show upstream oob configuration
To display the upstream oob configuration, use the show upstream oob configuration command in privileged EXEC mode.
show upstream oob configuration { 55d1 | 55d2} { uepi 55d1 | uepi 55d2} { ndr}
Command Default
None.
Command Modes
Privileged EXEC (#) (FCC, Line Card, and Non-Primary eRPD)
Command History
Release |
Modification |
---|---|
Cisco Remote PHY Shelf 7200 Software 1.1 |
This command was introduced on the Cisco Remote PHY Shelf 7200. |
Examples
The following is a sample output of the show upstream oob configuration ndr command. The command displays the NDR in OOB channel configuration:
R-PHY#show upstream oob configuration ndr
USOOB NDR bcm configuration:
Port Chan IntChan State Enabled Frequency Mode Sessionid QOS MTU PowerAdjust CalcuFreq RegFreq VGA Gain SetPoint
0 1 1 UP 1 5000000 1.28 MHz 0xf0001111 0 1500 0 3f9c0000 3f9c0000 11 14 0.000000
NDR Server information
gch ipv6 dip dipv6 dmac mtu qos
1 1 0.0.0.0 2001:30:84:0:1:0:36:e523 c4:14:3c:16:d4:07 1500 0