- Preface
- New and Changed Information
- Overview
- Equipment Policies
- Chassis Management
- I/O Module Management
- SIOC Management
- Power Management in Cisco UCS
- Blade Server Hardware Management
- Rack-Mount Server Hardware Management
- S3260 Server Node Hardware Management
- Virtual Interface Management
- Troubleshoot Infrastructure
- Blade Server Management
- Booting a Blade Server
- Booting a Rack-Mount Server from the Service Profile
- Determining the Boot Order of a Blade Server
- Shutting Down a Blade Server
- Shutting Down a Server from the Service Profile
- Resetting a Blade Server
- Resetting a Blade Server to Factory Default Settings
- Reacknowledging a Blade Server
- Removing a Server from a Chassis
- Deleting the Inband Configuration from a Blade Server
- Decommissioning a Blade Server
- Recommissioning a Blade Server
- Reacknowledging a Server Slot in a Chassis
- Removing a Non-Existent Blade Server from the Configuration Database
- Turning the Locator LED for a Blade Server On and Off
- Turning the Local Disk Locator LED on a Blade Server On and Off
- Resetting the CMOS for a Blade Server
- Resetting the CIMC for a Blade Server
- Clearing TPM for a Blade Server
- Viewing the POST Results for a Blade Server
- Issuing an NMI from a Blade Server
- Viewing Health Events for a Blade Server
- Health LED Alarms
- Smart SSD
Blade Server
Hardware Management
- Blade Server Management
- Booting a Blade Server
- Booting a Rack-Mount Server from the Service Profile
- Determining the Boot Order of a Blade Server
- Shutting Down a Blade Server
- Shutting Down a Server from the Service Profile
- Resetting a Blade Server
- Resetting a Blade Server to Factory Default Settings
- Reacknowledging a Blade Server
- Removing a Server from a Chassis
- Deleting the Inband Configuration from a Blade Server
- Decommissioning a Blade Server
- Recommissioning a Blade Server
- Reacknowledging a Server Slot in a Chassis
- Removing a Non-Existent Blade Server from the Configuration Database
- Turning the Locator LED for a Blade Server On and Off
- Turning the Local Disk Locator LED on a Blade Server On and Off
- Resetting the CMOS for a Blade Server
- Resetting the CIMC for a Blade Server
- Clearing TPM for a Blade Server
- Viewing the POST Results for a Blade Server
- Issuing an NMI from a Blade Server
- Viewing Health Events for a Blade Server
- Health LED Alarms
- Smart SSD
Blade Server Management
You can manage and monitor all blade servers in a Cisco UCS domain through Cisco UCS Manager. You can perform some blade server management tasks, such as changes to the power state, from the server and service profile.
The remaining management tasks can only be performed on the server.
The power supply units go into power save mode when a chassis has two blades or less. When a third blade is added to the chassis and is fully discovered, the power supply units return to regular mode.
If a blade server slot in a chassis is empty, Cisco UCS Manager provides information, errors, and faults for that slot. You can also re-acknowledge the slot to resolve server mismatch errors and to have Cisco UCS Manager rediscover the blade server in the slot.
- Guidelines for Removing and Decommissioning Blade Servers
- Recommendations for Avoiding Unexpected Server Power Changes
Guidelines for Removing and Decommissioning Blade Servers
Consider the following guidelines when deciding whether to remove or decommission a blade server using Cisco UCS Manager:
Decommissioning a Blade Server
If you want to temporarily decommission a physically present and connected blade server, you can temporarily remove it from the configuration. A portion of the server's information is retained by Cisco UCS Manager for future use, in case the blade server is recommissioned.
Removing a Blade Server
Removing is performed when you physically remove a blade server from the Cisco UCS Manager by disconnecting it from the chassis. You cannot remove a blade server from Cisco UCS Manager if it is physically present and connected to a chassis. After the physical removal of the blade server is completed, the configuration for that blade server can be removed in Cisco UCS Manager.
During removal, active links to the blade server are disabled, all entries from databases are removed, and the server is automatically removed from any server pools that it was assigned to during discovery.
![]() Note | Only servers added to a server pool automatically during discovery are removed automatically. Servers that were manually added to a server pool must be removed manually. |
To add a removed blade server back to the configuration, it must be reconnected, then rediscovered. When a server is reintroduced to Cisco UCS Manager, it is treated as a new server and is subject to the deep discovery process. For this reason, it is possible for Cisco UCS Manager to assign the server a new ID that might be different from the ID that it held before.
Recommendations for Avoiding Unexpected Server Power Changes
If a server is not associated with a service profile, you can use any available means to change the server power state, including the physical Power or Reset buttons on the server.
If a server is associated with, or assigned to, a service profile, you should only use the following methods to change the server power state:
-
In Cisco UCS Manager GUI, go to the General tab for the server or the service profile associated with the server and select Boot Server or Shutdown Server from the Actions area.
-
In Cisco UCS Manager CLI, scope to the server or the service profile associated with the server and use the power up or power down commands.
Do not use any of the following options on an associated server that is currently powered off:
If you reset, cycle, or use the physical power buttons on a server that is currently powered off, the server's actual power state might become out of sync with the desired power state setting in the service profile. If the communication between the server and Cisco UCS Manager is disrupted or if the service profile configuration changes, Cisco UCS Manager might apply the desired power state from the service profile to the server, causing an unexpected power change.
Power synchronization issues can lead to an unexpected server restart, as shown below:
|
Desired Power State in Service Profile |
Current Server Power State |
Server Power State After Communication Is Disrupted |
||
|---|---|---|---|---|
|
Up |
Powered Off |
Powered On |
||
|
Down |
Powered On |
Powered On
|
Booting a Blade Server
If the Boot Server link is dimmed in the Actions area, you must shut down the server first.
After the server boots, the Overall Status field on the General tab displays an OK status.
Booting a Rack-Mount Server from the Service Profile
Determining the Boot Order of a Blade Server
![]() Tip | You can also view the boot order tabs from the General tab of the service profile associated with a server. |
Shutting Down a Blade Server
When you use this procedure to shut down a server with an installed operating system, Cisco UCS Manager triggers the OS into a graceful shutdown sequence.
If the Shutdown Server link is dimmed in the Actions area, the server is not running.
![]() Note | When a blade server that is associated with a service profile is shut down, the VIF down alerts F0283 and F0479 are automatically suppressed. |
After the server has been successfully shut down, the Overall Status field on the General tab displays a power-off status.
Shutting Down a Server from the Service Profile
When you use this procedure to shut down a server with an installed operating system, Cisco UCS Manager triggers the OS into a graceful shutdown sequence.
If the Shutdown Server link is dimmed in the Actions area, the server is not running.
| Step 1 | In the Navigation pane, click Servers. |
| Step 2 | Expand . |
| Step 3 | Expand the
node for the organization where you want to create the service profile.
If the system does not include multitenancy, expand the root node. |
| Step 4 | Choose the service profile that requires the associated server to shut down. |
| Step 5 | In the Work pane, click the General tab. |
| Step 6 | In the Actions area, click Shutdown Server. |
| Step 7 | If a confirmation dialog box displays, click Yes. |
After the server successfully shuts down, the Overall Status field on the General tab displays a down status or a power-off status.
Resetting a Blade Server
When you reset a server, Cisco UCS Manager sends a pulse on the reset line. You can choose to gracefully shut down the operating system. If the operating system does not support a graceful shutdown, the server is power cycled. The option to have Cisco UCS Manager complete all management operations before it resets the server does not guarantee the completion of these operations before the server is reset.
![]() Note | If you are trying to boot a server from a power-down state, you should not use Reset. If you continue the power-up with this process, the desired power state of the servers become out of sync with the actual power state and the servers might unexpectedly shut down at a later time. To safely reboot the selected servers from a power-down state, click Cancel, then select the Boot Server action. |
The reset may take several minutes to complete. After the server has been reset, the Overall Status field on the General tab displays an ok status.
Resetting a Blade Server to Factory Default Settings
You can now reset a blade server to its factory settings. By default, the factory reset operation does not affect storage drives and flexflash drives. This is to prevent any loss of data. However, you can choose to reset these devices to a known state as well.
Resetting storage devices will result in loss of data.
Perform the following procedure to reset the server to factory default settings.
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server that you want to reset to its factory default settings. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Server Maintenance. |
| Step 6 | In the Maintenance dialog box, do the following: |
| Step 7 | From the
Maintenance Server dialog box that appears, select
the appropriate options:
Cisco UCS Manager resets the server to its factory default settings. |
Reacknowledging a Blade Server
Perform the following procedure to rediscover the server and all endpoints in the server. For example, you can use this procedure if a server is stuck in an unexpected state, such as the discovery state.
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server that you want to acknowledge. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Server Maintenance. |
| Step 6 | In the
Maintenance dialog box, click
Re-acknowledge, then click
OK.
Cisco UCS Manager disconnects the server and then builds the connections between the server and the fabric interconnect or fabric interconnects in the system. The acknowledgment may take several minutes to complete. After the server has been acknowledged, the Overall Status field on the General tab displays an OK status. |
Removing a Server from a Chassis
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server that you want to remove from the chassis. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Server Maintenance. |
| Step 6 | In the
Maintenance dialog box, click
Decommission, then click
OK.
The server is removed from the Cisco UCS configuration. |
| Step 7 | Go to the
physical location of the chassis and remove the server hardware from the slot.
For instructions on how to remove the server hardware, see the Cisco UCS Hardware Installation Guide for your chassis. |
What to Do Next
If you physically re-install the blade server, you must re-acknowledge the slot for the Cisco UCS Manager to rediscover the server.
For more information, see Reacknowledging a Server Slot in a Chassis.
Deleting the Inband Configuration from a Blade Server
This procedure removes the inband management IP address configuration from a blade server. If this action is greyed out, no inband configuration was completed.
| Step 1 | In the Navigation pane, click Equipment. | ||
| Step 2 | Expand . | ||
| Step 3 | In the Work area, click the Inventory tab. | ||
| Step 4 | Click the CIMC subtab. | ||
| Step 5 | In the Actions area, click Delete Inband Configuration. | ||
| Step 6 | Click
Yes in the
Delete confirmation dialog box.
The inband configuration for the server is deleted.
|
Decommissioning a Blade Server
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server that you want to decommission. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Server Maintenance. |
| Step 6 | In the
Maintenance dialog box, do the following:
The server is removed from the Cisco UCS configuration. |
What to Do Next
If you physically re-install the blade server, you must re-acknowledge the slot for the Cisco UCS Manager to rediscover the server.
For more information, see Reacknowledging a Server Slot in a Chassis.
Recommissioning a Blade Server
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand Equipment node. |
| Step 3 | Click the Chassis node. |
| Step 4 | In the Work pane, click the Decommissioned tab. |
| Step 5 | On the row for each blade server that you want to recommission, check the check box in the Recommission column, then click Save Changes. |
| Step 6 | If a confirmation dialog box displays, click Yes. |
| Step 7 | (Optional)Monitor the progress of the server recommission and discovery on the FSM tab for the server. |
Reacknowledging a Server Slot in a Chassis
Perform the following procedure if you decommissioned a blade server without removing the physical hardware from the chassis, and you want Cisco UCS Manager to rediscover and recommission the server.
| Step 1 | In the Navigation pane, click Equipment. | ||||||
| Step 2 | Expand . | ||||||
| Step 3 | Choose the server whose slot you want to reacknowledge. | ||||||
| Step 4 | If
Cisco UCS Manager displays a
Resolve
Slot Issue dialog box, do one of the following:
|
Removing a Non-Existent Blade Server from the Configuration Database
Perform the following procedure if you physically removed the server hardware without first decommissioning the server. You cannot perform this procedure if the server is physically present.
If you want to physically remove a server, see Removing a Server from a Chassis.
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server that you want to remove from the configuration database. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Server Maintenance. |
| Step 6 | In the
Maintenance dialog box, click
Remove, then click
OK.
Cisco UCS Manager removes all data about the server from its configuration database. The server slot is now available for you to insert new server hardware. |
Turning the Locator LED for a Blade Server On and Off
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server for which you want to turn the locator LED on or off. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the
Actions area, click one of the following:
|
Turning the Local Disk Locator LED on a Blade Server On and Off
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server for which you want to turn the local disk locator LED on or off. |
| Step 4 | In the
Work pane, click the
tabs.
The Storage Controller inventory appears. |
| Step 5 | Click a disk. The disk details appear. |
| Step 6 | In the Details area, click Toggle Locator LED. If the Locator LED state is On, it will turn Off. If the Locator LED state is Off, it will turn On. |
| Step 7 | Click Save Changes. |
Resetting the CMOS for a Blade Server
Sometimes, troubleshooting a server might require you to reset the CMOS. Resetting the CMOS is not part of the normal maintenance of a server.
Resetting the CIMC for a Blade Server
Sometimes, with the firmware, troubleshooting a server might require you to reset the CIMC. Resetting the CIMC is not part of the normal maintenance of a server. After you reset the CIMC, the server boots with the running version of the firmware for that server.
If the CIMC is reset, the power monitoring functions of Cisco UCS become briefly unavailable until the CIMC reboots. Typically, the reset only takes 20 seconds; however, it is possible that the peak power cap can exceed during that time. To avoid exceeding the configured power cap in a low power-capped environment, consider staggering the rebooting or activation of CIMCs.
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server for which you want to reset the CIMC. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Recover Server. |
| Step 6 | In the Recover Server dialog box, click Reset CIMC (Server Controller), then click OK. |
Clearing TPM for a Blade Server
You can clear TPM only on Cisco UCS M4 blade and rack-mount servers that include support for TPM.
![]() Caution | Clearing TPM is a potentially hazardous operation. The OS may stop booting. You may also see loss of data. |
TPM must be enabled.
Viewing the POST Results for a Blade Server
You can view any errors collected during the Power On Self-Test process for a server and its adapters.
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server for which you want to view the POST results. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the
Actions area, click
View
POST Results.
The POST Results dialog box lists the POST results for the server and its adapters. |
| Step 6 | (Optional)Click the link in the Affected Object column to view the properties of that adapter. |
| Step 7 | Click OK to close the POST Results dialog box. |
Issuing an NMI from a Blade Server
Perform the following procedure if the system remains unresponsive and you need Cisco UCS Manager to issue a Non-Maskable Interrupt (NMI) to the BIOS or operating system from the CIMC. This action creates a core dump or stack trace, depending on the operating system installed on the server.
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Choose the server that you want to issue the NMI. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the Actions area, click Server Maintenance. |
| Step 6 | In the
Maintenance dialog box, do the following:
Cisco UCS Manager sends an NMI to the BIOS or operating system. |
Viewing Health Events for a Blade Server
| Step 1 | In the Navigation pane, click Equipment. | ||||||||||||||||||||||||
| Step 2 | Expand . | ||||||||||||||||||||||||
| Step 3 | Choose the server for which you want to view health events. | ||||||||||||||||||||||||
| Step 4 | In the
Work pane, click the
Health tab
The health events triggered for this server appear. The fields in this tab are:
| ||||||||||||||||||||||||
Health LED Alarms
The blade health LED is located on the front of each Cisco UCS B-Series blade server. Cisco UCS Manager allows you to view the sensor faults that cause the blade health LED to change color from green to amber or blinking amber.
The health LED alarms display the following information:
| Name | Description |
|---|---|
|
The severity of the alarm. This can be one of the following: |
|
|
Sensor ID column |
The ID of the sensor the triggered the alarm. |
|
Sensor Name column |
The name of the sensor that triggered the alarm. |
Viewing Health LED Alarms
| Step 1 | In the Navigation pane, click Equipment. |
| Step 2 | Expand . |
| Step 3 | Click the server for which you want to view health LED alarms. |
| Step 4 | In the Work pane, click the General tab. |
| Step 5 | In the
Actions area, click
View
Health LED Alarms.
The View Health LED Alarms dialog box lists the health LED alarms for the selected server. |
| Step 6 | Click OK to close the View Health LED Alarms dialog box. |
Smart SSD
Beginning with release 3.1(3), Cisco UCS Manager supports monitoring SSD health. This feature is called Smart SSD. It provides statistical information about the properties like wear status in days, percentage life remaining, and so on. For every property, a minimum, a maximum and an average value is recorded and displayed. The feature also allows you to provide threshold limit for the properties.
![]() Note | The Smart SSD feature is supported only for a selected range of SSDs. It is not supported for any HDDs. |
The SATA range of supported SSDs are:
-
Intel
-
Samsung
-
Micron
The SAS range of supported SSDs are:
-
Toshiba
-
Sandisk
-
Samsung
-
Micron
![]() Note |
|
Monitoring SSD Health
| Step 1 | Navigate to. | ||||
| Step 2 | Click the controller component for which you want to view the SSD health. | ||||
| Step 3 | In the Work pane, click the Statistics tab. | ||||
| Step 4 | Click the SSD for which you want to view the health properties.
You can view the values for
|



Feedback