Configuring NetFlow
NetFlow identifies packet flows for ingress IP packets and provides statistics based on these packet flows. NetFlow does not require any change to either the packets themselves or to any networking device.
- NetFlow Overview
- Flow Record
- Flow Exporter
- NetFlow Match Keys
- NetFlow Collect Parameters
- Sampled NetFlow
- Guidelines and Limitations for NetFlow
- How to Configure NetFlow
- Verifying the NetFlow Configuration
- Monitoring NetFlow
- Configuration Examples for NetFlow
NetFlow Overview
NetFlow uses flows to provide statistics for accounting, network monitoring, and network planning. A flow is a unidirectional stream of packets that arrives on a source interface (or VLAN) and has the same values for the keys. A key is an identified value for a field within the packet. You create a flow using a flow record to define the unique keys for your flow.
Cisco NX-OS supports both Traditional Netflow and Flexible NetFlow.
With Traditional NetFlow all of the keys and fields that are exported must be fixed. Traditional Netflow supports IPv4 flows only. You can choose which keys you want to use to define the flow. Each unique flow is cached and some statistics are collected for the flow.
Flexible NetFlow enables enhanced network anomalies and security detection. Flexible NetFlow allows you to define an optimal flow record for a particular application by selecting the keys from a large collection of predefined fields.
All key values must match for the packet to count in a given flow. A flow might gather other fields of interest, depending on the export record version that you configure. Flows are stored in the NetFlow cache.
The flow record determines the type of data to be collected for a flow. The flow monitor combines the flow record and flow exporter with the NetFlow cache information.
Cisco NX-OS gathers NetFlow statistics in sampled mode. This means that packets on the interface or subinterface are analyzed at the configured rate.
Flow Record
A flow record defines the keys that NetFlow uses to identify packets in the flow as well as other fields of interest that NetFlow gathers for the flow. You can define a flow record with any combination of keys and fields of interest. Cisco NX-OS supports a rich set of keys. A flow record also defines the types of counters gathered per flow. You can configure 32-bit or 64-bit packet or byte counters. The key fields are specified with the match keyword. The fields of interest and counters are specified under the match keyword.
Cisco NX-OS enables the following match fields as the defaults when you create a flow record:
Flow Exporter
A flow exporter contains network layer and transport layer details for the NetFlow export packet. You can configure the following information in a flow exporter:
-
Export destination IPv4 or IPv6 address
-
Source interface
-
UDP port number (where the collector is listening for NetFlow packets)
-
Export format
![]() Note | NetFlow export packets use the IP address that is assigned to the source interface. If the source interface does not have an IP address assigned to it, the flow exporter will be inactive. |
Cisco NX-OS exports data to the remote collector, using UDP frames, whenever a timeout occurs. By default, the flow timeout value is set to 15 seconds.
NetFlow Match Keys
To identify a flow you can choose one or more match keys as part of the flow record.
NetFlow supports the following match keys to identify flows:
-
IPv4 source and IPv4 destination addresses
-
IPv6 source and IPv6 destination addresses
-
IPv6 flow label
-
IPv6 options
-
TOS field
-
Layer 4 protocol
-
Layer 4 source and destination ports
Specifying the Match Parameters
You must configure at least one of the following match parameters for flow records:
|
Command |
Purpose |
||
|---|---|---|---|
|
match ip {protocol | tos} Example: switch(config-flow-record)# match ip protocol |
Specifies the IP protocol or ToS fields as keys
|
||
|
match ipv4 {destination address | source address} Example: switch(config-flow-record)# match ipv4 destination address |
Specifies the IPv4 source or destination address as a key. |
||
|
match ipv6 {destination address | source address | flow-label | opitons } Example: switch(config-flow-record)# match ipv6 flow label |
Specifies the IPv6 key. |
||
|
match transport {destination-port | source-port} Example: switch(config-flow-record)# match transport destination-port |
Specifies the transport source or destination port as a key.
|
||
|
match datalink {mac source-address | mac destination-address | ethertype | vlan} Example: switch(config-flow-record)# match datalink ethertype |
Specifies the Layer 2 attribute as a key. |
NetFlow Collect Parameters
![]() Note | Some of these fields might not be available in traditional NetFlow format. |
Specifying the Collect Parameters
You must configure at least one of the following collect parameters for flow records:
|
Command |
Purpose |
|---|---|
|
collect counter {bytes | packets} [long] Example: switch(config-flow-record)# switch(config-flow-record)# collect counter packets |
Collects either packet-based or byte counters from the flow. You can optionally specify that 64-bit counters are used. |
|
collect flow sampler id Example: switch(config-flow-record)# collect flow sampler |
Collects the sampler identifier used for the flow. |
|
collect timestamp sys-uptime {first | last} Example: switch(config-flow-record)# collect timestamp sys-uptime last |
Collects the system up time for the first or last packet in the flow. |
|
collect transport tcp flags Example: switch(config-flow-record)# collect transport tcp flags |
Collects the TCP transport layer flags for the packets in the flow. |
|
collect ip version Example: switch(config-flow-record)# collect ip version |
Collects the IP version for the flow. |
Sampled NetFlow
Cisco NX-OS supports sampled NetFlow. This feature samples incoming packets on an interface. The packets sampled then qualify to create flows. Sampled NetFlow reduces the amount of export data sent to the collector by limiting the number of packets that create flows and the number of flows. It is essential when flows are created on a line card or external device, instead of on the forwarding engine.
| Port Speed | Number of packets using a 1:64K sampled packet rate |
|---|---|
| 1 Gigabit | 23 |
| 10 Gigabit | 230 |
| 40 Gigabit | 920 |
![]() Note | The values in the above table apply to 64 Byte sized packets. The values are different for different size of packets. |
Guidelines and Limitations for NetFlow
NetFlow has the following configuration guidelines and limitations:
-
In sampler mode using M:N, N must be a power of 2. For example 1024, 2048, or 4096.
-
You must configure a source interface. If you do not configure a source interface, the flow exporter will remain in a disabled state.
-
If you configure both NetFlow and SPAN on the same interface then only the SPAN configuration is applied and the NetFlow configuration is ignored.
-
You must configure a valid record name for every flow monitor.
-
The maximum number of supported NetFlow entries is 512,000.
-
You cannot change the fields in a record that is applied on the monitor
-
You cannot change the sampling mode value on a sampler that is applied on the monitor
-
If NetFlow is configured on both SVI and a VLAN then only the routed packets are updated on the SVI NetFlow.
-
NetFlow can cause high CPU loads, to prevent issues with the control plane the following limitations apply: - Ingress layer 2 NetFlow is supported on the following types of interfaces:
- Ingress layer 3 NetFlow is supported on the following types of interfaces:
-
Ingress bridged NetFlow is supported on VLANs.
How to Configure NetFlow
-
Define a flow record by specifying key and non-key fields of interest.
-
Define one or many flow exporters by specifying export format, protocol, destination and other parameters.
-
Define a flow monitor based on the above flow record and flow exporter(s).
-
Apply the flow monitor to an interface with a sampling method specified.
- Enabling the NetFlow Feature
- Creating a Flow Record
- Creating a Flow Exporter
- Creating a Flow Monitor
- Creating a Sampler
- Applying a Flow Monitor to an Interface
- Configuring Bridged NetFlow on a VLAN
- Configuring NetFlow Timeouts
Enabling the NetFlow Feature
You must globally enable NetFlow before you can configure any flows.
| Command or Action | Purpose |
|---|
Creating a Flow Record
Make sure that you are in the correct VDC. To change the VDC, use the switchto vdc command.
Creating a Flow Exporter
The flow exporter configuration defines the export parameters for a flow and specifies reachability information for remote NetFlow collector.
Creating a Flow Monitor
You can create a flow monitor and associate it with a flow record and a flow exporter. All the flows that belong to a monitor use the associated flow record to match on the different fields and the data is exported to the specified flow exporter.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
| Step 2 | flow monitorname
Example: switch(config)# flow monitor flow-monitor-one |
Creates a flow monitor and enters flow monitor configuration mode. You can enter up to 63 alphanumeric characters for the flow monitor name. |
| Step 3 | description
string
Example: switch(config-flow-monitor)# description IPv4Monitor | (Optional)
Describes this flow monitor. You can enter up to 63 alphanumeric characters for the description. |
| Step 4 | exporter
name
Example: switch(config-flow-monitor)# export v9 | (Optional)
Associates a flow exporter with this flow monitor. You can enter up to 63 alphanumeric characters for the exporter name. |
| Step 5 | record {name
netflow-original |
netflow
protocol-port |
netflow {ipv4 |
ipv6}
{original-input |
original-output}}
Example: switch(config-flow-monitor)# record IPv4Flow |
Associates a flow record with the specified flow monitor. You can enter up to 63 alphanumeric characters for the record name. |
| Step 6 | exit
Example: switch(config-flow-monitor)# exit |
Returns to global configuration mode. |
| Step 7 | copy running-config startup-config
Example: switch(config)# copy running-config startup-config | (Optional)
Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration. |
Creating a Sampler
You can create a flow sampler to definer the NetFlow sampling rate for a flow.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
| Step 2 | sampler
name
Example: switch(config)# sampler testsampler |
Creates a sampler and enters flow sampler configuration mode. You can enter up to 63 alphanumeric characters for the flow sampler name. |
| Step 3 | description
string
Example: switch(config-flow-sampler)# description samples | (Optional)
(Optional) Describes this sampler. You can enter up to 63 alphanumeric characters for the description. |
| Step 4 | mode
sample-number
out-of
packet-number
Example: switch(config-flow-sampler)# mode 1 out-of 128 |
Defines the number of samples to take per the number of packets received. The sample-number range is from 1 to 64, and the packet-number range is from 1 to 65536 packets. |
| Step 5 | exit
Example: switch(config-flow-sampler)# exit |
Returns to global configuration mode. |
| Step 6 | copy running-config startup-config
Example: switch(config)# copy running-config startup-config | (Optional)
Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration. |
Applying a Flow Monitor to an Interface
![]() Note | You can not apply a flow monitor to an egress interface, only ingress Netflow is supported. |
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
| Step 2 | interface
interface-type
slot/port
Example: switch(config)# interface ethernet 2/1 |
Enters interface configuration mode. The interface type can be Ethernet (including subinterfaces), port channel, or VLAN interface. |
| Step 3 | ip flow monitor
name
input
sampler
name
Example: switch(config-if)# ip flow monitor testmonitor input sampler testsampler |
Associates an IPv4 flow monitor and a sampler to the interface for input packets. You can enter up to 63 alphanumeric characters for the flow monitor name and the sampler name. |
| Step 4 | ipv6 flow monitor
name
input
sampler
name
Example: switch(config-if)# ipv6 flow monitor testmonitorv6 input sampler testsamplerv6 |
Associates an IPv6 flow monitor and a sampler to the interface for input packets. You can enter up to 63 alphanumeric characters for the flow monitor name and the sampler name. |
| Step 5 | layer2-switched flow
monitor
name
input
sampler
name
Example: switch(config-if)# layer2-switched flow monitor testmonitorl2 input sampler testsamplerl2 |
Associates a Layer 2-switched flow monitor and a sampler to the interface for input packets. You can enter up to 63 alphanumeric characters for the flow monitor name and the sampler name. |
| Step 6 | exit
Example: switch(config-if)# exit |
Returns to global configuration mode. |
| Step 7 | copy running-config startup-config
Example: switch(config)# copy running-config startup-config | (Optional)
Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration. |
Configuring Bridged NetFlow on a VLAN
You can apply a flow monitor and a sampler to a VLAN.
| Command or Action | Purpose | |||
|---|---|---|---|---|
| Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. | ||
| Step 2 | vlan configuration
vlan-id
Example: switch(config)# vlan configuration 30 |
Enters VLAN configuration mode. The vlan-id range is from 1 to 3967 or from 4048 to 4093.
| ||
| Step 3 | {ip
ipv6}
flow
monitor
name
input
sampler
name
Example: switch(config-vlan-config)# ip flow monitor testmonitor input sampler testsampler |
Associates a flow monitor and a sampler to the VLAN for input packets. You can enter up to 63 alphanumeric characters for the flow monitor name and the sampler name. | ||
| Step 4 | exit
Example: switch(config-vlan-config)# exit |
Returns to global configuration mode. | ||
| Step 5 | copy running-config startup-config
Example: switch(config)# copy running-config startup-config | (Optional)
Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration. |
Configuring NetFlow Timeouts
You can optionally configure global NetFlow timeouts that apply to all flows in the system.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
| Step 2 | flow timeoutseconds
Example: switch(config)# flow timeout 30 |
Sets the flush timeout value in seconds. The range is from 5 to 60 seconds. |
| Step 3 | copy running-config startup-config
Example: switch(config)# copy running-config startup-config | (Optional)
Saves the change persistently through reboots and restarts by copying the running configuration to the startup configuration. |
Verifying the NetFlow Configuration
To display the NetFlow configuration, perform one of the following tasks:
|
Command |
Purpose |
|---|---|
|
show flow exporter [name] |
Displays information about NetFlow flow exporters and statistics. You can enter up to 63 alphanumeric characters for the flow exporter name. |
|
show flow interface [interface-type slot/port] |
Displays information about NetFlow interfaces. |
|
show flow record [name] |
Displays information about NetFlow flow records. You can enter up to 63 alphanumeric characters for the flow record name. |
|
show flow record netflow layer2-switched input |
Displays information about the Layer 2 NetFlow configuration. |
|
show flow timeout |
Displays information about NetFlow timeouts. |
|
show sampler [name] |
Displays information about NetFlow samplers. You can enter up to 63 alphanumeric characters for the sampler name. |
Monitoring NetFlow
Use the show flow exporter command to display NetFlow statistics. Use the clear flow exporter command to clear NetFlow flow exporter statistics.
Configuration Examples for NetFlow
Example: Creating and Applying a Flow
This example shows how to create a flow and apply the flow to an interface:
feature netflow flow exporter ee version 9 flow record rr match ipv4 source address match ipv4 destination address collect counter bytes collect counter packets flow monitor foo record rr exporter ee sampler testsampler mode 1 out-of 65536 interface Ethernet2/45 ip flow monitor foo input sampler testsampler ip address 10.20.1.1/24 no switchport
Example: Configuring a NetFlow Exporter
This example shows how to configure a NetFlow exporter configuration for IPv4 :
flow exporter pw destination 172.20.101.87 use-vrf management transport udp 3000 source mgmt0 version 9 flow record pw match ipv4 source address match ipv4 destination address match ip protocol match ip tos match transport source-port match transport destination-port collect counter bytes long collect counter packets long collect timestamp sys-uptime first collect timestamp sys-uptime last collect ip version sampler testsampler mode 1 out-of 65536 flow monitor pw record pw exporter pw interface Ethernet2/9 ip flow monitor pw input sampler testsampler