show access-group mode interface
To display the ACL configuration on a Layer 2 interface, use the show access-group mode interface command.
show access-group mode interface [interface interface-number]
Syntax Description
interface |
(Optional) Interface type; valid values are ethernet, fastethernet, gigabitethernet, tengigabitethernet, and port-channel. |
interface-number |
(Optional) Interface number. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Support for the 10-Gigabit Ethernet interface was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The valid values for the port number depend on the chassis used.
Examples
This example shows how to display the ACL configuration on the Fast Ethernet interface 6/1:
Switch# show access-group mode interface fa6/1
Interface FastEthernet6/1:
Access group mode is: merge
Related Commands
access-group mode
show adjacency
To display information about the Layer 3 switching adjacency table, use the show adjacency command.
show adjacency [{interface interface-number} | {null interface-number} | {port-channel number} | {vlan vlan-id} | detail | internal | summary]
Syntax Description
interface |
(Optional) Interface type; possible valid values are ethernet, fastethernet, gigabitethernet, tengigabitethernet, pos, ge-wan, and atm. |
interface-number |
(Optional) Module and port number; see the "Usage Guidelines" section for valid values. |
null interface-number |
(Optional) Specifies the null interface; the valid value is 0. |
port-channel number |
(Optional) Specifies the channel interface; valid values are a maximum of 64 values ranging from 1 to 256. |
vlan vlan-id |
(Optional) Specifies the VLAN; valid values are from 1 to 4094. |
detail |
(Optional) Displays the information about the protocol detail and timer. |
internal |
(Optional) Displays the information about the internal data structure. |
summary |
(Optional) Displays a summary of CEF-adjacency information. |
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.2(25)EW |
Extended to include the 10-Gigabit Ethernet interface. |
Usage Guidelines
The interface-number argument designates the module and port number. Valid values for interface-number depend on the specified interface type and the chassis and module that are used. For example, if you specify a Gigabit Ethernet interface and have a 48-port 10/100BASE-T Ethernet module that is installed in a 13-slot chassis, valid values for the module number are from 1 to 13, and valid values for the port number are from 1 to 48.
Hardware Layer 3 switching adjacency statistics are updated every 60 seconds.
The following information is contained in the show adjacency command:
•
Protocol interface.
•
Type of routing protocol that is configured on the interface.
•
Interface address.
•
Method of adjacency that was learned.
•
MAC address of the adjacent router.
•
Time left before the adjacency rolls out of the adjacency table. After it rolls out, a packet must use the same next hop to the destination.
Examples
This example shows how to display adjacency information:
Protocol Interface Address
IP FastEthernet2/3 172.20.52.1(3045)
IP FastEthernet2/3 172.20.52.22(11)
This example shows how to display a summary of adjacency information:
Switch# show adjacency summary
Adjacency Table has 2 adjacencies
Interface Adjacency Count
This example shows how to display protocol detail and timer information:
Switch# show adjacency detail
Protocol Interface Address
IP FastEthernet2/3 172.20.52.1(3045)
000000000FF920000380000000000000
00000000000000000000000000000000
00605C865B2800D0BB0F980B0800
IP FastEthernet2/3 172.20.52.22(11)
000000000FF920000380000000000000
00000000000000000000000000000000
00801C93804000D0BB0F980B0800
This example shows how to display adjacency information for a specific interface:
Switch# show adjacency fastethernet2/3
Protocol Interface Address
IP FastEthernet2/3 172.20.52.1(3045)
IP FastEthernet2/3 172.20.52.22(11)
Related Commands
debug adjacency
show arp access-list
To display detailed information on an ARP access list, use the show arp command.
show arp access-list
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the ARP ACL information for a switch:
Switch# show arp access-list
permit ip 10.101.1.1 0.0.0.255 mac any
permit ip 20.3.1.0 0.0.0.255 mac any
Related Commands
access-group mode
arp access-list
ip arp inspection filter vlan
show auto install status
To display the status of an automatic installation, use the show auto install status command.
show auto install status
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.2(20)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the IP address of the TFTP server and to display whether or not the switch is currently acquiring the configuration file on the TFTP server:
Switch# show auto install status
Status : Downloading config file
Config File Fetched : Undetermined
The first IP address in the display indicates the server that is used for the automatic installation. The second IP address indicates the TFTP server that provided the configuration file.
show auto qos
To display the automatic quality of service (auto-QoS) configuration that is applied, use the show auto qos user EXEC command.
show auto qos [interface [interface-id]] [{begin | exclude | include} expression]
Syntax Description
interface interface-id |
(Optional) Displays auto-QoS information for the specified interface or for all interfaces. Valid interfaces include physical ports. |
begin |
(Optional) Begins with the line that matches the expression. |
exclude |
(Optional) Excludes lines that match the expression. |
include |
(Optional) Includes lines that match the specified expression. |
expression |
(Optional) Expression in the output to use as a reference point. |
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The show auto qos interface interface-id command displays the auto-QoS configuration; it does not display any user changes to the configuration that might be in effect.
To display information about the QoS configuration that might be affected by auto-QoS, use one of these commands:
•
show qos
•
show qos map
•
show qos interface interface-id
•
show running-config
Expressions are case sensitive. For example, if you enter exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This example shows output from the show auto qos command when auto-QoS is enabled:
00:00:56:qos map cos 3 to dscp 26
00:00:57:qos map cos 5 to dscp 46
00:00:58:qos map dscp 16 to tx-queue 1
00:00:58:qos map dscp 32 to tx-queue 1
00:00:59:policy-map autoqos-voip-policy
00:00:59: class class-default
00:00:59:interface GigabitEthernet1/1
00:00:59: qos trust device cisco-phone
00:00:59: shape percent 70
00:00:59: service-policy output autoqos-voip-policyend
This example shows output from the show auto qos interface command when the auto qos voip cisco-phone interface configuration command is entered:
Switch# show auto qos interface
Initial configuration applied by AutoQoS:
interface GigabitEthernet1/1
qos trust device cisco-phone
service-policy output autoqos-voip-policy
interface GigabitEthernet1/2
qos trust device cisco-phone
service-policy output autoqos-voip-policy
This example shows output from the show auto qos interface gigabitethernet1/1 command when the auto qos voip cisco-phone interface configuration command is entered:
Switch# show auto qos interface gigabitethernet1/1
Initial configuration applied by AutoQoS:
interface GigabitEthernet1/1
qos trust device cisco-phone
service-policy output autoqos-voip-policy
This example shows output from the show auto qos command when auto-QoS is disabled:
Related Commands
auto qos voip
show bootflash:
To display information about the bootflash: file system, use the show bootflash: command.
show bootflash: [all | chips | filesys]
Syntax Description
all |
(Optional) Displays all possible Flash information. |
chips |
(Optional) Displays Flash chip information. |
filesys |
(Optional) Displays file system information. |
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display file system status information:
Switch>
show bootflash: filesys
-------- F I L E S Y S T E M S T A T U S --------
DEVICE INFO BLOCK: bootflash
Magic Number = 6887635 File System Vers = 10000 (1.0)
Length = 1000000 Sector Size = 40000
Programming Algorithm = 39 Erased State = FFFFFFFF
File System Offset = 40000 Length = F40000
MONLIB Offset = 100 Length = C628
Bad Sector Map Offset = 3FFF8 Length = 8
Squeeze Log Offset = F80000 Length = 40000
Squeeze Buffer Offset = FC0000 Length = 40000
Bytes Used = 917CE8 Bytes Available = 628318
Bad Sectors = 0 Spared Sectors = 0
OK Files = 2 Bytes = 917BE8
Deleted Files = 0 Bytes = 0
Files w/Errors = 0 Bytes = 0
This example shows how to display system image information:
-# - ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. image 8C5A393A 237E3C 14 2063804 Aug 23 1999 16:18:45 c4-boot-mz
2 .. image D86EE0AD 957CE8 9 7470636 Sep 20 1999 13:48:49 rp.halley
This example shows how to display all bootflash information:
Switch>
show bootflash: all
-# - ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. image 8C5A393A 237E3C 14 2063804 Aug 23 1999 16:18:45 c4-boot-
2 .. image D86EE0AD 957CE8 9 7470636 Sep 20 1999 13:48:49 rp.halley
6456088 bytes available (9534696 bytes used)
-------- F I L E S Y S T E M S T A T U S --------
DEVICE INFO BLOCK: bootflash
Magic Number = 6887635 File System Vers = 10000 (1.0)
Length = 1000000 Sector Size = 40000
Programming Algorithm = 39 Erased State = FFFFFFFF
File System Offset = 40000 Length = F40000
MONLIB Offset = 100 Length = C628
Bad Sector Map Offset = 3FFF8 Length = 8
Squeeze Log Offset = F80000 Length = 40000
Squeeze Buffer Offset = FC0000 Length = 40000
Bytes Used = 917CE8 Bytes Available = 628318
Bad Sectors = 0 Spared Sectors = 0
OK Files = 2 Bytes = 917BE8
Deleted Files = 0 Bytes = 0
Files w/Errors = 0 Bytes = 0
show bootvar
To display BOOT environment variable information, use the show bootvar command.
show bootvar
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display BOOT environment variable information:
CONFIG_FILE variable does not exist
BOOTLDR variable does not exist
Configuration register is 0x0
show cable-diagnostics tdr
To display the test results for the TDR cable diagnostics, use the show cable-diagnostics tdr command.
show cable-diagnostics tdr {interface {interface interface-number}}
Note
This command will be deprecated in future Cisco IOS releases. Please use the diagnostic start command.
Syntax Description
interface interface |
Interface type; valid values are fastethernet and gigabitethernet. |
interface-number |
Module and port number. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.2(25)SG |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The TDR test is supported on Catalyst 4500 series switches running Cisco IOS Release 12.2(25)SG for the following line cards only:
•
WS-X4548-GB-RJ45
•
WS-X4548-GB-RJ45V
•
WS-X4524-GB-RJ45V
•
WS-X4013+TS
•
WS-C4948
•
WS-C4948-10GE
The distance to the fault is displayed in meters (m).
Examples
This example shows how to display information about the TDR test:
Switch# show cable-diagnostics tdr interface gi4/13
Interface Speed Local pair Cable length Remote channel Status
Gi4/13 0Mbps 1-2 102 +-2m Unknown Fault
3-6 100 +-2m Unknown Fault
4-5 102 +-2m Unknown Fault
7-8 102 +-2m Unknown Fault
Table 2-13 describes the fields in the show cable-diagnostics tdr command output.
Table 2-13 show cable-diagnostics tdr Command Output Fields
|
|
Interface |
Interface tested. |
Speed |
Current line speed. |
Pair |
Local pair name. |
Cable Length |
Distance to the fault in meters (m). |
Channel |
Pair designation (A, B, C, or D). |
Status |
Pair status displayed is one of the following: • Terminated—The link is up. • Fault—Cable fault (open or short) |
Related Commands
test cable-diagnostics tdr
show cdp neighbors
To display detailed information about the neighboring devices that are discovered through CDP, use the show cdp neighbors command.
show cdp neighbors [type number] [detail]
Syntax Description
type |
(Optional) Interface type that is connected to the neighbors about which you want information; possible valid values are ethernet, fastethernet, gigabitethernet, tengigabitethernet, port-channel, and vlan. |
number |
(Optional) Interface number that is connected to the neighbors about which you want information. |
detail |
(Optional) Displays detailed information about a neighbor (or neighbors) including network address, enabled protocols, hold time, and software version. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.2(25)EW |
Extended to include the 10-Gigabit Ethernet interface. |
Usage Guidelines
The vlan keyword is supported in Catalyst 4500 series switches that are configured with a Supervisor Engine II.
The port-channel values are from 0 to 282; values from 257 to 282 are supported on the CSM and the FWSM only.
Examples
This example shows how to display the information about the CDP neighbors:
Switch# show cdp neighbors
Capability Codes: R - Router, T - Trans Bridge, B - Source Route Bridge
S - Switch, H - Host, I - IGMP, r - Repeater, P - Phone
Device ID Local Intrfce Holdtme Capability Platform Port ID
lab-7206 Eth 0 157 R 7206VXR Fas 0/0/0
lab-as5300-1 Eth 0 163 R AS5300 Fas 0
lab-as5300-2 Eth 0 159 R AS5300 Eth 0
lab-as5300-3 Eth 0 122 R AS5300 Eth 0
lab-as5300-4 Eth 0 132 R AS5300 Fas 0/0
lab-3621 Eth 0 140 R S 3631-telcoFas 0/0
008024 2758E0 Eth 0 132 T CAT3000 1/2
Table 2-14 describes the fields that are shown in the example.
Table 2-14 show cdp neighbors Field Descriptions
|
|
Device ID |
Configured ID (name), MAC address, or serial number of the neighbor device. |
Local Intrfce |
(Local Interface) The protocol that is used by the connectivity media. |
Holdtme |
(Holdtime) Remaining amount of time, in seconds, that the current device holds the CDP advertisement from a transmitting router before discarding it. |
Capability |
Capability code that is discovered on the device. This device type is listed in the CDP Neighbors table. Possible values are as follows: R—Router T—Transparent bridge B—Source-routing bridge S—Switch H—Host I—IGMP device r—Repeater P—Phone |
Platform |
Product number of the device. |
Port ID |
Protocol and port number of the device. |
This example shows how to display detailed information about your CDP neighbors:
Switch# show cdp neighbors detail
-------------------------
IP address: 172.19.169.83
Platform: cisco 7206VXR, Capabilities: Router
Interface: Ethernet0, Port ID (outgoing port): FastEthernet0/0/0
Cisco Internetwork Operating System Software
IOS (tm) 5800 Software (C5800-P4-M), Version 12.1(2)
Copyright (c) 1986-2002 by Cisco Systems, Inc.
-------------------------
IP address: 172.19.169.87
Table 2-15 describes the fields that are shown in the example.
Table 2-15 show cdp neighbors detail Field Descriptions
|
|
Device ID |
Name of the neighbor device and either the MAC address or the serial number of this device. |
Entry address(es) |
List of network addresses of neighbor devices. |
[network protocol] address |
Network address of the neighbor device. The address can be in IP, IPX, AppleTalk, DECnet, or CLNS protocol conventions. |
Platform |
Product name and number of the neighbor device. |
Capabilities |
Device type of the neighbor. This device can be a router, a bridge, a transparent bridge, a source-routing bridge, a switch, a host, an IGMP device, or a repeater. |
Interface |
Protocol and port number of the port on the current device. |
Holdtime |
Remaining amount of time, in seconds, that the current device holds the CDP advertisement from a transmitting router before discarding it. |
Version: |
Software version running on the neighbor device. |
advertisement version: |
Version of CDP that is being used for CDP advertisements. |
Duplex: |
Duplex state of connection between the current device and the neighbor device. |
Related Commands
show cdp (refer to Cisco IOS documentation)
show cdp entry (refer to Cisco IOS documentation)
show cdp interface (refer to Cisco IOS documentation)
show cdp traffic (refer to Cisco IOS documentation)
show class-map
To display class map information, use the show class-map command.
show class-map class_name
Syntax Description
class_name |
Name of the class map. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)SG |
Displays results from the full flow option. |
Examples
This example shows how to display class map information for all class maps:
Class Map match-any class-default (id 0)
Class Map match-any class-simple (id 2)
Class Map match-all ipp5 (id 1)
Class Map match-all agg-2 (id 3)
This example shows how to display class map information for a specific class map:
Switch# show class-map ipp5
Class Map match-all ipp5 (id 1)
Assume there are two active flows as shown below on Fast Ethernet interface 6/1:
SrcIp DstIp IpProt SrcL4Port DstL4Port
--------------------------------------------------------
192.168.10.10 192.168.20.20 20 6789 81
192.168.10.10 192.168.20.20 20 6789 21
With following configuration, each flow will be policed to a 1000000 bps with an allowed 9000-byte burst value.
Note
If you use the match flow ip source-address|destination-address command, these two flows are consolidated into one flow and they have the same source and destination address.
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)# class-map c1
Switch(config-cmap)# match flow ip source-address ip destination-address ip protocol l4
source-port l4 destination-port
Switch(config-cmap)# exit
Switch(config)# policy-map p1
Switch(config-pmap)# class c1
Switch(config-pmap-c)# police 1000000 9000
Switch(config-pmap-c)# exit
Switch(config-pmap)# exit
Switch(config)# interface fastEthernet 6/1
Switch(config-if)# service-policy input p1
Switch# show policy-map interface
match flow ip source-address ip destination-address ip protocol l4 source-port l4
destination-port
police 1000000 bps 9000 byte conform-action transmit exceed-action drop
interface FastEthernet 6/1
Switch# show class-map c1
Class Map match-all c1 (id 2)
Match flow ip source-address ip destination-address ip protocol l4 source-port l4
destination-port
Related Commands
class-map
show policy-map
show policy-map interface
show diagnostic content
To display test information about the test ID, test attributes, and supported coverage test levels for each test and for all modules, use the show diagnostic content command.
show diagnostic content module {all | num}
Syntax Description
all |
Displays all the modules on the chassis. |
num |
Module number. |
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.2(20)EWA |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the test suite, monitoring interval, and test attributes for all the modules of the chassis:
Switch# show diagnostic content module all
Diagnostics test suite attributes:
B/* - Basic ondemand test / NA
P/V/* - Per port test / Per device test / NA
D/N/* - Disruptive test / Non-disruptive test / NA
S/* - Only applicable to standby unit / NA
X/* - Not a health monitoring test / NA
F/* - Fixed monitoring interval test / NA
E/* - Always enabled monitoring test / NA
A/I - Monitoring is active / Monitoring is inactive
m/* - Mandatory bootup test, can't be bypassed / NA
o/* - Ongoing test, always active / NA
ID Test Name Attributes (day hh:mm:ss.ms)
==== ========================================== ============ =================
1) supervisor-bootup -----------------------> **D****I** not configured
2) packet-memory-bootup --------------------> **D****I** not configured
3) packet-memory-ongoing -------------------> **N****I*o not configured
Diagnostics test suite attributes:
B/* - Basic ondemand test / NA
P/V/* - Per port test / Per device test / NA
D/N/* - Disruptive test / Non-disruptive test / NA
S/* - Only applicable to standby unit / NA
X/* - Not a health monitoring test / NA
F/* - Fixed monitoring interval test / NA
E/* - Always enabled monitoring test / NA
A/I - Monitoring is active / Monitoring is inactive
m/* - Mandatory bootup test, can't be bypassed / NA
o/* - Ongoing test, always active / NA
ID Test Name Attributes (day hh:mm:ss.ms)
==== ========================================== ============ =================
1) linecard-online-diag --------------------> **D****I** not configured
Related Commands
show diagnostic result module
show diagnostic result module test 2
show diagnostic result module test 3
show diagnostic result module
To display the module-based diagnostic test results, use the show diagnostic result module command.
show diagnostic result module [slot-num | all] [test [test-id | test-id-range | all]] [detail]
Syntax Description
slot-num |
(Optional) Specifies the slot on which diagnostics are displayed. |
all |
(Optional) Displays the diagnostics for all slots. |
test |
(Optional) Displays selected tests on the specified module. |
test-id |
(Optional) Specifies a single test ID. |
test-id-range |
(Optional) Specifies a range of test IDs. |
all |
(Optional) Displays the diagnostics for all tests. |
detail |
(Optional) Displays the complete test results. |
Defaults
A summary of the test results for all modules in the chassis is displayed.
Command Modes
Privileged EXEC
Command History
|
|
12.2(18)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the summary results for all modules in the chassis:
Switch# show diagnostic result module
Current bootup diagnostic level: minimal
Overall diagnostic result: PASS
Diagnostic level at card bootup: bypass
Test results: (. = Pass, F = Fail, U = Untested)
1) supervisor-bootup -----------------------> U
2) packet-memory-bootup --------------------> U
3) packet-memory-ongoing -------------------> U
Overall diagnostic result: PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) linecard-online-diag --------------------> .
Overall diagnostic result: PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) linecard-online-diag --------------------> .
Overall diagnostic result: PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) linecard-online-diag --------------------> .
This example shows how to display the online diagnostics for module 1:
Switch# show diagnostic result module 1 detail
Current bootup diagnostic level: minimal
Overall diagnostic result: PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
1) supervisor-bootup -----------------------> .
Error code --------------------------> 0 (DIAG_SUCCESS)
Total run count ---------------------> 0
Last test execution time ------------> n/a
First test failure time -------------> n/a
Last test failure time --------------> n/a
Last test pass time -----------------> n/a
Total failure count -----------------> 0
Consecutive failure count -----------> 0
Power-On-Self-Test Results for ACTIVE Supervisor
Power-on-self-test for Module 1: WS-X4014
Port/Test Status: (. = Pass, F = Fail)
Reset Reason: PowerUp Software/User
Port Traffic: L2 Serdes Loopback ...
0: . 1: . 2: . 3: . 4: . 5: . 6: . 7: . 8: . 9: . 10: . 11: .
12: . 13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: .
24: . 25: . 26: . 27: . 28: . 29: . 30: . 31: .
Port Traffic: L2 Asic Loopback ...
0: . 1: . 2: . 3: . 4: . 5: . 6: . 7: . 8: . 9: . 10: . 11: .
12: . 13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: .
24: . 25: . 26: . 27: . 28: . 29: . 30: . 31: .
Port Traffic: L3 Asic Loopback ...
0: . 1: . 2: . 3: . 4: . 5: . 6: . 7: . 8: . 9: . 10: . 11: .
12: . 13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: .
24: . 25: . 26: . 27: . 28: . 29: . 30: . 31: . au: .
Switch Subsystem Memory ...
1: . 2: . 3: . 4: . 5: . 6: . 7: . 8: . 9: . 10: . 11: . 12: .
13: . 14: . 15: . 16: . 17: . 18: . 19: . 20: . 21: . 22: . 23: . 24: .
25: . 26: . 27: . 28: . 29: . 30: . 31: . 32: . 33: . 34: . 35: . 36: .
37: . 38: . 39: . 40: . 41: . 42: . 43: . 44: . 45: . 46: . 47: . 48: .
49: . 50: . 51: . 52: . 53: . 54: .
___________________________________________________________________________
2) packet-memory-bootup --------------------> .
Error code --------------------------> 0 (DIAG_SUCCESS)
Total run count ---------------------> 0
Last test execution time ------------> n/a
First test failure time -------------> n/a
Last test failure time --------------> n/a
Last test pass time -----------------> n/a
Total failure count -----------------> 0
Consecutive failure count -----------> 0
packet buffers on free list: 64557 bad: 0 used for ongoing tests: 979
Number of errors found: 0
Cells with hard errors (failed two or more tests): 0
Cells with soft errors (failed one test, includes hard): 0
Suspect bad cells (uses a block that tested bad): 0
good buffers: 65536 (100.0%)
___________________________________________________________________________
3) packet-memory-ongoing -------------------> U
Error code --------------------------> 0 (DIAG_SUCCESS)
Total run count ---------------------> 0
Last test execution time ------------> n/a
First test failure time -------------> n/a
Last test failure time --------------> n/a
Last test pass time -----------------> n/a
Total failure count -----------------> 0
Consecutive failure count -----------> 0
packet buffers on free list: 64557 bad: 0 used for ongoing tests: 979
Packet memory errors: 0 0
Current alert level: green
Per 5 seconds in the last minute:
Per minute in the last hour:
Per hour in the last day:
Per day in the last 30 days:
Direct memory test failures per minute in the last hour:
Potential false positives: 0 0
Ignored because of rx errors: 0 0
Ignored because of cdm fifo overrun: 0 0
Ignored because of oir: 0 0
Ignored because isl frames received: 0 0
Ignored after writing hw stats: 0 0
Ignored on high gigaport: 0
Ongoing diag action mode: Normal
Last 1000 Memory Test Failures:
Last 1000 Packet Memory errors:
First 1000 Packet Memory errors:
___________________________________________________________________________
show diagnostic result module test
To display the results of the bootup packet memory test, use the show diagnostic result module test command. The output indicates whether the test passed, failed, or was not run.
show diagnostic result module [N | all] [test test-id] [detail]
Syntax Description
N |
Specifies the module number. |
all |
Specifies all modules. |
test test-id |
Specifies the number for the tdr test on the platform. |
detail |
(Optional) Specifies the display of detailed information for analysis. This option is recommended. |
Defaults
Non-detailed results
Command Modes
EXEC mode
Command History
|
|
12.2(25)SG |
This command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The detail keyword is intended for use by Cisco support personnel when analyzing failures.
Examples
This example shows how to display the results of the bootup packet memory tests:
Switch# show diagnostic result module 6 detail
Overall diagnostic result:PASS
Test results:(. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
1) linecard-online-diag --------------------> .
Error code --------------------------> 0 (DIAG_SUCCESS)
Total run count ---------------------> 1
Last test execution time ------------> Jan 21 2001 19:48:30
First test failure time -------------> n/a
Last test failure time --------------> n/a
Last test pass time -----------------> Jan 21 2001 19:48:30
Total failure count -----------------> 0
Consecutive failure count -----------> 0
Slot Ports Card Type Diag Status Diag Details
---- ----- -------------------------------------- ---------------- ------------
6 48 10/100/1000BaseT (RJ45)V, Cisco/IEEE Passed None
L = Loopback failure S = Stub failure
I = Ilc failure P = Port failure
E = SEEPROM failure G = GBIC integrity check failure
Ports 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
. . . . . . . . . . . . . . . .
Ports 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
. . . . . . . . . . . . . . . .
Ports 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
. . . . . . . . . . . . . . . .
___________________________________________________________________________
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
. U U U U U U U U U U U U U U U U U U U U U U U
Port 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
Error code --------------------------> 0 (DIAG_SUCCESS)
Total run count ---------------------> 1
Last test execution time ------------> Jan 22 2001 03:01:54
First test failure time -------------> n/a
Last test failure time --------------> n/a
Last test pass time -----------------> Jan 22 2001 03:01:54
Total failure count -----------------> 0
Consecutive failure count -----------> 0
TDR test is in progress on interface Gi6/1
___________________________________________________________________________
Related Commands
diagnostic start
show diagnostic result module test 2
To display the results of the bootup packet memory test, use the show diagnostic result module test 2 command. The output indicates whether the test passed, failed, or was not run.
show diagnostic result module N test 2 [detail]
Syntax Description
N |
Specifies the module number. |
detail |
(Optional) Specifies the display of detailed information for analysis. |
Defaults
Non-detailed results
Command Modes
EXEC mode
Command History
|
|
12.2(18)EW |
This command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The detail keyword is intended for use by Cisco support personnel when analyzing failures.
Examples
This example shows how to display the results of the bootup packet memory tests:
Switch# show diagnostic result module 1 test 2
Test results: (. = Pass, F = Fail, U = Untested)
2) packet-memory-bootup ------------> .
This example shows how to display detailed results from the bootup packet memory tests:
Switch# show diagnostic result module 2 test 2 detail
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
2) packet-memory-bootup ------------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 0
Last test execution time ----> n/a
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> n/a
Total failure count ---------> 0
Consecutive failure count ---> 0
packet buffers on free list: 64557 bad: 0 used for ongoing tests: 979
Number of errors found: 0
Cells with hard errors (failed two or more tests): 0
Cells with soft errors (failed one test, includes hard): 0
Suspect bad cells (uses a block that tested bad): 0
good buffers: 65536 (100.0%)
Related Commands
diagnostic monitor action
show diagnostic result module test 3
show diagnostic result module test 3
To display the results from the ongoing packet memory test, use the show diagnostic result module test 3 command. The output indicates whether the test passed, failed, or was not run.
show diagnostic result module N test 3 [detail]
Syntax Description
N |
Module number. |
detail |
(Optional) Specifies the display of detailed information for analysis. |
Defaults
Non-detailed results
Command Modes
EXEC mode
Command History
|
|
12.2(18)EW |
This command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The detail keyword is intended for use by Cisco support personnel when analyzing failures.
Examples
This example shows how to display the results from the ongoing packet memory tests:
Switch# show diagnostic result module 1 test 3
Test results: (. = Pass, F = Fail, U = Untested)
3) packet-memory-ongoing -----------> .
This example shows how to display the detailed results from the ongoing packet memory tests:
Switch# show diagnostic result module 1 test 3 detail
Test results: (. = Pass, F = Fail, U = Untested)
___________________________________________________________________________
3) packet-memory-ongoing -----------> .
Error code ------------------> 0 (DIAG_SUCCESS)
Total run count -------------> 0
Last test execution time ----> n/a
First test failure time -----> n/a
Last test failure time ------> n/a
Last test pass time ---------> n/a
Total failure count ---------> 0
Consecutive failure count ---> 0
packet buffers on free list: 64557 bad: 0 used for ongoing tests: 979
Packet memory errors: 0 0
Current alert level: green
Per 5 seconds in the last minute:
Per minute in the last hour:
Per hour in the last day:
Per day in the last 30 days:
Direct memory test failures per minute in the last hour:
Potential false positives: 0 0
Ignored because of rx errors: 0 0
Ignored because of cdm fifo overrun: 0 0
Ignored because of oir: 0 0
Ignored because isl frames received: 0 0
Ignored after writing hw stats: 0 0
Ignored on high gigaport: 0
Ongoing diag action mode: Normal
Last 1000 Memory Test Failures: v
Last 1000 Packet Memory errors:
First 1000 Packet Memory errors:
Related Commands
diagnostic monitor action
show diagnostic result module test 2
show dot1x
To display the 802.1X statistics and operational status for the entire switch or for a specified interface, use the show dot1x command.
show dot1x [interface interface-id] | [statistics [interface interface-id]] | [all]
Syntax Description
interface interface-id |
(Optional) Displays the 802.1X status for the specified port. |
statistics |
(Optional) Displays 802.1X statistics for the switch or the specified interface. |
all |
(Optional) Displays per-interface 802.1X configuration information for all interfaces with a non-default 802.1X configuration. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(12c)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Display enhanced to show the guest-VLAN value. |
12.2(25)EW |
Support for the 10-Gigabit Ethernet interface was introduced on the Catalyst 4500 series switch. |
12.2(25)EWA |
Support for currently-assigned reauthentication timer (if the timer is configured to honor the Session-Timeout value) was added. |
Usage Guidelines
If you do not specify an interface, the global parameters and a summary are displayed. If you specify an interface, the details for that interface are displayed.
If you specify the statistics keyword without the interface option, the statistics are displayed for all interfaces. If you specify the statistics keyword with the interface option, the statistics are displayed for the specified interface.
Expressions are case sensitive. For example, if you enter exclude output, the lines that contain output are not displayed, but the lines that contain Output are displayed.
The show dot1x command displays the currently-assigned reauthentication timer and time remaining before reauthentication, if reauthentication is enabled.
Examples
This example shows how to display the output from the show dot1x command:
Sysauthcontrol = Disabled
Dot1x Protocol Version = 1
Dot1x Oper Controlled Directions = Both
Dot1x Admin Controlled Directions = Both
This example shows how to display the 802.1X statistics for a specific port:
Switch# show dot1x interface fa6/1
Supplicant MAC <Not Applicable>
ReAuthPeriod = 3600 Seconds (Locally Configured)
ReAuthAction = Reauthenticate
Re-authentication = Enabled
ReAuthPeriod = 3600 Seconds
ServerTimeout = 30 Seconds
Note
Table 2-16 provides a partial list of the displayed fields. The remaining fields in the display show internal state information. For a detailed description of these state machines and their settings, refer to the 802.1X specification.
Table 2-16 show dot1x interface Field Description
|
|
PortStatus |
Status of the port (authorized or unauthorized). The status of a port is displayed as authorized if the dot1x port-control interface configuration command is set to auto and has successfully completed authentication. |
Port Control |
Setting of the dot1x port-control interface configuration command. |
MultiHosts |
Setting of the dot1x multiple-hosts interface configuration command (allowed or disallowed). |
This is an example of output from the show dot1x statistics interface gigabitethernet1/1 command. Table 2-17 describes the fields in the display.
Switch# show dot1x statistics interface gigabitethernet1/1
PortStatistics Parameters for Dot1x
--------------------------------------------
TxReqId = 0 TxReq = 0 TxTotal = 0
RxStart = 0 RxLogoff = 0 RxRespId = 0 RxResp = 0
RxInvalid = 0 RxLenErr = 0 RxTotal= 0
RxVersion = 0 LastRxSrcMac 0000.0000.0000
Table 2-17 show dot1x statistics Field Descriptions
|
|
TxReq/TxReqId |
Number of EAP-request/identity frames that have been sent. |
TxTotal |
Number of EAPOL frames of any type that have been sent. |
RxStart |
Number of valid EAPOL-start frames that have been received. |
RxLogoff |
Number of EAPOL-logoff frames that have been received. |
RxRespId |
Number of EAP-response/identity frames that have been received. |
RxResp |
Number of valid EAP-response frames (other than response/identity frames) that have been received. |
RxInvalid |
Number of EAPOL frames that have been received and have an unrecognized frame type. |
RxLenError |
Number of EAPOL frames that have been received in which the packet body length field is invalid. |
RxTotal |
Number of valid EAPOL frames of any type that have been received. |
RxVersion |
Protocol version number carried in the most recently received EAPOL frame. |
LastRxSrcMac |
Source MAC address carried in the most recently received EAPOL frame. |
Related Commands
dot1x guest-vlan
dot1x max-reauth-req
dot1x port-control
show environment
To display the environment alarm, operational status, and current reading for the chassis, use the show environment command.
show environment [alarm] | [status [chassis | fantray | powersupply | supervisor]] | [temperature]
Syntax Description
alarm |
(Optional) Specifies the alarm status of the chassis. |
status |
(Optional) Specifies the operational status information. |
chassis |
(Optional) Specifies the operational status of the chassis. |
fantray |
(Optional) Specifies the status of the fan tray, and shows fan tray power consumption. |
powersupply |
(Optional) Specifies the status of the power supply. |
supervisor |
(Optional) Specifies the status of the supervisor engine. |
temperature |
(Optional) Specifies the current chassis temperature readings. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Support for the ability to display generic environment information with the show environment command was added. |
Examples
This example shows how to display information about the environment alarms, operational status, and current temperature readings for the chassis:
Chassis Temperature = 32 degrees Celsius
Chassis Over Temperature Threshold = 75 degrees Celsius
Chassis Critical Temperature Threshold = 95 degrees Celsius
Supply Model No Type Status Sensor
------ --------------- --------- ----------- ------
PS1 PWR-C45-1400AC AC 1400W good good
Power Supply Max Min Max Min Absolute
(Nos in Watts) Inline Inline System System Maximum
-------------- ------ ------ ------ ------ --------
Power supplies needed by system : 1
Supervisor Led Color : Green
Power consumed by Fantray : 50 Watts
This example shows how to display information about the environment alarms:
Switch#
show environment alarm
This example shows how to display information about the power supplies, chassis type, and fan trays:
Switch#
show environment status
Supply Model No Type Status Sensor
------ --------------- --------- ----------- ------
PS1 PWR-C45-1400AC AC 1400W good good
Power Supply Max Min Max Min Absolute
(Nos in Watts) Inline Inline System System Maximum
-------------- ------ ------ ------ ------ --------
Power supplies needed by system : 1
Supervisor Led Color : Green
Power consumed by Fantray : 50 Watts
This example shows how to display information about the chassis:
Switch# show environment status chassis
This example shows how to display information about the fan tray:
Switch# show environment status fantray
Power consumed by Fantray : 50 Watts
This example shows how to display information about the power supply:
Switch# show environment status powersupply
Supply Model No Type Status Sensor
------ --------------- --------- ------- ------
PS1 WS-X4008 AC 400W good good
PS2 WS-X4008 AC 400W good good
This example shows how to display information about the supervisor engine:
Switch# show environment status supervisor
Supervisor Led Color :Green
This example shows how to display information about the temperature of the chassis:
Switch#
show environment temperature
Chassis Temperature = 32 degrees Celsius
Chassis Over Temperature Threshold = 75 degrees Celsius
Chassis Critical Temperature Threshold = 95 degrees Celsius
show errdisable detect
To display the error disable detection status, use the show errdisable detect command.
show errdisable detect
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Display includes the status of storm control. |
Examples
This example shows how to display the error disable detection status:
Switch#
show errdisable detect
ErrDisable Reason Detection status
----------------- ----------------
security-violatio Enabled
channel-misconfig Disabled
psecure-violation Enabled
Related Commands
errdisable detect
errdisable recovery
show interfaces status
show errdisable recovery
To display error disable recovery timer information, use the show errdisable recovery command.
show errdisable recovery
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Display includes the status of storm control. |
Examples
This example shows how to display recovery timer information for error disable:
Switch# show errdisable recovery
ErrDisable Reason Timer Status
----------------- --------------
security-violatio Disabled
channel-misconfig Disabled
psecure-violation Disabled
Timer interval:30 seconds
Interfaces that will be enabled at the next timeout:
Interface Errdisable reason Time left(sec)
--------- ----------------- --------------
Related Commands
errdisable detect
errdisable recovery
show interfaces status
show etherchannel
To display EtherChannel information for a channel, use the show etherchannel command.
show etherchannel [channel-group] {port-channel | brief | detail | summary | port | load-balance | protocol}
Syntax Description
channel-group |
(Optional) Number of the channel group; valid values are from 1 to 64. |
port-channel |
Displays port-channel information. |
brief |
Displays a summary of EtherChannel information. |
detail |
Displays detailed EtherChannel information. |
summary |
Displays a one-line summary per channel group. |
port |
Displays EtherChannel port information. |
load-balance |
Displays load-balance information. |
protocol |
Displays the enabled protocol. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(13)EW |
Support for LACP was added to this command. |
Usage Guidelines
If you do not specify a channel group, all channel groups are displayed.
In the output below, the Passive port list field is displayed for Layer 3 port channels only. This field means that the physical interface, which is still not up, is configured to be in the channel group (and indirectly is in the only port channel in the channel group).
Examples
This example shows how to display port-channel information for a specific group:
Switch#
show etherchannel 1 port-channel
Port-channels in the group:
Age of the Port-channel = 02h:35m:26s
Logical slot/port = 10/1 Number of ports in agport = 0
GC = 0x00000000 HotStandBy port = null
Passive port list = Fa5/4 Fa5/5
Port state = Port-channel L3-Ag Ag-Not-Inuse
Ports in the Port-channel:
This example shows how to display load-balancing information:
Switch#
show etherchannel load-balance
Source XOR Destination mac address
This example shows how to display a summary of information for a specific group:
Switch#
show etherchannel 1 brief
port-channels: 1 Max port-channels = 1
This example shows how to display detailed information for a specific group:
Switch#
show etherchannel 1 detail
Port-channels: 1 Max Port-channels = 1
Port state = EC-Enbld Down Not-in-Bndl Usr-Config
Channel group = 1 Mode = Desirable Gcchange = 0
Port-channel = null GC = 0x00000000 Psudo-agport = Po1
Port indx = 0 Load = 0x00
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
Hello Partner PAgP Learning Group
Port Flags State Timers Interval Count Priority Method Ifindex
Fa5/4 d U1/S1 1s 0 128 Any 0
Age of the port in the current state: 02h:33m:14s
Port state = EC-Enbld Down Not-in-Bndl Usr-Config
Channel group = 1 Mode = Desirable Gcchange = 0
Port-channel = null GC = 0x00000000 Psudo-agport = Po1
Port indx = 0 Load = 0x00
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
Hello Partner PAgP Learning Group
Port Flags State Timers Interval Count Priority Method Ifindex
Fa5/5 d U1/S1 1s 0 128 Any 0
Age of the port in the current state: 02h:33m:17s
Port-channels in the group:
Age of the Port-channel = 02h:33m:52s
Logical slot/port = 10/1 Number of ports in agport = 0
GC = 0x00000000 HotStandBy port = null
Passive port list = Fa5/4 Fa5/5
Port state = Port-channel L3-Ag Ag-Not-Inuse
Ports in the Port-channel:
This example shows how to display a one-line summary per channel group:
Switch# show etherchannel summary
U-in use I-in port-channel S-suspended D-down i-stand-alone d-default
----- ------------ ----------------------------------------------------------
1 Po1(U) Fa5/4(I) Fa5/5(I)
2 Po2(U) Fa5/6(I) Fa5/7(I)
This example shows how to display EtherChannel port information for all ports and all groups:
Switch#
show etherchannel port
Port state = EC-Enbld Down Not-in-Bndl Usr-Config
Channel group = 1 Mode = Desirable Gcchange = 0
Port-channel = null GC = 0x00000000 Psudo-agport = Po1
Port indx = 0 Load = 0x00
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
Hello Partner PAgP Learning Group
Port Flags State Timers Interval Count Priority Method Ifindex
Fa5/4 d U1/S1 1s 0 128 Any 0
Age of the port in the current state: 02h:40m:35s
Port state = EC-Enbld Down Not-in-Bndl Usr-Config
Channel group = 1 Mode = Desirable Gcchange = 0
Port-channel = null GC = 0x00000000 Psudo-agport = Po1
Port indx = 0 Load = 0x00
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
This example shows how to display the protocol enabled:
Switch# show etherchannel protocol
Related Commands
channel-group
interface port-channel
show flowcontrol
To display the per-interface status and statistics related to flow control, use the show flowcontrol command.
show flowcontrol [module slot | interface interface]
Syntax Description
module slot |
(Optional) Limits the display to interfaces on a specific module. |
interface interface |
(Optional) Displays the status on a specific interface. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Support for the 10-Gigabit Ethernet interface was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
Table 2-18 describes the fields in the show flowcontrol command output.
Table 2-18 show flowcontrol Command Output
|
|
Port |
Module and port number. |
Send-Flowcontrol-Admin |
Flow-control administration. Possible settings: on indicates the local port sends flow control to the far end; off indicates the local port does not send flow control to the far end; desired indicates the local end sends flow control to the far end if the far end supports it. |
Send-Flowcontrol-Oper |
Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
Receive-Flowcontrol-Admin |
Flow-control administration. Possible settings: on indicates the local port requires the far end to send flow control; off indicates the local port does not allow the far end to send flow control; desired indicates the local end allows the far end to send flow control. |
Receive-Flowcontrol-Oper |
Flow-control operation. Possible setting: disagree indicates the two ports could not agree on a link protocol. |
RxPause |
Number of pause frames received. |
TxPause |
Number of pause frames transmitted. |
Examples
This example shows how to display the flow control status on all the Gigabit Ethernet interfaces:
Port Send FlowControl Receive FlowControl RxPause TxPause
--------- -------- -------- -------- -------- ------- -------
Gi1/3 off off desired on 0 0
Gi1/4 off off desired on 0 0
Gi1/5 off off desired on 0 0
Gi1/6 off off desired on 0 0
Gi3/1 off off desired off 0 0
Gi3/2 off off desired off 0 0
Gi3/3 off off desired off 0 0
Gi3/4 off off desired off 0 0
Gi3/5 off off desired off 0 0
Gi3/6 off off desired off 0 0
This example shows how to display the flow control status on module 1:
Switch# show flowcontrol module 1
Port Send FlowControl Receive FlowControl RxPause TxPause
----- -------- -------- -------- -------- ------- -------
Gi1/1 desired off off off 0 0
Gi1/2 on disagree on on 0 0
This example shows how to display the flow control status on Gigabit Ethernet interface 3/4:
Switch# show flowcontrol interface gigabitethernet3/4
Port Send FlowControl Receive FlowControl RxPause TxPause
----- -------- -------- -------- -------- ------- -------
This example shows how to display the flow control status on 10-Gigabit Ethernet interface 1/1:
Switch# show flowcontrol interface tengigabitethernet1/1
Port Send FlowControl Receive FlowControl RxPause TxPause
--------- -------- -------- -------- -------- ------- -------
Related Commands
flowcontrol
show interfaces status
show hw-module uplink
To display the current uplink mode, use the show hw-module uplink command.
show hw-module uplink
Defaults
None
Command Modes
Privileged EXEC
Command History
|
|
12.2(25)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
If the active uplink mode is different than configured mode, the output displays the change.
By default, the current (operational) uplink selection is displayed.
Examples
This example shows the output displaying the current (active) uplinks:
Switch# show hw-module uplink
Active uplink configuration is TenGigabitEthernet
This example shows the output for redundant systems in SSO mode if the 10-Gigabit Ethernet uplinks are active, and the Gigabit Ethernet uplinks are selected:
Switch# show hw-module uplink
Active uplink configuration is TenGigabitEthernet
(will be GigabitEthernet after next reload)
A 'redundancy reload shelf' or power-cycle of chassis is required to
apply the new configuration
This example shows the output for redundant systems in RPR mode if the 10-Gigabit Ethernet uplinks are active, and the Gigabit Ethernet uplinks are selected:
Switch# show hw-module uplink
Active uplink configuration is TenGigabitEthernet
(will be GigabitEthernet after next reload)
A reload of active supervisor is required to apply the new configuration.
Related Commands
hw-module uplink select
show idprom
To display the IDPROMs for the chassis, supervisor engine, module, power supplies, fan trays, clock module, and multiplexer (mux) buffer, use the show idprom command.
show idprom {all | chassis | module [mod] | interface int_name | supervisor | power-supply number | fan-tray}
Syntax Description
all |
Displays information for all IDPROMs. |
chassis |
Displays information for the chassis IDPROMs. |
module |
Displays information for the module IDPROMs. |
mod |
(Optional) Specifies the module name. |
interface int_name |
Displays information for the GBIC or SFP IDPROMs. |
supervisor |
Displays information for the supervisor engine IDPROMs. |
power-supply number |
Displays information for the power supply IDPROMs. |
fan-tray |
Displays information for the fan tray IDPROMs. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Support for the power-supply, fan-tray, clock-module, and mux-buffer keywords was added. |
12.1(13)EW |
Support for interface keyword was added. |
12.2(18)EW |
Enhanced the show idprom interface output to include the hexadecimal display of the GBIC/SFP SEEPROM contents. |
12.2(25)EW |
Support for the 10-Gigabit Ethernet interface was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
When you enter the show idprom interface command, the output lines for Calibration type and Rx (receive) power measurement may not be displayed for all GBICs.
Examples
This example shows how to display IDPROM information for module 4:
Switch#
show idprom module 4
Common Block Signature = 0xABAB
Common Block Length = 144
Common Block Checksum = 4199
OEM String = Cisco Systems, Inc.
Product Number = WS-X4306
Manufacturing Bits = 0x0000
Engineering Bits = 0x0000
Snmp OID = 0.0.0.0.0.0.0.0
RMA Failure Code = 0 0 0 0
Linecard Block Signature = 0x4201
Linecard Block Version = 1
Linecard Block Length = 24
Linecard Block Checksum = 658
Feature Bits = 0x0000000000000000
MAC Base = 0010.7bab.9830
This example shows how to display IDPROM information for the GBICs on the Gigabit Ethernet interface 1/2:
Switch#
show idprom interface gigabitethernet1/2
GBIC Serial EEPROM Contents:
Extended Id = Not specified/compliant with defined MOD_DEF [0x0]
Connector = SC connector [0x1]
Speed = Not available [0x0]
Media = Not available [0x0]
Technology = Not available [0x0]
Link Length = Not available [0x0]
GE Comp Codes = Not available [0x0]
SONET Comp Codes = Not available [0x0]
BR, Nominal = 1300000000 MHz
Length(9u) in km = GBIC does not support single mode fibre, or the length
must be determined from the transceiver technology.
Length(50u) = GBIC does not support 50 micron multi-mode fibre, or the
length must be determined from the transceiver technology.
Length(62.5u) = GBIC does not support 62.5 micron multi-mode fibre, or
the length must be determined from transceiver technology.
Length(Copper) = GBIC does not support copper cables, or the length must
be determined from the transceiver technology.
Vendor name = CISCO-FINISAR
Vendor Part No. = FTR-0119-CSC
Wavelength = Not available
Options = Loss of Signal implemented TX_FAULT signal implemented TX_DISABLE is
implemented and disables the serial output [0x1A]
Vendor Serial No. = K1273DH
Diag monitoring = Implemented
Calibration type = Internal
Rx pwr measuremnt = Optical Modulation Amplitude (OMA)
Address change = Required
Vendor Specific ID Fields:
20944D30 29 00 02 80 22 33 38 3D C7 67 83 E8 DF 65 6A AF )..."38=Gg^Ch_ej/
20944D40 1A 80 ED 00 00 00 00 00 00 00 00 00 38 23 3C 1B ............8#<.
SEEPROM contents (hex) size 128:
0x0000 01 00 01 00 00 00 00 00 00 00 00 01 0D 00 00 FF ................
0x0010 00 00 00 00 43 49 53 43 4F 2D 46 49 4E 49 53 41 ....CISCO-FINISA
0x0020 52 20 20 20 00 00 90 65 46 54 52 2D 30 31 31 39 R ..^PeFTR-0119
0x0030 2D 43 53 43 20 20 20 20 42 20 20 20 00 00 00 1A -CSC B ....
0x0040 00 1A 00 00 4B 31 32 37 33 44 48 20 20 20 20 20 ....K1273DH
0x0050 20 20 20 20 30 33 30 34 30 39 20 20 64 00 00 B2 030409 d..2
0x0060 29 00 02 80 22 33 38 3D C7 67 83 E8 DF 65 6A AF )..^@"38=Gg^C._ej.
0x0070 1A 80 ED 00 00 00 00 00 00 00 00 00 38 23 3C 1B .^@m.........8#<.
This example shows how to display IDPROM information for the 10-Gigabit Ethernet interface 1/1:
Switch#
show idprom interface tengigabitethernet1/1
X2 Serial EEPROM Contents:
Non-Volatile Register (NVR) Fields
X2 MSA Version supported :0xA
Number of bytes used :0xD0
Customer Field Address :0x77
Vendor Field Address :0xA7
Extended Vendor Field Address :0x100
Transceiver type :0x2 =X2
Optical connector type :0x1 =SC
Normal BitRate in multiple of 1M b/s :0x2848
Protocol Type :0x1 =10GgE
Standards Compliance Codes :
10GbE Code Byte 0 :0x2 =10GBASE-LR
SONET/SDH Code Byte 0 :0x0
SONET/SDH Code Byte 1 :0x0
SONET/SDH Code Byte 2 :0x0
SONET/SDH Code Byte 3 :0x0
Transmission range in 10m :0x3E8
Fibre Type Byte 0 :0x40 =NDSF only
Fibre Type Byte 1 :0x0 =Unspecified
Centre Optical Wavelength in 0.01nm steps - Channel 0 :0x1 0xFF 0xB8
Centre Optical Wavelength in 0.01nm steps - Channel 1 :0x0 0x0 0x0
Centre Optical Wavelength in 0.01nm steps - Channel 2 :0x0 0x0 0x0
Centre Optical Wavelength in 0.01nm steps - Channel 3 :0x0 0x0 0x0
Package Identifier OUI :0xC09820
Transceiver Vendor OUI :0x3400800
Transceiver vendor name :CISCO-OPNEXT,INC
Part number provided by transceiver vendor :TRT5021EN-SMC-W
Revision level of part number provided by vendor :00
Vendor serial number :ONJ08290041
Vendor manufacturing date code :2004072000
Reserved1 : 00 02 02 20 D1 00 00
Basic Field Checksum :0x10
0x00: 58 32 2D 31 30 47 42 2D 4C 52 20 20 20 20 20 20
0x10: 20 20 20 20 20 4F 4E 4A 30 38 32 39 30 30 34 31
0x20: 31 30 2D 32 30 33 36 2D 30 31 20 20 41 30 31 20
0x00: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x10: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x20: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
0x30: 00 00 00 00 11 E2 69 A9 2F 95 C6 EE D2 DA B3 FD
0x40: 9A 34 4A 24 CB 00 00 00 00 00 00 00 00 00 EF FC
0x50: F4 AC 1A D7 11 08 01 36 00
This example shows how to display IDPROM information for the supervisor engine:
Switch#
show idprom supervisor
Common Block Signature = 0xABAB
Common Block Length = 144
Common Block Checksum = 4153
OEM String = Cisco Systems, Inc.
Product Number = WS-X4014
Serial Number = JAB05320CCE
Manufacturing Deviation String = 0
Manufacturing Bits = 0x0000
Engineering Bits = 0x0000
Snmp OID = 0.0.0.0.0.0.0.0
RMA Failure Code = 0 0 0 0
Supervisor Block Signature = 0x4101
Supervisor Block Version = 1
Supervisor Block Length = 24
Supervisor Block Checksum = 548
Feature Bits = 0x0000000000000000
MAC Base = 0007.0ee5.2a44
This example shows how to display IDPROM information for the chassis:
Switch#
show idprom chassis
Common Block Signature = 0xABAB
Common Block Length = 144
Common Block Checksum = 4285
OEM String = Cisco Systems, Inc.
Product Number = WS-C4006
Serial Number = FOX04473737
Manufacturing Deviation String = 0x00
Manufacturing Bits = 0x0000
Engineering Bits = 0x0000
Snmp OID = 0.0.0.0.0.0.0.0
Chassis Block Signature = 0x4001
Chassis Block Version = 1
Chassis Block Length = 22
Chassis Block Checksum = 421
Feature Bits = 0x0000000000000000
MAC Base = 0004.dd42.2600
This example shows how to display IDPROM information for power supply 1:
Switch#
show idprom power-supply 1
Common Block Signature = 0xABAB
Common Block Length = 144
Common Block Checksum = 10207
OEM String = Cisco Systems, Inc.
Product Number = WS-CAC-1440W
Serial Number = ACP05180002
Manufacturing Deviation String =
Manufacturing Bits = 0x0000
Engineering Bits = 0x3031
Snmp OID = 9.12.3.65535.65535.65535.65535.65535
RMA Failure Code = 255 255 255 255
Power Supply Block Signature = 0xFFFF
PowerSupply Block Version = 255
PowerSupply Block Length = 255
PowerSupply Block Checksum = 65535
Feature Bits = 0x00000000FFFFFFFF
This example shows how to display IDPROM information for the fan tray:
Switch#
show idprom fan-tray
Common Block Signature = 0xABAB
Common Block Length = 144
Common Block Checksum = 19781
OEM String = "Cisco Systems"
Product Number = WS-X4502-fan
Manufacturing Deviation String =
Manufacturing Bits = 0xFFFF
Engineering Bits = 0xFFFF
Snmp OID = 65535.65535.65535.65535.65535.65535.65535.65535
RMA Failure Code = 255 255 255 255
show interfaces
To display traffic on a specific interface, use the show interfaces command.
show interfaces [{{fastethernet mod/interface-number} | {gigabitethernet mod/interface-number} | {tengigabitethernet mod/interface-number} | {null interface-number} | vlan vlan_id} | status}]
Syntax Description
fastethernet mod/interface-number |
(Optional) Specifies the Fast Ethernet module and interface. |
gigabitethernet mod/interface-number |
(Optional) Specifies the Gigabit Ethernet module and interface. |
tengigabitethernet mod/interface-number |
(Optional) Specifies the 10-Gigabit Ethernet module and interface. |
null interface-number |
(Optional) Specifies the null interface; the valid value is 0. |
vlan vlan_id |
(Optional) Specifies the VLAN; valid values are from 1 to 4094. |
status |
(Optional) Displays status information. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Support for extended VLAN addresses was added. |
12.2(25)EW |
Support for the 10-Gigabit Ethernet interface was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The statistics are collected on a per-VLAN basis for Layer 2-switched packets and Layer 3-switched packets. The statistics are available for both unicast and multicast. The Layer 3-switched packet counts are available for both the ingress and egress directions. The per-VLAN statistics are updated every 5 seconds.
In some cases, you might see a difference in the duplex mode that is displayed between the
show interfaces command and the show running-config commands. The duplex mode that is displayed in the show interfaces command is the actual duplex mode that the interface is running. The
show interfaces command shows the operating mode for an interface, while the show running-config command shows the configured mode for an interface.
If you do not enter any keywords, all counters for all modules are displayed.
Examples
This example shows how to display traffic for a Gigabit Ethernet interface 2/5:
Switch# show interfaces gigabitethernet2/5
GigabitEthernet9/5 is up, line protocol is up
Hardware is C4k 1000Mb 802.3, address is 0001.64f8.3fa5 (bia 0001.64f8.3fa5)
Internet address is 172.20.20.20/24
MTU 1500 bytes, BW 1000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:00, output never, output hang never
Last clearing of "show interface" counters never
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 1000 bits/sec, 2 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
L2 Switched: ucast: 8199 pkt, 1362060 bytes - mcast: 6980 pkt, 371952 bytes
L3 in Switched: ucast: 0 pkt, 0 bytes - mcast: 0 pkt, 0 bytes mcast
L3 out Switched: ucast: 0 pkt, 0 bytes - mcast: 0 pkt, 0 bytes
300114 packets input, 27301436 bytes, 0 no buffer
Received 43458 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 input packets with dribble condition detected
15181 packets output, 1955836 bytes, 0 underruns
0 output errors, 0 collisions, 3 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
This example shows how to display traffic for a 10-Gigabit Ethernet interface 1/1:
Switch# show interfaces tengigabitethernet1/1
TenGigabitEthernet1/1 is up, line protocol is up (connected)
Hardware is Ten Gigabit Ethernet Port, address is 0004.dd46.7700 (bia 0004.dd46.7700)
MTU 1500 bytes, BW 10000000 Kbit, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Full-duplex, 10Gb/s, link type is auto, media type is 10GBaseL
input flow-control is off, output flow-control is off
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 multicast)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
This example shows how to display status information for Gigabit Ethernet interface 1/2:
Switch# show interfaces gigabitethernet1/2 status
Port Name Status Vlan Duplex Speed Type
Gi1/2 notconnect 1 auto 1000 1000-XWDM-RXONLY
This example shows how to display status information for the interfaces on the supervisor engine:
Switch# show interfaces status
Port Name Status Vlan Duplex Speed Type
Te1/1 connected 1 full 10G 10GBase-LR
Te1/2 connected 1 full 10G 10GBase-LR
show interfaces capabilities
To display the interface capabilities for an interface or for all the interfaces on a switch, use the
show interfaces capabilities command.
show interfaces capabilities [{module mod}]
show interfaces [interface interface-number] capabilities
Syntax Description
module mod |
(Optional) Display information for the specified module only. |
interface |
(Optional) Interface type; valid values are fastethernet, gigabitethernet, tengigabitethernet, and port-channel. |
interface-number |
(Optional) Port number. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Support for the 10-Gigabit Ethernet interface was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The interface-number argument designates the module and port number. Valid values for interface-number depend on the chassis and module used. For example, if you have a 48-port 10/100-Mbps Fast Ethernet RJ-21 (telco connector) switching module installed in a Catalyst 4507 chassis, valid values for the slot number are from 2 to 13 and valid values for the port number are 1 to 48.
Examples
This example shows how to display the interface capabilities for a module:
Switch# show interfaces capabilities module 1
Trunk encap. type: 802.1Q,ISL
Trunk mode: on,off,desirable,nonegotiate
Broadcast suppression:percentage(0-100), hw
Flowcontrol: rx-(off,on,desired),tx-(off,on,desired)
VLAN Membership: static, dynamic
Queuing: rx-(N/A), tx-(4q1t, Sharing/Shaping)
Trunk encap. type: 802.1Q,ISL
Trunk mode: on,off,desirable,nonegotiate
Broadcast suppression:percentage(0-100), hw
Flowcontrol: rx-(off,on,desired),tx-(off,on,desired)
VLAN Membership: static, dynamic
Queuing: rx-(N/A), tx-(4q1t, Sharing/Shaping)
This example shows how to display the interface capabilities for the 10-Gigabit Ethernet interface 1/1:
Switch# show interfaces tengigabitethernet1/1 capabilities
Trunk encap. type: 802.1Q,ISL
Trunk mode: on,off,desirable,nonegotiate
Broadcast suppression: percentage(0-100), hw
Flowcontrol: rx-(off,on),tx-(off,on)
VLAN Membership: static, dynamic
Queuing: rx-(N/A), tx-(1p3q1t, Sharing/Shaping)
Maximum MTU: 9198 bytes (Jumbo Frames)
Diagnostic Monitoring: N/A
This example shows how to display the interface capabilities for Gigabit Ethernet interface 1/1:
Switch# show interfaces gigabitethernet1/1 capabilities
Trunk encap. type: 802.1Q,ISL
Trunk mode: on,off,desirable,nonegotiate
Broadcast suppression:percentage(0-100), hw
Flowcontrol: rx-(off,on,desired),tx-(off,on,desired)
VLAN Membership: static, dynamic
Queuing: rx-(N/A), tx-(4q1t, Sharing/Shaping)
MTU Supported: jumbo frames, baby giants
This example shows how to display the interface capabilities for Fast Ethernet interface 3/1:
Switch# show interfaces fastethernet3/1 capabilities
Trunk encap. type: 802.1Q,ISL
Trunk mode: on,off,desirable,nonegotiate
Broadcast suppression:percentage(0-100), sw
Flowcontrol: rx-(none),tx-(none)
VLAN Membership: static, dynamic
Queuing: rx-(N/A), tx-(4q1t, Shaping)
MTU Supported: no jumbo frames, baby giants
Related Commands
show interfaces counters
show interfaces counters
To display the traffic on the physical interface, use the show interfaces counters command.
show interfaces counters [all | detail | errors | storm-control | trunk] [module mod]
Syntax Description
all |
(Optional) Displays all the interface counters including errors, trunk, and detail. |
detail |
(Optional) Displays the detailed interface counters. |
errors |
(Optional) Displays the interface error counters. |
storm-control |
(Optional) Displays the number of packets discarded due to suppression on the interface. |
trunk |
(Optional) Displays the interface trunk counters. |
module mod |
(Optional) Limits the display to interfaces on a specific module. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Support for storm control. |
12.2(18)EW |
Support for the display of total suppression discards. |
Usage Guidelines
If you do not enter any keywords, all the counters for all modules are displayed.
The display for the storm-control keyword includes the suppressed multicast bytes.
Examples
This example shows how to display the error counters for a specific module:
Switch#
show interfaces counters errors module 1
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
Port Single-Col Multi-Col Late-Col Excess-Col Carri-Sen Runts Giants
This example shows how to display the traffic that is seen by a specific module:
Switch#
show interfaces counters module 1
Port InOctets InUcastPkts InMcastPkts InBcastPkts
Port OutOctets OutUcastPkts OutMcastPkts OutBcastPkts
This example shows how to display the trunk counters for a specific module:
Switch#
show interfaces counters trunk module 1
Port TrunkFramesTx TrunkFramesRx WrongEncap
This example shows how to display the number of packets that are discarded due to suppression:
Switch#
show interfaces counters storm-control
Multicast Suppression : Enabled
Port BcastSuppLevel TotalSuppressionDiscards
Related Commands
show interfaces capabilities
show interfaces description
To display a description and status of an interface, use the show interfaces description command.
show interfaces [interface] description
Syntax Description
interface |
(Optional) Type of interface. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display information for all interfaces:
Switch# show interfaces description
Interface Status Protocol Description
PO0/0 admin down down First interface
Gi1/1 up up GigE to server farm
Related Commands
description (refer to Cisco IOS documentation)
show interfaces link
To display how long a cable has been disconnected from an interface, use the show interfaces link command:
show interfaces link [module mod_num]
Syntax Description
module mod_num |
(Optional) Limits the display to interfaces on a module. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.2(18)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
If the interface state is up, the command displays 0:00. If the interface state is down, the time (in hours, minutes, and seconds) is displayed.
Examples
This example shows how to display active link-level information:
Switch# show interfaces link
This example shows how to display inactive link-level information:
Switch# show interfaces link
In this example, the cable has been disconnected from the port for 1 minute and 28 seconds.
show interfaces mtu
To display the maximum transmission unit (MTU) size of all the physical interfaces and SVIs on the switch, use the show interfaces mtu command.
show interfaces mtu [module mod]
Syntax Description
module mod |
(Optional) Limits the display to interfaces on a specific module. |
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.1(13)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the MTU size for all interfaces on module 1:
Switch>
show interfaces mtu module 1
Related Commands
mtu
show interfaces private-vlan mapping
To display PVLAN mapping information for VLAN SVIs, use the show interfaces private-vlan mapping command.
show interfaces private-vlan mapping [active]
Syntax Description
active |
(Optional) Displays active interfaces only. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
This command displays SVI information only.
Examples
This example shows how to display PVLAN mapping information:
Switch# show interfaces private-vlan mapping
Interface Secondary VLAN Type
--------- -------------- -----------------
Related Commands
private-vlan
private-vlan mapping
show interfaces status
To display the interface status or a list of interfaces in error-disabled state, use the show interfaces status command.
show interfaces status [err-disabled]
Syntax Description
err-disabled |
(Optional) Displays interfaces in error-disabled state. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the status of all interfaces:
Switch#
show interfaces status
Port Name Status Vlan Duplex Speed Type
Gi1/1 disabled routed full 1000 missing
Gi1/2 notconnect 1 full 1000 unknown (4)
Fa5/1 disabled routed auto auto 10/100BaseTX
Fa5/2 disabled routed auto auto 10/100BaseTX
Fa5/3 disabled routed auto auto 10/100BaseTX
Fa5/4 disabled routed auto auto 10/100BaseTX
Fa5/15 disabled routed auto auto 10/100BaseTX
Fa5/16 disabled routed auto auto 10/100BaseTX
Fa5/17 disabled routed auto auto 10/100BaseTX
This example shows how to display the status of interfaces in an error-disabled state:
Switch#
show interfaces status err-disabled
Fa9/4 notconnect link-flap
informational error message when the timer expires on a cause
--------------------------------------------------------------
5d04h:%PM-SP-4-ERR_RECOVER:Attempting to recover from link-flap err-disable state on Fa9/4
Related Commands
errdisable detect
show errdisable recovery
show interfaces switchport
To display the administrative and operational status of a switching (nonrouting) port, use the show interfaces switchport command.
show interfaces [interface-id] switchport [module mod]
Syntax Description
interface-id |
(Optional) Interface ID for the physical port. |
module mod |
(Optional) Limits the display to interfaces on the specified module; valid values are from 1 to 6. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Support for per-interface display. |
12.2(18)EW |
Support for displaying the status of native VLAN tagging in the command output. |
Examples
This example shows how to display switch-port information using the begin output modifier:
Switch#
show interfaces switchport | include VLAN
Access Mode VLAN: 200 (VLAN0200)
Trunking Native Mode VLAN: 1 (default)
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: ALL
This example shows how to display switch-port information for module 1:
Switch#
show interfaces switchport module 1
Administrative Mode:dynamic auto
Administrative Trunking Encapsulation:negotiate
Negotiation of Trunking:On
Access Mode VLAN:1 (default)
Trunking Native Mode VLAN:1 (default)
Administrative private-vlan host-association:none
Administrative private-vlan mapping:none
Operational private-vlan:none
Trunking VLANs Enabled:ALL
Pruning VLANs Enabled:2-1001
Administrative Mode:dynamic auto
Administrative Trunking Encapsulation:negotiate
Negotiation of Trunking:On
Access Mode VLAN:1 (default)
Trunking Native Mode VLAN:1 (default)
Administrative private-vlan host-association:none
Administrative private-vlan mapping:none
Operational private-vlan:none
Trunking VLANs Enabled:ALL
Pruning VLANs Enabled:2-1001
This example shows how to display the status of native VLAN tagging on the port:
Switch#
show interfaces g1/2 switchport
Administrative Mode: dynamic auto
Operational Mode: static access
Administrative Trunking Encapsulation: negotiate
Operational Trunking Encapsulation: native
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Native VLAN tagging: Disabled **
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk private VLANs: none
Administrative private-vlan trunk Native VLAN tagging: Disabled
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture VLANs Allowed: ALL
Unknown unicast blocked: disabled
Unknown multicast blocked: disabled
Related Commands
show interfaces capabilities
show interfaces counters
show interfaces transceiver
To display diagnostic-monitoring data for all interfaces that have transceivers installed, use the show interfaces transceiver command.
show interfaces {{[int_name] transceiver {[detail]} | {transceiver [module mod] | detail [module mod]}}
Syntax Description
int_name |
(Optional) Interface. |
detail |
(Optional) Displays the calibrated values and the A2D readouts if the readout values differ from the calibrated values. Also displays the high-alarm, high-warning, low-warning, and low-alarm thresholds. |
module mod |
(Optional) Limits the display to interfaces on a specific module. |
Defaults
The noninterface-specific versions of the show interfaces transceiver command are enabled by default.
The interface-specific versions of these commands are enabled by default if the specified interface has a transceiver (GBIC or SFP) that is configured for diagnostic monitoring, and the transceiver is in a module that supports diagnostic monitoring.
Command Modes
Privileged EXEC
Command History
|
|
12.1(20)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(18)EW |
Support for the calibration keyword was withdrawn. |
Usage Guidelines
The show interfaces transceiver command provides useful information under the following conditions:
•
At least one transceiver is installed on a chassis that is configured for diagnostic monitoring.
•
The transceiver is in a module that supports diagnostic monitoring.
If you notice that the alarm and warning flags have been set on a transceiver, reenter the command to confirm.
Examples
This example shows how to display diagnostic monitoring data for all interfaces with transceivers installed on the switch:
Switch# show interfaces transceiver
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Gi1/1 48.1 3.30 0.0 8.1 ++ N/A
Gi1/2 33.0 3.30 1.8 -10.0 -36.9
Gi2/1 43.7 5.03 50.6 + -16.7 -- N/A
Gi2/2 39.2 5.02 25.7 0.8 N/A
Note
The value for the Optical Tx Power (in dBm) equals ten times log (Tx Power in mW). If the Tx Power value is 3 mW, then the Optical Tx Power value equals 10 * log (3), which equals 10 * .477 or 4.77 dBm. The Optical Rx Power value behaves similarly. If the Tx Power or the Rx Power is zero, then its dBm value is undefined and is shown as N/A (not applicable).
This example shows how to display detailed diagnostic monitoring data, including calibrated values, alarm and warning thresholds, A2D readouts, and alarm and warning flags. The A2D readouts are reported separately in parentheses only if they differ from the calibrated values:
Switch# show interfaces transceiver detail
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
------- ------------------ ---------- --------- --------- ---------
Gi1/1 48.1 100.0 100.0 0.0 0.0
Gi1/2 34.9 100.0 100.0 0.0 0.0
Gi2/1 43.5 70.0 60.0 5.0 0.0
Gi2/2 39.1 70.0 60.0 5.0 0.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
------- --------------- ---------- --------- --------- ---------
Gi1/1 3.30 6.50 6.50 N/A N/A
Gi1/2 3.30 6.50 6.50 N/A N/A
Gi2/1 5.03 5.50 5.25 4.75 4.50
Gi2/2 5.02 5.50 5.25 4.75 4.50
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
------- ----------------- ---------- --------- --------- ---------
Gi1/1 0.0 130.0 130.0 N/A N/A
Gi1/2 1.7 130.0 130.0 N/A N/A
Gi2/1 50.6 + 60.0 40.0 10.0 5.0
Gi2/2 25.8 60.0 40.0 10.0 5.0
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi1/1 8.1 ++ 8.1 8.1 N/A N/A
Gi1/2 -9.8 8.1 8.1 N/A N/A
Gi2/1 -16.7 (-13.0) -- 3.4 3.2 -0.3 -0.5
Gi2/2 0.8 ( 5.1) 3.4 3.2 -0.3 -0.5
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi1/1 N/A 8.1 8.1 N/A N/A
Gi1/2 -30.9 8.1 8.1 N/A N/A
Gi2/1 N/A (-28.5) 5.9 -6.7 -28.5 -28.5
Gi2/2 N/A (-19.5) 5.9 -6.7 -28.5 -28.5
This example shows how to display the monitoring data for the interfaces that have transceivers installed on module 2:
Switch# show interfaces transceiver module 2
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Gi2/1 43.7 5.03 50.6 + -16.7 -- N/A
Gi2/2 39.2 5.02 25.7 0.8 N/A
This example shows how to display the detailed monitoring data for the interfaces that have transceivers installed on module 2:
Switch# show interfaces transceiver detail module 2
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
------- ------------------ ---------- --------- --------- ---------
Gi2/1 43.5 70.0 60.0 5.0 0.0
Gi2/2 39.1 70.0 60.0 5.0 0.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
------- --------------- ---------- --------- --------- ---------
Gi2/1 5.03 5.50 5.25 4.75 4.50
Gi2/2 5.02 5.50 5.25 4.75 4.50
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 50.6 + 60.0 40.0 10.0 5.0
Gi2/2 25.8 60.0 40.0 10.0 5.0
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 -16.7 (-13.0) -- 3.4 3.2 -0.3 -0.5
Gi2/2 0.8 ( 5.1) 3.4 3.2 -0.3 -0.5
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 N/A (-28.5) 5.9 -6.7 -28.5 -28.5
Gi2/2 N/A (-19.5) 5.9 -6.7 -28.5 -28.5
This example shows how to display the monitoring data for the transceivers on interface Gi1/2:
Switch# show interfaces g1/2 transceiver
ITU Channel 23 (1558.98 nm),
Transceiver is externally calibrated.
If device is externally calibrated, only calibrated values are printed.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
NA or N/A: not applicable, Tx: transmit, Rx: receive.
mA: milliamperes, dBm: decibels (milliwatts).
Temperature Voltage Current Tx Power Rx Power
Port (Celsius) (Volts) (mA) (dBm) (dBm)
------- ----------- ------- -------- -------- --------
Gi2/1 43.7 5.03 50.6 + -16.7 -- N/A
This example shows how to display detailed the monitoring data for the transceivers on interface Gi1/2:
Switch# show interfaces g1/2 transceiver detail
ITU Channel 23 (1558.98 nm),
Transceiver is externally calibrated.
mA: milliamperes, dBm: decibels (milliwatts), NA or N/A: not applicable.
++ : high alarm, + : high warning, - : low warning, -- : low alarm.
A2D readouts (if they differ), are reported in parentheses.
The threshold values are calibrated.
High Alarm High Warn Low Warn Low Alarm
Temperature Threshold Threshold Threshold Threshold
Port (Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
------- ------------------ ---------- --------- --------- ---------
Gi2/1 43.5 70.0 60.0 5.0 0.0
High Alarm High Warn Low Warn Low Alarm
Voltage Threshold Threshold Threshold Threshold
Port (Volts) (Volts) (Volts) (Volts) (Volts)
------- --------------- ---------- --------- --------- ---------
Gi2/1 5.03 5.50 5.25 4.75 4.50
High Alarm High Warn Low Warn Low Alarm
Current Threshold Threshold Threshold Threshold
Port (milliamperes) (mA) (mA) (mA) (mA)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 50.6 + 60.0 40.0 10.0 5.0
Optical High Alarm High Warn Low Warn Low Alarm
Transmit Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 -16.7 (-13.0) -- 3.4 3.2 -0.3 -0.5
Optical High Alarm High Warn Low Warn Low Alarm
Receive Power Threshold Threshold Threshold Threshold
Port (dBm) (dBm) (dBm) (dBm) (dBm)
------- ----------------- ---------- --------- --------- ---------
Gi2/1 N/A (-28.5) 5.9 -6.7 -28.5 -28.5
Related Commands
show idprom
show interfaces status
show interfaces trunk
To display port and module interface-trunk information, use the show interfaces trunk command.
show interfaces trunk [module mod]
Syntax Description
module mod |
(Optional) Limits the display to interfaces on the specified module; valid values are from 1 to 6. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
If you do not specify a keyword, only information for trunking ports is displayed.
Examples
This example shows how to display interface-trunk information for module 5:
Switch#
show interfaces trunk module 5
Port Mode Encapsulation Status Native vlan
Fa5/1 routed negotiate routed 1
Fa5/2 routed negotiate routed 1
Fa5/3 routed negotiate routed 1
Fa5/4 routed negotiate routed 1
Fa5/5 routed negotiate routed 1
Fa5/6 off negotiate not-trunking 10
Fa5/7 off negotiate not-trunking 10
Fa5/8 off negotiate not-trunking 1
Fa5/9 desirable n-isl trunking 1
Fa5/10 desirable negotiate not-trunking 1
Fa5/11 routed negotiate routed 1
Fa5/12 routed negotiate routed 1
Fa5/48 routed negotiate routed 1
Port Vlans allowed on trunk
Port Vlans allowed and active in management domain
Fa5/9 1-6,10,20,50,100,152,200,300,303-305,349-351,400,500,521,524,570,801-8
Port Vlans in spanning tree forwarding state and not pruned
Fa5/9 1-6,10,20,50,100,152,200,300,303-305,349-351,400,500,521,524,570,801-8
This example shows how to display trunking information for active trunking ports:
Switch#
show interfaces trunk
Port Mode Encapsulation Status Native vlan
Fa5/9 desirable n-isl trunking 1
Port Vlans allowed on trunk
Port Vlans allowed and active in management domain
Fa5/9 1-6,10,20,50,100,152,200,300,303-305,349-351,400,500,521,524,570,801-8
Port Vlans in spanning tree forwarding state and not pruned
Fa5/9 1-6,10,20,50,100,152,200,300,303-305,349-351,400,500,521,524,570,801-8
show ip arp inspection
To show the status of dynamic ARP inspection for a specific range of VLANs, use the show ip arp inspection command.
show ip arp inspection {[statistics] vlan vlan-range | interfaces [interface-name]}
Syntax Description
statistics |
(Optional) Displays statistics for the following types of packets that have been processed by this feature: forwarded, dropped, MAC validation failure, and IP validation failure. |
vlan vlan-range |
(Optional) When used with the statistics keyword, displays the statistics for the selected range of VLANs. Without the statistics keyword, displays the configuration and operating state of DAI for the selected range of VLANs. |
interfaces interface-name |
(Optional) Displays the trust state and the rate limit of ARP packets for the provided interface. When the interface name is not specified, the command displays the trust state and rate limit for all applicable interfaces in the system. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the statistics of packets that have been processed by DAI for
VLAN 3:
Switch# show ip arp inspection statistics vlan 3
Vlan Forwarded Dropped DHCP Drops ACL Drops
---- --------- ------- ---------- ----------
Vlan DHCP Permits ACL Permits Source MAC Failures
---- ------------ ----------- -------------------
Vlan Dest MAC Failures IP Validation Failures
---- ----------------- ----------------------
This example shows how to display the statistics of packets that have been processed by DAI for all active VLANs:
Switch# show ip arp inspection statistics
Vlan Forwarded Dropped DHCP Drops ACL Drops
---- --------- ------- ---------- ----------
Vlan DHCP Permits ACL Permits Source MAC Failures
---- ------------ ----------- -------------------
Vlan Dest MAC Failures IP Validation Failures
---- ----------------- ----------------------
This example shows how to display the configuration and operating state of DAI for VLAN 1:
Switch# show ip arp inspection vlan 1
Source Mac Validation : Disabled
Destination Mac Validation : Disabled
IP Address Validation : Disabled
Vlan Configuration Operation ACL Match Static ACL
---- ------------- --------- --------- ----------
Vlan ACL Logging DHCP Logging
---- ----------- ------------
This example shows how to display the trust state of Fast Ethernet interface 6/1:
Switch# show ip arp inspection interfaces fastEthernet 6/1
Interface Trust State Rate (pps) Burst Interval
--------------- ----------- ---------- --------------
This example shows how to display the trust state of the interfaces on the switch:
Switch# show ip arp inspection interfaces
Interface Trust State Rate (pps)
--------------- ----------- ----------
Related Commands
arp access-list
clear ip arp inspection log
show ip arp inspection
show ip arp inspection log
To show the status of the log buffer, use the show ip arp inspection log command.
show ip arp inspection log
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the current contents of the log buffer before and after the buffers are cleared:
Switch# show ip arp inspection log
Total Log Buffer Size : 10
Syslog rate : 0 entries per 10 seconds.
Interface Vlan Sender MAC Sender IP Num of Pkts
--------------- ----- ----------------- --------------- -----------
Fa6/3 1 0002.0002.0002 1.1.1.2 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.3 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.4 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.5 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.6 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.7 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.8 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.9 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.10 1(12:02:52 UTC Fri Apr 25 2003)
Fa6/3 1 0002.0002.0002 1.1.1.11 1(12:02:52 UTC Fri Apr 25 2003)
-- -- -- -- 5(12:02:52 UTC Fri Apr 25 2003)
This example shows how to clear the buffer with the clear ip arp inspection log command:
Switch# clear ip arp inspection log
Switch# show ip arp inspection log
Total Log Buffer Size : 10
Syslog rate : 0 entries per 10 seconds.
No entries in log buffer.
Related Commands
arp access-list
clear ip arp inspection log
show ip cef vlan
To view IP CEF VLAN interface status and configuration information and display the prefixes for a specific interface, use the show ip cef vlan command.
show ip cef vlan vlan_num [detail]
Syntax Description
vlan_num |
Number of the VLAN. |
detail |
(Optional) Displays detailed information. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the prefixes for a specific VLAN:
Switch# show ip cef vlan 1003
Prefix Next Hop Interface
0.0.0.0/0 172.20.52.1 FastEthernet3/3
10.7.0.0/16 172.20.52.1 FastEthernet3/3
10.16.18.0/23 172.20.52.1 FastEthernet3/3
This example shows how to display detailed IP CEF information for a specific VLAN:
Switch# show ip cef vlan 1003 detail
IP Distributed CEF with switching (Table Version 2364), flags=0x0
1383 routes, 0 reresolve, 0 unresolved (0 old, 0 new)
1383 leaves, 201 nodes, 380532 bytes, 2372 inserts, 989 invalidations
0 load sharing elements, 0 bytes, 0 references
universal per-destination load sharing algorithm, id 9B6C9823
3 CEF resets, 0 revisions of existing leaves
refcounts: 54276 leaf, 51712 node
Adjacency Table has 5 adjacencies
show ip dhcp snooping
To display the DHCP snooping configuration, use the show ip dhcp snooping command.
show ip dhcp snooping
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(12c)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EWA |
Support for option 82 on untrusted ports was added. |
Examples
This example shows how to display the DHCP snooping configuration:
Switch# show ip dhcp snooping
Switch DHCP snooping is enabled
DHCP snooping is configured on the following VLANs:
Insertion of option 82 is enabled
Option82 on untrusted port is not allowed
Verification of hwaddr field is enabled
Interface Trusted Rate limit (pps)
-------------------- ------- ----------------
Related Commands
ip dhcp snooping
ip dhcp snooping information option
ip dhcp snooping limit rate
ip dhcp snooping trust
ip dhcp snooping vlan
show ip dhcp snooping binding
To display the DHCP snooping binding entries, use the show ip dhcp snooping binding command.
show ip dhcp snooping binding [ip-address] [mac-address] [vlan vlan_num]
[interface interface_num]
Syntax Description
ip-address |
(Optional) IP address for the binding entries. |
mac-address |
(Optional) MAC address for the binding entries. |
vlan vlan_num |
(Optional) Specifies a VLAN. |
interface interface_num |
(Optional) Specifies an interface. |
Defaults
If no argument is specified, the switch will display the entire DHCP snooping binding table.
Command Modes
Privileged EXEC
Command History
|
|
12.1(12c)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
DHCP snooping is enabled on a VLAN only if both the global snooping and the VLAN snooping are enabled.
To configure a range of VLANs, use the optional last_vlan argument to specify the end of the VLAN range.
Examples
This example shows how to display the DHCP snooping binding entries for a switch:
Switch# show ip dhcp snooping binding
MacAddress IP Address Lease (seconds) Type VLAN Interface
----------- ----------- ---------------- ------------- ----- ------------
0000.0100.0201 10.0.0.1 1600 dhcp-snooping 100 FastEthernet3/1
This example shows how to display an IP address for DHCP snooping binding entries:
Switch# show ip dhcp snooping binding 172.100.101.102
MacAddress IP Address Lease (seconds) Type VLAN Interface
----------- ----------- ---------------- ------------- ----- ------------
0000.0100.0201 172.100.101.102 1600 dhcp-snooping 100 FastEthernet3/1
This example shows how to display the MAC address for the DHCP snooping binding entries:
Switch# show ip dhcp snooping binding 55.5.5.2 0002.b33f.3d5f
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------------- ---- --------------------
00:02:B3:3F:3D:5F 55.5.5.2 492 dhcp-snooping 99 FastEthernet6/36
This example shows how to display the DHCP snooping binding entries' MAC address for a specific VLAN:
Switch# show ip dhcp snooping binding 55.5.5.2 0002.b33f.3d5f vlan 99
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------------- ---- --------------------
00:02:B3:3F:3D:5F 55.5.5.2 479 dhcp-snooping 99 FastEthernet6/36
This example shows how to display the dynamic DHCP snooping binding entries:
Switch# show ip dhcp snooping binding dynamic
MacAddress IP Address Lease (seconds) Type VLAN Interface
----------- ----------- ---------------- ------------ ----- ------------
0000.0100.0201 10.0.0.1 1600 dhcp-snooping 100 FastEthernet3/1
This example shows how to display the DHCP snooping binding entries on VLAN 100:
Switch# show ip dhcp snooping binding vlan 100'
MacAddress IP Address Lease (seconds) Type VLAN Interface
----------- ----------- ---------------- ------------ ----- ------------
0000.0100.0201 10.0.0.1 1600 dhcp-snooping 100 FastEthernet3/1
This example shows how to display the DHCP snooping binding entries on Ethernet interface 0/1:
Switch# show ip dhcp snooping binding interface fastethernet3/1
MacAddress IP Address Lease (seconds) Type VLAN Interface
----------- ----------- ---------------- ------------ ----- ------------
0000.0100.0201 10.0.0.1 1600 dhcp-snooping 100 FastEthernet3/1
Table 2-19 describes the fields in the show ip dhcp snooping command output.
Table 2-19 show ip dhcp snooping Command Output
|
|
Mac Address |
Client hardware MAC address. |
IP Address |
Client IP address assigned from the DHCP server. |
Lease (seconds) |
IP address lease time. |
Type |
Binding type; statically configured from CLI or dynamically learned. |
VLAN |
VLAN number of the client interface. |
Interface |
Interface that connects to the DHCP client host. |
Related Commands
ip dhcp snooping information option
ip dhcp snooping limit rate
ip dhcp snooping trust
ip igmp snooping
ip igmp snooping vlan
show ip dhcp snooping database
To display the status of the DHCP snooping database agent, use the show ip dhcp snooping database command.
show ip dhcp snooping database [detail]
Syntax Description
detail |
(Optional) Provides additional operating state and statistics information. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(12c)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Added support of state and statistics information. |
Examples
This example shows how to display the DHCP snooping database:
Switch# show ip dhcp snooping database
Write delay Timer : 300 seconds
Abort Timer : 300 seconds
Delay Timer Expiry : Not Running
Abort Timer Expiry : Not Running
Last Succeded Time : None
Last Failed Reason : No failure recorded.
Total Attempts : 0 Startup Failures : 0
Successful Transfers : 0 Failed Transfers : 0
Successful Reads : 0 Failed Reads : 0
Successful Writes : 0 Failed Writes : 0
This example shows how to view additional operating statistics:
Switch# show ip dhcp snooping database detail
Agent URL : tftp://10.1.1.1/directory/file
Write delay Timer : 300 seconds
Abort Timer : 300 seconds
Delay Timer Expiry : 7 (00:00:07)
Abort Timer Expiry : Not Running
Last Succeded Time : None
Last Failed Time : 17:14:25 UTC Sat Jul 7 2001
Last Failed Reason : Unable to access URL.
Total Attempts : 21 Startup Failures : 0
Successful Transfers : 0 Failed Transfers : 21
Successful Reads : 0 Failed Reads : 0
Successful Writes : 0 Failed Writes : 21
First successful access: Read
Last ignored bindings counters :
Binding Collisions : 0 Expired leases : 0
Invalid interfaces : 0 Unsupported vlans : 0
Total ignored bindings counters:
Binding Collisions : 0 Expired leases : 0
Invalid interfaces : 0 Unsupported vlans : 0
Related Commands
ip dhcp snooping
ip dhcp snooping database
ip dhcp snooping information option
ip dhcp snooping limit rate
ip dhcp snooping trust
ip dhcp snooping vlan
show ip igmp interface
To view IP IGMP interface status and configuration information, use the show ip igmp interface command.
show ip igmp interface [fastethernet slot/port | gigabitethernet slot/port |
tengigabitethernet slot/port | null interface-number | vlan vlan_id]
Syntax Description
fastethernet slot/port |
(Optional) Specifies the Fast Ethernet interface and the number of the slot and port. |
gigabitethernet slot/port |
(Optional) Specifies the Gigabit Ethernet interface and the number of the slot and port; valid values are from 1 to 9. |
tengigabitethernet slot/port |
(Optional) Specifies the 10-Gigabit Ethernet interface and the number of the slot and port; valid values are from 1 to 2. |
null interface-number |
(Optional) Specifies the null interface and the number of the interface; the only valid value is 0. |
vlan vlan_id |
(Optional) Specifies the VLAN and the number of the VLAN; valid values are from 1 to 4094. |
Defaults
If you do not specify a VLAN, information for VLAN 1 is shown.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
If you omit the optional arguments, the show ip igmp interface command displays information about all interfaces.
Examples
This example shows how to view IGMP information for VLAN 200:
Switch# show ip igmp interface vlan 200
IGMP snooping is globally enabled
IGMP snooping is enabled on this Vlan
IGMP snooping immediate-leave is disabled on this Vlan
IGMP snooping mrouter learn mode is pim-dvmrp on this Vlan
IGMP snooping is running in IGMP-ONLY mode on this VLAN
Related Commands
clear ip igmp group
show ip igmp snooping mrouter
show ip igmp profile
To view all configured IGMP profiles or a specified IGMP profile, use the show ip igmp profile privileged EXEC command.
show ip igmp profile [profile number]
Syntax Description
profile number |
(Optional) IGMP profile number to be displayed; valid ranges are from 1 to 4294967295. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(11b)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
If no profile number is entered, all IGMP profiles are displayed.
Examples
This example shows how to display IGMP profile 40:
Switch# show ip igmp profile 40
range 233.1.1.1 233.255.255.255
This example shows how to display all IGMP profiles:
Switch# show ip igmp profile
range 230.9.9.0 230.9.9.0
range 229.9.9.0 229.255.255.255
Related Commands
ip igmp profile
show ip igmp snooping
To display information on dynamically learned and manually configured VLAN switch interfaces, use the show ip igmp snooping command.
show ip igmp snooping [querier | groups | mrouter] [vlan vlan_id] a.b.c.d [summary | sources | hosts] [count]
Syntax Description
querier |
(Optional) Specifies that the display will contain IP address and version information. |
groups |
(Optional) Specifies that the display will list VLAN members sorted by group IP addresses. |
mrouter |
(Optional) Specifies that the display will contain information on dynamically learned and manually configured multicast switch interfaces. |
vlan vlan_id |
(Optional) Specifies a VLAN; valid values are from 1 to 1001 and from 1006 to 4094. |
a.b.c.d |
Group or multicast IP address. |
summary |
(Optional) Specifies a display of detailed information for a v2 or v3 group. |
sources |
(Optional) Specifies a list of the source IPs for the specified group. |
hosts |
(Optional) Specifies a list of the host IPs for the specified group. |
count |
(Optional) Specifies a display of the total number of group addresses learned by the system on a global or per-VLAN basis. |
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Support for extended addressing was added. |
12.1(20)EW |
Added support to display configuration state for IGMPv3 explicit host tracking. |
Usage Guidelines
You can also use the show mac-address-table multicast command to display the entries in the MAC address table for a VLAN that has IGMP snooping enabled.
You can display IGMP snooping information for VLAN interfaces by entering the show ip igmp snooping command.
Examples
This example shows how to display the global snooping information on the switch:
Switch# show ip igmp snooping
Global IGMP Snooping configuration:
-----------------------------------
IGMPv3 snooping : Enabled
Report suppression : Enabled
TCN solicit query : Disabled
TCN flood query count : 2
IGMPv2 immediate leave : Disabled
Explicit host tracking : Enabled
Multicast router learning mode : pim-dvmrp
CGMP interoperability mode : IGMP_ONLY
IGMPv2 immediate leave : Disabled
Explicit host tracking : Enabled
Multicast router learning mode : pim-dvmrp
CGMP interoperability mode : IGMP_ONLY
This example shows how to display the snooping information on VLAN 2:
Switch# show ip igmp snooping vlan 2
Global IGMP Snooping configuration:
-----------------------------------
IGMPv3 snooping : Enabled
Report suppression : Enabled
TCN solicit query : Disabled
TCN flood query count : 2
IGMPv2 immediate leave : Disabled
Explicit host tracking : Enabled
Multicast router learning mode : pim-dvmrp
CGMP interoperability mode : IGMP_ONLY
This example shows how to display IGMP querier information for all VLANs on a switch:
Switch# show ip igmp snooping querier
Vlan IP Address IGMP Version Port
---------------------------------------------------
This example shows how to display IGMP querier information for VLAN 5 when running IGMPv2:
Switch# show ip igmp snooping querier vlan 5
This example shows how to display IGMP querier information for VLAN 5 when running IGMPv3:
Switch# show ip igmp snooping querier vlan 5
This example shows how to display snooping information for a specific group:
Switch#
show ip igmp snooping group
---------------------------------------------------------
This example shows how to display the group's host types and ports in VLAN 1:
Switch# show ip igmp snooping group vlan 1
Vlan Group Host Type Ports
---------------------------------------------------------
1 229.2.3.4 v3 fa2/1 fa2/3
This example shows how to display the group's host types and ports in VLAN 1:
Switch# show ip igmp snooping group vlan 10 226.6.6.7
---------------------------------------------------------
10 226.6.6.7 v3 Fa7/13, Fa7/14
This example shows how to display the current state of a group with respect to a source IP address:
Switch# show ip igmp snooping group vlan 10 226.6.6.7 sources
Source information for group 226.6.6.7:
Timers: Expired sources are deleted on next IGMP General Query
SourceIP Expires Uptime Inc Hosts Exc Hosts
-------------------------------------------------------
2.0.0.1 00:03:04 00:03:48 2 0
2.0.0.2 00:03:04 00:02:07 2 0
This example shows how to display the current state of a group with respect to a host MAC address:
Switch# show ip igmp snooping group vlan 10 226.6.6.7 hosts
IGMPv3 host information for group 226.6.6.7
Timers: Expired hosts are deleted on next IGMP General Query
Host (MAC/IP) Filter mode Expires Uptime # Sources
-------------------------------------------------------------
175.1.0.29 INCLUDE stopped 00:00:51 2
175.2.0.30 INCLUDE stopped 00:04:14 2
This example shows how to display summary information for a v3 group:
Switch# show ip igmp snooping group vlan 10 226.6.6.7 summary
Group Address (Vlan 10) : 226.6.6.7
Member Ports : Fa7/13, Fa7/14
Reporters (Include/Exclude) : 2/0
This example shows how to display multicast router information for VLAN 1:
Switch#
show ip igmp snooping mrouter vlan 1
-----+----------------------------------------
1 Gi1/1,Gi2/1,Fa3/48,Router
This example shows how to display the total number of group addresses learned by the system globally:
Switch# show ip igmp snooping group count
Total number of groups: 54
This example shows how to display the total number of group addresses learned on VLAN 5:
Switch# show ip igmp snooping group vlan 5 count
Total number of groups: 30
Related Commands
ip igmp snooping
ip igmp snooping vlan immediate-leave
ip igmp snooping vlan mrouter
ip igmp snooping vlan static
show ip igmp interface
show ip igmp snooping mrouter
show mac-address-table multicast
show ip igmp snooping membership
To display host membership information, use the show ip igmp snooping membership command.
show ip igmp snooping membership [interface interface_num] [vlan vlan_id]
[reporter a.b.c.d] [source a.b.c.d group a.b.c.d]
Syntax Description
interface interface_num |
(Optional) Displays IP address and version information of an interface. |
vlan vlan_id |
(Optional) Displays VLAN members sorted by group IP address of a VLAN; valid values are from 1 to 1001 and from 1006 to 4094. |
reporter a.b.c.d |
(Optional) Displays membership information for a specified reporter. |
source a.b.c.d |
(Optional) Specifies a reporter, source, or group IP address. |
group a.b.c.d |
(Optional) Displays all members of a channel (source, group), sorted by interface or VLAN. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(20)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
This command is valid only if explicit host tracking is enabled on the switch.
Examples
This example shows how to display host membership for the Gigabit Ethernet interface 4/1:
Switch# show ip igmp snooping membership interface gigabitethernet4/1
Source/Group Interface Reporter Uptime Last-Join Last-Leave
40.40.40.2/224.10.10.10 Gi4/1 20.20.20 .20 00:23: 37 00:06: 50 00:20:30
40.40.40.4/224.10.10.10 Gi4/1 20.20.20 .20 00:39: 42 00:09:17 -
This example shows how to display host membership for VLAN 20 and group 224.10.10.10:
Switch# show ip igmp snooping membership vlan 20 source 40.40.40.2 group 224.10.10.10
Source/Group Interface Reporter Uptime Last-Join Last-Leave
40.40.40.2/224.10.10.10 Gi4/1 20.20.20 .20 00:23: 37 00:06: 50 00:20:30
This example shows how to display host membership information for VLAN 20 and to delete the explicit host tracking:
Switch# show ip igmp snooping membership vlan 20
Snooping Membership Summary for Vlan 20
------------------------------------------
Total number of channels:5
Source/Group Interface Reporter Uptime Last-Join/
-------------------------------------------------------------------------------------------------------
40.0.0.1/224.1.1.1 Fa7/37 0002.4ba0.a4f6 00:00:04 00:00:04 /
40.0.0.2/224.1.1.1 Fa7/37 0002.fd80.f770 00:00:17 00:00:17 /
40.0.0.3/224.1.1.1 Fa7/36 20.20.20.20 00:00:04 00:00:04 /
40.0.0.4/224.1.1.1 Fa7/35 20.20.20.210 00:00:17 00:00:17 /
40.0.0.5/224.1.1.1 Fa7/37 0002.fd80.f770 00:00:17 00:00:17 /
Switch# clear ip igmp snooping membership vlan 20
Related Commands
clear ip igmp snooping membership
ip igmp snooping vlan explicit-tracking
show ip igmp snooping vlan
show ip igmp snooping mrouter
To display information on the dynamically learned and manually configured multicast switch interfaces, use the show ip igmp snooping mrouter command.
show ip igmp snooping mrouter [{vlan vlan-id}]
Syntax Description
vlan vlan-id |
(Optional) Specifies a VLAN; valid values are from 1 to 1001 and from 1006 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(19)EW |
Added support for extended VLAN addresses. |
Usage Guidelines
You can also use the show mac-address-table multicast command to display entries in the MAC address table for a VLAN that has IGMP snooping enabled.
You can display IGMP snooping information for the VLAN interfaces by entering the show ip igmp interface vlan vlan-num command.
Examples
This example shows how to display snooping information for a specific VLAN:
Switch#
show ip igmp snooping mrouter vlan 1
-----+----------------------------------------
1 Gi1/1,Gi2/1,Fa3/48,Switch
Related Commands
ip igmp snooping vlan mrouter
show ip igmp interface
show mac-address-table multicast
show ip igmp snooping vlan
To display information on the dynamically learned and manually configured VLAN switch interfaces, use the show ip igmp snooping vlan command.
show ip igmp snooping vlan vlan_num
Syntax Description
vlan_num |
Number of the VLAN; valid values are from 1 to 1001 and from 1006 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Support for extended addressing was added. |
Usage Guidelines
You can also use the show mac-address-table multicast command to display the entries in the MAC address table for a VLAN that has IGMP snooping enabled.
Examples
This example shows how to display snooping information for a specific VLAN:
Switch#
show ip igmp snooping vlan 2
IGMP snooping is globally enabled
IGMP snooping TCN solicit query is globally enabled
IGMP snooping global TCN flood query count is 2
IGMP snooping is enabled on this Vlan
IGMP snooping immediate-leave is disabled on this Vlan
IGMP snooping mrouter learn mode is pim-dvmrp on this Vlan
IGMP snooping is running in IGMP_ONLY mode on this Vlan
Related Commands
ip igmp snooping
ip igmp snooping vlan immediate-leave
ip igmp snooping vlan mrouter
ip igmp snooping vlan static
show ip igmp interface
show ip igmp snooping mrouter
show mac-address-table multicast
show ip interface
To display the usability status of interfaces that are configured for IP, use the show ip interface command.
show ip interface [type number]
Syntax Description
type |
(Optional) Interface type. |
number |
(Optional) Interface number. |
Defaults
This command has no default settings.
Command Modes
EXEC
Command History
|
|
12.2(25)EW |
Extended to include the 10-Gigabit Ethernet interface. |
Usage Guidelines
The Cisco IOS software automatically enters a directly connected route in the routing table if the interface is usable. A usable interface is one through which the software can send and receive packets. If the software determines that an interface is not usable, it removes the directly connected routing entry from the routing table. Removing the entry allows the software to use dynamic routing protocols to determine backup routes to the network, if any.
If the interface can provide two-way communication, the line protocol is marked "up." If the interface hardware is usable, the interface is marked "up."
If you specify an optional interface type, you see information only on that specific interface.
If you specify no optional arguments, you see information on all the interfaces.
When an asynchronous interface is encapsulated with PPP or Serial Line Internet Protocol (SLIP), IP fast switching is enabled. The show ip interface command on an asynchronous interface that is encapsulated with PPP or SLIP displays a message indicating that IP fast switching is enabled.
Examples
This example shows how to display the usability status for a specific VLAN:
Switch# show ip interface vlan 1
Vlan1 is up, line protocol is up
Internet address is 10.6.58.4/24
Broadcast address is 255.255.255.255
Address determined by non-volatile memory
Helper address is not set
Directed broadcast forwarding is disabled
Outgoing access list is not set
Inbound access list is not set
Local Proxy ARP is disabled
Security level is default
ICMP redirects are always sent
ICMP unreachables are always sent
ICMP mask replies are never sent
IP fast switching is enabled
IP fast switching on the same interface is disabled
IP Flow switching is disabled
IP CEF switching is enabled
IP Fast switching turbo vector
IP Normal CEF switching turbo vector
IP multicast fast switching is enabled
IP multicast distributed fast switching is disabled
IP route-cache flags are Fast, CEF
Router Discovery is disabled
IP output packet accounting is disabled
IP access violation accounting is disabled
TCP/IP header compression is disabled
RTP/IP header compression is disabled
Probe proxy name replies are disabled
Policy routing is disabled
Network address translation is disabled
WCCP Redirect outbound is disabled
WCCP Redirect inbound is disabled
WCCP Redirect exclude is disabled
BGP Policy Mapping is disabled
Sampled Netflow is disabled
IP multicast multilayer switching is disabled
Netflow Data Export (hardware) is enabled
Table 2-20 describes the fields that are shown in the example.
Table 2-20 show ip interface Field Descriptions
|
|
Ethernet0 is up |
If the interface hardware is usable, the interface is marked "up." For an interface to be usable, both the interface hardware and line protocol must be up. |
line protocol is up |
If the interface can provide two-way communication, the line protocol is marked "up." For an interface to be usable, both the interface hardware and line protocol must be up. |
Internet address and subnet mask |
IP address and subnet mask of the interface. |
Broadcast address |
Broadcast address. |
Address determined by... |
Status of how the IP address of the interface was determined. |
MTU |
MTU value that is set on the interface. |
Helper address |
Helper address, if one has been set. |
Secondary address |
Secondary address, if one has been set. |
Directed broadcast forwarding |
Status of directed broadcast forwarding. |
Multicast groups joined |
Multicast groups to which this interface belongs. |
Outgoing access list |
Status of whether the interface has an outgoing access list set. |
Inbound access list |
Status of whether the interface has an incoming access list set. |
Proxy ARP |
Status of whether Proxy Address Resolution Protocol (ARP) is enabled for the interface. |
Security level |
IP Security Option (IPSO) security level set for this interface. |
Split horizon |
Status of split horizon. |
ICMP redirects |
Status of the redirect messages on this interface. |
ICMP unreachables |
Status of the unreachable messages on this interface. |
ICMP mask replies |
Status of the mask replies on this interface. |
IP fast switching |
Status of whether fast switching has been enabled for this interface. Fast switching is typically enabled on serial interfaces, such as this one. |
IP SSE switching |
Status of the IP silicon switching engine (SSE). |
Router Discovery |
Status of the discovery process for this interface. It is typically disabled on serial interfaces. |
IP output packet accounting |
Status of IP accounting for this interface and the threshold (maximum number of entries). |
TCP/IP header compression |
Status of compression. |
Probe proxy name |
Status of whether the HP Probe proxy name replies are generated. |
WCCP Redirect outbound is enabled |
Status of whether packets that are received on an interface are redirected to a cache engine. |
WCCP Redirect exclude is disabled |
Status of whether packets that are targeted for an interface are excluded from being redirected to a cache engine. |
Netflow Data Export (hardware) is enabled |
NDE hardware flow status on the interface. |
show ip mfib
To display all active Multicast Forwarding Information Base (MFIB) routes, use the show ip mfib command.
show ip mfib [all | counters | log [n]]
Syntax Description
all |
(Optional) Specifies all routes in the MFIB, including those routes that are used to accelerate fast switching but that are not necessarily in the upper-layer routing protocol table. |
counters |
(Optional) Specifies the counts of MFIB-related events. Only nonzero counters are shown. |
log |
(Optional) Specifies a log of the most recent number of MFIB-related events. The most recent event is first. |
n |
(Optional) Number of events. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The MFIB table contains a set of IP multicast routes; each route in the MFIB table contains several flags that associate to the route.
The route flags indicate how a packet that matches a route is forwarded. For example, the IC flag on an MFIB route indicates that some process on the switch needs to receive a copy of the packet. These flags are associated with MFIB routes:
•
Internal Copy (IC) flag—Set on a route when a process on the switch needs to receive a copy of all packets matching the specified route.
•
Signaling (S) flag—Set on a route when a switch process needs notification that a packet matching the route is received. In the expected behavior, the protocol code updates the MFIB state in response to having received a packet on a signaling interface.
•
Connected (C) flag—When set on a route, the C flag has the same meaning as the S flag, except that the C flag indicates that only packets sent by directly connected hosts to the route should be signaled to a protocol process.
A route can also have a set of flags associated with one or more interfaces. For an (S,G) route, the flags on interface 1 indicate how the ingress packets should be treated and whether packets matching the route should be forwarded onto interface 1. These per-interface flags are associated with the MFIB routes:
•
Accepting (A)—Set on the RPF interface when a packet that arrives on the interface and that is marked as Accepting (A) is forwarded to all Forwarding (F) interfaces.
•
Forwarding (F)—Used with the A flag as described above. The set of forwarding interfaces together form a multicast olist or output interface list.
•
Signaling (S)—Set on an interface when a multicast routing protocol process in Cisco IOS needs to be notified of ingress packets on that interface.
•
Not Platform (NP) fast-switched—Used with the F flag. A forwarding interface is also marked as Not Platform fast-switched whenever that output interface cannot be fast-switched by the platform hardware and requires software forwarding.
For example, the Catalyst 4006 switch with Supervisor Engine III cannot switch tunnel interfaces in hardware so these interfaces are marked with the NP flag. When an NP interface is associated with a route, a copy of every ingress packet arriving on an Accepting interface is sent to the switch software forwarding path for software replication and then forwarded to the NP interface.
Examples
This example shows how to display all active MFIB routes:
IP Multicast Forwarding Information Base
Entry Flags: C - Directly Connected, S - Signal,
Interface Flags: A - Accept, F - Forward, NS - Signal,
NP - Not platform switched
Packets: Fast/Partial/Slow Bytes: Fast/Partial/Slow:
(171.69.10.13, 224.0.1.40), flags (IC)
Packets: 2292/2292/0, Bytes: 518803/0/518803
(*, 224.0.1.60), flags ()
Packets: 2292/0/0, Bytes: 518803/0/0
(*, 224.0.1.75), flags ()
(10.34.2.92, 239.192.128.80), flags ()
Packets: 24579/100/0, 2113788/15000/0 bytes
(*, 239.193.100.70), flags ()
Packets: 1/0/0, 1500/0/0 bytes
Related Commands
clear ip mfib counters
show ip mfib fastdrop
To show all currently active fast-drop entries and to show whether fast drop is enabled, use the show ip mfib fastdrop command.
show ip mfib fastdrop
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display all currently active fast-drop entries and whether fast drop is enabled.
Switch# show ip mfib fasttdrop
MFIB fastdrop is enabled.
(10.0.0.1, 224.1.2.3, Vlan9 ) 00:01:32
(10.1.0.2, 224.1.2.3, Vlan9 ) 00:02:30
(1.2.3.4, 225.6.7.8, Vlan3) 00:01:50
Related Commands
clear ip mfib fastdrop
show ip mroute
To display IP multicast routing table information, use the show ip mroute command.
show ip mroute [interface_type slot/port | host_name | host_address [source] | active [kbps | interface_type num] | count | pruned | static | summary]
Syntax Description
interface_type slot/port |
(Optional) Interface type and number of the slot and port; valid values for interface type are fastethernet, gigabitethernet, tengigabitethernet, null, and vlan. |
host_name |
(Optional) Name or IP address as defined in the DNS hosts table. |
host_address source |
(Optional) IP address or name of a multicast source. |
active |
(Optional) Displays the rate that active sources are sending to multicast groups. |
kbps interface_type num |
(Optional) Minimum rate at which active sources are sending to multicast groups; active sources sending at this rate or greater will be displayed. Valid values are from 1 to 4294967295 kbps. |
count |
(Optional) Displays the route and packet count information. |
pruned |
(Optional) Displays the pruned routes. |
static |
(Optional) Displays the static multicast routes. |
summary |
(Optional) Displays a one-line, abbreviated summary of each entry in the IP multicast routing table. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
If you omit all the optional arguments and keywords, the show ip mroute command displays all the entries in the IP multicast routing table.
The show ip mroute active kbps command displays all the sources sending at a rate greater than or equal to kbps.
The multicast routing table is populated by creating source, group (S,G) entries from star, group (*,G) entries. The star refers to all source addresses, the "S" refers to a single source address, and the "G" refers to the destination multicast group address. In creating (S,G) entries, the software uses the best path to that destination group found in the unicast routing table (through Reverse Path Forwarding (RPF).
Examples
This example shows how to display all the entries in the IP multicast routing table:
IP Multicast Routing Table
Flags:D - Dense, S - Sparse, s - SSM Group, C - Connected, L - Local,
P - Pruned, R - RP-bit set, F - Register flag, T - SPT-bit set,
J - Join SPT, M - MSDP created entry, X - Proxy Join Timer Running
A - Advertised via MSDP, U - URD, I - Received Source Specific Host
Outgoing interface flags:H - Hardware switched
Interface state:Interface, Next-Hop or VCD, State/Mode
(*, 230.13.13.1), 00:16:41/00:00:00, RP 10.15.1.20, flags:SJC
Incoming interface:GigabitEthernet4/8, RPF nbr 10.15.1.20
GigabitEthernet4/9, Forward/Sparse-Dense, 00:16:41/00:00:00, H
(*, 230.13.13.2), 00:16:41/00:00:00, RP 10.15.1.20, flags:SJC
Incoming interface:GigabitEthernet4/8, RPF nbr 10.15.1.20, RPF-MFD
GigabitEthernet4/9, Forward/Sparse-Dense, 00:16:41/00:00:00, H
(10.20.1.15, 230.13.13.1), 00:14:31/00:01:40, flags:CJT
Incoming interface:GigabitEthernet4/8, RPF nbr 10.15.1.20, RPF-MFD
GigabitEthernet4/9, Forward/Sparse-Dense, 00:14:31/00:00:00, H
(132.206.72.28, 224.2.136.89), 00:14:31/00:01:40, flags:CJT
Incoming interface:GigabitEthernet4/8, RPF nbr 10.15.1.20, RPF-MFD
Outgoing interface list:Null
This example shows how to display the rate that the active sources are sending to the multicast groups and to display only the active sources that are sending at greater than the default rate:
Switch# show ip mroute active
Active IP Multicast Sources - sending > = 4 kbps
Group: 224.2.127.254, (sdr.cisco.com)
Source: 146.137.28.69 (mbone.ipd.anl.gov)
Rate: 1 pps/4 kbps(1sec), 4 kbps(last 1 secs), 4 kbps(life avg)
Group: 224.2.201.241, ACM 97
Source: 130.129.52.160 (webcast3-e1.acm97.interop.net)
Rate: 9 pps/93 kbps(1sec), 145 kbps(last 20 secs), 85 kbps(life avg)
Group: 224.2.207.215, ACM 97
Source: 130.129.52.160 (webcast3-e1.acm97.interop.net)
Rate: 3 pps/31 kbps(1sec), 63 kbps(last 19 secs), 65 kbps(life avg)
This example shows how to display route and packet count information:
Switch# show ip mroute count
56 routes using 28552 bytes of memory
13 groups, 3.30 average sources per group
Forwarding Counts:Pkt Count/Pkts per second/Avg Pkt Size/Kilobits per second
Other counts:Total/RPF failed/Other drops(OIF-null, rate-limit etc)
Group:224.2.136.89, Source count:1, Group pkt count:29051
Source:132.206.72.28/32, Forwarding:29051/-278/1186/0, Other:85724/8/56665
This example shows how to display summary information:
Switch# show ip mroute summary
IP Multicast Routing Table
Flags: D - Dense, S - Sparse, s - SSM Group, C - Connected, L - Local,
P - Pruned, R - RP-bit set, F - Register flag, T - SPT-bit set,
J - Join SPT, M - MSDP created entry, X - Proxy Join Timer Running
A - Advertised via MSDP, U - URD, I - Received Source Specific Host
Outgoing interface flags: H - Hardware switched
Interface state: Interface, Next-Hop or VCD, State/Mode
Table 2-21 describes the fields shown in the output.
Table 2-21 show ip mroute Field Descriptions
|
|
Flags: |
Information about the entry. |
D - Dense |
Entry is operating in dense mode. |
S - Sparse |
Entry is operating in sparse mode. |
s - SSM Group |
Entry is a member of an SSM group. |
C - Connected |
Member of the multicast group is present on the directly connected interface. |
L - Local |
Switch is a member of the multicast group. |
P - Pruned |
Route has been pruned. This information is retained in case a downstream member wants to join the source. |
R - Rp-bit set |
Status of the (S,G) entry; is the (S,G) entry pointing toward the RP. The R - Rp-bit set is typically a prune state along the shared tree for a particular source. |
F - Register flag |
Status of the software; indicates if the software is registered for a multicast source. |
T - SPT-bit set |
Status of the packets; indicates if the packets been received on the shortest path source tree. |
J - Join SPT |
For (*, G) entries, indicates that the rate of traffic flowing down the shared tree is exceeding the SPT-Threshold set for the group. (The default SPT-Threshold setting is 0 kbps.) When the J - Join SPT flag is set, the next (S,G) packet received down the shared tree triggers an (S,G) join in the direction of the source causing the switch to join the source tree. For (S, G) entries, indicates that the entry was created because the SPT-Threshold for the group was exceeded. When the J - Join SPT flag is set for (S,G) entries, the switch monitors the traffic rate on the source tree and attempts to switch back to the shared tree for this source if the traffic rate on the source tree falls below the group's SPT-Threshold for more than one minute. The switch measures the traffic rate on the shared tree and compares the measured rate to the group's SPT-Threshold once every second. If the traffic rate exceeds the SPT-Threshold, the J- Join SPT flag is set on the (*, G) entry until the next measurement of the traffic rate. The flag is cleared when the next packet arrives on the shared tree and a new measurement interval is started. If the default SPT-Threshold value of 0 Kbps is used for the group, the J- Join SPT flag is always set on (*, G) entries and is never cleared. When the default SPT-Threshold value is used, the switch immediately switches to the shortest-path tree when traffic from a new source is received. |
Outgoing interface flag: |
Information about the outgoing entry. |
H - Hardware switched |
Entry is hardware switched. |
Timer: |
Uptime/Expires. |
Interface state: |
Interface, Next-Hop or VCD, State/Mode. |
(*, 224.0.255.1) (198.92.37.100/32, 224.0.255.1) |
Entry in the IP multicast routing table. The entry consists of the IP address of the source switch followed by the IP address of the multicast group. An asterisk (*) in place of the source switch indicates all sources. Entries in the first format are referred to as (*,G) or "star comma G" entries. Entries in the second format are referred to as (S,G) or "S comma G" entries. (*,G) entries are used to build (S,G) entries. |
uptime |
How long (in hours, minutes, and seconds) the entry has been in the IP multicast routing table. |
expires |
How long (in hours, minutes, and seconds) until the entry is removed from the IP multicast routing table on the outgoing interface. |
RP |
Address of the RP switch. For switches and access servers operating in sparse mode, this address is always 0.0.0.0. |
flags: |
Information about the entry. |
Incoming interface |
Expected interface for a multicast packet from the source. If the packet is not received on this interface, it is discarded. |
RPF neighbor |
IP address of the upstream switch to the source. "Tunneling" indicates that this switch is sending data to the RP encapsulated in Register packets. The hexadecimal number in parentheses indicates to which RP it is registering. Each bit indicates a different RP if multiple RPs per group are used. |
DVMRP or Mroute |
Status of whether the RPF information is obtained from the DVMRP routing table or the static mroutes configuration. |
Outgoing interface list |
Interfaces through which packets are forwarded. When the ip pim nbma-mode command is enabled on the interface, the IP address of the PIM neighbor is also displayed. |
Ethernet0 |
Name and number of the outgoing interface. |
Next hop or VCD |
Next hop specifies downstream neighbor's IP address. VCD specifies the virtual circuit descriptor number. VCD0 indicates that the group is using the static-map virtual circuit. |
Forward/Dense |
Status of the packets; indicates if they are they forwarded on the interface if there are no restrictions due to access lists or the TTL threshold. Following the slash (/), mode in which the interface is operating (dense or sparse). |
Forward/Sparse |
Sparse mode interface is in forward mode. |
time/time (uptime/expiration time) |
Per interface, how long (in hours, minutes, and seconds) the entry has been in the IP multicast routing table. Following the slash (/), how long (in hours, minutes, and seconds) until the entry is removed from the IP multicast routing table. |
Related Commands
ip multicast-routing (refer to Cisco IOS documentation)
ip pim (refer to Cisco IOS documentation)
show ip source binding
To display IP source bindings that are configured on the system, use the show ip source binding EXEC command.
show ip source binding [ip-address] [mac-address] [dhcp-snooping | static] [vlan vlan-id] [interface interface-name]
Syntax Description
ip-address |
(Optional) Binding IP address. |
mac-address |
(Optional) Binding MAC address. |
dhcp-snooping |
(Optional) DHCP-snooping type binding. |
static |
(Optional) Statically configured binding. |
vlan vlan-id |
(Optional) VLAN number. |
interface interface-name |
(Optional) Binding interface. |
Defaults
Displays both static and DHCP snooping bindings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The optional parameters filter the display output result.
Examples
This example shows how to display the IP source bindings:
Switch# show ip source binding
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------------- ---- --------------------
00:00:00:0A:00:0B 11.0.0.1 infinite static 10 FastEthernet6/10
This example shows how to display the static IP binding entry of IP address 11.0.01:
Switch# show ip source binding 11.0.0.1 0000.000A.000B static vlan 10 interface Fa6/10
show ip source binding 11.0.0.1 0000.000A.000B static vlan 10 interface Fa6/10
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------------- ---- --------------------
00:00:00:0A:00:0B 11.0.0.1 infinite static 10 FastEthernet6/10
Switch#
Related Commands
ip source binding
show ip verify source
To display the IP source guard configuration and filters on a particular interface, use the show ip verify source command.
show ip verify source [interface interface_num]
Syntax Description
interface interface_num |
(Optional) Specifies an interface. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
These examples show how to display the IP source guard configuration and filters on a particular interface with the show ip verify source interface command:
•
This output appears when DHCP snooping is enabled on VLANs 10-20, interface fa6/1 has IP source filter mode that is configured as IP, and an existing IP address binding 10.0.0.1 is on VLAN 10:
Interface Filter-type Filter-mode IP-address Mac-address Vlan
--------- ----------- ----------- --------------- -------------- ---------
fa6/1 ip active 10.0.0.1 10
fa6/1 ip active deny-all 11-20
Note
The second entry shows that a default PVACL (deny all IP traffic) is installed on the port for those snooping-enabled VLANs that do not have a valid IP source binding.
•
This output appears when you enter the show ip verify source interface fa6/2 command and DHCP snooping is enabled on VLANs 10-20, interface fa6/1 has IP source filter mode that is configured as IP, and there is an existing IP address binding 10.0.0.1 on VLAN 10:
Interface Filter-type Filter-mode IP-address Mac-address Vlan
--------- ----------- ----------- --------------- -------------- ---------
fa6/2 ip inactive-trust-port
•
This output appears when you enter the show ip verify source interface fa6/3 command and the interface fa6/3 does not have a VLAN enabled for DHCP snooping:
Interface Filter-type Filter-mode IP-address Mac-address Vlan
--------- ----------- ----------- --------------- -------------- ---------
fa6/3 ip inactive-no-snooping-vlan
•
This output appears when you enter the show ip verify source interface fa6/4 command and the interface fa6/4 has an IP source filter mode that is configured as IP MAC and the existing IP MAC that binds 10.0.0.2/aaaa.bbbb.cccc on VLAN 10 and 11.0.0.1/aaaa.bbbb.cccd on VLAN 11:
Interface Filter-type Filter-mode IP-address Mac-address Vlan
--------- ----------- ----------- --------------- -------------- ---------
fa6/4 ip-mac active 10.0.0.2 aaaa.bbbb.cccc 10
fa6/4 ip-mac active 11.0.0.1 aaaa.bbbb.cccd 11
fa6/4 ip-mac active deny-all deny-all 12-20
•
This output appears when you enter the show ip verify source interface fa6/5 command and the interface fa6/5 has IP source filter mode that is configured as IP MAC and existing IP MAC binding 10.0.0.3/aaaa.bbbb.ccce on VLAN 10, but port security is not enabled on fa6/5:
Interface Filter-type Filter-mode IP-address Mac-address Vlan
--------- ----------- ----------- --------------- -------------- ---------
fa6/5 ip-mac active 10.0.0.3 permit-all 10
fa6/5 ip-mac active deny-all permit-all 11-20
Note
Enable port security first because the DHCP security MAC filter cannot apply to the port or VLAN.
•
This output appears when you enter the show ip verify source interface fa6/6 command and the interface fa6/6 does not have IP source filter mode that is configured:
DHCP security is not configured on the interface fa6/6.
This example shows how to display all the interfaces on the switch that have DHCP snooping security enabled with the show ip verify source command.
The output is an accumulation of per-interface show CLIs:
Interface Filter-type Filter-mode IP-address Mac-address Vlan
--------- ----------- ----------- --------------- -------------- ---------
fa6/1 ip active 10.0.0.1 10
fa6/1 ip active deny-all 11-20
fa6/2 ip inactive-trust-port
fa6/3 ip inactive-no-snooping-vlan
fa6/4 ip-mac active 10.0.0.2 aaaa.bbbb.cccc 10
fa6/4 ip-mac active 11.0.0.1 aaaa.bbbb.cccd 11
fa6/4 ip-mac active deny-all deny-all 12-20
fa6/5 ip-mac active 10.0.0.3 permit-all 10
fa6/5 ip-mac active deny-all permit-all 11-20
Related Commands
ip dhcp snooping information option
ip dhcp snooping limit rate
ip dhcp snooping trust
ip igmp snooping
ip igmp snooping vlan
ip source binding
ip verify source vlan dhcp-snooping
show ip source binding
show ipc
To display IPC information, use the show ipc command.
show ipc {nodes | ports | queue | status}
Syntax Description
nodes |
Displays the participating nodes. |
ports |
Displays the local IPC ports. |
queue |
Displays the contents of the IPC retransmission queue. |
status |
Displays the status of the local IPC server. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(12c)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display the participating nodes:
There are 3 nodes in this IPC realm.
10000 Local IPC Master 0 0
2010000 Local GALIOS IPC:Card 1 0 0
2020000 Ethernet GALIOS IPC:Card 2 12 26
This example shows how to display the local IPC ports:
There are 11 ports defined.
Port ID Type Name (current/peak/total)
10000.1 unicast IPC Master:Zone
10000.2 unicast IPC Master:Echo
10000.3 unicast IPC Master:Control
10000.4 unicast Remote TTY Server Port
10000.5 unicast GALIOS RF :Active
index = 0 seat_id = 0x2020000 last sent = 0 heard = 1635 0/1/1635
10000.6 unicast GALIOS RED:Active
index = 0 seat_id = 0x2020000 last sent = 0 heard = 2 0/1/2
2020000.3 unicast GALIOS IPC:Card 2:Control
2020000.4 unicast GALIOS RFS :Standby
2020000.5 unicast Slave: Remote TTY Client Port
2020000.6 unicast GALIOS RF :Standby
2020000.7 unicast GALIOS RED:Standby
RPC packets: current/peak/total
This example shows how to display the contents of the IPC retransmission queue:
There are 0 IPC messages waiting for acknowledgement in the transmit queue.
There are 0 IPC messages waiting for a response.
There are 0 IPC messages waiting for additional fragments.
There are 0 IPC messages currently on the IPC inboundQ.
There are 0 messages currently in use by the system.
This example shows how to display the status of the local IPC server:
This processor is the IPC master server.
6000 IPC message headers in cache
3363 messages in, 1680 out, 1660 delivered to local port,
1686 acknowledgements received, 1675 sent,
0 NACKS received, 0 sent,
0 messages dropped on input, 0 messages dropped on output
0 no local port, 0 destination unknown, 0 no transport
0 missing callback or queue, 0 duplicate ACKs, 0 retries,
0 ipc_output failures, 0 mtu failures,
0 msg alloc failed, 0 emer msg alloc failed, 0 no origs for RPC replies
0 pak alloc failed, 0 memd alloc failed
0 no hwq, 1 failed opens, 0 hardware errors
No regular dropping of IPC output packets for test purposes
show l2protocol-tunnel
To display information about the Layer 2 protocol tunnel ports, use the show l2protocol-tunnel command. This command displays information for the interfaces with protocol tunneling enabled.
show l2protocol-tunnel [interface interface-id] [[summary] | {begin | exclude | include} expression]
Syntax Description
interface interface-id |
(Optional) Specifies the interface for which protocol tunneling information appears. Valid interfaces are physical ports and port channels; the port channel range is 1 to 64. |
summary |
(Optional) Displays only Layer 2 protocol summary information. |
begin |
(Optional) Displays information beginning with the line that matches the expression. |
exclude |
(Optional) Displays information that excludes lines that match the expression. |
include |
(Optional) Displays the lines that match the specified expression. |
expression |
(Optional) Expression in the output to use as a reference point. |
Command Modes
User EXEC
Command History
|
|
12.2(18)EW |
This command was first introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
After enabling Layer 2 protocol tunneling on an access or 802.1Q tunnel port with the l2protocol-tunnel command, you can configure some or all of these parameters:
•
Protocol type to be tunneled
•
Shutdown threshold
•
Drop threshold
If you enter the show l2protocol-tunnel [interface interface-id] command, only information about the active ports on which all the parameters are configured appears.
If you enter the show l2protocol-tunnel summary command, only information about the active ports on which some or all of the parameters are configured appears.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show l2protocol-tunnel command:
Switch> show l2protocol-tunnel
COS for Encapsulated Packets: 5
Port Protocol Shutdown Drop Encapsulation Decapsulation Drop
Threshold Threshold Counter Counter Counter
------- -------- --------- --------- ------------- ------------- -------------
Fa0/10 --- ---- ---- ---- ---- ----
stp ---- ---- 9847 1866 0
Fa0/11 cdp 1100 ---- 2356 2350 0
Fa0/12 cdp ---- ---- 2356 0 0
Fa0/13 cdp ---- ---- 2356 0 0
This is an example of output from the show l2protocol-tunnel summary command:
Switch> show l2protocol-tunnel summary
COS for Encapsulated Packets: 5
Port Protocol Shutdown Drop Status
(cdp/stp/vtp) (cdp/stp/vtp)
(pagp/lacp/udld) (pagp/lacp/udld)
------- ----------- ---------------- ---------------- ----------
Fa0/10 --- stp vtp ----/----/---- ----/----/---- up
pagp lacp udld ----/----/---- ----/----/----
Fa0/11 cdp stp vtp 1100/1100/1100 ----/----/---- up
pagp lacp udld ----/----/---- 900/ 900/ 900
Fa0/12 cdp stp vtp ----/----/---- ----/----/---- up
pagp lacp udld ----/----/---- ----/----/----
Fa0/13 cdp stp vtp ----/----/---- ----/----/---- up
pagp lacp udld ----/----/---- ----/----/----
Fa0/14 cdp stp vtp ----/----/---- ----/----/---- down
pagp ---- udld ----/----/---- ----/----/----
Fa0/15 cdp stp vtp ----/----/---- ----/----/---- down
pagp ---- udld ----/----/---- ----/----/----
Fa0/16 cdp stp vtp ----/----/---- ----/----/---- down
pagp lacp udld ----/----/---- ----/----/----
Fa0/17 cdp stp vtp ----/----/---- ----/----/---- down
pagp lacp udld ----/----/---- ----/----/----
Related Commands
clear I2protocol-tunnel counter (refer to Cisco IOS documentation)
l2protocol-tunnel
l2protocol-tunnel cos
show lacp
To display LACP information, use the show lacp command.
show lacp [channel-group] {counters | internal | neighbors | sys-id}
Syntax Description
channel-group |
(Optional) Number of the channel group; valid values are from 1 to 64. |
counters |
Displays the LACP statistical information. |
internal |
Displays the internal information. |
neighbors |
Displays the neighbor information. |
sys-id |
Displays the LACP system identification. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(13)EW |
Support for this command was introduced on the Catalyst 4500 series switches. |
Usage Guidelines
This command is not supported on systems that are configured with a Supervisor Engine I.
If you do not specify a channel-group value, all channel groups are displayed.
You can enter the optional channel-group value to specify a channel group for all keywords, except the sys-id keyword.
Examples
This example shows how to display LACP statistical information for a specific channel group:
Switch# show lacp 1 counters
Port Sent Recv Sent Recv Pkts Err
---------------------------------------------------
The output displays the following information:
•
The LACPDUs Sent and Recv columns display the LACPDUs sent and received on each specific interface.
•
The LACPDUs Pkts and Err columns display the marker protocol packets.
This example shows how to display internal information for the interfaces belonging to a specific channel:
Switch# show lacp 1 internal
Flags: S - Device sends PDUs at slow rate. F - Device sends PDUs at fast rate.
A - Device is in Active mode. P - Device is in Passive mode.
LACPDUs LACP Port Admin Oper Port Port
Port Flags State Interval Priority Key Key Number State
Fa4/1 saC bndl 30s 32768 100 100 0xc1 0x75
Fa4/2 saC bndl 30s 32768 100 100 0xc2 0x75
Fa4/3 saC bndl 30s 32768 100 100 0xc3 0x75
Fa4/4 saC bndl 30s 32768 100 100 0xc4 0x75
Table 2-22 lists the output field definitions.
Table 2-22 show lacp internal Command Output Fields
|
|
State |
State of the specific port at the current moment is displayed; allowed values are as follows: • bndl—Port is attached to an aggregator and bundled with other ports. • susp—Port is in a suspended state; it is not attached to any aggregator. • indep—Port is in an independent state (not bundled but able to switch data traffic. In this case, LACP is not running on the partner port). • hot-sby—Port is in a Hot-standby state. • down—Port is down. |
LACPDUs Interval |
Interval setting. |
LACP Port Priority |
Port priority setting. |
Admin Key |
Administrative key. |
Oper Key |
Operator key. |
Port Number |
Port number. |
Port State |
State variables for the port encoded as individual bits within a single octet with the following meaning [1]: • bit0: LACP_Activity • bit1: LACP_Timeout • bit2: Aggregation • bit3: Synchronization • bit4: Collecting • bit5: Distributing • bit6: Defaulted • bit7: Expired |
This example shows how to display LACP neighbors information for a specific port channel:
Switch# show lacp 1 neighbor
Flags: S - Device sends PDUs at slow rate. F - Device sends PDUs at fast rate.
A - Device is in Active mode. P - Device is in Passive mode.
Channel group 1 neighbors
Port System ID Port Number Age Flags
Fa4/1 8000,00b0.c23e.d84e 0x81 29s P
Fa4/2 8000,00b0.c23e.d84e 0x82 0s P
Fa4/3 8000,00b0.c23e.d84e 0x83 0s P
Fa4/4 8000,00b0.c23e.d84e 0x84 0s P
In the case where no PDUs have been received, the default administrative information is displayed in braces.
This example shows how to display the LACP system identification:
The system identification is made up of the system priority and the system MAC address. The first two bytes are the system priority, and the last six bytes are the globally administered individual MAC address associated to the system.
Related Commands
lacp port-priority
lacp system-priority
show mac access-group interface
To display the ACL configuration on a Layer 2 interface, use the show mac access-group interface command.
show mac access-group interface [interface interface-number]
Syntax Description
interface |
(Optional) Specifies the interface type; valid values are ethernet, fastethernet, gigabitethernet, tengigabitethernet, pos, atm, port-channel, and ge-wan. |
interface-number |
(Optional) Specifies the port number. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(19)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The valid values for the port number depend on the chassis used.
Examples
This example shows how to display the ACL configuration on interface fast 6/1:
Switch# show mac access-group interface fast 6/1
Interface FastEthernet6/1:
Inbound access-list is simple-mac-acl
Outbound access-list is not set
Related Commands
access-group mode
show mac-address-table address
To display MAC address table information for a specific MAC address, use the
show mac-address-table address command.
show mac-address-table address mac_addr [interface type slot/port | protocol protocol | vlan vlan_id]
Syntax Description
mac_addr |
48-bit MAC address; the valid format is H.H.H. |
interface type slot/port |
(Optional) Displays information for a specific interface; valid values for type are fastethernet, gigabitethernet, and tengigabitethernet. |
protocol protocol |
(Optional) Specifies a protocol. See the "Usage Guidelines" section for more information. |
vlan vlan_id |
(Optional) Displays entries for the specific VLAN only; valid values are from 1 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
For the MAC address table entries that are used by the routed ports, the routed port name is displayed in the "vlan" column not the internal VLAN number.
The keyword definitions for the protocol variable are as follows:
•
ip specifies the IP protocol.
•
ipx specifies the IPX protocols.
•
assigned specifies the assigned protocol entries.
•
other specifies the other protocol entries.
Examples
This example shows how to display MAC address table information for a specific MAC address:
Switch# show mac-address-table address 0030.94fc.0dff
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/2 0030.94fc.0dff static ip,ipx,assigned,other Switch
Related Commands
show mac-address-table aging-time
show mac-address-table count
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table multicast
show mac-address-table protocol
show mac-address-table static
show mac-address-table vlan
show mac-address-table aging-time
To display the MAC address aging time, use the show mac-address-table aging-time command.
show mac-address-table aging-time [vlan vlan_id]
Syntax Description
vlan vlan_id |
(Optional) Specifies a VLAN; valid values are from 1 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Support for extended addressing was added. |
Examples
This example shows how to display the currently configured aging time for all VLANs:
Switch#
show mac-address-table aging-time
This example shows how to display the currently configured aging time for a specific VLAN:
Switch#
show mac-address-table aging-time vlan 100
Related Commands
show mac-address-table address
show mac-address-table count
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table multicast
show mac-address-table protocol
show mac-address-table static
show mac-address-table vlan
show mac-address-table count
To display the number of entries currently in the MAC address table, use the show mac-address-table count command.
show mac-address-table count [vlan vlan_id]
Syntax Description
vlan vlan_id |
(Optional) Specifies a VLAN; valid values are from 1 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
Examples
This example shows how to display the entry count for a specific VLAN:
Switch# show mac-address-table count vlan 1
Dynamic Unicast Address Count: 0
Static Unicast Address (User-defined) Count: 0
Static Unicast Address (System-defined) Count: 1
Total Unicast MAC Addresses In Use: 1
Total Unicast MAC Addresses Available: 32768
Multicast MAC Address Count: 1
Total Multicast MAC Addresses Available: 16384
Related Commands
show mac-address-table address
show mac-address-table aging-time
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table multicast
show mac-address-table protocol
show mac-address-table static
show mac-address-table vlan
show mac-address-table dynamic
To display the dynamic MAC address table entries only, use the show mac-address-table dynamic command.
show mac-address-table dynamic [address mac_addr | interface type slot/port |
protocol protocol | vlan vlan_id]
Syntax Description
address mac_addr |
(Optional) Specifies a 48-bit MAC address; the valid format is H.H.H. |
interface type slot/port |
(Optional) Specifies an interface to match; valid values for type are fastethernet, gigabitethernet, and tengigabitethernet. |
protocol protocol |
(Optional) Specifies a protocol. See the "Usage Guidelines" section for more information. |
vlan vlan_id |
(Optional) Displays entries for a specific VLAN; valid values are from 1 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
The keyword definitions for the protocol argument are as follows:
•
assigned specifies assigned protocol entries.
•
ip specifies IP protocol.
•
ipx specifies IPX protocols.
•
other specifies other protocol entries.
The show mac-address-table dynamic command output for an EtherChannel interface changes the port number designation (such as, 5/7) to a port group number (such as, Po80).
For the MAC address table entries that are used by the routed ports, the routed port name is displayed in the "vlan" column not the internal VLAN number.
Examples
This example shows how to display all the dynamic MAC address entries:
Switch# show mac-address-table dynamic
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0000.0000.0201 dynamic ip FastEthernet6/15
1 0000.0000.0202 dynamic ip FastEthernet6/15
1 0000.0000.0203 dynamic ip,assigned FastEthernet6/15
1 0000.0000.0204 dynamic ip,assigned FastEthernet6/15
1 0000.0000.0205 dynamic ip,assigned FastEthernet6/15
2 0000.0000.0101 dynamic ip FastEthernet6/16
2 0000.0000.0102 dynamic ip FastEthernet6/16
2 0000.0000.0103 dynamic ip,assigned FastEthernet6/16
2 0000.0000.0104 dynamic ip,assigned FastEthernet6/16
2 0000.0000.0105 dynamic ip,assigned FastEthernet6/16
This example shows how to display the dynamic MAC address entries with a specific protocol type (in this case, assigned):
Switch# show mac-address-table dynamic protocol assigned
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0000.0000.0203 dynamic ip,assigned FastEthernet6/15
1 0000.0000.0204 dynamic ip,assigned FastEthernet6/15
1 0000.0000.0205 dynamic ip,assigned FastEthernet6/15
2 0000.0000.0103 dynamic ip,assigned FastEthernet6/16
2 0000.0000.0104 dynamic ip,assigned FastEthernet6/16
2 0000.0000.0105 dynamic ip,assigned FastEthernet6/16
Related Commands
show mac-address-table protocol
show mac-address-table static
show mac-address-table vlan
show mac-address-table interface
To display the MAC address table information for a specific interface, use the
show mac-address-table interface command.
show mac-address-table interface type slot/port
Syntax Description
type |
Interface type; valid values are ethernet, fastethernet, gigabitethernet, and tengigabitethernet. |
slot/port |
Number of the slot and port. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
For the MAC address table entries that are used by the routed ports, the routed port name is displayed in the "vlan" column not the internal VLAN number.
Examples
This example shows how to display MAC address table information for a specific interface:
Switch# show mac-address-table interface fastethernet6/16
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
2 0000.0000.0101 dynamic other FastEthernet6/16
2 0000.0000.0102 dynamic other FastEthernet6/16
2 0000.0000.0103 dynamic other FastEthernet6/16
2 0000.0000.0104 dynamic other FastEthernet6/16
2 0000.0000.0105 dynamic other FastEthernet6/16
2 0000.0000.0106 dynamic other FastEthernet6/16
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
2 ffff.ffff.ffff system Fa6/16
Related Commands
show mac-address-table address
show mac-address-table aging-time
show mac-address-table count
show mac-address-table dynamic
show mac-address-table multicast
show mac-address-table protocol
show mac-address-table static
show mac-address-table vlan
show mac-address-table multicast
To display information about the multicast MAC address table, use the show mac-address-table multicast command.
show mac-address-table multicast [count | {igmp-snooping [count]} | {user [count]} |
{vlan vlan_num}]
Syntax Description
count |
(Optional) Displays the number of multicast entries. |
igmp-snooping |
(Optional) Displays only the addresses learned by IGMP snooping. |
user |
(Optional) Displays only the user-entered static addresses. |
vlan vlan_num |
(Optional) Displays information for a specific VLAN only; valid values are from 1 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
Usage Guidelines
For the MAC address table entries that are used by the routed ports, the routed port name is displayed in the "vlan" column not the the internal VLAN number.
Examples
This example shows how to display multicast MAC address table information for a specific VLAN:
Switch# show mac-address-table multicast vlan 1
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
1 ffff.ffff.ffff system Switch,Fa6/15
This example shows how to display the number of multicast MAC entries for all VLANs:
Switch#
show mac-address-table multicast count
MAC Entries for all vlans:
Multicast MAC Address Count: 141
Total Multicast MAC Addresses Available: 16384
Related Commands
show mac-address-table address
show mac-address-table aging-time
show mac-address-table count
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table protocol
show mac-address-table static
show mac-address-table vlan
show mac-address-table protocol
To display the MAC address table information that is based on the protocol, use the show mac-address-table protocol command.
show mac-address-table protocol {assigned | ip | ipx | other}
Syntax Description
assigned |
Specifies the assigned protocol entries. |
ip |
Specifies the IP protocol entries. |
ipx |
Specifies the IPX protocol entries. |
other |
Specifies the other protocol entries. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
For the MAC address table entries that are used by the routed ports, the routed port name is displayed in the "vlan" column not the the internal VLAN number.
Examples
This example shows how to display the MAC address table entries that have a specific protocol type (in this case, assigned):
Switch#
show mac-address-table protocol assigned
vlan mac address type protocol qos ports
-----+---------------+--------+---------+---+--------------------------------
200 0050.3e8d.6400 static assigned -- Switch
100 0050.3e8d.6400 static assigned -- Switch
5 0050.3e8d.6400 static assigned -- Switch
4092 0000.0000.0000 dynamic assigned -- Switch
1 0050.3e8d.6400 static assigned -- Switch
4 0050.3e8d.6400 static assigned -- Switch
4092 0050.f0ac.3058 static assigned -- Switch
4092 0050.f0ac.3059 dynamic assigned -- Switch
1 0010.7b3b.0978 dynamic assigned -- Fa5/9
This example shows the other output for the previous example:
Switch# show mac-address-table protocol other
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0000.0000.0201 dynamic other FastEthernet6/15
1 0000.0000.0202 dynamic other FastEthernet6/15
1 0000.0000.0203 dynamic other FastEthernet6/15
1 0000.0000.0204 dynamic other FastEthernet6/15
1 0030.94fc.0dff static ip,ipx,assigned,other Switch
2 0000.0000.0101 dynamic other FastEthernet6/16
2 0000.0000.0102 dynamic other FastEthernet6/16
2 0000.0000.0103 dynamic other FastEthernet6/16
2 0000.0000.0104 dynamic other FastEthernet6/16
Fa6/1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/2 0030.94fc.0dff static ip,ipx,assigned,other Switch
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
1 ffff.ffff.ffff system Switch,Fa6/15
2 ffff.ffff.ffff system Fa6/16
1002 ffff.ffff.ffff system
1003 ffff.ffff.ffff system
1004 ffff.ffff.ffff system
1005 ffff.ffff.ffff system
Fa6/1 ffff.ffff.ffff system Switch,Fa6/1
Fa6/2 ffff.ffff.ffff system Switch,Fa6/2
Related Commands
show mac-address-table address
show mac-address-table aging-time
show mac-address-table count
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table multicast
show mac-address-table static
show mac-address-table vlan
show mac-address-table static
To display the static MAC address table entries only, use the show mac-address-table static command.
show mac-address-table static [address mac_addr | interface type number | protocol protocol | vlan vlan_id]
Syntax Description
address mac_addr |
(Optional) Specifies a 48-bit MAC address to match; the valid format is H.H.H. |
interface type number |
(Optional) Specifies an interface to match; valid values for type are fastethernet, gigabitethernet, and tengigabitethernet. |
protocol protocol |
(Optional) Specifies a protocol. See the "Usage Guidelines" section for more information. |
vlan vlan_id |
(Optional) Displays the entries for a specific VLAN; valid values are from 1 to 4094. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
12.2(25)EW |
Added support for the 10-Gigabit Ethernet interface. |
Usage Guidelines
For the MAC address table entries that are used by the routed ports, the routed port name is displayed in the "vlan" column not the internal VLAN number.
The keyword definitions for the protocol argument are as follows:
•
assigned specifies the assigned protocol entries.
•
ip specifies the IP protocol.
•
ipx specifies the IPX protocols.
•
other specifies the other protocol entries.
Examples
This example shows how to display all the static MAC address entries:
Switch#
show mac-address-table static
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/2 0030.94fc.0dff static ip,ipx,assigned,other Switch
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
1 ffff.ffff.ffff system Switch,Fa6/15
2 ffff.ffff.ffff system Fa6/16
1002 ffff.ffff.ffff system
1003 ffff.ffff.ffff system
1004 ffff.ffff.ffff system
1005 ffff.ffff.ffff system
Fa6/1 ffff.ffff.ffff system Switch,Fa6/1
Fa6/2 ffff.ffff.ffff system Switch,Fa6/2
This example shows how to display the static MAC address entries with a specific protocol type (in this case, assigned):
Switch# show mac-address-table static protocol assigned
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/1 0030.94fc.0dff static ip,ipx,assigned,other Switch
Fa6/2 0030.94fc.0dff static ip,ipx,assigned,other Switch
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
1 ffff.ffff.ffff system Switch,Fa6/15
2 ffff.ffff.ffff system Fa6/16
1002 ffff.ffff.ffff system
1003 ffff.ffff.ffff system
1004 ffff.ffff.ffff system
1005 ffff.ffff.ffff system
Fa6/1 ffff.ffff.ffff system Switch,Fa6/1
Fa6/2 ffff.ffff.ffff system Switch,Fa6/2
Related Commands
show mac-address-table address
show mac-address-table aging-time
show mac-address-table count
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table multicast
show mac-address-table protocol
show mac-address-table vlan
show mac-address-table vlan
To display information about the MAC address table for a specific VLAN, use the show mac-address-table vlan command.
show mac-address-table [vlan vlan_id] [protocol protocol]
Syntax Description
vlan vlan_id |
(Optional) Displays the entries for a specific VLAN; valid values are from 1 to 4094. |
protocol protocol |
(Optional) Specifies a protocol. See the "Usage Guidelines" section for more information. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Support for extended addressing was added. |
Usage Guidelines
For the MAC address table entries used by the routed ports, the routed port name is displayed in the "vlan" column not the the internal VLAN number.
The keyword definitions for the protocol variable are as follows:
•
assigned specifies the assigned protocol entries.
•
ip specifies the IP protocol.
•
ipx specifies the IPX protocols.
•
other specifies the other protocol entries.
Examples
This example shows how to display information about the MAC address table for a specific VLAN:
Switch#
show mac-address-table vlan 1
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0000.0000.0201 dynamic ip FastEthernet6/15
1 0000.0000.0202 dynamic ip FastEthernet6/15
1 0000.0000.0203 dynamic other FastEthernet6/15
1 0000.0000.0204 dynamic other FastEthernet6/15
1 0030.94fc.0dff static ip,ipx,assigned,other Switch
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
1 ffff.ffff.ffff system Switch,Fa6/15
This example shows how to display MAC address table information for a specific protocol type:
Switch#
show mac-address-table vlan 100 protocol other
vlan mac address type protocols port
-------+---------------+--------+---------------------+--------------------
1 0000.0000.0203 dynamic other FastEthernet6/15
1 0000.0000.0204 dynamic other FastEthernet6/15
1 0030.94fc.0dff static ip,ipx,assigned,other Switch
vlan mac address type ports
-------+---------------+-------+-------------------------------------------
1 ffff.ffff.ffff system Switch,Fa6/15
Related Commands
show mac-address-table address
show mac-address-table aging-time
show mac-address-table count
show mac-address-table dynamic
show mac-address-table interface
show mac-address-table multicast
show mac-address-table protocol
show mac-address-table static
show module
To display information about the module, use the show module command.
show module [mod | all]
Syntax Description
mod |
(Optional) Number of the module; valid values vary from chassis to chassis. |
all |
(Optional) Displays information for all modules. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)EW |
Enhanced the output of the show idprom interface command to include the 10-Gigabit Ethernet interface. |
Usage Guidelines
In the Mod Sub-Module fields in the command output, the show module command displays the supervisor engine number but appends the uplink daughter card's module type and information.
If the PoE consumed by the module is more than 50 W above the administratively allocated PoE, the "Status" displays as "PwrOver." If the PoE consumed by the module is more than 50 W above the PoE module limit, the "Status" displays as "PwrFault."
Examples
This example shows how to display information for all the modules.
This example shows the show module command output for a system with inadequate power for all installed modules. The system does not have enough power for Module 5; the "Status" displays it as "PwrDeny."
Mod Ports Card Type Model Serial No.
----+-----+--------------------------------------+-----------------+-----------
1 2 1000BaseX (GBIC) Supervisor(active) WS-X4014 JAB054109GH
2 6 1000BaseX (GBIC) WS-X4306 00000110
3 18 1000BaseX (GBIC) WS-X4418 JAB025104WK
5 0 Not enough power for module WS-X4148-FX-MT 00000000000
6 48 10/100BaseTX (RJ45) WS-X4148 JAB023402RP
M MAC addresses Hw Fw Sw Status
--+--------------------------------+---+------------+----------------+---------
1 005c.9d1a.f9d0 to 005c.9d1a.f9df 0.5 12.1(11br)EW 12.1(20020313:00 Ok
2 0010.7bab.9920 to 0010.7bab.9925 0.2 Ok
3 0050.7356.2b36 to 0050.7356.2b47 1.0 Ok
5 0001.64fe.a930 to 0001.64fe.a95f 0.0 PwrDeny
6 0050.0f10.28b0 to 0050.0f10.28df 1.0 Ok
This example shows how to display information for a specific module:
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
2 2 Catalyst 4000 supervisor 2 (Active) WS-X6K-SUP2-2GE SAD04450LF1
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
2 0001.6461.39c0 to 0001.6461.39c1 1.1 6.1(3) 6.2(0.97) Ok
Mod Sub-Module Model Serial Hw Status
--- --------------------------- --------------- --------------- ------- -------
2 Policy Feature Card 2 WS-F6K-PFC2 SAD04440HVU 1.0 Ok
2 Cat4k MSFC 2 daughterboard WS-F6K-MSFC2 SAD04430J9K 1.1 Ok
This example shows how to display information for all the modules on the switch:
Power consumed by backplane : 0 Watts
Mod Ports Card Type Model Serial No.
---+-----+--------------------------------------+------------------+-----------
1 6 XG (X2), 1000BaseX (SFP) Supervisor(ac WS-X4517 ""
3 6 1000BaseX (GBIC) WS-X4306 00000110
M MAC addresses Hw Fw Sw Status
--+--------------------------------+---+------------+----------------+---------
1 0004.dd46.7700 to 0004.dd46.7705 0.0 12.2(20r)EW( 12.2(20040513:16 Ok
3 0010.7bab.9920 to 0010.7bab.9925 0.2 Ok
show monitor
To display information about the SPAN session, use the show monitor command.
show monitor [session] [range session-range | local | remote | all | session-number] [detail]
Syntax Description
session |
(Optional) Displays the SPAN information for a session. |
range |
(Optional) Displays information for a range of sessions. |
session-range |
(Optional) Specifies a range of sessions. |
local |
(Optional) Displays all local SPAN sessions. |
remote |
(Optional) Displays the RSPAN source and destination sessions. |
all |
(Optional) Displays the SPAN and RSPAN sessions. |
session-number |
(Optional) Session number; valid values are from1 to 6. |
detail |
(Optional) Displays the detailed SPAN information for a session. |
Defaults
The detail keyword only displays lines with a nondefault configuration.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(13)EW |
Added support for differing directions within a single user session. |
12.1(19)EW |
Output enhanced to display configuration status of SPAN enhancements. |
12.1(20)EW |
Added support to display configuration state for remote SPAN and learning. |
12.2(20)EW |
Added support to display ACLs that are applied to SPAN sessions. |
Examples
This example shows how to display whether ACLs are applied to a given SPAN session on a Catalyst 4500 series switch:
Destination Ports : Fa6/2
This example shows how to display SPAN information for session 2:
Switch# show monitor session 2
Type : Remote Source Session
Ingress : Enabled, default VLAN=2
This example shows how to display the detailed SPAN information for session 1:
Switch#
show monitor session 1 detail
Source RSPAN VLAN : Fa6/1
Destination Ports : Fa6/1
Ingress : Enabled, default VLAN = 2
Ingress : Enabled, default VLAN=2
This example shows how to display SPAN information for session 1 beginning with the line that starts with Destination:
Switch#
show monitor session 1 | begin Destination
Related Commands
monitor session
show pagp
To display information about the port channel, use the show pagp command.
show pagp [group-number] {counters | internal | neighbor}
Syntax Description
group-number |
(Optional) Channel-group number; valid values are from 1 to 64. |
counters |
Specifies the traffic counter information. |
internal |
Specifies the PAgP internal information. |
neighbor |
Specifies the PAgP neighbor information. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
You can enter any show pagp command to display the active PAgP port-channel information. To display the nonactive information, enter the show pagp command with a group.
Examples
This example shows how to display information about the PAgP counter:
Switch#
show pagp counters
--------------------------------------
This example shows how to display internal PAgP information:
Switch# show pagp 1 internal
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
Hello Partner PAgP Learning
Port Flags State Timers Interval Count Priority Method IfIndx
Fa5/4 SC U6/S7 30s 1 128 Any 129
Fa5/5 SC U6/S7 30s 1 128 Any 129
This example shows how to display PAgP neighbor information for all neighbors:
Switch# show pagp neighbor
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Channel group 1 neighbors
Partner Partner Partner Partner Group
Port Name Device ID Port Age Flags Cap.
Fa5/4 JAB031301 0050.0f10.230c 2/45 2s SAC 2D
Fa5/5 JAB031301 0050.0f10.230c 2/46 27s SAC 2D
Channel group 2 neighbors
Partner Partner Partner Partner Group
Port Name Device ID Port Age Flags Cap.
Fa5/6 JAB031301 0050.0f10.230c 2/47 10s SAC 2F
Fa5/7 JAB031301 0050.0f10.230c 2/48 11s SAC 2F
Related Commands
pagp learn-method
pagp port-priority
show policy-map
To display information about the policy map, use the show policy-map command.
show policy-map [policy_map_name]
Syntax Description
policy_map_name |
(Optional) Name of the policy map. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display information for all the policy maps:
This example shows how to display information for a specific policy map:
Switch# show policy ipp5-policy
Related Commands
class-map
policy-map
show class-map
show policy-map interface
show policy-map interface
To display the statistics and configurations of the input and output policies that are attached to an interface, use the show policy-map interface command.
show policy-map interface [{fastethernet interface-number} | {gigabitethernet interface-number} | {port-channel number} | {vlan vlan_id}] [input | output]
Syntax Description
fastethernet interface-number |
(Optional) Specifies the Fast Ethernet 802.3 interface. |
gigabitethernet interface-number |
(Optional) Specifies the Gigabit Ethernet 802.3z interface. |
port-channel number |
(Optional) Specifies the port channel. |
vlan vlan_id |
(Optional) Specifies the VLAN ID; valid values are from 1 to 4094. |
input |
(Optional) Specifies input policies only. |
output |
(Optional) Specifies output policies only. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(12c)EW |
Added support for extended VLAN addresses. |
12.2(25)SG |
Displays results for full flow policing. |
Examples
This example shows how to display the statistics and configurations of all input and output policies attached to an interface:
Switch# show policy-map interface
service-policy input:ipp5-policy
class-map:ipp5 (match-all)
class-map:class-default (match-any)
service-policy output:ipp5-policy
class-map:ipp5 (match-all)
class-map:class-default (match-any)
This example shows how to display the input policy statistics and configurations for a specific interface:
Switch# show policy-map interface fastethernet 5/36 input
service-policy input:ipp5-policy
class-map:ipp5 (match-all)
class-map:class-default (match-any)
With the following configuration, each flow is policed to a 1000000 bps with an allowed 9000-byte burst value.
Note
If you use the match flow ip source-address|destination-address command, these two flows are consolidated into one flow and they have the same source and destination address.
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)# class-map c1
Switch(config-cmap)# match flow ip source-address ip destination-address ip protocol l4
source-port l4 destination-port
Switch(config-cmap)# exit
Switch(config)# policy-map p1
Switch(config-pmap)# class c1
Switch(config-pmap-c)# police 1000000 9000
Switch(config-pmap-c)# exit
Switch(config-pmap)# exit
Switch(config)# interface fastEthernet 6/1
Switch(config-if)# service-policy input p1
Switch# show policy-map interface
match flow ip source-address ip destination-address ip protocol l4 source-port l4
destination-port
police 1000000 bps 9000 byte conform-action transmit exceed-action drop
interface FastEthernet 6/1
Switch# show policy-map p1
police 1000000 bps 9000 byte conform-action transmit exceed-action drop
Switch# show policy-map interface
Class-map: c1 (match-all)
Match: flow ip source-address ip destination-address ip protocol l4 source-port l4
destination-port
Conform: 64995654 bytes Exceed: 2376965424 bytes
Class-map: class-default (match-any)
Related Commands
class-map
policy-map
show class-map
show qos
show policy-map interface vlan
To show the QoS policy-map information applied to a specific VLAN on an interface, use the
show policy-map interface vlan command.
show policy-map interface vlan interface-id vlan vlan-id
Syntax Description
interface interface-id |
(Optional) Displays QoS policy-map information for a specific interface. |
vlan vlan-id |
(Optional) Displays QoS policy-map information for a specific VLAN. |
Command Modes
Privileged EXEC
Command History
|
|
12.1(13)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
Take the following configuration as an example:
interface GigabitEthernet3/1
This example shows how to display policy-map statistics on VLAN 20 on the Gigabit Ethernet 6/1 interface:
Switch# show policy-map interface gigabitEthernet 3/1 vlan 20
GigabitEthernet3/1 vlan 20
Class-map: class-default (match-any)
Conform: 0 bytes Exceed: 0 bytes
Related Commands
service-policy
show policy-map interface
show port-security
To display the port security settings for an interface or for the switch, use the show port-security command.
show port-security [address] [interface interface-id] [vlan vlan-id]
Syntax Description
address |
(Optional) Displays all secure MAC addresses for all ports or for a specific port. |
interface interface-id |
(Optional) Displays port security settings for a specific interface. |
vlan vlan-id |
(Optional) Displays port security settings for a specific VLAN. |
Command Modes
Privileged EXEC
Command History
|
|
12.1(13)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(18)EW |
Support was enhanced to display sticky MAC addresses. |
12.2(25)EWA |
Support was enhanced to display setting on a per-VLAN basis. |
Usage Guidelines
If you enter the command without keywords, the output includes the administrative and operational status of all secure ports on the switch.
If you enter the interface-id value, the show port-security command displays port security settings for the interface.
If you enter the address keyword, the show port-security address command displays the secure MAC addresses for all interfaces and the aging information for each secure address.
If you enter the interface-id value and the address keyword, the show port-security address interface command displays all the MAC addresses for the interface with aging information for each secure address. You can also use this command to display all the MAC addresses for an interface even if you have not enabled port security on it.
Examples
This example shows how to display port security settings for the entire switch:
Switch# show port-security
Secure Port MaxSecureAddr CurrentAddr SecurityViolation Security Action
---------------------------------------------------------------------------
---------------------------------------------------------------------------
Total Addresses in System (excluding one mac per port) :8
Max Addresses limit in System (excluding one mac per port) :1024
Global SNMP trap control for port-security :20 (traps per second)
This example shows how to display port security settings for interface Fast Ethernet 5/1:
Switch# show port-security interface fastethernet 5/1
Violation Mode : Shutdown
SecureStatic Address Aging : Disabled
Maximum MAC Addresses : 1
Configured MAC Addresses : 0
Last Source Address : 0000.0001.001a
Security Violation Count : 0
This example shows how to display all secure MAC addresses configured on all switch interfaces:
Switch# show port-security address
-------------------------------------------------------------------
Vlan Mac Address Type Ports Remaining Age
---- ----------- ---- ----- -------------
1 0000.0001.0000 SecureConfigured Fa3/1 15 (I)
1 0000.0001.0001 SecureConfigured Fa3/1 14 (I)
1 0000.0001.0100 SecureConfigured Fa3/2 -
1 0000.0001.0101 SecureConfigured Fa3/2 -
1 0000.0001.0200 SecureConfigured Fa3/3 -
1 0000.0001.0201 SecureConfigured Fa3/3 -
1 0000.0001.0300 SecureConfigured Fa3/4 -
1 0000.0001.0301 SecureConfigured Fa3/4 -
1 0000.0001.1000 SecureDynamic Fa3/5 -
1 0000.0001.1001 SecureDynamic Fa3/5 -
1 0000.0001.1100 SecureDynamic Fa3/6 -
1 0000.0001.1101 SecureDynamic Fa3/6 -
1 0000.0001.1200 SecureSticky Fa3/7 -
1 0000.0001.1201 SecureSticky Fa3/7 -
1 0000.0001.1300 SecureSticky Fa3/8 -
1 0000.0001.1301 SecureSticky Fa3/8 -
-------------------------------------------------------------------
Total Addresses in System (excluding one mac per port) :8
Max Addresses limit in System (excluding one mac per port) :3072
This example shows how to display the maximum allowed number of secure MAC addresses and the current number of secure MAC addresses on interface Gigabitethernet1/1:
Switch# show port-security interface gigabitethernet1/1 vlan
This example shows how to display the port security settings on interface Gigabitethernet1/1 for VLANs 2 and 3:
Switch# show port-security interface gigabitethernet1/1 vlan 2-3
This example shows how to display all secure MAC addresses configured on interface Gigabitethernet1/1 with aging information for each address.
Switch# show port-security interface gigabitethernet1/1 address
------------------------------------------------------------------------
Vlan Mac Address Type Ports Remaining Age(mins)
---- ----------- ---- ----- -------------
2 0001.0001.0001 SecureConfigured Gi1/1 -
2 0001.0001.0002 SecureSticky Gi1/1 -
3 0001.0001.0001 SecureConfigured Gi1/1 -
3 0001.0001.0002 SecureSticky Gi1/1 -
3 0001.0001.0003 SecureSticky Gi1/1 -
4 0001.0001.0001 SecureConfigured Gi1/1 -
4 0001.0001.0003 SecureSticky Gi1/1 -
6 0001.0001.0001 SecureConfigured Gi1/1 -
6 0001.0001.0002 SecureConfigured Gi1/1 -
------------------------------------------------------------------------
This example shows how to display all secure MAC addresses configured on VLANs 2 and 3 on interface Gigabitethernet1/1 with aging information for each address:
Switch# show port-security interface gigabitethernet1/1 address vlan 2-3
------------------------------------------------------------------------
Vlan Mac Address Type Ports Remaining Age(mins)
---- ----------- ---- ----- -------------
2 0001.0001.0001 SecureConfigured Gi1/1 -
2 0001.0001.0002 SecureSticky Gi1/1 -
2 0001.0001.0003 SecureSticky Gi1/1 -
3 0001.0001.0001 SecureConfigured Gi1/1 -
3 0001.0001.0002 SecureSticky Gi1/1 -
3 0001.0001.0003 SecureSticky Gi1/1 -
------------------------------------------------------------------------
Related Commands
switchport port-security
show power
To display information about the power status, use the show power command.
show power [available | capabilities | detail | inline {[interface] | consumption default | module mod} | module | status | supplies]
Syntax Description
available |
(Optional) Displays the available system power. |
capabilities |
(Optional) Displays the individual power supply capabilities. |
detail |
(Optional) Displays detailed information on power resources. |
inline |
(Optional) Displays the PoE status. |
interface |
(Optional) Type of interface; the only valid value is fastethernet. |
consumption default |
(Optional ) Displays the PoE consumption. |
module mod |
(Optional) Displays the PoE consumption for the specified module. |
module |
(Optional) Displays the power consumption for each module. |
status |
(Optional) Displays the power supply status. |
supplies |
(Optional) Displays the number of power supplies needed by the system. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.2(25)SG |
Displays inline power handling for the Supervisor Engine II-TS. |
Usage Guidelines
If a powered device is connected to an interface with external power, the switch does not recognize the powered device. The Device column in the output of the show power inline command displays as unknown.
If your port is not capable of supporting Power over Ethernet, you will receive this message:
Power over Ethernet not supported on interface Admin
The show power in-line interface | module command displays the amount of power that is used to operate a Cisco 7960 IP Phone. To view the amount of power requested, use the show cdp neighbors command.
Because of the PoE consumed by FPGAs and other hardware components on the module the operating PoE consumption for an 802.3af-compliant module can be nonzero, even when there are no powered devices attached to the module. The operating PoE can vary by as much as 20 W because of fluctuations in the PoE that is consumed by the hardware components.
Examples
This example shows how to display information about the general power supply:
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------ ------
PS1 PWR-C45-2800AC AC 2800W good good good
PS2 PWR-C45-1000AC AC 1000W err-disable good n.a.
*** Power Supplies of different type have been detected***
Power supplies needed by system :1
Power supplies currently available :1
(in Watts) Used Available
---------------------- ---- ---------
System Power (12V) 328 1360
Inline Power (-50V) 0 1400
Backplane Power (3.3V) 10 40
---------------------- ----
Total Used 338 (not to exceed Total Maximum Available = 750)
This example shows how to display the amount of available system power:
Switch#
show power available
(in Watts) Available Used Remaining
------------- --------- ------ ---------
System Power 1360 280 1080
Maximum Power 2800 280 2520
This example shows how to display detailed information for system power.
Switch# show power detail
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-1400DC DCSP1400W good good n.a.
Power supplies needed by system : 1
Power supplies currently available : 1
(in Watts) Used Available
---------------------- ---- ---------
System Power (12V) 360 360
Backplane Power (3.3V) 0 40
---------------------- ---- ---------
Module Inline Power Summary (Watts)
(12V -> -48V on board conversion)
---------------------------------
Watts Used of System Power (12V)
Mod Model currently out of reset in reset
---- ----------------- --------- ------------ --------
1 WS-X4013+TS 180 180 180
3 WS-X4424-GB-RJ45 90 90 50
----------------------- --------- ------------ -------
Watts used of Chassis Inline Power (-50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
2 WS-X4506-GB-T 0 0 0 0 89
3 WS-X4424-GB-RJ45 - - - - -
----------------------- ---------------- ---------------- ----------
Watts used of Module Inline Power (12V -> -50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
----------------------- ---------------- ---------------- ----------
This example shows how to display power consumption for the module.
Switch# show power module
Watts Used of System Power (12V)
Mod Model currently out of reset in reset
---- ----------------- --------- ------------ --------
1 WS-X4013+TS 180 180 180
3 WS-X4424-GB-RJ45 90 90 50
----------------------- --------- ------------ -------
Watts used of Chassis Inline Power (-50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
2 WS-X4506-GB-T 0 0 0 0 89
3 WS-X4424-GB-RJ45 - - - - -
----------------------- ---------------- ---------------- ----------
Watts used of Module Inline Power (12V -> -50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
----------------------- ---------------- ---------------- ----------
Note
The "Inline Power Oper" column displays the PoE consumed by the powered devices attached to the module in addition to the PoE consumed by the FPGAs and other hardware components on the module. The "Inline Power Admin" column displays only the PoE allocated by the powered devices attached to the module.
This example shows how to display the power status information:
Switch# show power status
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------ ------
PS1 PWR-C45-2800AC AC 2800W good good good
PS2 PWR-C45-2800AC AC 2800W good good good
Power Supply Max Min Max Min Absolute
(Nos in Watts) Inline Inline System System Maximum
-------------- ------ ------ ------ ------ --------
PS1 1400 1400 1360 1360 2800
PS2 1400 1400 1360 1360 2800
This example shows how to verify the PoE consumption for the switch:
Switch# show power inline consumption default
Default PD consumption : 5000 mW
This example shows how to display the status of inline power:
Switch# show power inline
Available:677(w) Used:117(w) Remaining:560(w)
Interface Admin Oper Power(Watts) Device Class
--------- ------ ---------- ---------- ---------- ------------------- -----
Fa3/1 auto on 17.3 15.4 Ieee PD 0
Fa3/2 auto on 4.5 4.0 Ieee PD 1
Fa3/3 auto on 7.1 6.3 Cisco IP Phone 7960 0
Fa3/4 auto on 7.1 6.3 Cisco IP Phone 7960 n/a
Fa3/5 auto on 17.3 15.4 Ieee PD 0
Fa3/6 auto on 17.3 15.4 Ieee PD 0
Fa3/7 auto on 4.5 4.0 Ieee PD 1
Fa3/8 auto on 7.9 7.0 Ieee PD 2
Fa3/9 auto on 17.3 15.4 Ieee PD 3
Fa3/10 auto on 17.3 15.4 Ieee PD 4
Fa3/11 auto off 0 0 n/a n/a
Fa3/12 auto off 0 0 n/a n/a
Fa3/13 auto off 0 0 n/a n/a
Fa3/14 auto off 0 0 n/a n/a
Fa3/15 auto off 0 0 n/a n/a
Fa3/16 auto off 0 0 n/a n/a
Fa3/17 auto off 0 0 n/a n/a
Fa3/18 auto off 0 0 n/a n/a
--------- ------ ---------- ---------- ---------- ------------------- -----
Totals: 10 on 117.5 104.6
This example shows how to display the number of power supplies needed by the system:
Switch#
show power supplies
Power supplies needed by system = 2
This example shows how to display the PoE status for Fast Ethernet interface 3/1:
Switch# show power inline fastethernet3/1
Available:677(w) Used:11(w) Remaining:666(w)
Interface Admin Oper Power(Watts) Device Class
--------- ------ ---------- ---------- ---------- ------------------- -----
Fa3/1 auto on 11.2 10.0 Ieee PD 0
Interface AdminPowerMax AdminConsumption
---------- --------------- --------------------
Note
When the Supervisor Engine II+TS is used with the 1400 W DC power supply (PWR-C45-1400DC), and only one 12.5 A input of the DC power supply is used, the supervisor engine's power consumption may vary depending on whether there is any linecard inserted at slot 2 and 3, as well as on the type of linecards inserted. This amount varies between 155 W and 330 W. This variability also affects the maximum amount of available supervisor engine inline power, which can also vary from 0 W to 175 W. Therefore, it is possible for a supervisor engine to deny inline power to some connected inline power devices when one or more linecards are inserted into the chassis.
The output of the commands show power detail and show power module display the supervisor engine's variable power consumption and its inline power summary.
Switch# show power detail
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C45-1400DC DCSP1400W good good n.a.
Power supplies needed by system : 1
Power supplies currently available : 1
(in Watts) Used Available
---------------------- ---- ---------
System Power (12V) 360 360
Backplane Power (3.3V) 0 40
---------------------- ---- ---------
Module Inline Power Summary (Watts)
(12V -> -48V on board conversion)
---------------------------------
Watts Used of System Power (12V)
Mod Model currently out of reset in reset
---- ----------------- --------- ------------ --------
1 WS-X4013+TS 180 180 180
3 WS-X4424-GB-RJ45 90 90 50
----------------------- --------- ------------ -------
Watts used of Chassis Inline Power (-50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
2 WS-X4506-GB-T 0 0 0 0 89
3 WS-X4424-GB-RJ45 - - - - -
----------------------- ---------------- ---------------- ----------
Watts used of Module Inline Power (12V -> -50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
----------------------- ---------------- ---------------- ----------
Watts Used of System Power (12V)
Mod Model currently out of reset in reset
---- ----------------- --------- ------------ --------
1 WS-X4013+TS 180 180 180
3 WS-X4424-GB-RJ45 90 90 50
----------------------- --------- ------------ -------
Watts used of Chassis Inline Power (-50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
2 WS-X4506-GB-T 0 0 0 0 89
3 WS-X4424-GB-RJ45 - - - - -
----------------------- ---------------- ---------------- ----------
Watts used of Module Inline Power (12V -> -50V)
Inline Power Admin Inline Power Oper
Mod Model PS Device PS Device Efficiency
---- ----------------- ---------------- ---------------- ----------
----------------------- ---------------- ---------------- ----------
Related Commands
power dc input
power inline
power inline consumption
power redundancy-mode
power supplies required
show qos
To display QoS information, use the show qos command.
show qos
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows the output that might be displayed if you do not enter any keywords:
Related Commands
qos (global configuration mode)
qos (interface configuration mode)
show qos aggregate policer
To display QoS aggregate policer information, use the show qos aggregate policer command.
show qos aggregate policer [aggregate_name]
Syntax Description
aggregate_name |
(Optional) Named aggregate policer. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Usage Guidelines
The aggregate policer name is case sensitive.
Examples
This example shows the output if you do not enter any keywords:
Switch# show qos aggregate policer
Rate(bps):10000000 Normal-Burst(bytes):1000000
conform-action:transmit exceed-action:policed-dscp-transmit
Policymaps using this policer:
Related Commands
qos aggregate-policer
show qos dbl
To display global Dynamic Buffer Limiting (DBL) information, use the show qos dbl command.
show qos dbl
Syntax Description
This command has no arguments or keywords.
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(13)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display global DBL information:
DBL flow includes l4-ports
DBL does not use ecn to indicate congestion
DBL exceed-action mark probability:15%
DBL aggressive credit limit:10
DBL aggressive buffer limit:2 packets
Related Commands
qos (global configuration mode)
qos dbl
show qos interface
To display queueing information, use the show qos interface command.
show qos interface {fastethernet interface-number | gigabitethernet interface-number} |
[vlan vlan_id | port-channel number]
Syntax Description
fastethernet interface-number |
Specifies the Fast Ethernet 802.3 interface. |
gigabitethernet interface-number |
Specifies the Gigabit Ethernet 802.3z interface. |
vlan vlan_id |
(Optional) Specifies the VLAN ID; valid values are from 1 to 4094. |
port-channel number |
(Optional) Specifies the port channel; valid ranges are from 1 to 64. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
12.1(13)EW |
Added support for extended VLAN addresses. |
12.1(19)EW |
Display changed to include the Port Trust Device. |
Examples
This example shows how to display queueing information:
Switch# show qos interface fastethernet 6/1
Administrative Port Trust State: `dscp'
Operational Port Trust State: `untrusted'
Port Trust Device:'cisco-phone'
Default DSCP:0 Default CoS:0
Tx-Queue Bandwidth ShapeRate Priority QueueSize
1 31250000 disabled N/A 240
2 31250000 disabled N/A 240
3 31250000 disabled normal 240
4 31250000 disabled N/A 240
Related Commands
qos map cos
show qos
tx-queue
show qos maps
To display QoS map information, use the show qos maps command.
show qos maps [cos | dscp [policed | tx-queue]]
Syntax Description
cos |
(Optional) Displays CoS map information. |
dscp |
(Optional) Displays DSCP map information. |
policed |
(Optional) Displays policed map information. |
tx-queue |
(Optional) Displays tx-queue map information. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1(8a)EW |
Support for this command was introduced on the Catalyst 4500 series switch. |
Examples
This example shows how to display QoS map settings:
DSCP-TxQueue Mapping Table (dscp = d1d2)
d1 :d2 0 1 2 3 4 5 6 7 8 9
-------------------------------------
0 : 01 01 01 01 01 01 01 01 01 01
1 : 01 01 01 01 01 01 02 02 02 02
2 : 02 02 02 02 02 02 02 02 02 02
3 : 02 02 03 03 03 03 03 03 03 03
4 : 03 03 03 03 03 03 03 03 04 04
5 : 04 04 04 04 04 04 04 04 04 04
Policed DSCP Mapping Table (dscp = d1d2)
d1 :d2 0 1 2 3 4 5 6 7 8 9
-------------------------------------
0 : 00 01 02 03 04 05 06 07 08 09
1 : 10 11 12 13 14 15 16 17 18 19
2 : 20 21 22 23 24 25 26 27 28 29
3 : 30 31 32 33 34 35 36 37 38 39
4 : 40 41 42 43 44 45 46 47 48 49
5 : 50 51 52 53 54 55 56 57 58 59
DSCP-CoS Mapping Table (dscp = d1d2)
d1 :d2 0 1 2 3 4 5 6 7 8 9
-------------------------------------
0 : 00 00 00 00 00 00 00 00 01 01
1 : 01 01 01 01 01 01 02 02 02 02
2 : 02 02 02 02 03 03 03 03 03 03
3 : 03 03 04 04 04 04 04 04 04 04
4 : 05 05 05 05 05 05 05 05 06 06
5 : 06 06 06 06 06 06 07 07 07 07
--------------------------------
DSCP: 0 8 16 24 32 40 48 56
Related Commands
qos (global configuration mode)
qos (interface configuration mode)
show redundancy
To display redundancy facility information, use the show redundancy command.
show redundancy {clients | counters | history | states}
Syntax Description
clients |
(Optional) Displays information about the redundancy facility client. |
counters |
(Optional) Displays information about the redundancy facility counter. |
history |
(Optional) Displays a log of past status and related information for the redundancy facility. |
states |
(Optional) Displays information about the redundancy facility state. |
Defaults
This command has no default settings.
Command Modes
Privileged EXEC
Command History
|
|
12.1.(13)EW |
Support for this command was introduced on the Catalyst 4500 series switch (Catalyst 4507R only). |
Examples
This example shows how to display information about the redundancy facility:
4507r-demo#show redundancy
Redundant System Information :
------------------------------
Available system uptime = 2 days, 2 hours, 39 minutes
Switchovers system experienced = 0
Last switchover reason = none
Configured Redundancy Mode = Stateful Switchover
Operating Redundancy Mode = Stateful Switchover
Maintenance Mode = Disabled
Current Processor Information :
-------------------------------
Current Software state = ACTIVE
Uptime in current state = 2 days, 2 hours, 39 minutes
Image Version = Cisco Internetwork Operating System Software
IOS (tm) Catalyst 4000 L3 Switch Software (cat4000-I5S-M), Version 12.2(20)EWA(3
.92), CISCO INTERNAL USE ONLY ENHANCED PRODUCTION VERSION
Copyright (c) 1986-2004 by cisco Systems, Inc.
Compiled Wed 14-Jul-04 04:42 by esi
BOOT = bootflash:cat4000-i5s-mz.122_20_EWA_392,1
Configuration register = 0x2002
Peer Processor Information :
----------------------------
Standby Location = slot 2
Current Software state = STANDBY HOT
Uptime in current state = 2 days, 2 hours, 39 minutes
Image Version = Cisco Internetwork Operating System Software
IOS (tm) Catalyst 4000 L3 Switch Software (cat4000-I5S-M), Version 12.2(20)EWA(3
.92), CISCO INTERNAL USE ONLY ENHANCED PRODUCTION VERSION
Copyright (c) 1986-2004 by cisco Systems, Inc.