Viewing Server Sensors

This chapter includes the following sections:

Viewing Temperature Sensors

Procedure
     Command or ActionPurpose
    Step 1Server# scope sensor  

    Enters sensor command mode.

     
    Step 2Server /sensor # show temperature [detail]  

    Displays temperature sensor statistics for the server.

     

    This example displays temperature sensor statistics:

    Server# scope sensor
    Server /sensor # show temperature
    Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
    ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
    IOH_TEMP_SENS             Normal         32.0       C          N/A          80.0         N/A          85.0         
    P2_TEMP_SENS              Normal         31.0       C          N/A          80.0         N/A          81.0         
    P1_TEMP_SENS              Normal         34.0       C          N/A          80.0         N/A          81.0         
    DDR3_P2_D1_TMP            Normal         20.0       C          N/A          90.0         N/A          95.0         
    DDR3_P1_A1_TMP            Normal         21.0       C          N/A          90.0         N/A          95.0         
    FP_AMBIENT_TEMP           Normal         28.0       C          N/A          40.0         N/A          45.0         
    
    Server /sensor #             
    

    Viewing Voltage Sensors

    Procedure
       Command or ActionPurpose
      Step 1Server# scope sensor  

      Enters sensor command mode.

       
      Step 2Server /sensor # show voltage [detail]  

      Displays voltage sensor statistics for the server.

       

      This example displays voltage sensor statistics:

      Server# scope sensor
      Server /sensor # show voltage
      Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
      ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
      P3V_BAT_SCALED            Normal         3.022      V          N/A          N/A          2.798        3.088        
      P12V_SCALED               Normal         12.154     V          N/A          N/A          11.623       12.331       
      P5V_SCALED                Normal         5.036      V          N/A          N/A          4.844        5.157        
      P3V3_SCALED               Normal         3.318      V          N/A          N/A          3.191        3.381        
      P5V_STBY_SCALED           Normal         5.109      V          N/A          N/A          4.844        5.157        
      PV_VCCP_CPU1              Normal         0.950      V          N/A          N/A          0.725        1.391        
      PV_VCCP_CPU2              Normal         0.891      V          N/A          N/A          0.725        1.391        
      P1V5_DDR3_CPU1            Normal         1.499      V          N/A          N/A          1.450        1.548        
      P1V5_DDR3_CPU2            Normal         1.499      V          N/A          N/A          1.450        1.548        
      P1V1_IOH                  Normal         1.087      V          N/A          N/A          1.068        1.136        
      P1V8_AUX                  Normal         1.773      V          N/A          N/A          1.744        1.852        
      
      Server /sensor #             
      

      Viewing LED Sensors

      Before You Begin

      The server must be powered on, or the information will not display.

      Procedure
         Command or ActionPurpose
        Step 1Server# scope chassis  

        Enters chassis command mode.

         
        Step 2Server /chassis # show led [detail]  

        Displays the name, state, and color of the external LEDs.

         

        This example displays information about the external LEDs:

        Server# scope chassis
        Server /chassis # show led
        LED Name                  LED State  LED Color 
        ------------------------- ---------- -------- 
        LED_SYS_ACT               OFF        GREEN    
        LED_HLTH_STATUS           ON         GREEN    
        
        Server /chassis #  show led detail
        LEDs:
            LED Name: LED_SYS_ACT
            LED State: OFF
            LED Color: GREEN
        LEDs:
            LED Name: LED_HLTH_STATUS
            LED State: ON
            LED Color: GREEN
        ucs-e160dp-m1 /chassis # 
        
        

        Viewing Storage Sensors

        Procedure
           Command or ActionPurpose
          Step 1Server# scope chassis  

          Enters chassis command mode.

           
          Step 2Server /chassis # show hdd [detail]  

          Displays storage sensor information.

           

          The displayed fields are described in the following table:
          Name Description

          Name column

          The name of the storage device. This can be:

          HDDX_PRS—Indicates the presence or absence of each hard drive.

          Status column

          A brief description of the status of the storage device.

          LED Status column

          The current LED color, if any.

          To make the physical LED on the storage device blink, select Turn On from the drop-down list. To let the storage device control whether the LED blinks, select Turn Off.

          This example displays storage sensor information:

          Server# scope chassis
          Server /chassis # show hdd
          Name     		          Status 
          -------------------- -------------------- 
          HDD1_PRS 												inserted 
          HDD2_PRS 												inserted 
          HDD3_PRS 												inserted              
          
          Server /chassis #             
          

          Viewing Server Sensors

          Viewing Server Sensors

          This chapter includes the following sections:

          Viewing Temperature Sensors

          Procedure
             Command or ActionPurpose
            Step 1Server# scope sensor  

            Enters sensor command mode.

             
            Step 2Server /sensor # show temperature [detail]  

            Displays temperature sensor statistics for the server.

             

            This example displays temperature sensor statistics:

            Server# scope sensor
            Server /sensor # show temperature
            Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
            ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
            IOH_TEMP_SENS             Normal         32.0       C          N/A          80.0         N/A          85.0         
            P2_TEMP_SENS              Normal         31.0       C          N/A          80.0         N/A          81.0         
            P1_TEMP_SENS              Normal         34.0       C          N/A          80.0         N/A          81.0         
            DDR3_P2_D1_TMP            Normal         20.0       C          N/A          90.0         N/A          95.0         
            DDR3_P1_A1_TMP            Normal         21.0       C          N/A          90.0         N/A          95.0         
            FP_AMBIENT_TEMP           Normal         28.0       C          N/A          40.0         N/A          45.0         
            
            Server /sensor #             
            

            Viewing Voltage Sensors

            Procedure
               Command or ActionPurpose
              Step 1Server# scope sensor  

              Enters sensor command mode.

               
              Step 2Server /sensor # show voltage [detail]  

              Displays voltage sensor statistics for the server.

               

              This example displays voltage sensor statistics:

              Server# scope sensor
              Server /sensor # show voltage
              Name                      Sensor Status  Reading    Units      Min. Warning Max. Warning Min. Failure Max. Failure 
              ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ 
              P3V_BAT_SCALED            Normal         3.022      V          N/A          N/A          2.798        3.088        
              P12V_SCALED               Normal         12.154     V          N/A          N/A          11.623       12.331       
              P5V_SCALED                Normal         5.036      V          N/A          N/A          4.844        5.157        
              P3V3_SCALED               Normal         3.318      V          N/A          N/A          3.191        3.381        
              P5V_STBY_SCALED           Normal         5.109      V          N/A          N/A          4.844        5.157        
              PV_VCCP_CPU1              Normal         0.950      V          N/A          N/A          0.725        1.391        
              PV_VCCP_CPU2              Normal         0.891      V          N/A          N/A          0.725        1.391        
              P1V5_DDR3_CPU1            Normal         1.499      V          N/A          N/A          1.450        1.548        
              P1V5_DDR3_CPU2            Normal         1.499      V          N/A          N/A          1.450        1.548        
              P1V1_IOH                  Normal         1.087      V          N/A          N/A          1.068        1.136        
              P1V8_AUX                  Normal         1.773      V          N/A          N/A          1.744        1.852        
              
              Server /sensor #             
              

              Viewing LED Sensors

              Before You Begin

              The server must be powered on, or the information will not display.

              Procedure
                 Command or ActionPurpose
                Step 1Server# scope chassis  

                Enters chassis command mode.

                 
                Step 2Server /chassis # show led [detail]  

                Displays the name, state, and color of the external LEDs.

                 

                This example displays information about the external LEDs:

                Server# scope chassis
                Server /chassis # show led
                LED Name                  LED State  LED Color 
                ------------------------- ---------- -------- 
                LED_SYS_ACT               OFF        GREEN    
                LED_HLTH_STATUS           ON         GREEN    
                
                Server /chassis #  show led detail
                LEDs:
                    LED Name: LED_SYS_ACT
                    LED State: OFF
                    LED Color: GREEN
                LEDs:
                    LED Name: LED_HLTH_STATUS
                    LED State: ON
                    LED Color: GREEN
                ucs-e160dp-m1 /chassis # 
                
                

                Viewing Storage Sensors

                Procedure
                   Command or ActionPurpose
                  Step 1Server# scope chassis  

                  Enters chassis command mode.

                   
                  Step 2Server /chassis # show hdd [detail]  

                  Displays storage sensor information.

                   

                  The displayed fields are described in the following table:
                  Name Description

                  Name column

                  The name of the storage device. This can be:

                  HDDX_PRS—Indicates the presence or absence of each hard drive.

                  Status column

                  A brief description of the status of the storage device.

                  LED Status column

                  The current LED color, if any.

                  To make the physical LED on the storage device blink, select Turn On from the drop-down list. To let the storage device control whether the LED blinks, select Turn Off.

                  This example displays storage sensor information:

                  Server# scope chassis
                  Server /chassis # show hdd
                  Name     		          Status 
                  -------------------- -------------------- 
                  HDD1_PRS 												inserted 
                  HDD2_PRS 												inserted 
                  HDD3_PRS 												inserted              
                  
                  Server /chassis #