Operating Temperature Specifications
![]() Note |
The safety certifications apply only to ambient temperatures under 140°F (60°C). However, the Cisco IE3500 Heavy Duty Series Switches can function in substation and traffic signal installations under the environmental conditions described in the table. |
The table lists the operating temperatures for the Cisco IE3500 Heavy Duty Series Switches in three different environments.
|
Industrial Automation and Other Locations Requiring Enclosures |
Substation |
Traffic Signal |
|||
|---|---|---|---|---|---|
|
Enclosure types |
Sealed enclosures For example: NEMA 4, NEMA 4X, NEMA 12, NEMA 13, IP54, and IP66 -40 °C to +60 °C (-40 °F to +140 °F) |
Vented enclosures For example: NEMA 1, IP66, and IP67 -40 °C to +70 °C (-40 °F to +158 °F) |
Fan or blower-equipped enclosures For example: NEMA TS-2. -34 °C to +75 °C (-29.2 °F to +167 °F)
|