Table Of Contents
Power Down the Node
NTP-D114 Power Down the Node
Power Down the Node
This chapter explains how to power down a node and stop all node activity on the Cisco ONS 15454 SDH.
NTP-D114 Power Down the Node
Purpose
|
This procedure stops all node activity.
|
Tools/Equipment
|
None
|
Prerequisite Procedures
|
None
|
Required/As Needed
|
As needed
|
Onsite/Remote
|
Onsite
|
Security Level
|
For software steps, the Provisioning level or higher is required. For hardware steps, any level is allowed.
|
Warning
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed circuitry could constitute an energy hazard. Statement 206
Caution 
The following procedure is designed to minimize traffic outages when powering down nodes, but traffic will be lost if you delete and recreate circuits that passed through a working node.
Note
Always use the supplied ESD wristband when working with the Cisco ONS 15454 SDH. Plug the wristband into the ESD jack located on the fan-tray assembly or on the lower right outside edge of the shelf assembly. To access the ESD plug on the shelf assembly, open the front door of the Cisco ONS 15454 SDH. The front door is grounded to prevent electrical shock.
Step 1
Identify the node that you want to power down. If no cards are installed, go to Step 13. If cards are installed, log into the node. See the "DLP-D60 Log into CTC" task on page 17-48 for instructions.
Step 2
In node (login) view, choose Go to Network View from the View menu.
Step 3
In network view, verify that the node is not connected to a network.
a.
If the node is part of a working network, log out of the node and complete the "NTP-D322 Remove an In-Service Node from a Linear ADM" procedure on page 14-17, the "NTP-D213 Remove an MS-SPRing Node" procedure on page 14-6, or the "NTP-D106 Remove an SNCP Node" procedure on page 14-12. If the node is part of a Software R6.0 MSTP configuration, consult your network administrator. (Linear configurations will be deleted in Step 5.) Continue with the next step.
b.
If the node is not connected to a working network and the current configurations are no longer required, continue with the next step.
Note
Current configurations will be saved if Steps 4 through 13 are skipped.
Step 4
In node view, click the Circuits tab and verify that no circuits are displayed, then proceed to Step 5. If circuits appear, delete all the circuits that originate or terminate in the node, as follows:
a.
Click the circuits that need to be deleted and click Delete.
b.
Click Yes.
Repeat until no circuits appear.
Step 5
In node view, click the Provisioning > Protection tabs and delete all protection groups:
a.
Click the protection group that needs to be deleted and click Delete.
b.
Click Yes.
Repeat until no protection groups appear.
Step 6
In node view, click the Provisioning > Comm Channels tabs and delete all RS-DCC, MS-DCC, GCC, or OSC terminations:
a.
Click the regenerator section data communications channel (RS-DCC), multiplex section data communications channel (MS-DCC), generic communications channel (GCC), or OSC termination that needs to be deleted and click Delete.
b.
Click Yes.
Repeat until no RS-DCC, MS-DCC, GCC, or OSC terminations are present.
Note
Before deleting the OSC termination, make sure the Ring ID is deleted. Click the Provisioning > Comm Channels > OSC tabs. Select the Ring ID and click Delete.
Step 7
For each installed STM-N or DS-N card, make sure all ports are in Locked-enabled,disabled service state:
a.
In card view, click the Provisioning > Line tabs.
b.
Click under the Status column for each port and choose Locked,disabled is selected
Step 8
Remove all fiber connections to the cards.
Step 9
In node view, right-click an installed card and click Delete.
Step 10
Click Yes.
Step 11
After you have deleted the card, open the card ejectors and remove it from the node.
Step 12
Repeat Steps 7 through 11 for each installed card.
Note
You cannot delete a TCC2 card in CTC. Physically remove it after all the other cards have been deleted and removed.
Step 13
Shut off the power from the power supply that feeds the node.
Step 14
Disconnect the node from its external fuse source.
Step 15
Store all the cards you removed and update inventory records according to local site practice.
Stop. You have completed this procedure.