117 02:10:49: RADIUS: authenticator 57 24 38 1A A3 09 62 42 - 55 2F 41 71 38 E1 CC 24 02:10:49: RADIUS: Acct-Session-Id [44] 20 "0/0/0/200_0000004F" 02:10:49: RADIUS: Framed-Protocol [7] 6 PPP [1] 02:10:49: RADIUS: User-Name [1] 7 "peer1" 02:10:49: RADIUS: Acct-Authentic [45] 6 RADIUS [1] 02:10:49: RADIUS: Acct-Status-Type [40] 6 Start [1] 02:10:49: RADIUS: NAS-Port-Type [61] 6 Ethernet [15] 02:10:49: RADIUS: NAS-Port [5] 6 200 02:10:49: RADIUS: NAS-Port-Id [87] 22 "FastEthernet6/0.200:" 02:10:49: RADIUS: Service-Type [6] 6 Framed [2] 02:10:49: RADIUS: NAS-IP-Address [4] 6 10.0.58.141 02:10:49: RADIUS: Acct-Delay-Time [41] 6 0 02:10:49: RADIUS: Received from id 1646/42 172.20.164.143:1646, Accounting-resp onse, len 20 02:10:49: RADIUS: authenticator 34 84 7E B2 F4 40 B2 7C - C5 B2 4E 98 78 03 8B C0
Configuration Examples for the PPPoE Circuit-Id Tag Processing Feature
- Configuring PPPoE Circuit-Id Tag Processing Example
- Configuring BRAS to Include a NAS-Port-Id Attribute Example
- Removing the PPPoE Circuit-Id Tag Example
Configuring PPPoE Circuit-Id Tag Processing Example
In the following example, outgoing PADO and PADS packets will retain the incoming Vendor-Specific Circuit-Id tag:
radius-server attribute nas-port format d ! bba-group pppoe pppoe-group sessions per-mac limit 50 vendor-tag circuit-id service ! interface FastEthernet0/0.1 encapsulation dot1Q 120 pppoe enable group pppoe-group
Configuring BRAS to Include a NAS-Port-Id Attribute Example
In the following example, the feature TAL based on the NAS-Port-Id is configured. This configuration ensures that a NAS-Port-Id attribute is included in RADIUS authentication packets during the authentication phase to initiate PPP access and AAA accounting requests.
radius-server attribute nas-port policy-map type control test class type control always event session-start 1 authorize identifier nas-port
Removing the PPPoE Circuit-Id Tag Example
In the following example, the BRAS will strip off incoming Vendor-Specific Circuit-Id tags from outgoing PADO and PADS packets:
bba-group pppoe pppoe-rm-tag sessions per-mac limit 50 vendor-tag circuit-id service vendor-tag strip interface FastEthernet0/0.1 encapsulation dot1Q 120 pppoe enable group pppoe-group
Additional References
The following sections provide references related to the PPPoE Circuit-Id Tag Processing feature.
Related Documents
Related Topic |
Document Title |
---|---|
Configuring Broadband and DSL |
Cisco IOS XE Broadband Access Aggregation and DSL Configuration Guide |
RADIUS attributes |
Cisco IOS XE Security Configuration Guide |
DSL Forum Line-Id tag solution |
Standards
Standard |
Title |
---|---|
None |
-- |
MIBs
MIB |
MIBs Link |
---|---|
None |
To locate and download MIBs for selected platforms, Cisco IOS XE software releases, and feature sets, use Cisco MIB Locator found at the following URL: |
RFCs
RFC |
Title |
---|---|
RFC 2516 |
Technical Assistance
Description |
Link |
---|---|
The Cisco Support website provides extensive online resources, including documentation and tools for troubleshooting and resolving technical issues with Cisco products and technologies. To receive security and technical information about your products, you can subscribe to various services, such as the Product Alert Tool (accessed from Field Notices), the Cisco Technical Services Newsletter, and Really Simple Syndication (RSS) Feeds. Access to most tools on the Cisco Support website requires a Cisco.com user ID and password. |
http://www.cisco.com/techsupport |
Feature Information for PPPoE Circuit-Id Tag Processing
The following table provides release information about the feature or features described in this module. This table lists only the software release that introduced support for a given feature in a given software release train. Unless noted otherwise, subsequent releases of that software release train also support that feature.
Use Cisco Feature Navigator to find information about platform support and Cisco software image support. To access Cisco Feature Navigator, go to www.cisco.com/go/cfn. An account on Cisco.com is not required.
Feature Name |
Releases |
Feature Information |
---|---|---|
PPPoE Circuit-Id Tag Processing |
Cisco IOS XE Release 2.1. |
The PPPoE Circuit-Id Tag Processing feature provides a way to extract a Circuit-Id tag from the DSL as an identifier for the AAA access request on an Ethernet interface, thereby simulating ATM-based broadband access, but using cost-effective Ethernet instead. The tag is useful for troubleshooting the network, and is also used in RADIUS authentication and accounting processes. This feature was introduced on Cisco ASR 1000 Series Aggregation Services Routers. This feature was integrated into Cisco IOS XE Release 2.3.1. The following commands were introduced or modified: vendor-tag circuit-id service, vendor-tag strip. |