Technical Specifications

Switch Specifications

Power-Supply Module Specifications

Alarm Ratings

Switch Specifications

 

Table 13 Environmental and Physical Specifications

Environmental Ranges

Operating temperature1

-40C to +74C

-40C to +70C (Vented Enclosure Operating)

-40C to +60C (Sealed Enclosure Operating)

-34C to +74C (100LFM or more Fan or Blower equipped Enclosure Operating)

-40C to +85C (Type Tested to +85C for 16 hours) 2

Storage temperature

–40 to 185°F (–40 to 85°C)

Relative humidity

5 to 95% (noncondensing)

Operating altitude

Up to 10,000 ft (3049 m)

Storage altitude

Up to 15,000 ft (4570 m)

Thermal spacing

1.75 in. (4.4 cm)

Operating shock

30 g at 11 ms

Physical Specifications

Weight

Cisco IE-3010-24TC

Cisco IE-3010-16S-8PC

 

9.1 lb (4.1 kg) (no power-supply module)

10 lb (4.5 kg) (no power-supply module)

Dimensions (H x W x D)

Cisco IE-3010-24TC

Cisco IE-3010-16S-8PC

 

1.75 x 17.5 x 14.0 in. (4.45 x 44.5 x 35.6 cm)

1.75 x 17.5 x 14.0 in. (4.45 x 44.5 x 35.6 cm)

1.Operating temperatures exceeding 60C are not covered by the product safety certifications and approvals. However, the switch can function in the installations under the environmental conditions listed.

2.The maximum operating temperature of the switch varies depending on the type of SFP module that you use.

 

Table 14 Technical Specifications for the Cisco IE 3010-16S-8PC Switch

Power Requirements

Nominal input voltage

PWR-RGD-AC-DC/IA:

100 to 240 VAC, 50 to 60 Hz

100 to 250 VDC

PWR-RGD-LOW-DC/IA:

24 to 60 VDC

Absolute maximum (short term) input voltage

PWR-RGD-AC-DC/IA:

85 to 265 VAC, 47 to 63 Hz

88 to 300 VDC

PWR-RGD-LOW-DC/IA:

18 to 75 VDC

Power consumption with one PWR-RGD-AC-DC/IA power-supply module

AC: 147 BTUs per hour

43.2 W

Power rating: 0.044 KVA@115 V

DC: 137 BTUs per hour

40.3 W

Power rating: 0.0403 KVA@125 VDC

Power consumption with one PWR-RGD-AC-DC/IA power-supply module (with PoE on 4 ports)

AC: 376 BTUs per hour

110.1 W

Power rating 0.11 KVA@115 V

DC: 375 BTUs per hour

109.8 W

Power rating: 0.109 KVA@125 VDC

Power consumption with two PWR-RGD-AC-DC/IA power-supply modules

AC: 166 BTUs per hour

48.8 W

Power rating: 0.051 KVA@115 V

DC: 167 BTUs per hour

48.9 W

Power rating: 0.0489 KVA@125 VDC

Power consumption with two PWR-RGD-AC-DC/IA power-supply modules (with PoE on 8 ports)

AC: 628 BTUs per hour

184.1 W

Power rating: 0.185 KVA@115 V

DC: 622 BTUs per hour

182.2 W

Power rating: 0.182 KVA@125 VDC

Power consumption with one PWR-RGD-LOW-DC/IA power-supply module

DC: 116 BTUs per hour

34.2 W

Power rating: 0.034 KVA@24 VDC

Power consumption with one PWR-RGD-LOW-DC/IA power-supply module (with PoE on 4 ports)

DC: 363 BTUs per hour

106 W

Power rating: 0.106 KVA@24 VDC

Power consumption with two PWR-RGD-LOW-DC/IA power-supply modules

DC: 127 BTUs per hour

37.1 W

Power rating: 0.037 KVA@24 VDC

Power consumption with two PWR-RGD-LOW-DC/IA power-supply modules (with PoE on 8 ports)

DC: 622 BTUs per hour

181.9 W

Power rating: 0.182 KVA@24 VDC

 

Table 15 Technical Specifications for the Cisco IE-3010-24TC Switch

Power Requirements

Nominal input voltage

PWR-RGD-AC-DC/IA:

100 to 240 VAC, 50 to 60 Hz

100 to 250 VDC

PWR-RGD-LOW-DC/IA:

24 to 60 VDC

Absolute maximum (short term) input voltage

PWR-RGD-AC-DC/IA:

85 to 265 VAC, 47 to 63 Hz

88 to 300 VDC

PWR-RGD-LOW-DC/IA:

18 to 75 VDC

Power consumption with one PWR-RGD-AC-DC/IA power-supply module

AC: 102 BTUs per hour

29.8 W

Power rating: 0.031 KVA@115 V

DC: 98 BTUs per hour

28.6 W

Power rating: 0.0286 KVA@125 VDC

Power consumption with two PWR-RGD-AC-DC/IA power-supply modules

AC: 121 BTUs per hour

35.5 W

Power rating: 0.0367 KVA@115 V

DC: 117 BTUs per hour

34.4 W

Power rating: 0.0344 KVA@ 125 VDC

Power consumption with one PWR-RGD-LOW-DC/IA power-supply module

DC: 92 BTUs per hour

26.8 W

Power rating: 0.027 KVA@ 24 VDC

Power consumption with two PWR-RGD-LOW-DC/IA power-supply modules

DC: 105 BTUs per hour

30.7 W

Power rating: 0.030 KVA@ 24 VDC

Power-Supply Module Specifications

 

Table 16 Environmental and Physical Specifications for the AC- and DC-Power-Supply Modules

Environmental Ranges

Operating temperature

–40 to 140°F (–40 to 60°C)

Storage temperature

–49 to 185°F (–45 to 85°C)

Relative humidity

5 to 95% (noncondensing)

Altitude

Up to 10,000 ft (3049 m)

Physical Specifications

Weight

PWR-RGD-AC-DC/IA

PWR-RGD-LOW-DC/IA

 

2.55 lb (1.15 kg)

2.5 lb (1.13 kg)

Dimensions (H x W x D)

PWR-RGD-AC-DC/IA

PWR-RGD-LOW-DC/IA

 

1.58 x 7 x 5 in. (4 x 17.8 x 12.7 cm) (without mounting flanges)

1.58 x 8.15 x 5 in. (4 x 20.7 x 12.7 cm) (with mounting flanges)

 

Table 17 Technical Specifications for the PWR-RGD-AC-DC/IA Power-Supply Module

Power Specifications

Maximum output power

150 W

Nominal input voltage

100 to 240 VAC, 50 to 60 Hz

100 to 250 VDC

Absolute maximum (short term) input voltage

85 to 265 VAC, 47 to 63 Hz

88 to 300 VDC

Input current

AC: 2.2 to 0.7 A, 85 to 265 VAC

DC: 2.5 to 0.6 A, 88 to 300 VDC

Total input BTU

AC: 638 BTUs per hour

DC: 750 BTUs per hour

 

Table 18 Technical Specifications for the PWR-RGD-LOW-DC/IA Power-Supply Module

Power Specifications

Maximum output power

150 W

Nominal input voltage

24 to 60 VDC

Absolute maximum (short term) input voltage

18 to 75 VDC

Input current

12 to 2.5 A, 18 to 75 VDC

Total input BTU

737 BTUs per hour

Alarm Ratings

Table 19 Alarm Input and Output Ratings

 

Alarm Ratings

Alarm input electrical specification

8 V @ 1mA

Alarm output electrical specification

30 V @ 1A

Note: The alarm output does not support AC voltage because the RJ-45 connector pin spacing is too small.