Technical Specifications

System Specifications

Table 1. Physical Specifications

Description

Specification

Physical (Cisco UCS 6332)

Dimensions (H x W x D)

1.72 in. x 17.3 in. x 22.5 in. (4.4 cm x 43.94 cm x 57.1 cm)

Weight (with two power supplies installed)

22 lb (9.97 kg)

Physical (Cisco UCS 6332-16UP)

Dimensions (H x W x D)

1.72 in. x 17.3 in. x 22.5 in. (4.4 cm x 43.94 cm x 57.1 cm)

Weight (with two power supplies installed)

22.61 lb (10.25 kg)

Environmental

Temperature, operating

32 to 104°F (0 to 40°C)

Temperature, nonoperating

-40 to 158°F (-40 to 70°C)

Humidity (RH), noncondensing

5 to 95%

Altitude

0 to 10000 ft (0 to 3000 m)

Power Specifications

Cisco UCS 6300 Fabric Interconnects support AC, DC, or HVDC power supplies. You must use identical power supplies—either two AC, two DC, or two HVDC power supplies— with the fabric interconnect. In addition, if you use DC or HVDC power supplies, you must use two corresponding DC or HVDC power cords.


Note


You cannot mix power supply types in a Cisco 6300 Series Fabric Interconnect.


Table 2. Specifications for the Cisco UCS 6300 Series AC Power Supply(UCS-PSU-6332-AC)

AC Power Supply Properties

Cisco UCS 6300 Series Fabric Interconnect

Maximum output per power supply

650 W

Input voltage

100 to 240 VAC

Maximum AC input current

7.6 A @ 100 VAC

3.65 A @ 208 VAC

Maximum holdup time

12 ms @50% load

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

RoHS compliance

Yes

Hot swappable

Yes

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum Certified)

Table 3. Specifications for the Cisco UCS 6300 Series DC Power Supply (UCS-PSU-6332-DC)

DC Power Supply Properties

Cisco UCS 6300 Series Fabric Interconnect

Maximum output per power supply

930 W

Input voltage

-48 VDC

Maximum HVDC input current

23 A maximum @ -48 VDC

Maximum holdup time

8 ms @ 50% load

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

RoHS compliance

Yes

Hot swappable

Yes

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum Certified)

Table 4. Specifications for the Cisco UCS 6300 Series HVDC Power Supply (N9K-PUV-1200W)

HVDC Power Supply Properties

Cisco UCS 6300 Series Fabric Interconnect

Maximum output per power supply

1230 W

Input voltage

240 to 380 VDC

Maximum HVDC input current

6 A

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

RoHS compliance

Yes

Hot swappable

Yes

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum Certified)

Transceiver Specifications

Table 5. General Specifications for the 10-Gigabit Ethernet SFP+ Transceiver Module

Description

Short Range

Connector type

LC

Wavelength

850 nm

Core size—Cable distance

50 microns—300 m

62.5 microns—33 m

Environmental Conditions and Power Requirements Specification for SFP Transceivers

Table 6. Environmental Conditions and Power Requirements Specifications for SFP Transceivers

Parameter

Symbol

Minimum

Maximum

Storage temperature 1

TS

-40°C (-40°F)

85°C (185°F)

Case temperature 2,

TC

0°C (32°F)

70°C (158°F)

Relative humidity 2

RH

5%

95%

Module supply voltage 2

VCCT,R

3.1 V

3.5 V

1 Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period of time.
2 Functional performance is not intended, device reliability is not implied, and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions.

General Specifications for Cisco Fibre Channel SFP Transceivers

The table below lists the general specifications for Cisco Fibre Channel SFP transceivers at 4 Gbps.

Table 7. General Specifications for Cisco Fibre Channel SFP Transceivers at 4 Gbps

Description

Short Wavelength

Connector type

LC

Wavelength

850 nm

Fibre type

MMF

Core size—Cable distance

50 microns—328.08 yd (300 m)

62.5 microns—164.04 yd (150 m)

Transmit power

-9 to -2.5 dBM

3 Approximate; actual distance may vary depending on fiber quality and other factors.

Environmental Conditions and Power Requirements Specification for SFP Transceivers

Table 8. Environmental Conditions and Power Requirements Specifications for SFP Transceivers

Parameter

Symbol

Minimum

Maximum

Storage temperature 4

TS

-40°C (-40°F)

85°C (185°F)

Case temperature 2,

TC

0°C (32°F)

70°C (158°F)

Relative humidity 2

RH

5%

95%

Module supply voltage 2

VCCT,R

3.1 V

3.5 V

4 Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period of time.
5 Functional performance is not intended, device reliability is not implied, and damage to the device may occur over an extended period of time between absolute maximum ratings and the recommended operating conditions.