The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This document is for individuals who are new to Cisco Intersight® and are looking for a summary and definitions of the domain, chassis, and server policies available in Intersight. Information is broken down by policies for servers using Intersight Managed Mode (IMM) and those using Intersight Standalone Mode (ISM). It includes a list of the minimum recommended policies to deploy a server. Detailed instructions on how to use policies are available in the Additional Resources section.
This document is a complementary piece to “Stateless Computing with Cisco UCS® and Cisco Intersight,” which describes the core concepts of stateless computing and how policies, profiles, and templates form the foundation of efficient and secure server management.
Cisco Intersight policies are configurations that define specific settings and behaviors for various components within IT infrastructure. Policies help enforce secure deployments and ensure consistency across server configurations. Along with fabric interconnects, profiles, and templates, they are a foundational element of stateless computing and enable flexible and dynamic server management.
In Cisco Intersight, a domain policy allows you to configure various parameters for Cisco Unified Computing System™ (Cisco UCS) fabric interconnects, including port configuration, network control settings, and VLAN and VSAN settings. A domain policy can be assigned to any number of domain profiles to provide a configuration baseline.
● Certificate Management Policy
Allows you to specify the certificate details for an external certificate and attach the policy to server profile or to domain profile. Intersight currently supports Root CA and IMC certificates.
● Ethernet Network Control Policy
Configures the network control settings for a UCS domain; applicable only for the appliance ports defined in a port policy.
● Ethernet Network Group Policy
Configures the allowed VLANs and native VLAN for Ethernet uplink ports, Ethernet uplink port channels, appliance ports, or appliance port channels. This policy is only attached to the domain profile if using a disjoint Layer-2 (DJL2) use case or an appliance-port use case. If not using an appliance-port use case (and if uplinking Ethernet to a single Layer-2 broadcast domain), then this policy will not be applied to a domain profile. It is most used for disjoint Layer-2 use cases.
● Flow Control Policy
Configures the priority flow control for ports and port channels to enable the no-drop behavior for the CoS defined by the System QoS Policy and an Ethernet QoS policy.
● Link Aggregation Policy
Used to configure link-aggregation properties. Combines multiple network connections in parallel to increase throughput and provide redundancy. Link aggregation is achieved using port channels; a port channel is an aggregation of multiple physical interfaces into a logical interface.
● Link Control Policy
Enables configuration of link control administrative state and configuration (normal or aggressive) mode for ports.
● Multicast Policy
Configures Internet Group Management Protocol (IGMP) snooping and IGMP querier. Each VLAN added in the VLAN policy must have a Multicast policy configured for it in Intersight.
● Network Connectivity Domain (DNS) Policy
Specifies the DNS server settings for IPv4 and IPv6 for the fabric interconnects.
● NTP (Network Time Protocol) Policy
Enables the NTP service to configure a Cisco UCS system that is managed by Cisco Intersight to synchronize the time with an NTP server. You must enable and configure the NTP service by specifying the IP/DNS address of at least one server or a maximum of four servers that function as NTP servers. When you enable the NTP service, Cisco Intersight configures the NTP details on the endpoint.
● Port Policy
Used for configuring the port parameters such as unified ports that carry Ethernet or Fibre Channel traffic, port roles and speed.
● SNMP (Simple Network Management Protocol) Policy
Configures the SNMP settings for sending fault and alert information by SNMP traps from the managed devices. This policy supports SNMP versions such as SNMPv1, SNMPv2 (includes v2c), and SNMPv3. Any existing SNMP users or SNMP traps configured previously on the managed devices are removed and replaced with users or traps that you configure in this policy.
● Switch Control Policy
Supports VLAN port count optimization, configuring MAC address aging time, and configuring link-control global settings.
● Syslog Policy
Defines the minimum severity as the logging level from an endpoint. The policy also defines the target destination to store syslog messages, and the hostname or IP address, the port information, and the communication protocol for the remote logging servers.
● System QoS Policy
Assigns a system class to the outgoing traffic; determines the quality of service for the outgoing traffic. All domain profiles must include this policy for successful deployment; may be default settings.
● VLAN Policy
Must include all the VLANs communicating between the UCS domain fabric and upstream switching. Cannot add a server policy (Ethernet Network Group) unless the VLAN is already deployed in the VLAN Policy and domain profile.
● VSAN Policy
Partitions the Fibre Channel fabric into one or more zones. Each zone defines the set of Fibre Channel initiators and Fibre Channel targets that can communicate with each other in a VSAN.
Server policies are used to define and manage configurations for Cisco UCS servers. These policies can include settings for server BIOS, local disk configurations, boot security, and maintenance windows, among others. Server policies enhance security by enforcing predefined settings and help ensure consistency, efficiency, and flexibility in server management by allowing administrators to apply the same configuration settings across multiple servers. Server configurations only change if the Intersight administrator updates or changes policies.
Policies are available for the two management modes in Intersight: Intersight Managed Mode (IMM) and Intersight Standalone Mode (ISM). IMM is used for Cisco UCS fabric interconnected systems, and ISM is used for servers not connected to UCS fabric interconnects. Note that Cisco C-Series rack mount servers can be configured as either IMM or ISM. Some of the sever policies are specific to IMM, and others are specific to ISM exclusively. The following summary aids in identifying them so you can ensure you are working with the correct policies.
Server policies for Intersight Managed Mode (IMM)
Minimum policies to deploy a server
● BIOS Policy
Automates the configuration of BIOS settings on servers. You can create one or more BIOS policies that contain a specific grouping of BIOS settings, matching the needs of a server or a set of servers. If you do not specify a BIOS policy for a server, the BIOS settings will default to a set of values for a brand-new bare metal server or to a set of values previously configured using Cisco IMC. If a BIOS policy is specified, its values replace any previously configured values on the server.
● Boot Order Policy
Configures the linear ordering of devices and enables you to change the boot order and boot mode. You can also add multiple devices under various device types, rearrange the boot order, and set parameters for each boot device type.
● Ethernet Adapter Policy
Governs the host-side behavior of the adapter, including how the adapter handles traffic. For each VIC virtual Ethernet interface, you can configure various features, such as Virtual Extensible LAN (VXLAN), Network Virtualization using Generic Routing Encapsulation (NVGRE), Accelerated Receive Flow Steering (ARFS), interrupt settings, and TCP offload settings.
● Ethernet Network Control Policy
This policy can be configured on each vNIC of the LAN Connectivity policy and configures how each vNIC is discoverable on the network using Cisco Discovery Protocol (CDP) and/or Link Level Discovery Protocol (LLDP). Additional settings include MAC registration mode, MAC security, and actions taken on uplink fail behavior.
● Ethernet Network Group Policy
Enables you to manage settings for VLANs on each vNIC on a UCS server. These settings include defining which VLANs are allowed, designating a native VLAN, and specifying an optional QinQ VLAN.
● IMC Access Policy
Allows you to configure your network and associate an IP address from an IP pool with a server. In-band IP address, out-of-band IP address, or both in-band and out-of-band IP addresses can be configured using an IMC Access policy and are supported on drive security, SNMP, syslog, and vMedia policies.
● LAN Connectivity Policy
Determines the connections and the network communication resources between the server and the LAN on the network. You can specify MAC address pools, or static MAC addresses, to assign MAC addresses to servers and to identify the vNICs that the servers use to communicate with the network.
● Local User Policy
Defines local user access to the server. You can create one or more local user policies which contain a list of local users that need to be configured.
● Storage Policy
Allows you to create drive groups and virtual drives, and configure both the storage capacity of a virtual drive and the M.2 RAID controllers.
● Virtual KVM Policy
The KVM console is an interface that emulates a direct keyboard, video, and mouse (KVM) connection to the server. It allows you to control the server from a remote location and to map physical locations to virtual drives that can be accessed by the server during this KVM session. Enables specific groupings of virtual KVM properties; lets you specify the number of allowed concurrent KVM sessions, port information, and video encryption options.
● Virtual Media (vMedia) Policy
Enables you to install an operating system on the server using the KVM console and virtual media, mount files to the host from a remote file share, and enable virtual media encryption. You can create one or more virtual media policies, which can contain virtual media mappings for different OS images, and configure up to two virtual media mappings, one for ISO files through CDD and the other for IMG files through HDD.
Optional server policies based on use case
● Certificate Management Policy
Allows you to specify the certificate details for an external certificate and attach the policy to a server profile or to a domain profile. Intersight currently supports Root CA and IMC certificates.
● Drive Security Policy
Enables you to configure security keys either locally or remotely using a KMIP server.
● Ethernet QoS Policy
Assigns a system class to the outgoing traffic for a vNIC. This system class determines the quality of service for the outgoing traffic. For certain adapters, you can also specify additional controls such as burst and rate on the outgoing traffic.
● FC Zone Policy
Allows you to set up access control between hosts and storage devices. This policy is only used for direct attached storage use cases with the fabric interconnect setup in FC-switching mode.
● Fibre Channel Adapter Policy
Governs the host-side behavior of the adapter, including how the adapter handles traffic. You can enable FCP error recovery, change the default settings of queues, and interrupt handling for performance enhancement.
● Fibre Channel Network Policy
Governs the Virtual Storage Area Network (VSAN) configuration for the virtual host-bus adapter (vHBA) interfaces in the SAN Connectivity Policy.
● Fibre Channel QoS Policy
Assigns a system class to the outgoing traffic for a vHBA and determines the quality of service for the outgoing traffic. For certain adapters, you can also specify additional controls such as burst and rate on the outgoing traffic.
● Firmware Policies
Allows the designation of a server firmware bundle version to be attached to the server profile and deployed to the server endpoint. When you deploy the server profile, the server firmware is upgraded.
● IPMI Over LAN Policy
Defines the protocols for remote interfacing with a service processor that is embedded in a server platform. The Intelligent Platform Management Interface (IPMI) enables an operating system to obtain information about the system-health and control-system hardware and directs the Cisco IMC to perform the required actions. You can create an IPMI over LAN policy to manage the IPMI messages through Cisco Intersight.
● iSCSI Adapter Policy
Allows you to configure values for TCP connection timeout, DHCP timeout, and the retry count if the specified LUN ID is busy. This policy is used on iSCSI configured vNICs.
● iSCSI Boot Policy
Allows you to initialize the operating system on FI-attached blade and rack servers from a remote disk across a storage area network (SAN). The remote disk, known as the target, is accessed using TCP/IP and iSCSI boot firmware.
● iSCSI Static Target Policy
Allows you to specify the name, IP address, port, and logical unit number of the primary target for iSCSI boot. You can optionally specify these details for a secondary target as well.
● LDAP Policy
Lightweight Directory Access Protocol (LDAP) stores and maintains directory information in a network. When LDAP is enabled, user authentication and role authorization is performed by the LDAP server for user accounts not found in the local user database. You can enable and configure LDAP servers and LDAP groups.
● Network Connectivity Policy
Enables you to configure and assign IPv4 and IPv6 addresses.
● NTP Policy
Enables the NTP service to configure a Cisco UCS system that is managed by Cisco Intersight to synchronize the time with an NTP server. You must enable and configure the NTP service by specifying the IP/DNS address of at least one server or a maximum of four servers that function as NTP servers. When you enable the NTP service, Cisco Intersight configures the NTP details on the endpoint.
● Memory Policy
Allows you to enable or disable the blocklisting of dual in-line memory modules (DIMMs).
● Power Policy
Enables the configuration of power redundancy, power profiling, and power restoration for servers. The power profiling setting is only applicable to Cisco UCS X-Series servers.
● SAN Connectivity Policy
A storage area network (SAN) connectivity policy determines the network storage resources and the connections between the server and the storage device on the network. This policy enables you to specify WWPN address pools, or a static WWPN address to add a vHBA. Similarly, you can specify a WWNN pool, or a static WWNN address to configure vHBAs that the servers use to communicate with the SAN.
● Scrub Policy
Allows for the BIOS and/or disk to be scrubbed on the server. Occurs when configured and attached to a server profile, and when the server profile is detached from the server.
● SD Card Policy
Configures the Cisco FlexFlash and FlexUtil secure digital (SD) cards for the Cisco UCS C-Series Standalone M4 and M5 servers, and Cisco UCS C-Series M5 servers in a Cisco Intersight-managed fabric interconnect domain. This policy specifies details of virtual drives on the SD cards. You can configure the SD cards in operating system only, utility only, or operating system + utility modes.
● Serial Over LAN Policy
Enables the input and output of the serial port of a managed system to be redirected over IP. You can create one or more serial over LAN policies which contain a specific grouping of serial over LAN attributes that match the needs of a server or a set of servers.
● Server Pool Qualification Policy
Supports setting domain, server, tag, and hardware qualifiers to logically auto-populate the servers into a server resource pool that can be assigned to the server profile and/or server profile template.
● SNMP Policy
Configures the SNMP settings for sending fault and alert information by SNMP traps from the managed devices. This policy supports SNMP versions such as SNMPv1, SNMPv2 (includes v2c), and SNMPv3. Any existing SNMP users or SNMP traps configured previously on the managed devices are removed and replaced with users or traps that you configure in this policy. If you have not added any users or traps in the policy, the existing users or traps on the server are removed.
● Syslog Policy
Defines the logging level (minimum severity) to report for a log file collected from an endpoint, the target destination to store the syslog messages, and the hostname/IP address, port information, and communication protocol for the remote logging server(s).
● Thermal Policy
Sets the fan-speed modes on Cisco UCS X-Series servers.
Server policies for Intersight Standalone Mode (ISM)
Cisco® rack mount servers operating in Intersight Standalone Mode—connected directly to Intersight without fabric interconnects—use the following policies:
BIOS |
Fibre Channel QoS |
SD Card |
Boot Order |
Firmware |
Serial Over LAN |
Certificate Management |
IPMI Over LAN |
SNMP |
Drive Security |
LAN Connectivity |
Storage |
Ethernet Adapter |
Local User |
Syslog |
Ethernet QoS |
Memory |
Thermal |
Fibre Channel Adapter |
Power |
Virtual KVM |
Fibre Channel Network |
SAN Connectivity |
Virtual Media |
In addition, the following server policies are applicable only to ISM-managed servers:
● Adapter Configuration
Configures the Ethernet and Fibre-Channel settings for the Virtual Interface Card (VIC) adapter.
● Device Connector Policy
Lets you choose the configuration from Intersight only option to control configuration changes allowed in Cisco IMC. The configuration from Intersight only option is enabled by default.
● Ethernet Network Policy
Enables the configuration of VLAN mode (access or trunk), the QinQ tagging option, and the default native VLAN.
● LDAP (standalone and domain)
Lightweight Directory Access Protocol (LDAP) stores and maintains directory information in a network. When LDAP is enabled, user authentication and role authorization are performed by the LDAP server for user accounts not found in the local user database. You can enable and configure LDAP servers and LDAP groups.
● Network Connectivity (standalone and domain)
Enables dynamic DNS or lets you manually designate IPv4 and IPv6 DNS addresses.
● NTP (standalone and domain)
Enables the NTP service to configure a UCS system that is managed by Cisco Intersight to synchronize the time with an NTP server. You must enable and configure the NTP service by specifying the IP/DNS address of at least one server or a maximum of four servers that function as NTP servers. When you enable the NTP service, Cisco Intersight configures the NTP details on the endpoint.
● Persistent Memory
Only applicable to Cisco UCS C-Series – special memory (PMem modules) that provide low latency and persistent storage.
● SMTP
Simple Mail Transfer Protocol (SMTP) sends server faults as email alerts to the configured SMTP server.
● SSH
Enables an SSH client to make a secure, encrypted connection. You can create one or more SSH policies that contain a specific grouping of SSH properties for a server or a set of servers.
Chassis policies for Intersight Management Mode
● IMC Access
Allows you to configure your network and associate an IP address from an IP pool with a server. In-band IP address, out-of-band IP address, or both in-band and out-of-band IP addresses can be configured using IMC Access policy and is supported on drive security, SNMP, syslog, and vMedia policies.
● Power
Enables configuration of power redundancy and power allocation for the chassis.
● SNMP
Configures the SNMP settings for sending fault and alert information by SNMP traps from the managed devices. This policy supports SNMP versions such as SNMPv1, SNMPv2 (includes v2c), and SNMPv3. Any existing SNMP users or SNMP traps configured previously on the managed devices are removed and replaced with users or traps that you configure in this policy. If you have not added any users or traps in the policy, the existing users or traps on the input/output module (IOM) are removed.
● Thermal
Used to set configuration parameters for chassis fans.
Creating and managing policies
Multiple instructional materials are available to help you get started with Cisco Intersight. The Cisco Intersight Managed Mode Configuration Guide provides step-by-step instructions and tutorials on creating and assigning policies and profiles in Intersight, including:
Profile configuration
● Configuring UCS Domain Profiles
● Configuring UCS Chassis Profiles
Policy configuration
● Configuring UCS Domain Policies
● Configuring UCS Chassis Policies
The Intersight SaaS Help Center provides detailed information on getting started with profiles, policies, and templates. And the Intersight IMM Expert Series on the Cisco Compute YouTube channel provides instructor-led examples on creating individual policies and profiles.
Subscribe to these IMM Expert Series playlists on the Cisco Compute YouTube channel:
● Domain Policies and Domain Profiles
● Server Policies and Server Profiles
● ID Pools
Become part of the Cisco Intersight Community to ask questions, share best practices, and learn from other Intersight users. The community is open to everyone. Join the community and explore other Cisco Communities here.
Once you have joined the Intersight Community, get access to the Intersight product and technical teams along with special programs and events by becoming an Intersight Insider. After becoming a community member, ask to become a member on the Intersight Insider Group Hub page.
Appendix: Cisco Intersight Policies At-a-Glance
Policy |
Chassis |
Domain |
IMM |
ISM |
SNMP |
X |
X |
X |
X |
Power |
X |
X |
X |
|
*IMC Access |
X |
X |
||
Thermal |
X |
X |
||
Certificate Management |
X |
X |
X |
|
Ethernet Network Control Policy |
X |
X |
X |
|
Ethernet Network Group |
X |
X |
X |
|
Syslog |
X |
X |
X |
|
Network Connectivity |
X |
X |
||
NTP |
X |
X |
||
LDAP (standalone and domain) |
X |
ISM only |
||
Network Connectivity (standalone and domain) |
X |
ISM only |
||
NTP (standalone and domain) |
X |
ISM only |
||
Flow Control |
X |
|||
Link Aggregation |
X |
|||
Link Control |
X |
|||
Multicast |
X |
|||
Port |
X |
|||
Switch Control |
X |
|||
System QoS |
X |
|||
VLAN |
X |
|||
VSAN |
X |
|||
*BIOS |
X |
X |
||
*Boot Order |
X |
X |
||
*LAN Connectivity |
X |
X |
||
*Local User |
X |
X |
||
*Storage |
X |
X |
||
*Virtual KVM |
X |
X |
||
*Virtual Media |
X |
X |
||
Drive Security |
X |
X |
||
Ethernet Adapter Policy |
X |
X |
||
Ethernet QoS |
X |
X |
||
Fibre Channel Adapter |
X |
X |
||
Fibre Channel Network |
X |
X |
||
Fibre Channel QoS |
X |
X |
||
Firmware |
X |
X |
||
IPMI Over LAN |
X |
X |
||
Memory |
X |
X |
||
SAN Connectivity |
X |
X |
||
SD Card |
X |
X |
||
Serial Over LAN |
X |
X |
||
FC Zone |
X |
|||
iSCSI Adapter |
X |
|||
ISCSI Boot |
X |
|||
iSCSI Static Target |
X |
|||
LDAP |
X |
|||
Scrub |
X |
|||
Adapter Configuration |
ISM only |
|||
Device Connector |
ISM only |
|||
Ethernet Network |
ISM only |
|||
Persistent Memory |
ISM only |
|||
SMTP |
ISM only |
|||
SSH |
ISM only |