Displaying Information About the Installed Hardware Modules

You can display information about the switch hardware and the hardware modules that are installed in the switch by using the show hardware command.

ASW4_QP_LEM# show hardwareCisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac        
Copyright (C) 2002-2022, Cisco and/or its affiliates.
All rights reserved.                                
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under their own
licenses, such as open source.  This software is provided "as is," and unless
otherwise stated, there is no warranty, express or implied, including but not
limited to warranties of merchantability and fitness for a particular purpose.
Certain components of this software are licensed under                        
the GNU General Public License (GPL) version 2.0 or                          
GNU General Public License (GPL) version 3.0  or the GNU                      
Lesser General Public License (LGPL) Version 2.1 or                          
Lesser General Public License (LGPL) Version 2.0.                            
A copy of each such license is available at                                  
http://www.opensource.org/licenses/gpl-2.0.php and                            
http://opensource.org/licenses/gpl-3.0.html and                              
http://www.opensource.org/licenses/lgpl-2.1.php and                          
http://www.gnu.org/licenses/old-licenses/library.txt.                        

Software
  BIOS: version 01.09
  NXOS: version 10.3(2) [Feature Release]
  Host NXOS: version 10.3(2)            
  BIOS compile time:  09/28/2022        
  NXOS image file is: bootflash:///nxos64-cs.10.3.2.F.bin_24
  NXOS compile time:  11/30/2022 12:00:00 [12/16/2022 04:02:06]
  NXOS boot mode: LXC                                          

Hardware
  cisco Nexus9000 C9408 Chassis
  Intel(R) Xeon(R) CPU D-1633N @ 2.50GHz with 32801260 kB of memory.
  Processor Board ID FDO262208WX                                    
  Device name: ASW4_QP_LEM                                          
  bootflash:  115343360 kB                                          

Kernel uptime is 2 day(s), 22 hour(s), 9 minute(s), 16 second(s)

Last reset at 282926 usecs after 1671239402
  Reason: Reset Requested by CLI command reload
  System version: 10.3(2)                      
  Service:                                    

plugin
  Core Plugin, Ethernet Plugin
--------------------------------
Switch hardware ID information  
--------------------------------

Switch is booted up
  Switch type is : Nexus9000 C9408 Chassis
  Model number is N9K-C9408              
  H/W version is 0.1                      
  Part Number is 73-102375-03            
  Part Revision is 03                    
  Manufacture Date is Year 2022 Week 21  
  Serial number is FDO262100LC            
  CLEI code is 0                          

-------------------------------------
Chassis has 8 Module slots          
-------------------------------------
Module1  ok                          
  Module type is : "Supervisor"      
  0 submodules are present          
  Model number is                    
  H/W version is 0.0                
  Part Number is                    
  Part Revision is                  
  Manufacture Date is Year 1996 Week 0
  Serial number is                    
  CLEI code is                        

LEM-Module1  empty

LEM-Module2  ok
  LEM-Module type is : 8x400G Ethernet Module
  0 submodules are present                  
  Model number is N9K-X9400-8D              
  H/W version is 0.3                        
  Part Number is 73-102376-03                
  Part Revision is 07                        
  Manufacture Date is Year 2022 Week 22      
  Serial number is FDO26221BA7              
  CLEI code is 0                            

LEM-Module3  ok
  LEM-Module type is : 16x200G Ethernet Module
  0 submodules are present                    
  Model number is N9K-X9400-16W              
  H/W version is 0.3                          
  Part Number is 73-102377-03                
  Part Revision is 07                        
  Manufacture Date is Year 2022 Week 22      
  Serial number is FDO262213VA                
  CLEI code is 0                              

LEM-Module4  empty

LEM-Module5  ok
  LEM-Module type is : 8x400G Ethernet Module
  0 submodules are present                  
  Model number is N9K-X9400-8D              
  H/W version is 0.3                        
  Part Number is 73-102376-03                
  Part Revision is 07                        
  Manufacture Date is Year 2022 Week 22      
  Serial number is FDO26221BAK              
  CLEI code is 0                            

LEM-Module6  empty

LEM-Module7  ok
  LEM-Module type is : 16x200G Ethernet Module
  0 submodules are present                    
  Model number is N9K-X9400-16W              
  H/W version is 0.3                          
  Part Number is 73-102377-03                
  Part Revision is 07                        
  Manufacture Date is Year 2022 Week 22      
  Serial number is FDO262213VQ                
  CLEI code is 0                              

LEM-Module8  empty

---------------------------------------
Chassis has 4 PowerSupply Slots        
---------------------------------------

PS1 fail/shutdown
  Power supply type is: 2000.00W 220v AC
  Model number is NXA-PAC-2KW-PI        
  H/W version is 0                      
  Part Number is 341-1888-01            
  Part Revision is A0                  
  Manufacture Date is Year 2021 Week 47
  Serial number is POG2547JACK          
  CLEI code is CMUPAFGCAA              

PS2 fail/shutdown
  Power supply type is: 2000.00W 220v AC
  Model number is NXA-PAC-2KW-PI        
  H/W version is 0                      
  Part Number is 341-1888-01            
  Part Revision is A0                  
  Manufacture Date is Year 2021 Week 47
  Serial number is POG2547JA1Q          
  CLEI code is CMUPAFGCAA              

PS3 fail/shutdown
  Power supply type is: 2000.00W 220v AC
  Model number is NXA-PAC-2KW-PI        
  H/W version is 0
  Part Number is 341-1888-01
  Part Revision is A0
  Manufacture Date is Year 2021 Week 47
  Serial number is POG2547JAH6
  CLEI code is CMUPAFGCAA

PS4 ok
  Power supply type is: 2000.00W 220v AC
  Model number is NXA-PAC-2KW-PI
  H/W version is 0
  Part Number is 341-1888-01
  Part Revision is A0
  Manufacture Date is Year 2021 Week 47
  Serial number is POG2547JA20
  CLEI code is CMUPAFGCAA

----------------------------------
Chassis has 5 Fan slots
----------------------------------

Fan1 ok

Fan2 ok

Fan3 ok

Fan4 ok

Fan5 ok

ASW4_QP_LEM#

Displaying the Hardware Inventory for the Switch

You can display information about the field replaceable units (FRUs), that are installed in the switch by using the show inventory command.

ASW4_QP_LEM# show inventory
NAME: "Chassis",  DESCR: "Nexus9000 C9408 Chassis"              
PID: N9K-C9408           ,  VID: V00 ,  SN: FDO262100LC          

NAME: "Switch Card",  DESCR: "Switch Card"                          
PID: N9K-C9400-SW-GX2A   ,  VID: V00 ,  SN: FDO262200E1              

NAME: "Slot 1",  DESCR: "Supervisor"                            
PID: N9K-C9400-SUP-A     ,  VID: V00 ,  SN: FDO262208WX          

NAME: "Slot 27",  DESCR: "Supervisor"                            
PID: N9K-C9400-SUP-A     ,  VID: V00 ,  SN: FDO262208WX          

NAME: "LEM 2",  DESCR: "8x400G Ethernet Module"                
PID: N9K-X9400-8D        ,  VID: V00 ,  SN: FDO26221BA7          

NAME: "LEM 3",  DESCR: "16x200G Ethernet Module"              
PID: N9K-X9400-16W       ,  VID: V00 ,  SN: FDO262213VA          

NAME: "LEM 5",  DESCR: "8x400G Ethernet Module"                
PID: N9K-X9400-8D        ,  VID: V00 ,  SN: FDO26221BAK          

NAME: "LEM 7",  DESCR: "16x200G Ethernet Module"
PID: N9K-X9400-16W       ,  VID: V00 ,  SN: FDO262213VQ

NAME: "Power Supply 1",  DESCR: "Nexus9000 C9408 Chassis Power Supply"
PID: NXA-PAC-2KW-PI      ,  VID: V01 ,  SN: POG2547JACK

NAME: "Power Supply 2",  DESCR: "Nexus9000 C9408 Chassis Power Supply"
PID: NXA-PAC-2KW-PI      ,  VID: V01 ,  SN: POG2547JA1Q

NAME: "Power Supply 3",  DESCR: "Nexus9000 C9408 Chassis Power Supply"
PID: NXA-PAC-2KW-PI      ,  VID: V01 ,  SN: POG2547JAH6

NAME: "Power Supply 4",  DESCR: "Nexus9000 C9408 Chassis Power Supply"
PID: NXA-PAC-2KW-PI      ,  VID: V01 ,  SN: POG2547JA20

NAME: "Fan 1",  DESCR: "Nexus9000 C9408 Chassis Fan Module"
PID: N9K-C9400-FAN-PI    ,  VID: V01 ,  SN: N/A

NAME: "Fan 2",  DESCR: "Nexus9000 C9408 Chassis Fan Module"
PID: N9K-C9400-FAN-PI    ,  VID: V01 ,  SN: N/A

NAME: "Fan 3",  DESCR: "Nexus9000 C9408 Chassis Fan Module"
PID: N9K-C9400-FAN-PI    ,  VID: V01 ,  SN: N/A

NAME: "Fan 4",  DESCR: "Nexus9000 C9408 Chassis Fan Module"
PID: N9K-C9400-FAN-PI    ,  VID: V01 ,  SN: N/A

NAME: "Fan 5",  DESCR: "Nexus9000 C9408 Chassis Fan Module"
PID: N9K-C9400-FAN-PI    ,  VID: V01 ,  SN: N/A

ASW4_QP_LEM#

Displaying the Modules for the Switch

You can display information about the modules, that are installed in the switch by using the show module command.

switch# show module
Mod Ports             Module-Type                       Model          Status
--- ----- ------------------------------------- --------------------- ---------
1    0    Supervisor                            N9K-C9408-SUP-A           active * 
27   0    Virtual Supervisor Module             N9K-C9400-SUP-A           active *

Mod  Sw                       Hw    Slot
---  ----------------------- ------ ----
1    10.3(2)                  0.4    LC1 
27   10.3(2)                  0.4    SUP1

Mod  MAC-Address(es)                         Serial-Num
---  --------------------------------------  ----------
1    60-26-aa-48-c8-40 to 60-26-aa-48-c8-7f  FDO262208WX
27   60-26-aa-48-c8-40 to 60-26-aa-48-c8-7f  FDO262208WX

Mod  Online Diag Status
---  ------------------
1    Pass
27   Pass

* this terminal session 
Lem Ports             Module-Type                       Model          Status
--- ----- ------------------------------------- --------------------- ---------
1    16   16x200G Ethernet Module               N9K-X9400-8D              ok       
 
2    8    8x400G Ethernet Module                N9K-X9400-8D              ok       
 
4    8    8x400G Ethernet Module                N9K-X9400-16W             ok       
 

Mod  Sw                       Hw    Slot
---  ----------------------- ------ ----
1    NA                       0.1010 LC1 
2    NA                       0.1010 LC2 
4    NA                       0.1010 LC4 


Lem  MAC-Address(es)                         Serial-Num
---  --------------------------------------  ----------
1    0c-75-bd-37-2c-fe to 0c-75-bd-37-2d-1d  FOC223620GT
2    0c-75-bd-37-2d-1e to 0c-75-bd-37-2d-3d  FOC224291Q8
4    0c-75-bd-37-2d-5e to 0c-75-bd-37-2d-7d  FOC224291TA

Lem  Online Diag Status
---  ------------------
1    Pass
2    Pass
4    Pass
switch#

Displaying the Serial PROM (SPROM) for the Switch

You can display information about the SPROM, for the switch by using the show sprom command.

switch# show sprom backplane 1 
DISPLAY backplane sprom contents:
Common block:
 Block Signature : 0xABAB
 Block Version   : 3
 Block Length    : 160
 Block Checksum  : 0x168E
 EEPROM Size     : 65535
 Block Count     : 3
 FRU Major Type  : 0x6002
 FRU Minor Type  : 0x0
 OEM String      : Cisco Systems, Inc
 Product Number  : N9K-C9408
 Serial Number   : FOC23086N6A
 Part Number     : 73-19248-01
 Part Revision   : 1
 Mfg Deviation   : 0
 H/W Version     : 0.0
 Mfg Bits        : 0
 Engineer Use    : 0
 snmpOID         : 9.12.3.1.3.1824.0.0
 Power Consump   : -6200
 RMA Code        : 0-0-0-0
 CLEI Code       : 12345678
 VID             : V01
Chassis specific block:
 Block Signature : 0x6001
 Block Version   : 3
 Block Length   : 39
 Block Checksum  : 0x419
 Feature Bits    : 0x0
 HW Changes Bits : 0x0
 Stackmib OID    : 0
 MAC Addresses   : 00-00-ab-cd-dc-ba
 Number of MACs  : 128
 OEM Enterprise  : 0
 OEM MIB Offset  : 0
 MAX Connector Power: 0
WWN software-module specific block:
 Block Signature : 0x6005
 Block Version   : 1
 Block Length    : 0
 Block Checksum  : 0x66
 wwn usage bits:
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00 00 00 00 00 00 00
 00 00
License software-module specific block:
 Block Signature : 0x0
 Block Version   : 0
 Block Length    : 0
 Block Checksum  : 0x0
 lic usage bits:
 00 00 00 00 00 00 00 00
Second Serial number specific block:
 Block Signature : 0x0
 Block Version   : 0
 Block Length    : 0
 Block Checksum  : 0x0
 Serial Number   : 
switch#

Displaying Environmental Information for the Switch

You can display information about the environment, for the switch by using the show environment command.

switch# show environment
Fan:
---------------------------------------------------------------------------
Fan             Model                Hw     Direction       Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  N9K-C9400-FAN-PI     --     front-to-back   Ok
Fan2(sys_fan2)  N9K-C9400-FAN-PI     --     front-to-back   Ok
Fan3(sys_fan3)  N9K-C9400-FAN-PI     --     front-to-back   Ok
Fan4(sys_fan4)  N9K-C9400-FAN-PI     --     front-to-back   Ok
Fan5(sys_fan5)  N9K-C9400-FAN-PI     --     front-to-back   Ok
Fan_in_PS1      --                   --     front-to-back   Ok
Fan_in_PS2      --                   --     front-to-back   Ok
Fan_in_PS3      --                   --     front-to-back   Ok
Fan_in_PS4      --                   --     front-to-back   Ok
Fan Zone Speed: Zone 1: 0x72
Fan Air Filter : NotSupported


Power Supply:
Voltage: 12 Volts
Power                      Actual             Actual        Total
Supply    Model            Output             Input        Capacity     Status
                           (Watts )           (Watts )     (Watts )
-------  ----------  ---------------  ------  ----------  --------------------
1        NXA-PAC-2KW-PI        507 W              552 W      2000 W      Ok
2        NXA-PAC-2KW-PI        555 W              603 W      2000 W      Ok
3        NXA-PAC-2KW-PI        506 W              552 W      2000 W      Ok
4        NXA-PAC-2KW-PI        507 W              552 W      2000 W      Ok


Power Usage Summary:
--------------------
Power Supply redundancy mode (configured)                PS-Redundant
Power Supply redundancy mode (operational)               PS-Redundant

Total Power Capacity (based on configured mode)            6000.00 W
Total Grid-A (first half of PS slots) Power Capacity       4000.00 W
Total Grid-B (second half of PS slots) Power Capacity      4000.00 W
Total Power of all Inputs (cumulative)                     8000.00 W
Total Power Output (actual draw)                           2075.00 W
Total Power Input (actual draw)                            2259.00 W
Total Power Allocated (budget)                                N/A  
Total Power Available for additional modules                  N/A  



Temperature:
--------------------------------------------------------------------
Module   Sensor        MajorThresh   MinorThres   CurTemp     Status
                       (Celsius)     (Celsius)    (Celsius)        
--------------------------------------------------------------------
1        FRONT           55              35          35         Ok            
1        BACK            80              70          36         Ok            
1        CPU             90              80          55         Ok            
1        Quadpeaks       125             100         81         Ok   
ASW4_QP_LEM#

Displaying Environment Temperature for the Switch

You can display information about the environment, for the switch by using the show environment temperature command.

ASW4_QP_LEM# show environment temperature
show environment temperature
Temperature:
--------------------------------------------------------------------
Module   Sensor        MajorThresh   MinorThres   CurTemp     Status
                       (Celsius)     (Celsius)    (Celsius)        
--------------------------------------------------------------------
1        FRONT           55              35          35         Ok  
1        BACK            80              70          36         Ok  
1        CPU             90              80          49         Ok  
1        Quadpeaks       125             100         81         Ok  
ASW4_QP_LEM#