Cisco ONS 15454 SDH TL1 Command Guide, Release 6.0
Chapter 21, RTRV Commands

Table Of Contents

RTRV Commands

21.1  RTRV-<MOD1FCPAYLOAD>

21.2  RTRV-<MOD1FICONPAYLOAD>

21.3  RTRV-<MOD2DWDMPAYLOAD>

21.4  RTRV-<MOD_RING>

21.5  RTRV-<PATH>

21.6  RTRV-<STM_TYPE>

21.7  RTRV-10GIGE

21.8  RTRV-ALM-<MOD2ALM>

21.9  RTRV-ALM-ALL

21.10  RTRV-ALM-BITS

21.11  RTRV-ALM-ENV

21.12  RTRV-ALM-EQPT

21.13  RTRV-ALM-SYNCN

21.14  RTRV-ALMTH-<MOD2>

21.15  RTRV-ALMTH-EQPT

21.16  RTRV-ALS

21.17  RTRV-APC

21.18  RTRV-ATTR-CONT

21.19  RTRV-ATTR-ENV

21.20  RTRV-AUDIT-LOG

21.21  RTRV-BITS

21.22  RTRV-BULKROLL<STM_TYPE>

21.23  RTRV-CMD-SECU

21.24  RTRV-COND-<MOD2ALM>

21.25  RTRV-COND-ALL

21.26  RTRV-COND-BITS

21.27  RTRV-COND-ENV

21.28  RTRV-COND-EQPT

21.29  RTRV-COND-SYNCN

21.30  RTRV-CONSOLE-PORT

21.31  RTRV-CRS

21.32  RTRV-CRS-<PATH>

21.33  RTRV-DFLT-SECU

21.34  RTRV-DS3I

21.35  RTRV-E1

21.36  RTRV-E3

21.37  RTRV-E4

21.38  RTRV-EQPT

21.39  RTRV-ESCON

21.40  RTRV-EXT-CONT

21.41  RTRV-FAC

21.42  RTRV-FFP

21.43  RTRV-FFP-<MOD2DWDMPAYLOAD>

21.44  RTRV-FFP-<STM_TYPE>

21.45  RTRV-FFP-OCH

21.46  RTRV-FSTE

21.47  RTRV-G1000

21.48  RTRV-GFP

21.49  RTRV-GIGE

21.50  RTRV-HDR

21.51  RTRV-INV

21.52  RTRV-LNK

21.53  RTRV-LNK-<MOD2O>

21.54  RTRV-LNKTERM

21.55  RTRV-LOG

21.56  RTRV-MAP-NETWORK

21.57  RTRV-NE-APC

21.58  RTRV-NE-GEN

21.59  RTRV-NE-IPMAP

21.60  RTRV-NE-PATH

21.61  RTRV-NE-SYNCN

21.62  RTRV-NE-WDMANS

21.63  RTRV-NETYPE

21.64  RTRV-OCH

21.65  RTRV-OMS

21.66  RTRV-OPM

21.67  RTRV-OSC

21.68  RTRV-OTS

21.69  RTRV-PM-<MOD2>

21.70  RTRV-PMMODE-<VC_PATH>

21.71  RTRV-PMSCHED-<MOD2>

21.72  RTRV-PMSCHED-ALL

21.73  RTRV-POS

21.74  RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

21.75  RTRV-PROTNSW-<STM_TYPE>

21.76  RTRV-PROTNSW-<PATH>

21.77  RTRV-PROTNSW-OCH

21.78  RTRV-PROTOCOL

21.79  RTRV-PTHTRC-<PATH>

21.80  RTRV-RMONTH-<MOD2_RMON>

21.81  RTRV-ROLL-<MOD_PATH>

21.82  RTRV-ROUTE

21.83  RTRV-ROUTE-GRE

21.84  RTRV-SLV-WDMANS

21.85  RTRV-STM1E

21.86  RTRV-SYNCN

21.87  RTRV-TACC

21.88  RTRV-TADRMAP

21.89  RTRV-TH-<MOD2>

21.90  RTRV-TH-ALL

21.91  RTRV-TOD

21.92  RTRV-TRAPTABLE

21.93  RTRV-TRC-<STM_MSSPR>

21.94  RTRV-TRC-OCH

21.95  RTRV-TUNNEL-FIREWALL

21.96  RTRV-TUNNEL-PROXY

21.97  RTRV-USER-SECU

21.98  RTRV-VCG

21.99  RTRV-WDMANS

21.100  RTRV-WLEN


RTRV Commands


This chapter provides RTRV (retrieve) commands for the Cisco ONS 15454 SDH.

21.1  RTRV-<MOD1FCPAYLOAD>

Retrieve (1GFC, 2GFC)

Usage Guidelines

This command retrieves the attributes related with the Fibre Channel port.

See Table 27-1 on page 27-1 for supported modifiers by platform.

Category

Ports

Security

Retrieve

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<STM_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<STM_TYPE>

ED-ALS

ED-DS3I

ED-E1/ED-E3/ED-E4

ED-FAC

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<STM_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-STM1E

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<STM_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<STM_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<STM_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<STM_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS3I

RTRV-E1/RTRV-E3/RTRV-E4

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<STM_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<STM_TYPE>

RTRV-STM1E

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

RTRV-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];

Input Example

RTRV-1GFC:CISCO:FAC-6-1:888;

Input Parameters

Table 21-1 RTRV-<MOD1FCPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16. Must not be null


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>:,,[<ROLE>],[<STATUS>]:LINKRATE=<LINKRATE>,LINKSTATE=<LINKSTATE>,
[LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTEXTN>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[ENCAP=<ENCAP>],[NAME=<NAME>],
[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:
<PST_PSTQ>,[<SST>]"
;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-1-1:,,WORK,ACT:LINKRATE=1GFC,LINKSTATE=UP,LINKRCVRY=Y,
DISTEXTN=NONE,LINKCREDITS=0,MFS=2148,ENCAP=GFP-T,
NAME=\"FC PORT\",SOAK=32,SOAKLEFT=\"12-25\",FREQ=1550,
LOSSB=LR-1:LOCKED-ENABLED,MAINTENANCE"
;

Output Parameters

Table 21-2 RTRV-<MOD1FCPAYLOAD> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16

ROLE

The port role in a Y-cable protection scheme. Optional

Parameter type is SIDE—the role the unit is playing in the protection group

PROT

The entity is a protection unit in the protection group

WORK

The entity is a working unit in the protection group

STATUS

Port status in a Y-cable protection scheme. Optional

Parameter type is STATUS—the status of the unit in the protection pair

ACT

The entity is the active unit in the shelf

NA

Status is unavailable

STBY

The entity is the standby unit in the shelf

LINKRATE

The actual rate running on the Fibre Channel port. It can differ from the payload type provisioned

Parameter type is LINKRATE—the link rate on a Fibre Channel port

1GFC

The rate is 1 G Fibre Channel

1GFICON

The rate is 1 G FICON

2GFC

The rate is 2 G Fibre Channel

2GFICON

The rate is 2 G FICON

UNKNOWN

The rate is unknown

UNPLUGGED

The SFP is not plugged into the Fibre Channel port so the link rate cannot be detected

LINKSTATE

Link state

Parameter type is DIRN—specifies the discriminating level for the requested monitored parameter

DN

Monitored parameter with values equal to or greater than the level of LEV will be reported

UP

Monitored parameter with values equal or less than the value of LEV will be reported

LINKRCVRY

Link recovery

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

DISTEXTN

Distance extension. Optional

Parameter type is DISTANCE_EXTENSION—distance extension

B2B

Buffer to buffer flow control

NONE

No distance extension

LINKCREDITS

Number of link credits. Integer. Optional

MFS

Maximum frame size. Integer. Optional

ENCAP

Frame encapsulation type. Optional

Parameter type is ENCAP—frame encapsulation type

GFP_F

GFP frame mode

GFP_T

GFP transparent mode

HDLC

HDLC frame mode

HDLC_LEX

HDLC LAN extension frame mode

HDLC_X86

HDLC X.86 frame mode

NAME

Identifies the port name. String. Optional

SOAK

Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. Integer. Optional

SOAKLEFT

Time remaining for the transition from Locked-AutomaticInService to Unlocked measured in 1 minute intervals. The format is HH-MM where HH ranges from 00 to 48 and MM ranges from 00 to 59. Optional
Rules for <SOAKLEFT> are as follows:

When the port is in Locked, Locked_Maintenance or Unlocked state, the parameter will not appear.

When the port is in Locked_AutomaticInService, but the countdown has not started due to fault signal the value will be SOAKLEFT=NOT-STARTED.

When the port is in Locked_AutomaticInService state and the countdown has started the value will be shown in HH-MM format.

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1310

Wavelength 1310

1470

Wavelength 1470

1490

Wavelength 1490

1510

Wavelength 1510

1530

Wavelength 1530

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST_PSTQ

Primary state of the entity

Parameter type is PST_PSTQ—service state of the entity described by the primary state (PST) and a primary state qualifier (PSTQ)

Unlocked-Enabled

In service - normal

Locked-Disabled

Out of service - autonomous

Locked-Disabled

Out of service - autonomous and management

Locked-Enabled

Out of service - management

SST

Secondary state of the entity. Optional

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


21.2  RTRV-<MOD1FICONPAYLOAD>

Retrieve (1GFICON, 2 GFICON)

Usage Guidelines

This command returns Fibre-Channel-specific settings for ports that have been configured to carry FICON traffic using the ENT-FICON command. The MXP(P)-MR-2.5G card only supports the GFP-T frame type.

See Table 27-1 on page 27-1 for supported modifiers by platform.

Category

Ports

Security

Retrieve

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<STM_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<STM_TYPE>

ED-ALS

ED-DS3I

ED-E1/ED-E3/ED-E4

ED-FAC

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<STM_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-STM1E

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<STM_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<STM_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<STM_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD2DWDMPAYLOAD>

RTRV-<STM_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS3I

RTRV-E1/RTRV-E3/RTRV-E4

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<STM_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<STM_TYPE>

RTRV-STM1E

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

RTRV-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>;

Input Example

RTRV-1GFICON:CISCO:FAC-1-1:123;

Input Parameters

Table 21-3 RTRV-<MOD1FICONPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16. Must not be null


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>:,,[<ROLE>],[<STATUS>]:[LINKRATE=<LINKRATE>],[LINKSTATE=<LINKSTATE>],
[LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTEXTN>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[ENCAP=<ENCAP>],[NAME=<NAME>],
[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:
<PST_PSTQ>,<SST>"
;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-1-1:,,WORK,ACT:LINKRATE=1GFICON,LINKSTATE=UP,LINKRCVRY=Y,
DISTEXTN=NONE,LINKCREDITS=0,MFS=2148,ENCAP=GFP-T,NAME=\"FC PORT\",
SOAK=32,SOAKLEFT=\"12-25\",FREQ=1550,LOSSB=LR-1:LOCKED-ENABLED,
MAINTENANCE"
;

Output Parameters

Table 21-4 RTRV-<MOD1FICONPAYLOAD> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16

ROLE

The port role in a Y-cable protection scheme. Optional

Parameter type is SIDE—the role the unit is playing in the protection group

PROT

The entity is a protection unit in the protection group

WORK

The entity is a working unit in the protection group

STATUS

Port status in a Y-cable protection scheme. Optional

Parameter type is STATUS—the status of the unit in the protection pair

ACT

The entity is the active unit in the shelf

NA

Status is unavailable

STBY

The entity is the standby unit in the shelf

LINKRATE

The actual rate running on the Fibre Channel port. It can differ from the payload type provisioned

Parameter type is LINKRATE—the link rate on a Fibre Channel port

1GFC

The rate is 1 G Fibre Channel

1GFICON

The rate is 1 G FICON

2GFC

The rate is 2 G Fibre Channel

2GFICON

The rate is 2 G FICON

UNKNOWN

The rate is unknown

UNPLUGGED

The SFP is not plugged into the Fibre Channel port so the link rate cannot be detected

LINKSTATE

Link state

Parameter type is DIRN—specifies the discriminating level for the requested monitored parameter

DN

Monitored parameter with values equal to or greater than the level of LEV will be reported

UP

Monitored parameter with values equal or less than the value of LEV will be reported

LINKRCVRY

Link recovery

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

DISTEXTN

Distance extension. Optional

Parameter type is DISTANCE_EXTENSION—distance extension

B2B

Buffer to buffer flow control

NONE

No distance extension

LINKCREDITS

Number of link credits. Integer. Optional

MFS

Maximum frame size. Integer. Optional

ENCAP

Frame encapsulation type. Optional

Parameter type is ENCAP—frame encapsulation type

GFP_F

GFP frame mode

GFP_T

GFP transparent mode

HDLC

HDLC frame mode

HDLC_LEX

HDLC LAN extension frame mode

HDLC_X86

HDLC X.86 frame mode

NAME

Identifies the port name. String. Optional

SOAK

Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. Integer. Optional

SOAKLEFT

Time remaining for the transition from Locked-AutomaticInService to Unlocked measured in 1 minute intervals. The format is HH-MM where HH ranges from 00 to 48 and MM ranges from 00 to 59. Optional
Rules for <SOAKLEFT> are as follows:

When the port is in Locked, Locked_Maintenance or Unlocked state, the parameter will not appear.

When the port is in Locked_AutomaticInService, but the countdown has not started due to fault signal, the value will be SOAKLEFT=NOT-STARTED.

When the port is in Locked_AutomaticInService state and the countdown has started, the value will be shown in HH-MM format.

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1310

Wavelength 1310

1470

Wavelength 1470

1490

Wavelength 1490

1510

Wavelength 1510

1530

Wavelength 1530

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST_PSTQ

Primary state of the entity

Parameter type is PST_PSTQ—service state of the entity described by the primary state (PST) and a primary state qualifier (PSTQ)

Unlocked-Enabled

In service - normal

Locked-Disabled

Out of service - autonomous

Locked-Disabled

Out of service - autonomous and management

Locked-Enabled

Out of service - management

SST

Secondary state of the entity. Optional

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


21.3  RTRV-<MOD2DWDMPAYLOAD>

Retrieve (10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, ISC1, ISC3, PASSTHRU)

Usage Guidelines

This command retrieves the configuration parameter of a DWDM client.

See Table 27-1 on page 27-1 for supported modifiers by platform.

Category

DWDM

Security

Retrieve

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<STM_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<STM_TYPE>

ED-ALS

ED-DS3I

ED-E1/ED-E3/ED-E4

ED-FAC

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<STM_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-STM1E

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<STM_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<STM_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<STM_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<STM_TYPE>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS3I

RTRV-E1/RTRV-E3/RTRV-E4

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<STM_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<STM_TYPE>

RTRV-STM1E

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

RTRV-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];

Input Example

RTRV-HDTV:MILAN:FAC-1-1:100;

Input Parameters

Table 21-5 RTRV-<MOD2DWDMPAYLOAD> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16. Must not be null


Output Format

SID DATE TIME
M CTAG COMPLD
"<AIDUNIONID>,<AIDTYPE>:,,[<ROLE>],[<STATUS>]:[NAME=<NAME>],
[LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:<PSTPSTQ>,[<SST>]"
;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-1-1-1,HDTV:,,WORK,ACT:NAME=\"NY PORT\",LBCL=10.0,OPT=10.0,OPR=10.0,
FREQ=1550,LOSSB=LR-1:Unlocked-Disabled,AutomaticInService"
;

Output Parameters

Table 21-6 RTRV-<MOD2DWDMPAYLOAD> Output Parameters 

Parameter and Values
Description

AIDUNIONID

Access identifier from the "25.1.1  AidUnionId" section on page 25-6

AIDTYPE

A type of access identifier

Parameter type is MOD2DWDMPAYLOAD—payload types applicable to DWDM ports

10GFC

10 gigabit Fibre Channel payload

10GIGE

10 gigabit Ethernet

1GFC

1 gigabit Fibre Channel payload

1GFICON

1 gigabit FICON payload

2GFC

2 gigabit Fibre Channel payload

2GFICON

2 gigabit FICON payload

D1VIDEO

D1Video payload

DV6000

DV6000 payload

ETRCLO

ETRCLO payload

GIGE

Gigabit Ethernet payload

HDTV

HDTV payload

ISC1

ISC1 payload

ISC3

ISC3 payload

PASSTHRU

Any pass through (2R) payload

ROLE

The port role in a Y-cable protection scheme. Optional

Parameter type is SIDE—the role the unit has in the protection group

PROT

The entity is a protection unit in the protection group

WORK

The entity is a working unit in the protection group

STATUS

Port status in a Y-cable protection scheme. Optional

Parameter type is STATUS—the status of the unit in the protection pair

ACT

The entity is the active unit in the shelf

NA

Status is unavailable

STBY

The entity is the standby unit in the shelf

NAME

Identifies the port name. String. Optional

LBCL

Displays the current value of the laser current. Float. Optional

OPT

Displays the current value of the transmitted optical power. Float. Optional

OPR

Displays the current value of the received optical power. Float. Optional

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1310

Wavelength 1310

1470

Wavelength 1470

1490

Wavelength 1490

1510

Wavelength 1510

1530

Wavelength 1530

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST_PSTQ

Primary state of the entity

Parameter type is PST_PSTQ—service state of the entity described by the primary state (PST) and a primary state qualifier (PSTQ)

Unlocked-Enabled

In service - normal

Locked-Disabled

Out of service - autonomous

Locked-Disabled

Out of service - autonomous and management

Locked-Enabled

Out of service - management

SST

Secondary state of the entity. Optional

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


21.4  RTRV-<MOD_RING>

Retrieve Multiplex Section Shared Protection Ring

Usage Guidelines

This command retrieves the MS-SPRing information of the NE. A two-fiber or four-fiber MS-SPRing can be retrieved.

Output examples:

4F MS-SPRing

"MSSPR-N43AB::RINGID=N43AB,NODEID=3,MODE=4F,RVRTV=Y,RVTM=5.0,SRVRTV=Y,
SRVTM=5.0,EASTWORK=FAC-5-1,WESTWORK=FAC-6-1,EASTPROT=FAC-12-1,
WESTPROT=FAC-13-1"

2F MS-SPRing

"MSSPR-N12EF::RINGID=N12EF,NODEID=2,MODE=2F,RVRTV=Y,RVTM=5.0,
EASTWORK=FAC-5-1,WESTWORK=FAC-6-1"

Error conditions:

1. Only ALL, NULL, MSSPR-ALL, or MSSPR-RINGID is allowed for this command.

2. A NULL AID defaults to the AID ALL.

3. The list AID format is supported.

4. If the system fails on getting IOR, a SROF (Get IOR Failed) error message is returned.

5. If the AID is invalid, an IIAC (Invalid AID) error message is returned.

6. If the MS-SPRing does not exist, a SRQN (MSSPR Does Not Exist) error message is returned.

Category

MS-SPRing

Security

Retrieve

Related Commands

DLT-<MOD_RING>

ED-<MOD_RING>

ENT-<MOD_RING>

EX-SW-<STM_MSSPR>

RTRV-TRC-<STM_MSSPR>


Input Format

RTRV-<MOD_RING>:[<TID>]:[<AID>]:<CTAG>[::::];

Input Example

RTRV-MSSPR:PETALUMA:ALL:123;

Input Parameters

Table 21-7 RTRV-<MOD_RING> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.2  AidUnionId1" section on page 25-7. Identifies the MS-SPRing of the NE. Only ALL, null or a list of MSSPR-# in AID are allowed. A null value is equivalent to ALL


Output Format

SID DATE TIME
M CTAG COMPLD
"[<AID>]::[RINGID=<RINGID>],[NODEID=<NODEID>],[MODE=<MODE>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SRVRTV=<SRVRTV>],[SRVTM=<SRVTM>],
[EASTWORK=<EASTWORK>],[WESTWORK=<WESTWORK>],[EASTPROT=<EASTPROT>],
[WESTPROT=<WESTPROT>]"

;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"MSSPR-43::RINGID=43,NODEID=3,MODE=4F,RVRTV=Y,RVTM=5.0,
SRVRTV=Y,SRVTM=5.0,EASTWORK=FAC-5-1,WESTWORK=FAC-6-1,
EASTPROT=FAC-12-1,WESTPROT=FAC-13-1"
;

Output Parameters

Table 21-8 RTRV-<MOD_RING> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.2  AidUnionId1" section on page 25-7. Identifies the MS-SPRing of the NE. Optional

RINGID

The MS-SPRing ID of the NE up to six characters. Valid characters are A-Z and 0-9. String. Optional

NODEID

The MS-SPRing node ID of the NE. NODEID ranges from 0 to 31. String. Optional

MODE

Mode with which the command is to be implemented. Identifies the MS-SPRing mode; either two-fiber or four-fiber. Optional

Parameter type is MSSPR_MODE—MS-SPRing mode

2F

Two-fiber MS-SPRing

4F

Four-fiber MS-SPRing

RVRTV

Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time. RVTM is not allowed to be set while "RVRTV" is N

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

SRVRTV

The span revertive mode for four-fiber MS-SPRing only

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

SRVTM

The span revertive time for four-fiber MS-SPRing only. SRVTM is not allowed to be set while SRVRTV is N

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

EASTWORK

East working facility. AID from the "25.1.11  FACILITY" section on page 25-16

WESTWORK

West working facility. AID from the "25.1.11  FACILITY" section on page 25-16

EASTPROT

East protecting facility. AID from the "25.1.11  FACILITY" section on page 25-16

WESTPROT

West protecting facility. AID from the "25.1.11  FACILITY" section on page 25-16


21.5  RTRV-<PATH>

Retrieve (VC3, VC44C, VC38C, VC464C, VC48C, STS36C, VC4, VC416C, VC42C, VC43C, VC11, VC12)

Usage Guidelines

This command retrieves the attributes associated with an VC path.

See Table 27-1 on page 27-1 for supported modifiers by platform.

Supported AIDs are: ALL, SLOT-N (N=1,2,...,ALL), and VC-specific AIDs

The SFBER, SDBER, RVRTV, RVTM, SWPDIP, HOLDOFFTIMER, and SNCPPTHSTATE parameters only apply to SNCP.

The path trace message is a 64 character string including the terminating CR (carriage return) and LF (line feed) that is transported in the J1 byte of the SDH VC Path overhead.

The EXPTRC indicates the contents of the expected incoming path trace that are provisioned by the user in the ED-VC_PATH command. The TRC indicates the contents of the outgoing path trace message. The INCTRC indicates the contents of the incoming path trace message.

The path trace mode has three modes: OFF, MANUAL, and AUTO. The mode defaults to OFF. The MANUAL mode compares of the received string with the user entered expected string. The AUTO mode compares of the present received string with an expected string set to a previously received string. If there is a mismatch, the TIM-P alarm is raised. When the path trace mode is in OFF mode, there is no path trace processing, and all the alarm and state conditions are reset.

When the expected string is queried under the OFF path trace mode, the expected string is a copy of the provisioned string, or NULL. When an expected string is queried under the MANUAL path trace mode, the expected string is a copy of the user entered string. When an expected string is queried under the AUTO path trace mode, the expected string is either a copy of the acquired received string, or NULL if the string has not been acquired.

When the incoming string is queried under the OFF path trace mode, the incoming string is NULL. When an incoming string is queried under the MANUAL or AUTO path trace mode, the incoming string is either a copy of the received string, or NULL if the string has not been received.

J1 (EXPTRC) is implemented on the STM1, STM16AS, STM64, MRC-12 and STM64-XFP cards.


NoteAn optional parameter MSSPRPTHTYPE provides more options to retrieve J1/C2 of a particular MS-SPRing path. This field is valid only if the queried AID port has MS-SPRing. The MSSPRPTHTYPE defaults to "non-pca" path type if the MS-SPRing is switched, or defaults to all MS-SPRing path types if there is no MS-SPRing switching.

Sending this command while MSSPRPTHTYPE=PCA, whether there is MS-SPRing switch or not, the PCA path J1/C2 data will be returned (if there is PCA circuit on the AID). Sending this command with a VC AID without circuits and no MS-SPRing switched on the VC, will return and error message.

An optional output parameter MSSPRPTHSTATE is introduced into this command output. Each J1/C2 output data of this command will include the MS-SPRing path state information.

After the MS-SPRing switching, the J1/IPPM/C2 data can be retrieved over the protection path. Provisioning J1 trace string, trace mode, or threshold is not allowed on the protection path.

HOLDOFFTIMER is not specific to a path. Instead, it is applicable to the SNCP selector.

To retrieve either the cross-connect points or the test access points on the DS3i-N-12 card, the RTRV-VC3 command with the appropriate AID must be used.

For the selector path on an MS-SPRing, the SWPDIP path attribute is not editable and always in the ON state.


Category

Paths

Security

Retrieve

Related Commands

DLT-CRS-<PATH>

ED-<MOD_PATH>

ED-CRS-<PATH>

ED-NE-PATH

ENT-CRS-<PATH>

OPR-PROTNSW-<PATH>

RLS-PROTNSW-<PATH>

RTRV-CRS-<PATH>

RTRV-NE-PATH

RTRV-PROTNSW-<PATH>

RTRV-PTHTRC-<PATH>


Input Format

RTRV-<PATH>:[<TID>]:<AID>:<CTAG>:::[MSSPRPTHTYPE=<MSSPRPTHTYPE>][:];

Input Example

RTRV-VC4:FERNDALE:VC4-2-1-4:238:::MSSPRPTHTYPE=NON-PCA;

Input Parameters

Table 21-9 RTRV-<PATH> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.8  CrossConnectId1" section on page 25-11. Must not be null

MSSPRPTHTYPE

The MS-SPRing path type (only if the port is on the MS-SPRing). Defaults to NON-PCA. Applicable only to VC-level paths in SDH. A null value defaults to NON-PCA

Parameter type is MSSPR_PTH_TYPE—MS-SPRing path type only if the port is on the MS-SPRing

NON-PCA

The AID is on the working path, or the cross-connection card protection path

PCA

The AID is on the MS-SPRing PCA path


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>::[LEVEL=<LEVEL>],[SFBER=<SFBER>],[SDBER=<SDBER>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[SWPDIP=<SWPDIP>],[HOLDOFFTIMER=<HOLDOFFTIMER>],
[EXPTRC=<EXPTRC>],[TRC=<TRC>],[INCTRC=<INCTRC>],
[TRCMODE=<TRCMODE>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],
[SNCPPTHSTATE=<SNCPPTHSTATE>],[C2=<C2>],
[MSSPRPTHSTATE=<MSSPRPTHSTATE>]:<PST_PSTQ>,[<SSTQ>]"
;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"VC4-2-1-4::LEVEL=VC3,SFBER=1E-3,SDBER=1E-5,RVRTV=Y,RVTM=1.0,SWPDIP=Y,
HOLDOFFTIMER=2000,EXPTRC="EXPTRCSTRING",TRC="TRCSTRING",
INCTRC="INCTRCSTRING",TRCMODE=AUTO,TACC=8,TAPTYPE=DUAL,
SNCPPTHSTATE=ACT,C2=0X04,
MSSPRPTHSTATE=PROTPTHACT:UNLOCKED-DISABLED,AUTOMATICINSERVICE"
;

Output Parameters

Table 21-10 RTRV-<PATH> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.8  CrossConnectId1" section on page 25-11

LEVEL

The rate of the cross-connected channel. Applicable only to High-Order paths (VC4). Optional

Parameter type is PATH—modifier for path commands

VC3

Synchronous Transport Signal/Module Level-1 (51Mbs)

VC44C

Synchronous Transport Signal/Module Level-12 Concatenated (622Mbs)

VC38C

Synchronous Transport Signal/Module Level-18 Concatenated (933Mbps)

VC464C

Synchronous Transport Signal/Module Level-192 Concatenated (9952 Mbs)

VC48C

Synchronous Transport Signal/Module Level-24 Concatenated (1240 Mbs)

VC4

Synchronous Transport Signal/Module Signal Level-3 Concatenated (155 Mbs)

VC416C

Synchronous Transport Signal/Module Level-48 Concatenated (2488 Mbs)

VC42C

Synchronous Transport Signal/Module level-6 (310 Mbs)

VC43C

Synchronous Transport Signal/Module Level-9 Concatenated (465 Mbs)

VC12

Virtual Tributary 2. Virtual Channel 12

SFBER

An VC path signal failure threshold which only applies to SNCP. Applicable only to High-Order paths. Defaults to 1E-4. Optional

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

An VC path signal degrade threshold which only applies to SNCP. Applicable only High-Order paths. Defaults 1E-6. Optional

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

RVRTV

Revertive mode. Only applies to SNCP. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

RVTM

Revertive time. Only applies to SNCP

Parameter type is REVERTIVE_TIME—revertive time

0.5 to 12.0

Revertive time is 0.5 to 12.0 minutes

SWPDIP

Switch on PDI-P. Applicable only to VC-level paths (VCn). Optional

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

HOLDOFFTIMER

Hold off timer. Integer. Optional

EXPTRC

Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to VC-level paths (VCn). Defaults to NULL when SNCP path is created. String. Optional

TRC

The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. A null value defaults to the NE transmitting null characters (Hex 00). Applicable to VC-level paths (VCn). String. Optional

INCTRC

The incoming path trace message contents. INCTRC is any combination of 64 characters. Applicable only to VC-level paths in (VCn). Defaults to Null when a SNCP path is created. String. Optional

TRCMODE

Path trace mode. Applicable only to VC-level paths (VCn). Defaults to OFF when a SNCP path is created. Optional

Parameter type is TRCMODE—trace mode

AUTO

Use the previously received path trace string as the expected string (not applicable to MXP_2.5G_10G and TXP_MR_10G cards)

AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP detected

MAN

Use the provisioned expected string as the expected string

MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP detected

OFF

Turn off path trace capability. Nothing will be reported

TACC

Test access. Indicates whether the digroup being provisioned is to be used as a test access digroup. Defaults to N. Optional

TAPTYPE

TAP type. Optional

Parameter type is TAPTYPE—test access point type

DUAL

Dual FAD

SINGLE

Single FAD

SNCPPTHSTATE

Indicates whether a given AID is the working or standby path of a SNCP cross-connect. Optional

Parameter type is STATUS—status of the unit in the protection pair

ACT

The entity is the active unit in the shelf

NA

Status is unavailable

STBY

The entity is the standby unit in the shelf

C2

The c2 byte hex code. Applicable only to VC-level paths (VCn). Optional

Parameter type is C2_BYTE—c2 byte hex code

0X00

Unequipped

0X01

Equipped-Non Specific payload

0X02

VT-Structured VC-1 SPE

0X03

Locked VT mode

0X04

Asynchronous Mapping for DS3

0X12

Asynchronous Mapping for DS4NA

0X13

Mapping for ATM

0X14

Mapping for DQDB

0X15

Asynchronous Mapping for FDDI

0X16

HDLC-Over-SDH Mapping

0XE1

VT-structured VC4-1 SPE with 1VTx payload defect

0XE2

VT-structured VC4-1 SPE with 2VTx payload defects

0XE3

VT-structured VC4-1 SPE with 3VTx payload defects

0XE4

VT-structured VC4-1 SPE with 4VTx payload defects

0XE5

VT-structured VC4-1 SPE with 5VTx payload defects

0XE6

VT-structured VC4-1 SPE with 6VTx payload defects

0XE7

VT-structured VC4-1 SPE with 7VTx payload defects

0XE8

VT-structured VC4-1 SPE with 8VTx payload defects

0XE9

VT-structured VC4-1 SPE with 9VTx payload defects

0XEA

VT-structured VC4-1 SPE with 10VTx payload defects

0XEB

VT-structured VC4-1 SPE with 11VTx payload defects

0XEC

VT-structured VC4-1 SPE with 12VTx payload defects

0XED

VT-structured VC4-1 SPE with 13VTx payload defects

0XEE

VT-structured VC4-1 SPE with 14VTx payload defects

0XEF

VT-structured VC4-1 SPE with 15VTx payload defects

0XF0

VT-structured VC4-1 SPE with 16VTx payload defects

0XF1

VT-structured VC4-1 SPE with 17VTx payload defects

0XF2

VT-structured VC4-1 SPE with 18VTx payload defects

0XF3

VT-structured VC4-1 SPE with 19VTx payload defects

0XF4

VT-structured VC4-1 SPE with 20VTx payload defects

0XF5

VT-structured VC4-1 SPE with 21VTx payload defects

0XF6

VT-structured VC4-1 SPE with 22VTx payload defects

0XF7

VT-structured VC4-1 SPE with 23VTx payload defects

0XF8

VT-structured VC4-1 SPE with 24VTx payload defects

0XF9

VT-structured VC4-1 SPE with 25VTx payload defects

0XFA

VT-structured VC4-1 SPE with 26VTx payload defects

0XFB

VT-structured VC4-1 SPE with 27VTx payload defects

0XFC

VT-structured VC4-1 SPE with 28VTx payload defects

0XFE

O.181 Test Signal (TSS1 to TSS3) Mapping

0XFF

Reserved, however, C2 is 0XFF if AIS-L is being generated by an optical card or cross-connect downstream

MSSPRPTHSTATE

The MS-SPRing path state only if the port is on the MS-SPRing. Applicable only to VC-level paths in SDH (VCn). Optional

Parameter type is MSSPR_PTH_STATE—the MS-SPRing path state only if the port is on the MS-SPRing

PCAPTHACT

Indicates the MS-SPRing un-switched and its PCA path is in the active state

PCAPTHSTB

Indicates the MS-SPRing switched and its PCA path is in the standby state

PROTPTHACT

Indicates the MS-SPRing switched and its protection path is in the active state

WKGPTHACT

Indicates the MS-SPRing un-switched and its working path is in the active state

WKGPTHSTB

Indicates the MS-SPRing switched and its working path is in the standby state

PST_PSTQ

Admin state in the PST_PSTQ format

Parameter type is PST_PSTQ—service state of the entity described by the primary state (SST) and a primary state qualifier (PSTQ)

Unlocked-Enabled

In service - normal

Locked-Disabled

Out of service - autonomous

Locked-Disabled

Out of service - autonomous and management

Locked-Enabled

Out of service - management

SSTQ

Secondary state of the entity. Optional

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


21.6  RTRV-<STM_TYPE>

Retrieve (STM1, STM4, STM16, STM64)

Usage Guidelines

This command retrieves the attributes (such as, service parameters) and the state of an STM facility.

See Table 27-1 on page 27-1 for supported modifiers by platform.

Both RINGID and MSSPRTYPE identify the STM port connected with a MS-SPRing. These attributes are only presented for the STM4, STM16, STM64 ports within a MS-SPRing connection. The RTRV-<MOD_RING> command with the AID MSSPR-RINGID, can provide more information on this MS-SPRing.


Note This command does not show the WVLEN attribute if the STM port has zero value on WVLEN.


UNI-C DCC provisioning notes:

1. The attributes DCC(Y/N) and mode (SONET/SDH) remain the same in the ED/RTRV-STM commands when the DCC is used for UNI-C, in which case the port attribute UNIC is enabled (UNIC=Y).

2. UNI-C DCC termination cannot be deleted by the regular DCC deprovisioning command.

3. If the DCC is created under regular SDH provisioning, and this port is used by UNI-C, the port is converted as an UNI-C DCC automatically.

4. Deprovisioning UNI-C IF/IB IPCC will free up DCC termination automatically.

5. The parameters ALSMODE, ALSRCINT, and ALSRCPW are only applicable for STM1-8, STM64 and STM16ELR cards.

6. SSMRCV will display the quality of the individual port.

7. J0 Support (EXPTRC, TRC, TRCMODE and TRCFORMAT parameters) are supported by: DWDM cards with an STM payload, the MRC-12 card and the STM64-XFP card. J0 is not supported by STM1-8, STM4, STM16, STM64 and other SDH optical cards.

Category

MS-SPRing

Security

Retrieve

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<STM_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<STM_TYPE>

ED-ALS

ED-DS3I

ED-E1/ED-E3/ED-E4

ED-FAC

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<STM_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-STM1E

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<STM_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<STM_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<STM_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2FICONPAYLOAD>

RTRV-10GIGE

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS3I

RTRV-E1/RTRV-E3/RTRV-E4

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<STM_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<STM_TYPE>

RTRV-STM1E

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

RTRV-<STM_TYPE>:[<TID>]:<AID>:<CTAG>[::::];

Input Example

RTRV-STM16:PENNGROVE:FAC-6-1:236;

Input Parameters

Table 21-11 RTRV-<STM_TYPE> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16. Must not be null


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>:,,[<ROLE>],[<STATUS>]:[DCC=<DCC>],[AREA=<AREA>],[TMGREF=<TMGREF>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[WVLEN=<WVLEN>],
[RINGID=<RINGID>],[MSSPRTYPE=<MSSPRTYPE>],[MUX=<MUX>],[UNIC=<UNIC>],
[CCID=<CCID>],[NBRIX=<NBRIX>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],
[SSMRCV=<SSMRCV>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>],
[LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],
[SENDDUSFF=<SENDDUSFF>],[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>],[FOREIGNFEND=<FOREIGNFEND>],
[FOREIGNIPADDRESS=<FOREIGNIPADDRESS>],:<PSTPSTQ>,[<SSTQ>]"
;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-6-1:,,WORK,ACT:DCC=Y,AREA=10.92.63.1,TMGREF=N,SYNCMSG=N,SENDDUS=N,
PJMON=48,SFBER=1E-4,SDBER=1E-6,MODE=SDH,WVLEN=1310.00,RINGID=43,
MSSPRTYPE=WESTWORK,MUX=E2,UNIC=Y,CCID=8,NBRIX=2,SOAK=52,
SOAKLEFT=12-25,SSMRCV=STU,OSPF=Y,LDCC=Y,
NAME=\"STM PORT\",LBCL=10.0,OPT=10.0,OPR=10.0,
EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,TRCFORMAT=16-BYTE,ADMSSM=PRS,
SENDDUSFF=N,AISONLPBK=AIS_ON_LPBK_ALL,FREQ=1550,LOSSB=LR-1,
FOREIGNFEND=Y,FOREIGNIPADDRESS=10.92.63.44,UNLOCKED-DISABLED,
AUTOMATICINSERVICE"
;

Output Parameters

Table 21-12 RTRV-<STM_TYPE> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16

ROLE

An STM port role. Optional

Parameter type is SIDE—the role the unit is playing in the protection group

PROT

The entity is a protection unit in the protection group

WORK

The entity is a working unit in the protection group

STATUS

An STM port status. Optional

Parameter type is STATUS—the status of the unit in the protection pair

ACT

The entity is the active unit in the shelf

NA

Status is unavailable

STBY

The entity is the standby unit in the shelf

DCC

Indicates whether or not the section DCC is to be used. Optional

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

AREA

Area ID. Shows up only if the DCC is enabled. String. Optional

TMGREF

The termination to be used, whether primary or secondary. Identifies if an STM port has a timing reference. Defaults to N. Optional

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

SYNCMSG

Synchronization status message

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

SENDDUS

The facility will send the DUS (Don't use for Synchronization) value in 0x0f bits pattern as the synchronization status message for that facility. Defaults to N. Optional

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

PJMON

(Optional) Identifies an STM port PJMON. PJMON is an integer. It defaults to 0 (zero). Set a valid VC4 number of the optical port.

Note The PJMON number displayed in TL1 interface does not correspond to the PJVC4MON number in CTC, but instead corresponds to the VC4 number of the optical port.

SFBER

An STM port signal failure threshold. Defaults to 1E-4. Optional

Parameter type is SF_BER—the threshold for declaring signal failure on a facility or path

1E-3

SFBER is 1E-3

1E-4

SFBER is 1E-4

1E-5

SFBER is 1E-5

SDBER

An STM port signal degrade threshold. Defaults 1E-7. Optional

Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path

1E-5

SDBER is 1E-5

1E-6

SDBER is 1E-6

1E-7

SDBER is 1E-7

1E-8

SDBER is 1E-8

1E-9

SDBER is 1E-9

MODE

STM port mode. Defaults to SDH. Optional

Parameter type is OPTICAL_MODE—the facility's optical mode

SDH

SDH/ETSI optical mode using European/International format

SONET

SONET/ANSI optical mode using the American format

WVLEN

An STM port wavelength in nanometer. For example, WVLEN=1310.00 means it operates at 1310 nm in the DWDM application. Float. Optional

RINGID

The MS-SPRing RINGID with which the port is connected. RINGID ranges from 0 to 9999. Integer. Optional

MSSPRTYPE

The MS-SPRing type with which the port is connected. Optional

Parameter type is MSSPR_TYPE—MS-SPRing type of an STM port

EASTPROT

The STM port is an east protecting port

EASTWORK

The STM port is an east working port

WESTPROT

The STM port is an west protecting port

WESTWORK

The STM port is an west working port

MUX

MS-SPRing extension byte. Optional

Parameter type is MUX_TYPE—MS-SPRing extension byte

E2

E2 byte (orderwire)

F1

F1 byte (user)

K3

K3 byte

Z2

Z2 byte

SOAK

Locked-AutomaticInService to Unlocked transition soak time as measured in 15-minute intervals. Integer. Optional

SOAKLEFT

Time remaining for the transition from Locked-AutomaticInService to Unlocked measured in 1 minute intervals. The format is HH-MM where HH ranges from 00 to 48 and MM ranges from 00 to 59. Optional
Rules for <SOAKLEFT> are as follows:

When the port is in Locked, Locked_Maintenance or Unlocked state, the parameter will not appear.

When the port is in Locked_AutomaticInService, but the countdown has not started due to fault signal the value will be SOAKLEFT=NOT-STARTED.

When the port is in Locked_AutomaticInService state and the countdown has started the value will be shown in HH-MM format.

SSMRCV

Displays the quality of the individual port. Optional

Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SDH

DUS_SDH

Do Not Use For Synchronization

G811

G811 Standard

RES_SDH

Reserved For Network Synchronization Use

G812T

G812T Standard

STU_SDH

Synchronized, Traceability Unknown

G812TL

G812TL Standard

SETS

Synchronous Equipment Timing Source

OSPF

The Open Shortest Path First discovery. Optional

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

LDCC

The line DCC connection on the port. Optional

Parameter type is EXT_RING—indicates if the ring supports the extended K1/K2/K3 protocol

N

The ring does not support the extended K1/K2/K3 protocol

Y

The ring does support the extended K1/K2/K3 protocol

NAME

Name. String. Optional

LBCL

Displays the current value of the laser current. Float. Optional

OPT

Displays the current value of the transmitted optical power. OPT is only displayed for DWDM cards. Float. Optional

OPR

Received optical power. Float

EXPTRC

Expected path trace content. String. Optional

TRC

Path trace message to be transmitted. String. Optional

TRCMODE

Path trace mode. Applicable only to VC-level Paths in SDH (VCn). Defaults to the OFF mode. Optional

Parameter type is TRCMODE—trace mode

AUTO

Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards

AUTO-NO-AIS

Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected

MAN

Use the provisioned expected string as the expected string

MAN-NO-AIS

Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected

OFF

Turn off path trace capability. Nothing will be reported

TRCFORMAT

Trace message size. Optional

 

Parameter type is TRCFORMAT—trace format

1-BYTE

1 byte trace message

16-BYTE

16 byte trace message

64-BYTE

64 byte trace message

Y

Enable an attribute

ADMSSM

SSM selectable value. Only displayed when SSM is disabled. Optional

 

Parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL—clock source quality level for SDH

DUS_SDH

Do Not Use For Synchronization

G811

G811 Standard

RES_SDH

Reserved For Network Synchronization Use

G812T

G812T Standard

STU_SDH

Synchronized, Traceability Unknown

G812TL

G812TL Standard

SETS

Synchronous Equipment Timing Source

SENDDUSFF

Indicates that the facility will send the DUS (Don't use for synchronization) value in 0xff bits pattern as the synchronization status message for that facility. Defaults to N. Optional

 

Parameter type is ON_OFF—disable or enable an attribute

N

Disable an attribute

Y

Enable an attribute

AISONLPBK

Parameter type is AIS_ON_LPBK—indicates if AIS should be sent on loopback

AIS_ONLPBK_FACILITY

AIS is sent on facility loopback

AIS_ON_LPBK_ALL

AIS is sent on all loopbacks

AIS_ON_LPBK_OFF

AIS is not sent on loopback

AIS_ON_LPBK_TERMINAL

AIS is sent on terminal loopback

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1310

Wavelength 1310

1470

Wavelength 1470

1490

Wavelength 1490

1510

Wavelength 1510

1530

Wavelength 1530

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

FOREIGNFEND

Indicates whether the far-end NE on the DCC is a foreign NE

Parameter type is ON_OFF—disable or enabled an attribute

N

Disable an attribute

Y

Enable an attribute

FOREIGNIP

The IP address of the far-end NE on the DCC. Used only if FOREIGNFEND is Y. String

PST_PSTQ

Admin state in the PST_PSTQ format

 

Parameter type is PST_PSTQ—service state of the entity described by the primary state (SST) and a primary state qualifier (PSTQ)

Unlocked-Enabled

In service - normal

Locked-Disabled

Out of service - autonomous

Locked-Disabled

Out of service - autonomous and management

Locked-Enabled

Out of service - management

SSTQ

Secondary state of the entity. Optional

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


21.7  RTRV-10GIGE

Retrieve 10GIGE

Usage Guidelines

This command retrieves the 10 Gbps-specific parameters for a port that has been configured to support the gigabyte Ethernet payload with the ENT-10GIGE command.

Category

Ports

Security

Retrieve

Related Commands

DLT-<MOD1PAYLOAD>

DLT-FFP-<MOD2DWDMPAYLOAD>

DLT-FFP-<STM_TYPE>

ED-<MOD1FCPAYLOAD>

ED-<MOD1FICONPAYLOAD>

ED-<MOD2DWDMPAYLOAD>

ED-<STM_TYPE>

ED-ALS

ED-DS3I

ED-E1/ED-E3/ED-E4

ED-FAC

ED-FFP-<MOD2DWDMPAYLOAD>

ED-FFP-<STM_TYPE>

ED-FSTE

ED-G1000

ED-GFP

ED-HDLC

ED-STM1E

ENT-<MOD1PAYLOAD>

ENT-FFP-<MOD2DWDMPAYLOAD>

ENT-FFP-<STM_TYPE>

INIT-REG-<MOD2>

OPR-ALS

OPR-LPBK-<MOD2>

OPR-PROTNSW-<MOD2DWDMPAYLOAD>

OPR-PROTNSW-<STM_TYPE>

REPT PM <MOD2>

RLS-LPBK-<MOD2>

RLS-PROTNSW-<MOD2DWDMPAYLOAD>

RLS-PROTNSW-<STM_TYPE>

RMV-<MOD2>

RST-<MOD2>

RTRV-<MOD1FCPAYLOAD>

RTRV-<MOD1FICONPAYLOAD>

RTRV-<MOD2FICONPAYLOAD>

RTRV-<STM_TYPE>

RTRV-ALMTH-<MOD2>

RTRV-ALS

RTRV-DS3I

RTRV-E1/RTRV-E3/RTRV-E4

RTRV-FAC

RTRV-FFP-<MOD2DWDMPAYLOAD>

RTRV-FFP-<STM_TYPE>

RTRV-FSTE

RTRV-G1000

RTRV-GFP

RTRV-GIGE

RTRV-HDLC

RTRV-PM-<MOD2>

RTRV-PMSCHED-<MOD2>

RTRV-POS

RTRV-PROTNSW-<MOD2DWDMPAYLOAD>

RTRV-PROTNSW-<STM_TYPE>

RTRV-STM1E

RTRV-TH-<MOD2>

SCHED-PMREPT-<MOD2>

SET-ALMTH-<MOD2>

SET-TH-<MOD2>


Input Format

RTRV-10GIGE:[<TID>]:<AID>:<CTAG>[::::];

Input Example

RTRV-10GIGE:TID:FAC-1-1:100;

Input Parameters

Table 21-13 RTRV-10GIGE Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16. Must not be null


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>:,,[<ROLE>],[<STATUS>]:[NAME=<NAME>],[MACADDR=<MACADDR>],
[LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:
<PSTPSTQ>,[<SST>]"
;

Output Examples

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-6-1:,,WORK,ACT:NAME=\"NY PORT\",MACADDR=00-0E-AA-BB-CC-FF,LBCL=10.0,
OPT=10.0,OPR=10.0,FREQ=1550,LOSSB=SX:Unlocked-Disabled,AutomaticInService"
;

Output Parameters

Table 21-14 RTRV-10GIGE Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.11  FACILITY" section on page 25-16

ROLE

The port role in a Y-cable protection scheme. Optional

Parameter type is SIDE—the role the unit is playing in the protection group

PROT

The entity is a protection unit in the protection group

WORK

The entity is a working unit in the protection group

STATUS

Port status in a Y-cable protection scheme. Optional

Parameter type is STATUS—the status of the unit in the protection pair

ACT

The entity is the active unit in the shelf

NA

Status is unavailable

STBY

The entity is the standby unit in the shelf

NAME

Port name. String. Optional

MACADDR

The MAC address for the 10 gigabyte Ethernet payload. String. Optional

LBCL

Displays the current value of the laser current. Float. Optional

OPT

Displays the current value of the transmitted optical power. Float. Optional

OPR

Displays the current value of the received optical power. Float. Optional

FREQ

Parameter type is OPTICAL-WLEN—optical wavelength

1310

Wavelength 1310

1470

Wavelength 1470

1490

Wavelength 1490

1510

Wavelength 1510

1530

Wavelength 1530

1530.33

Wavelength 1

1531.12

Wavelength 2

1531.90

Wavelength 3

1532.68

Wavelength 4

1534.25

Wavelength 5

1535.04

Wavelength 6

1535.82

Wavelength 7

1536.61

Wavelength 8

1538.19

Wavelength 9

1538.98

Wavelength 10

1539.77

Wavelength 11

1540.56

Wavelength 12

1542.14

Wavelength 13

1542.94

Wavelength 14

1543.73

Wavelength 15

1544.53

Wavelength 16

1546.12

Wavelength 17

1546.92

Wavelength 18

1547.72

Wavelength 19

1548.51

Wavelength 20

1550.12

Wavelength 21

1550.92

Wavelength 22

1551.72

Wavelength 23

1552.52

Wavelength 24

1554.13

Wavelength 25

1554.94

Wavelength 26

1555.75

Wavelength 27

1556.55

Wavelength 28

1558.17

Wavelength 29

1558.98

Wavelength 30

1559.79

Wavelength 31

1560.61

Wavelength 32

USE-TWL1

Use Tunable Wavelength 1

LOSSB

Parameter type is REACH—reach values

AUTOPROV

Autoprovisioning

CX

Reach CX

DX

Reach DX

HX

Reach HX

I1

Reach I1

IR-1

Reach IR-1

IR-2

Reach IR-2

L1

Reach L1

L2

Reach L2

L3

Reach L3

LR-1

Reach LR-1

LR-2

Reach LR-2

LR-3

Reach LR-3

LX

Reach LX

S1

Reach S1

S2

Reach S2

SR

Reach SR

SR-1

Reach SR-1

SX

Reach SX

T

Reach T

VX

Reach VX

ZX

Reach ZX

PST_PSTQ

Admin state in the PST_PSTQ format

Parameter type is PST_PSTQ—service state of the entity described by the primary state (SST) and a primary state qualifier (PSTQ)

Unlocked-Enabled

In service - normal

Locked-Disabled

Out of service - autonomous

Locked-Disabled

Out of service - autonomous and management

Locked-Enabled

Out of service - management

SST

Secondary state of the entity. Optional

Parameter type is SST—provides additional information pertaining to PST and PSTQ

AutomaticInService

Automatic in service

Disabled

Disabled

Loopback

Loopback

MismatchofEquipmentAlarm

Mismatch of equipment and attributes

Maintenance

Maintenance mode

OutOfGroup

Out of group

SoftwareDownload

Software downloading

Unassigned

Unassigned

NotInstalled

Unequipped


21.8  RTRV-ALM-<MOD2ALM>

Retrieve Alarm (1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, DS3I, E1, E100, E1000, E3, E4, FSTE, G1000, GFPOS, GIGE, STM4, STM64, STM1, STM16, OCH, OMS, OTS, POS, STM1E, VC3, VC44C, VC38C, VC464C, VC48C, STS36C, VC4, VC416C, VC42C, VC43C, UDCDCC, UDCF, VCG, VC11, VC12, WLEN)

Usage Guidelines

This command retrieves and sends the current status of alarm conditions. The alarm condition or severity to be retrieved can be specified by using the input parameters as a filter.

See Table 27-1 on page 27-1 for supported modifiers by platform.


Note VT1-n-n-n replaces PS_VC12-n-n-n for the VC12 alarm AID.



Note The [<AIDTYPE>] shows VC3 for VC alarms.


Category

Fault

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Input Format

RTRV-ALM-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];

Input Example

RTRV-ALM-STM4:ELDRIDGE:FAC-5-1:225::MN,SD,SA;

Input Parameters

Table 21-15 RTRV-ALM-<MOD2ALM> Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.1  AidUnionId" section on page 25-6. Must not be null

NTFCNCDE

Two-letter notification code. A null value is equivalent to ALL

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event. A null value is equivalent to ALL

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See the Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service. A null value is equivalent to ALL

NSA

The condition is non-service affecting

SA

The condition is service affecting


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,[<OCRDAT>],
[<OCRTM>],,:[<DESC>]"

;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"FAC-5-1,STM4:MJ,SD,SA,09-05,12-30-20,,:\"BER AT SIGNAL DEGRADE LEVEL\","
;

Output Parameters

Table 21-16 RTRV-ALM-<MOD2ALM> Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1  ALL" section on page 25-1

AIDTYPE

Type of access identifier. Optional

Parameter type is MOD2ALM—alarm type

1GFC

1 Gigabit Fibre Channel alarm

1GFICON

1 Gigabit FICON alarm

2GFC

2 Gigabit Fibre Channel alarm

2GFICON

2 Gigabit FICON alarm

CLNT

Client facility for MXP/TXP cards

DS3I

DS3I alarm

E1

E1alarm

E100

E100 alarm

E1000

E1000 alarm

E3

E3alarm

E4

E4 frame. Only applicable to STM1E port 9 through 12 when it is in E4-FRAMED or E4-UNFRAMED mode

FSTE

Fast Ethernet Port alarm

G1000

G1000 alarm

GFPOS

Generic framing protocol over packet over SDH virtual port alarm

GIGE

GIG Ethernet port alarm

STM1

STM1 alarm

STM4

STM4 alarm

STM16

STM16 alarm

STM64

STM64 alarm

OCH

Optical channel

OMS

Optical Multiplex Section

OTS

Optical Transport Section

POS

POS port alarm

STM1E

STM1E facility. Only applicable to the STM1E facility (when it is in STM1E mode) of SDH STM1E-12 card

VC11

VC11 alarm

VC12

VC12 alarm

VC3

VC3 alarm

VC38C

VC38C alarm

VC44C

VC44C alarm

VC464C

VC464C alarm

VC48C

VC48C alarm

VC4

VC4 alarm

VC416C

VC416C alarm

VC42C

VC42C alarm

VC43C

VC43C alarm

UDCDCC

UDCDCC alarm

UDCF

UCDF alarm

VCG

Virtual Concatenation Group alarm

WLEN

Wavelength Path Provisioning

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether the problem is reported (that is, whether it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See the Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

NSA

The condition is non-service affecting

SA

The condition is service affecting

OCRDAT

Date when the specific event or violation occurred. Optional

OCRTM

Time when the specific event or violation occurred. Optional

DESC

The condition description


21.9  RTRV-ALM-ALL

Retrieve Alarm All

Usage Guidelines

This command retrieves and sends the current status of all active alarm conditions. The alarm condition or severity to be retrieved is specified using the input parameters as a filter.

To retrieve all the NE alarms, issue all of the following commands:

RTRV-ALM-ALL
RTRV-ALM-BITS
RTRV-ALM-ENV
RTRV-ALM-SYNCN

Category

Fault

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Input Format

RTRV-ALM-ALL:[<TID>]:[<AID>]:<CTAG>::[<NTFCNCDE>],
[<CONDITION>],[<SRVEFF>][,,,];

Input Example

RTRV-ALM-ALL:COTATI:ALL:229::MN,PWRRESTART,NSA;

Input Parameters

Table 21-17 RTRV-ALM-ALL Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1  ALL" section on page 25-1. A null value is equivalent to ALL. String

NTFCNCDE

Two-letter notification code. A null value is equivalent to ALL

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDITION

The type of alarm condition. A null value is equivalent to ALL

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service. A null value is equivalent to ALL

NSA

The condition is non-service affecting

SA

The condition is service affecting


Output Format

SID DATE TIME
M CTAG COMPLD
"[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,<OCRDAT>,
<OCRTM>,,:[<DESC>],[<AIDDET>]"

;

Output Examples

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"SLOT-2,EQPT:MN,PWRRESTART,NSA,08-01,14-25-59,,:\"POWER FAIL RESTART\",E1-N-14"
;

Output Parameters

Table 21-18 RTRV-ALM-ALL Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1  ALL" section on page 25-1. Optional

AIDTYPE

Type of facility, link or other addressable entity targeted by the message. Optional

Parameter type is MOD2B—alarm type

1GFC

1 Gigabit Fibre Channel alarm

1GFICON

1 Gigabit FICON alarm

2GFC

2 Gigabit Fibre Channel alarm

2GFICON

2 Gigabit FICON alarm

BITS

BITS alarm

CLNT

Client facility for MXP/TXP cards

COM

Common alarm

DS3I

DS3I alarm

E1

E1 alarm

E100

E100 alarm

E1000

E1000 alarm

E3

E3 alarm

E4

E4 alarm

ENV

ENV alarm

EQPT

EQPT alarm

FSTE

Fast Ethernet Port alarm

G1000

G1000 alarm

GIGE

GIG Ethernet port alarm

STM1

STM1 alarm

STM4

STM4 alarm

STM16

STM16 alarm

STM64

STM64 alarm

OCH

Optical channel

OMS

Optical Multiplex Section

OTS

Optical Transport Section

POS

POS port alarm

STM1E

STM1E alarm

VC11

VC11 alarm

VC12

VC12 alarm

VC3

VC3 alarm

VC44C

VC44C alarm

VC38C

VC38C alarm

VC464C

VC464C alarm

VC48C

VC48C alarm

VC4

VC4 alarm

VC416C

VC416C alarm

VC42C

VC42C alarm

VC43C

VC43C alarm

SYNCN

SYNCN alarm

TCC

TCC alarm

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

NSA

The condition is non-service affecting

SA

The condition is service affecting

OCRDAT

Date

OCRTM

Time

DESC

A condition description. String. Optional

AIDDET

AIDDET uses the same addressing rules as the AID, but specifies AID type and additional details about the entity being managed. The supplementary equipment identification. Optional


21.10  RTRV-ALM-BITS

Retrieve Alarm Building Integrated Timing Supply

Usage Guidelines

This command retrieves and sends the current status of alarm conditions associated with the BITS facility. The alarm condition or severity retrieved is specified using the input parameters as a filter.

Category

Synchronization

Security

Retrieve

Related Commands

CLR-COND-SECU

ED-BITS

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Input Format

RTRV-ALM-BITS:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],[<SRVEFF>][,,,];

Input Example

RTRV-ALM-BITS:ELVERANO:BITS-1:228::CR,LOS,SA;

Input Parameters

Table 21-19 RTRV-ALM-BITS Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.4  BITS" section on page 25-8. Must not be null

NTFCNCDE

Two-letter notification code. A null value is equivalent to ALL

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

The condition type for an alarm or reported event. A null value is equivalent to ALL

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service. A null value is equivalent to ALL

NSA

The condition is non-service affecting

SA

The condition is service affecting


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,
[<OCRDAT>],[<OCRTM>],,:[<DESC>]"

;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"BITS-1,BITS:CR,LOS,SA,08-01,14-25-59,,:\"LOSS OF SIGNAL\","
;

Output Parameters

Table 21-20 RTRV-ALM-BITS Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.4  BITS" section on page 25-8. Optional

AIDTYPE

Type of facility, link or other addressable entity targeted by the message. Optional

Parameter type is MOD2B—alarm type

1GFC

1 Gigabit Fibre Channel alarm

1GFICON

1 Gigabit FICON alarm

2GFC

2 Gigabit Fibre Channel alarm

2GFICON

2 Gigabit FICON alarm

BITS

BITS alarm

CLNT

Client facility for MXP/TXP cards

COM

Common alarm

DS3I

DS3I alarm

E1

E1 alarm

E100

E100 alarm

E1000

E1000 alarm

E3

E3 alarm

E4

E4 alarm

ENV

ENV alarm

EQPT

EQPT alarm

FSTE

Fast Ethernet Port alarm

G1000

G1000 alarm

GIGE

GIG Ethernet port alarm

STM1

STM1 alarm

STM4

STM4 alarm

STM16

STM16 alarm

STM64

STM64 alarm

OCH

Optical channel

OMS

Optical Multiplex Section

OTS

Optical Transport Section

POS

POS port alarm

STM1E

STM1E alarm

VC11

VC11 alarm

VC12

VC12 alarm

VC3

VC3 alarm

VC44C

VC44C alarm

VC38C

VC38C alarm

VC464C

VC464C alarm

VC48C

VC48C alarm

VC4

VC4 alarm

VC416C

VC416C alarm

VC42C

VC42C alarm

VC43C

VC43C alarm

SYNCN

SYNCN alarm

TCC

TCC alarm

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

NSA

The condition is non-service affecting

SA

The condition is service affecting

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

A condition description. String. Optional


21.11  RTRV-ALM-ENV

Retrieve Alarm Environment

Usage Guidelines

This command retrieves the environmental alarms.

Category

Environment

Security

Retrieve

Related Commands

CLR-COND-SECU

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-EQPT

RTRV-ALM-SYNCN

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN


Input Format

RTRV-ALM-ENV:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<ALMTYPE>];

Input Example

RTRV-ALM-ENV:CISCO:ENV-IN-1:123::MJ,OPENDR;

Input Parameters

Table 21-21 RTRV-ALM-ENV Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.9  ENV" section on page 25-14. Must not be null

Note For RTRV-ALM-ENV, only ENV-IN-{1-4} is a valid AID. ENV-OUT-{1,6} is not a valid AID for RTRV-ALM-ENV.

NTFCNCDE

Two-letter notification code. A null value is equivalent to ALL

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

ALMTYPE

The alarm type for the environmental alarm. A null value is equivalent to ALL

Parameter type is ENV_ALM—environmental alarm types

AIRCOMPR

Air compressor failure

AIRCOND

Air conditioning failure

AIRDRYR

Air dryer failure

BATDSCHRG

Battery discharging

BATTERY

Battery failure

CLFAN

Cooling fan failure

CPMAJOR

Centralized power major failure

CPMINOR

Centralized power minor failure

ENGINE

Engine failure

ENGOPRG

Engine operating

ENGTRANS

Standby engine transfer

EXPLGS

Explosive gas

FIRDETR

Fire detector failure

FIRE

Fire

FLOOD

Flood

FUELLEAK

Fuel leak

FUSE

Fuse failure

GASALARM

Explosive gas, toxic gas, ventilation fail or gas monitor fail

HATCH

CEV hatch fail

GEN

Generator failure

HIAIR

High air flow

HIHUM

High humidity

HITEMP

High temperature

HIWTR

High water

INTRUDER

Intrusion

LEVELCON

Level converter

LVDADSL

Secondary ADSL low voltage disconnect

LVDBYPAS

Low voltage disconnected bypass

LWBATVG

Low battery voltage

LWFUEL

Low fuel

LWHUM

Low humidity

LWPRES

Low cable pressure

LWTEMP

Low temperature

LWWTR

Low water

MISC

Miscellaneous

OPENDR

Open door

POWER

Commercial power failure

PUMP

Pump failure

PWR-48

48V power supply failure

PWR-139

-139V power converter

PWR-190

-190V power converter

PWRMJ

Power supply major

PWRMN

Power supply minor

RECT

Rectifier failure

RECTHI

Rectifier high voltage

RECTLO

Rectifier low voltage

RINGGENMJ

Ringing generator major

RINGGENMN

Ringing generator minor

RTACADSL

AC or AC/rectifier power fail ADSL equipment

RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

RTACPWR

AC or AC/rectifier power fail DCL equipment

RTACPWRENG

Commercial AC fail, site equipped with standby engine

RTBAYPWR

AC power loss distributed power RT bay

RTRVENG

Retrieve standby engine, commercial AC restored

SMOKE

Smoke

TEMP

High-low temperature

TOXICGAS

Toxic gas

TREPEATER

T-repeater shelf

VENTN

Ventilation system failure


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>:<NTFCNCDE>,<ALMTYPE>,[<OCRDAT>],[<OCRTM>],[<DESC>]"

;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"ENV-IN-1:MJ,OPENDR,08-01,14-25-59,\"OPEN DOOR\""
;

Output Parameters

Table 21-22 RTRV-ALM-ENV Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.9  ENV" section on page 25-14

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

ALMTYPE

The alarm type for the environmental alarm. A null value is equivalent to ALL

Parameter type is ENV_ALM—environmental alarm types

AIRCOMPR

Air compressor failure

AIRCOND

Air conditioning failure

AIRDRYR

Air dryer failure

BATDSCHRG

Battery discharging

BATTERY

Battery failure

CLFAN

Cooling fan failure

CPMAJOR

Centralized power major failure

CPMINOR

Centralized power minor failure

ENGINE

Engine failure

ENGOPRG

Engine operating

ENGTRANS

Standby engine transfer

EXPLGS

Explosive gas

FIRDETR

Fire detector failure

FIRE

Fire

FLOOD

Flood

FUELLEAK

Fuel leak

FUSE

Fuse failure

GASALARM

Explosive gas, toxic gas, ventilation fail or gas monitor fail

HATCH

CEV hatch fail

GEN

Generator failure

HIAIR

High air flow

HIHUM

High humidity

HITEMP

High temperature

HIWTR

High water

INTRUDER

Intrusion

LEVELCON

Level converter

LVDADSL

Secondary ADSL low voltage disconnect

LVDBYPAS

Low voltage disconnect bypass

LWBATVG

Low battery voltage

LWFUEL

Low fuel

LWHUM

Low humidity

LWPRES

Low cable pressure

LWTEMP

Low temperature

LWWTR

Low water

MISC

Miscellaneous

OPENDR

Open door

POWER

Commercial power failure

PUMP

Pump failure

PWR-48

48V power supply failure

PWR-139

-139V power converter

PWR-190

-190V power converter

PWRMJ

Power supply major

PWRMN

Power supply minor

RECT

Rectifier failure

RECTHI

Rectifier high voltage

RECTLO

Rectifier low voltage

RINGGENMJ

Ringing generator major

RINGGENMN

Ringing generator minor

RTACADSL

AC or AC/rectifier power fail ADSL equipment

RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

RTACPWR

AC or AC/rectifier power fail DCL equipment

RTACPWRENG

Commercial AC fail, site equipped with standby engine

RTBAYPWR

AC power loss distributed power RT bay

RTRVENG

Retrieve standby engine, commercial AC restored

SMOKE

Smoke

TEMP

High-low temperature

TOXICGAS

Toxic gas

TREPEATER

T-repeater shelf

VENTN

Ventilation system failure

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

A condition description. String. Optional


21.12  RTRV-ALM-EQPT

Retrieve Alarm Equipment

Usage Guidelines

This command retrieves and sends the current status of alarm conditions associated with the equipment units. The alarm condition or severity to be retrieved is specified using the input parameters as a filter.

Category

Equipment

Security

Retrieve

Related Commands

ALW-SWDX-EQPT

ALW-SWTOPROTN-EQPT

ALW-SWTOWKG-EQPT

CLR-COND-SECU

DLT-EQPT

ED-EQPT

ENT-EQPT

INH-SWDX-EQPT

INH-SWTOPROTN-EQPT

INH-SWTOWKG-EQPT

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-SYNCN

RTRV-ALMTH-EQPT

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-EQPT

SET-ALMTH-EQPT

SW-DX-EQPT

SW-TOPROTN-EQPT

SW-TOWKG-EQPT


Input Format

RTRV-ALM-EQPT:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],[<SRVEFF>][,,,];

Input Example

RTRV-ALM-EQPT:TWOROCK:SLOT-7:227::MJ,HITEMP,NSA;

Input Parameters

Table 21-23 RTRV-ALM-EQPT Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.10  EQPT" section on page 25-15. Must not be null

NTFCNCDE

Two-letter notification code. A null value is equivalent to ALL

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

The condition type for an alarm or a reported event. A null value is equivalent to ALL

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service. A null value is equivalent to ALL

NSA

The condition is non-service affecting

SA

The condition is service affecting


Output Format

SID DATE TIME
M CTAG COMPLD
"[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,
[<OCRDAT>],[<OCRTM>],,,:[<DESC>]"

;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"SLOT-7,EQPT:MJ,HITEMP,NSA,08-01,14-25-59,,:\"HI TEMPERATURE\","
;

Output Parameters

Table 21-24 RTRV-ALM-EQPT Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.10  EQPT" section on page 25-15. Optional

AIDTYPE

Type of facility, link or other addressable entity targeted by the message. Optional

Parameter type is MOD2B—alarm type

1GFC

1 Gigabit Fibre Channel alarm

1GFICON

1 Gigabit FICON alarm

2GFC

2 Gigabit Fibre Channel alarm

2GFICON

2 Gigabit FICON alarm

BITS

BITS alarm

CLNT

Client facility for MXP/TXP cards

COM

Common alarm

DS3I

DS3I alarm

E1

E1 alarmed

E100

E100 alarm

E1000

E1000 alarm

E3

E3 alarm

E4

E4 alarm

ENV

ENV alarm

EQPT

EQPT alarm

FSTE

Fast Ethernet Port alarm

G1000

G1000 alarm

GIGE

GIG Ethernet port alarm

STM1

STM1 alarm

STM4

STM4 alarm

STM16

STM16 alarm

STM64

STM64 alarm

OCH

Optical channel

OMS

Optical Multiplex Section

OTS

Optical Transport Section

POS

POS port alarm

STM1E

STM1E alarm

VC11

VC11 alarm

VC12

VC12 alarm

VC3

VC3 alarm

VC44C

VC44C alarm

VC38C

VC38C alarm

VC464C

VC464C alarm

VC48C

VC48C alarm

VC4

VC4 alarm

VC416C

VC416C alarm

VC42C

VC42C alarm

VC43C

VC43C alarm

SYNCN

SYNCN alarm

TCC

TCC alarm

NTFCNCDE

Two-letter notification code

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

Condition type for an alarm or a reported event

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service

NSA

The condition is non-service affecting

SA

The condition is service affecting

OCRDAT

Date. Optional

OCRTM

Time. Optional

DESC

A condition description. String. Optional


21.13  RTRV-ALM-SYNCN

Retrieve Alarm Synchronization

Usage Guidelines

This command retrieves and sends the current status of alarm conditions associated with a synchronization facility. The alarm condition or severity to be retrieved can be specified by using the input parameters as a filter.

Category

Synchronization

Security

Retrieve

Related Commands

CLR-COND-SECU

ED-BITS

ED-NE-SYNCN

ED-SYNCN

OPR-SYNCNSW

REPT ALM <MOD2ALM>

REPT ALM BITS

REPT ALM COM

REPT ALM ENV

REPT ALM EQPT

REPT ALM SECU

REPT ALM SYNCN

REPT EVT <MOD2ALM>

REPT EVT BITS

REPT EVT COM

REPT EVT ENV

REPT EVT EQPT

REPT EVT FXFR

REPT EVT IOSCFG

REPT EVT SECU

REPT EVT SESSION

REPT EVT SYNCN

RLS-SYNCNSW

RTRV-ALM-<MOD2ALM>

RTRV-ALM-ALL

RTRV-ALM-BITS

RTRV-ALM-ENV

RTRV-ALM-EQPT

RTRV-BITS

RTRV-COND-<MOD2ALM>

RTRV-COND-ALL

RTRV-COND-BITS

RTRV-COND-ENV

RTRV-COND-EQPT

RTRV-COND-SYNCN

RTRV-NE-SYNCN

RTRV-SYNCN


Input Format

RTRV-ALM-SYNCN:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];

Input Example

RTRV-ALM-SYNCN:FULTON:SYNC-NE:226::CR,FAILTOSW,SA;

Input Parameters

Table 21-25 RTRV-ALM-SYNCN Input Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.22  SYNC_REF" section on page 25-20. Must not be null

NTFCNCDE

Two-letter notification code. A null value is equivalent to ALL

Parameter type is NOTIF_CODE—two-character notification code associated with an autonomous message

CL

The condition causing the alarm has cleared

CR

A critical alarm

MJ

A major alarm

MN

A minor alarm

NA

The condition is not alarmed

NR

The alarm is not reported

CONDTYPE

The condition type for an alarm or a reported event. A null value is equivalent to ALL

Parameter type is CONDITION—any problem detected on an ONS 15454 SDH shelf, whether or not the problem is reported (that is, whether or not it generates a trouble notification). Reported conditions include alarms, Not-Alarmed conditions (NA), and Not-Reported (NR) conditions. See Table 26-1 on page 26-1 for a list of conditions

SRVEFF

The effect on service caused by the standing alarm or condition

Parameter type is SERV_EFF—the effect of the alarm on service. A null value is equivalent to ALL

NSA

The condition is non-service affecting

SA

The condition is service affecting


Output Format

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,
[<OCRDAT>],[<OCRTM>],,:[<DESC>]"

;

Output Example

TID-000 1998-06-20 14:30:00
M 001 COMPLD
"SYNC-NE,SYNCN:CR,FAILTOSW,SA,
08-01,14-25-59,,:\"FAILURE TO SWITCH TO PROTECTION\","
;

Output Parameters

Table 21-26 RTRV-ALM-SYNCN Output Parameters 

Parameter and Values
Description

AID

Access identifier from the "25.1.20  SYN" section on page 25-20

AIDTYPE

Type of facility, link or other addressable entity targeted by the message. Optional

Parameter type is MOD2B—alarm type

1GFC

1 Gigabit Fibre Channel alarm

1GFICON

1 Gigabit FICON alarm

2GFC

2 Gigabit Fibre Channel alarm

2GFICON

2 Gigabit FICON alarm