This chapter describes the access identifiers (AIDs) of TL1 commands and autonomous messages for the Cisco ONS 15454 SDH, Release 6.0.
The AID code directs an input command to its intended physical or data entity inside the network element (NE). Equipment modules and facilities are typical examples of entities addressed by the access code.
The BAND AID is used to access the Optical Multiplex Section (OMS) layer of Optical Networking units.
Table 25-4 BAND
Pattern
Description
ALL
All of the OMSs of the NE. The ALL AID is applicable for retrieve-only commands
BAND-{1-6,12-17}-{1-4}-ALL
All the channels in a Band OADM (1Bn, 4Bn) unit
BAND-{1-6,12-17}-{1-4}-{RX,TX}
The Receive/Transmit Channels in a Band OADM (1Bn, 4Bn) unit
BAND-{1-6,12-17}-{1}-ALL
All the channels in an Optical Multiplexer/Demultiplexer (4Ch) unit
BAND-{1-6,12-17}-{1}-{RX,TX}
The Receive/Transmit Channels in an Optical Multiplexer/Demultiplexer (4Ch) unit
25.1.4 BITS
AID for building integrated timing supply (BITS).
Table 25-5 BITS
Pattern
Description
ALL
The ALL AID is applicable to RTRV commands only (RTRV-BITS and RTRV-ALM/COND-BITS). The All AID is equivalent to BITS-ALL for these commands. For RTRV-ALM/COND-SYNCN, the ALL AID translates to BITS-ALL, SYNC-BITS1, and SYNC-BITS2
BITS-ALL
BITS AIDs of both BITS-1 and BITS-2 in the RTRV-BITS command.
BITS-{1,2}
Individual BITS AID.
SYNC-BITS{1,2}
BITS-OUT AIDs of BITS-1 and BITS-2. These AIDs are applicable only in ED/RTRV-BITS commands and are used for setting and retrieving the BITS-OUT parameters.
25.1.5 CHANNEL
Accesses the Optical Channels (OCH) layer of Optical Networking/Client units.
Table 25-6 CHANNEL
CHANNEL Values
Description
ALL
ALL OCHs of the NE. The ALL AID is applicable for retrieve-only commands
CHAN-{1-6,12-17}-ALL
All the channels of an Optical Transponder/Muxponder. The format is CHAN-[SLOT]-ALL
CHAN-{1-6,12-17}-{1-32}-ALL
All the channels in an Optical Multiplexer/Demultiplexer (32Ch) unit. The format is CHAN-[SLOT]-[PORT]-ALL
CHAN-{1-6,12-17}-{1-32}-{RX,TX}
The Receive/Transmit channels in an Optical Multiplexer/Demultiplexer (32Ch) units. The format is CHAN-[SLOT]-[PORT]-[DIRECTION]
CHAN-{1-6,12-17}-{1-4}-ALL
All the channels in an OADM (1Ch, 2Ch, 4Ch) unit and Optical and Optical Multiplexer/Demultiplexer (4Ch) unit. The format is CHAN-[SLOT]-[PORT]-ALL
CHAN-{1-6,12-17}-{1-4}-{RX,TX}
The Receive/Transmit Channels in an OADM (1Ch, 2Ch, 4Ch) unit and Optical Multiplexer/Demultiplexer (4Ch) unit. The format is CHAN-[SLOT]-[PORT]-[DIRECTION]
CHAN-{1-6,12-17}-{2,3}
A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G and TXP_MR_2.5G use CHAN-slot-2 for the 1 DWDM Facility. TXPP_MR_2.5G uses CHAN-[SLOT]-{2,3} for the two DWDM facilities. The format is CHAN-[SLOT]-[PORT]
CHAN-{1-6,12-17}-{2,5}
A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G uses CHAN-[SLOT]-2 for the 1 DWDM facility. MXP_2.5G_10G uses the CHAN-slot-5 for the 1 DWDM facility. The format is CHAN-[SLOT]-[PORT]
The ALL AID applies to retrieve-only commands: RTRV-ALM/COND-ENV, RTRV-ATTR-CONT, and RTRV-ATTR-ENV
ENV-IN-ALL
Environmental AID for ALL environmental alarms
ENV-IN-{1-4}
Environmental AID for the AIC-I Card. "IN" is used for environmental alarms
ENV-IN-{1-20}
Environmental AID for the AIC-I Card. "IN" is used for environmental alarms
ENV-IN-{1-32}
Environmental AID for AIC-I Card Extensions. "IN" is used for environmental alarms
ENV-IN-{1-16}
Environmental AID. "IN" is used for environmental alarms
ENV-OUT-ALL
Environmental AID for AIC-I Cards. "OUT" is used for environmental controls
ENV-OUT-{1-4}
Environmental AID for AIC-I Cards. "OUT" is used for environmental controls
ENV-OUT-{1-16}
Environmental AID for AIC-I Card Extensions. "OUT" is used for environmental controls
ENV-{IN,OUT}-{1-16}
ENV-IN[1-16} is used for the environmental alarm AID. ENV-OUT-{1-16} is used for the external control AID
25.1.10 EQPT
Equipment AIDs are used to access specific cards.
Table 25-11 EQPT
Pattern
Description
AIP
The AID for the AIP. It is used for RTRV-INV output only
ALL
Only used for RTRV-INV, RTRV-EQPT, and RTRV-ALM/COND-EQPT commands. RTRV-INV returns all the inventory information for the NE. Includes the I/O cards, controller cards, and the AIP, BP, and FAN
BIC-ALL
AIDs for the Backplane Interface Connectors (BICs): BIC-A and BIC-B. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands
BIC-{A,B}
AIDs for the BICs. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands
BP
The AID for the backplane. It is used for RTRV-INV output only
FAN
The AID for the fan tray. It is used for RTRV-INV output only
PPM-{1-6,12-17}-1
Pluggable Port Module for STM64-XFP. Format is PPM-[SLOT]-[PPM]
PPM-{1-6,12-17}-{1-12}
Pluggable Port Module for MRC-12. Format is PPM-[SLOT]-[PPM]
PPM-{1-6,12-17}-{1-4}
PPM AID for DWDM MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_10E cards. Format of AID is PPM-[SLOT]-[PPM]
PPM-{1-6,12-17}-{1-8}
PPM AID for the ONS 15454 SDH MXP_MR_2.5G and MXPP_MR_2.5G card. Format of AID is PPM-[SLOT]-[PPM]
PWR-ALL
AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
PWR-{A,B}
AIDs for the power supply sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
SLOT-ALL
All of the NE equipment AIDs
SLOT-{1-17}
EQPT AID where format is SLOT-[SLOT]
SLOT-{1-6,12-17}
Individual equipment AID of the I/O card units or slots where format is SLOT-[SLOT]
25.1.11 FACILITY
Facilities AIDs are used to access specific ports.
Facility AID format:
•Format for DS3i-N-12 electrical facilities: FAC-[SLOT]-[PORT]
•Format for POS ports: VFAC-[SLOT]-[PORT]
•Format for POS port with PIM and PPM: VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
Table 25-12 FACILITY
Pattern
Description
ALL
The ALL AID is applicable for RTRV-only commands (RTRV-rr type of commands), for example: RTRV-STM16 with an ALL AID returns all STM16 facilities on the node
FAC-{1-4,14-17}-{1-8}
Facilities for an STM1 card where the format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-1
Facility AID for the 1 Client (CLNT) port on a TXP_MR_10G, TXP_MR_2.5G, TXP_MR_2.5G or TXPP_MR_2.5G card where the format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-ALL
All the facilities of an I/O unit or slot where the format is FAC-[SLOT]-[ALL]
FAC-{1-6,12-17}-{0-11}
Facilities for the Ethernet front-end ports on the ML100T-12 card. Ports are numbered starting with 0 (that is, the first port is FAC-SLOT-0, second port is FAC-SLOT-1, ..., last port is FAC-SLOT-11 for ML100T-12, first port is FAC-SLOT-0 and second port is FAC-SLOT-1 for ML1000-2). The format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-{0-1}
Facilities for the Ethernet back-end Ports on the ML1000-2 card. Ports are 0-based, (for example, the first port is FAC-SLOT-0 and the second port is FAC-SLOT-1). The format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-{1-8}
Facility AID for the Ethernet front-end ports on the CE-100T-8 card The format is FAC-[SLOT]-[PORT].
Facility AIDs for the DS3i-N-12 VC416 Backplane Rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available
FAC-{1-6,12-17}-{1-12,14,16,18, 20,22,24}
Facility AIDs for DS3i-N-12 VC44 Backplane Rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available
FAC-{1-6,12-17}-{1-4}
Facility AID for the four Client (CLNT) facilities on the MXP_2.5G_10G card. Facility AID for 4-Port G1000/FC_MR-4 card. Facility AID for creating/editing cross-connects (VC3, VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C) for the 4-Port G1000/FC_MR-4 card where format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-{1-6}
Facilities for the DS3i-N-12 card where the format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-{1}
Facility AID for the 1-Port STM4, STM16, and STM1 in OSC-CSM cards. Facility AID for the client ports on the MXP/TXP and TXP_MR_2.5G cards where format is FAC-[SLOT]-[PORT]
FAC-{5,6,12,13}-{1}
Facility AID for the STM16/STM64 cards. The STM16/STM64 cards can only use Slot 5, Slot 6, Slot 12, and Slot 13 where format is FAC-[SLOT]-[PORT]
FAC-{8,10}-{1}
Facility AID for the OSCM card. The OSCM cards can only use the XC10G slots (Slot 8, Slot 10) where format is FAC-[SLOT]-[PORT]
VFAC-{1-6,12-17}-{0-1}
Facilities for the back-end POS ports on the ML-Series card. Port numbering is 0-based (first POS port is VFAC-SLOT-0, second POS port is VFAC-SLOT-1). VC4, VC4-2C, VC4-3C, VC4-4C, and VC4-8C for the ML1000 and ML100T cards. Format is VFAC-[SLOT]-[PORT]
VFAC-{1-6,12-17}-{1,2}
GFP facilities on the MXP-MR-2.5G and MXPP-MR-2.5G cards
VFAC-{1-6,12-17}-{1,2}-{1,8}
GFP Client facilities for MXP-MR-2.5G and MXPP-MR-2.5G cards
25.1.12 IPADDR
IP Address
Table 25-13 IPADDR
Pattern
Description
111.222.333.444
Standard 4 Part IP Address Notation
ALL
ALL
25.1.13 LINE
The LINE AID is used to access the Optical Transport Section (OTS) layer of optical networking units. Applicable only to ONS 15454 SDH AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O, and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION].
Table 25-14 LINE
Values
Description
ALL
All of the OTSs of the NE. The ALL AID applies to retrieve-only commands
LINE-{1-6,12-17}-{1-2}-ALL
All the lines in a OPT-PRE, OCS-CSM, AD-1B, AD-4B, AD-1C, AD-2C, and AD-4C units
LINE-{1-6,12-17}-{1-2}-{RX,TX}
The receive/transmit Lines in a OPT-PRE, OCS-CSM, AD-1B, AD-4B, AD-1C, AD-2C, and AD-4C units
LINE-{1-6,12-17}-{1-3}-ALL
All the lines in a OPT-BST units
LINE-{1-6,12-17}-{1-3}-{RX,TX}
The receive/transmit lines in a OPT-BST units
LINE-{8,10}-{1}-ALL
All the lines in a OSCM units
LINE-{8,10}-{1}-{RX,TX}
The receive/transmit lines in OSCM units
25.1.14 LNKTERM
Link Termination AIDs that are used to access the termination points of a provisionable patchcord.
Table 25-15 LNKTERM
Pattern
Description
ALL
Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands
LNKTERM-ALL
Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands
LNKTERM-{1-65535}
Indicates a single provisionable patchcord termination point on a node
25.1.15 MSSPR
MS-SPRing AIDs are used to access the MS-SPRing of the NE.
Table 25-16 MSSPR
Pattern
Description
ALL
ALL AID for all MS-SPRings in the NE. The ALL AID is applicable for retrieve-only commands like RTRV-MSSPR and RTRV-ALM/COND-MSSPR
MSSPR-RINGID
MS-SPRing AID is keyword MS-SPRing followed by RINGID. RINGID is a string of up to 6 characters; valid characters are [A-Z,0-9] (case insensitive)
25.1.16 OPM
OPM AIDs represent the single wavelength inside an optical power monitoring object
The second index is the slot where the 32 WSS unit is configured. The last index of the wavelength is the value of the wavelength as described in OPTICAL_WLEN
25.1.17 OSC
OSC AIDs are used to access the OSC of the NE
Table 25-18 OSC
Values
Description
ALL
All of the OSCs of the NE. The ALL AID applies to the retrieve-only commands
OSC-RINGID
RINGID is a string of up to six characters, valid characters are [A-Z,0-9] (case insensitive)
25.1.18 PRSLOT
Valid protection slots for the electrical cards. Format is SLOT-[SLOT].
Table 25-19 PRSLOT
Pattern
Description
NULL
Indicates there is no protection group. Used when trying to delete a protection group.
SLOT-1
The No. 1 slot of an NE
SLOT-3
The No. 3 slot of an NE
SLOT-5
The No. 5 slot of an NE
SLOT-13
The No. 13 slot of an NE
SLOT-15
The No. 15 slot of an NE
SLOT-17
The No. 17 slot of an NE
25.1.19 RFILE
File transfer type.
Table 25-20 RFILE
Pattern
Description
RFILE-DB
Transferring the system database
RFILE-PKG
Transferring a software package
25.1.20 SYN
Synchronization AIDs
Table 25-21 SYN
Pattern
Description
SYNC-NE
NE synchronization AID
25.1.21 SYN_SRC
Synchronization source
Table 25-22 SYN_SRC
Pattern
Description
BITS-1
Synchronization source is BITS-1. Format is BITS-[PORT]
BITS-2
Synchronization source is BITS-2. Format is BITS-[PORT]
FAC-{1-4,11-14}-{1-4}
Synchronization source is 4-Port STM64. Format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-{1-4}
Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT]
FAC-{1-6,12-17}-{1}
Synchronization source is the optical card (STM1 and STM4) facility. Format is FAC-[SLOT]-[PORT]
FAC-{5,6,12,13}-{1}
Synchronization source is the optical card (STM16 and STM 64) facility. Format is FAC-[SLOT]-[PORT]
INTERNAL
Set the SYN_SRC to be the system default value. The "Internal" value of the SYN_SRC is only applied for the SYNC-NE AID on the ED-SYNCN command
NONE
Set the SYNC_SRC value to the default value for BITS-OUT. The "NONE" value of SYNC_SRC only applies to the BITS-1 and BITS-2 AID of the ED-SYNCN command
SYNC-NE
SYNC-NE source. It is only used in the alarm report or alarm retrieve commands.
25.1.22 SYNC_REF
Synchronization AIDs
Facility AID format for line timing:
•Format for optical facilities without PPM: FAC-[SLOT]-[PORT]
•Format for optical facilities with PPM: FAC-[SLOT]-[PPM]-[PORT]
Table 25-23 SYNC_REF
Pattern
Description
ALL
Equivalent to a combination of SYNC-ALL, BITS-1, and BITS-2. This AID is valid only for the commands RTRV-SYNCN, RTRV-ALM-SYNCN, and RTRV-COND-SYNCN
SYNC-ALL
All synchronization references
SYNC-NE
NE synchronization AID
SYNC-{BITS1,BITS2}
BITS1 and BITS2 sync AIDs
25.1.23 SYNCSW
Synchronization reference
Table 25-24 SYNCSW
Pattern
Description
INT
Internal clock. The "INT" value of the SYNCSW is only applied for the SYNC-NE AID on the OPR-SYNCSW command.
PRI
Primary timing reference
SEC
Secondary timing reference
THIRD
Third timing reference
25.1.24 UDC
UDC AIDs for F-UDC and DCC-UDC channels on the AIC-I card.
Table 25-25 UDC
Pattern
Description
ALL
ALL AID is applicable to retrieve-only commands, for example: RTRV-ALM/COND-UDCF and RTRV-ALM/COND-UDCDCC. It corresponds to a superset of F-UDC and DCC-UDC AIDs
VC4 for the STM4 card and VC4-4c for the STM4-4 card
VC4-{1-4,14-17}-{1-4}-{1-2}
VC4-3c for the STM4-4 card
VC4-{1-4,14-17}-{1-4}-{1-3}
VC4-2c for the STM4-4 card
VC4-{1-4,14-17}-{1-4}-{1-4}
VC4 for the STM4-4 card
VC4-{1-4,14-17}-{1-8}-1
VC4 for the STM1-8 card
VC4-{1-6,12-17}-1
VC4 for E1 card
VC4-{1-6,12-17}-1-1
VC4-4c for the STM-4 card. VC4-16c for the STM-16 card
VC4-{1-6,12-17}-1-{1,2,3,5,6,7,9,10,11,13,14,15}
VC4-2c for the STM-16 card
VC4-{1-6,12-17}-1-{1,2,4,5,6,7,9,10,13,14}
VC4-3c for the STM-16
VC4-{1-6,12-17}-1-{1,5,9,13}
VC4-4c for the STM-16 card
VC4-{1-6,12-17}-1-{1-16}
VC4 for the STM-16 card
VC4-{1-6,12-17}-1-{1-2}
VC4-3c for the STM-4 card
VC4-{1-6,12-17}-1-{1-3}
VC4-2c for the STM-4 card
VC4-{1-6,12-17}-1-{1-4}
VC4 for the STM-4 card
VC4-{1-6,12-17}-1-{1-9}
VC4-8c for the STM-16 card (454)
VC4-{1-6,12-17}-{1-4}
VC4 for DS3i-N-12, E3, G1000 cards
VC4-{1-6,12-17}-{1-4}-1
VC4 for STM-1 card
25.1.26 WDMANS
This AID is used to access the automatic optical node set up (AONS) application of the NE.
Table 25-27 WDMANS
Pattern
Description
AONS-{E,W}
Automatic Optical Node Setup identifier (per ring direction based)
WDMANS-{E,W}
Automatic Optical Node Setup identifier (per ring direction based)
25.1.27 WLEN
This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line) the wavelengths contained are all the available in the node: currently 32. If the facility is of type OCH (CHAN) the wavelength is just one and it is the same of the correspondent wavelength customized for that channel.