The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This chapter includes system messages for the Cisco NX-OS Nexus 5000 and Nexus 2000 family of switches. The messages are listed in alphabetical order by the system facility that produces them. Within each system facility section, messages are listed alphabetically by severity and mnemonics. Each error message is followed by an explanation and a recommended action.
Explanation Aaa request rejected as the limit for maximum concurrent aaa sessions is reached
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Upgrading of accounting log failed.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message AAA-2-AAA_PROGRAM_EXIT: aaa daemon exiting: [chars]Explanation Aaa daemon is exiting.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Nvram can not be read/written to. Hence accounting log can not be stored there
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Failed to lookup global port index for interface [chars]
Explanation AAM process could not allocate heap memory in File:[chars], at line:[dec], for memory-type:[dec] of Size:[dec]
Recommended Action No action is required.
Error Message AAM-3-ASSERTION_FAILED: Failed in File:[chars] Line:[dec]Explanation AAM Process assertion failed in File:[chars], at line:[dec]
Explanation Max flow reached in current interval: [chars]
Recommended Action No action is required.
Error Message ACLLOG-4-ACLLOG_THRESHOLD: [chars]Explanation Flow info in current alert interval: [chars]
Recommended Action No action is required.
Error Message ACLLOG-6-ACLLOG_NEW_FLOW: [chars]Explanation The PPF commit failed
Recommended Action No action is required.
Error Message ACLMGR-2-ACLMGR_NO_ERRDISABLED: [chars] event on interface [chars] ([hex]) allowed to succeed in spite of access-list failureExplanation Although an access-list operation failed during a port event, the port event still finished successfully because errdisable is disallowed
Recommended Action No action is required.
Error Message ACLMGR-2-EXITING: Exit reason: [chars]Explanation The ACLMGR service process has exited due to [char]. The process has probably been restarted automatically.
Recommended Action No action is required.
Error Message ACLMGR-2-INITFAIL: ACLMGR Service Init failed: [chars]Explanation ACLMGR Service initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message ACLMGR-2-MALLOC_ERROR: Size [dec] bytesExplanation The ACLMGR service could not allocate memory.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message ACLMGR-2-PSS_ERROR: [chars]: PSS ret. val=[dec]Explanation The ACLMGR service encountered error while operating on a persistent storage database.
Explanation ACL applied to a FEX fabric port or port-channel is not activated
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_ACL_OVER_FAB_CHANNEL: ACL on FEX fabric port-channel bound interface not activatedExplanation ACL applied to a FEX interface is not activated if the interface is bound to a FEX-fabric portchannel
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_DB_LOCK_MSG: ACL database message, reason: [chars], session 0x%llx, type: [chars]Explanation ACL PPF database lock acquire/release related message.
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_PPF_ERROR: PPF error: [chars]Explanation The PPF generated error
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_PSS_CORRUPTED: [chars] PSS found corruptedExplanation The ACLMGR service has detected corruption in one of its persistent information database. The database would be recreated.
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_STAT_CONSOLIDATION_FAILURE: ACL statistic parsing or consolidation failedExplanation A statistic update failed during the parsing or consolidation step; statistics may have been lost
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_VACL_REDIRECTION_DISABLED_REMOVAL: VACL redirection to interface [chars] ([hex]) disabled: the port has been removedExplanation A VACL redirection to the port has been deactivated because the port has been removed
Recommended Action No action is required.
Error Message ACLMGR-3-ACLMGR_VERIFY_FAIL: Verify failed: client %llX, [chars]Explanation The PPF Verify failed
Recommended Action No action is required.
Error Message ACLMGR-3-MTSERROR: [chars]Explanation ACLMGR Service encountered an MTS error. [chars] specifies the context where the error occured.
Explanation The PPF generated warning
Recommended Action No action is required.
Error Message ACLMGR-4-ACLMGR_VACL_REDIRECTION_DISABLED_PCM: VACL redirection to interface [chars] ([hex]) disabled: the port became a portchannel memberExplanation A VACL redirection to the port has been temporarily deactivated because it is now a member in a port channel
Recommended Action No action is required.
Error Message ACLMGR-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec]Explanation There was a version mismatch between the ACLMGR service and one of its persistent storage databases. The persistent information has been translated to the new format.
Explanation The PPF generated notification
Recommended Action No action is required.
Error Message ACLMGR-6-BECAME_ACTIVE: Became ACTIVE from standby modeExplanation The ACLMGR service on the standby supervisor became active and it is ready to serve client requests.
Recommended Action No action is required.
Error Message ACLMGR-6-BECAME_STDBY: Became STANDBY from active modeExplanation The ACLMGR service became standby from active mode.
Recommended Action No action is required.
Error Message ACLMGR-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system manager: Reason=[chars]Explanation The ACLMGR service was unable to send heartbeat to the system manger
Recommended Action No action is required.
Error Message ACLMGR-6-SERVICE_UP: Initialized [chars]Explanation The ACLMGR service is up and ready The service was initialized in [char] mode.
Recommended Action No action is required.
Error Message ACLMGR-6-SRVEXIT: ACLMGR Service shutting down gracefullyExplanation ACLMGR Service is shutting down gracefully. This is an informational message.
Recommended Action No action is required.
Error Message ACLMGR-6-SWITCHOVER: Switching Over to other Sup.Explanation The ACLMGR service has successfully switched over to the standby supervisor card.
Explanation ACLQOS operation failed in the aclqos client
Error Message ACLQOS-SLOT#-2-ACLQOS_INBAND_INTERFACE_FAILURE: Inband interface lif lookup failed ([chars])Explanation Inband interface lif lookup failed
Error Message ACLQOS-SLOT#-2-ACLQOS_MALLOC_FAILED: Memory allocation failed. [chars]Explanation Memory allocation failed. This is a critical failure
Error Message ACLQOS-SLOT#-2-ACLQOS_OOTR: Tcam resource exhausted: [chars]Explanation Tcam resources to program acls exhausted
Error Message ACLQOS-SLOT#-2-PPF_FAILED: Database failure: [chars]Explanation Invalid Congestion Control parameters
Error Message ACLQOS-SLOT#-3-ACLQOS_PAUSE_INVALID: Invalid Pause parametersExplanation Invalid Pause parameters
Error Message ACLQOS-SLOT#-3-ACLQOS_QUEUING_ERROR: ACL/QoS queuing error: [chars]Explanation Tcam will be overused, please turn off atomic update
Error Message ACLQOS-SLOT#-4-ACLQOS_FC_WARNING: Found stale FCoE entry in instance [dec]. VSAN: [dec], SID: [hex], DID: [hex], SI:[dec], SI_MASK:[dec], RW_VSAN: [dec], RW_VSAN_FLAG: [dec], RW_SID: [hex], RW_SID_FLAG: [dec], RW_DID: [hex]. RW_DID_FLAG: [dec] Cleaning it up.Explanation Found stale FCoE entry in instance [dec]. VSAN: [dec], SID: 0x[hex], DID: 0x[hex], SI:[dec], SI_MASK:[dec], RW_VSAN:[dec], RW_VSAN_FLAG: [dec], RW_SID: 0x[hex], RW_SID_FLAG:[dec], RW_DID: 0x[hex]. RW_DID_FLAG: [dec] Cleaning it up.
Error Message Error Message ACLQOS-SLOT#-4-ACLQOS_MATCH_ALL_MERGE_UPDATE: Warning (match_all merging): [chars]Explanation Warning (match_all merging)
Error Message ACLQOS-SLOT#-4-ACLQOS_OVER_THRESHOLD: Tcam [dec] Bank [dec]'s usage has reached its thresholdExplanation Tcam is almost full
Error Message ACLQOS-SLOT#-4-ACLQOS_QUEUING_COS2Q_INVALID: ACL/QoS invalid queuing policy because of cos map change: [chars] queue [chars], interface [chars]Explanation Attemped to configure an invalid queuing policy
Error Message ACLQOS-SLOT#-4-ACLQOS_QUEUING_INVALID: ACL/QoS invalid queuing policy: [chars]Explanation Attemped to configure an invalid queuing policy
Error Message ACLQOS-SLOT#-4-ACLQOS_UNDER_THRESHOLD: Tcam [dec] Bank [dec]'s usage is below the threshold nowExplanation Tcam's usage is below the threshold
Error Message ACLQOS-SLOT#-4-ACLQOS_WARNING: ACLQOS Warning: [chars]Explanation Disruptive IPv6 compression entries update
Error Message ACLQOS-SLOT#-5-ACLQOS_NON_ATOMIC: Non atomic ACL/QoS policy update done for [chars]Explanation ACLTCAM process experienced a failure while programming route for VSAN [dec] SID [chars] DID [chars] due to resource exhaustion. [chars] is the error code.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_ALMOST_FULL: TCAM close to FULL. [chars] TCAM Usage ([dec]/[dec]) exceeded [dec]% fwd-eng: [dec], [chars]Explanation [chars] TCAM usage [dec]/[dec] exceeded [dec] percent on fwd-engine [dec], [chars]
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_CONFIG_READ_FROM_DRIVER_FAILED: [chars] [dec], Error: [hex].Explanation Unable to read configuration from forwarding engine ASIC driver. [chars] [dec], Error: 0x[hex].
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_CONFIG_WRITE_TO_DRIVER_FAILED: [chars] [dec], Error: [hex].Explanation Unable to write configuration to forwarding engine ASIC driver. [chars] [dec], Error: 0x[hex].
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_FLOW_STATS_READ_FAILED: Hardware flow stats read failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: [chars]).Explanation Hardware flow stats read failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_INCONSISTENT_DATABASE: Database found inconsistent.Explanation Database found inconsistent.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_INCONSISTENT_TCAM_CONTENTS: TCAM contents found inconsistent.Explanation TCAM contents are found inconsistent.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_INIT_FAILED: Initialization failed for forwarding engine ASIC: [dec], [chars] TCAM.Explanation Initialization failed for forwarding engine ASIC [dec], in [chars] TCAM.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_INIT_REGIONS_FAILED: Initialization failed for forwarding engine ASIC: [dec], [chars] TCAM, [chars] Region.Explanation Initialization of regions failed for forwarding engine ASIC [dec], in [chars] TCAM, for [chars] Region.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_MALLOC_FAILURE: Memory allocation failed for size [dec].Explanation Memory allocation is failed for size [dec] bytes.
Recommended Action Restart the process.
Error Message ACLTCAM-2-ACL_TCAM_MTS_Q_FULL: MTS queue for SAP [dec] is fullExplanation MTS queue for SAP [dec] is full
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_MTS_FAILURE: MTS operation failed: [chars].Explanation MTS operation failed. [chars] is the reason.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_MTS_REGISTRATION_FAILED: MTS registration failed for opCode: [dec].Explanation MTS registration failed for opCode: [dec].
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_NO_ROUTE: ACLTCAM failed to get route for VSAN: [dec], Rewrite: [chars] DID: [chars] DID MASK: [chars], error: [hex].Explanation ACLTCAM process experienced a failure while getting route for VSAN [dec] Rewrite [chars] DID [chars] DID Mask [chars]. [hex] is the error code.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_NO_TCAM_LEFT: ACLTCAM resource exhausted for interface : [chars]Explanation ACLTCAM hardware resource is completely used.
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_PHY_TCAM_READ_FAILED: [chars] read from hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: [chars]).Explanation [chars] read from hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_PHY_TCAM_READ_INVALID: Invalid([chars], value: [dec]) TCAM entry read from hardware TCAM (FWD-Engine: [dec], [chars] TCAM, Address: [dec]), Ignoring this entry.Explanation Invalid([chars], value: [dec]) TCAM entry from hardware TCAM(FWD-Engine: [dec], [chars] TCAM, Address: [dec]) Ignoring this entry
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_PHY_TCAM_WRITE_FAILED: [chars] write to hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec], Error: [chars]).Explanation [chars] write to hardware TCAM failed(ASIC: [dec], [chars] TCAM, Address: [dec], Num Entries: [dec] Error: [chars]).
Recommended Action No action is required.
Error Message ACLTCAM-2-ACL_TCAM_PSS_FAILURE: Failed to do PSS operation: [chars], reason: [hex].Explanation Failed to do PSS operation [chars]. [hex] is the reason.
Recommended Action No action is required.
Error Message ACLTCAM-2-PSS_OPEN_FAILED: PSS open failed - [hex].Explanation Persistent database handle could not obtained for ACLTCAM. [hex] is the error.
Recommended Action No action is required.
Error Message ACLTCAM-2-RECONS_FAILED: Reconstruction of TCAM contents failed during upgrade - [hex].Explanation During non-disruptive upgrade, the ACLTCAM contents are not properly reconstructed. [hex] is the error.
Explanation TL Port Manager initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message ACLTCAM-3-ACL_TCAM_MTS_Q_LEAK: Possible MTS buffer leak for SAP [dec]Explanation Possible MTS buffer leak for SAP [dec]
Recommended Action No action is required.
Error Message ACLTCAM-3-ALLOCFAIL: Heap Memory allocation failed: [chars]Explanation TL Port Manager is out of dynamic memory. [chars] specifies the context where the failure occured.
Recommended Action No action is required.
Error Message ACLTCAM-3-FC2ERROR: [chars]Explanation TL Port Manager encountered an FC2 error. [chars] specifies the context where the error occured.
Recommended Action No action is required.
Error Message ACLTCAM-3-GENERROR: [chars]Explanation TL Port Manager encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message ACLTCAM-3-MTSERROR: [chars]Explanation TL Port Manager encountered an MTS error. [chars] specifies the context where the error occured.
Recommended Action No action is required.
Error Message ACLTCAM-3-PSSERROR: [chars]Explanation TL Port Manager encountered a PSS error. [chars] specifies the context where the failure occured.
Recommended Action No action is required.
Error Message ACLTCAM-3-REGISTER_FAILED: Could not register to MTS opcode [chars] - error [hex].Explanation ACLTCAM process could not register to the notifications mentioned by [chars]. [hex] is the error.
Explanation [chars] TCAM usage [dec]/[dec] fell below [dec] percent on fwd-engine [dec], [chars]
Recommended Action No action is required.
Error Message ACLTCAM-4-ACL_TCAM_BEYOND_THRESHOLD: [chars] TCAM usage ([dec]/[dec]) exceeded [dec]% fwd-eng: [dec], [chars]Explanation [chars] TCAM usage [dec]/[dec] exceeded [dec] percent on fwd-engine [dec], [chars]
Recommended Action No action is required.
Error Message ACLTCAM-4-ACL_TCAM_FLOW_COUNTER_INVALIDATED: Flow counter for flow: vsan: [dec], sid: [hex], did: [hex] with statistics: frames = %llu & bytes = %llu was invalidated due to: [chars]Explanation ACLTCAM process invalidated the flow counter for flow VSAN [dec] SID [hex] DID [hex] with collected stats of [dec] frames and [dev] bytes was invalidated because of reason [[chars]].
Recommended Action No action is required.
Error Message ACLTCAM-4-ACL_TCAM_FLOW_COUNTER_VALIDATED: Flow counter for flow: vsan: [dec], sid: [hex], did: [hex] is now validExplanation ACLTCAM process validated the flow counter for flow VSAN [dec] SID [hex] DID [hex].
Recommended Action No action is required.
Error Message ACLTCAM-4-ACL_TCAM_MTS_Q_HIGH: MTS queue for SAP [dec] is close to fullExplanation MTS queue for SAP [dec] is close to full
Recommended Action No action is required.
Error Message ACLTCAM-4-TLPM_ALPA_CACHE_FULL: Translation Port ALPA cache is full. Some new entries may not be cachedExplanation TL Port cache is currently fully populated with active entries. Hence, there is no available cache space to be assigned any newly created alpa entry on a TL Port. This is an informational message.
Explanation ACLTCAM status is reported as: [chars].
Recommended Action No action is required.
Error Message ACLTCAM-6-MGRCREATED: Translation Port Manager created.Explanation TL Port Manager was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
Error Message ACLTCAM-6-MGREXIT: Translation Port Manager shutting down gracefully.Explanation TL Port Manager is shutting down gracefully. This is an informational message.
Recommended Action No action is required.
Error Message ACLTCAM-6-PORTDOWN: Translation Port [chars] DOWN.Explanation A port configured as TL Port is DOWN and out of operation. [chars] is the interface-id string that identifies the TL Port. This is an informational message.
Recommended Action No action is required.
Error Message ACLTCAM-6-PORTUP: Translation Port [chars] UP.Explanation A port configured as TL Port is UP and operational. [chars] is the interface-id string that identifies the TL Port. This is an informational message.
Explanation Failed to do high availability operation. [chars] is the reason.
Recommended Action No action is required.
Error Message ACL-2-ACL_INIT_FAILED: Initialization failed for ACL: [chars], reason: [hex].Explanation Initialization failed for ACL due to [chars], reason: [hex].
Recommended Action No action is required.
Error Message ACL-2-ACL_LINECARD_STATUS: Status from linecard: [dec], for module: [chars](ID: [dec]), status : [dec], error_id: [hex], catastrophic: [chars], restart count: [dec].Explanation Status from linecard: [dec], for module: [chars](ID: [dec]), status : [dec], error_id: [hex], catastrophic: [chars], restart count: [dec].
Recommended Action No action is required.
Error Message ACL-2-ACL_MTS_FAILURE: Failed to do MTS operation: [chars].Explanation Failed to do MTS operation. [chars] is the reason.
Recommended Action No action is required.
Error Message ACL-2-ACL_MTS_Q_FULL: MTS queue for SAP [dec] is fullExplanation MTS queue for SAP [dec] is full
Recommended Action No action is required.
Error Message ACL-2-ACL_MTS_REGISTRATION_FAILED: MTS options setting to [hex] failed for opCode: [dec].Explanation MTS options setting to [hex] failed for opCode: [dec].
Recommended Action No action is required.
Error Message ACL-2-ACL_PENDING_MSG_ARR_FULL: ACL Upgrade Pending Messages Array is Full with [dec] messages. Failing the MTS message with Opc: [dec], RR_TOKEN: [hex]Explanation ACL Upgrade Pending Messages Array is Full with [dec] messages. Failing the MTS message with Opc: [dec], RR_TOKEN: [hex]
Recommended Action No action is required.
Error Message ACL-2-ACL_PSS_FAILURE: Failed to do PSS operation: [chars], reason: [hex].Explanation Failed to do PSS operation [chars]. [hex] is the reason.
Recommended Action No action is required.
Error Message ACL-2-ACL_PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], expected version [dec].[dec].[dec].Explanation There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version.
Recommended Action No action is required.
Error Message ACL-2-ACL_RUNTIME_FAILURE: [chars] [dec], Error: [hex]Explanation ACL runtime failure is reported as [chars] [dec], reason: [hex].
Recommended Action No action is required.
Error Message ACL-2-ACL_TCAM_FAILURE: Failed to do TCAM operation: [chars].Explanation Failed to do TCAM operation. [chars] is the reason.
Explanation MTS queue for SAP [dec] is close to full
Recommended Action No action is required.
Error Message ACL-4-ACL_WARNING: [chars] [dec]Explanation ACL warning messages is reported as [chars] [dec].
Explanation Successfully completed the command \[chars]\ on Generation 2 linecards.
Explanation ACL system health management event status is reported as [chars] [hex].
Recommended Action No action is required.
Error Message ACL-6-ACL_E_PORT_EVENT_STATUS: [chars] [chars].Explanation ACL xEport event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_FCC_EVENT_STATUS: [chars] [chars].Explanation ACL FCC event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_LINECARD_EVENT_STATUS: [chars] [hex].Explanation ACL linecard event status is reported as [chars] [dec].
Recommended Action No action is required.
Error Message ACL-6-ACL_MCAST_EVENT_STATUS: [chars] [chars].Explanation ACL multicast event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_NX_PORT_EVENT_STATUS: [chars] [chars].Explanation ACL Nx Port event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_PORT_MODE_EVENT_STATUS: [chars] [chars].Explanation ACL portmode event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_RUNTIME_STATUS: [chars] [dec]Explanation ACL runtime status is reported as [chars] [dec].
Recommended Action No action is required.
Error Message ACL-6-ACL_SPAN_DEST_CONFIG_STATUS: [chars] [chars].Explanation ACL SPAN destination config event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_SPAN_SRC_CONFIG_STATUS: [chars] [chars].Explanation ACL SPAN source config event status is reported as [chars] [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_STATUS: ACL Status: [chars].Explanation ACL status is reported as [chars].
Recommended Action No action is required.
Error Message ACL-6-ACL_UPDATE_SSRAM_QOS_EVENT_STATUS: [chars] [chars].Explanation ACL update SSRAM for QoS event status is reported as [chars] [chars].
Explanation At least one command failed while Ascii configuration was being applied
Recommended Action No action is required.
Error Message ASCII-CFG-2-ACFG_LIB_INVOKE_ERR: Ascii config library invocation error: [chars]Explanation Error encountered while library function was being invoked to display Ascii configuration
Recommended Action No action is required.
Error Message ASCII-CFG-2-ACFG_OPER_FAIL: Operation failed because of [chars]Recommended Action No action is required.
Error Message ASCII-CFG-2-ACFG_ROLLBACK_FAILED: Rollback to checkpoint [chars] Failed, Going to undo the changes (atomic option)Explanation Rollback operation failed for atomic option
Recommended Action No action is required.
Error Message ASCII-CFG-2-ACFG_ROLLBACK_UNDO_FAILED: Undo failed for atomic Rollback, Please correct the error manually and retry rollbackExplanation Undoing the rollback changes (for atomic behavior) Failed
Recommended Action No action is required.
Error Message ASCII-CFG-2-ACFG_SYSLOG_INIT_FAILED: Ascii config Syslog Init ErrorExplanation Error encountered while Initializing Syslog for Ascii Config
Recommended Action No action is required.
Error Message ASCII-CFG-2-PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], expected version [dec].[dec].[dec]Explanation There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Ascii-cfg-server (rollback process) encountered an MTS error. [chars] specifies the context where the error occurred.
Explanation Cleared all the configuration checkpoints
Recommended Action No action is required.
Error Message ASCII-CFG-6-ACFG_CHECKPOINT_CREATED: Created configuration checkpoint [chars]Explanation Created configuration checkpoint
Recommended Action No action is required.
Error Message ASCII-CFG-6-ACFG_CHECKPOINT_DELETED: Deleted configuration checkpoint [chars]Explanation Deleted configuration checkpoint
Recommended Action No action is required.
Error Message ASCII-CFG-6-ACFG_MAX_CHECKPOINTS: Maximum no of checpoints reached, Removing the oldest checkpointExplanation Maximum no.of checkpoints reached, removing the oldest checkpoint
Recommended Action No action is required.
Error Message ASCII-CFG-6-ACFG_ROLLBACK_ATOMIC: Performing configuration rollback to checkpoint [chars] (with atomic option)Explanation Performing configuration rollback with atomic option
Recommended Action No action is required.
Error Message ASCII-CFG-6-ACFG_ROLLBACK_BEST: Performing configuration rollback to checkpoint [chars] (with best-effort option)Explanation Performing configuration rollback with best-effort option
Recommended Action No action is required.
Error Message ASCII-CFG-6-ACFG_ROLLBACK_FIRST_ERR: Performing configuration rollback to checkpoint [chars] (with stop-at-first failure option)Explanation Performing configuration rollback with stop-at-first-failure option
Recommended Action No action is required.
Error Message ASCII-CFG-6-INFORMATION: [chars]Explanation An event happend that affects Acfg-Rollback. [chars] indicates the event
Recommended Action No action is required.
Error Message ASCII-CFG-6-PSS_ERR: [chars]Explanation An error occurred during an Acfg PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Association Manager Emergency Message
Recommended Action Please file the bug for Association Manager Component thro' CDETS
Explanation Association Manager Alert Message
Recommended Action Association Manager Internal Operation Alert
Explanation Association Activated
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_CREATED: Association Created for vlan id:[dec] <--> vsan id:[dec]Explanation Association Created
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_DEACTIVATED: Association Deactivated for vlan id: [dec] <--> vsan id: [dec]Explanation Association Deactivated
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_DELETED: Association Deleted for vlan id: [dec] <--> vsan id: [dec]Explanation Association Deleted
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_MGR_STATEFULL_RESTART: Association Manager Statefull RestartExplanation Association Manager Stateful Restart
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_MGR_STATELESS_RESTART: Association Manager Stateless RestartExplanation Association Manager Stateless Restart
Recommended Action No action is required.
Error Message ASSOC_MGR-6-ASSOC_OPER_STATUS_CHG: Association status for vlan id: [dec] <--> vsan id: [dec] changed from [chars] to [chars]Explanation Association Operational State Change
Recommended Action No action is required.
Error Message ASSOC_MGR-6-INFO_MSG: [chars]Explanation Association Manager Debug Message
Recommended Action Perform additional debugging to resolve the issue.
Explanation This message provides additional information about errors related to authentication and SSH.
Explanation General failure. This is a critical failure
Error Message BFDC-SLOT#-2-BFDC_MALLOC_FAILED: Memory allocation failed. [chars]Explanation Memory allocation failed. This is a critical failure
Error Message BFDC-SLOT#-2-BFDC_MTS_FAILURE: MTS failure. [chars]Explanation BFD session [chars] installation failed due to ACL installation failure interface [chars
Recommended Action Maximum acl install retries exceeded. Please to free up acl resources
Error Message BFD-3-SESSION_ACL_REMOVE_GAVE_UP: BFD session [chars] removal failed due to ACL removal failure interface [chars]Explanation BFD session [chars] removal failed due to ACL removal failure interface [chars
Recommended Action Maximum acl removal retries exceeded. Please manually remove bfd sessions
Error Message BFD-3-SESSION_CREATE_FAIL: Failed to create BFD session to neighbor [chars] over intertface [chars]. Reason [chars]Explanation Failed to create BFD session to neighbor [chars] over intertface [chars] Reason [chars]
Recommended Action SYSLOGDPC_NO_ACTION
Error Message BFD-3-REACHED_CAPACITY_LIMIT: BFD session [chars] creation on interface [chars] failed due to capacity limit [dec]Explanation BFD session [chars] creation on interface [chars] failed due to current capacity limit [dec]
Recommended Action Please remove current bfd sessions to make room for new ones
Explanation Attempt to register BFD session on invalid neighbor: [chars] type that is not supported by BFD for application [chars].
Recommended Action No action is required.
Error Message BFD-4-SESSION_DELETE_FAIL: Attempt to delete BFD session [chars] failed: Reason [chars] ([hex]).Explanation Attempt to delete [dec] BFD session[chars] failed: Reason [chars] ([hex]).
Recommended Action No action is required.
Error Message BFD-4-SESSION_DELETE_FAIL: Attempt to delete BFD session for neighbor [chars] failed: Reason [chars] ([hex]).Explanation Attempt to delete BFD session for neighbor [chars] failed: Reason [chars] (0x[hex]).
Explanation BFD Service Disabled
Recommended Action No action is required.
Error Message BFD-5-BFD_ENABLED: BFD EnabledExplanation BFD Service nabled
Recommended Action No action is required.
Error Message BFD-5-BFD_SESSION_ADD: BFD session [hex] addedExplanation BFD Service Disabled
Recommended Action No action is required.
Error Message BFD-5-BFD_SESSION_DOWN: BFD session [hex] downExplanation BFD Service Disabled
Recommended Action No action is required.
Error Message BFD-5-BFD_SESSION_REM: BFD session [hex] removedExplanation BFD Service Disabled
Recommended Action No action is required.
Error Message BFD-5-BFD_SESSION_UP: BFD session [hex] upExplanation BFD Service Disabled
Recommended Action No action is required.
Error Message BFD-5-SESSION_ACTIVE_PARAMS_CHANGE: Local parameter of BFD session [hex] has changed [chars]Explanation Local parameter of BFD session 0x[hex] has changed [chars]
Recommended Action No action is required.
Error Message BFD-5-SESSION_LOCAL_PARAMS_CHANGE: Local parameter of BFD session [hex] has changed [chars]Explanation Local parameter of BFD session 0x[hex] has changed [chars]
Recommended Action No action is required.
Error Message BFD-5-SESSION_MOVED: BFD session [hex]: [chars]Explanation BFD session 0x[hex]: [chars]
Recommended Action No action is required.
Error Message BFD-5-SESSION_STATE_DOWN: BFD session [chars] to neighbor [chars] on interface [chars] has gone down. Reason: [hex].Explanation BFD session [chars] to neighbor [chars] on interface [chars] has gone down. Reason: 0x[hex]. This may be as a result of the forwarding path being down.
Explanation BFD session [chars] failed due to missing ACL resources for interface [chars]
Recommended Action No action is required.
Error Message BFD-6-SESSION_ACL_REMOVE_FAILED: BFD session [chars] removal failed due to missing ACL resources for interface [chars]Explanation BFD session [chars] removal failed due to missing ACL resources for interface [chars]
Recommended Action No action is required.
Error Message BFD-6-SESSION_CREATED: BFD session to neighbor [chars] on interface [chars] has been createdExplanation BFD session to neighbor [chars] on interface [chars]
Recommended Action No action is required.
Error Message BFD-6-SESSION_LOCAL_PARAMS_CHANGE: Local parameter of BFD session [chars] has changed: [chars]Explanation Local parameter of BFD session [chars] has changed: [chars]
Recommended Action No action is required.
Error Message BFD-6-SESSION_MOVED: BFD session [chars] has moved from [chars] to [chars]Explanation BFD session [chars] has moved from [chars] to [chars]
Recommended Action No action is required.
Error Message BFD-6-SESSION_NO_RESOURCES_CLR: Lack of resources condition has cleared for session to neighbor [chars] on interface [chars]Explanation Lack of resources condition has cleared for session to neighbor [chard] on interface [char].
Recommended Action No action is required.
Error Message BFD-6-SESSION_NO_RESOURCES: No resource for session to neighbor [chars] on interface [chars]Explanation The BFD session can not be created or modified due to lack of resources. No resources for session to neighbor [chars]
Recommended Action Remove other BFD sessions to free resources for this session
Error Message BFD-6-SESSION_REMOVED: BFD session to neighbor [chars] on interface [chars] has been removedExplanation BFD session to neighbor [chars] on interface [chars]
Recommended Action No action is required.
Error Message BFD-6-SESSION_STATE_DOWN: BFD session [chars] to neighbor [chars] on interface [chars] has gone down. Reason: [hex].Explanation BFD session [chars] to neighbor [chars] on interface [chars] has gone down. Reason: [hex]. This may be as a result of the forwarding path being down.
Recommended Action No action is required.
Error Message BFD-6-SESSION_STATE_UP: BFD session [chars] to neighbor [chars] on interface [chars] is up.Explanation BFD session [chars] to neighbor [chars] on interface [chars] is up.
Explanation BIOS CHIP NOT SUPPORTED
Recommended Action No action is required.
Error Message BIOS_DAEMON-2-BIOS_DAEMON_PRI_BOOT_FAIL: System booted from Alternate BIOS FlashExplanation Boot from Alternate
Recommended Action SYSLOGDOC_NOACTION
Error Message BIOS_DAEMON-2-BIOS_DAEMON_SUP_ERROR: BIOS Sector ([dec]) is write protectedExplanation BIOS WRITE PROTECTED
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation BIOS WRITE PROTECTED
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message BIOS_DAEMON-SLOT#-2-BIOS_DAEMON_LC_PRI_BOOT_FAIL: System booted from Alternate BIOS FlashExplanation Online diagnostics EOBC test has failed
Recommended Action No action is required.
Error Message BOOTUP_TEST-2-EOBC_SKIP: Module [dec] has failed test [chars] on EOBC due to error [chars]Explanation Online diagnostics ManagementPort test has failed
Recommended Action No action is required.
Error Message BOOTUP_TEST-2-MGMT_PORT_FAIL: Module [dec] has failed test [chars] on Management Port due to error [chars]Explanation Online diagnostics ManagementPort test has failed
Recommended Action No action is required.
Error Message BOOTUP_TEST-2-MGMT_PORT_SKIP: Module [dec] has skipped test [chars] on Management Port due to error [chars]Explanation Online diagnostics ManagementPort test is skipped
Explanation The service failed to allocate memory.
Recommended Action Check if the system is low on memory, if so reset the switch.
Error Message BOOTVAR-2-AUTOCOPY_FAILED: Autocopy of file [chars] to standby failed. [chars] (Error-id: [hex])Explanation The image deemed to be copied to standby via the auto-copy feature failed.
Recommended Action Check error id for specified reason.
Error Message BOOTVAR-2-AUTOSYNC_FAILED: Image autosync failed. Reason: [chars] ([hex])Explanation Image synchronization failed.
Recommended Action Check that there is enough space on the flash, as well as system high availability status.
Error Message BOOTVAR-2-CONFIG_ERROR: Failed to update boot configurationExplanation An error has occurred during the update of the boot configuration files
Recommended Action Check that there is enough space on the flash, show boot to check the configured image names, show loader internal configuration to compare them with the current bootloader configuration, if they are not coherent do write erase and retry to save the configuration.
Error Message BOOTVAR-2-IMAGE_NOT_COMPATIBLE: Warning: image [chars] is not compatible with the current platform in SUP [dec]Explanation The input image name is not compatible with the current platform.
Recommended Action Make sure a right image is specified before reboot.
Explanation There is not enough disk space on the standby for the file to be copied.
Recommended Action Clear space on the standby disk.
Error Message BOOTVAR-3-INIT_FAILED: Initialization failed: Component [chars]Explanation The service failed to start The failure occurs during initialization of the component [chars].
Recommended Action Show processes to check the status of the other processes, pay attention to the specified component.
Error Message BOOTVAR-3-LOAD_VERIFY_LIB_FAILED: Fetching library [chars] failed, reason=[chars]Explanation Failed to load bootvar specified verification library.
Recommended Action No action is required.
Error Message BOOTVAR-3-MODULE_LOCK_FAIL: Unable to get module lock, please don't reload <error-id:[hex]>Explanation Unable to acquire modlock to prevent user to reload during auto-sync.
Recommended Action No action is required.
Error Message BOOTVAR-3-NEIGHBOR_REJECT_AUTOCOPY: auto-copy failed - not supported by neighbor supervisor.Explanation Standby supervisor does not support auto-copy, thus failed.
Recommended Action No action is required.
Error Message BOOTVAR-3-VERIFY_FAILED: Image [chars] for bootvar [chars] verification failed, reason=[chars]Explanation The image set for this bootvar has failed the verification process, this is just a warning.
Explanation Auto copy of the file succeed, image integrity verified by standby.
Recommended Action No action is required.
Error Message BOOTVAR-5-AUTOCOPY_VERIFY_SEND_FAILED: Unable to ask standby to verify file [chars], error = [hex]Explanation Upon copied the image to standby, failed to send message to ask standby to verify integrity.
Recommended Action Turn auto-copy off and back on.
Error Message BOOTVAR-5-AUTOSYNC_DONE: Image autosync doneExplanation The image synchronization done successfully.
Recommended Action No action is required.
Error Message BOOTVAR-5-AUTOSYNC_REBOOT: Rebooting standby after successful autosyncExplanation Image autosync has been successful, resetting the standby supervisor to load the new image.
Recommended Action Check that the standby sup reloads correctly.
Error Message BOOTVAR-5-AUTOSYNC_START: Starting image autosync. Please wait until completion...Explanation The standby-sup has requested the sync of the current image.
Recommended Action No action is required.
Error Message BOOTVAR-5-IMAGE_NOTEXISTS: Warning: image [chars] doesn't exist on sup[dec]Explanation The input image name doesn't exist on the specified supervisor.
Recommended Action Check whether the input image name you entered exists and make sure that you have the image on the flash before reboot.
Error Message BOOTVAR-5-NEIGHBOR_UPDATE_AUTOCOPY: auto-copy supported by neighbor supervisor, starting...Explanation Info log reporting standby's support of auto-copy. Auto-copy is being started.
Explanation No need to update the image on the standby-sup.
Recommended Action No action is required.
Error Message BOOTVAR-6-AUTOCOPY_DID_NOT_START: Autocopy of file [chars] to standby did not start. [chars] (Error-id: [hex])Explanation Autocopy of the file did not start as the remote copy location does not exist
Recommended Action No action is required.
Error Message BOOTVAR-6-CONFIG_UPDATED: Boot configuration updatedExplanation The boot-loader configuration files have been successfully updated.
Recommended Action No action is required.
Error Message BOOTVAR-6-STARTING: Boot configuration initializedExplanation Callhome event [chars] occurred.
Recommended Action If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error
Error Message CALLHOME-2-PROGRAM_EXIT: callhome process ending: [chars]Explanation Callhome process is exiting with reason [chars].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CALLHOME-3-CALLHOME_CFS_OPERATION_FAILED: [chars] : [chars]Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CALLHOME-3-CALLHOME_MAX_ALERT_MSG: [chars]Recommended Action Please check the reason for the generation of the callhome messages and rectify the problem
Error Message CALLHOME-3-EVENT_PROCESS_ERROR: error in processing callhome event [chars] reason:[chars]Explanation Error in processing callhome event [chars] reason:[chars]
Recommended Action Please check your callhome configuration for proper configuration. Please check SMTP server address, email addresses for destination profiles and enable status of callhome. Use show callhome commands for displaying configuration.
Error Message CALLHOME-3-MESSAGE_SIZE_EXCEED: message size for callhome alert:[chars] exceeds maximum limit for destination profile:[chars]Explanation Message size for callhome alert:[chars] exceeds maximum limit for destination profile:[chars]
Recommended Action Please check the maximum message size for the destination profile under question. Increase it if possible to match the maximum limit allowed by your email destinations.
Explanation Non-critical Callhome event [chars] occurred.
Recommended Action If you have configured your email address to receive callhome notifications, please check your email for more details about this callhome event. If callhome was not enabled, please execute CLI commands relevant to the callhome event to get more information about the error
Explanation CDP Daemon Initialization failed. [chars] explains the reason for the failure.
Explanation CDP Daemon is out of dynamic memory. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message CDP-3-GENERROR: [chars]Explanation CDP Daemon encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message CDP-3-MCASTBINDFAIL: Failed to bind for CDP multicast address on interface [hex] - [chars]Explanation An attempt to register for packets destined to the CDP multicast address failed. [dec] identifies the interface [char] identifies the reason.
Recommended Action No action is required.
Error Message CDP-3-MTSERROR: [chars]Explanation CDP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message CDP-3-PKTRECVFAIL: Failed to receive packet - [chars]Explanation Failed to receive packet. [char] identifies the reason.
Recommended Action No action is required.
Error Message CDP-3-PKTSENDFAIL: Failed to send packet, interface [hex] - [chars]Explanation Failed to send packet. [dec] identifies the interface [char] identifies the reason.
Recommended Action No action is required.
Error Message CDP-3-PSSERROR: [chars]Explanation CDP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message CDP-3-SOCKBINDFAIL: Failed to bind to raw socket, interface [hex] - [chars]Explanation Failed to bind to raw socket. [dec] identifies the interface [char] identifies the reason.
Recommended Action No action is required.
Error Message CDP-3-SOCKOPENFAIL: Failed to open socket for receiving raw 802_2 packets - [chars]Explanation An attempt to open a socket for receiving raw 802_2 packets failed. [char] identifies the reason.
Explanation Duplex mismatch discovered from the received cdp packet This is a warning message.
Recommended Action No action is required.
Error Message CDP-4-NATIVE_VLAN_MISMATCH: Native VLAN mismatch discovered on [chars]([dec]), with [chars]([dec])Explanation Native VLAN mismatch discovered This is a warning message.
Explanation CDP is disabled on the device.
Recommended Action No action is required.
Error Message CDP-5-ENABLED: CDP is enabledExplanation CDP is enabled on the device.
Recommended Action No action is required.
Error Message CDP-5-NEIGHBOR_ADDED: Device [chars] discovered of type [chars] with port [chars] on incoming port [chars] with ip addr [chars] and mgmt ip [chars]Explanation Discovered a neighbor device. This is an informational message.
Recommended Action No action is required.
Error Message CDP-5-NEIGHBOR_REMOVED: CDP Neighbor [chars] on port [chars] has been removedExplanation Deleted a neighbor device. This is an informational message.
Explanation CDP Daemon was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-CDPEXIT: CDP Daemon shutting down gracefully.Explanation CDP Daemon is shutting down gracefully. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTDISABLE: CDP disabled on port [chars]Explanation CDP was disabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTDOWN: A CDP enabled port [chars] went down.Explanation A CDP enabled port became un-operational. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTENABLE: CDP enabled on port [chars]Explanation CDP was enabled on a given port. [chars] is the interface-ID string that identifies the port. This is an informational message.
Recommended Action No action is required.
Error Message CDP-6-PORTUP: A CDP enabled port [chars] came up.Explanation A CDP enabled port became operational. [chars] is the interface-ID string that identifies the port. This is an informational message.
Explanation Cert_enroll daemon is exiting.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation CERT_ENROLL Error Message
Recommended Action No action is required.
Error Message CERT_ENROLL-3-CERT_EN_FIPS_MODE_INIT_ERROR: Could not initialize FIPS mode : [chars]Explanation CFS reject: [chars] Switch WWN [chars], ip [chars], reason [chars]
Recommended Action No action is required.
Error Message CFS-2-EXITING: Exit reason: [chars]Explanation The CFS service process has exited due to [char]. The process has probably been restarted automatically.
Recommended Action No action is required.
Error Message CFS-2-GENERAL_ERROR: [chars]Explanation The CFS service has encountered an critical error. The description of error is [str.]
Recommended Action No action is required.
Error Message CFS-2-INITFAIL: CFS Service Init failed: [chars]Explanation CFS Service initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message CFS-2-LOCK_FAILED: lock failed for sap [dec] due to internal error.Explanation Lock failed due to Unrestricted uncoordinated count is out of sync for sap [dec]
Recommended Action To recover from this state run command 'cfs internal decrement-unrestricted <app-sap>'
Error Message CFS-2-MALLOC_ERROR: Size [dec] bytesExplanation The CFS service could not allocate memory.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message CFS-2-MTS_REJECT: Verification failed reject MTS message SAP [dec]:RR-token [hex]Explanation This MTS message could have been posted by the previous active running pre 3.x; MTS structure has changed since then hence ignore the MTS message, Source SAP [dec]; RR-token [hex]
Recommended Action No action is required.
Error Message CFS-2-PSS_ERROR: [chars]: PSS ret. val=[dec]Explanation The CFS service encountered error while operating on a persistent storage database.
Recommended Action No action is required.
Error Message CFS-2-VDC_MGR_FAIL: Failed to get a valid switch mac from VDC Manager: [chars]Explanation VDC manager did not respond with a proper MAC address. It could have been because of a timeout in MTS received
Explanation CFS Service is out of dynamic memory. [chars] specifies the context where the failure occured
Recommended Action No action is required.
Error Message CFS-3-APP_MERGE_FAILED: Merge failed for app [chars], local switch wwn [chars], remote switch wwn [chars].Please check 'show cfs merge status name [chars]' for more informationExplanation The CFS service has detected a merge failure.
Recommended Action No action is required.
Error Message CFS-3-CFS_PSS_CORRUPTED: [chars] PSS found corruptedExplanation The CFS service has detected corruption in one of its persistent information database. The database would be recreated.
Recommended Action No action is required.
Error Message CFS-3-DBERROR: [chars]Explanation CFS Service encountered a database error. [chars] specifies the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-FAILURE_RESPONSE: [chars] [hex]Explanation CFS Service failed to get response [chars][hex] specify the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-FIPS_TEST_FAILED: FIPS compliance test failedExplanation FIPS compliance test failed
Recommended Action No action is required.
Error Message CFS-3-GENERROR: [chars]Explanation CFS Service encountered a general error, one that does not fall in any of the above categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message CFS-3-LICERR: [chars]Explanation CFS Service failed to get license.
Recommended Action No action is required.
Error Message CFS-3-MERGE_FAILED: Merge failed for app [chars], local switch wwn [chars],ip [chars], remote switch wwn [chars], ip [chars]Explanation The CFS service has detected a merge failure.
Recommended Action No action is required.
Error Message CFS-3-MTSERROR: [chars]Explanation CFS Service encountered an MTS error. [chars] specifies the context where the error occured.
Recommended Action No action is required.
Error Message CFS-3-PSSERROR: [chars]Explanation CFS Service encountered a PSS error. [chars] specifies the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-TIMEOUT_ERROR: [chars] [hex]Explanation CFS Service encountered a timeout [chars][hex] specify the context where the failure occured.
Recommended Action No action is required.
Error Message CFS-3-UNKNOWN_MSG: Recvd. from Node=[dec] SAP=[dec]Explanation The CFS service has received an unknown message from [dec]].[dec]. This information is for debugging only.
Explanation CFS Service license is going to expire. [chars] gives the expected time of expiry
Recommended Action No action is required.
Error Message CFS-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec]Explanation There was a version mismatch between the CFS service and one of its persistent storage databases. The persistent information has been translated to the new format.
Explanation The CFS service on the standby supervisor became active and it is ready to serve client requests.
Recommended Action No action is required.
Error Message CFS-6-BECAME_STDBY: Became STANDBY from active modeExplanation The CFS service became standby from active mode.
Recommended Action No action is required.
Error Message CFS-6-EXCESSIVE_DELAY: [chars]Explanation Excessive time taken for a processing event. The description of the event is [str.]
Recommended Action No action is required.
Error Message CFS-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system manager: Reason=[chars]Explanation The CFS service was unable to send heartbeat to the system manger
Recommended Action No action is required.
Error Message CFS-6-GENERAL_EVENT: [chars]Explanation The CFS service has generated an important event. The description of the event is [str.]
Recommended Action No action is required.
Error Message CFS-6-INVALID_CHECKSUM: Received packet from peer on if-index([hex]) with corrupted checksumExplanation This could be because of errors in the link
Recommended Action No action is required.
Error Message CFS-6-INVALID_IF_INDEX: Received packet on if-index([hex]) which is not recognized by CFSExplanation The if-index does not match with the if-index used in discovery or we might have already recieved an adjacency cleanup message for this if-index. Check if the if-index is that of the port-channel or a physical if-index
Recommended Action No action is required.
Error Message CFS-6-LOGICAL_DISTRIBUTION_INFO: vsan [dec], source wwn [chars], ip [chars] app-id [dec], session-id [dec], user [chars], [chars]Explanation Vsan [dec], source wwn [chars], ip [chars], app-id [dec], user [chars], event [chars]
Recommended Action No action is required.
Error Message CFS-6-PHY_DISTRIBUTION_INFO: source wwn [chars], ip [chars], app-id [dec], session-id [dec], user [chars], [chars]Explanation Source wwn [chars], ip [chars], app-id [dec], session-id [dec], user [chars], event [chars]
Recommended Action No action is required.
Error Message CFS-6-PSS_CREATED: [chars] PSS CreatedExplanation One of the persistent information database of CFS service has been recreated
Recommended Action No action is required.
Error Message CFS-6-PSS_DESTROYED: [chars] PSS DestroyedExplanation One of the persistent information databases of CFS Service has been intentionally destroyed and would be recreated.
Recommended Action No action is required.
Error Message CFS-6-REGION_CTX_REMOVED: Region info is deleted for [chars]Explanation [chars] is in logical scope. Regions are supported only physical scope applications
Recommended Action No action is required.
Error Message CFS-6-SERVICE_UP: Initialized [chars]Explanation The CFS service is up and ready to accept client requests The service was initialized in [char] mode.
Recommended Action No action is required.
Error Message CFS-6-SRVCREATED: CFS Service createdExplanation CFS Service was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
Error Message CFS-6-SRVEXIT: CFS Service shutting down gracefullyExplanation CFS Service is shutting down gracefully. This is an informational message.
Recommended Action No action is required.
Error Message CFS-6-SWITCHOVER: Switching Over to other Sup.Explanation The CFS service has successfully switched over to the standby supervisor card.
Explanation Exit due to critical error
Recommended Action No action is required.
Error Message CIMSRVPROV-2-CIM_SYSLOG_PSS_SNAPSHOT_ERR: Source URI:[chars] Destination URI:[chars] errcode:[dec]Explanation PSS snapshot error
Recommended Action No action is required.
Error Message CIMSRVPROV-2-CIM_SYSLOG_SDWRAP_ERR: Description:[chars] errcode:[dec]Explanation Copy running startup error
Recommended Action No action is required.
Error Message CIMSRVPROV-3-CIM_SYSLOG_FILE_ERR: Purpose:[chars] Filename:[chars] errcode:[dec]Explanation File handling error
Recommended Action No action is required.
Error Message CIMSRVPROV-3-CIM_SYSLOG_MTS_ERR: message [chars]Explanation MTS message handling error
Recommended Action No action is required.
Error Message CIMSRVPROV-3-CIM_SYSLOG_PSS_ERR: Purpose:[chars] URI:[chars] errcode:[dec]Explanation Cleared a certificate named [chars].
Recommended Action No action is required.
Error Message CIMSRVPROV-6-LOG_CIM_CERTIFICATE_INSTALLED: Installed certificate [chars]Explanation Cloud-discovery process is exiting with reason [chars].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CLOUD-3-CLOUD_CFS_OPERATION_FAILED: [chars] : [chars]Recommended Action Please check the reason for the failure of the cfs operation and rectify the problem
Error Message CLOUD-3-CLOUD_FEATURE_MANAGER_ERROR: [chars] : [chars]Recommended Action Please check the reason for error using feature manager and rectify the problem
Error Message CLOUD-3-CLOUD_PSS_OPERATION_FAILED: [chars] : [chars]Recommended Action Please check the reason for the failure of the pss operation and rectify the problem
Explanation Cloud-discovery started
Recommended Action Check cloud membership
Error Message CLOUD-6-CLOUD_DISCOVERY_STARTED: [chars] discovery startedExplanation Cloud-discovery started
Recommended Action Check cloud-discovery status after sometime
Explanation Cluster capability addition failed
Recommended Action No action is required.
Error Message CLUSTER-2-CLUSTER_CAP_DEL_FAIL: Failed to delete cluster capability [dec]Explanation Connectivity Management processor is not sending heartbeats on this module
Recommended Action No action is required.
Error Message CMPPROXY-2-LOG_CMP_UP: Connectivity Management processor(on module [dec]) is now UPExplanation Connectivity Management processor has come up and is exchanging heartbeats with CP on this SUP slot
Recommended Action No action is required.
Error Message CMPPROXY-2-LOG_CMP_WENT_DOWN: Connectivity Management processor (on module [dec]) went DOWNExplanation Connectivity Management processor has either gone down or is not sending heartbeats for a long time
Explanation A login attempt has been denied access from Connectivity management processor (CMP) as authentication did not succeed
Recommended Action No action is required.
Error Message CMPPROXY-5-MALLOC_FAILURE: Memory allocation failureExplanation Memory allocation in a call to malloc/calloc has failed.
Explanation A login attempt has succeeded from Connectivity management processor (CMP) in getting access as AAA succeeded
Explanation CoPP Initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message COPP-2-COPP_MTS_FAIL: Failed to do MTS operation: [chars]Explanation Failed to do MTS operation. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message COPP-2-COPP_NO_POLICY: Control-plane is unprotected.Explanation There isntanypolicyconfiguredtoprotectcontrol-plane.'
Recommended Action No action is required.
Error Message COPP-2-COPP_PROFILE_DIFF: CoPP Default Profile may have changed, please check the diffs using show copp diff profile <profile-typeExplanation CoPP Default Profile may have changed, please check the diffs using show copp diff profile <profile-type
Explanation Failed to alloc required memory. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message COPP-3-COPP_PPF_FAIL: Error during PPF operation: [chars]Explanation Failed to do PPF operation. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message COPP-3-COPP_PSS_FAIL: Error during PSS operation: [chars]Explanation Failed to do PSS operation. [chars] explains the reason for the failure.
Explanation COPP Service Disabled
Recommended Action No action is required.
Error Message COPP-5-COPP_ENABLED: COPP EnabledExplanation COPP Service nabled
Recommended Action No action is required.
Error Message COPP-5-COPP_INIT: COPP initializedExplanation CoPP policy has been attached to control plane interface.
Recommended Action No action is required.
Error Message COPP-6-COPP_POLICY_DETACHED: CoPP policy has been detached from control plane interface.Explanation CoPP policy has been detached from control plane interface.
Explanation Kernel coredump finishing on a module
Recommended Action No action is required.
Error Message CORE-DMON-2-MODULE_COREDUMP_STARTED: kernel coredump started on module:[dec]Explanation Credit Monitor application exited
Recommended Action No action is required.
Error Message CREDITMON-SLOT#-2-SYSERR_CREDITMON_MTS_INIT_ERR: [chars]Explanation Fibre-Channel Authentication failure on Port [chars].(Reason Code [chars] Detail [chars]). Please check password configurations and ensure appropriate security modes on this port as well as peer port
Recommended Action No action is required.
Error Message CTS-2-CTS_SAP_FAILED: SAP exchange failed on interface [chars]. (Reason: [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-CTS_SAP_REKEY_FAILED: SAP exchange failed on interface [chars]. (Reason: [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-DBG_INIT_FAILED: Debug Infrastructure Initialization failed ( [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-FC2_E_INIT_FAILED: Fibre-Channel Initialization of an E_Port failed ( [chars])Explanation CTS Manager has been unable to initialize with the FC-2 E-Port infrastructure.
Recommended Action No action is required.
Error Message CTS-2-FC2_F_INIT_FAILED: Fibre-Channel Initialization of an F_Port failed ( [chars])Explanation CTS Manager has been unable to initialize with the FC-2 F-Port infrastructure.
Recommended Action No action is required.
Error Message CTS-2-FC2_UNKNOWN_FRM_RECD_CRIT: Received an unexpected/unknown FC-2 frame on [chars]Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-FSMU_INIT_FAILED: State Machine Infrastructure Initialization failed ( [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-IPC_INIT_FAILED: IPC (Inter Process Communication) Initialization failed ( [chars])Explanation CTS Manager has been unable to initialize with the IPC infrastructure.
Recommended Action No action is required.
Error Message CTS-2-LICENSE_UNAVAILABLE: License:[chars] unavailable, service exitingExplanation License of [chars] is unavailable. Service will exit now
Recommended Action Please install the license file to continue using the feature.
Error Message CTS-2-MEM_FAILED: Memory operations failed File: [chars] Line [dec] for size [hex] bytesExplanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-POST_INIT_FAILED: Post-Initialization failed ( [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-PSS_INIT_FAILED: PSS Infrastructure Initialization failed ( [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-RBACL_ENFORCEMENT_FAILED: Failed to [chars] RBACL enforcement on [chars] %luExplanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-RBACL_LC_INSERT_FAILED: RBACL programming failed for inserted module [dec]Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-RBACL_TCAM_SPACE_NOT_ENOUGH: Not enough free space left on TCAMExplanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-RBACL_UNABLE_PARSE_ACE: Unable to parse RBACL ACE substring: [chars]Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-2-RBACL_UPDATE_FAILED: Failed to [chars] RBACL [chars]Explanation The system has detected an error.
Recommended Action No action is required.
Error Message CTS-5-CTS_IP_SGT_MAP_UPDATE: [chars] assigned SGT [chars]Explanation This message provides information about errors related to SSH.
Recommended Action Perform additional debugging to resolve the issue
Explanation DCEFIB failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'
Recommended Action No action is required.
Error Message DCEFIB-SLOT#-0-TIMER_INIT_FAILED: Timer subsystem initialization failed!Explanation DCEFIB failed to initialize timer library. This is a fatal error.
Explanation Memory allocation failed. This is a critical failure
Recommended Action No action is required.
Error Message DCEFIB-SLOT#-2-DCEFIB_RECOVERY_ERROR: Error in Recovery: [chars]Explanation DCEFIB failed to recover after a re-start. This is a fatal error.
Explanation DCEFIB has created its internal state stateless/stateful [chars].
Recommended Action No action is required.
Error Message DCEFIB-SLOT#-6-VDC_CREATED: VDC [dec] createdExplanation Request to create VDC [dec] in DCEFIB was successful.
Recommended Action No action is required.
Error Message DCEFIB-SLOT#-6-VDC_REMOVED: VDC [dec] RemovedExplanation DCEFIB has successfully removed VDC [dec] from its databases.
Explanation Memory allocation failed for size [dec] type [dec]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-2-INIT_FAILED: [chars]Explanation An error occurred during initialization. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation An error occurred while performing a CFS operation. [chars] indicates the CFS operation and the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-CLEAR_FAILED: [chars]Explanation An error occurred while clearing the session. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-COMMIT_FAILED: [chars]Explanation An error occurred while committing the database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-COMMIT_REJECTED: [chars]Explanation Commit request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-LOCK_FAILED: [chars]Explanation An error occurred while acquiring the lock. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-LOCK_REJECTED: [chars]Explanation Lock request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_ACTIVATION_FAILED: [chars]Explanation An error occurred while activating the merged database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_ACTIVATION_REJECTED: [chars]Explanation Merge activation request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_FAILED: [chars]Explanation An error occurred during merge operation. [chars] indicates the reason for failure.
Recommended Action Compare device-alias configuration with the other switches in the fabric, resolve the conflicts if any and commit the changes.
Error Message DEVICE-ALIAS-3-MERGE_MREQ_REJECTED: [chars]Explanation MREQ received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_MRESP_REJECTED: [chars]Explanation MRESP received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_VALIDATION_FAILED: [chars]Explanation An error occurred while validating the merged database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MERGE_VALIDATION_REJECTED: [chars]Explanation Merge validation request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-MTS_OPER_FAILED: [chars]Explanation An error occurred during MTS operation. [chars] indicates the MTS operation and the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-PSS_OPER_FAILED: [chars]Explanation An error occurred during PSS operation. [chars] indicates the PSS operation and the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-UNLOCK_FAILED: [chars]Explanation An error occurred while releasing the lock. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-UNLOCK_REJECTED: [chars]Explanation Unlock request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-VALIDATION_FAILED: [chars]Explanation An error occurred while validating the database. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-3-VALIDATION_REJECTED: [chars]Explanation Validation request received from remote switch is rejected. [chars] indicates the reason for failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation An error occurred while clearing the session. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-COMMIT_FAILED_INFO: [chars]Explanation An error occurred while committing the database. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-IMPORT_DEFINITION_CONFLICT: Fcalias [chars] could not be imported due to definition conflictExplanation Fcalias [chars] could not be imported due to definition conflict. Either there is already a device-alias configuration present with the same definition OR another VSAN specified in the import VSAN range has an fcalias with the same definition.
Recommended Action Resolve the conflict and issue the import command again.
Error Message DEVICE-ALIAS-6-IMPORT_MEMBER_TYPE_CONFLICT: Fcalias [chars] could not be imported due to having unsupported member typeExplanation Fcalias [chars] could not be imported due to having unsupported member types. Fcalias can be imported only if it has Port WWN based members..
Recommended Action Make sure that the fcalias has Port WWN based members and issue the import command again.
Error Message DEVICE-ALIAS-6-IMPORT_NAME_CONFLICT: Fcalias [chars] could not be imported due to name conflictExplanation Fcalias [chars] could not be imported due to name conflict. Either there is already a device-alias configuration present with the same name OR another VSAN specified in the import VSAN range has an fcalias with the same name.
Recommended Action Resolve the conflict and issue the import command again.
Error Message DEVICE-ALIAS-6-IMPORT_NUM_MEMBERS_CONFLICT: Fcalias [chars] could not be imported due to having unsupported number of membersExplanation Fcalias [chars] could not be imported due to having unsupported number of members. Fcalias can be imported only if it has exactly one member..
Recommended Action Make sure that the fcalias has exactly one member and issue the import command again.
Error Message DEVICE-ALIAS-6-LOCK_FAILED_INFO: [chars]Explanation An error occurred while acquiring the lock. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-MERGE_ACTIVATION_FAILED_INFO: [chars]Explanation An error occurred while activating the merged database. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-MERGE_VALIDATION_FAILED_BUSY: [chars]Explanation Merged database could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.
Error Message DEVICE-ALIAS-6-MERGE_VALIDATION_REJECTED_BUSY: [chars]Explanation Merged database received from the remote switch could not be validated as some of the applications returned busy. [chars] indicates information about the application returned busy. There is no user intervention necessary. The validation would be automatically retried after some time.
Error Message DEVICE-ALIAS-6-UNLOCK_FAILED_INFO: [chars]Explanation An error occurred while releasing the lock. [chars] indicates the additional information regarding failure.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DEVICE-ALIAS-6-VALIDATION_ABORTED: [chars]Explanation Local validation is aborted. [chars] indicates the reason why validation is aborted.
Explanation Online diagnostics ASICRegisterCheck test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-COMPACT_FLASH_FAIL: Module [dec] has failed test [chars] [dec] times on device Compact Flash due to error [chars]Explanation Online diagnostics CompactFlash test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-CRYPTO_DEVICE_FAIL: Module [dec] has failed test [chars] [dec] times on Crypto device due to error [chars]Explanation Online diagnostics CryptoDevice test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-FAN_MOD_FAIL: Module [dec] has failed test [chars] [dec] times on System Mgmt Bus for chassis [chars] instance [dec] due to error [chars] error number [hex]Explanation Online diagnostics SystemMgmtBus test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-MALLOC_FAILURE: Memory allocation failedExplanation Device Test process could not allocate memory
Recommended Action No action is required.
Error Message DEVICE_TEST-2-NVRAM_FAIL: Module [dec] has failed test [chars] [dec] times on device NVRAM due to error [chars]Explanation Online diagnostics NVRAM test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-POWER_SUPPLY_FAIL: Module [dec] has failed test [chars] [dec] times on System Mgmt Bus for chassis [chars] instance [dec] due to error [chars] error number [hex]Explanation Online diagnostics SystemMgmtBus test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-PRIMARY_BOOTROM_FAIL: Module [dec] has failed test [chars] [dec] times on device Primary BootROM due to error [chars]Explanation Online diagnostics PrimaryBootROM test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-PWR_MGMT_BUS_FAIL: Module [dec] has failed test [chars] [dec] times on device Power Mgmt Bus on slot [dec] due to error [chars] error number [hex]Explanation Online diagnostics PwrMgmtBus test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-RTC_FAIL: Module [dec] has failed test [chars] [dec] times on device RealTimeClock due to error [chars]Explanation Online diagnostics RealTimeClock test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-SECONDARY_BOOTROM_FAIL: Module [dec] has failed test [chars] [dec] times on device Secondary BootROM due to error [chars]Explanation Online diagnostics SecondaryBootROM test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-SPINE_CONTROL_BUS_FAIL: Module [dec] has failed test [chars] [dec] times on device Spine Control Bus on slot [dec] due to error [chars] error number [hex]Explanation Online diagnostics SpineControlBus test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-STANDBY_LOOPBACK_TEST_FAIL: Module [dec] has failed test [chars] [dec] times on [chars] [dec] due to error [chars]Explanation Online diagnostics StandbyFabricLoopback test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-TWOWIRE_STW_FAIL: Module [dec] has failed test [chars] [dec] times on Status Bus on slot [dec] due to error [chars]Explanation Online diagnostics Status bus test has failed
Recommended Action No action is required.
Error Message DEVICE_TEST-2-USB_FAIL: Module [dec] has failed test [chars] [dec] times on device USB due to error [chars]Explanation Device Test StandbyLoopback Test failed get vqi
Recommended Action No action is required.
Error Message DEVICE_TEST-3-STANDBY_TEST_GET_SPINE_FAIL: Standby test get spines failed due to error [hex]Explanation Device Test StandbyFabricLoopback Test get spine failed
Recommended Action No action is required.
Error Message DEVICE_TEST-3-STANDBY_TEST_INIT_FAIL: Init for standby test failed due to error [hex]Explanation Device Test StandbyFabricLoopback Test failed init process
Recommended Action No action is required.
Error Message DEVICE_TEST-3-STANDBY_TEST_MTS_FAIL: Mts Init for standby test failed due to error [hex]Explanation Device Test StandbyFabricLoopback Test failed mts init
Recommended Action No action is required.
Error Message DEVICE_TEST-3-STANDBY_TEST_SOCKET_FAIL: Standby test socket error [chars]: [hex]Explanation Device Test StandbyFabricLoopback Test Socket error
Explanation Device Test process could not create threads
Recommended Action No action is required.
Error Message DEVICE_TEST-4-TIMER_CREATE_FAIL: Timer creation failedExplanation Device Test process could not create timer
Recommended Action No action is required.
Error Message DEVICE_TEST-4-TIMER_START_FAIL: Timer start failedExplanation DFTM database doesn't have the interface.
Recommended Action No action is required.
Error Message DFTM-SLOT#-2-DFTM_INVALID_INTF_NUM: DFTM has invalid number of interfaces [dec] in the DBExplanation DFTM has invalid number of interfaces in the DB.
Recommended Action No action is required.
Error Message DFTM-SLOT#-2-DFTM_PC_NUM_MEMB_INVALID: DFTM recieved invalid number of PC members [dec] from ELTMExplanation DFTM recvd invalid number of PC members from ELTM.
Recommended Action No action is required.
Error Message DFTM-SLOT#-2-DFTM_VLAN_NOT_FOUND: VLAN [dec] not found in DFTM database [chars]Explanation DFTM failed to program BDDB Entry
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_BDT_PROG_FAILED: DFTM failed to program BD Table EntryExplanation DFTM failed to program BD Table Entry
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_IFIDX_INVALID_PORT_LAYER: Invalid Port Layer Received for interface: [chars]Explanation Invalid Port Layer Received for interface
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_IFIDX_INVALID_PORT_MODE: Invalid Port Mode Received for interface: [chars]Explanation Invalid Port Mode Received for interface
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_IFIDX_INVALID_PORT_TYPE: Invalid Port Type Received for interface: [chars]Explanation Invalid Port Type Received for interface
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_IFIDX_TYPE_ERROR: Failed to get type for interface: [chars]Explanation Failed to get type for the interface
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_L2L3CT_PROG_FAILED: DFTM failed to program L2L3 Consistency Table EntryExplanation DFTM failed to program L2L3 Consistency Table Entry
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_MFT_PROG_FAILED: DFTM failed to program Multicast FTag Table EntryExplanation DFTM failed to program Multicast Ftag Table Entry
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_SDT_PROG_FAILED: DFTM failed to program SGT DGT Table EntryExplanation DFTM failed to program SGT DGT Table Entry
Recommended Action No action is required.
Error Message DFTM-SLOT#-3-DFTM_VTT_PROG_FAILED: DFTM failed to program VLAN Translation Table Entry for vlan [dec], xlt_vlan [dec] on fe [dec]Explanation DHCP snoop process did an abnormal exit
Recommended Action No action is required.
Error Message DHCP_SNOOP-2-INITFAIL: DHCP Daemon Initialization failed: [chars]Explanation DHCP Daemon Initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message DHCP_SNOOP-2-PSSERROR: [chars]Explanation DHCP Daemon encountered a PSS error. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message DHCP_SNOOP-2-REGPARTREE: Unable to register par tree: [chars]Explanation Could not register par tree. [chars] explains the reason for the failure.
Explanation DHCP Daemon is out of dynamic memory. [chars] specifies the context where the failure occurred.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-ASSERTION_FAILED: [chars]:[dec]Explanation DHCP Snoop process has hit an assert condition at file [chars] line number [dec]
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-DHCPDENIEDARP: ARP frame denied due to DHCP snooping binding on interface [chars] vlan [dec] sender mac [chars] sender ip [chars] target mac [chars] target ip [chars].Explanation [chars] identifies interface and [dec] identifies the vlan on which ARP packets have been denied. [chars] identifies sender mac and [chars] identifies the sender ip. [chars] identifies the target mac and [chars] identifies the target ip.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-DHCPRATELIMIT: Interface [chars] has been error disabled due to excessive ingress rate [dec] of DHCP packets.Explanation [chars] identifies the interface which has been error disabled due to excessive ingress rate [dec].
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-HWPGMFAILURE: Hardware programming has failed: [chars]Explanation Hardware programming has failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-INVDHCPPKTS: Validation errors while processing DHCP packet received on interface [chars] vlan [dec] Reason:[chars]. Dropping the packetExplanation Validation errors DHCP packet receieved on the interface [chars] vlan [[dec]]. Reason:[chars]
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-MTSERROR: [chars]Explanation DHCP Daemon encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-PKTDROP: Packet dropped. Reason - [chars]Explanation Dropping the packet. [char] identifies the reason.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-PKTRECVFAIL: Failed to receive packet - [chars]Explanation Failed to receive packet. [char] identifies the reason.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-PKTSENDFAIL: Failed to send packet, - [chars]Explanation Failed to send packet. [char] identifies the reason.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-SOCKBINDFAIL: Failed to bind to raw socket - [chars]Explanation Failed to bind to socket. [char] identifies the reason.
Recommended Action No action is required.
Error Message DHCP_SNOOP-3-SOCKOPENFAIL: Failed to open socket for receiving DHCP packets - [chars]Explanation An attempt to open a socket for receiving DHCP packets failed. [char] identifies the reason.
Explanation Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-ACL_PERMIT: [dec] ARP messages ([chars]) on [chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])Explanation Packet-count [dec] ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-DHCP_SNOOPING_DENY: [dec] Invalid ARP messages ([chars]) on [chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])Explanation Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-DHCP_SNOOPING_PERMIT: [dec] ARP messages ([chars]) on [chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])Explanation Packet-count [dec] ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-ERROR_DISABLED: Interface [chars] has moved to error disabled state due to excessive rate [dec] of ingress ARP packetsExplanation Interface [chars] has moved to error disabled state due to excessive rate [dec] of ingress ARP packets
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-INVALID_ARP: [dec] Invalid ARP messages ([chars]) on [chars], vlan [dec]. ([[chars]/[chars]/[chars]/[chars]/[chars]])Explanation Packet-count [dec] Invalid ARPs (arp-type [chars]) on interface [chars], vlan [dec]. ([sender-mac [chars]/sender-ip [chars]/ target-mac [chars]/target-ip [chars]/ time-of-day [chars]])
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-SMARTRELAYMAXIPADDR: Smart relay is supported only on first [dec] IP addresses of the interface [chars].Explanation There are more than SMARTRELAYMAXIPADDR addresses configured on the interface. [dec] is the number of IP addresses with which smart relay supported [chars] identifies the interface. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-SMARTRELAYMAXLMT: Smart relay MAX limit [dec] reached. All subsequent DHCP packets will be relayed with primary address of inbound interface as relay agent address.Explanation Smart relay MAX limit reached. [dec] is the number of smart relay bindings This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-4-SUBNETBCASTRELAYMAXIPADDR: subnet-broadcast relay is supported only on first [dec] IP addresses of the interface [chars].Explanation There are more than SUBNETBCASTRELAYMAXIPADDR addresses configured on the interface. [dec] is the number of IP addresses with which subnet-broadcast relay supported [chars] identifies the interface. This is an informational message.
Explanation Dynamic ARP Inspection was disabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DAIVLANENABLE: DAI enabled on vlan [dec]Explanation Dynamic ARP Inspection was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPBINDSYNC: Binding entry with MAC [chars] interface [chars] VLAN [dec] IP address [chars] and lease time [dec] secs is synced.Explanation Binding entry identified by [chars] has been synced. [chars] identifies the interface. [dec] identifies the VLAN. [chars] identifies IP address. [dec] identifies the lease time in secs. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPEXIT: DHCP Daemon shutting down gracefully.Explanation DHCP Daemon is shutting down gracefully. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPHOSTADD: A new Host is [chars] connected to interface [chars] in VLAN [dec] and is allocated IP address [chars] for [dec] secs.Explanation A Host identified by [chars] has been added. [chars] identifies the interface. [dec] identifies the VLAN. [chars] identifies IP address. [dec] identifies the lease time in secs. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPLEASEEXPIRE: Lease expired for host [chars] having IP address [chars] connected to interface [chars] in VLAN [dec] for lease [dec] secs.Explanation The lease for host identified by [chars] with IP address [chars] connected to interface [chars] in VLAN [dec] with lease [dec] has expired.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPPERMITTEDARP: ARP frame permitted due to DHCP snooping binding on interface [chars] vlan [dec] sender mac [chars] sender ip [chars] target mac [chars] target ip [chars].Explanation [chars] identifies interface and [dec] identifies the vlan on which ARP packets have been permitted. [chars] identifies sender mac and [chars] identifies the sender ip. [chars] identifies the target mac and [chars] identifies the target ip.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPPKTFWD: Gracefully forwarding DHCP packet. Reason: [chars]Explanation Gracefully forwarding DHCP packet. reason [chars]
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-DHCPUP: DHCP Daemon Up.Explanation DHCP Daemon was created successfully and is up and running. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-INFO: [chars]Explanation An event during switchover. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-INTFDISABLE: IP Src Guard disabled on intf [chars]Explanation IP Src Guard was disabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-INTFENABLE: IP Src Guard enabled on intf [chars]Explanation IP Src Guard was enabled on a given intf. [chars] is the intf-ID string that identifies the intf. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-NONDHCPPKTFWD: Non DHCP packet with src port:[dec] dst port:[dec] on intf:[chars] vlan:[dec]. Forwarding on [chars]Explanation Non DHCP packet arrived with UDP src/dst ports [dec], [dec] on interface [chars], vlan [dec]. Forwarding the packet on [chars]
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-OPT82INSTFAIL: [chars] [chars]Explanation Insertion of Option82 suboptions failed. [chars] tells the failure. [chars] explains the reason for failure. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-VLANDISABLE: DHCP Snooping disabled on vlan [dec]Explanation DHCP Snooping was disabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.
Recommended Action No action is required.
Error Message DHCP_SNOOP-6-VLANENABLE: DHCP Snooping enabled on vlan [dec]Explanation DHCP Snooping was enabled on a given vlan. [dec] is the VLAN-ID that identifies the vlan. This is an informational message.
Explanation Bootup Test completed
Recommended Action Nothing to be done if the test reports SUCCESS otherwise copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information
Error Message DIAGCLIENT-2-EEM_ACTION_HM_SHUTDOWN: Test <[chars]> has been disabled as a part of default EEM actionExplanation Informational Syslog
Recommended Action No action is required.
Error Message DIAGCLIENT-2-PSS_READ_FAILURE: Read from PSS failed on Module <[dec]>Explanation Read operation from PSS store failed
Recommended Action No action is required.
Error Message DIAGCLIENT-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]>Explanation A Health Monitoring Test has reported failure
Recommended Action Ensure the line card is firmly in the slot, reseat if necessary, and attempt to run the test again if the line card is not seated properly in the slot. If the line card was properly seated in the slot, copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information.
Error Message DIAGCLIENT-3-ONDEMAND_FAIL_EXCESS: Module <[dec]> Test <[chars]> has failed more than <[dec]> number of timesExplanation Ondemand test has failed more than configured number of times
Recommended Action Copy the error message exactly as it appears on the console, gather the output of show tech-support, and contact your Cisco technical support representative with the gathered information
Explanation Informational Syslog
Recommended Action No action is required.
Error Message DIAGCLIENT-4-MTS_SEND_FAILURE: MTS send failed, mts_opc: [chars], dest slot: [dec], dest SAP: [dec], error-id: [hex]Explanation DiagClient process could not allocate memory
Recommended Action No action is required.
Error Message DIAGCLIENT-5-DIAG_SCHED_COMPLETE: Module <[dec]> Test <[chars]> has completed Scheduled TestingExplanation A scheduled Test was completed
Recommended Action No action is required.
Error Message DIAGCLIENT-5-ONDEMAND_FAIL: Module <[dec]> Test <[chars]> has failed in Test_Iteration <[dec]>Explanation The specified test has reported FAILURE in this Iteration
Recommended Action No action is required.
Error Message DIAGCLIENT-5-ONDEMAND_SUCCESS: Module <[dec]> Test <[chars]> has completed successfully in Test_Iteration <[dec]>Explanation The specified test has reported SUCCESS in this Iteration
Recommended Action No action is required.
Error Message DIAGCLIENT-5-PER_PORT_TEST_FAIL: Module <[dec]> Test <[chars]> has failed on Ports <[chars]> Please use 'show diagnostic result <target>' to see test resultsExplanation MTS send reports failure
Recommended Action No action is required.
Error Message DIAGMGR-2-PSS_DELETE_FAILURE: Read from PSS failed on Module <[dec]>Explanation Read operation from PSS store failed
Recommended Action No action is required.
Error Message DIAGMGR-2-PSS_WRITE_FAILURE: Write to PSS failed on Module <[dec]>Explanation A major error was detected during diagnostic testing
Recommended Action Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information.
Error Message DIAGMGR-3-DIAG_MINOR_DEFECT: Module <[dec]> Test <[chars]> detected a Minor Error Please use 'show diagnostic result <target>' to see test resultsExplanation A minor error was detected during diagnostic testing
Recommended Action Re-seat the card and retry the test. If the same result occurs after reseating the card and retrying the test, copy the error message exactly as it appears on the screen and gather the output of show tech-support and any other relevant information. Contact your technical support representative with the gathered information
Error Message DIAGMGR-3-GET_CURR_SLOT_FAIL: Failed to get the current slot for the process. Error:[chars]Explanation The process initialization failed to get the current slot.
Recommended Action This is an informational message stating that a process initialization failure.
Explanation The process received an offline event for the slot it is running. Ignoring it.
Recommended Action This is an informational message stating that an unexpected event has been encountered.
Error Message DIAGMGR-4-DISRPT_TST_START: Starting Test <[chars]> on Module <[dec]> is DisruptiveExplanation Starting a Disruptive Test can disturb the system's normal functionality
Recommended Action Reset target module
Error Message DIAGMGR-4-FIXED_INTRVL_CHANGED: The users are not allowed to change monitoring interval of Test <[chars]>Explanation The specified health monitoring test interval is not user-configurable and therefore cannot be changed
Recommended Action Nothing. The specific health monitoring interval is not user- configurable by design so nothing can be done to change the interval
Explanation Current Diagnostic BootUp Level being configure or changed
Recommended Action No action is required.
Error Message DIAGMGR-5-CALLOC_FAILURE: Memory allocation failureExplanation Memory allocation in a call to malloc/calloc has failed
Recommended Action No action is required.
Error Message DIAGMGR-5-CHANGE_ALWAYS_HM: Health Monitoring test <[chars]> in Module <[dec]> is a must run and cannot be modifiedExplanation The specified health monitoring test must be run and cannot be disabled
Recommended Action Nothing. The specific health monitoring test cannot be disabled by design. The system is working properly.
Error Message DIAGMGR-5-HM_START: Health monitoring test <[chars]> for Module <[dec]>Explanation Health Monitoring Test started
Recommended Action No action is required.
Error Message DIAGMGR-5-HM_STOP: Disabling health monitoring test <[chars]> for Module <[dec]>Explanation Health Monitoring Test has been stopped It can be enabled through the diagnostic monitor..... command
Recommended Action No action is required.
Error Message DIAGMGR-5-INTRVL_INCORRECT: Monitoring Interval is less than minimum of [dec] seconds required for Module <[dec]> test <[chars]>Explanation Health Monitoring cannot be enabled for the specified test because the interval for the test has been incorrectly set
Recommended Action The system is working properly and no action is required. If you want to specify a smaller testing interval, the error message text provides the lowest possible configurable interval for the specified monitoring interval
Error Message DIAGMGR-5-MODULE_MISSING: Diagnostic command issued on non-existing Module <[dec]>Explanation A line card could not be located in a slot where a diagnostic action was requested
Recommended Action Ensure the targeted line card is properly seated in the specified slot. If the line card is properly seated, ensure the correct slot was indicated in the command-line interface. If the line card is well-seated and the correct slot was specified, copy the error message exactly as it appears on the screen as well as the output of show tech-support and paste the output into a separate file. Contact your technical support representative with the gathered information
Error Message DIAGMGR-5-NONHM_AS_HM: The Test <[chars]> cannot be used as health monitoring testExplanation Non-HM test cannot be scheduled to run as a Health Monitoring test
Explanation The diagnostic tests did not detect any error on the card.
Recommended Action This is an informational message stating that the line card passed the diagnostic tests.
Error Message DIAGMGR-6-BOOTUP_TEST_STARTED: Module <[dec]>: Running [chars] DiagnosticsExplanation Random Number genration failed in FIPS module
Recommended Action No action is required.
Error Message DIAG_PORT_LB-2-LCM_RESP_SEND_FAILURE: LC Inserted request response send to Module Manager failed. Error:[chars]Explanation Failed to send the response for LC insertion to Module Manager.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-2-LIF_GET_ERROR: [chars]([dec]) [chars] Error:[chars]Explanation Port Loopback test process failed to get Diagnostic LIF id
Recommended Action No action is required.
Error Message DIAG_PORT_LB-2-MALLOC_FAILURE: [chars]([dec]) Memory allocation failed.Explanation Port Loopback test process could not allocate memory
Recommended Action No action is required.
Error Message DIAG_PORT_LB-2-PORTLOOPBACK_TEST_FAIL: Module:[dec] Test:PortLoopback failed [dec] consecutive times. Faulty module:[chars] [chars] Error:[chars]Explanation PortLoopback test failed on the module consecutively
Recommended Action No action is required.
Error Message DIAG_PORT_LB-2-PROC_INIT_FAILURE: [chars]([dec]) [chars] Error:[chars]Explanation Port Loopback test process failed in process initialization
Recommended Action No action is required.
Error Message DIAG_PORT_LB-2-REWRITE_ENGINE_LOOPBACK_TEST_FAIL: Module:[dec] Test:RewriteEngine Loopback failed [dec] consecutive times. Faulty module:[chars] [chars] Error:[chars]Explanation Rewrite Engine Loopback test failed on the module consecutively
Explanation Forwarding path setup for port loopback tests failed
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-DIAG_PKT_SEND_FAILURE: [chars]([dec]) [chars]. Error:[chars]Explanation Port Loopback test process failed to send loopback packets.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-FSM_LIB_ERROR: [chars]([dec]) [chars]. Error:[chars]Explanation Port Loopback test process failed in MTS API.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-GET_DIAG_BD_FAIL: [chars]([dec]) Failed to get the BD for Diag VLAN:[dec]. Error:[chars].Explanation Failed to get the BD corresponding to the Diag VLAN
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-IFINDEX_LIB_FAILURE: [chars]([dec]) [chars] [chars]:[hex] [chars] [chars]Explanation Port Loopback test process failed in if_index library API
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-INVALID_TEST_REQUEST: [chars]([dec]) [chars]:[dec]Explanation Port Loopback test process failed to get test request info.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-INVALID_TEST_RUN: [chars]([dec]) [chars]:[dec]Explanation Port Loopback test process failed to get the current test run information
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-PDB_LIB_API_ERROR: Failed to [chars]. Error:[dec].Explanation The port loopback test was not able to get chassis info
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-PIXM_LIB_ERROR: [chars]([dec]) Failed to convert [chars]:[hex] to [chars]. Error:[chars]Explanation Port Loopback test process failed to convert port ifindex <-> port index.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-PORT_CLIENT_LIB_ERROR: [chars]([dec]) [chars]. Error:[chars]Explanation Port Loopback test process failed in Port Client API.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-RESULT_ADD_FAILURE: [chars]([dec]) [chars]:[dec]Explanation Port Loopback test process failed to add the port test result
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-RESULT_SEND_FAILURE: [chars]([dec]) [chars]Explanation Port Loopback test process failed to send the test results
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-RW_ENGINE_LOOPBACK_TEST_SPINE_PATH_FAIL: Module:[dec] Test:RewriteEngine Loopback Spine path:[dec] failed [dec] consecutive times. Error:[chars]Explanation Rewrite Engine Loopback test failed on the spine path consecutively
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-SOCKET_ERROR: [chars]([dec]) [chars] Error:[chars]Explanation Port Loopback test process failed in socket operations
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-STATS_LIB_ERROR: [chars]([dec]) [chars]:[dec]Explanation Port Loopback test process failed in stats infra lib API.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-TEST_RES_SEND_FAIL: Failed to send [chars] test results back to Diagnostics Infrastucture. Error:[chars].Explanation The port loopback test was not able to send the test results
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-TIMER_LIB_ERROR: [chars]([dec]) [chars]Explanation Port Loopback test process timer handling failure.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-VLAN_ERROR: [chars]([dec]) [chars] Error:[chars]Explanation Port Loopback test process failed to get Diagnostic VLAN info
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-VQI_GET_FAIL: Failed to get the Diag VQi from XBM. Error:[chars]Explanation Rewrite Engine Loopback test failed to get the Diag VQi from XBAR Mgr
Recommended Action No action is required.
Error Message DIAG_PORT_LB-3-XBM_CFG_REQ_FAIL: Failed to conigure the XBAR mask while running the RewriteEngineLoopback test. Error:[chars]. Module:[dec] could have gone offlineExplanation Rewrite Engine Loopback test failed to set the XBAR mask while running the test. The target module could have gone offline
Explanation Port Loopback test process failed in MTS API.
Recommended Action No action is required.
Error Message DIAG_PORT_LB-4-PORT_CFG_REQ_SEND: [chars]([dec]) Failed to send request to configure port ifindex:[dec] for port loopback testExplanation Failed to configure/restore the port to do/cleanup port loopback testing
Explanation DIAG_PORT_LB Service Disabled
Recommended Action No action is required.
Error Message DIAG_PORT_LB-5-DIAG_PORT_LB_ENABLED: DIAG_PORT_LB EnabledExplanation A New N-Port has come up which is zoned in the same zone as the Server
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_ERR_DMM_NEW_NPORT_STG_ZONE: Job Id:%Ld VSAN :[dec] New N-Port FCID :[hex] Storage FCID:[hex] are in the same zone. ALERT!!Explanation A New N-Port has come up which is zoned in the same zone as the Storage
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_ERR_DMM_SRVR_RSCN: Job Id:%Ld Server N-Port pWWN:0x%Lx [chars]Explanation An RSCN event was received for the Server associated with a Job
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_ERR_DMM_STG_RSCN: Job Id:%Ld N-Port pWWN:0x%Lx Storage:[chars] [chars]Explanation An RSCN event was received for the Storage associated with a Job
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_COMPLETE: Job Id:%Ld NumSession:[dec]Explanation Event indicating the completion of a Data Migration Job
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_ERROR_LOST_SSM_PEER_CONNECTION: Job Id:%Ld NumSession:[dec]Explanation Event indicating the Suspension of Data Migration Job due to loss in ip connectivity to peer ssm
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_ERROR: Job Id:%Ld NumSession:[dec]Explanation Event indicating the Suspension of Data Migration Job
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_FINISH: Job Id:%Ld NumSession:[dec]Explanation Event indicating Finish-request for a Method-2 Data Migration Job
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_START: Job Id:%Ld NumSession:[dec]Explanation Event indicating the start of a Data Migration Job
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_STOP: Job Id:%Ld NumSession:[dec]Explanation Event indicating that the Data Migration Job was stopped by Administrator
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_TCP_CONNECTION_DOWN: Job Id:%Ld lost connection to peer [chars]. Job may be RESETExplanation Event indicating IP Connectivity loss to peer SSM. Affected Job maybe be RESET
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_COMPLETE: Job Id:%Ld NumSession:[dec]Explanation Event indicating the completion of a Data Migration Job Verification
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_ERROR: Job Id:%Ld NumSession:[dec]Explanation Event indicating the Suspension of Data Migration Job Verification due to an error
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_START: Job Id:%Ld NumSession:[dec]Explanation Event indicating the start of a Data Migration Job Verification
Recommended Action No action is required.
Error Message DMM-SLOT#-5-LOG_EV_DMM_JOB_VERIFY_STOP: Job Id:%Ld NumSession:[dec]Explanation Event indicating the Suspension of Data Migration Job Verification by the user
Explanation The system failed to create the Dot1x process
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Dot1x and SPAN Dest ports are mutually exclusive features.
Recommended Action Disable SPAN destination port configuration first before reconfiguring Dot1x on the port.
Error Message DOT1X-3-INVALID_INPUT: Invalid on interface [chars].Explanation The Dot1x interface parameter is out of the specified range or is invalid.
Recommended Action Refer to the CLI help documentation to determine the valid 802.1x parameters.
Error Message DOT1X-3-MEM_UNAVAIL: perform the 802.1X action.Explanation Insufficient system memory is available to perform the Dot1x Authentication.
Recommended Action Reduce other system activity to ease memory demands. If conditions warrant, upgrade to a larger memory configuration.
Error Message DOT1X-3-NOT_DOT1X_CAPABLE: [chars].Explanation Dot1x Authentication can only be enabled on physical Ethernet interfaces.
Recommended Action Enable Dot1x Authentication on physical Ethernet interfaces only.
Error Message DOT1X-3-SM_INIT: Internal error while initializing state machine [chars], state [chars]: [chars]Explanation An attempt was made to initialize an invalid state machine.
Explanation An attempt was made to post an event to a state machine that is invalid for the current state.
Recommended Action Initialize dot1x state machine
Error Message DOT1X-4-MAB_DISABLED_ON_PCM: Interface [chars] is a member of portchannel, MAB is not supported on this portExplanation MAB is not supported on portchannel member port
Recommended Action To enable MAB make sure that port is not member of portchannel
Error Message DOT1X-4-MAB_DISABLED: Interface [chars] is in Trunk mode, MAB is not supported on this portExplanation MAB is not supported on Trunk port
Recommended Action To enable MAB make sure that port is not in trunk mode
Error Message DOT1X-4-MULTIHOST_ON_PCM: Interface [chars] is a member of portchannel, dot1x host mode will be multi-host and changing it to single-host mode won't be supportedExplanation Current Port is a member of portchannel, so dot1x host mode has to be in multi-host mode.
Recommended Action To change host mode, ensure that port is not a member of portchannel
Error Message DOT1X-4-PSEC_ON_PCM: Interface [chars] is a member port or portchannel interface with port security configrationExplanation Dot1x is not supported on member ports or port channel with port security configuration
Recommended Action Remove port security configuration on the member port or port channel interface
Error Message DOT1X-4-STOPPED: Event [chars] ignored because the state machine is stopped: [chars] [chars]Explanation An attempted was made to post an event to a state machine that has already been stopped.
Recommended Action An internal error has occurred with the state machine. The traceback should indicate the guilty party.
Error Message DOT1X-4-TO_MULTIHOST: Interface [chars] is in trunk mode, dot1x host mode will be multi-host and changing it to single-host mode won't be supportedExplanation Current Port is in trunk mode, so dot1x host mode has to be in multi-host mode.
Recommended Action To change host mode, ensure that port is not in trunk mode
Explanation Dot1x Service Disabled
Recommended Action No action is required.
Error Message DOT1X-5-DOT1X_ENABLED: dot1x EnabledExplanation Dot1x Service Enabled
Recommended Action No action is required.
Error Message DOT1X-5-INVALID_EAPOL: packet body length [dec] interface [chars] MTU [dec]Explanation 802.1X received invalid EAPOL packet
Recommended Action Verify source of EAPOL packets
Error Message DOT1X-5-INVALID_MAC: broadcast or multicast mac address) [chars] is trying to authenticate.Explanation Authentication using 802.1x is not allowed for zero, broadcast, and multicast source MAC addresses.
Recommended Action Connect a Dot1x supported Host to the Dot1x enabled port.
Error Message DOT1X-5-SECURITY_VIOLATION: New MAC address [chars] is seen on interface [chars] in [chars] modeExplanation The port on the interface specified in the error message is configured in single host mode. Any new host that is detected on the interface is treated as a security violation. The port has been Error disabled.
Recommended Action Ensure that the port is configured to use only one host. Enter the <Cmd>shutdown<Cmd> followed by <CmdBold>no shutdown<CmdBold> command to restart the port.
Error Message DOT1X-5-SESSION_CREATION: Dot1x authentication session initiated in interface [chars] using authentication method [chars]Explanation Dot1x authentication session has been created after successful authentication of supplicant
Recommended Action No action is required.
Error Message DOT1X-5-SESSION_TERMINATION: Dot1x authentication session in interface [chars] using authentication method [chars] is terminated because of [chars] and port moved to [chars] stateExplanation Dot1x authentication session has been terminated
Recommended Action No action is required.
Error Message DOT1X-5-STATUS: Dot1x interface [chars] status changed from [chars] to [chars]Explanation Dot1x authenticator has changed its internal state
Explanation Memory allocation failed for size [dec] for [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-2-DPVM_DUPL_REJECT: [chars]Explanation An error occured during an DPVM database operation. [chars] indicates the reason for the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-3-DDAS_MODE_INVALID: [chars]Explanation DDAS mode Invalid. [chars]
Recommended Action Flip DDAS mode
Error Message DPVM-3-INIT_FAIL: [chars]Explanation An error happened during DPVM Initialization. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-3-MTS_ERR: [chars]Explanation An error occured in processing of an MTS message. [chars] indicates the error that occured
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message DPVM-3-PSS_ERR: [chars]Explanation An error occured during an DPVM PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Activation of DPVM device mappings failed due to [chars]
Recommended Action Correct the error and reactivate database again
Error Message DPVM-4-FEATURE_DISABLED: [chars]Explanation DPVM is available and enabled now
Recommended Action No action is required.
Error Message DPVM-6-INFO: [chars]Explanation An event happened that affects DPVM. [chars] indicates the event
Explanation Invalid ftag is received from remote
Recommended Action No action is required.
Error Message DRAP-4-DRAP_INVALID_SWITCH_ID: Invalid switch-id [dec] receivedExplanation Invalid switch-id is received from remote
Recommended Action No action is required.
Error Message DRAP-4-DRAP_LINK_BRINGUP_STALLED: Link bringup stalled due to conflictsExplanation Resolving Collision for switch-id
Recommended Action No action is required.
Error Message DRAP-6-DRAP_NEW_SWITCH_ID: New switch-id [chars] receivedExplanation Dstats process pss initialization failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Explanation Dstats process pss create runtime database failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_DELETE_FAIL: pss delete runtime entry key:[hex] failed due to error: [hex]Explanation Dstats process pss delete runtime entry key [hex] failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_MAX_KEY_FAIL: pss set runtime max key failed due to error: [hex]Explanation Dstats process pss set runtime max key failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_MAX_VALUE_FAIL: pss set runtime max value failed due to error: [hex]Explanation Dstats process pss set runtime max value failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_OPEN_FAIL: pss open runtime database failed due to error: [hex]Explanation Dstats process pss open runtime database failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_RELOAD_FAIL: pss reload runtime database failed due to error: [hex]Explanation Dstats process pss reload runtime database failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_SNAPSHOT_DEBUG_FAIL: pss snapshot runtime debug to uri:[chars] failed due to error: [hex]Explanation Dstats process pss snapshot of runtime debug to uri [string] failed due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_SNAPSHOT_FAIL: pss snapshot runtime to uri:[chars] failed due to error: [hex]Explanation Dstats process pss snapshot of runtime to uri [string] failed due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Error Message DSTATS-3-PSS_STORE_FAIL: pss store runtime entry key:[hex] val:[hex] failed due to error: [hex]Explanation Dstats process pss store runtime entry key [hex] value [hex] failure due to error [hex].
Recommended Action Collect more information using command 'show flash'. See pss system error codes for reason.
Explanation ELTM hit a internal error. Collect show tech-support eltm for futher analysis.
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_INTERNAL_ERROR: Internal error: [chars], collect output of show tech-support eltmExplanation ELTM hit a internal error. Collect show tech-support eltm for futher analysis.
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_INTF_NOT_FOUND: Interface [chars] not found in ELTM database [chars]Explanation ELTM database doesn't have the interface.
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_INTF_NOT_SUPP: Interface [chars] not supported by ELTM [chars]Explanation ELTM doesn't support the interface for the specified operation
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_INTF_TO_LTL: Failed to get LTL for interface [chars] return status [chars]Explanation ELTM Failed to get LTL for interface. Packets received on this interface might not be handled correctly by the forwarding engine
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_INTF_TO_SLOT: Failed to get slot for interface [chars] return status [chars]Explanation ELTM Failed to get Slot for interface. Port-channels and L2 Learning might be effected
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_L2_LIF_ALLOC_FAIL_INTF: Failed to allocate L2 LIF entries in forwarding engine for interfac [chars]Explanation ELTM Failed to allocate L2 LIF entries in forwarding engine. This will effect Layer 2 and Layer 3 forwarding for the interface
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_L2_LIF_ALLOC_FAIL_VDC: Failed to allocate L2 LIF entries in forwarding engineExplanation ELTM Failed to allocate L2 LIF entries in forwarding engine. This will effect Layer 2 and Layer 3 forwarding in this VDC
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_L3_INGRESS_LIF_ALLOC_FAIL_INTF: Failed to allocate L3 Ingress LIF entries in forwarding engine for interfac [chars]Explanation ELTM Failed to allocate L3 Ingress LIF entries in forwarding engine. This will effect Layer 3 forwarding for the interface
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_RSVD_VLAN: Failed to get the reserved vlans. Failed with error [chars]Explanation ELTM Failed to get the reserved vlan's. This will effect multicast forwarding on SVI interfaces
Recommended Action No action is required.
Error Message ELTMC-SLOT#-2-ELTMC_VLAN_INTERNAL_ERROR: Internal error: VLAN [dec]:[chars], collect output of show tech-support eltmExplanation ELTM hit a internal error. Collect show tech-support eltm for futher analysis.
Explanation ELTM hit a internal error. Collect show tech-support eltm for futher analysis.
Recommended Action No action is required.
Error Message ELTM-2-INTERNAL_ERROR: Internal error: [chars], collect output of show tech-support eltmExplanation ELTM hit a internal error. Collect show tech-support eltm for futher analysis.
Recommended Action No action is required.
Error Message ELTM-2-INTF_NOT_FOUND: Interface [chars] not found in ELTM database [chars]Explanation ELTM database doesn't have the interface.
Recommended Action No action is required.
Error Message ELTM-2-INTF_NOT_SUPP: Interface [chars] not supported by ELTM [chars]Explanation ELTM doesn't support the interface for the specified operation
Recommended Action No action is required.
Error Message ELTM-2-INTF_TO_LTL: Failed to get LTL for interface [chars] return status [chars]Explanation ELTM Failed to get LTL for interface. Packets received on this interface might not be handled correctly by the forwarding engine
Explanation Recently applied Multicast config on the interface was unsuccessful, so reverting to the old state (before config)
Explanation No action is required.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Explanation Failure of host addition/deletion to/from pbacl group
Recommended Action Please verify the addition/deletion of the host using the cli show object-group. If it was a delete request that failed, manual deletion of the host from the group is recommended
Explanation Service EOU Disabled
Recommended Action No action is required.
Error Message EOU-5-L2NAC_ENABLED: EOU EnabledRecommended Action No action is required.
Error Message EOU-6-AUTHTYPE: Authtype: ip: [chars] Authtype:[chars]Explanation Authentication type
Recommended Action No action is required.
Error Message EOU-6-BAD_PKT: Bad Packet: ip: [chars] Why: [chars]Explanation Bad Packet because of reason specified
Recommended Action No action is required.
Error Message EOU-6-CTA: CTA: ip: [chars] status(detected/not detected): [chars]Explanation CTA detected or not
Recommended Action No action is required.
Error Message EOU-6-IDENTITY_MATCH: Identity Match: ip: [chars] Policy: [chars]Explanation Identity Matched or not
Recommended Action No action is required.
Error Message EOU-6-PBACL_APPLICATION_STATUS: [chars] of host [chars] to/from pbacl group [chars] succeededExplanation Status of host addition/deletion to pbacl group
Recommended Action No action is required.
Error Message EOU-6-POLICY: Policy on ip: [chars]: [chars]: [chars]Recommended Action No action is required.
Error Message EOU-6-POSTURE: Posture:ip: [chars] Status: [chars], Interface: [chars]Recommended Action No action is required.
Error Message EOU-6-SESSION: Session ip: [chars] Action:[chars], Interface: [chars]Recommended Action No action is required.
Error Message EOU-6-SOCKET: Service eou on port: [dec]Explanation Eou using above port
Recommended Action No action is required.
Error Message EOU-6-SQ_EAP_MSG: Status Query: ip: [chars] status: [chars]Explanation Status query state
Recommended Action No action is required.
Error Message EOU-6-UNKN_EVENT_ERR: Unknow Event Err: ip: [chars] Message: [chars]Explanation Error due to unknown event
Recommended Action No action is required.
Error Message EOU-6-VERSION_MISMATCH: Eou version mismatch ip: [chars] and version [dec]Explanation Eou service disabled on interface
Recommended Action No action is required.
Error Message EOU-7-EOU_ENABLED_INTF: eou enabled on interface [chars]Explanation Install all epld did not upgrade Active Supervisor.
Explanation Trunk protocol failed
Recommended Action 'show epp internal event-history err' will indicate the errors encountered
Error Message EPP-5-EPP_LOOPBACK: Interface [chars] is looped back to the same switchExplanation The interface is looped back to another interface on the same switch
Recommended Action Check the connectivity of this interface and ensure that it is connected to another switch
Explanation Failed to configure MACs
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_INVALID_VLAN: Invalid VLAN configurationExplanation Invalid VLAN configuration
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_SECURITY_VIOLATION_ANOTHER_PORT: Host [chars] bound to Port [chars] in Vlan [dec] is trying to access Port [chars] in Vlan [dec]Explanation Moved the port to violation state due to a mac address seen on one port being seen on another
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_SECURITY_VIOLATION_MAX_MAC_VLAN: Port [chars] moved to [chars] state as host [chars] is trying to access the port in vlan [dec]Explanation Moved the port to violation state due to exceeding address count
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_DISABLE: Unable to disable eth_port_sec [chars].Explanation Unable to disable eth_port_sec Service
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_UNABLE_TO_ENABLE: Unable to enable eth_port_sec [chars].Explanation Unable to enable eth_port_sec Service
Recommended Action No action is required.
Error Message ETH-PORT-SEC-3-ETH_PORT_SEC_VIOL_UPDATE_FAILED: Failed to update violation modeExplanation The transceiver for the interface specified has not been qualified on this platform for this software release
Recommended Action Replace the module with a supported transceiver. Contact Cisco TAC to get platform transceiver qualification details
Explanation Interface is down with a possible reason.
Recommended Action Collect more information about port using command showportinternalinfo/event-history'todeterminewhyitwentdown'
Explanation Age time expired for host
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_DISABLED: eth_port_sec Disabled on if_index:[hex]Explanation Eth_port_sec Service Disabled
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_DYNAMIC_MAC_ADDRESS_CLEARED: Dynamic MAC addresses for port [chars] clearedExplanation Dynamic MAC address for port cleared
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_ENABLED: eth_port_sec Enabled on if_index:[hex]Explanation Eth_port_sec Service Enabled
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_ADDITION: A new Host [chars] learnt on Port [chars] in Vlan [dec]Explanation A new host is learnt on a port
Recommended Action No action is required.
Error Message ETH-PORT-SEC-5-ETH_PORT_SEC_HOST_DELETION: Host [chars] bound to secure port [chars] in Vlan [dec] has been removedExplanation There was a critical failure in the component.
Recommended Action Please follow instructions on the syslog.
Error Message ETHPORT-2-IF_DOWN_ERROR_DISABLED: Interface [chars] is down (Error disabled. Reason:[chars])Explanation The interface encountered an error while configuring it
Recommended Action Collect more information about failed interface using command 'show port internal all interface [char]'. In most cases, you can recover using a 'shutdown' followed a 'no shutdown' on the interface or removing and re-inserting the fibre optic cable.
Error Message ETHPORT-2-IF_ERROR_SHUT_LAN_NO_DCX: Shutting lan on interface [chars] that doesn't connect to a DCBX capable adaptor.Explanation Shutting lan on interface that doesn't connect to a DCBX capable adaptor.
Recommended Action No action is required.
Error Message ETHPORT-2-IF_SEQ_ERROR: Error ([chars]) communicating with [chars] for opcode [chars] ([chars]) Follow PM <MSG_EXPL> Some component returned system error as a response to one of the port event sequence. </MSG_EXPL> ; <MSG_ACT> None </MSG_ACT> ; <MSG_DDTS> ethport </MSG_DDTS> ; <MSG_DEF> (122 << 3) - 5 -STORM_CONTROL_ABOVE_THRESHOLD </MSG_DEF> <MSG_TEXT> Traffic in port [chars] exceeds the configured threshold [chars]Explanation Traffic on specified port is beyond the configured storm-control threshold, and the excess traffic is being dropped
Recommended Action Identify source of traffic storm
Error Message ETHPORT-2-SEQ_TIMEOUT: Component [chars] timed out on response to opcode [chars] ([chars])Explanation Some component did not respond to a request in stipulated time.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETHPORT-2-SYSLOG_ETHPM_CRITICAL: Critical failure: [chars]Explanation This interface belongs to a PortChannel and the PortChannel is error disabled
Recommended Action Perform 'shut' and 'no shutdown' on the PortChannel interface that it belongs to
Error Message ETHPORT-3-IF_ERROR_VLANS_REMOVED: VLANs [chars] on Interface [chars] are removed from suspended state.Explanation The VLANs on an interface are being removed from the suspended state
Recommended Action No action is required.
Error Message ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs [chars] on Interface [chars] are being suspended. (Reason: [chars])Explanation The VLANs on an interface are being suspended due to some protocol action
Recommended Action No action is required.
Error Message ETHPORT-3-IF_NON_CISCO_TRANSCEIVER: Non-Cisco transceiver on interface [chars] is detectedExplanation The transceiver for the interface specified in the error message is not a Cisco module
Recommended Action Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced
Error Message ETHPORT-3-IF_SFP_ALARM: Interface [chars], [chars]Explanation There was an alarm on the transceiver module
Recommended Action Please do show interface transceiver details to obtain more information
Error Message ETHPORT-3-IF_SFP_ERROR: Interface [chars], [chars]Explanation There was an error on the transceiver module
Recommended Action Please do show interface transceiver details to obtain more information
Error Message ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER_VENDOR: Transceiver vendor ([hex] [hex] [hex]) for interface [chars] is not supportedExplanation The transceiver vendor for the interface specified in the error message is not supported
Recommended Action Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced
Error Message ETHPORT-3-IF_UNSUPPORTED_TRANSCEIVER: Transceiver on interface [chars] is not supportedExplanation The transceiver for the interface specified in the error message is not a Cisco supported module
Recommended Action Replace the module with a compatible transceiver. If the transceiver was purchased from Cisco, please contact Cisco TAC to get the transceiver replaced
Error Message ETHPORT-3-IF_XCVR_ALARM: Interface [chars], [chars]Explanation There was an alarm on the transceiver module
Recommended Action Please do show interface transceiver details to obtain more information
Error Message ETHPORT-3-IF_XCVR_ERROR: Interface [chars], [chars]Explanation There was an error on the transceiver module
Recommended Action Please do show interface transceiver details to obtain more information
Explanation There was an warning on the transceiver module
Recommended Action Please do show interface transceiver details to obtain more information
Error Message ETHPORT-4-IF_XCVR_WARNING: Interface [chars], [chars]Explanation There was an warning on the transceiver module
Recommended Action Please do show interface transceiver details to obtain more information
Explanation Interface is admin up
Recommended Action No action is required.
Error Message ETHPORT-5-IF_BANDWIDTH_CHANGE: Interface [chars],bandwidth changed to [chars] KbitExplanation Bandwidth of the interface has changed and this change is updated
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DCE_MODE: Interface [chars], dce mode changed to [chars]Explanation The dce mode on the port has changed
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_ADMIN_DOWN: Interface [chars] is down (Administratively down)Explanation Interface has been configured to be administratively down
Recommended Action Perform 'no shutdown'
Error Message ETHPORT-5-IF_DOWN_CFG_CHANGE: Interface [chars] is down(Config change)Explanation FCIP interface temporarily down due to reconfiguration
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_CHANNEL_ADMIN_DOWN: Interface [chars] is down (Channel admin down)Explanation This interface belongs to a PortChannel and the PortChannel is configured to be administratively down
Recommended Action Perform 'no shutdown' on the PortChannel interface that it belongs to
Error Message ETHPORT-5-IF_DOWN_CHANNEL_MEMBERSHIP_UPDATE_IN_PROGRESS: Interface [chars] is down (Channel membership update in progress)Explanation The interface belongs to a PortChannel and a configuration is being attempted on the interface while there is a configuration in progress on the PortChannel
Recommended Action Retry the configuration again
Error Message ETHPORT-5-IF_DOWN_DOMAIN_ADDR_ASSIGN_FAILURE_ISOLATION: Interface [chars] is down (Isolation due to domain id assignment failure)Explanation Isolated due to a failure while assigning a domain
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_INVALID_RCF_RECEIVED: Interface [chars] is down (Isolation due to invalid fabric reconfiguration)Explanation Invalid RCF received
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_MANAGER_DISABLED: Interface [chars] is down (Isolation due to domain manager disabled)Explanation Isolated due to domain manager being disabled
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_MAX_RETRANSMISSION_FAILURE: Interface [chars] is down (Isolation due to domain manager other side not responding)Explanation Remote end domain manager not responding
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_OTHER_SIDE_EPORT_ISOLATED: Interface [chars] is down (Isolation due to domain other side eport isolated)Explanation Isolating this interface due to the remote end being isolated
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_DOMAIN_OVERLAP_ISOLATION: Interface [chars] is down (Isolation due to domain overlap)Explanation Isolated due to domain overlap
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_ELP_FAILURE_ISOLATION: Interface [chars] is down (Isolation due to ELP failure)Explanation ELP failed on the interface
Recommended Action Check the output of 'show port internal info' in the 'ELP failure reason' field
Error Message ETHPORT-5-IF_DOWN_EPP_FAILURE: Interface [chars] is down (Error Disabled - EPP Failure)Explanation Trunk protocol failed
Recommended Action 'show port internal event-history msgs' will indicate the trunk protocol exchanges to determine why it failed
Error Message ETHPORT-5-IF_DOWN_ESC_FAILURE_ISOLATION: Interface [chars] is down (Isolation due to ESC failure)Explanation ESC failed on the interface
Recommended Action Check the output of 'show port internal event-history' to determine the ESC protocol exchanges to determine how it failed
Error Message ETHPORT-5-IF_DOWN_ETH_IF_DOWN: Interface [chars] is down(Tunnel port src interface down)Explanation Ethernet link to which the FCIP interface is bound is down
Recommended Action Ensure that the ethernet cable is connected, the interface is administratively enabled
Error Message ETHPORT-5-IF_DOWN_ETH_LINK_DOWN: Interface [chars] is down(Tunnel port src interface link down)Explanation Ethernet link to which the FCIP interface is bound is down
Recommended Action Ensure that the ethernet cable is connected and the remote end is also active
Error Message ETHPORT-5-IF_DOWN_FCOT_NOT_PRESENT: Interface [chars] is down (FCOT not present)Explanation The FCOT has been removed
Recommended Action Insert an FCOT
Error Message ETHPORT-5-IF_DOWN_FCOT_VENDOR_NOT_SUPPORTED: Interface [chars] is down (Error disabled - Fcot vendor not supported)Explanation Fcot inserted is not a supported one
Recommended Action Please contact customer support for a list of authorized transceiver vendors
Error Message ETHPORT-5-IF_DOWN_HW_FAILURE: Interface [chars] is down (Hardware Failure)Explanation The module's hardware has failed
Recommended Action Collect more information about failed module using command 'show module internal all module'
Error Message ETHPORT-5-IF_DOWN_INACTIVE: Interface [chars] is down (Inactive)Explanation The port VSAN has been suspended or deleted
Recommended Action Assign a new active port VSAN to the interface
Error Message ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_MODE: Interface [chars] is down (Error disabled - Incompatible admin port mode)Explanation The configured mode is not supported on this interface
Recommended Action Perform a 'show port internal info' to determine the list of modes supported on this interface
Error Message ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBBCREDIT: Interface [chars] is down (Error disabled - Incompatible admin port rxbbcredit)Explanation The configured receive B2B credit size is not supported
Recommended Action Get the allowed receive B2B credit size from 'show port internal info'
Error Message ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_RXBUFSIZE: Interface [chars] is down (Error disabled - Incompatible admin port rxbufsize)Explanation The configured receive buffer size is not supported
Recommended Action Get the allowed receive buffer size from 'show port internal info'
Error Message ETHPORT-5-IF_DOWN_INCOMPATIBLE_ADMIN_SPEED: Interface [chars] is down (Error disabled - Incompatible admin port speed)Explanation The configured speed is not supported on this interface
Recommended Action Perform a 'show port internal info' to determine the range of speed supported on this interface
Error Message ETHPORT-5-IF_DOWN_INITIALIZING: Interface [chars] is down (Initializing)Explanation The interface is in the process of coming up
Recommended Action If the interface is stuck in this state for a while, check the output of 'show port internal event-history' to determine what it is waiting for
Error Message ETHPORT-5-IF_DOWN_INTERFACE_REMOVED: Interface [chars] is down (Interface removed)Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_L3_NOT_READY: Interface [chars] is down (L3 not ready)Explanation System is not L3 ready: L3 license not found or router card not present
Recommended Action Please check L3 license or router card
Error Message ETHPORT-5-IF_DOWN_LINK_FAILURE: Interface [chars] is down (Link failure)Explanation The physical link has gone down
Recommended Action Ensure that the cable is connected and the remote end is not shut down
Error Message ETHPORT-5-IF_DOWN_LOOPBACK_DIAG_FAILURE: Interface [chars] is down (Diag failure)Explanation Diag failed on the interface
Recommended Action Collect more information about failed interface using command 'attach module' to connect to module
Error Message ETHPORT-5-IF_DOWN_LOOPBACK_ISOLATION: Interface [chars] is down (Isolation due to port loopback to same switch)Explanation The interface is looped back to another interface on the same switch
Recommended Action Check the connectivity of this interface and ensure that it is connected to another switch
Error Message ETHPORT-5-IF_DOWN_MODULE_REMOVED: Interface [chars] is down (module removed)Explanation Interface is down because the module was removed
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_NONE: Interface [chars] is down (None)Explanation There is no apparent reason the interface is down
Recommended Action Collect more information about port using command 'show port internal info/event-history' to determine why it went down
Error Message ETHPORT-5-IF_DOWN_NON_PARTICIPATING: Interface [chars] is down (Non participating)Explanation The loop port has been put into non participating mode
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_OFFLINE: Interface [chars] is down (Offline)Explanation The interface has been placed into the offline state
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_PARENT_ADMIN_DOWN: Interface [chars] is down (Parent interface down)Explanation Parent interface is down
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_PEER_CLOSE: Interface [chars] is down(TCP conn. closed by peer)Explanation The FCIP peer connected to this interface closed the TCP connection
Recommended Action This command will provide the peer IP address of this FCIP interface: show interface. Check to see why the peer closed the TCP connection
Error Message ETHPORT-5-IF_DOWN_PEER_RESET: Interface [chars] is down(TCP conn. reset by peer)Explanation TCP connection to the FCIP peer got reset
Recommended Action The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Check to see why the peer reset the TCP connection
Error Message ETHPORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: Interface [chars] is down (No operational members)Explanation This is a PortChannel interface and all its members are operationally down
Recommended Action Enable at least one of the PortChannel's members
Error Message ETHPORT-5-IF_DOWN_PORT_PROFILE_NOT_FOUND: Interface [chars] is downExplanation Interface is down beacuse there is no associated profile
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_PORT_VSAN_MISMATCH_ISOLATION: Interface [chars] is down (Isolation due to port vsan mismatch)Explanation Isolated due to a mismatch in the configured port VSAN of the local and remote ends
Recommended Action Configure the port VSAN of the local and remote interfaces to be the same and perform a 'shutdown' and a 'no shutdown'
Error Message ETHPORT-5-IF_DOWN_RCF_IN_PROGRESS: Interface [chars] is down (RCF in progress)Explanation There is an RCF in progress
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_SOFTWARE_FAILURE: Interface [chars] is down (Port software failure)Explanation The software servicing the data path on the port has failed
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_SRC_MOD_NOT_ONLINE: Interface [chars] is down(Tunnel source module not online)Explanation Module that has the tunnel source port of this FCIP interface is not fully online
Recommended Action The module that has the tunnel src port is coming online. Please use show mod to find module status
Error Message ETHPORT-5-IF_DOWN_SRC_PORT_NOT_BOUND: Interface [chars] is down (Tunnel port src interface unbound)Explanation Tunnel port source interface unbound
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_SRC_PORT_REMOVED: Interface [chars] is down(Tunnel src port removed)Explanation Tunnel source port of this FCIP interface has been removed
Recommended Action The src interface with ip address that matches the ip address of the bound entity is removed. This happens normally due to the module on which the src interface exists is removed
Error Message ETHPORT-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is down (Suspended due to incompatible mode)Explanation This interface belongs to a PortChannel and operational mode of the interface is different from that of the PortChannel
Recommended Action Change the mode and the trunking mode of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel
Error Message ETHPORT-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is down (Suspended due to incompatible speed)Explanation This interface belongs to a PortChannel and operational speedode of the interface is different from that of the PortChannel
Recommended Action Change the speed of the PortChannel from 'auto' and check to ensure that the remote end of the interface also belongs to the same PortChannel
Error Message ETHPORT-5-IF_DOWN_SUSPENDED_BY_WWN: Interface [chars] is down (Suspended due to incompatible remote switch WWN)Explanation This interface belongs to a PortChannel and remote switch WWN of the interface is different from that of the PortChannel
Recommended Action Ensure that this interface is connected to the same remote switch as all the other interfaces in the PortChannel
Error Message ETHPORT-5-IF_DOWN_SUSPENDED: Interface [chars] is down (Suspended)Explanation This interface belongs to a PortChannel and has been suspended due to an error while bringing it up
Recommended Action Perform a 'shutdown' and a 'no shutdown'. If this happens again obtain output of 'show port internal info/event-history' on the interface
Error Message ETHPORT-5-IF_DOWN_TCP_KEEP_ALIVE_EXPIRED: Interface [chars] is down(TCP conn. closed - Keep alive expired)Explanation TCP session to the FCIP peer got closed due to loss of TCP keep alive
Recommended Action This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr
Error Message ETHPORT-5-IF_DOWN_TCP_MAX_RETRANSMIT: Interface [chars] is down(TCP conn. closed - retransmit failure)Explanation Interface is down due to maximum retransmission failure
Recommended Action This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr
Error Message ETHPORT-5-IF_DOWN_TCP_PERSIST_TIMER_EXPIRED: Interface [chars] is down(TCP conn. closed - Persist timer expired)Explanation TCP session to the FCIP peer closed because TCP persist timer expired
Recommended Action This may be due to loss of IP connectivity. The following commands will provide the IP address of the peer and the route used connect to this FCIP peer: show interface, show ip route. Please do a trace route to check the connectivity to the peer using command:traceroute ipaddr
Error Message ETHPORT-5-IF_DOWN_UPGRADE_IN_PROGRESS: Interface [chars] is down (Linecard upgrade in progress)Explanation Upgrade of the linecard software is in progress
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_VRF_UNUSABLE: Interface [chars] is down (Vrf down)Explanation The vrf for which this interface is a member is removed
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_VSAN_MISMATCH_ISOLATION: Interface [chars] is down (Isolation due to vsan mismatch)Explanation This is a trunking interface and the VSANs configured do not match with the VSANs configured on the remote end
Recommended Action Check the VSANs configured on the local end with the remote end
Error Message ETHPORT-5-IF_DOWN_ZONE_MERGE_FAILURE_ISOLATION: Interface [chars] is down (Isolation due to zone merge failure)Explanation Isolated due to a failure during zone merge
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DOWN_ZONE_REMOTE_NO_RESP_ISOLATION: Interface [chars] is down (Isolation due to remote zone server not responding)Explanation Isolated due to remote zone server not responding
Recommended Action No action is required.
Error Message ETHPORT-5-IF_DUPLEX: Interface [chars], operational duplex mode changed to [chars]Explanation Operational duplex mode has changed when link came up
Recommended Action No action is required.
Error Message ETHPORT-5-IF_HARDWARE: Interface [chars], hardware type changed to [chars]Explanation There was a change in the hardware characteristic of an interface, such as a transceiver module plugged in or removed
Recommended Action No action is required.
Error Message ETHPORT-5-IF_RX_FLOW_CONTROL: Interface [chars], operational Receive Flow Control state changed to [chars]Explanation Operational receive flow control has changed when link came up
Recommended Action No action is required.
Error Message ETHPORT-5-IF_TRUNK_DOWN: Interface [chars], vlan [chars] downExplanation Interface [chars] is trunking, VLANs [chars] are down
Recommended Action The following commands will help determine why this VSAN is down on this interface: show interface, show port internal info interface VSAN, show port internal event-history interface vsan
Error Message ETHPORT-5-IF_TRUNK_UP: Interface [chars], vlan [chars] upExplanation Interface [chars] is trunking, VLANs [chars] are up
Recommended Action No action is required.
Error Message ETHPORT-5-IF_TX_FLOW_CONTROL: Interface [chars], operational Transmit Flow Control state changed to [chars]Explanation Operational transmit flow control has changed when link came up
Recommended Action No action is required.
Error Message ETHPORT-5-IF_UP: Interface [chars] is up [chars]Explanation Interface is up in mode specified, if applicable
Recommended Action No action is required.
Error Message ETHPORT-5-SPEED: Interface [chars], operational speed changed to [chars]Explanation Operational speed has changed when link came up
Recommended Action No action is required.
Error Message ETHPORT-5-STORM_CONTROL_BELOW_THRESHOLD: Traffic in port [chars] has fallen below the configured threshold [chars]Explanation Traffic on specified port has returned to within configured storm-control threshold
Explanation Module configuration failed
Recommended Action Module will be automatically reset
Error Message ETH_PORT_CHANNEL-1-MALLOC_FAILED: cannot allocate memory (size [dec])Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-1-MAP_PARAM_FAILURE: mapping parameter failed for [chars] [[chars]]Explanation Parameter mapping failed
Recommended Action Specified service is misbehaving; check its status
Error Message ETH_PORT_CHANNEL-1-MCAST_SEND_FAILURE: failed to send multicast [chars]: [chars]Explanation Failed to send a multicast message to all modules, usually because some module went down
Recommended Action Run show port-channel consistency to check consistency
Explanation A module is reset for not responding or returning error
Explanation Some component did not respond to a request in stipulated time.
Error Message ETH_PORT_CHANNEL-3-ADD_REM_MEMBERS_FAILURE: [chars]Explanation Some service(s) failed to add or remove ports to port-channel
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-ALL_DROP_TIMEOUT: Some component(s) timed out on dropping notif:[chars] (for:[chars]); Please collect <show system internal mts buffers details>Explanation Some component did not respond to a request in stipulated time.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-COMPAT_CHECK_FAILURE: [chars] is not compatibleExplanation Compatibility check failed when adding ports to port-channel
Recommended Action Make sure the compatibility parameters are consistent while adding ports to port-channel, or use force option
Error Message ETH_PORT_CHANNEL-3-GENERAL_ERROR: [chars]Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-3-LACP_ERROR: [chars] [chars]Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-3-MSG_SEND_FAILURE: failed to send [chars] to sap [dec]: [chars]Explanation Failed to send a message
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-3-NUM_ACTIVE_PORTS_ERROR: Port-channel:[chars] active_nports [dec]; No member is active; Please collect <show tech-support port-channel/ethpm>Explanation Port-channel num active ports error
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-PCM_HWCFG_FAIL_ERROR: Port-channel:[chars] mbr:[chars] SAP [dec] returned error [chars] for opc [chars]; if lacp port-channel please collect <show tech-support lacp all> or please collect <show tech-support port-channel/ethpm>Explanation Port-channel hwcfg fail error
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-PCM_INTERNAL_ERROR: Port-channel:[chars] mbr:[chars]; if lacp port-channel please collect <show tech-support lacp all> or please collect <show tech-support port-channel/ethpm>Explanation Port-channel internal error
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-PCM_PORT_DEL_IN_PC_UP_ERROR: Port-channel:[chars] mbr:[chars]; if lacp port-channel please collect <show tech-support lacp all> or please collect <show tech-support port-channel/ethpm>Explanation Port-channel port del in pc_up. Shut resp recvd before bundle member down
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-PCM_PORT_DOWN_IN_PC_UP_ERROR: Port-channel:[chars] mbr:[chars]; if lacp port-channel please collect <show tech-support lacp all> or please collect <show tech-support port-channel/ethpm>Explanation Port-channel port down in pc_up. No bundle member down
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-PORT_CHANNEL_NOT_FOUND: [chars] is not foundExplanation Cannot find port-channel in its database, which indicates an inconsistency with an external component
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-3-RSP_TIMEOUT: Component [chars] timed out on response to opcode:[chars] (for:[chars])Explanation Some component did not respond to a request in stipulated time.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message ETH_PORT_CHANNEL-3-TIMEOUT: timed out after [dec] seconds [type [chars], state [chars]]Explanation Some operation timed out
Recommended Action Run show port-channel consistency to check all module connectivity and consistency
Explanation Port is removed from a port-channel because a different module was inserted to the same slot
Recommended Action You lost some ports from port-channel, check if you want to add ports in the new module to the same port-channel.
Error Message ETH_PORT_CHANNEL-4-PORT_INDIVIDUAL: port [chars] is operationally individualExplanation The port is operating as an individual link even though it is locally or remotely configured to be part of a port channel
Recommended Action Check the configuration of the port locally and remotely to ensure that it can operate as part of a port channel
Error Message ETH_PORT_CHANNEL-4-PORT_NOT_FOUND: port [chars] is not part of port-channelExplanation Cannot find the port in port-channel database, which indicates an inconsistency with an external component
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-4-RACE_WARN: [chars]Explanation Warning of possible race condition
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-4-UNEXPECTED_RESPONSE: unexpected response [chars] from [chars]Explanation Auto create process on the port failed
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-CREATED: [chars] createdExplanation A port-channel is created
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-DELETED: [chars] deletedExplanation A port-channel is deleted
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-FOP_CHANGED: [chars]: first operational port changed from [chars] to [chars]Explanation The first operational port in a port-channel is changed
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_MODE: Interface [chars] is down (Suspended due to incompatible modeExplanation Compatibility check failed when adding ports to port-channel
Recommended Action Make sure the compatibility parameters are consistent between the ports and the port-channel
Error Message ETH_PORT_CHANNEL-5-IF_DOWN_SUSPENDED_BY_SPEED: Interface [chars] is down (Suspended due to incompatible speedExplanation Operational compatibility check failed on the port in a port-channel
Recommended Action Make sure the compatibility parameters are consistent between the ports and the port-channel
Error Message ETH_PORT_CHANNEL-5-MAX_CHANNEL_DISALLOWED: Module failed to come online because port channel interface <port-channel number> greater than [dec] is presentExplanation The port-channel number configured on the switch is larger than 128
Recommended Action Delete the set of port channel interface <port-channel interface> which is greater than 128
Error Message ETH_PORT_CHANNEL-5-OPINPROGRESS_TIMEOUT: [chars] operation in progress has timed outExplanation Port-channel operation in progress has timed out
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PCM_CHANNEL_GRP_ID_DEPRECATED: channel-group <idRecommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PCM_MEMBERSHIP_CHANGE_ADD: Interface [chars] is added to [chars]Explanation Membership change event occured on the port-channel interface.
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PCM_MEMBERSHIP_CHANGE_DEL: Interface [chars] is removed from [chars]Explanation Membership change event occured on the port-channel interface.
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PCM_ROLLBACK_MAX_PORTS_EXCEEDED: Max ports per channel exceeded while trying to create port-channel [dec]. Rollback will be performed.Explanation No action is required.
Recommended Action Port-channel
Error Message ETH_PORT_CHANNEL-5-PCM_ROLLBACK: Rollback for Port Channel [dec], module [dec]Explanation Channel creation failed. Rollback has been performed.
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_ADDED: [chars] added to [chars]Explanation Ports are added to a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_DOWN: [chars]: [chars] is downExplanation Port goes down in a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_HOT_STANDBY_DOWN: [chars]: hot-standby port [chars] is downExplanation Port-channel hot-standby member goes down
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_HOT_STANDBY: [chars]: [chars] goes to hot-standbyExplanation Port goes to hot-standby in a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_INDIVIDUAL_DOWN: individual port [chars] is downExplanation Port-channel member operating in individual mode goes down
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_REMOVED: [chars] removed from [chars]Explanation Ports are removed from a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_SUSPENDED: [chars]: [chars] is suspendedExplanation Port is suspended in a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-PORT_UP: [chars]: [chars] is upExplanation Port comes up in a port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-SUBGROUP_ID_PORT_ADDED: Interface [chars] is added to port-channel[dec] with subgroup id [dec]Explanation The port is added to port-channel
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-5-SUBGROUP_ID_PORT_REMOVED: Interface [chars] is removed from port-channel[dec] with subgroup id [dec]Explanation Resync modules with sup after an error or switchover
Explanation Port-channel manager finished global synchronization
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-7-GSYNC_REQ: requesting global synchronizationExplanation Port-channel manager requested a global synchronization from active sup
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-7-START_ACTIVE: started in active modeExplanation Port-channel manager started in active mode
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-7-START_DEFAULT: started with default configurationExplanation Port-channel manager started with default configuration
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-7-START_STANDBY: started in standby modeExplanation Port-channel manager started in standby mode
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-7-START_STATEFUL: started statefullyExplanation Port-channel manager started with running configuration
Recommended Action No action is required.
Error Message ETH_PORT_CHANNEL-7-START_STATELESS: started statelesslyExplanation Port-channel manager started with startup configuration
Explanation Internal IPC operation failed in Event Manager Client
Explanation Configuring Policy Action for Monitor Collect Policy isnot allowed and hence, has been rejected
Explanation Event Manager could not initialize local policy store
Recommended Action No action is required.
Error Message EVMC-5-MALLOC_FAILURE: [chars]([dec]): Memory allocation failureExplanation Event Manager Client process could not allocate memory
Recommended Action No action is required.
Error Message EVMC-5-RT_PSS_OP_FAILURE: [chars]([dec]): Failed to [chars]. Error:[chars]Explanation Delete from PSS failed
Recommended Action No action is required.
Error Message EVMS-2-EVMS_PSS_WRITE_FAILURE: Write to PSS failedExplanation Write to PSS failed
Recommended Action No action is required.
Error Message EVMS-2-EVMS_SHOW_POLICY_ALLOC_FAILURE: Insufficient memory: policy information shown will be incompleteExplanation Memory allocation failed. so complete requested information is not being shown
Explanation The default system policy actions are being skipped
Explanation FCMPLS tunnel process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message FC-TUNNEL-3-IPFC_ERROR: IPFC API, [chars], failed with error [hex]Explanation FCMPLS tunnel invoked IPFC API and received the error code. [chars] describes the API and 0x[hex] specifies the error
Recommended Action No action is required.
Error Message FC-TUNNEL-3-MTS_ERROR: MTS message transmission failed with error [dec]Explanation FCMPLS tunnel process unsuccessfully tried to send a MTS message. MTS errro number is specified in [dec]
Recommended Action No action is required.
Error Message FC-TUNNEL-3-NS_ERROR: FCNS API, [chars], failed with error [hex]Explanation FCMPLS tunnel invoked FCNS API and received the error code. [chars] describes the API and 0x[hex] specifies the error
Recommended Action No action is required.
Error Message FC-TUNNEL-3-PM_ERROR: Port Manager API, [chars], failed with error [hex]Explanation FCMPLS tunnel invoked Port Manager API and received the error code. [chars] describes the API and 0x[hex] specifies the error
Recommended Action No action is required.
Error Message FC-TUNNEL-3-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] failed with error [hex]Explanation FCMPLS tunnel read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system error code
Recommended Action No action is required.
Error Message FC-TUNNEL-3-PSS_ERROR: PSS operation [chars] returned error: [hex]Explanation [chars] specifies the context where the failure occurred and 0x[hex] specifies the error
Recommended Action No action is required.
Error Message FC-TUNNEL-3-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for [chars] failed with error [hex]Explanation FCMPLS tunnel read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system error code
Recommended Action No action is required.
Error Message FC-TUNNEL-3-RIB_ERROR: RIB API, [chars], failed with error [hex]Explanation FCMPLS tunnel invoked RIB API and received the error code. [chars] describes the API and 0x[hex] specifies the error
Recommended Action No action is required.
Error Message FC-TUNNEL-3-RSVP_PROTO_ERROR: RSVP protocol error: [chars]Explanation RSVP-TE protocol error is encountered. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message FC-TUNNEL-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is receivedExplanation FCMPLS tunnel process received unexpected MTS event. MTS opcode is specified in [dec]
Explanation The logical fc tunnel interface is down. This may be due to a reconfiguration on the fc tunnel, or issues on the underlying physical interface
Recommended Action If this is not due to a known reconfiguration, you should verify connectivity at the physical port level, and then on then on the fc tunnel interface. Furthermore, verify the physical ports along the fc tunnel path operate in the TE mode
Error Message FC-TUNNEL-5-MSG_INTERFACE_UP: Interface [chars] is upExplanation FCC_LC has error sending heart beat
Recommended Action No action is required.
Error Message FCC_LC-2-EXITING: Exiting fcc_lc: [chars]Recommended Action No action is required.
Error Message FCC_LC-2-HEART_BEAT_NOT_SENT: Heart beat not sent for [dec] millisecsExplanation FCC_LC has not sent heart beat
Recommended Action No action is required.
Error Message FCC_LC-2-SHUTDOWN: Process shutting down: [chars]Explanation FCC_LC Process is shutting down
Recommended Action No action is required.
Error Message FCC_LC-2-UNABLE_READ_DATA: Unable to read fcc data ([chars])Explanation FCC is unable to read and process relevant FCC data
Explanation FCC_LC has received a malformed/unrecognized message
Recommended Action No action is required.
Error Message FCC_LC-5-DISABLE: FCC_LC has been disabledExplanation FCC_LC has been disabled
Recommended Action No action is required.
Error Message FCC_LC-5-ENABLE: FCC_LC has been enabledExplanation FCC_LC has been enabled
Recommended Action No action is required.
Error Message FCC_LC-5-STARTING: FCC_LC process startedExplanation FCC_LC is active for packets with priority <= [threshold]
Explanation FCC has received a malformed/unrecognized message
Recommended Action No action is required.
Error Message FCC-5-CONGESTION_STATE_CHANGE_NOTIF: Received Congestion State Change notification to state: [dec]Explanation FCC has received a Contestion State Change Notification
Recommended Action No action is required.
Error Message FCC-5-DISABLE: FCC has been disabledExplanation FCC has been disabled
Recommended Action No action is required.
Error Message FCC-5-ENABLE: FCC has been enabledExplanation FCC has been enabled
Recommended Action No action is required.
Error Message FCC-5-RATE_LIMIT_END_NOTIF: Received Rate Limit End notificationExplanation FCC has received a Rate Limit End Notification
Recommended Action No action is required.
Error Message FCC-5-RATE_LIMIT_START_NOTIF: Received Rate Limit Start notificationExplanation FCC has received a Rate Limit Start Notification
Recommended Action No action is required.
Error Message FCC-5-STARTING: FCC process startedExplanation FCC is active for packets with priority <= [threshold]
Explanation Serious errors which affect all normal operations occurred
Explanation Unexpected errors which affect some normal operations occurred
Recommended Action No action is required.
Error Message FCDDH-SLOT#-5-LOG_FCDDH_NOTICE: [chars]Explanation Serious errors which affect all normal operations occurred
Explanation Illegal event received in Global Configuration FSM
Recommended Action No action is required.
Error Message FCDD-SLOT#-5-LOG_FCDD_NOTICE: [chars]Explanation Major configuration changes
Recommended Action No action is required.
Error Message FCDD-SLOT#-5-LOG_FCDD_RESCAN_FSM: [chars]Explanation Illegal event received in Rescan FSM
Recommended Action No action is required.
Error Message FCDD-SLOT#-5-LOG_FCDD_TZONE_FSM: [chars]Explanation Illegal event received in Twilight Zone Remover FSM
Recommended Action No action is required.
Error Message FCDD-SLOT#-5-LOG_FCDD_VCONF_FSM: [chars]Explanation Illegal event received in VSAN Configuration FSM
Recommended Action No action is required.
Error Message FCDD-SLOT#-5-LOG_FCDD_VNO_FSM: [chars]Explanation Illegal event received in VSAN Normal Operation FSM
Explanation Unexpected errors which affect some normal operations occurred
Explanation Conflict detected ([dec]) domain ID [dec] with WWN [chars].
Recommended Action Check which switches have the same WWN and change either one; then change either's domain ID.
Error Message FCDOMAIN-2-EPORT_ISOLATED: Isolation of interface [chars] (reason: [chars])Explanation Fcdomain has isolated interface [chars] (reason: [chars].) Perform a show interface. Based on the reason specified, you might have to ensure domains are adequate and unique in the VSAN and perform a disruptive restart [fcdomain restart disruptive vsan <vsan-id>] or to reinitialize the port.
Recommended Action No action is required.
Error Message FCDOMAIN-2-FC2BIND_FAILED: Bind to FC2 Service failedExplanation Fcdomain has not been able to contact the FC2 module.
Recommended Action No action is required.
Error Message FCDOMAIN-2-FC2_INITIALIZATION_FAILED: FC initialization sequence failedExplanation The fcdomain has not been able to complete the initialization sequence with the Fibre Channel subsystem. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.
Recommended Action No action is required.
Error Message FCDOMAIN-2-FC2_SET_SOCKOPT_DM_SOCK_FAILED: set sockopt to FC2 Service failedExplanation Fcdomain has not been able to setsockopt to the FC2 module.
Recommended Action No action is required.
Error Message FCDOMAIN-2-FCID_PERSISTENT_TBL_COMPLETELY_FULL: FCID persistent table is completely fullExplanation The FCID persistent table is full. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table. No more entries can be saved as persistent FCIDs across reboots.
Recommended Action Purge stale entries [purge fcdomain fcid] to obtain more free entries OR disable the feature on certain VSANs which are not critical enough [no fcdomain fcid persistent].
Error Message FCDOMAIN-2-HIGH_PRIORITY_MTSBIND_FAILED: Bind for high priority IPC failedExplanation Fcdomain has not been able to contact the Inter Process Communication (IPC) module for its high priority queue.
Recommended Action No action is required.
Error Message FCDOMAIN-2-INITIALIZATION_FAILED: Initialization sequence failedExplanation The fcdomain has not been able to complete the initialization sequence. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.
Recommended Action No action is required.
Error Message FCDOMAIN-2-MTSBIND_FAILED: Bind to IPC failedExplanation Fcdomain has not been able to contact the Inter Process Communication (IPC) module.
Recommended Action No action is required.
Error Message FCDOMAIN-2-MTSREGISTRATION_FAILED: Registration of opcodes with IPC Service failedExplanation Fcdomain has not been able to register its messages with the Inter Process Communication (IPC) module.
Recommended Action No action is required.
Error Message FCDOMAIN-2-MTS_INITIALIZATION_FAILED: IPC initialization sequence failedExplanation The fcdomain has not been able to complete the initialization sequence with the IPC (Inter Process Communication) subsystem. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.
Recommended Action No action is required.
Error Message FCDOMAIN-2-MY_NON_VIRTUAL_DOM_CONFLICTS: During VSAN merge detected that the local switch has the same domain ID [dec] and WWN [chars] of another switchExplanation It has been detected that the local switch has the same domain ID [dec] and WWN [chars] of another switch.
Recommended Action Check which switches have the same WWN and change either one; then change either's domain ID.
Error Message FCDOMAIN-2-NON_VIRTUAL_DOMS_CONFLICTS: During VSAN merge detected conflict between two switches having the same non-virtual domain ID [dec] and the same WWN [chars]Explanation It has been detected that two switches have the same non-virtual domain ID [dec] and the same WWN [chars].
Recommended Action Check which switches have the same WWN and change either one; then change either's domain ID.
Error Message FCDOMAIN-2-PSSBIND_FAILED: Bind to Persistent Storage Service failedExplanation Fcdomain has not been able to contact the Persistent Storage Service (PSS).
Recommended Action No action is required.
Error Message FCDOMAIN-2-RDIRJT: Rejected request for domain ID [dec], WWN requestor [chars] (reason code [dec])Explanation An invalid request for domain IDs has been rejected by fcdomain.
Recommended Action Perform [show fcdomain vsan <vsan-id>] for all the switches in the affected VSAN; if a switch does not have a valid current domain ID, configure preferred domain ID zero, then perform [fcdomain restart vsan <vsan-id>] in the affected VSAN.
Error Message FCDOMAIN-2-SYSBIND_FAILED: Bind to System Manager service failedExplanation Fcdomain has not been able to contact the System Manager.
Recommended Action No action is required.
Error Message FCDOMAIN-2-SYSMGR_INITIALIZATION_FAILED: System Manager initialization sequence failedExplanation The fcdomain has not been able to complete the initialization sequence with the System Manager. fcdomain depends on resources not available at the moment: the switch might be short in memory or some other component might be unable to provide the necessary information to fcdomain.
Explanation A remote switch attempted to locally apply an allowed domains configuration that doesn't include all currently assigned domains or the locally configured domain.
Recommended Action No action is required.
Error Message FCDOMAIN-3-COMMITERRORREMOTEINVALIDALLOWEDDOMS: A remote switch (domain ID [dec], WWN [chars]) refuses to locally apply the proposed allowed domainsExplanation The remote switch with domain ID [dec] and WWN [chars] refuses to locally apply the proposed allowed domains probably due to incompatibility with its local configured domain or the domain ID list.
Recommended Action Check the configuration on the remote switch, and make sure that the proposed allowed domains include it. Also, make sure that the the proposed allowed domains include all the domains in the domain ID list.
Error Message FCDOMAIN-3-MTSOPENTRX_FAILED: IPC failure (opening of a transaction failed)Explanation Fcdomain was not able to open a transaction( HA Purposes.)
Recommended Action No action is required.
Error Message FCDOMAIN-3-MTSRECV_FAILED: IPC failure (receiving of a message failed)Explanation Fcdomain has not been able to receive a message from the Inter Process Communication (IPC) module.
Recommended Action Please perform fcdomain restart in the affected VSAN (non disruptive.)
Error Message FCDOMAIN-3-MTSRESP_FAILED: IPC failure replying to a request message (error [hex])Explanation Fcdomain has not been able to reply to a request coming from the Inter Process Communication (IPC) module (error [hex]).
Recommended Action Please perform fcdomain restart in the affected VSAN (non disruptive).
Error Message FCDOMAIN-3-MTSSENDREQ_FAILED: IPC failure (sending of a request failed)Explanation Fcdomain was not able to send a request using the Inter Process Communication module.
Recommended Action Please perform [fcdomain restart vsan <vsan-id>] in the affected VSAN (non disruptive.)
Error Message FCDOMAIN-3-MTSSEND_FAILED: IPC failure (sending of a message (syserr [hex], opc [dec], mtsq [dec], sap.node [hex], sap_addr [dec]) failed)Explanation Fcdomain has not been able to send a message to the Message Transactional Service (MTS).
Recommended Action Please perform [fcdomain restart vsan <vsan-id>] in the affected VSAN (non disruptive).
Error Message FCDOMAIN-3-MTS_H_RECV_FAILED: IPC failure (receiving of a message failed)Explanation Fcdomain has not been able to receive a message from the Inter Process Communication (IPC) module.
Recommended Action Please perform fcdomain restart in the affected VSAN (non disruptive.)
Error Message FCDOMAIN-3-NVRAMFAILURE: NVRAM open failedExplanation Reading the last assigned runtime domain IDs from Non Volatile RAM (NVRAM) failed.
Recommended Action Fcdomain is able to continue without access to the Non Volatile RAM (NVRAM.)
Error Message FCDOMAIN-3-PORT_SUSPENDED: Response (Cmd Code [hex]) for SWILS [hex] intended for [chars] is received on [chars]Explanation An FC2 response frame (Command Code [hex]) for SWILS [hex] that was intended for interface [chars] has been received on [chars] instead.
Recommended Action Check the configuration of both interfaces on the local switch and the interfaces on the other side of their corresponding links. In particular, check whether they should all belong to the same port-channel.
Error Message FCDOMAIN-3-SDWRAPBIND_FAILED: Bind to debug server failedExplanation Fcdomain feature has not been able to contact the debug service. Any problems occurring in the fcdomain feature will not be logged.
Recommended Action No action is required.
Error Message FCDOMAIN-3-SDWRAPHISTINIT_FAILED: Initialization of history message list failed.Explanation Fcdomain feature has not been able to contact the debug history service. Any problems occurring in the fcdomain feature will not be logged to this debug history.
Recommended Action No action is required.
Error Message FCDOMAIN-3-VSAN_MERGE_DETECTED: Merge detected with VSAN [dec] (Common Fabric Name [chars])Explanation The local VSAN and VSAN [dec] have the same principal switch [chars], hence are connected in the same logical fabric.
Explanation When distribution is enabled, it is recommended to modify the allow domain list on the principal switch only.
Recommended Action Abort the current session on the local switch and start a new one on the principal switch.
Error Message FCDOMAIN-4-FABRICCONFSTARTRCF: Disruptive reconfiguration startedExplanation A disruptive reconfiguration (RCF phase) of the VSAN has started. This can happen when two or more fabrics merge disruptively, or when the user manually triggers a diruptive reconfiguration of the VSAN.
Recommended Action No action is required.
Error Message FCDOMAIN-4-FC2_CORRUPTED: Received malformed FC2 [chars] frameExplanation Fcdomain received a malformed FC2-SWILS frame.
Recommended Action No action is required.
Error Message FCDOMAIN-4-FCID_PERSISTENT_TBL_ALMOST_FULL: FCID persistent table is almost fullExplanation Fcdomain has 80% or more of the FCID persistent table full with entries. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table.
Recommended Action Purge stale entries [purge fcdomain fcid] to obtain more free entries.
Explanation All the currently existing VSANs have the domain ID type configured as preferred. This means that with a low probability the domain ID of the local VSAN might change afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a principal link flaps. A principal link is either an upstream or a downstream link.
Recommended Action Type [fcdomain domain <dom-id> static vsan <vsan-id>] to configure as static the domain ID type in an existing VSAN.
Error Message FCDOMAIN-5-FCIDP_DISABLED: FCID persistency feature is currently not enabled in any of the existing VSANsExplanation All the currently existing VSANs have the FCID persistency feature disabled.
Recommended Action Type [fcdomain fcid persistent vsan <vsan-id>] to enable FCID persistency in an existing VSAN. Type [fcdomain fcid persistent global-enable] to automatically enable the FCID persistency feature on all newly created VSANs.
Error Message FCDOMAIN-5-FCID_PERSISTENT_TBL_HALF_FULL: FCID persistent table is half fullExplanation Fcdomain has 50% of the FCID persistent table full with entries. Perform [show fcdomain fcid persistent vsan <vsan-id>] to view the entries currently in the table.
Recommended Action You may want to purge stale entries [purge fcdomain fcid] to obtain more free entries.
Error Message FCDOMAIN-5-UNKNOWNDOMAININCFSDATAREQUEST: Received CFS Data request from unknown domain [dec].Explanation A CFS Data request from the unknown domain [dec] has been received.
Recommended Action No action is required.
Error Message FCDOMAIN-5-UNKNOWNDOMAININCFSLOCKREQUEST: Received CFS Lock request from unknown domain [dec].Explanation A CFS Lock request from the unknown domain [dec] has been received.
Recommended Action No action is required.
Error Message FCDOMAIN-5-UNKNOWNDOMAININCFSRELEASEREQUEST: Received CFS Release request from unknown domain [dec].Explanation A CFS Release request from the unknown domain [dec] has been received.
Recommended Action No action is required.
Error Message FCDOMAIN-5-UNKNOWNDOMAININUNKNOWNCFSREQUEST: Received CFS request from unknown domain [dec].Explanation A CFS request from the unknown domain [dec] has been received.
Explanation Build Fabric has been started in this VSAN
Recommended Action No action is required.
Error Message FCDOMAIN-6-CANNOTFREESINGLEFCID: Impossible to free single FCIDsExplanation Impossible to free single FCIDs.
Recommended Action No action is required.
Error Message FCDOMAIN-6-CLEARLOCKNOTIFICATIONRECEIVED: Implict lock release.Explanation Lock has been implicitly released due to a clear session operation.
Recommended Action No action is required.
Error Message FCDOMAIN-6-DEVICEALREADYOWNSDIFFERENTFCIDS: The device already owns different FCIDsExplanation Requested different FCIDs without any freeing in between.
Recommended Action No action is required.
Error Message FCDOMAIN-6-DOMAINID_INVALID: Local domain ID invalidExplanation The local domain ID is invalid.
Recommended Action No action is required.
Error Message FCDOMAIN-6-DOMAINID_VALID: Local domain ID [dec] availableExplanation The domain ID [dec] is available.
Recommended Action No action is required.
Error Message FCDOMAIN-6-DOWNSTREAM_SWITCHED: Downstream interface has been fast-switched from [chars] to [chars]Explanation Because of a link failure the downstream interface has been fast-switched from [dec] to [dec].
Recommended Action No action is required.
Error Message FCDOMAIN-6-EPORT_ALREADY_CREATED: Interface [chars] already createdExplanation Interface [chars] already created.
Recommended Action No action is required.
Error Message FCDOMAIN-6-EPORT_ALREADY_DOWN: Interface [chars] is already downExplanation Interface [chars] already down.
Recommended Action No action is required.
Error Message FCDOMAIN-6-EPORT_CLEANUP: Interface [chars] received cleanup requestExplanation Fcdomain on interface [chars] has received a cleanup request.
Recommended Action No action is required.
Error Message FCDOMAIN-6-EPORT_CREATED: Creation of interface [chars]Explanation Fcdomain is going to create interface [chars].
Recommended Action No action is required.
Error Message FCDOMAIN-6-EPORT_DOWN: Interface [chars] is downExplanation Fcdomain is going to remove interface [chars] from its database.
Recommended Action No action is required.
Error Message FCDOMAIN-6-FABRICCONFSTARTBF: Non disruptive reconfiguration startedExplanation A non disruptive reconfiguration (BF phase) of the VSAN has started. This can happen when two or more fabrics merge, or when the user manually triggers a non diruptive reconfiguration of the VSAN.
Recommended Action No action is required.
Error Message FCDOMAIN-6-FABRICNAME_INVALID: Fabric name not availableExplanation Fabric name not available.
Recommended Action No action is required.
Error Message FCDOMAIN-6-FABRICNAME_VALID: Fabric name [chars] availableExplanation Fabric name [chars] available.
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCIDALREADYFREE: FCIDs already freeExplanation FCIDs already free.
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCIDNOTSTORED: FCIDs not storedRecommended Action No action is required.
Error Message FCDOMAIN-6-FCIDP_ENABLED_DOM_TYPE_PREFERRED: FCID persistency is enabled, but the domain ID type is configured as preferredExplanation The FCID persistency feature is enabled, but the domain ID type is configured as preferred. This means that with a low probability the domain ID of the local VSAN might change afer a reconfiguration. A reconfiguration can happen when two or more VSANs are merged or a principal link flaps. A principal link is either an upstream or a downstream link. Should the domain ID change, all the FCIDs associated with it would be invalidated.
Recommended Action Type [fcdomain domain <dom-id> static vsan <vsan-id>] to configure as static the domain ID type in an existing VSAN.
Error Message FCDOMAIN-6-FCIDS_ASSIGNED: Assigned a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex]Explanation Assigned a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCIDS_FREED: Freed a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex]Explanation Freed a sequence of 256 contiguous FCIDs starting from FCID [hex]:[hex]:[hex].
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCID_ASSIGNED: Assigned single FCID [hex]:[hex]:[hex]Explanation Assigned single FCID [hex]:[hex]:[hex].
Recommended Action No action is required.
Error Message FCDOMAIN-6-FCID_FREED: Freed single FCID [hex]:[hex]:[hex]Explanation Freed single FCID [hex]:[hex]:[hex].
Recommended Action No action is required.
Error Message FCDOMAIN-6-INCORRECTDOMAINRANGE: Requested FCIDs with domain field not in expected rangeExplanation Requested FCIDs with domain field not in expected range.
Recommended Action No action is required.
Error Message FCDOMAIN-6-INCORRECTDOMAIN: Requested FCIDs with domain field different from local domainExplanation Requested FCIDs with domain field different from local domain.
Recommended Action No action is required.
Error Message FCDOMAIN-6-INVALIDARG: Requested FCID of type 00.00.YY, but specifying an entire areaExplanation Requested FCID of type 00.00.YY, but specifying an entire area.
Recommended Action No action is required.
Error Message FCDOMAIN-6-MY_SAME_WWN_DIFFERENT_DOMS_CONFLICTS: During VSAN merge detected local WWN [chars] is already in use by another switch (the two switches have different domain IDs: [dec] (local) and [dec])Explanation It has been detected that the local switch has the same WWN [chars] of another switch, and that they have different domain IDs: [dec] (local) and [dec].
Recommended Action Check which switches have the same WWN and change either one.
Error Message FCDOMAIN-6-NODOMAIN: Local domain not availableExplanation The local domain is not available yet.
Recommended Action No action is required.
Error Message FCDOMAIN-6-NOFREEFCID: No free FCIDsRecommended Action No action is required.
Error Message FCDOMAIN-6-NOTOWNER: Feature [dec] cannot free FCID [dec]:[dec]:[dec] (feature [dec] is the actual owner)Explanation Feature UUID [dec] cannot free FCID [dec]:[dec]:[dec] because it is not its owner (UUID actual owner is [dec]).
Recommended Action No action is required.
Error Message FCDOMAIN-6-OTHER_SIDE_VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN merge detected overlap with virtual IVR domain ID [dec] from across the linkExplanation It has been detected an overlap with the virtual IVR domain ID [dec] from across the link during an attempt to merge the local VSAN.
Recommended Action No action is required.
Error Message FCDOMAIN-6-PSWSSTARTED: Principal Switch Selection startedExplanation Fcdomain started a principal switch selection phase to elect a principal switch in this VSAN.
Recommended Action No action is required.
Error Message FCDOMAIN-6-RCF_STARTED: RCF started by [chars]Explanation Reconfigure Fabric has been started in this VSAN
Recommended Action No action is required.
Error Message FCDOMAIN-6-REQSINGLEFCIDWITHINRESERVEDRANGE: Requested single FCIDs in area [dec] within the reserved rangeExplanation Requested single FCIDs in area [dec] within the reserved range.
Recommended Action No action is required.
Error Message FCDOMAIN-6-REQUESTEDFCIDNOTFREE: Requested FCIDs not freeExplanation Requested FCIDs not free.
Recommended Action No action is required.
Error Message FCDOMAIN-6-REQUESTEDFCIDRESERVED: Requested reserved FCIDsExplanation Requested reserved FCIDs.
Recommended Action No action is required.
Error Message FCDOMAIN-6-REQUESTEDRESERVEDFCIDMISMATCH: Requested persistent FCIDs, but there is a mismatchExplanation Requested persistent FCIDs, but there is a mismatch.
Recommended Action No action is required.
Error Message FCDOMAIN-6-SAME_WWNS_DIFFERENT_DOMS_CONFLICTS: During VSAN merge detected two switches with same WWN [chars] and different non-virtual domain IDs [dec] and [dec]Explanation It has been detected that two switches have the same WWN [chars], but different non-virtual domain IDs: [dec] and [dec].
Recommended Action Check which switches have the same WWN and change either one.
Error Message FCDOMAIN-6-TIMER_UNKNOWN: fcdomain has received a notification for an unknown timer expirationExplanation A timer unknown to fcdomain has expired.
Recommended Action No action is required.
Error Message FCDOMAIN-6-UPSTREAM_SWITCHED: Upstream interface has been fast-switched from [chars] to [chars]Explanation Because of a link failure the upstream interface has been fast-switched from [dec] to [dec].
Recommended Action No action is required.
Error Message FCDOMAIN-6-UUIDNOSPACEFOUND: No available space to store the identity of the requestor the FCIDsExplanation No available space to store the identity of the requestor the FCIDs.
Recommended Action No action is required.
Error Message FCDOMAIN-6-UUIDNOTFOUND: Universal Unique ID (UUID) not foundExplanation Universal Unique ID (UUID) not found.
Recommended Action No action is required.
Error Message FCDOMAIN-6-VIRTUAL_IVR_DOMS_OVERLAPPING: During VSAN merge detected overlap with local virtual IVR domain ID [dec]Explanation It has been detected an overlap with the local virtual IVR domain ID [dec] during an attempt to merge the local VSAN.
Explanation Fcdomain was going to isolate interface [chars], but the interface is already isolated.
Recommended Action No action is required.
Error Message FCDOMAIN-7-FABRICCONFCOMPLETEDBF: Non disruptive reconfiguration completedExplanation A non disruptive reconfiguration (BF phase) completed. This can happen when two or more fabrics merged, or when the user manually triggered a non diruptive reconfiguration of the VSAN.
Recommended Action No action is required.
Error Message FCDOMAIN-7-FABRICCONFCOMPLETEDRCF: Disruptive reconfiguration completedExplanation A disruptive reconfiguration (RCF phase) of the VSAN has completed. This can happen when two or more fabrics merged disruptively, or when the user manually triggered a diruptive reconfiguration of the VSAN.
Recommended Action No action is required.
Error Message FCDOMAIN-7-FC2_RETRY: Retransmission of FC2 frame on interface [chars] (Cmd Code: [hex])Explanation Fcdomain is retrying an FC2 frame on interface [chars] due to loss/no response. The Command Code of the frame is [hex].
Recommended Action No action is required.
Error Message FCDOMAIN-7-FCID_IN_USE_PURGING_FOR_FICON_MGR: FICON needs to purge the persistent FCID table, but at least one FCID is still in use, preventing this purge from completely remove all entries belonging to the VSAN.Explanation There may be a problem in the sequence that shuts down all interfaces before fcdomain receives a request from FICON Manager to purge the persistent FCID table.
Recommended Action No action is required.
Error Message FCDOMAIN-7-FSM_FAILED: FSM transition failed on interface [chars] (current state [chars])Explanation Fcdomain state machine generated an invalid event on interface [chars], for which no proper action was defined (current state [chars].)
Recommended Action No action is required.
Error Message FCDOMAIN-7-FSM_FORBIDDEN_TRANSITION: fcdomain state machine has hit a forbidden transitionExplanation Fcdomain state machine has tried to execute a forbidden transition.
Recommended Action No action is required.
Error Message FCDOMAIN-7-INTERFACERDY: Interface [chars] readyExplanation Interface [chars] is ready.
Recommended Action No action is required.
Error Message FCDOMAIN-7-PREACTIONTYPE_UNKNOWN: fcdomain state machine has hit an unknown pre-action typeExplanation An undefined pre-action type has been used.
Recommended Action No action is required.
Error Message FCDOMAIN-7-PSWSCOMPLETED: Principal Switch Selection completedExplanation A Principal Switch Selection (PSwS phase) completed.
Recommended Action No action is required.
Error Message FCDOMAIN-7-RDIACC: Assigned domain ID [dec], WWN of requestor [chars] (requested domain ID [dec])Explanation Domain ID [dec] has been received by VSAN with WWN [chars] (requested domain ID was [dec].)
Explanation SB3 aborted exchange due to reason given. Aborts are caused by either the channel or control unit detecting a device protocol error. Recovery actions are performed to restore communication. In certain circumstances aborts occur in normal operations.
Recommended Action No action is required if communication with CUP device is still operational.
Error Message FCD-7-SB3_UCS_PER_FILE_FN: VSAN:[dec] Unit Check for perform file function, reason: [chars]Explanation SB3 failed perform file function. Failure is caused by error in the file main frame sent to director.
Recommended Action No action is required if communication with CUP device is still operational.
Explanation Fcfwd encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Name server database is full. The max number of entries, [dec], of ports is already present in the database
Recommended Action No action is required.
Error Message FCNS-2-INIT_FAILURE: : [chars]Explanation Fcns initialisation has failed due to [chars].
Recommended Action No action is required.
Error Message FCNS-2-NO_RESPONSE: for query [chars] from domain [dec]Explanation No response for query [chars] from domain [dec].
Recommended Action No action is required.
Error Message FCNS-2-PSS_VERSION_MISMATCH: : for [chars]Explanation Version mismatch for pss of type [chars].
Recommended Action No action is required.
Error Message FCNS-2-RELOAD_FAILURE: : [chars]Explanation Received a bad frame from the network: [chars].
Recommended Action No action is required.
Error Message FCNS-3-CFG_FAILURE: : [chars]Explanation A failure related to fcns configuration: [chars].
Recommended Action No action is required.
Error Message FCNS-3-CHUNK_FAILURE: : [chars]Explanation Chunk memory failure: [chars].
Recommended Action No action is required.
Error Message FCNS-3-DB_FAILURE: : [chars]Explanation A failure occured in fcns database: [chars].
Recommended Action No action is required.
Error Message FCNS-3-MALLOC_FAILURE: : [chars]Explanation Malloc failed: [chars].
Recommended Action No action is required.
Error Message FCNS-3-MTS_FAILURE: : [chars] [chars]Explanation Failure occured trying to do an MTS operation: [chars] [chars].
Recommended Action No action is required.
Error Message FCNS-3-PSS_FAILURE: : [chars]Explanation No response for query [chars] from domain [dec].
Explanation Database modification:[chars] for entry [hex].
Recommended Action No action is required.
Error Message FCNS-6-STATUS_INFO: : [chars]Explanation FCOE_MGR Line Card not licensed
Recommended Action No action is required.
Error Message FCOE_MGR-2-FCOE_MGR_PSS_RESTORE_FAILED: FCoE Manager PSS Restore operation failed, error: [chars]Explanation FCOE_MGR Service Disabled
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_ENABLED: FCOE_MGR EnabledExplanation FCOE_MGR Service Enabled
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_INFO: [chars]Explanation FCoE Manager general info
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_MODULE_LICENSE_CHECKIN: FCoE Manager License Checkin:[dec]Explanation FCOE_MGR Line Card license checked in
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_MODULE_LICENSE_CHECKOUT: FCoE Manager License Checkout:[dec]Explanation FCOE_MGR Line Card license checked out
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_SOLICITATION_FROM_SAME_MAC: FCoE Manager received Mulicast Solication from same MAC: [chars]Explanation FCoE Manager received Mulicast Solication from same MAC
Recommended Action No action is required.
Error Message FCOE_MGR-5-FCOE_MGR_VE_DUPLICATE_PEER_MAC: FCoE Manager has already received unicast advertisement from MAC [chars] on a different VE link. Bringing down this linkExplanation FCoE Manager has already received unicast advertisement from same MAC on a different VE link
Explanation The system has detected an error.
Recommended Action No action is required.
Error Message FCSP-MGR-2-FC2_E_INIT_FAILED: Fibre-Channel Initialization of an E_Port failed ( [chars])Explanation FC-SP Manager has been unable to initialize with the FC-2 E-Port infrastructure.
Recommended Action No action is required.
Error Message FCSP-MGR-2-FC2_F_INIT_FAILED: Fibre-Channel Initialization of an F_Port failed ( [chars])Explanation FC-SP Manager has been unable to initialize with the FC-2 F-Port infrastructure.
Recommended Action No action is required.
Error Message FCSP-MGR-2-FC2_UNKNOWN_FRM_RECD_CRIT: Received an unexpected/unknown FC-2 frame on [chars]Explanation The system has detected an error.
Recommended Action No action is required.
Error Message FCSP-MGR-2-FCSP_AUTHENT_FAILURE: FC-SP Authentication failure on Port [chars] (FC-SP Failure Reason: [chars] [chars])Explanation Fibre-Channel Authentication failure on Port [chars].(Reason Code [chars] Detail [chars]). Please check password configurations and ensure appropriate security modes on this port as well as peer port
Recommended Action No action is required.
Error Message FCSP-MGR-2-FCSP_ESP_MISMATCH: ESP parameters mismatch failure on Port [chars] (reason:[chars])Explanation Fibre-Channel ESP parameters mismatch with the peer on Port [chars].(Reason: [chars]). Please check ESP configurations on both side of the link and ensure appropriate ESP mode on this port as well as peer port
Recommended Action No action is required.
Error Message FCSP-MGR-2-FSMU_INIT_FAILED: State Machine Infrastructure Initialization failed ( [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message FCSP-MGR-2-IPC_INIT_FAILED: IPC (Inter Process Communication) Initialization failed ( [chars])Explanation FC-SP Manager has been unable to initialize with the IPC infrastructure.
Recommended Action No action is required.
Error Message FCSP-MGR-2-LICENSE_UNAVAILABLE: License:[chars] unavailable, service exitingExplanation License of [chars] is unavailable. Service will exit now
Recommended Action Please install the license file to continue using the feature.
Error Message FCSP-MGR-2-MEM_FAILED: Memory operations failed File: [chars] Line [dec] for size [hex] bytesExplanation The system has detected an error.
Recommended Action No action is required.
Error Message FCSP-MGR-2-POST_INIT_FAILED: Post-Initialization failed ( [chars])Explanation The system has detected an error.
Recommended Action No action is required.
Error Message FCSP-MGR-2-PSS_INIT_FAILED: PSS Infrastructure Initialization failed ( [chars])Explanation Memory allocation failed for size [dec]
Recommended Action Restart the process
Error Message FCS-2-CHUNK_ALLOC_FAILED: Chunk memory allocation failed for [chars] chunkExplanation Chunk memory allocation failed. [chars] indicates the chunk name
Recommended Action Restart the process
Error Message FCS-2-NO_RESPONSE: Retried maximum number of times for [chars] to domain [dec] in VSAN [dec]Explanation Maximum number of retires completed for [chars] form domain [dec] in VSAN [dec].
Recommended Action No action is required.
Error Message FCS-2-PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], expected version [dec].[dec].[dec]Explanation There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-2-RANDNUM_FAIL: [chars]Explanation There was a critical error during random number generation. [chars] indicates details of the error
Explanation An error occurred during an FCS database operation. [chars] indicates the reason for the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-INIT_FAIL: [chars]Explanation An error happened during FCS Initialization. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-MTS_API_ERR: [chars] : [chars]Explanation An error occurred in send or receive of an MTS message. [chars] indicates the error that occurred and [chars] indicates the error number
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-MTS_ERR: [chars]Explanation An error occurred in processing of an MTS message. [chars] indicates the error that occurred
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-NO_MTS_RESP: [chars]Explanation There was no response to an MTS request. [chars] indicates details of the MTS message
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-NO_REMOTE_RESP: No response for request [chars] from domain [dec] in VSAN [dec]Explanation There was no response to an FC2 request. [chars] indicates FCS request [dec] indicates the remote domain and [dec] the VSAN ID
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-OTHER_ERR: [chars]Explanation An FCS generic error occurred. [chars] indicates the description of the error
Recommended Action No action is required.
Error Message FCS-3-PSS_ERR: [chars]Explanation An error occurred during an FCS PSS operation. [chars] indicates the PSS operation that caused the error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FCS-3-SOCK_ERR: sd: [dec], [chars]Explanation An FC-2 Socket error occurred on socket-ID [dec]. [chars] indicates the reason for failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation An invalid FCS FC-CT frame with [chars] received from FC-ID [hex].
Explanation An API called by FCS failed. [chars] indicates the API name failed and [chars] the reason for failure
Recommended Action If this message is seen during a cold boot, it means that the queried module came up after FCS and this case can be ignored
Error Message FCS-5-DB_NOTICE: [chars]Explanation An error occurred during an FCS database operation. [chars] indicates the reason for the error
Explanation An event happend that affects FCS. [chars] indicates the event
Recommended Action No action is required.
Error Message FCS-6-REXMIT_PKT: Retransmitting request [chars] to domain [dec] in VSAN [dec]Explanation There was a retransmission of an FC2 request. [chars] indicates FCS request [dec] indicates the remote domain and [dec] the VSAN ID
Explanation Fdmi process encountered error while starting
Recommended Action No action is required.
Error Message FDMI-2-MTS_ERROR: MTS message transmission failed with error [dec]Explanation Fdmi process unsuccessfully tried to send a MTS message. MTS errro number is specified in [dec]
Recommended Action No action is required.
Error Message FDMI-2-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] failed with error [hex] for key type [dec]Explanation Fdmi read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system err code
Recommended Action No action is required.
Error Message FDMI-2-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for [chars] failed with error [hex]Explanation Fdmi read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system err code
Explanation Fdmi process received malformed frame. [chars] describes the malformation
Recommended Action No action is required.
Error Message FDMI-3-BAD_RESPONSE: response with command code: [hex]Explanation Fdmi process received bad payload in response
Recommended Action No action is required.
Error Message FDMI-3-INTERNAL_ERROR: Internal err: [chars]Explanation Fdmi process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message FDMI-3-MTS_API_ERROR: API, [chars] returned [hex]Explanation Fdmi invoked API [chars], received the error code specified in 0x[hex]
Recommended Action No action is required.
Error Message FDMI-3-MTS_FORMAT_ERROR: Unknown MTS message format in opcode [dec] from module [chars]Explanation Fdmi received message from module [chars] which contains unknown message format. MTS opcode is specified in [dec]
Recommended Action No action is required.
Error Message FDMI-3-NO_RESPONSE: No response from switch whose domain id is [dec]Explanation Fdmi process sents a inter-switch packets to switches and has not received the response
Recommended Action No action is required.
Error Message FDMI-3-PSS_ERROR: PSS operation [chars] returned err: [hex]Explanation [chars] specifies the context where the failure occured and 0x[hex] specifies the err
Recommended Action No action is required.
Error Message FDMI-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is receivedExplanation Fdmi process received unexpected MTS event. MTS opcode is specified in [dec]
Explanation Fdmi process sents a inter-switch packets to switches and has received the reject response with reason code in [chars]
Explanation AutoCheckpoint with the given name has been created successfully
Recommended Action No action is required.
Error Message FEATURE-MGR-2-FM_AUTOCKPT_IN_PROGRESS: AutoCheckpoint [chars]'s creation in progress...Explanation AutoCheckpoint creation has been requested and it should be in progress
Recommended Action No action is required.
Error Message FEATURE-MGR-2-FM_AUTOCKPT_SUCCEEDED: AutoCheckpoint [chars] created successfullyExplanation AutoCheckpoint with the given name has been created successfully
Recommended Action No action is required.
Error Message FEATURE-MGR-2-FM_FEATURE_LICENSE_ERROR: the license operation for feature failed [hex] [chars]Explanation License operation was not successful, check license validity for the feature
Recommended Action Please contact FM team
Error Message FEATURE-MGR-2-FM_FEATURE_OP_TIMEOUT_ERROR: feature [chars] operation failed on response timeout from service: [chars] with uuid ([hex])Explanation The error seen at FM and service communication
Recommended Action Please contact service owner with given uuid and FM team
Error Message FEATURE-MGR-2-MODULE_FM_DONE: feature manager completedExplanation Feature manager completed
Recommended Action No action is required.
Error Message FEATURE-MGR-2-MODULE_FM_STARTED: feature manager startedExplanation AutoCheckpoint creation has been requested and it should be in progress
Recommended Action No action is required.
Error Message FEATURE-MGR-6-FM_AUTOCKPT_SUCCEEDED: AutoCheckpoint [chars] created successfullyExplanation AutoCheckpoint with the given name has been created successfully
Recommended Action No action is required.
Error Message FEATURE-MGR-6-FM_FCOE_AUTOINSTALL_ON_NOT_ISOLA: auto-install feature-set fcoe on non-isolaExplanation Auto-install feature-set fcoe could be done on isola only
Explanation FEX did not come online after sup ISSU
Recommended Action No action is required.
Error Message FEX-2-FEX_OFFLINE: FEX [dec] has gone OFFLINEExplanation FEX has gone OFFLINE
Recommended Action No action is required.
Error Message FEX-2-FEX_ONLINE: FEX [dec] has come ONLINEExplanation FEX has come ONLINE
Recommended Action No action is required.
Error Message FEX-2-FEX_PORT_STATUS_CRIT: Uplink-ID [dec] of Fex [dec] that is connected with [chars] changed its status from [chars] to [chars]Explanation Fex [decimal-digit] changed port status
Recommended Action No action is required.
Error Message FEX-2-NOHMS_ENV_FEX_OFFLINE: [chars]Recommended Action Show inventory
Error Message FEX-2-NOHMS_ENV_FEX_ONLINE: [chars]Explanation FEX Service Disabled
Recommended Action No action is required.
Error Message FEX-5-FEX_ENABLED: FEX EnabledExplanation FEX Service Enabled
Recommended Action No action is required.
Error Message FEX-5-FEX_PORT_STATUS_NOTI: Uplink-ID [dec] of Fex [dec] that is connected with [chars] changed its status from [chars] to [chars]Explanation Fex [decimal-digit] changed port status
Recommended Action No action is required.
Error Message FEX-5-PINNING_CHANGED: Fex [dec] pinning information is changedExplanation Fex pinning information changed
Recommended Action No action is required.
Error Message FEX-5-SATMGR_DISABLE_FAILED: Disabling of feature FEX failed. Please remove FEX related configs from interfacesExplanation This port has the same port number assigned to other port in the same FICON VSAN. No more than one port with duplicate port number can be up in each FICON VSAN
Recommended Action Avoid duplicate number assignment in each FICON VSAN\n
Error Message FICON-2-E_PN_PA_NOT_IN_BOUND: [chars]Explanation Port number or port address in startup-configure is out of bound.
Recommended Action Change ficon port number assign configuration and save to startup-configure.\n
Error Message FICON-2-E_SAVE_FILE: [chars]Explanation Failed to save file. Possibly due to asymmetric pdcm matrix. Look for retval for actual reason.
Recommended Action Configure port prohibits in symmetrically.\n
Error Message FICON-2-SHUTDOWN: FICON Manager process shutting down: [chars]Explanation FICON Manager shutting down
Recommended Action This is a severe error. Provide the reason given in the message\n
Explanation Port number has fcip or port channle binding can not be removed nor changed.
Recommended Action Remove port number binding of the logical interface first.\n
Error Message FICON-3-E_ASSIGN_INVALID_PN_PARAM: [chars]Explanation Invalid port number parameters in command.
Recommended Action Check port numbers in the command.\n
Error Message FICON-3-E_ASSIGN_OVERLAP_PN_FAIL: [chars]Explanation Port number assigned to physical and logical can not overlap.
Recommended Action Check port numbers in the command.\n
Error Message FICON-3-E_ASSIGN_PN_NOT_DOWN_FAIL: [chars]Explanation Only port number assigned to a port in down state can be removed or changed.
Recommended Action Bring down the port first.\n
Error Message FICON-3-E_ASSIGN_PROHIBIT_PN_FAIL: [chars]Explanation Logical port address can not be prohibited.
Recommended Action Check port numbers in the command.\n
Error Message FICON-3-E_DUPLICATE_PN_ASSIGN_WARNING: [chars]Explanation This port has the same port number assigned to other port in the same FICON VSAN. No more than one port should have the same port number in each FICON VSAN
Recommended Action Avoid duplicate number assignment in each FICON VSAN\n
Error Message FICON-3-E_INVALID_PA_BRINGUP_FAIL: [chars]Explanation This port either has an invalid port address assigned or has no port address assigned.
Recommended Action Assign a valid ficon port number to the port.\n
Error Message FICON-3-E_PORT_PROHIBIT_BRINGUP_FAIL: [chars]Explanation This port has been prohibited. Prohibiting E or TE ports is not allowed. This port can not be configured in E mode or TE mode until the prohibit mask configuration is changed
Recommended Action Correct the prohibit mask (PDCM) for this port if you wish to bring it up as an E or TE port in a FICON VSAN\n
Error Message FICON-3-E_UNASSIGN_NO_PN_FAIL: [chars]Explanation Only port number already assigned can be removed.
Recommended Action Check port numbers in the command.\n
Error Message FICON-3-PDCM_CHANGE_REJ_E_PORT: [chars]Explanation The FICON Prohibit Dynamic Connectivity Mask(PDCM) change rejected because an E or TE port is being prohibited. Prohibiting an E or TE port in not allowed
Recommended Action Correct the prohibit mask (PDCM) for this port if you wish to bring the port up as an E or TE port in a FICON VSAN\n
Explanation The FICON Prohibit Dynamic Connectivity Mask (PDCM) for this port has changed. VSAN [dec], port address [dec] prohibit mask (PDCM) is now set to [chars]
Recommended Action No action is required.
Error Message FICON-6-PORT_SWAP: port number [dec] [dec] swappedExplanation FICON portnumbers swapped
Recommended Action No action is required.
Error Message FICON-6-VSAN_DISABLED: FICON disabled on VSAN [dec]Explanation FICON has been disabled on the given VSAN
Recommended Action No action is required.
Error Message FICON-6-VSAN_ENABLED: FICON enabled on VSAN [dec]Explanation An FDISC was rejected because the F-Port has reached the maximum allowed number of devices.
Recommended Action Check the configuration of the NPIV device connected to the port.
Error Message FLOGI-1-MSG_FLOGI_REJECT_FCID_ERROR: [VSAN [dec], Interface [chars]] FLOGI rejected - FCID allocation failed.Explanation An FLOGI was rejected because the FCID allocation failed.
Recommended Action Check the fcid-interop configuration, purge the persistency table and check the output of show flogi database details and see if any of the A area FCID allocation entries can be turned to single fcid allocation as per Configuration Guide
Error Message FLOGI-1-MSG_FLOGI_REJECT_TOO_MANY_LOGINS: [VSAN [dec], Interface [chars]] FLOGI rejected - this interface has reached the max num of NL-Ports ([dec])Explanation An FLOGI was rejected because the FL-Port has reached the maximum allowed number of devices.
Recommended Action Reduce the number of devices on the loop
Error Message FLOGI-1-MSG_NPIV_NOT_SUPPORTED_WITH_TRUNKING: [VSAN [dec], Interface [chars]] NPIV not supported - on this platform, NPIV is not supported on trunking interfacesExplanation The N_Port requested NPIV, but this platform does not support NPIV on trunking F_Ports.
Recommended Action Disable NPIV, or move the N_Port to a switch that supports NPIV on trunking F_Ports
Explanation An FLOGI was rejected because the ACLTCAM hardware resource is completely used.
Explanation This interface received an FLOGI with VF bit set from a non CISCO OUI; in this release Virtual Fabrics are not supported on interfaces connected to third-party devices
Recommended Action Set the trunk mode of this interface to off
Explanation The switch received an FLOGI from a trunking interface on a VSAN which has been suspended; the FLOGI frame has been dropped.
Recommended Action To bring up the VSAN again on the trunking port, remove it from the allowed VSAN list and add it again
Error Message FLOGI-5-MSG_IF_REINIT_ALPA_CONFLICT: [VSAN [dec], Interface [chars]] FL/TL interface [chars] re-initialized as ALPA - PWWN map conflict occurred.Explanation The FL/TL interface is re-initialized as ALPA used by device conflicts with an existing FLOGI session after the Loop Initialization Protocol (LIP). All the devices will re-login with new ALPA and PWWN mapping
Recommended Action No action is required.
Error Message FLOGI-5-MSG_PORT_LOGGED_IN: [VSAN [dec], Interface [chars]] Nx Port [chars] with FCID [chars] logged IN.Explanation Nx port logged in with the specified information.
Recommended Action No action is required.
Error Message FLOGI-5-MSG_PORT_LOGGED_OUT: [VSAN [dec], Interface [chars]] Nx Port [chars] logged OUT.Explanation Nx port logged out. The following commands will help determine why this Nx port logged out: 'show interface, show VSAN, show module'
Explanation Move system images from RAM to bootflash to free up some memory
Recommended Action Please remove some unnecessary files on bootflash using \delete\'CLIcommandandcopyimagesfromactivesupervisororfromremotelocation
Explanation System logflash space is almost full
Recommended Action Use 'clear core archived' or 'delete' CLI to free up space on logflash
Error Message FS-DAEMON-6-FSD_REEXPORT_NFS: Re-exported NFS mountsExplanation Exported NFS mounts are not visible in kernel and had to be reexported
Recommended Action Please use showsysteminternalflash'tomakesuretherearenoStaleNFShandles'
Explanation FABRIC_START_CFG_MGR daemon is exiting.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FSPF-2-SHUTDOWN: Routing daemon shutting down : [chars]Explanation FSPF routing daemon is shutting down because of [chars] reason.
Recommended Action This is a severe bug. Provide the reason provided and the log files for FSPF.
Explanation FSPF received a bad FC2 packet on [chars] interface, error description is [chars].
Recommended Action FSPF daemon has received a bad FC frame. Provide the output of 'debug fc2 pkt '.
Error Message FSPF-3-CHECKSUM_FAIL: Checksum test failed for LSR domain [dec]Explanation Periodic database checksum test failed for LSR for domain [dec]
Recommended Action This indicates that the internal database got corrupted because of some memory corruption bug. Provide output of 'show fspf database '. May need to power cycle the switch
Error Message FSPF-3-FC2_PROC_ERR: Error in processing [chars] packet on interface [chars], Error = [chars]Explanation An error occurred in processing a [chars] FC2 packet on [chars] interface. The internal error code is [chars].
Recommended Action Turn on 'debug fspf error' to get more information. Make sure there is no misconfiguration of FSPF parameters on the two ends of the interface. Provide output of 'show fspf vsan x' 'show fspf vsan x interface' and 'debug fspf fc pkt ' for the specific interface
Error Message FSPF-3-FLOOD_ERR: Error in flooding the local LSR, Error = [chars]Explanation FSPF had an error in flooding the local LSR, error description is [chars].
Recommended Action Provide output of 'debug fspf flood', 'debug fspf error'. If error is reported in transmitting packet check if interface is up and turn on 'debug fc2 error'
Error Message FSPF-3-HELLO_MISMATCH: Mismatch in [chars] in the Hello packet on interface [chars]Explanation There is a mismatch in the [chars] entry in the hello packet received on interface [chars]. The packet will be dropped.
Recommended Action Check the configuration of hello or dead interval on the switches on the two ends of the interface to see if there is a mismatch.
Error Message FSPF-3-INTF_TIMER_ERR: Error in processing interface timer event [chars] for interface [chars], error = [chars]Explanation FSPF had an error in processing timer event for interface chars, error is [chars].
Recommended Action Provide output of 'debug fspf error'
Error Message FSPF-3-IPC_PROC_ERR: Error in processing IPC message : Opcode = [dec], Error code = [hex]Explanation FSPF had an error in processing message of [dec] opcode, the internal error code is [dec].
Recommended Action Possibly some wrong IPC message is received by FSPF. Provide output of 'debug fspf mts pkt' and 'debug fspf error ' trace.
Error Message FSPF-3-LOCK_FAIL: FSPF failure in gaining lockExplanation There is a software failure in gaining lock of the shared resource between FSPF threads.
Recommended Action Provide output of 'debug fspf all '
Error Message FSPF-3-MTS_MSG_BEFORE_GSYNC: FSPF in standby received MTS message opcode = [hex] before GSYNCExplanation FSPF in standby received an MTS message of opcode [dec] before receiving the GSYNC message.
Recommended Action Provide output of 'debug fspf mts pkt '
Error Message FSPF-3-RIB_ERR: Error in RIB : [chars]Explanation FSPF had an error in interacting with RIB, error description is [chars].
Recommended Action Check if rib application is running using 'show processes'. Provide output of 'debug fspf route' and RIB debug traces.
Error Message FSPF-3-ROUTE_COMPUTE_ERR: Error in computing or sending routes : Error = [chars]Explanation FSPF had an error in computing routes, error description is [chars].
Recommended Action Provide the error code and output of 'debug fspf error' and 'debug fspf route' if problem is reproducible
Error Message FSPF-3-UNLOCK_FAIL: FSPF failure in releasing lockExplanation There is a software failure in releasing lock of the shared resource between FSPF threads.
Recommended Action Provide output of 'debug fspf all '
Error Message FSPF-3-VSAN_TIMER_ERR: Error in processing VSAN timer event [chars], error description = [chars]Explanation FSPF had an internal error in processing timer event, error description is [chars].
Explanation FSPF received a FC2 packet on inactive interface [chars].
Recommended Action This message may be printed for the first FSPF packet when an interface is brought up. If the message is seen continuously check if FSPF is disabled on one end for the interface or the VSAN. Otherwise check 'show interface ' output to see if interface is physically up only on one side. Also check if there is any error message printed for IPC_PROC_ERR
Error Message FSPF-4-FC2_DOWN_VSAN: Received FC2 packet on inactive vsanExplanation FSPF received a FC2 packet on inactive vsan.
Recommended Action If message seen continuously check if FSPF is disabled on the VSAN Investigate if VSAN is active and valid domain has been assigned on the switch Also check if IPC_PROC_ERR message is printed in the syslog
Error Message FSPF-4-ILLEGAL_FSM_EVENT: Illegal FSM event for state [chars] in interface [chars]Explanation An illegal protocol event has occurred for the FSPF state machine. The old state was [chars] for the interface [chars].
Recommended Action It is possible to get this message if some protocol packet gets dropped but the it should recover and move back to FULL state. Do 'show fspf interface' to check the state of the interface. If it is stuck in state other than FULL provide output of 'debug fspf event' and 'debug fspf fc pkt ' for the interfaces involved.
Error Message FSPF-4-LSR_DROPPED: [chars], Dropping LSR [dec] received on interface [chars]Explanation A LSR packet is dropped due to [chars] reason. LSR belonged to domain [dec] and was received on interface [chars].
Recommended Action Provide the reason given for dropping the LSR and output of 'debug fspf fc pkt' If the reason is checksum failure investigate possible packet corruption or truncation
Error Message FSPF-4-LSR_MIN_LS_ARRIVAL: Packet arrived before MIN_LS_ARRIVAL, Dropping LSR [dec] on interface [chars]Explanation A LSR packet is dropped as it arrived before MIN_LS_ARRIVAL. LSR belonged to domain [dec] and was received on interface [chars].
Recommended Action This can occur in transient situation and protocol recovers by retransmitting the LSR. If the message is seen continuously provide output of 'debug fspf flood ', 'debug fspf retrans' and 'debug fspf error '. The message may be seen more often when interoperating with other vendors
Error Message FSPF-4-LSU_RX_INIT: Dropping LSU received in state INIT on interface [chars]Explanation A LSU packet is dropped as interface [char] is in INIT state when it received the LSU.
Recommended Action This can occur in some transient situation. If the problem persists provide output of 'show fspf vsan x interface' and 'debug fspf fc pkt ' and 'debug fspf event vsan x'
Explanation A new LSR is added to the database for domain [dec].
Recommended Action No action is required.
Error Message FSPF-6-DELETE_LSR: LSR deleted for domain [dec]Explanation The LSR for domain [dec] is deleted from the database.
Recommended Action No action is required.
Error Message FSPF-6-INTF_OPER_DOWN: Down on interface [chars]Explanation FSPF has become operationally down on interface [chars].
Recommended Action No action is required.
Error Message FSPF-6-INTF_OPER_UP: Up on interface [chars]Explanation FSPF has become operational on interface [chars].
Recommended Action No action is required.
Error Message FSPF-6-MAX_AGE: LSR [dec] reached MaxageExplanation The LSR for domain [dec] reached the maximum age and will be deleted from all the connected switches.
Recommended Action No action is required.
Error Message FSPF-6-ROLLOVER: Rolling over the incarnation number of Local LSRExplanation The incarnation number of local LSR reached the maximum value and is rolling over.
Recommended Action No action is required.
Error Message FSPF-6-SELF_ORIGINATED: Received local LSR with higher incarnation numberExplanation A LSR for the local domain was received with incarnation number higher than the one in database. This situation should only occur initially on a topology change. If this situation persists the domain assignment of switches may not be unique
Recommended Action If this message is received continuously check if domain assignment is unique in the fabric.
Error Message FSPF-6-STATE_CREATED: Internal state created [chars]Explanation FSPF has created its internal state stateless/stateful [chars].
Recommended Action No action is required.
Error Message FSPF-6-VSAN_OPER_DOWN: Down on vsanExplanation FSPF has become operationally down on VSAN.
Recommended Action No action is required.
Error Message FSPF-6-VSAN_OPER_UP: Up with local domain [dec]Explanation Route computation thread number [dec] has been started for FSPF.
Explanation Fcfib caused a system failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Fcfib caused failures in other services
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-1-FCFIB_HW_NO_VSAN_DOM: No hardware [chars] resources for route creation to VSAN [dec] Domain [dec]Explanation Hardware does not have sufficient resources to create this route.
Recommended Action Please delete unused VSANs or assign common Domain numbers to existing VSANs.
Error Message FWM-1-FCFIB_HW_NO_VSAN: No hardware [chars] resources for route creation to VSAN [dec]Explanation Hardware does not have sufficient resources to create this route.
Recommended Action Please delete unused VSANs.
Error Message FWM-1-FCFIB_HW_PC_LIMIT: Failed to create [chars], hardware limit of [dec] would be exceededExplanation The number of hardware SAN Port Channels is limited by the platform.
Recommended Action Please configure fewer SAN Port Channels.
Error Message FWM-1-FCFIB_LICENSE_UNAVAILABLE: License: [chars] is not installed. System will not provide FC switching.Explanation Fibre Channel license is unavailable. System will not provide FC switching.
Recommended Action Please install the license file to continue using the feature.
Explanation Fcfib encountered a catastrophic error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-2-FWM_ASSERT_FAILURE: stack [[chars]]Explanation Critical assertion failed in forwarding manager
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-2-FWM_CONFIG_ERROR: Wrong configuration. Ignoring configuration.Explanation Configuration specified by the user is wrong. Configuration will be ignored.
Recommended Action No action is required.
Error Message FWM-2-FWM_IGMP_GROUP_SCALE_CONFIGURED: Number of IGMP groups configured is more than 4000, which is more than the multicast index table size. Unique fanout more than 2000 cannot be achievedExplanation Unique fanout not possible above 2000 groups
Recommended Action No action is required.
Error Message FWM-2-FWM_OIFL_MCAST_IDX_LIMIT_REACHED: [chars]Explanation The number of of multicast indices in the system have been exhausted. Cannot learn any more new multicast groups or create new vlans.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-2-FWM_PSS_RESTORE_ERROR: FwM PSS restoration has failed. Error: [chars]Explanation PSS restoration of FwM has failed during stateful restart or non disruptive upgrade.
Recommended Action No action is required.
Error Message FWM-2-FWM_VE_NOT_SUPPORTED: FCoE cannot be enabled for E mode (VE) on this platformExplanation FCoE cannot be enabled for E mode (VE) on Oregon switch with GATOS B or below.
Recommended Action No action is required.
Error Message FWM-2-FWM_VLAN_LIMIT_REACHED: [chars]Explanation Max vlan limit is reached. Cannot create a vlan. Temporary exhaustion of vlan resources.
Recommended Action No action is required.
Error Message FWM-2-STM_LEARNING_RE_ENABLE: Re enabling dynamic learning on all interfacesExplanation Re enabling learning on all interfaces after disable period expired
Recommended Action No action is required.
Error Message FWM-2-STM_LIMIT_REACHED: [chars]Explanation System station table reached its capacity - no further MAC addresses could be programmed - administration intervention may be required to avoid this problem in future
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-2-STM_LOOP_DETECT: [chars]Explanation System detected loops in the network - administration intervention may be required to avoid this problem in future
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-2-STM_MCAST_PROG_RE_ENABLE: Re enabling programming multicast entriesExplanation Re enabling programming new multicast entries because number of entries reached below threshold
Recommended Action No action is required.
Error Message FWM-2-STM_RAPID_MOVES: [chars]Explanation System detected rapid mac moves in the network - administrator intervention may be required to avoid this problem in future
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Fcfib encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message FWM-3-FCFIB_NO_MEM: Out of memoryExplanation Fcfib does not have enough memory to continue proper operation.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Either fcfib was not scheduled to run, or fcfib was busy, and fcfib did not service the message or timer queue for an extended period.
Recommended Action Please perform 'debug fwm error', then recreate the operation scenario, to find out more details.
Error Message FWM-4-FWM_DUPLICATE_UNICAST_MAC_REGISTRATION: Unicast MAC address [chars] vlan [dec] registered on interface [chars] before deregistering on interface [chars]Explanation Duplicat unicast MAC registration observed
Recommended Action No action is required.
Error Message FWM-4-STM_LEARNING_OVERLOAD: [chars]Explanation System getting overloaded due to learning processes
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Notification of a MAC address moving as per configuration
Recommended Action No action is required.
Error Message FWM-6-STM_THRESHOLD_NOTIFICATION: Station table reached [dec]% of the total capacity (total entries [dec])Explanation Station table capacity utilization message as per configured threshold values
Recommended Action No action is required.
Error Message FWM-6-UUFB_CHANGE_NOTIFICATION: Unknown unicast flood blocking has been [chars]Explanation Notification of unknown unicast flood blocking being enabled or disabled
Explanation Unicast routing initialization failed and the GLBP process terminated
Recommended Action Please check syslog messages for URIB failures and rectify the problem
Explanation The system was unable to add the GLBP vIP into the arp table
Recommended Action Please check syslog messages for ARP failures and rectify the problem
Error Message GLBP-3-GLBP_ARP_DEL_FAILED: failed to delete [chars]/[chars] in arp tableExplanation The system was unable to delete the GLBP vIP from the arp table
Recommended Action Please check syslog messages for ARP failures and rectify the problem
Error Message GLBP-3-GLBP_FEATURE_MANAGER_ERROR: [chars]: [chars]Explanation There was a problem in GLBP interaction with feature manager.
Recommended Action Please check the reason for error using feature manager and rectify the problem
Error Message GLBP-3-GLBP_IP_JOIN_GROUP_FAILED: [chars]: failed to join glbp multicast address groupExplanation The system was unable to peform a join to start receiving GLBP protocol packets.
Recommended Action Please check syslog messages for IP failures and rectify the problem
Error Message GLBP-3-GLBP_IP_LEAVE_GROUP_FAILED: [chars]: failed to leave glbp multicast address groupExplanation The system was unable to peform a leave to stop receiving GLBP protocol packets.
Recommended Action Please check syslog messages for IP failures and rectify the problem
Error Message GLBP-3-GLBP_MAC_ADD_FAILED: fwd [dec] failed to add [chars] in mac table (error [hex])Explanation The system was unable to add the GLBP mac address into the mac addresss table
Recommended Action Please check syslog messages for L2FM failures and rectify the problem
Error Message GLBP-3-GLBP_MAC_DEL_FAILED: fwd [dec] failed to delete [chars] in mac table (error [hex])Explanation The system was unable to delete the GLBP mac address from the mac addresss table
Recommended Action Please check syslog messages for L2FM failures and rectify the problem
Error Message GLBP-3-GLBP_ROUTE_ADD_FAILED: failed to add [chars] in routing tableExplanation The system was unable to add the GLBP vIP address into the unicast routing table
Recommended Action Please check syslog messages for URIB failures and rectify the problem
Error Message GLBP-3-GLBP_ROUTE_DEL_FAILED: failed to delete [chars] in routing tableExplanation The system was unable to delete the GLBP vIP address from the unicast routing table
Recommended Action Please check syslog messages for URIB failures and rectify the problem
Explanation Two routers participating in a Gateway Load Balancing Protocol group have a valid authentication string that does not match.
Recommended Action Use the glbp authentication interface command to repair the Gateway Load Balancing Protocol authentication discrepancy between the local system and the one whose IP address is reported
Error Message GLBP-4-BADVIP1: address [chars] is in the wrong subnet for this interfaceExplanation The Gateway Load Balancing Protocol virtual IP address is not within the subnet configured on this interface.
Recommended Action Configure the virtual IP address of Gateway Load Balancing Protocol to be within the subnet configured on this interface.
Error Message GLBP-4-BADVIP2: address [chars] in the wrong subnet for this interface is not learnedExplanation The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is not within the subnet configured on this interface.
Recommended Action Check the configuration on all Gateway Load Balancing Protocol routers.
Error Message GLBP-4-BADVIP3: address [chars] is the broadcast address for this interfaceExplanation The Gateway Load Balancing Protocol virtual IP address is a broadcast address for this interface.
Recommended Action Configure the virtual IP address of Gateway Load Balancing Protocol to be a non broadcast address.
Error Message GLBP-4-DIFFVIP1: active router virtual IP address [chars] is different from the locally configured virtual IP address [chars]Explanation The Gateway Load Balancing Protocol virtual IP address contained in the Hello message from the Active router is different to that configured locally.
Recommended Action Check the configuration on all Gateway Load Balancing Protocol routers
Error Message GLBP-4-DUPADDR: Duplicate address on [chars]Explanation The IP address in a Gateway Load Balancing Protocol message received on the interface is the same as the IP address of its own router. This condition may be caused by a misconfiguration or because of a malfunctioning switch.
Recommended Action Check the configurations on all the Gateway Load Balancing Protocol routers, and ensure that any switches are functioning properly
Error Message GLBP-4-DUPVIP1: address [chars] already assigned to interface [chars] grp [dec]Explanation The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to a different Gateway Load Balancing Protocol group.
Recommended Action Check the configuration on all Gateway Load Balancing Protocol routers
Error Message GLBP-4-DUPVIP2: address [chars] already assigned to this interfaceExplanation The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to this interface.
Recommended Action Check the configuration on all Gateway Load Balancing Protocol routers.
Error Message GLBP-4-DUPVIP3: address [chars] already assigned to another interface [chars]Explanation The Gateway Load Balancing Protocol virtual IP address contained in the hello message cannot be learned. It is already assigned to, or overlaps with, an address on another interface or application.
Recommended Action Check the configuration on all Gateway Load Balancing Protocol routers.
Error Message GLBP-4-GLBP_ARP_RESP_FAILED: failed to send arp response [chars]/[chars]Explanation The system was unable to send the arp response for vIP
Recommended Action Please check syslog messages for ARP failures and rectify the problem
Explanation The Gateway Load Balancing Protocol has changed active gateway.
Recommended Action No action is required
Error Message GLBP-5-FWDSTATECHANGE: fwd [dec] state changed from [chars] to [chars]Explanation The Gateway Load Balancing Protocol forwarder has changed state.
Recommended Action No action is required
Error Message GLBP-5-FWD_CREATE: fwd [dec] createdExplanation The Gateway Load Balancing Protocol forwarder has been created.
Recommended Action No action is required
Error Message GLBP-5-FWD_DELETE: fwd [dec] deletedExplanation The Gateway Load Balancing Protocol forwarder has been removed.
Recommended Action No action is required
Error Message GLBP-5-FWD_OWNER: fwd [dec] owner mac is [chars]Explanation The Gateway Load Balancing Protocol forwarder has changed the owner MAC address.
Recommended Action No action is required
Error Message GLBP-5-FWD_VMAC: fwd [dec] virtual mac is [chars]Explanation The Gateway Load Balancing Protocol forwarder has changed the virtual MAC address.
Recommended Action No action is required
Error Message GLBP-5-FWD_WEIGHTING: fwd [dec] weighting is [dec]Explanation The Gateway Load Balancing Protocol forwarder has changed the weighting.
Recommended Action No action is required
Error Message GLBP-5-GRPSTATECHANGE: state changed from [chars] to [chars]Explanation The Gateway Load Balancing Protocol gateway has changed state.
Recommended Action No action is required
Error Message GLBP-5-MEMBER_ADD: member [chars] [chars] addedExplanation The Gateway Load Balancing Protocol gateway has added a member.
Recommended Action No action is required
Error Message GLBP-5-MEMBER_REMOVE: member [chars] [chars] removedExplanation The Gateway Load Balancing Protocol gateway has removed a member.
Recommended Action No action is required
Error Message GLBP-5-PRIORITY: [chars] gateway priority changed to [dec]Explanation The Gateway Load Balancing Protocol gateway has changed priority.
Recommended Action No action is required
Error Message GLBP-5-STANDBY_CHANGE: Standby gateway is [chars]Explanation The Gateway Load Balancing Protocol has changed standby gateway.
Recommended Action No action is required
Error Message GLBP-5-TIMER: [chars] timer changed to [chars]Explanation The Gateway Load Balancing Protocol gateway has learnt timers.
Recommended Action No action is required
Error Message GLBP-5-VIPLEARN: learnt virtual ip address [chars]Explanation The Gateway Load Balancing Protocol gateway has learnt virtual IP address.
Recommended Action No action is required
Error Message GLBP-5-VIPUNLEARN: unlearnt virtual ip address [chars]Explanation The Gateway Load Balancing Protocol gateway has unlearnt virtual IP address.
Recommended Action No action is required
Error Message GLBP-5-WEIGHTING: weighting changed to [dec]Explanation The Gateway Load Balancing Protocol gateway has changed the weighting.
Explanation Refer logs for more details
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-BFD_IF_SESSION_REMOVAL_ERROR: Failed to remove few HSRP-BFD sessions([hex] [hex]), Refer logsExplanation Refer logs for more details.
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-BFD_SESSION_ADD_ERROR: Failed to add few HSRP-BFD sessions([hex] [hex]), Refer logsExplanation TRefer logs for more details.
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-BFD_SESSION_CREATION_ERROR: Failed to create BFD session information([hex] [hex]), Refer logsExplanation Refer logs for more details.
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-BFD_SESSION_REMOVAL_ERROR: Failed to remove few HSRP-BFD sessions([hex] [hex]), Refer logsExplanation Refer logs for more details.
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-ERROR_IN_ADD_VIP_TO_U6RIB: Failed to Add VIP [chars] to U6RIB (errno [hex]), Refer logsExplanation Refer logs for more details.
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-ERROR_IN_DEL_VIP_FROM_U6RIB: Failed to delete VIP [chars] from U6RIB (errno [hex]), Refer logsExplanation Refer logs for more details.
Recommended Action No action is required.
Error Message HSRP_ENGINE-3-NOSOCKET: Unable to open socketExplanation The system was unable to initialize an IP connection for the Hot Standby protocol.
Recommended Action Make sure that there is at least one interface configured to run IP.
Explanation Two routers participating in HSRP disagree on the valid authentication string.
Recommended Action Use the HSRP authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported.
Error Message HSRP_ENGINE-4-BADAUTH: Bad authentication from [chars], group [dec], remote state [chars]Explanation Two routers participating in HSRP disagree on the valid authentication string.
Recommended Action Use the HSRP authentication command to repair the HSRP authentication discrepancy between the local system and the one whose IP address is reported.
Error Message HSRP_ENGINE-4-DIFFVIP1: [chars] Grp [dec] active routers virtual IP address [chars] is different to the locally configured address [chars]Explanation The HSRP virtual IP address contained in the Hello message from the Active router is different to that configured locally.
Recommended Action Check the configuration on all HSRP routers.
Error Message HSRP_ENGINE-4-DUPADDR: Duplicate address %i on [chars], sourced by %eExplanation The IP address in an HSRP message received on the interface is the same as the router's own IP address. This may be because of misconfiugration, or because of a malfunctioning switch
Recommended Action Check the configurations on all the HSRP routers, and make sure that any switches you have are functioning properly.
Error Message HSRP_ENGINE-4-DUPVIP1: [chars] Grp [dec] address [chars] is already assigned to a HSRP group on this interfaceExplanation The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to a different HSRP group.
Recommended Action Check the configuration on all HSRP routers.
Error Message HSRP_ENGINE-4-DUPVIP2: [chars] Grp [dec] address [chars] is already assigned on this interfaceExplanation The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to this interface.
Recommended Action Check the configuration on all HSRP routers.
Error Message HSRP_ENGINE-4-DUPVIP3: [chars] Grp [dec] address [chars] is already assigned to, or overlaps with, an address on another interface or applicationExplanation The HSRP virtual IP address contained in the Hello message cannot be learnt as it is already assigned to, or overlaps with, an address on another interface or application.
Recommended Action Check the configuration on all HSRP routers.
Explanation The priority of the Active router for the group has changed.
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-ACTIVE_CHANGE: Interface [chars] [chars] Grp [dec] Active router is [chars]Explanation The Active router for the group has changed.
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-AUTOCONFIG_VIPLEARN: Interface [chars] grp [dec] learnt autoconfig virtual ip address [chars]Explanation The local router has generate virtual ip address
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-GRPSTATECHANGE: Interface [chars] [chars] Grp [dec] state changed from [chars] to [chars] reason [chars]Explanation The HSRP router has changed state
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-MACADDRESS_CHANGE: Interface [chars] [chars] Grp [dec] mac-address changed to [chars]Explanation The mac address of the group has changed.
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-PRIORITY: Interface [chars] [chars] Grp [dec] priority changed to [dec]Explanation The current priority of the HSRP group has changed.
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-STANDBYROUTERPRIORITYCHANGE: Interface [chars] [chars] Grp [dec] Standby router priority changed to [dec]Explanation The priority of the Standby router for the group has changed.
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-STANDBY_CHANGE: Interface [chars] [chars] Grp [dec] Standby router is [chars]Explanation The Standby router for the group has changed.
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-STATECHANGE2: [chars] [chars] Grp [dec] state moving from [chars]Explanation The router has changed state
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-STATECHANGE: [chars] [chars] Grp [dec] state move to [chars]Explanation The router has changed state
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-TIMER: Interface [chars] [chars] Grp [dec] [chars] timer changed to [dec] [chars]Explanation The hello/hold timer value for the HSRP group has changed
Recommended Action No action is required.
Error Message HSRP_ENGINE-6-VIPLEARN: Interface [chars] [chars] Grp [dec] learnt virtual ip address [chars]Explanation The local router has learnt virtual ip address from the incoming HSRP packet.
Explanation Crypto initialization error
Recommended Action No action is required.
Error Message IKE-3-ENABLE_ERROR: Unable to store enable flag in configuration (error-id [hex]).Explanation Service failed to store the enable flag in configuration. As a result, it will exit
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IKE-3-FIPS_MODE_ERROR: Could not set FIPS modeExplanation The FIPS mode could not be set by IKE
Recommended Action No action is required.
Error Message IKE-3-IKE_PROGRAM_EXIT: [chars]Explanation IKE process did an abnormal exit
Recommended Action No action is required.
Error Message IKE-3-MAX_HALF_CONN_LIMIT_REACHED: IKEv1 : Exceeded the limit for number of half open Phase 1 connectionsExplanation The number of half open connections has exceeded the maximum limit
Recommended Action No action is required.
Error Message IKE-3-PHASE1_NEGOTIATION_FAILED: IKEv1: Phase 1 negotiation failed for peer [chars]Explanation IKE policy negotiation failed for peer [chars].
Recommended Action No action is required.
Error Message IKE-3-PHASE1_PROPOSAL_MISMATCH: IKEv1: No matching phase 1 proposal found for peer [chars]Explanation There is a IKE policy mismatch for the peer.
Recommended Action No action is required.
Error Message IKE-3-PHASE2_NEGOTIATION_FAILED: IKEv1: Phase 2 negotiation failed for peer [chars]Explanation IPsec policy negotiation failed for peer [chars].
Recommended Action No action is required.
Error Message IKE-3-PHASE2_PROPOSAL_MISMATCH: IKEv1: No matching phase 2 proposal found for peer [chars]Explanation There is a IPsec policy mismatch for the peer.
Recommended Action No action is required.
Error Message IKE-3-UNSUPPORTED_EXCHANGE: IKEv1: Unsupported exchange [dec] received from [chars]Explanation A unsupported IKE exchange type [digits] was received from [chars]
Explanation Received a payload in an inappropriate exchange
Recommended Action No action is required.
Error Message IKE-4-MESSAGE_ERROR: IKEv2 message (from [chars]) message error: [chars]Explanation Received a malformed message which doesn't adhere to the protocol
Recommended Action No action is required.
Error Message IKE-4-PARSING_ERROR: IKEv2 message (from [chars]) parsing error: [chars]Explanation Received a malformed message which can not be parsed appropriately
Recommended Action No action is required.
Error Message IKE-4-UNKNOWN_PAYLOAD: IKEv2 received message (from [chars]) with un-recognized payload ([chars])Explanation Received an invalid payload
Recommended Action No action is required.
Error Message IKE-4-UNSUPPORT: [chars] is not supported (message from [chars])Explanation IKE is exiting since it is not enabled in the configuration
Explanation Ilc_span_mgr encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation SSE License has expired, hence the linecard will be rebooted.
Recommended Action Install appropriate SSE license to be able to use SSM features normally
Explanation The ssi boot variable is configured to an invalid image. So, the linecard will be bought online in basic mode instead of advanced SSI mode
Recommended Action Configure a proper image for the ssi boot variable
Explanation A valid license has been obtained for the SSM
Recommended Action No action is required.
Error Message ILC_HELPER-6-UPGRADE_DELAY: The SSI upgrade on slot [dec] is delayed by [dec] secs.Explanation The SSI upgrade is delayed due to the configured ssm upgrade delay command
Explanation Addon image download to module failed. This module is not operational until an addon image has been successfully installed.
Recommended Action Verify the location and version of your module image. Use the install module cli command to download a new module image.
Error Message IMAGE_DNLD-SLOT#-2-IMG_DNLD_COMPLETE: Module image download process. [chars]Explanation Image download completed. Module image is being installed.
Recommended Action No action is required.
Error Message IMAGE_DNLD-SLOT#-2-IMG_DNLD_FAILED: Module image download process. [chars]Explanation Image download failed. Module may be inoperable.
Recommended Action Use show module cli command to verify the state of this module. Retry image download with install module cli command.
Error Message IMAGE_DNLD-SLOT#-2-IMG_DNLD_FILE_SYSTEM_CHECK_ERROR: File System check failed: [chars]Explanation File system consistency check failed
Recommended Action File-system repair is needed using fsck
Error Message IMAGE_DNLD-SLOT#-2-IMG_DNLD_STARTED: Module image download process. [chars]Explanation Image download started. Module image downloads are non-disruptive to module operation.
Explanation File system checking and recreation if necessary for \/images\.
Explanation Addon image download to module has completed.The module should now be installing this new image.
Recommended Action This message is informational only.
Error Message IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_STARTED: Addon module image download process started. [chars]Explanation Addon image download to module has started. This is a disruptive download and this module will be inoperable until this download process is complete.
Recommended Action This message is informational only.
Error Message IMAGE_DNLD-SLOT#-5-ADDON_IMG_DNLD_SUCCESSFUL: Addon module image download and install process successful. [chars]Explanation Addon image download and install to module is successful.
Recommended Action Use the show module cli command to verify the module's operational status.
Explanation LC Offline was not relayed to some vdc, so applications may not behave correctly.
Recommended Action No action is required.
Error Message IM-3-IM_RESP_ERROR: Component [chars] opcode:[chars] in vdc:[dec] returned error:[chars]Explanation Some component returned an error.
Recommended Action No action is required.
Error Message IM-3-IM_SEQ_ERROR: Error ([chars]) while communicating with component [chars] opcode:[chars] (for:[chars])Explanation Some component did not respond to a request in stipulated time.
Explanation Demux function returned error
Recommended Action No action is required.
Error Message IM-5-IM_INTERNAL_ERROR: [chars]Explanation Internal error occurred
Recommended Action No action is required.
Error Message IM-5-IM_INTF_STATE: [chars] [chars] in vdc [dec]Explanation Management interface state changed.
Recommended Action No action is required.
Error Message IM-5-IM_UNKNOWN_INTERFACE: [chars]Explanation Interface has been configured to be administratively down
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-IF_DOWN_ERROR_DISABLED: Interface [chars] is down. Reason [dec]Explanation The interface encountered an error while configuring it
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-IF_DOWN_INACTIVE: Interface [chars] is down (Inactive)Explanation Interface VLAN has been suspended or deleted
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_DISABLED: SVI DisabledExplanation SVI Service Disabled
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_ENABLED: SVI EnabledExplanation SVI Service Enabled
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_GET_MAC_FAILED: Failed to acquire MAC address for SVI [hex]Explanation SVI failed to acquire MAC address
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_INIT: SVI intialization failed with error [hex]Explanation SVI initialziation error
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_IOD_RELEASE_ERROR_RESPONSE: IM failed to release SVI IOD error [hex]Explanation IM failed to release SVI IOD
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_MTS_SEND_FAILURE: MTS send failure for opcode [dec], error [hex]Explanation SVI encountered an error in with MTS message
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_MTS_TIME_OUT: MTS send timed outExplanation SVI did not recieve response for mts message
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_RSRVD_VLAN_FAILED: Failed to get list of reserved vlans [hex]Explanation SVI failed to get the list reserved vlans
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_SDB_UPDATE_FAILED: sdb update failed with ret_val [dec]Explanation SDB updated failed for SVI
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-SVI_SEC_VLAN_FAILED: Failed to get list of secondary vlans [hex]Explanation SVI failed to get the list of secondary vlans
Recommended Action No action is required.
Error Message INTERFACE_VLAN-5-UPDOWN: Line Protocol on Interface [chars], changed state to [chars]Explanation IOA Service Disabled
Recommended Action No action is required.
Error Message IOA_LC-5-IOA_ENABLED: IOA EnabledExplanation Ipacl caused a system failure
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Ipacl caused failures in other services
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Ipacl encountered a catastrophic error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Ipacl encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Ipacl ignored the unexpected condition
Recommended Action Please perform 'debug ipacl all', then recreate the operation scenario, to find out more details.
Explanation Ipacl does not support this operation
Recommended Action Please perform 'debug ipacl all', then recreate the operation scenario, to find out more details.
Explanation The service failed to allocate a block of dynamic memory.
Explanation The service failed to start. The failure occurred while initializing the component [chars].
Recommended Action Show processes to check the status of the other processes, debug the specified component.
Error Message IPFC-3-IOCTL_FAILED: IOCTL failedExplanation An IOCTL to the character device failed.
Recommended Action Show IPFC internal interface VSAN <number> for all the configured VSAN interfaces to check the internal status, show IPFC internal MIP to check the internal status.
Error Message IPFC-3-PSSERROR: [chars]Explanation The specified VSAN Interface has been successfully [chars].
Recommended Action No action is required.
Error Message IPFC-5-STATE_CHANGE: VSAN interface [dec] [chars]Explanation Failed to do high availability operation. [chars] is the reason.
Recommended Action No action is required.
Error Message IPQOSMGR-2-QOSMGR_INIT_FAILED: Initialization failed for QoS Manager: [chars], reason: [hex].Explanation Initialization failed for QoS Manager due to [chars], reason: [hex].
Recommended Action No action is required.
Error Message IPQOSMGR-2-QOSMGR_MTS_FAILURE: Failed to do MTS operation: [chars].Explanation Failed to do MTS operation. [chars] is the reason.
Recommended Action No action is required.
Error Message IPQOSMGR-2-QOSMGR_MTS_REGISTRATION_FAILED: MTS options setting to [hex] failed for opCode: [dec].Explanation MTS options setting to [hex] failed for opCode: [dec].
Recommended Action No action is required.
Error Message IPQOSMGR-2-QOSMGR_PSS_FAILURE: Failed to do PSS operation: [chars], reason: [hex].Explanation Failed to do PSS operation [chars]. [hex] is the reason.
Recommended Action No action is required.
Error Message IPQOSMGR-2-QOSMGR_PSS_VER_FAIL: PSS file [chars] has version [dec].[dec].[dec], expected version [dec].[dec].[dec].Explanation There was a mismatch in the PSS version. [chars] indicates the PSS service, [dec].[dec].[dec] its current version number and [dec].[dec].[dec] the expected version.
Explanation Configuration error. [chars] is the reason.
Recommended Action No action is required.
Error Message IPQOSMGR-3-QOSMGR_PPF_ERROR: PPF library error: [chars].Explanation Dcbxp warning: Port_id [chars] has dce config [chars] which is incompatible with the peer.
Recommended Action No action is required.
Error Message IPQOSMGR-4-QOSMGR_LC_ERROR_MSG: Linecard [dec] returned an error: [chars]Explanation Linecard [dec] returned an error message which is reported as [chars].
Recommended Action No action is required.
Error Message IPQOSMGR-4-QOSMGR_PPF_WARNING: PPF library warning: [chars].Explanation PPF library warning. [chars] is the reason.
Recommended Action No action is required.
Error Message IPQOSMGR-4-QOSMGR_WARNING_MSG: [chars] [dec]Explanation QOSMGR warning messages is reported as [chars] [dec].
Explanation Linecard [dec] returned an error message for session of type [chars] which is reported as [chars]. This message may be seen during linecard reload if there is an active session going on.
Explanation Dcbxp warning: Port_id [chars] has qos config [chars] which is incompatible with the peer.
Recommended Action No action is required.
Error Message IPQOSMGR-6-QOSMGR_STATUS: QOSMGR Status: [chars].Explanation An error occured in the DPA [string] is the error message.
Explanation IPSec initialization failed
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPSEC-2-IPSEC_SPD_OVERFLOW_DUE_TO_ACL: SPD Overflow on interface due to IP ACL [chars] bound to crypto map [chars] [dec]Explanation Modifying IP ACL caused Security Policy Database on the interface to overflow, IP ACL filter not applied to security policy database
Explanation Packets dropped in the 14/2 module. Please collect drop statistics using \show ipsec internal crypto-acc interface gigabit <slot/port> stats\
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPSEC-3-IPSEC_FIPS_TEST_FAILED: IPSEC FIPS compliance test failedExplanation IPSEC FIPS compliance test failed
Recommended Action No action is required.
Error Message IPSEC-3-IPSEC_MSG_SEND_FAILURE: failed to send [chars] to sap [dec]: [chars]Explanation IP ACL updated while it is mapped to a crypto map that is bound to interface(s)
Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_DISABLED_LIC_EXPIRED: IPSec Disabled due to License ExpiryExplanation IPSec Disabled due to License Expiry
Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_DISABLED: IPSec DisabledRecommended Action No action is required.
Error Message IPSEC-5-IPSEC_ENABLED: IPSec EnabledRecommended Action No action is required.
Error Message IPSEC-5-IPSEC_SA_CREATED: [chars]: IPSec SA created: local_ip: [chars], peer_ip: [chars], [chars] SPI: [dec] ([hex])Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_SA_DELETED: [chars]: IPSec SA deleted: local_ip: [chars], peer_ip: [chars], [chars] SPI: [dec] ([hex]), reason: [chars]Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_SA_REKEYED: [chars]: IPSec SA rekeyed: local_ip: [chars], peer_ip: [chars], [chars] SPI: [dec] ([hex])Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_TUNNEL_CREATED: [chars]: IPSec tunnel created: local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars], traffic:: local: [chars]/[chars], port: [chars], remote: [chars]/[chars], ports: [chars]Explanation IPSec tunnel created
Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_TUNNEL_DELETED: [chars]: IPSec tunnel deleted: local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars], traffic:: local: [chars]/[chars], ports: [chars] remote: [chars]/[chars], ports: [chars]Explanation IPSec tunnel deleted
Recommended Action No action is required.
Error Message IPSEC-5-IPSEC_TUNNEL_REKEYED: [chars]: IPSec tunnel rekeyed: local_ip: [chars], peer_ip: [chars], id: [dec], protocol: [chars] traffic:: local: [chars]/[chars], ports: [chars] remote: [chars]/[chars], ports: [chars]Explanation Node is not incrementing heartbeats periodically
Recommended Action Potential node software issue. Please contact your support representative
Error Message IPS_SB_MGR-SLOT#-2-NODE_NOT_RESPONDING: [Node [dec], Core [dec]] : Not responding to heartbeatsExplanation Node manager is not receiving heartbeat responses from the node
Recommended Action Potential node software issue. Please contact your support representative
Error Message IPS_SB_MGR-SLOT#-2-NODE_REIMAGE_PREPARE_FAIL: [Node [dec]]: Disk formatting failed during node installExplanation There was a problem during the partitioning of disk and creation of file systems during node install.
Recommended Action Potential node software issue. Please contact your support representative
Error Message IPS_SB_MGR-SLOT#-2-PORT_SOFTWARE_FAILURE: Port software failure, module [dec] port [dec]Explanation The software servicing the data path on the port has failed
Explanation The compression engine did not respond to heartbeats, due to some failure. SAN-OS will restart the compression engine to clear the problem.
Recommended Action No action is required.
Error Message IPS_SB_MGR-SLOT#-3-CRYPTO_FAILURE: Heartbeat failure in encryption engine (error [hex])Explanation The encryption engine did not respond to heartbeats, due to some failure. SAN-OS will restart the encryption engine to clear the problem.
Recommended Action No action is required.
Error Message IPS_SB_MGR-SLOT#-3-FIPS_SELF_TEST_FAILURE: [chars] Restarting the octeon...Explanation FIPS self test failed for the algorithm. Restarting the octeon.
Explanation The svc image on the node is not compatible with the add on image running on the linecard.
Recommended Action Please contact your support representative
Error Message IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_CURRENT: svc-node[dec] image is not compatible with current node imageExplanation The new svc image is not compatible with the svc image currently running on the node
Recommended Action Please contact your support representative
Error Message IPS_SB_MGR-SLOT#-4-NODE_NOT_COMPAT_WITH_SUP: svc-node[dec] image is not compatible with system imageExplanation The svc image on the node is not compatible with the supervisor image.
Recommended Action Please contact your support representative
Explanation This is an event log of sb_mgr relating to a port/node
Explanation IPS initialization failed
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation FTA Exch being aborted
Recommended Action Informational no action required
Error Message IPS-3-FCIP_FTA_DATA_SENSE: Sense data with ERA [hex] sent to CH FCID: [hex] CHI: [hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation Sense data with ERA sent
Recommended Action SYSLOGDOC_CONTACT_TAC
Error Message IPS-3-FCIP_FTA_ERA_35: ERA 0x35 presented to CH FCID: [hex] CHI: [hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP got an ERA 35
Recommended Action SYSLOGDOC_CONTACT_TAC
Error Message IPS-3-FCIP_FTA_ERA_38: ERA 0x38 received CH FCID: [hex] CHI: [hex] from FCIP CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] at tape capacity: [dec] MBExplanation FCIP got an ERA 38
Recommended Action SYSLOGDOC_CONTACT_TAC
Error Message IPS-3-FCIP_FTA_LOCATE_RBID_MISMATCH: Permanent Error due to Locate RBID Mismatch, CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP-FTA got a Permanent Error
Recommended Action Informational no action required
Error Message IPS-3-FCIP_FTA_PERM_ERR: Permanent Error, ERA [hex] rcvd CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] sense_byte[2,6]: [[hex], [hex]]Explanation FCIP-FTA got a Permanent Error
Recommended Action Informational no action required
Error Message IPS-3-FCIP_FTA_RETRY_ERROR: [chars] retries [dec] FC oxid [hex] My oxid [hex] State [chars] Event [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FTA Command timed out
Recommended Action Informational no action required
Error Message IPS-3-IPS_CRYPTO_FIPS_FAILED: IPS module [dec] has failed FIPS tests. FIPS info - [chars]Explanation FIPS error occurred in the IPS module.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-IPS_EGRESS_PERR: Parity error on dma-bridge egress. Count: [dec]Explanation Parity error occured in dma-bridge egress direction.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-IPS_FIPS_MODE_ERROR: IPS FIPS error: [chars]Explanation IPS module FIPS mode error
Recommended Action No action is required.
Error Message IPS-3-IPS_FIPS_TEST_FAILED: IPS FIPS compliance test failedExplanation IPS FIPS compliance test failed
Recommended Action No action is required.
Error Message IPS-3-IPS_INGRESS_PERR: Parity error on dma-bridge ingress. Count: [dec]Explanation Parity error occured in dma-bridge ingress direction.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_CLEAR_FAILED: [chars]Explanation An error occurred while clearing the CFS lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_COMMIT_FAILED: [chars]; [chars]Explanation An error occurred while commiting the cfs config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_CONFIG_FAILED: [chars]; [chars]Explanation An error occurred while distributing the CFS config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_LOCK_FAILED: [chars]Explanation An error occurred while acquiring the CFS lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_ACTIVATION_FAILED: [chars]; [chars]Explanation An error occurred while activating merged configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_CLEARED: [chars]Explanation Merge cleared, reason: [chars]
Recommended Action No action is required.
Error Message IPS-3-ISLB_CFS_MERGE_COMMIT_FAILED: [chars]; [chars]Explanation An error occurred while commiting the cfs merge config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_CONFIG_FAILED: [chars]; [chars]Explanation An error occurred while distributing the CFS merge config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_FAILED: [chars]; [chars]Explanation An error occurred while merging the iSLB CFS fabrics. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_PRECOMMIT_FAILED: [chars]; [chars]Explanation An error occurred while precommiting merge data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_MERGE_REQ_REJECTED: [chars]Explanation Merge requested rejected, reason: [chars]
Recommended Action No action is required.
Error Message IPS-3-ISLB_CFS_MERGING_CONFIG_DB_FAILED: [chars]; [chars]Explanation An error occurred while merging the config data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_PRECOMMIT_FAILED: [chars]; [chars]Explanation An error occurred while precommiting data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_PWWN_RESV_CLAIM_FAILED: [chars]Explanation PWWN reservation claim failed. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_PWWN_RESV_RELEASE_FAILED: [chars]Explanation PWWN reservation release failed. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_UNLOCK_FAILED: [chars]Explanation An error occurred while releasing the CFS lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_CFS_VRRP_DIST_FAILED: [chars]Explanation An error occurred while distributing the VRRP CFS runtime data. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_ZONE_ACTIVATION_FAILED: iSLB zoneset activation returned [hex] for VSAN [dec]Explanation ISLB zoneset activation failed.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IPS-3-ISLB_ZONE_ACTIVATION_RETRY: iSLB zoneset activation returned [hex] for VSAN [dec]Explanation ISLB zoneset activation failed. Zone server busy.
Recommended Action Retry the iSLB zonest activation.
Error Message IPS-3-ISLB_ZONE_NO_ACTIVE_ZONESET: iSLB zoneset activation returned [hex] for VSAN [dec]Explanation ISLB zoneset activation failed. No active zoneset.
Recommended Action Activate a zoneset in the specified VSAN and retry
Error Message IPS-3-RED_PACKET_DROPS: Congestion detected on GigabitEthernet port (buffer pool size: [dec])Explanation Congestion detected on GigabitEthernet port due to RED threshold limit
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation The FCIP Ficon Tape Acceleration configuration does not match with peer's configuration
Recommended Action Fix the FCIP Ficon Tape Acceleration configuration to be consistent with the peer
Error Message IPS-4-FCIP_FTA_VSAN_UPDATE_WARNING: FCIP FICON tape acceleration VSAN update had an error ([chars]) on interface [chars] causing a flap of the interfaceExplanation The FCIP FICON tape acceleration VSAN configuration experienced an error when disabling and enabling the VSAN over the FCIP tunnel. The FCIP tunnel was disabled and re-enabled as a result of this error to ensure data integrity.
Recommended Action No action is required.
Error Message IPS-4-FCIP_LICENSE_BIND_FAILED: Bind failed for [chars] due to [chars] for license failure; configuration accepted but bind failedExplanation The FCIP configuration was accepted, but the FCIP interface did not bind to a physical interface because the appropriate license was not available. If a license becomes available in the future, this FCIP interface will bind to a physical interface automatically.
Recommended Action Check the license state with show license usage and acquire the necessary FCIP license
Error Message IPS-4-FCIP_XRCE_LICENSE_FAILED: XRC Acceleration deactivated due to license failureExplanation The XRC Acceleration configuration was accepted, but will remain inactive until a valid license is available. When the appropriate license is installed, XRC accelaration will be activated.
Recommended Action Check the license state with show license usage and acquire the necessary XRC_ACCL license
Error Message IPS-4-FCIP_XRCE_LICENSE_INSTALLED: XRC Acceleration activated due to valid licenseExplanation The XRC Acceleration configuration is activated as a valid license has been installed.
Explanation FCIP/ISCSI Interface bind to Ethernet port failed
Recommended Action No action is required.
Error Message IPS-5-FCIP_BPORT_KEEPALIVES_NOT_SUPPORTED: Bport Keepalives not supported for FCIP [chars]Explanation Bport Keepalives not supported in this release
Recommended Action Informational no action required
Error Message IPS-5-FCIP_BPORT_NOT_SUPPORTED: Bport not supported for FCIP [chars]Explanation Bport not supported in this releas
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_ALREADY_OFF: FTA Already Off, [chars] VSAN: [dec]Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_ALREADY_ON: FTA Already ON, [chars] VSAN: [dec]Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_CB_DOWN: FTA [chars] is DOWNRecommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_CB_UP: FTA [chars], is UPRecommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_DISBAND_GRP_CMD: Disband Group message processed PGID: [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP Disbanded a Group
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_EST_GRP_CMD: Path Group establised for PGID: [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP established a Path Group
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_NPORT_PATH_RSCN_CLNUP_PASS1: RSCN Cleanup Pass1 [chars] FCID1: [hex] FCID2: [hex] VSAN: [dec]Explanation Doing RSCN Cleanup, Pass 1
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_NPORT_PATH_RSCN_CLNUP_PASS2: RSCN Cleanup Pass2 [chars] FCID1: [hex] FCID2: [hex] VSAN: [dec]Explanation Doing RSCN Cleanup, Pass 2
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_RESIGN_GRP_CMD: Resign group processed for PGID: [chars] CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP Resigned a Group
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_RESP_3490: 3490 device discovered by FCIP CH FCID: [hex] CHI: [hex] device at CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation Device type discovered is 3490
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_RESP_3590: 3590 device discovered by FCIP CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation Device type discovered is 3590
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_RESP_NOT_TAPE: Non-tape device discovered by FCIP CH FCID: [hex] CHI: [hex] device at CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP discovered a non-tape device
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_TURN_OFF_LAST_VSAN: FTA turned off for the Last VSAN, [chars] VSAN: [dec]Explanation FTA turned off for the Last Vsan
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_TURN_OFF_NONLAST_VSAN: FTA turned off for the Non-Last VSAN, [chars] VSAN: [dec]Explanation FTA turned off for the Non-Last Vsan
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_TURN_ON: Turn ON FTA, [chars] VSAN: [dec]Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTA_WARNING: FTA Warning :[chars]Explanation Generic FTA Warning
Recommended Action Informational no action required
Error Message IPS-5-FCIP_FTRA_CFG_MISMATCH: [chars]: Mismatch in FCIP FICON Tape Read Accelerator configuration with peerExplanation The FCIP FICON Tape Read Accelerator configuration does not match with peer's configuration
Recommended Action Fix the FCIP FICON Tape Read Accelerator configuration to be consistent with the peer
Error Message IPS-5-FCIP_IF_CR_DEL: Interface [chars] [chars]Explanation FCIP Interface was Created or Deleted
Recommended Action No action is required.
Error Message IPS-5-FCIP_MODE1_CHANGED_TO_MODE2: Changing mode1 compression to mode2 for [chars], on a MSM/SSN-16 linecardExplanation Change mode1 compression to mode2 on a MSM/SSN-16 linecard
Recommended Action Informational no action required
Error Message IPS-5-FCIP_NUM_TCP_CONNS_MISMATCH: [chars]: configured for 2 tcp connections but currently operating with 1 connectionExplanation Number of configured tcp connections don't match number of connections currently up
Recommended Action No action is required.
Error Message IPS-5-FCIP_PEER_CAVIUM: Peer FCIP [chars] is a MSM/SSN-16 linecardExplanation Peer linecard is a MSM/SSN-16
Recommended Action Informational no action required
Error Message IPS-5-FCIP_PEER_NON_CAVIUM: Peer FCIP [chars] is a non MSM/SSN-16 linecardExplanation Peer linecard is non MSM/SSN-16
Recommended Action Informational no action required
Error Message IPS-5-FCIP_RA_CFG_MISMATCH: [chars]: Mismatch in FCIP Tape Read Acceleration capability with peerExplanation The FCIP Tape Read Acceleration capability does not match with peer's configuration
Recommended Action Fix the FCIP Tape Read Acceleration capability to be consistent with the peer
Error Message IPS-5-FCIP_SF_NOT_SUPPORTED: Special-Frame not supported for FCIP [chars]Explanation Spl-Frame not supported in this release
Recommended Action Informational no action required
Error Message IPS-5-FCIP_TA_CFG_MISMATCH: [chars]: Mismatch in FCIP Tape Acceleration configuration with peerExplanation The FCIP Tape Acceleration configuration does not match with peer's configuration
Recommended Action Fix the FCIP Tape Acceleration configuration to be consistent with the peer
Error Message IPS-5-FCIP_TA_ITL_MISMATCH: [chars]: Mismatch in FCIP Write/Tape Acceleration software capability with peerExplanation The FCIP Write/Tape Acceleration software capability does not match with peer's software capability
Recommended Action Fix the FCIP software to be consistent with the peer
Error Message IPS-5-FCIP_TSTAMP_CHK_FAILED: [chars]: Timestamp check failed on ingressing framesExplanation Timestamp between local and remote side exceeds the configured tolerance
Recommended Action No action is required.
Error Message IPS-5-FCIP_UNBIND_FAILED: UNBIND failed for [chars] due to [chars] for [chars]Explanation FCIP/ISCSI Interface UNBIND from Ethernet port failed
Recommended Action No action is required.
Error Message IPS-5-FCIP_WA_CFG_MISMATCH: [chars]: Mismatch in FCIP Write Acceleration configuration with peerExplanation The FCIP Write Acceleration configuration does not match with peer's configuration
Recommended Action Fix the FCIP Write Acceleration configuration to be consistent with the peer
Error Message IPS-5-FCIP_WA_XFER_RDY_ERR: [chars]: FCIP Write Acceleration received XFER-RDY after exhcange cleanup. Host [hex] Target [hex]Explanation FCIP Write/Tape Acceleration received XFER-RDY after exchange cleanup
Recommended Action No action is required.
Error Message IPS-5-FCIP_XRCE_CFG_MISMATCH: [chars]: Mismatch in FCIP XRC Emulator configuration with peerExplanation The FCIP XRC Emulator configuration does not match with peer's configuration
Recommended Action Fix the FCIP XRC Emulator configuration to be consistent with the peer
Error Message IPS-5-IPS_IPACL_LOG_MSG: [chars]Explanation Details of the packet dropped due to ACLs
Recommended Action No action is required.
Error Message IPS-5-IPS_MGR_FEATURE_ENABLE: ips:[dec] iscsi:[dec] fcip:[dec] iscsi-intf-vsan:[dec] ips-lc:[dec]Explanation IPS Manager feature enabled/disabled
Recommended Action No action is required.
Error Message IPS-5-IPS_TCP_PORT_IN_USE: Cannot bringup interface [chars], local port already in useExplanation FCIP and iSCSI interface are trying to use the same local port, please use different ports
Recommended Action No action is required.
Error Message IPS-5-ISCSI_BAD_DATA_DIGEST_CRC: iSCSI ingress data digest error from initiator [chars] alias [chars] S_ID [hex] to D_ID [hex]Explanation ISCSI Ingress Data Digest CRC failed
Recommended Action No action is required.
Error Message IPS-5-ISCSI_CONN_DOWN_BATCH: [chars]: [dec] iSCSI sessions failed in last [chars], reason: [chars]Explanation Number of iSCSI session down during the last time interval
Recommended Action No action is required.
Error Message IPS-5-ISCSI_CONN_DOWN: [chars]: iSCSI session down from initiator [chars] alias [chars] ip [chars] to target [chars], reason: [chars]Explanation ISCSI session goes down
Recommended Action No action is required.
Error Message IPS-5-ISCSI_CONN_UP: [chars]: iSCSI session up from initiator [chars] alias [chars] ip [chars] to target [chars]Explanation ISCSI session comes up and reaches Full-Feature phase
Recommended Action No action is required.
Error Message IPS-5-ISCSI_PORT_FAILOVER: [chars]: iSCSI initiator [chars] alias [chars] ip [chars] target [chars]. FC session failed over to port [chars]Explanation FC session for the iSCSI session failed over to newly active port
Recommended Action No action is required.
Error Message IPS-5-ISCSI_SB_GET_TGT: iSCSI SB get [dec] targets, initiator [chars] alias [chars] ip [chars]Explanation ISCSI FCNS query response
Recommended Action No action is required.
Error Message IPS-5-ISCSI_SESSION_CREATE_FAILURE: [chars]: iSCSI Session initiator [chars] target [chars] create failed. [chars]Explanation ISCSI Session Create failed
Recommended Action No action is required.
Error Message IPS-5-ISCSI_SESSION_CREATE_REDIRECT: [chars]: iSCSI Session initiator [chars] target [chars] redirected to [chars]/[chars]Explanation ISCSI Session Create redirected
Recommended Action No action is required.
Error Message IPS-5-ISCSI_SESSION_REDIRECT_TIMEOUT: iSCSI Session initiator [chars] to [chars] redirected to [chars] timeoutExplanation ISCSI Session Redirect timeout
Recommended Action No action is required.
Error Message IPS-5-ISLB_CFS_SESSION_CLEARED: CFS Session ClearedExplanation CFS Session Cleared by user
Recommended Action No action is required.
Error Message IPS-5-PORT_IPCFG_FAILED: Cannot configure IP address for interface [chars]Explanation Cannot configure IPS port IP address
Recommended Action No action is required.
Error Message IPS-5-SB_MGR_CORE_FAILED: Ethernet Processing core [chars] failed due to [chars]Explanation Ethernet Processing Core failed
Recommended Action No action is required.
Error Message IPS-5-SFRAME_ENTITY_ID_MISMATCH: [chars]: special frame profile ID mismatchExplanation Special frame received and destination profile ID does not match local profile ID
Recommended Action No action is required.
Error Message IPS-5-SFRAME_FABRIC_WWN_MISMATCH: [chars]: special frame fabric wwn mismatchExplanation Special frame received and source/destination fabric wwn does not match local destination/ source fabric wwn
Recommended Action No action is required.
Error Message IPS-5-SFRAME_IF_ADMIN_DOWN: [chars]: special frame received if downExplanation Special frame received and interface is admin down
Recommended Action No action is required.
Error Message IPS-5-SFRAME_IF_NOT_ENABLED: [chars]: special frame not enabledExplanation Special frame received and interface special frame configuration is disabled
Recommended Action No action is required.
Error Message IPS-5-SFRAME_INVALID_NONCE: [chars]: special frame response has invalid nonce for FCIPExplanation Special frame response has a different nonce than was originally sent in the special frame
Recommended Action No action is required.
Error Message IPS-5-SFRAME_NOT_RECV: [chars]: special frame was not received by passive-side FCIPExplanation Special frame was not received by the passive-side of the FCIP TCP tunnel within given time period
Recommended Action No action is required.
Error Message IPS-5-SFRAME_RESP_MISMATCH: [chars]: special frame response has byte mismatch for FCIPExplanation Special frame response has a mismiatch in one of the bytes from what was sent from the FCIP special frame sender
Recommended Action No action is required.
Error Message IPS-5-SFRAME_RESP_NOT_RECV: [chars]: special frame response was not received by active-side FCIPExplanation Special frame response was not received by the active-side of the FCIP TCP tunnel within given time period
Explanation FCIP-FTA Read Acceleration started
Recommended Action Informational no action required
Error Message IPS-6-FCIP_FTA_READ_ACCEL_STOPPED: Read Acceleration stopped for CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] due to [chars] after [dec] MB readsExplanation FCIP-FTA Read Acceleration stopped
Recommended Action Informational no action required
Error Message IPS-6-FCIP_FTA_WRITE_ACCEL_STARTED: Write Acceleration started for CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec]Explanation FCIP-FTA Write Acceleration started
Recommended Action Informational no action required
Error Message IPS-6-FCIP_FTA_WRITE_ACCEL_STOPPED: Write Acceleration stopped for CH FCID: [hex] CHI: [hex] CU FCID [hex] CUI: [hex] DA [hex] VSAN: [dec] due to [chars] after [dec] MB writesRecommended Action No action is required.
Error Message IPS-7-ISCSI_FCNS_QUERY_RESP: result [hex], [dec] targets, wait [dec], Init: [chars]Explanation ISCSI FCNS query response
Recommended Action No action is required.
Error Message IPS-7-ISCSI_NEW_FCNS_QUERY_REQ: return [hex], VSANs [chars], Init: [chars]Recommended Action No action is required.
Error Message IPS-7-ISCSI_NEW_FCNS_QUERY_RESP: result [hex], [dec] entries, [dec] targets, [dec] total targets Init: [chars]Explanation ISCSI FCNS query response
Recommended Action No action is required.
Error Message IPS-7-ISNS_SVR_ERR_RESPONSE: iSNS server returned following error code on iSNS request for interface [chars] : [dec]Explanation ISNS server returned an error for register/deregister request. For select error codes iSNS client would retry and re-register all target nodes corresponding to the interface
Explanation The IP Configuration Manager failed to allocate a block of dynamic memory.
Explanation Writing to a file failed probably due to no space.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message IPV6-3-INIT_FAILED: Initialization failed. Component [chars]Explanation The service failed to start. The failure occurred while initializing the component [chars].
Recommended Action Show processes to check the status of the other processes, debug the specified component.
Explanation Duplicate address detection for IP address failed.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message IPV6-6-CONFIG_EVENT: IP Configuration Msg: [chars]Explanation Configuration message that needs to be logged.
Recommended Action No action is required.
Error Message IPV6-6-INTERFACE_DELETED: The interface [chars] has been deletedExplanation The specified interface has been deleted. The service will delete all the configuration on that interface.
Recommended Action No action is required.
Error Message IPV6-6-INTERFACE_EVENT: IP address [chars] [chars] on interface [chars]Explanation The IP address [chars] has been successfully [chars] on the interface [chars].
Recommended Action No action is required.
Error Message IPV6-6-ROUTE_NOT_ACTIVE: The [chars] is not activeExplanation The specified route is successfully configured but currently is not active.
Recommended Action Check that the route is correct and the outgoing interface is operationally up.
Error Message IPV6-6-STARTING: IP configuration Manager startedExplanation The IP Configuration Manager service has successfully started.
Explanation The IP Configuration Manager failed to allocate a block of dynamic memory.
Explanation Writing to a file failed probably due to no space.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message IP-3-INIT_FAILED: Initialization failed. Component [chars]Explanation The service failed to start. The failure occurred while initializing the component [chars].
Recommended Action Show processes to check the status of the other processes, debug the specified component.
Explanation Duplicate address detected for IP address.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Explanation Configuration message that needs to be logged.
Recommended Action No action is required.
Error Message IP-6-INTERFACE_DELETED: The interface [chars] has been deletedExplanation The specified interface has been deleted. The service will delete all the configuration on that interface.
Recommended Action No action is required.
Error Message IP-6-INTERFACE_EVENT: IP address [chars] [chars] on interface [chars]Explanation The IP address [chars] has been successfully [chars] on the interface [chars].
Recommended Action No action is required.
Error Message IP-6-ROUTE_NOT_ACTIVE: The [chars] is not activeExplanation The specified route is successfully configured but currently is not active.
Recommended Action Check that the route is correct and the outgoing interface is operationally up.
Error Message IP-6-STARTING: IP configuration Manager startedExplanation The IP Configuration Manager service has successfully started.
Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-0-MSM_EMERG: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-0-NSP_EMERG: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-0-SSM_EMERG: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-0-SSN_EMERG: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-1-MSM_ALERT: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-1-NSP_ALERT: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-1-SSM_ALERT: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-1-SSN_ALERT: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-2-MSM_CRIT: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-2-NSP_CRIT: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-2-SSM_CRIT: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-2-SSN_CRIT: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-3-MSM_ERROR: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-3-NSP_ERROR: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-3-SSM_ERROR: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-3-SSN_ERROR: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-4-MSM_WARN: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-4-NSP_WARN: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-4-SSM_WARN: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-4-SSN_WARN: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-5-MSM_NOTICE: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-5-NSP_NOTICE: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-5-SSM_NOTICE: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-5-SSN_NOTICE: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-6-MSM_INFO: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-6-NSP_INFO: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-6-SSM_INFO: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-6-SSN_INFO: [chars]Explanation Isapi-invista software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-7-MSM_DEBUG: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-7-NSP_DEBUG: [chars]Explanation Isapi-nsp software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-7-SSM_DEBUG: [chars]Explanation Isapi software messages
Recommended Action No action is required.
Error Message ISAPI-SLOT#-7-SSN_DEBUG: [chars]Explanation ISNS CFS operation failed
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message ISNS-2-ISNS_INIT: iSNS initialization of [chars] [chars]Explanation ISNS initialization failed
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation This can happen if failure happens during building, distributing or committing the virtual dynamic pfcid table
Recommended Action Please 1. check the fabric connection or 2. check current virtual user-configured pfcid entries and internally assigned virtual fcid entries for possible conflict
Error Message IVR-2-AUTOLEARN_FEATURE_NOT_SUPPORT: some switches:[chars] don't support autolearnExplanation This can happen if some switches doesn't support the virtual pfcid autolearn feature
Recommended Action Please upgrade the unsupported switches
Error Message IVR-2-CFS_PEER_LOST_WITHIN_SESSION: CFS peer with switch wwn [chars] was lost in the middle of an active CFS session. Abort the CFS session and re-enter the configuration changesExplanation Due to port flaps, link outages, switch restart etc. a CFS peer switch of IVR was lost. The current configuration changes would not be applied to this peer until the peer merges with this switch. The CFS merge may fail if the configuration at the lost peer conflicts with the changes made in this session. Also, IVR auto topology could be out of sync. with this peer. It is recommended that the user abort this CFS session using ivr abort command and then re-enter the configuration changes.
Recommended Action No action is required.
Error Message IVR-2-DEVICE_FCID_REWRITE_FAILURE: Failure while programming FCID rewrite entries for pWWN [chars] on incoming VSAN [dec]. Device may not be able to communicate with its peer devices, failure reason code: [hex]Explanation Failed to program FCID rewrite entries probably because the hardware ran out of FCID rewrite entries. This can happen if there are too many devices in Inter-VSAN zone or too many local VSANs in VSAN topology
Recommended Action Reduce the number of devices involved in IVR in the active IVR zoneset. Also, reduce the number of redundant transit VSANs, if any
Error Message IVR-2-DEVICE_STATE_INCOMPATIBLE_WITH_NAT_MODE: State for device with port WWN [chars] could not be restored because it was incompatible with the current NAT mode([dec]). This probably happened because NAT mode was modified without completely deactivating the active IVR zonesetExplanation This probably happened because NAT mode was modified without completely deactivating the active IVR zoneset
Recommended Action The switch needs to be rebooted
Error Message IVR-2-DEVICE_VSAN_REWRITE_FAILURE: Failure while programming VSAN rewrite entries for pWWN [chars] on incoming VSAN [dec]. Device may not be able to communicate with its peer devicesExplanation Failed to program VSAN rewrite entries probably because the hardware ran out of VSAN rewrite entries. This can happen if there are too many devices in Inter-VSAN zone or too many local VSANs in VSAN topology
Recommended Action Reduce the number of domains involved in IVR by moving the members of active IVR zoneset to fewer switches. Also, reduce the number of redundant transit VSANs, if any
Error Message IVR-2-INTEROP_MODE_2_OR_3_BF_FAILED: [chars] VSAN [dec] Virtual Domain [chars]Explanation Build Fabric (BF) failed in VSAN [dec]. The BF was initiated in order to remove an unused virtual domain [dec] from the fcdomain list in that VSAN. The virtual domain still remains in the fcdomain list and hence it would not be available in that VSAN for assignment.
Recommended Action Perform a manual build fabric using fcdomain's interface if you would like to remove the unused virtual domain(s) from the fcdomain list.
Error Message IVR-2-INTEROP_MODE_2_OR_3_RDI_FAILED: VSAN [dec], requested domain [chars], received domain [chars] sWWN [chars]. Return Code [chars]Explanation Request Domain Identifier (RDI) command to allocate virtual domain [dec] failed in VSAN [dec]. Received another domain [chars] instead. IVR-members connected to third-party switch may not participate in IVR communications. It is likely that the domain requested in the RDI command is already in use.
Recommended Action Reassign the domains so that the domain requested via RDI does not overlap with any existing domain in that VSAN.
Error Message IVR-2-IVR_DISABLE_FAILED: Inter-VSAN Routing disable failed for reason: [chars]Explanation Inter-VSAN Routing disable failed for reason: [chars]. Cleanup might not have completed
Recommended Action Deactivate ivr zoneset and disable ivr again. If that fails, then the ivr process would terminate itself in 5 minutes
Error Message IVR-2-IVZS_ACTIVATION_FAILED_RETRYING: Inter-VSAN zoneset activation failed in VSAN [dec] : [chars]. retrying after [dec] secondsExplanation Inter-VSAN zoneset activation failed in VSAN [dec] : [chars]. This could be an intermittent regular zoneset activation error. The activation will be retried in [dec] seconds.
Recommended Action No action is required.
Error Message IVR-2-NO_LICENSE_SHUTDOWN: Inter-VSAN Routing is shutting down.Explanation License required for continued IVR operation is not available. Hence IVR is shutting down
Recommended Action Install appropriate license for IVR services and then enable IVR again.
Error Message IVR-2-NO_LICENSE_WARNING: Inter-VSAN Routing would shutdown in [dec] seconds.Explanation License required for continued IVR operation is not available. Unless the required license is installed IVR would shutdown in [dec] seconds. IVR configurations would be lost.
Recommended Action Install appropriate license for IVR services to continute to operate uninterrupted within [dec] seconds
Error Message IVR-2-PERSISTENT_VIRTUAL_FCID_CONFLICT_WITH_AUTOLEARN: Persistent virtual fcid and dynamic pfcid entriesExplanation This can happen if conflict happens during persistent virtual domain, or virtual fcid entry configuration.
Recommended Action Please assign a non-conflict persistent virtual domain or fcid entry with current dynamic entries
Error Message IVR-2-PERSISTENT_VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the configured persistent virtual domain/fcid could not be assignedExplanation This can happen if the virtual domain/fcid configured by the user is - a) Already in use (either by IVR or a real switch) b) Not allowed due to interop mode or allowed domain list
Recommended Action Please make sure that the configured virtual domain/fcid is allowed and available for use
Error Message IVR-2-VIRTUAL_DOMAIN_CONFLICT: In VSAN [dec] virtual domain [dec] from native VSAN [dec] conflicts with native VSAN [dec] for the same virtual domainExplanation Currently advertised virtual domain [dec] in VSAN [dec] is native to VSAN [dec]. This switch has learned of a device that is member of active IVR zone and has the same domain ID, but belongs to a different native VSAN. This device would not be advertised in that VSAN until the domain conflict is resolved.
Recommended Action No action is required.
Error Message IVR-2-VIRTUAL_FCID_UNAVAILABLE: to vsan [dec] because the internally generated FCID conflicts with fcid assigned to WWN [chars]. Please configure fcid for WWN [chars] tooExplanation This can happen if the virtual domain/fcid internally configured is already in use by another active device
Recommended Action Please assign a different persistent virtual fcid by CLI command
Explanation Could be caused by ivr NAT is not enable
Recommended Action No action is required.
Error Message IVR-3-AAM_MODE_DEREGISTERED_FAILED: Abstract ACL Manager (AAM) mode deregister failed. Error code is [chars].Explanation Abstract ACL Manager (AAM) mode deregister failed
Recommended Action No action is required.
Error Message IVR-3-AAM_MODE_REGISTERED_FAILED: Abstract ACL Manager (AAM) register failed. Error code is [chars].Explanation Abstract ACL Manager (AAM) register failed
Recommended Action No action is required.
Error Message IVR-3-ACL_ERROR: ACL API, [chars], failed with error [chars]Explanation IVR invoked ACL API and received the error code. [chars] describes the API and [chars] specifies the error.
Recommended Action No action is required.
Error Message IVR-3-ACL_PERMIT_ENTRY_ERROR: ACL permit entry update on interface [chars] failed for reason: [chars]Explanation ACL could not program permit entries for IVR traffic. [chars] describes the interface named and [chars] describes the system error message from ACL. IVR traffic coming from the interface may be dropped.
Recommended Action If the problem persists, please contact TAC, or your reseller for support.
Error Message IVR-3-ACL_PLOGI_ENTRY_ERROR: PLOGI capture entry update in slot [dec] failed for reason: [chars]Explanation ACL could not program IVR PLOGI could not be programmed. slot[dec] describes the line card slot number and [chars] describes the system error message. PLOGI and its response may be dropped because ivr process cannot capture those frames.
Recommended Action No action is required.
Error Message IVR-3-AFID_CONFLICT: [chars]Explanation AFID configuration is different at different ivr-enabled switches in the same VSAN. Change AFID configuration (auto mode) or vsan topology configuration (user mode) to make it consistent
Recommended Action No action is required.
Error Message IVR-3-CFS_INVALID_PAYLOAD_RECEIVED: Inter-VSAN process received invalid payload from CFSExplanation Inter-VSAN process received invalid payload from CFS.
Recommended Action No action is required.
Error Message IVR-3-CLEAR_FAILED: [chars]Explanation An error occurred while clearing the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-COMMIT_FAILED: [chars]Explanation An error occurred while committing configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-COMMIT_PARTIALLY_FAILED: [chars]Explanation An error occurred while committing configuration. Configuration could not be committed on some switches. The reason for the failure : [chars]. Configuration can be inconsistent in the fabric.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-COMMIT_REJECTED: [chars]Explanation Commit request received from remote switch is rejected. The reason for the failure: [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-DDAS_LOCK_TIMER_EXPIRED: IVR database lock is released, as device-alias commit/abort notification is not received in the expected time frame.Explanation When device-alias sends the validation request, IVR database is locked and a timer is started. For any reason, if device-alias commit/abort notification is not received within the expected time frame, the lock timer gets expired and the lock is released. If device-alias commmit notification is received after the lock is released, the changes are not applied and this could cause inconsistency between IVR and device-alias.
Recommended Action No action is required.
Error Message IVR-3-DEVICE_NOT_PREENT_IN_FB_DB_FICON: Device with port WWN [chars] could not be exported to VSANs [chars] because its native switch is not present in the current active fabric binding database of those VSANs.Explanation This happens if ficon is enabled on VSANs [chars] and native switch of device with port WWN [chars] is not present in the current active fabric binding database of those VSANs. This is a requirement for ficon compliance.
Recommended Action No action is required.
Error Message IVR-3-DEVICE_ON_WRONG_NATIVE_AFID_VSAN: Device with port WWN [chars] (FCID:[chars], native VSAN [dec] native AFID [dec]) may not be exported to other VSANs (for Inter-VSAN zoning) because it has come online in VSAN [dec] AFID [dec]Explanation Device has come online on a AFID/VSAN different from the configured native AFID/VSAN
Recommended Action No action is required.
Error Message IVR-3-DEVICE_ON_WRONG_NATIVE_VSAN: Device with port WWN [chars] (FCID:[chars], native VSAN [dec]) may not be exported to other VSANs (for Inter-VSAN zoning) because domain [hex] exists in VSAN [dec]Explanation Device has come online on a VSAN different from the configured native VSAN or the device does not satisfy unique domain criteria.
Recommended Action No action is required.
Error Message IVR-3-DM_ERROR: Domain Manager API, [chars], failed with error [hex]Explanation IVR invoked DM API and received the error code. [chars] describes the API and 0x[hex] specifies the error.
Recommended Action No action is required.
Error Message IVR-3-DOMAIN_DISALLOWED_IN_INTEROP: Device with port WWN [chars] and FCID [chars] may not be able to participate in Inter-VSAN zone since domain [dec] is disallowed in the interop mode for VSAN [dec]Explanation VSAN interop modes place restrictions on what domain ranges are allowed. This domain is out of the range allowed for this interop mode. See the Cisco MDS 9000 Family Configuration Guide for details on the domain range limitations.
Recommended Action Change the domain of the switch to which this IVR zone member is connected to so that it is within the allowed domain list for the interop mode. The domain identifier can be statically assigned using fcdomain interface. You can also configure a range of domains allowed in a VSAN using the fcdomain's 'allowed-domains' interface.
Error Message IVR-3-DOMAIN_UNAVAILABLE: Device with port WWN [chars] and FCID [chars] may not be able to participate in Inter-VSAN zone since domain [dec] is already assigned in VSAN [dec]Explanation Device with port WWN [chars] and FCID [dec] may not be able to participate in Inter-VSAN zone since domain [dec] is already assigned in VSAN [dec].
Recommended Action No action is required.
Error Message IVR-3-FC2_ERROR: FC2 API [chars] failed with error [hex] for [chars]Explanation IVR invoked FC2 API for [chars] socket and received the error code. [chars] describes the API and 0x[hex] specifies the error.
Recommended Action No action is required.
Error Message IVR-3-FCID_NAT_MODE_CANNOT_CHANGE: IVR NAT mode cannot be changed. Might cause the fabric NAT mode inconsistencyExplanation Could be caused by active zoneset, pending activation /deactivation or non-empty device list
Recommended Action No action is required.
Error Message IVR-3-FCID_REWRITE_REQUEST_TO_ACL_FAILED: fcid rewrite [chars] request vsan [dec] did [chars] sid [chars] failed:[chars]([hex]).Explanation This happens when either after IVR retried the request few times or ACL experienced error while processing the request.
Recommended Action No action is required.
Error Message IVR-3-INTERNAL_ERROR: Internal error: [chars]Explanation IVR process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message IVR-3-INVALID_ZONE_MEMBER_PROP_INTEROP_MODE_2_3: unsupported member/zone properties in interop mode 2 or 3 [chars]Explanation Inter-VSAN member properties incompatible with interop mode vsan
Recommended Action No action is required.
Error Message IVR-3-IVR_NAT_OFF_IS_SAB: Fcid-nat must be enabled before IVR zoneset activation for Sabre platform.Explanation Fcid-nat must be enabled before IVR zoneset activation for Sabre platform.
Recommended Action No action is required.
Error Message IVR-3-IVZ_ACTIVATION_FAILED_VSAN: Inter-VSAN zoneset [chars] activation failed in VSAN [dec]Explanation Inter-VSAN zoneset activation failed failed in VSAN.
Recommended Action No action is required.
Error Message IVR-3-IVZ_ACTIVATION_FAILED: Inter-VSAN zoneset [chars] activation failedExplanation Inter-VSAN zoneset activation failed.
Recommended Action No action is required.
Error Message IVR-3-IVZ_DEACTIVATION_FAILED_VSAN: Inter-VSAN zoneset [chars] deactivation failed in VSAN [dec]Explanation Inter-VSAN zoneset deactivation failed in VSAN.
Recommended Action No action is required.
Error Message IVR-3-IVZ_DEACTIVATION_FAILED: Inter-VSAN zoneset [chars] deactivation failedExplanation Inter-VSAN zoneset deactivation failed.
Recommended Action No action is required.
Error Message IVR-3-LOCK_FAILED: [chars]Explanation An error occurred while acquiring the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-MERGE_ACTIVATION_FAILED: [chars]Explanation An error occurred while activating merged configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-MERGE_FAILED: reason is [chars]Explanation An error occurred while merging configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-MTS_ERROR: MTS message transmission failed with error [dec]Explanation IVR process unsuccessfully tried to send a MTS message. MTS error number is specified in [dec].
Recommended Action No action is required.
Error Message IVR-3-NS_ERROR: FCNS API, [chars], failed with error [hex]Explanation IVR invoked FCNS API and received the error code. [chars] describes the API and 0x[hex] specifies the error.
Recommended Action No action is required.
Error Message IVR-3-PSS_CFG_RESTORE_ERROR: Configuration restoration for [chars] failed with error [hex]Explanation IVR read the saved configuration and encountered an error while rebuilding the runtime configuration. [chars] describes the configuration which the process tried to restore and 0x[hex] is the system err code.
Recommended Action No action is required.
Error Message IVR-3-PSS_ERROR: PSS operation [chars] returned error: [hex]Explanation [chars] specifies the context where the failure occurred and 0x[hex] specifies the error.
Recommended Action No action is required.
Error Message IVR-3-PSS_RTDB_RESTORE_ERROR: Runtime database restoration for [chars] failed with error [hex]Explanation IVR read the saved runtime database and encountered an error while rebuilding the runtime database. [chars] describes the runtime database which the process tried to restore and 0x[hex] is the system error code.
Recommended Action No action is required.
Error Message IVR-3-QOS_IOD_UNDROP_REQUEST_TO_ACL_FAILED: qos iod undrop request vsan [dec] did [chars] failed:[chars].Explanation This happens when either after IVR retried the request few times or ACL experienced error while processing the request.
Recommended Action No action is required.
Error Message IVR-3-RIB_ERROR: RIB API, [chars], failed with error [hex]Explanation IVR invoked RIB API and received the error code. [chars] describes the API and 0x[hex] specifies the error.
Recommended Action No action is required.
Error Message IVR-3-ROUTE_REQUEST_TO_ACL_FAILED: route [chars] request vsan [dec] domain [dec] failed:[chars].Explanation This happens when either after IVR retried the request few times or ACL experienced error while processing the request.
Recommended Action No action is required.
Error Message IVR-3-TOPOLOGY_COMPUTATION_FAILED: Inter-VSAN Topology computation has failed due to: [chars]Explanation Inter-VSAN Topology has failed due to [chars]. Possible reasons are (a) Number of AFID/VSAN combination is more than te maximum supported value of 128, or (b) Number of ivr-enabled switches is more than the maximum supported value of 128
Recommended Action No action is required.
Error Message IVR-3-UNEXPECTED_MTS_MSG: Unexpected MTS message, opcode [dec], is receivedExplanation IVR process received unexpected MTS event. MTS opcode is specified in [dec].
Recommended Action No action is required.
Error Message IVR-3-UNLOCK_FAILED: [chars]Explanation An error occurred while releasing the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-VSAN_SEGMENTED: [chars]Explanation VSAN is segmented. VSAN is removed from the topology graph and hence no Inter-VSAN traffic can flow through this VSAN.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message IVR-3-ZS_POLICY_IS_DENY_NO_ACTIVE_ZS: Default zone behavior policy is deny on VSAN [dec] and there is no active zonesetExplanation Default zone behavior is deny and there is no active zoneset. Inter-VSAN zone members may not be able communicate in this VSAN.
Recommended Action No action is required.
Error Message IVR-3-ZS_POLICY_IS_PERMIT_NO_FORCE: Default zone behavior policy is permit on VSAN [dec] and the force option is offExplanation Default zone behavior is permit and the force option is off. Inter-VSAN zoneset activation on this VSAN has failed.
Recommended Action No action is required.
Error Message IVR-3-ZS_POLICY_IS_PERMIT_ZS_DEACTIVATED: Default zone behavior policy is permit on VSAN [dec] and regular zoneset deactivatedExplanation Default zone behavior is permit and regular zoneset is deactivated. Inter-VSAN zone members may not be able to communicate.
Explanation Received auto topology update is discarded due to conflicts
Recommended Action No action is required.
Error Message IVR-4-FCID_REWRITE_REQUEST_TO_ACL_FAILED_AND_RETRYING: fcid rewrite [chars] request vsan [dec] did [chars] sid [chars] failed:[chars]([hex]). Retrying the request again.Explanation This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.
Recommended Action No action is required.
Error Message IVR-4-IVR_REMOVED_PENDING_CFG: IVR was removed while there were still pending IVR configurations. Forceful cleanup was triggered and the pending configurations were not saved.Explanation IVR was removed from an N7K switch via VDC delete/reload, which triggered a forceful cleanup. The pending IVR configurations were not saved.
Recommended Action No action is required.
Error Message IVR-4-PERSISTENT_VIRTUAL_DOMAIN_MERGE_CONFLICT: [chars]Explanation Merge failed due to conflict in the persistent virtual domain configuration
Recommended Action No action is required.
Error Message IVR-4-PERSISTENT_VIRTUAL_FCID_MERGE_CONFLICT: [chars]Explanation Merge failed due to conflict in the persistent virtual fcid configuration
Recommended Action No action is required.
Error Message IVR-4-QOS_IOD_UNDROP_REQUEST_TO_ACL_FAILED_AND_RETRYING: qos iod undrop request vsan [dec] did [chars] failed:[chars]. Retrying the request again.Explanation This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.
Recommended Action No action is required.
Error Message IVR-4-ROUTE_REQUEST_TO_ACL_FAILED_AND_RETRYING: route [chars] request vsan [dec] domain [dec] failed:[chars]. Retrying the request again.Explanation This happens when either any of the linecards being upgraded or ACL experienced error while processing the request.
Recommended Action No action is required.
Error Message IVR-4-UNKNOWN_NATIVE_VSAN: Unknown native VSAN for the virtual domain [dec] in VSAN [dec] local native VSAN for the same virtual domain is [dec]Explanation Could not determine native VSAN of the currently advertised virtual domain [dec] in VSAN [dec]. This switch has learned of a device that is member of active IVR zone has the same domain ID, and belongs to native VSAN [dec]. This device would not be advertised in that VSAN until the native VSAN information is resolved.
Explanation Abstract ACL Manager (AAM) mode has been deregistered
Recommended Action No action is required.
Error Message IVR-5-AAM_MODE_REGISTERED: Abstract ACL Manager (AAM) mode has been registeredExplanation Abstract ACL Manager (AAM) mode has been registered
Recommended Action No action is required.
Error Message IVR-5-FCID_NAT_MODE_ACTIVATED: FCID network address translation (NAT) mode has been activatedExplanation FCID network address translation (NAT) mode has been activated
Recommended Action No action is required.
Error Message IVR-5-FCID_NAT_MODE_DEACTIVATED: FCID network address translation (NAT) mode has been deactivatedExplanation FCID network address translation (NAT) mode has been deactivated
Recommended Action No action is required.
Error Message IVR-5-IVR_ASSERTION_FAILED: Unexpected assertion failure in File [chars] at Line [dec]Explanation An assertion failed in IVR code
Recommended Action No action is required.
Error Message IVR-5-IVZS_ACTIVATION_RETRYING: Inter-VSAN zoneset activation did not go through because of [chars], retrying in VSAN [dec] after [dec] secondsExplanation Inter-VSAN zoneset activation failed because of [chars] in VSAN [dec]. This could be an intermittent regular zoneset activation error. The activation will be retried in [dec] seconds.
Recommended Action No action is required.
Error Message IVR-5-IVZS_WAITING_FOR_LOWEST_SWWN: Waiting for lowest switch WWN Inter-VSAN enabled switch in VSAN [dec]Explanation Only lowest switch WWN Inter-VSAN enabled switch adds the Inter-VSAN zones to the regular active zoneset in a VSAN. This local switch is not the lowest sWWN switch in VSAN [dec]
Recommended Action No action is required.
Error Message IVR-5-IVZ_ACTIVATED_VSAN: Inter-VSAN zoneset [chars] activated in VSAN [dec]Explanation Inter-VSAN zoneset activated in VSAN[dec].
Recommended Action No action is required.
Error Message IVR-5-IVZ_ACTIVATED: Inter-VSAN zoneset [chars] activatedExplanation Inter-VSAN zoneset activated[dec].
Recommended Action No action is required.
Error Message IVR-5-IVZ_CLEANUP_DONE_BY_TIMER: Inter-VSAN clean-up is not done after waiting for 5 minutesExplanation Inter-VSAN related configuration might not be cleaned up before the ivr process is terminated
Recommended Action If the problem persists, you may have to reboot your switch to clean up the old IVR configuration
Error Message IVR-5-IVZ_CLEANUP_DONE: Inter-VSAN clean-up is doneExplanation Inter-VSAN related configuration is cleaned up before exiting.
Recommended Action No action is required.
Error Message IVR-5-IVZ_DEACTIVATED_VSAN: Inter-VSAN zoneset [chars] deactivated in VSAN [dec]Explanation Inter-VSAN zoneset deactivated in VSAN[dec].
Recommended Action No action is required.
Error Message IVR-5-IVZ_DEACTIVATED: Inter-VSAN zoneset [chars] deactivatedExplanation Inter-VSAN zoneset deactivated[dec].
Recommended Action No action is required.
Error Message IVR-5-IVZ_PARTIALLY_ACTIVATED: Inter-VSAN zoneset [chars] partially activatedExplanation Inter-VSAN zoneset activated[dec].
Recommended Action Check if it is successful in all VSANs by doing show IVR zoneset status.
Error Message IVR-5-IVZ_PARTIALLY_DEACTIVATED: Inter-VSAN zoneset [chars] partially deactivatedExplanation Inter-VSAN zoneset deactivated[dec].
Recommended Action Check if it is successful in all VSANs by doing show IVR zoneset status.
Error Message IVR-5-LICENSE_CHECKIN_FAILED: Failed to checkin [chars] license: Err=[chars]Explanation Failed to checkin [chars] license
Recommended Action No action is required.
Error Message IVR-5-SERVICE_GROUP_ACTIVATED: Inter-VSAN Service Group has been activatedExplanation Inter-VSAN Service Group has been activated.
Recommended Action No action is required.
Error Message IVR-5-SERVICE_GROUP_DEACTIVATED: Inter-VSAN Service Group has been deactivatedExplanation Inter-VSAN Service Group has been deactivated.
Recommended Action No action is required.
Error Message IVR-5-VSAN_NO_LONGER_SEGMENTED: [chars]Explanation VSAN is no longer segmented. VSAN is added back to the topology graph and hence Inter-VSAN traffic can now flow through this VSAN.
Recommended Action No action is required.
Error Message IVR-5-VSAN_TOPOLOGY_ACTIVATED: Inter-VSAN Topology has been activatedExplanation DRAV FSM has unconditionally released a domain due to conflict after a fabric merge. The details are in [chars]
Recommended Action No action is required.
Error Message IVR-6-DRAV_CRITICAL_RETRY_EXCEED: [chars]Explanation DRAV FSM frames are attempted to be resent. The details are in [chars]
Recommended Action No action is required.
Error Message IVR-6-DRAV_DOMAIN_ALLOC: Virtual domain [dec] for Native AFID: [dec] Native VSAN [dec]Explanation A virtual domain indicated by [dec] has been reserved for a device with native AFID [dec] and native VSAN [dec]
Recommended Action No action is required.
Error Message IVR-6-DRAV_DOMAIN_RELEASE: Virtual domain [dec] for Native AFID: [dec] Native VSAN [dec]Explanation A virtual domain indicated by [dec] has been released used by devices with native AFID [dec] and native VSAN [dec]
Recommended Action No action is required.
Error Message IVR-6-DRAV_TOPO_UPDATE: [chars]Explanation DRAV FSM Topology has been updated as indicated by [chars]
Recommended Action No action is required.
Error Message IVR-6-LICENSE_VALID: A valid license for Inter-VSAN Routing has been obtainedExplanation A valid license for Inter-VSAN Routing has been obtained
Explanation CFS request is received. The WWN of the switch originated this request and the rr-token of the request are provided in the syslog message.
Recommended Action No action is required.
Error Message IVR-7-CFS_RESP_SENT: [chars]Explanation CFS response is sent. The rr-token of the corresponding request and the status are provided in the syslog message
Explanation L2FMC failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'
Recommended Action No action is required.
Error Message L2FMC-SLOT#-0-L2FMC_TIMER_INIT_FAILED: Timer subsystem initialization failed!Explanation L2FMC failed to initialize timer library. This is a fatal error.
Explanation Memory allocation failed. This is a critical failure
Recommended Action No action is required.
Error Message L2FMC-SLOT#-2-L2FMC_VLAN_NOT_FOUND: VLAN [dec] not found in L2FMC database!Explanation L2FMC failed to find VLAN [dec] in its database. L2 MAC learning & aging on VLAN [dec] may be affected.
Explanation Kernel messages provide additional information about the applications and help debug application errors.
Explanation L2FMC failed to configure global default age to [dec] seconds.
Recommended Action No action is required.
Error Message L2FMC-SLOT#-5-L2FMC_VLAN_AGE_CONFIG_FAIL: VLAN Age configuration to [dec] seconds failed!Explanation L2FMC failed to configure age for VLAN [dec] to [dec] seconds.
Explanation L2FMC has successfully configured global default age to [dec] seconds.
Recommended Action No action is required.
Error Message L2FMC-SLOT#-6-L2FMC_INITIALIZED: Internal state created [chars]Explanation L2FMC has created its internal state stateless/stateful [chars].
Recommended Action No action is required.
Error Message L2FMC-SLOT#-6-L2FMC_VDC_CREATED: VDC [dec] createdExplanation Request to create VDC [dec] in L2FMC was successful.
Recommended Action No action is required.
Error Message L2FMC-SLOT#-6-L2FMC_VDC_REMOVED: VDC [dec] RemovedExplanation L2FMC has successfully removed VDC [dec] from its databases.
Recommended Action No action is required.
Error Message L2FMC-SLOT#-6-L2FMC_VDC_VLAN_CREATED: VLAN [dec] createdExplanation L2FMC has added VLAN [dec].
Recommended Action No action is required.
Error Message L2FMC-SLOT#-6-L2FMC_VDC_VLAN_REMOVED: VLAN [dec] removed from VDC [dec]Explanation L2FMC has successfully removed VLAN [dec] from VDC [dec].
Recommended Action No action is required.
Error Message L2FMC-SLOT#-6-L2FMC_VLAN_AGE_CONFIGURED: Age configured for VLAN [dec] to [dec] seconds.Explanation L2FMC has successfully configured age for VLAN [dec] to [dec] seconds.
Explanation Failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'
Recommended Action No action is required.
Error Message L2FM-0-L2FM_VDC_GWMAC_GET_FAILED: Failed to get gwmac for VDCExplanation Failed to get gwmac for VDC.
Recommended Action No action is required.
Error Message L2FM-0-L2FM_WRITE_TO_PSS_FAILED_IN_PREVIOUS_INCARNATION: PSS Write Failed in pervious incarnation. Stateful restart not possibleExplanation PSS Write Failed in pervious incarnation. Stateful restart not possible
Explanation No action is required.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message L2FM-1-L2FM_LINE_FULL_CONDITION_STRING: Unable to insert the MAC as hardware lines are fullExplanation No action is required.
Error Message L2FM-1-L2FM_ORIB_SENDS_INCORRECT_IFIDX: Incorrect ifidx received from Orib. Please check mac [chars] vlan [dec]Explanation L2fm has received a mac insert/delete from Orib with incorrect ifidx. Please check otv mac entries
Recommended Action No action is required.
Error Message L2FM-1-L2FM_OWNER_NOT_FOUND: Error : fe owner not found for mac entry [chars] in age notif sent from slot = [dec], fe = [dec]Explanation L2fm has received an age notification from the linecard but does not have the mac owner in its database
Recommended Action No action is required.
Error Message L2FM-1-L2FM_SDB_NOT_FLUSHED: Error : [dec] mac entries have not flushed from l2fm sdbExplanation Due to an internal error l2fm has not written mac entries to its sdb
Recommended Action No action is required.
Error Message L2FM-1-L2FM_SMAC_DUP_FOUND: Duplicate static mac found in secondary vlan. P-VLAN:[dec] S-VLAN:[dec] MAC:[chars]Explanation Duplicate static mac found in secondary vlan. P-VLAN:[dec] S-VLAN:[dec] MAC:[chars]
Recommended Action No action is required.
Error Message L2FM-1-L2FM_WRITE_TO_PSS_FAILED: Failed to write to PSS err [chars]Explanation Failed to set age time [dec] for vlan [dec].
Recommended Action No action is required.
Error Message L2FM-2-L2FM_GLBL_AGING_TIME_SET_FAILED: Failed to set global age time [dec]Explanation Failed to set global age time [dec]
Recommended Action No action is required.
Error Message L2FM-2-L2FM_SMAC_INS_FAILED: Failed to insert static mac for VLAN:[dec] MAC:[chars] IfIndex:[hex] Slot:[dec]Explanation No action is required.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message L2FM-2-L2FM_UPDATE_LOST_HINTS: mac [hex]:[hex]:[hex]:[hex]:[hex]:[hex] updated by slot [dec] fe_index [dec], from [hex] to [hex], with [hex] new hints and loosing %08 old_hints. stack trace: [chars]Explanation An update from MTM looks inconsistent with the previous state
Explanation Mac [string] has moved from [string] to [string]
Explanation Failed to insert dynamic macs fail_cnt:[dec] for Slot:[Slot]
Recommended Action No action is required.
Error Message L2FM-6-L2FM_MTS_SEND_FAILED: Failed to send MTS message errno [hex] opcode [dec]Explanation No action is required.
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Explanation L2MCAST failed to initialize CLI infrastructure\sbackendlibrary.Thisisafatalerror.'
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-0-L2MCAST_TIMER_INIT_FAILED: Timer subsystem initialization failed!Explanation L2MCAST failed to initialize timer library. This is a fatal error.
Explanation L2MCAST failed to find VLAN [dec] in its database. L2 MAC learning & aging on VLAN [dec] may be affected.
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-2-L2MCAST: Memory allocation failed. [chars]Explanation Memory allocation failed. This is a critical failure
Explanation L2MCAST failed to insert bd, g, s entry in hardware. Igmp snooping may not be effective on vlan for that group and source
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-6-L2MCAST_INITIALIZED: Internal state created [chars]Explanation L2MCAST has created its internal state stateless/stateful [chars].
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-6-L2MCAST_VDC_CREATED: VDC [dec] createdExplanation Request to create VDC [dec] in L2MCAST was successful.
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-6-L2MCAST_VDC_REMOVED: VDC [dec] RemovedExplanation L2MCAST has successfully removed VDC [dec] from its databases.
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-6-L2MCAST_VDC_VLAN_CREATED: VLAN [dec] createdExplanation L2MCAST has added VLAN [dec].
Recommended Action No action is required.
Error Message L2MCAST-SLOT#-6-L2MCAST_VDC_VLAN_REMOVED: VLAN [dec] removed from VDC [dec]Explanation L2MCAST has successfully removed VLAN [dec] from VDC [dec].
Recommended Action No action is required.
Error Message LACP-3-LACP_MEM_PC_MISCFG: LACP misconfiguration detected on [chars]: ([chars] [dec]-[dec][chars] [dec]-[dec])Explanation There was an LACP misconfiguration
Recommended Action No action is required.
Error Message LACP-3-LACP_MISCFG: LACP misconfiguration detected on [chars]: ([chars])Explanation There was an LACP misconfiguration
Recommended Action No action is required.
Error Message LACP-3-LACP_SUSPEND_HALF_DUPLEX_PORT: Port [chars] is in half duplex mode. suspend portExplanation LACP is not supported in half duplex mode. Suspend port
Recommended Action No action is required.
Error Message LACP-3-LACP_UPGRADE_READY_FAILED: Upgrade ready was returned failure.Explanation Upgrade ready event was returned failure since one of the ports in port channels were found to be in intermediate state.
Recommended Action No action is required.
Error Message LACP-3-PACKET_TRANSMIT_ERR: [chars]: Could not send LACP packet err=[dec]Explanation There was an error in sending LACP packet
Recommended Action No action is required.
Error Message LACP-3-SYN_COLL_DIS_EN: [chars] [[chars]]: SYNC, COLLECT and DISTRIBUTE flags enabled too early by partnerExplanation Potential interop issue. Partner system seems to have enabled sync as well collecting or distributing flags too early even before actor has selected an aggregator
Recommended Action No action is required.
Error Message LACP-3-SYSTEM_MAC_ERR: [chars]: Could not get system mac[[chars]]Explanation There was an error in acquiring system mac from VDC Mgr
Explanation LACP Service Disabled
Recommended Action No action is required.
Error Message LACP-5-LACP_ENABLED: LACP EnabledExplanation LACP Service Enabled
Recommended Action No action is required.
Error Message LACP-5-LACP_REMOTE_NOTIFY_SUCCESS: Remote notify event.Explanation Remote notify event was returned success.
Recommended Action No action is required.
Error Message LACP-5-LACP_SUSPEND_INDIVIDUAL: LACP port [chars] of port-channel [chars] not receiving any LACP BPDUs suspending (individual) portExplanation LACP suspend individual ports
Recommended Action No action is required.
Error Message LACP-5-LACP_UPGRADE_READY_SUCCESS: Upgrade ready was returned success.Explanation Upgrade ready event was returned success since all ports in port channels were found in steady state.
Recommended Action No action is required.
Error Message LACP-5-PORT_PRIORITY_CHANGED: [chars]: LACP port priority changed from [dec] to [dec]Explanation LACP port priority has been changed
Recommended Action No action is required.
Error Message LACP-5-SYSTEM_PRIORITY_CHANGED: LACP system priority changed from [hex] to [hex]Explanation Lc_fcfwd encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Lc_span_mgr encountered an error
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation LC CPU Cache errors.
Recommended Action No action is required.
Error Message LC_CFG-SLOT#-2-LC_CFG_ABORT: registration aborted with code [dec]Explanation Process lc_cfg_mgr aborted registration
Recommended Action No action is required.
Error Message LC_CFG-SLOT#-2-LC_CFG_EXITED: exited with code [dec]Explanation Fatal hardware error in port-channel configuration
Recommended Action Reset the module
Error Message LC_PORT_CHANNEL-SLOT#-0-IDX_FULL: D_IDX table full (current [dec], new [dec], total [dec])Explanation Programming error in port-channel configuration
Recommended Action Reset the module
Error Message LC_PORT_CHANNEL-SLOT#-3-LC_PORT_CHANNEL_ERROR: [chars]Recommended Action No action is required.
Error Message LC_PORT_CHANNEL-SLOT#-3-LC_PORT_CHANNEL_IDXMAP_FAILURE: could not lookup port index for interface [chars]Explanation This is a software error in message communication between two applications.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation RDL malloc failed : [chars]
Recommended Action No action is required.
Error Message LC_RDL-3-SYSLOG_CONTEXT_ERR: : [chars] [dec]Explanation RDL context error: [chars] [dec]
Recommended Action No action is required.
Error Message LC_RDL-3-SYSLOG_ERR: : [chars]Explanation RDL syslog errors : [chars]
Recommended Action No action is required.
Error Message LC_RDL-3-SYSLOG_EXIT: : [chars]Explanation RDL exiting on errors : [chars]
Recommended Action No action is required.
Error Message LC_RDL-3-SYSLOG_INIT_FAIL: : [chars] [chars]Explanation RDL Init Failed: [chars] [chars]
Recommended Action No action is required.
Error Message LC_RDL-3-SYSLOG_MTS_ERR: : [chars]Explanation RDL MTS errors : [chars]
Recommended Action No action is required.
Error Message LC_RDL-3-SYSLOG_MTS_REG_FAILED: : [dec] [dec]Explanation RDL Debug logs: [chars] [dec]
Recommended Action No action is required.
Error Message LC_RDL-6-SYSLOG_DEBUG_2: : [chars] [hex]Explanation RDL Debug logs: [chars] [dec]
Recommended Action No action is required.
Error Message LC_RDL-6-SYSLOG_INFO: : [chars]Explanation RDL Debug logs: [chars]
Recommended Action No action is required.
Error Message LC_RDL-6-SYSLOG_RESP_RCVD: : [chars] [dec]Explanation LDAP daemon is exiting.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Notifying Ldap server monitor status change
Recommended Action No action is required.
Error Message LDAP-5-LDAP_SERVER_STATUS: [chars] server [chars] with port [dec] status has changed from [chars] to [chars]. Server was in previous-state for [chars], and total dead time of the server is [chars]Explanation Flow creation failed
Recommended Action No action is required.
Error Message LIBBASE_SVC-5-IT_NEXUS_FAILURE: [chars]. [chars] bind failure. Reason: [chars]: [hex]Explanation IT Nexus bind failed
Recommended Action No action is required.
Error Message LIBBASE_SVC-5-IT_NEXUS_OPTIMUM_INTERFACE_LIMIT_REACHED: Interface [chars] exceeded the optimum flow limitExplanation Guardian Access failed
Recommended Action No action is required.
Error Message LIBGD-2-GD_CATASTROPHIC: Guardian catastrophic failure: [chars]Explanation Guardian catastrophic error
Recommended Action No action is required.
Error Message LIBGD-2-GD_INTR: Guardian Interrupt occurred: [chars]Explanation Interrupt occurred on the Guardian
Recommended Action No action is required.
Error Message LIBGD-2-SHUTDOWN: Guardian software process exiting: [chars]Explanation Disabled port successfully for guardian
Recommended Action No action is required.
Error Message LIBGD-6-EN_PORT: Guardian enable port done for inst:[dec] port:[dec]Explanation Enabled port for the Guardian
Recommended Action No action is required.
Error Message LIBGD-6-HW_INIT: GuardianHW initialization has been done for inst: [dec] port: [dec]Explanation Unlicensed feature [chars] has exceeded it's grace time period. Applications using will be shut down immediately.
Recommended Action Please install the license file to continue using the feature.
Explanation Feature [chars] has very limited time for expiry. Feature will expire in [dec] days and will be shut down.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-1-LOG_LIC_NO_LIC_ALERT: No license(s) present for feature [chars]. Application(s) running in grace-period and will be shut down in [dec] days.Explanation Feature [chars] has not been licensed. The feature will work for a grace period of [dec] days after which application(s) using the feature will be shut down.
Recommended Action Please install the license file to continue using the feature.
Explanation License manager exiting.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message LICMGR-2-LOG_LIC_INVALID_SERVER_LINE: License file [chars] contains invalid SERVER line. Contact TACExplanation Invalid SERVER line in license file.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message LICMGR-2-LOG_LIC_NVRAM_DISABLED: Licensing NVRAM is not available. Grace period will be disabled: [chars]Explanation The Supervisor NVRAM block may have a hardware problem and may need to be replaced
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message LICMGR-2-LOG_LIC_VENDOR_DOWN: License file contains invalid SERVER line. Vendor daemon downExplanation Application [chars1] has not been licensed. The application will work for a grace period of [dec] days after which it will be shut down unless a license file for feature [chars2] is installed.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-3-LOG_LIC_FILE_MISSING: License file(s) missing for feature [chars].Explanation One or more license files for feature [chars] are missing and must be reinstalled.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-3-LOG_LIC_INVALID_HOSTID: Invalid license hostid VDH=[chars] for feature [chars].Explanation Feature [chars2] has a license with an invalid license hostid VDH=[chars1]. This can occur if a supervisor card with licensed features for one switch is installed on another switch.
Recommended Action No action is required.
Error Message LICMGR-3-LOG_LIC_LICENSE_EXPIRED: Evaluation license expired for feature [chars].Explanation The named feature has exceeded it's evaluation time period. Applications using the license will be shut down after a grace period.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-3-LOG_LIC_MESSAGE_ERROR: could not handle message: [chars] of type [dec] from addr [dec]:[dec].Explanation Could not handle a IPC message [chars] of type [dec1] sent by a component running on node [dec2] with sap [dec3].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message LICMGR-3-LOG_LIC_NO_LIC: No license(s) present for feature [chars]. Application(s) shut down in [dec] days.Explanation Feature [chars] has not been licensed. The feature will work for a grace period of [dec] days after which application(s) using the feature will be shut down.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-3-LOG_LIC_SERVER_DOWN: License Server Down [dec]Explanation A connection to the license server was lost.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message LICMGR-3-LOG_LIC_SPROM_LIC: Feature [chars] issued [dec] licenses without a valid license file.Explanation Feature [chars] has been licensed [dec] times without a valid license file. This means one or more license files are missing for feature [chars] and must be reinstalled.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-3-LOG_LIC_TOO_MANY_LIC: Only [dec] licenses are supported for [chars] feature, where as [dec] licenses are installed.Explanation More licenses are installed than allowed.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation Application [chars1] will exceed it's evaluation time period in [dec] days and will be shut down after a grace period unless a permanent license for feature [chars2] is installed.
Recommended Action Please install the license file to continue using the feature.
Error Message LICMGR-4-LOG_LIC_LICENSE_EXPIRY_WARNING: Evaluation license for feature [chars] will expire in [dec] days.Explanation Feature [chars] will exceed it's evaluation time period in [dec] days and will be shut down.
Recommended Action Please install the license file to continue using the feature.
Explanation When a license expires, auto checkpoint is created to prevent configuration loss.
Recommended Action Rollback can be done to the created checkpoint when a new license is installed.
Error Message LICMGR-6-LOG_LIC_FEATURE_CLEARED: Cleared [dec] license(s) for feature [chars].Explanation Uninstalled [dec] license(s) for feature [chars].
Recommended Action Use the 'show license usage' command to verify this license feature removal.
Error Message LICMGR-6-LOG_LIC_FEATURE_INSTALLED: Installed [dec] license(s) for feature [chars].Explanation Installed [dec] license(s) for feature [chars].
Recommended Action Use the 'show license usage' command to verify this license feature installation.
Error Message LICMGR-6-LOG_LIC_LICENSE_CLEARED_ALL: Cleared all licenses.Explanation Cleared all license files.
Recommended Action No action is required.
Error Message LICMGR-6-LOG_LIC_LICENSE_CLEARED: Cleared license file [chars].Explanation Uninstalled the named license file.
Recommended Action Use the 'show license' command to verify this license removal.
Error Message LICMGR-6-LOG_LIC_LICENSE_INSTALLED: Installed license file [chars].Explanation Installed the named license file.
Recommended Action Use the 'show license' command to verify this license installation.
Explanation MPLS_LDP Service Disabled
Recommended Action No action is required.
Error Message LDP-5-LDP_ENABLED: LDP EnabledExplanation Multiple peers detected on an interface
Recommended Action No action is required.
Error Message LLDP-3-INVALID_DCBXP_RECEIVED: Received an invalid DCBXP on [chars]Explanation Received an invalid DCBXP on an interface
Recommended Action No action is required.
Error Message LLDP-3-INVALID_LLDP_RECEIVED: Received an invalid LLDP on [chars]Explanation Received an invalid LLDP on an interface
Recommended Action No action is required.
Error Message LLDP-3-LLDP_INTERNAL_ERROR: LLDP internal error: [chars]Explanation LLDP Service Disabled
Recommended Action No action is required.
Error Message LLDP-5-LLDP_ENABLED: LLDP EnabledExplanation LLDP Service Enabled
Recommended Action No action is required.
Error Message LLDP-5-SERVER_ADDED: Server with Chassis ID [chars] Port ID [chars] management address [chars] discovered on local port [chars] in vlan [dec] with enabled capability [chars]Explanation A new peer is discovered
Recommended Action No action is required.
Error Message LLDP-5-SERVER_REMOVED: Server with Chassis ID [chars] Port ID [chars] on local port [chars] has been removedExplanation Remote change detected on an interface
Recommended Action No action is required.
Error Message LLDP-6-DETECT_REMOTE_DCBXP_CHANGE: Remote DCBXP change detected on [chars]Explanation Mcast is shutting down
Recommended Action The action depends on the situation. The multicast process can shut down gracefully because of a system restart (in which case no action needs to take place) or because of a failure. The message associated with the syslog should be self explanatory to understand the reason for the shutdown. If the process is able to restart properly, there is no immediate harm for the system stability and the suggested action is to report the syslog event together with an explanation of the operations most recently performed on the system.
Explanation Mcast has received a malformed/unrecognized message
Recommended Action No action is required.
Error Message MCAST-5-START: Process has been startedExplanation MCECTEST has hit an assert condition at file [chars]
Recommended Action No action is required.
Error Message MCECTEST-3-INIT_FAIL: [chars]Explanation MCECTEST Initialization failed. due to [chars]
Recommended Action No action is required.
Error Message MCECTEST-3-INTERNAL_ERR: [chars]Explanation MCECTEST encountered an internal error due to [chars]
Recommended Action No action is required.
Error Message MCECTEST-3-MTS_ERR: [chars]Explanation MCECTEST encountered an MTS error due to [chars]
Explanation MCECTEST Service Disabled
Recommended Action No action is required.
Error Message MCECTEST-5-MCECTEST_ENABLED: MCECTEST EnabledExplanation Some critical error
Recommended Action No action is required.
Error Message MCM-2-MCM_REPLICATION_DISABLED: Proxy layer-3 modules are not available for replication. Proxy layer-3 multicast replication is disabled.Explanation Replication is disabled
Recommended Action No action is required.
Error Message MCM-2-MCM_REQ_RESP_ERROR: Error ([hex]: [chars]) while communicating with component :[chars], opcode: [chars] (for: [chars])Explanation Error in request-response handshake
Recommended Action No action is required.
Error Message MCM-2-MCM_ROUTING_DISABLED: Proxy layer-3 modules are not available for routing. Proxy layer-3 forwarding is disabled.Explanation Replication is enabled
Recommended Action No action is required.
Error Message MCM-6-MCM_ROUTING_ENABLED: Proxy layer-3 modules are UP and available for routing. Proxy layer-3 forwarding is enabled.Explanation Routing is enabled
Recommended Action No action is required.
Error Message MCM-6-MCM_ROUTING_ENABLED: Proxy layer-3 modules are UP. Routing is Enabled.Explanation PIXM returned duplicate DI.
Recommended Action No action is required.
Error Message MFDM-2-DOWNLOAD_TIMEOUT: Download of L2/L3 route databases timed out : download_in_progress_slots [hex] download_in_progress_db [hex]Explanation Download of L2/L3 route databases timed out. Download triggered by VMM insert request.
Recommended Action No action is required.
Error Message MFDM-2-INTERNAL_ERROR: MFDM-[chars] Internal error : show system internal mfdm errors for more informationExplanation MFDM PD hit a internal error. show system internal mfdm errors for futher analysis.
Recommended Action No action is required.
Error Message MODULE-2-LCM_PRE_UPGRADE_GENERAL_FAIL: Pre upgrade message fails seq [dec]Explanation Pre upgrade message failed.
Recommended Action No action is required.
Error Message MODULE-2-LCM_UPGRADE_DONE_GENERAL_FAIL: Upgrade done message fails SAP [chars]Explanation Upgrade ready message failed.
Recommended Action No action is required.
Error Message MODULE-2-LCM_UPGRADE_OVER_FAIL: Upgrade over message returned [dec] [hex] for SAP [dec]Explanation Upgrade done message failed.
Recommended Action No action is required.
Error Message MODULE-2-LCM_UPGRADE_READY_FAIL: Upgrade ready message returned [dec] [hex] for SAP [dec]Explanation Upgrade ready message failed.
Recommended Action No action is required.
Error Message MODULE-2-LCM_UPGRADE_READY_GENERAL_FAIL: Upgrade ready message fails SAP [chars]Explanation Upgrade ready message failed.
Recommended Action No action is required.
Error Message MODULE-2-MOD_DIAG_FAIL: Module [dec] (serial: [chars]) reported failure [chars] due to [chars] in device [dec] (device error [hex])Explanation The module in slot [decimal digit] reported a failure in the runtime diagnostic. Module manager is going to power cycle the module.
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-2-MOD_DNLD_FAIL: Image download failed for module [dec] (serial: [chars])Explanation Module [decimal digit] failed to download a new image from the supervisor.
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-2-MOD_FAIL: Initialization of module [dec] (serial: [chars]) failedExplanation Module [decimal digit] reported a failure during the initialization phase and will be powered down.
Recommended Action Collect information about the module by issuing the commands 'show module_internal all module <module number>'.
Error Message MODULE-2-MOD_MAJORSWFAIL: Module [dec] (serial: [chars]) reported a critical failure in service [chars]Explanation A critical failure in service [string] happened at module [decimal digit] is going to reset the module [decimal digit].
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-2-MOD_MINORSWFAIL: Module [dec] (serial: [chars]) reported a failure in service [chars]Explanation A non-critical failure in service [string] happened at module [decimal digit] is not going to reset the module [decimal digit].
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-2-MOD_NOT_ALIVE: Module [dec] not responding... resetting (serial: [chars])Explanation Module [decimal digit] is not replying to the hello message: module manager is then going to reset the module.
Recommended Action No action is required.
Error Message MODULE-2-MOD_REGFAILED: Registration failed for module [dec]Explanation Module [decimal digit] sent the registration message notifying a failure.
Recommended Action Collect module internal information by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-2-MOD_SOMEPORTS_FAILED: Module [dec] (serial: [chars]) reported failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] (error [hex])Explanation Module [decimal digit] reported a failure in the runtime diagnostic due to failure in some of the ports.
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-2-MOD_UNKNOWN: Module type [[dec]] in slot [dec] is not supportedExplanation The software card id of module [decimal digit] is not supported by the supervisor.
Recommended Action Collect information about the module by issuing the commands 'show module internal all module [decimal digit]'
Error Message MODULE-2-XBAR_DIAG_FAIL: Xbar [dec] (serial: [chars]) reported failure [chars] due to [chars] in device [dec] (device error [hex])Explanation The xbar in slot [decimal digit] reported a failure in the runtime diagnostic. Module manager is going to power cycle the module.
Recommended Action Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.
Error Message MODULE-2-XBAR_FAIL: Initialization of xbar [dec] (serial: [chars]) failedExplanation Xbar [decimal digit] reported a failure during the initialization phase and will be powered down.
Recommended Action Collect information about the module by issuing the commands 'show module_internal all xbar <module number>'.
Error Message MODULE-2-XBAR_SOMEPORTS_FAILED: Xbar [dec] (serial: [chars]) reported failure on ports [dec]/[dec]-[dec]/[dec] ([chars]) due to [chars] in device [dec] (error [hex])Explanation Xbar [decimal digit] reported a failure in the runtime diagnostic due to failure in some of the ports.
Recommended Action Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.
Error Message MODULE-2-XBAR_UNKNOWN: Xbar type [[dec]] in slot [dec] is not supportedExplanation The software card id of xbar [decimal digit] is not supported by the supervisor.
Recommended Action Collect information about the module by issuing the commands 'show module internal all xbar [decimal digit]'
Explanation LCM encountered an error while executing a sequence for a module.
Recommended Action No action is required.
Error Message MODULE-3-MOD_SRG_NOT_COMPATIBLE: Module [dec] (serial: [chars]) firmware is not compatible with supervisor, downloading new imageExplanation The software version of module [decimal digit] is not supported by the supervisor.
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Explanation Module [decimal digit] reported a warning in the runtime diagnostic due to failure in some of the ports.
Recommended Action Collect information about the module by issuing the command 'show module internal all module [decimal digit]'.
Error Message MODULE-4-XBAR_WARNING: Xbar [dec] (serial: [chars]) reported warning [chars] due to [chars] in device [dec] (device error [hex])Explanation Xbar [decimal digit] reported a warning in the runtime diagnostic due to failure in some of the ports.
Recommended Action Collect information about the module by issuing the command 'show module internal all xbar [decimal digit]'.
Explanation Module [decimal digit] is ready to be configured and be able to switch traffic.
Recommended Action No action is required.
Error Message MODULE-5-LCM_MODULE_UPGRADE_END: Upgrade of module [dec] endedExplanation Upgrade of the module has ended.
Recommended Action No action is required.
Error Message MODULE-5-LCM_MODULE_UPGRADE_START: Upgrade of module [dec] startedExplanation Upgrade of the module has been started by installer
Recommended Action No action is required.
Error Message MODULE-5-MOD_OK: Module [dec] is online (serial: [chars])Explanation Module [decimal digit] is ready to be configured and be able to switch traffic.
Recommended Action No action is required.
Error Message MODULE-5-MOD_REINIT: Re-initializing module [dec] (serial: [chars])Explanation Module [decimal digit] reported a failure during the initialization phase and will be rebooted.
Recommended Action Collect information about the module by issuing the commands 'show module_internal all module <module number>'.
Error Message MODULE-5-MOD_RESTART: Module [dec] is restarting after image downloadExplanation Module [decimal digit] completed image download and is restarting.
Recommended Action No action is required.
Error Message MODULE-5-MOD_STARTUP_CFG_MISMATCH: The startup configuration cannot be applied to a different module type for module [dec] (serial: [chars]). [chars] module is replacing [chars].Explanation The startup configuration for module [decimal digit] contains information about a different type of module instead of containing information about the current one.
Recommended Action No action is required.
Error Message MODULE-5-STANDBY_SUP_OK: Supervisor [dec] is standbyExplanation Module [decimal digit] is ready to be configured and be able to switch traffic.
Recommended Action No action is required.
Error Message MODULE-5-XBAR_OK: Xbar [dec] is online (serial: [chars])Explanation Xbar [decimal digit] is ready to be configured and be able to switch traffic.
Recommended Action No action is required.
Error Message MODULE-5-XBAR_REINIT: Re-initializing xbar [dec] (serial: [chars])Explanation Xbar [decimal digit] reported a failure during the initialization phase and will be rebooted.
Recommended Action Collect information about the module by issuing the commands 'show module_internal all xbar <module number>'.
Explanation Notification is being sent to remove the module configurations.
Recommended Action No action is required.
Error Message MODULE-6-MOD_REG_OK: Registration succeeded for module [dec]Explanation Module [decimal digit] sent a successful registration message.
Explanation Session is down, no further traffic will be spanned.
Recommended Action No action is required.
Error Message MONITOR-6-ETH_SPAN_SESSION_ERROR: Session [dec] is having error. Reason [chars]Explanation The session is experiencing a problem.
Recommended Action Delete the session and try to reconfigure it
Error Message MONITOR-6-ETH_SPAN_SESSION_UP: Session [dec] is up.Explanation Session is up now. You can monitor Spanned traffic at the destination ports
Explanation The DDB commit failed
Recommended Action No action is required.
Error Message NFM-2-DDB_FAILURE: DDB failure: [chars]Explanation A DDB generated failure
Recommended Action No action is required.
Error Message NFM-2-EXITING: Exit reason: [chars]Explanation The NFM service process has exited due to [char]. The process has probably been restarted automatically.
Recommended Action No action is required.
Error Message NFM-2-INIT_FAIL: NFM Service Init failed: [chars]Explanation NFM Service initialization failed. [chars] explains the reason for the failure.
Recommended Action No action is required.
Error Message NFM-2-MALLOC_ERROR: Function [chars]: Size [dec] bytesExplanation The NFM service could not allocate memory.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NFM-2-PSS_ERROR: [chars]: PSS ret. val=[dec]Explanation The NFM service encountered error while operating on a persistent storage database.
Recommended Action No action is required.
Error Message NFM-2-VERIFY_FAIL: Verify failed - Client [hex], Reason: [chars], Interface: [chars]Explanation The DDB generated error
Recommended Action No action is required.
Error Message NFM-3-FEATURE_MANAGER_ERROR: [chars]: An error occurred processing a Feature Manager msg - error [chars]Explanation An error occurred while processing a message from FEATURE Manager
Recommended Action No action is required.
Error Message NFM-3-HANDLE_IN_USE: [chars]: name: [chars]Explanation The NFM service encountered a handle that was in use while reading a persistent storage database.
Recommended Action No action is required.
Error Message NFM-3-INVALID_HANDLE: [chars]: handle =[hex]Explanation The NFM service encountered an invalid handle in a persistent storage database.
Recommended Action No action is required.
Error Message NFM-3-MONITOR_NOT_FOUND: Monitor with handle [hex] from source [hex]Explanation An Export Msg from a Linecard contained an invalid Monitor handle
Recommended Action No action is required.
Error Message NFM-3-MTS_ERROR: NFM encountered the following MTS error: [chars]Explanation NFM Service encountered an MTS error. [chars] specifies the context where the error occurred.
Recommended Action No action is required.
Error Message NFM-3-NFM_DDB_ERROR: DDB error: [chars]Explanation The DDB generated error
Recommended Action No action is required.
Error Message NFM-3-PSS_CORRUPTED: [chars] PSS found corruptedExplanation The NFM service has detected corruption in one of its persistent information database. The database would be recreated.
Recommended Action No action is required.
Error Message NFM-3-VLAN_PARSE_ERROR: [chars]: An error occurred processing a VLAN Mgr Parse msg [hex]Explanation An error occurred while processing a message from VLAN Manager
Explanation The DDB generated warning
Recommended Action No action is required.
Error Message NFM-4-LICENSE_EXPIRED: The License has expired.Explanation The NFM service requires a License to run and exits when the License expires.
Recommended Action No action is required.
Error Message NFM-4-NFM_DDB_WARNING: DDB warning: [chars]Explanation The DDB generated warning
Recommended Action No action is required.
Error Message NFM-4-PSS_VERSION_MISMATCH: PSS [dec] Code [dec]Explanation There was a version mismatch between the NFM service and one of its persistent storage databases. The persistent information has been translated to the new format.
Explanation NetFlow Feature Disabled.
Recommended Action No action is required.
Error Message NFM-5-FEATURE_ENABLED: NetFlow Enabled.Explanation The NFM service on the standby supervisor became active and it is ready to serve client requests.
Recommended Action No action is required.
Error Message NFM-6-BECAME_STDBY: Became STANDBY from active modeExplanation The NFM service became standby from active mode.
Recommended Action No action is required.
Error Message NFM-6-DDB_NOTIF: DDB notification: [chars]Explanation The DDB generated notification
Recommended Action No action is required.
Error Message NFM-6-FAILED_TO_SEND_HEARTBEAT: Failed to send heartbeat to system manager: Reason=[chars]Explanation The NFM service was unable to send heartbeat to the system manger
Recommended Action No action is required.
Error Message NFM-6-NFM_DDB_NOTIF: DDB notification: [chars]Explanation The DDB generated notification
Recommended Action No action is required.
Error Message NFM-6-SERVICE_UP: Initialized [chars]Explanation The NFM service is up and ready The service was initialized in [char] mode.
Recommended Action No action is required.
Error Message NFM-6-SRV_EXIT: NFM Service shutting down gracefullyExplanation NFM Service is shutting down gracefully. This is an informational message.
Recommended Action No action is required.
Error Message NFM-6-SWITCH_OVER: Switching Over to other Sup.Explanation The NFM service has successfully switched over to the standby supervisor card.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NFP-SLOT#-2-NF_ERR: [chars]([dec]): nfp error. [chars]Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NFP-SLOT#-2-NF_FIB_ERR: [chars]([dec]): fib error. [chars] Error Message NFP-SLOT#-2-NF_NDE_ERR: [chars]([dec]): nde error. [chars] Error Message NFP-SLOT#-2-NF_NFM_ERR: [chars]([dec]): nfm error. [chars] Error Message NFP-SLOT#-2-NF_QOS_ERR: [chars]([dec]): qos error. [chars]Explanation The system has detected an error.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Recommended Action show diagnostics result module all
Error Message NOHMS-2-NOHMS_DIAG_ERR_PS_FAIL: [chars]Explanation Power Supply has failed or has been shutdown
Recommended Action Please perform a 'show environment power' to collect more information. Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message NOHMS-2-NOHMS_DIAG_ERR_PS_RECOVERED: [chars]Explanation Power Supply recovered from minor alarm
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_DIAG_ERR_PS_VOLT: [chars]Explanation Invalid input voltage on power supply. Only 220V input voltage is supported.
Recommended Action Please perform show environment
Error Message NOHMS-2-NOHMS_ENV_ERROR: [chars]Explanation Environmental erorr
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_ALL_FAN_UP: [chars]Explanation Fan recovered from system minor alarm
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FANS_DOWN: [chars]Explanation System major alarm on fans. Multiple fan modules are missing or have failed.
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FANS_UP: [chars]Explanation Fan recovered from system major alarm.
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_DIR: [chars]Explanation Fan direction mismatch between modules
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_DOWN: [chars]Explanation System minor alarm on fans. Fan module is missing or has failed.
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_MAJ: [chars]Explanation Multiple fan modules are down. This can lead to overheating and temperature alarms
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_MIN: [chars]Explanation Fan module failed POST
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_READ: [chars]Explanation Fan module failed to read TACH
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_RECOVERED: [chars]Explanation Fan recovered from system minor alarm.
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_SPEED: [chars]Explanation System minor alarm on fans. Fan speed is out of range.
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_FAN_WRITE: [chars]Explanation System minor alarm on fans. Failed to set fan speed.
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_ERR_TEMPMAJALRM: [chars]Explanation Module in slot [decimal digit] has exceeded major temperature threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message NOHMS-2-NOHMS_ENV_ERR_TEMPMINALRM: [chars]Explanation Module in slot [decimal digit] has exceeded minor temperature threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message NOHMS-2-NOHMS_ENV_ERR_TEMPOK: [chars]Explanation Module in slot [decimal digit] recovered from major temperature threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message NOHMS-2-NOHMS_ENV_ERR_TEMPRECOVER: [chars]Explanation Module in slot [decimal digit] recovered from major temperature threshold. Minor threshold still exceeded.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message NOHMS-2-NOHMS_ENV_ERR_TEMP_SENSOR_FAIL: [chars]Explanation Temperature sensor failed POST
Recommended Action Show environment
Error Message NOHMS-2-NOHMS_ENV_FEX_OFFLINE: [chars]Recommended Action Show inventory
Error Message NOHMS-2-NOHMS_ENV_FEX_ONLINE: [chars]Explanation Serious errors which affect all normal operations occurred
Explanation Unexpected errors which affect some normal operations occurred
Recommended Action No action is required.
Error Message NPC-SLOT#-5-LOG_NPC_NVP_FSM: Illegal event received: [chars]Explanation Illegal event received in NPC_NVP FSM
Recommended Action No action is required.
Error Message NPC-SLOT#-5-LOG_NPC_VSAN_FSM: Illegal event received: [chars]Explanation Due to port flaps, link outages, switch restart etc. a CFS peer switch of NPV was lost. The current configuration changes would not be applied to this peer until the peer merges with this switch. The CFS merge may fail if the configuration at the lost peer conflicts with the changes made in this session. It is recommended that the user abort this CFS session using ivr abort command and then re-enter the configuration changes.
Recommended Action No action is required.
Error Message NPV-2-NPV_DISABLE_FAILED: NPV could not disabled : [chars] [chars]Explanation NPM could not disabled due to the reason specified. Please try again.
Recommended Action No action is required.
Error Message NPV-2-NPV_ENABLE_FAILED: NPV could not enabled : [chars] [chars]Explanation NPM could not enabled due to the reason specified. Please try again.
Recommended Action No action is required.
Error Message NPV-2-NPV_EXITED: NPV process exited in file [chars] at Line [chars]:[chars]Explanation NPM process encountered a critical error as specified, and so NPV process cannot continue.
Explanation ACL update request initiated by the NPV process has failed
Recommended Action No action is required.
Error Message NPV-3-CFS_INVALID_PAYLOAD_RECEIVED: NPV received invalid payload from CFSExplanation NPV process received invalid payload from CFS.
Recommended Action No action is required.
Error Message NPV-3-CLEAR_FAILED: [chars]Explanation An error occurred while clearing the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-COMMIT_FAILED: [chars]Explanation An error occurred while committing configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-COMMIT_PARTIALLY_FAILED: [chars]Explanation An error occurred while committing configuration. Configuration could not be committed on some switches. The reason for the failure : [chars]. Configuration can be inconsistent in the fabric.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-COMMIT_REJECTED: [chars]Explanation Commit request received from remote switch is rejected. The reason for the failure: [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-FC2_SEND_FAILED: [chars]Explanation NPV process could send an FC2 message.
Recommended Action No action is required.
Error Message NPV-3-F_RJT_SENT: [chars]Explanation NPV process sent an F_RJT frame.
Recommended Action No action is required.
Error Message NPV-3-INTERNAL_ERROR: Internal error: [chars]Explanation NPV process encountered a general error, one that does not fall in any of the categories. [chars] describes the error and its context.
Recommended Action No action is required.
Error Message NPV-3-LCP_PROGRAMMING_FAILED: [chars]Explanation LCP programming request initiated by the NPV process has failed
Recommended Action No action is required.
Error Message NPV-3-LOCK_FAILED: [chars]Explanation An error occurred while acquiring the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-LS_RJT_RCVD: [chars]Explanation NPV process received an LS_RJT frame.
Recommended Action No action is required.
Error Message NPV-3-LS_RJT_SENT: [chars]Explanation NPV process sent an LS_RJT frame.
Recommended Action No action is required.
Error Message NPV-3-MALLOC_FAILED: [chars]Explanation NPV process could not allocate memory
Recommended Action No action is required.
Error Message NPV-3-MERGE_ACTIVATION_FAILED: [chars]Explanation An error occurred while activating merged configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-MERGE_FAILED: [chars]Explanation An error occurred while merging configuration. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message NPV-3-MTS_SEND_FAILED: [chars]Explanation NPV process could not send an MTS message.
Recommended Action No action is required.
Error Message NPV-3-NPIV_DISABLE_FAILED: [chars]Explanation NPIV feature could not be disabled.
Recommended Action No action is required.
Error Message NPV-3-NPV_CFS_IPV4_ENABLE_FAILED: CFS IPv4 distribution enable failed because [chars]Explanation NPV CFS distribution might not work. Try enabling it again on the command line. Make sure cfs distribution is enabled.
Recommended Action No action is required.
Error Message NPV-3-PORT_BRINGUP_FAILED: [chars]Explanation NPV process has failed to bringup the port
Recommended Action No action is required.
Error Message NPV-3-PORT_REINIT_FAILED: [chars]Explanation Port reinit request initiated by the NPV process has failed
Recommended Action No action is required.
Error Message NPV-3-UNLOCK_FAILED: [chars]Explanation An error occurred while releasing the lock. The reason for the failure : [chars]
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Explanation This syslog is printed when the external interface fails to come up due to NPIV feature not enabled on the upstream switch.
Recommended Action Verify and enable NPIV feature in upstream switch.
Error Message NPV-4-NPV_PORT_VSAN_MISMATCH_ON_UPSTREAM_LINK: [chars]Explanation This syslog is printed when the external interface fails to come up due to upstream port VSAN mis-match with the upstream switch.
Recommended Action Make sure port VSAN is same on both sides of this external link
Explanation An assertion failed in NPV code
Recommended Action No action is required.
Error Message NPV-5-FLEXATTACH_VPWWN_AUTO_ASSIGNED: A virtual port WWN [chars] has been automatically assigned to interface [chars]Explanation The virtual port WWN will be used as port WWN for devices logging in on this interface.
Recommended Action No action is required.
Error Message NPV-5-FLEXATTACH_VPWWN_MANUALLY_ASSIGNED: A virtual port WWN [chars] has been manually assigned to interface [chars]Explanation The virtual port WWN will be used as port WWN for devices logging in on this interface.
Recommended Action No action is required.
Error Message NPV-5-FLEXATTACH_VPWWN_UNASSIGNED: The virtual port WWN has been unassigned from interface [chars]Explanation The physical port WWN will be used as port WWN for devices logging in on this interface.
Recommended Action No action is required.
Error Message NPV-5-FRAME_DISCARDED: [chars]Explanation NPV process discarded an FC2 frame.
Recommended Action No action is required.
Error Message NPV-5-NPV_LOAD_BALANCE_REINIT: Server ports reinitialized : [chars]Explanation Server ports are reinitialized to balance the loads on the external interfaces.
Recommended Action No action is required.
Error Message NPV-5-UNEXPECTED_EVENT: [chars]Explanation NPV process has received an unexpected event in the current state.
Explanation NPV process sent an ABTS frame.
Recommended Action No action is required.
Error Message NPV-6-ELS_CMD_SENT_TO_CORE: [chars]Explanation NPV process sent an ELS frame to the core switch.
Recommended Action No action is required.
Error Message NPV-6-ELS_CMD_SENT_TO_SRV: [chars]Explanation NPV process sent an ELS frame to the server.
Recommended Action No action is required.
Error Message NPV-6-EXT_IF_SELECTED: [chars]Explanation NPV process has selected an external interface to forward either all frames received on a server interface or frames received from a specific port WWN.
Recommended Action No action is required.
Error Message NPV-6-FABRIC_PROXY_LOGO_SENT: [chars]Explanation NPV process sent a LOGO frame to the device as the corresponding external interface went down.
Recommended Action No action is required.
Error Message NPV-6-FDISC_RCVD: [chars]Explanation NPV process received an FDISC frame.
Recommended Action No action is required.
Error Message NPV-6-FDISC_SENT: [chars]Explanation NPV process sent an FDISC frame to the core switch.
Recommended Action No action is required.
Error Message NPV-6-FLOGI_RCVD: [chars]Explanation NPV process received an FLOGI frame.
Recommended Action No action is required.
Error Message NPV-6-INTERNAL_FLOGI_SENT: [chars]Explanation NPV process sent an internal FLOGI frame to the core switch on an external interface.
Recommended Action No action is required.
Error Message NPV-6-LOGO_RCVD: [chars]Explanation NPV process received a LOGO frame.
Recommended Action No action is required.
Error Message NPV-6-LOGO_SENT: [chars]Explanation NPV process sent a LOGO frame.
Recommended Action No action is required.
Error Message NPV-6-LS_ACC_RCVD: [chars]Explanation NPV process received an LS_ACC frame.
Recommended Action No action is required.
Error Message NPV-6-LS_ACC_SENT: [chars]Explanation NPV process sent an LS_ACC frame.
Recommended Action No action is required.
Error Message NPV-6-MTS_NOTIF_RCVD: [chars]Explanation NPV process received an MTS notification.
Recommended Action No action is required.
Error Message NPV-6-MTS_NOTIF_SENT: [chars]Explanation NPV process sent an MTS notification.
Recommended Action No action is required.
Error Message NPV-6-MTS_REQ_RCVD: [chars]Explanation NPV process received an MTS request.
Recommended Action No action is required.
Error Message NPV-6-MTS_REQ_SENT: [chars]Explanation NPV process sent an MTS request.
Recommended Action No action is required.
Error Message NPV-6-MTS_RESP_RCVD: [chars]Explanation NPV process received an MTS response.
Recommended Action No action is required.
Error Message NPV-6-MTS_RESP_SENT: [chars]Explanation NPV process sent an MTS response.
Recommended Action No action is required.
Error Message NPV-6-NPIV_DISABLED: [chars]Explanation NPIV feature has been disabled.
Recommended Action No action is required.
Error Message NPV-6-NPIV_ENABLED: [chars]Explanation NPIV feature has been enabled.
Recommended Action No action is required.
Error Message NPV-6-NPV_ENABLE_DISABLE_IN_PROGRESS: [chars]Explanation NPV feature enable/disable is in progress. This syslog is printed at the beginning of various significant phases.
Recommended Action No action is required.
Error Message NPV-6-NPV_LOAD_BALANCE_TIMER_START: (Re)starting automatic load balancing timer for [dec] secondsExplanation Timer started for upon external interface up or server interface down. When the timer goes off some of the server interfaces may be reinitialized to evenly distribute the server interfaces amongst the eligible external interfaces.
Recommended Action No action is required.
Error Message NPV-6-SERVER_PROXY_LOGO_SENT: [chars]Explanation NPV process sent a LOGO frame to the core switch as the server interface went down.
Explanation CFS request is received. The WWN of the switch originated this request and the rr-token of the request are provided in the syslog message.
Recommended Action No action is required.
Error Message NPV-7-CFS_RESP_SENT: [chars]Explanation CFS response is sent. The rr-token of the corresponding request and the status are provided in the syslog message
Explanation NTP syslog Critial Error : [chars].
Recommended Action No action is required.
Error Message NTP-2-NTP_SYSLOG_INIT_FAIL: : [chars] [chars]Explanation NTP Initialization Failed: [chars] [chars].
Recommended Action No action is required.
Error Message NTP-2-NTP_SYSLOG_NO_RESP_FROM_LC: from LC[dec] for [chars]Explanation NTP did not receive response from the linecard for the request sent.
Explanation NTP syslog allocation failed : [chars].
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_ERR_EXT: : [chars] [chars]Explanation NTP syslog Error Exit : [chars] [dec].
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_ERR: : [chars]Explanation NTP syslog Error : [chars].
Recommended Action No action is required.
Error Message NTP-3-NTP_SYSLOG_MTS_ERR: : [chars]Explanation NTP syslog created : [chars] [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_EXIT: : [chars]Explanation NTP syslog Exit : [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_LOGGING: : [chars]Explanation NTP logging : [chars].
Recommended Action No action is required.
Error Message NTP-6-NTP_SYSLOG_WARN: : [chars]Explanation NVP daemon informational message
Recommended Action No action is required.
Error Message NVP-6-STARTING: deamon startedExplanation Octopus received packets with CRC error from fabric
Explanation OTM process failed to register with eem, exiting now
Explanation Status of tracking object [dec] changed to [chars]
Explanation OTM process is terminated
Recommended Action No action is required.
Error Message OTM-6-OTM_OBJ_ADD: : Tracking object [dec] configured, status of the object [chars]Explanation Tracking Object [dec] configured, status of the object [chars]
Recommended Action No action is required.
Error Message OTM-6-OTM_OBJ_REM: : Tracking object [dec] removedExplanation Tracking Object [dec] removed
Recommended Action No action is required.
Error Message OTM-6-OTM_STARTED: OTM process startedExplanation OTM process is up and running
Recommended Action No action is required.
Error Message OTM-6-OTM_TRACK_START: Client started tracking object [dec]Explanation Client has started tracking object [dec]
Recommended Action No action is required.
Error Message OTM-6-OTM_TRACK_STOP: Client stopped tracking object [dec]Explanation Clock module on chassis deteted a failure and switched to redundant clock module.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-0-CHASSIS_CLKSWRESET: Switch reset due to clock switchExplanation Chassis clock source has failed and system will be reset. System will automatically start using redundant clock module.
Recommended Action Please refer to the platform document on clock modules.
Error Message PFMA-0-CHASSIS_CLKSW_MODULE_RESET: Modules reset due to clock switchExplanation Chassis clock source has switched and all Vegas line cards will be reset. System will automatically continue using redundant clock module.
Recommended Action Please refer to the platform document on clock modules.
Error Message PFMA-0-FAIL_REMOVED: Fan module removed. Fan[dec] has been absent for [dec] secondsExplanation Fan module is removed. This could lead to temperature alarms.
Recommended Action Replace the fan module ASAP.
Error Message PFMA-0-MOD_TEMPMAJALRM: [chars] reported Major temperature alarm. Sensor=[dec] Temperature=[dec] MajThreshold=[dec]Explanation Module in slot [decimal digit] exceeded major temperature threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-0-MOD_TEMPSHUTDOWN: [chars] powered down due to major temperature alarm for Sensor [dec].Explanation Module in slot [decimal digit] shutdown due to temperature exceeding major threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-0-SUP_SPROM_ERROR: Unable to read SPROM for Sup in slot [dec]Explanation The supervisor in slot [decimal digit] was not able to read its SPROM.
Recommended Action No action is required.
Error Message PFMA-0-SUP_WRONGSLOTNUM: Supervisor powered up in WRONG SLOT:[dec] (Serial number [chars])Explanation The supervisor is comming up in wrong slot [decimal digit].
Recommended Action No action is required.
Error Message PFMA-0-SYS_LC_DRIVER_LOAD_FAILED: Failed to load linecard module driversExplanation Failed to load drivers.
Recommended Action Image is possibly corrupt. Try to load a different image.
Error Message PFMA-0-SYS_RESET: [chars] System shutdown in [dec] secondsExplanation System shutdown in [decimal digit] seconds.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in [dec] seconds due to fan dir mismatchExplanation System shutdown in [decimal digit] seconds due to mismatch in direction between fan and ps module.
Recommended Action Please perform a 'show env fan' to collect more information.
Error Message PFMA-0-SYS_SHUTDOWN_FAN_REMOVAL: System shutdown in [dec] seconds due to fan removalExplanation System shutdown in [decimal digit] seconds due to removal of fan module.
Recommended Action Please perform a 'show env fan' to collect more information.
Error Message PFMA-0-SYS_SHUTDOWN_MDS9124_FAN_FAIL: System shutdown in [dec] seconds due to less than 4 fans operating.Explanation System shutdown in [decimal digit] seconds due to less than 4 fans operating.
Recommended Action Please perform a 'show env fan' to collect more information.
Error Message PFMA-0-SYS_SHUTDOWN: System shutdown in [dec] seconds due to major temperature alarmExplanation System shutdown in [decimal digit] seconds due to temperature exceeding major threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-0-SYS_SUP_DRIVER_LOAD_FAILED: Failed to load supervisor module driversExplanation Failed to load drivers.
Recommended Action Image is possibly corrupt. Try to load a different image
Error Message PFMA-0-XBAR_CARD_CLK_FAIL: Xbar card in slot:[dec] (Serial number [chars]) encountered clock failureExplanation The xbar in slot [decimal digit] encountered clock failure.
Recommended Action No action is required.
Error Message PFMA-0-XBAR_CARD_INCOMPAT_CHASSIS: Xbar card in slot:[dec] (Part number [chars]) Incompatible with backplane chassis Part Num:[chars]Explanation The xbar in slot [decimal digit] is incompatible with backplane chassis.
Recommended Action No action is required.
Error Message PFMA-0-XBAR_WRONGSLOTNUM: Xbar powered up in WRONG SLOT:[dec] (Serial number [chars])Explanation The xbar in slot [decimal digit] powered up in wrong slot.
Explanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-1-MDS9124_FAN_FAIL: Less than 4 required fans operating.Explanation Fan module has failed leaving less than 4 total fans operating. Fan needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-1-XBAR_PWRDENY: Xbar [dec] can not be powered up due to insufficient power (Serial number [chars])Explanation Available power in power supplies is not sufficient to power up the xbar
Recommended Action You can verify available power and current usage using command 'show env power'. Please refer to power supply document on how to increase power supply capacity.
Explanation Enable or disable automatic detection of module presence.
Recommended Action No action is required.
Error Message PFMA-2-CASA_FAN_FAIL: Fan module [dec] FailedExplanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-2-CASA_FAN_OK: Fan module [dec] okRecommended Action No action is required.
Error Message PFMA-2-CHASSIS_CLKMODFAULTY: Chassis clock module [dec] faultyExplanation Clock module on chassis is faulty or has been removed.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-2-CHASSIS_CLKMODOK: Chassis clock module [dec] okExplanation Clock module on chassis is functioning properly.
Recommended Action No action is required.
Error Message PFMA-2-CHASSIS_CLKSRC: Current chassis clock source is clock-[dec]Explanation The current chassis clock source is [decimal digit].
Recommended Action No action is required.
Error Message PFMA-2-EJECTOR_STAT_CHANGED: Ejectors' status in slot [dec] has changed, Ejector1 is [chars], Ejector2 is [chars]Explanation Ejector status has changed
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-ENV_SHUTDOWN: [chars] system shutdown due to environmental alarms.Explanation Enable or disable system shutdown due to environmental alarms
Recommended Action No action is required.
Error Message PFMA-2-FANLET_FAN_FAIL: Failed Fanlets for Fan [dec] ([chars] fan) : [chars]Explanation The specified fanlets have failed. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-2-FANMOD_FAN_FAIL: Fan module [dec] ([chars] fan) Failed/RemovedExplanation Fan module has failed and needs to be replaced. This can lead to overheating and temperature alarms.
Recommended Action Please perform a 'show platform internal info' to collect more information.
Error Message PFMA-2-FANMOD_FAN_OK: Fan module [dec] ([chars] fan) okRecommended Action No action is required.
Error Message PFMA-2-FAN_OK: Fan module okRecommended Action No action is required.
Error Message PFMA-2-FC_LICENSE_DESIRED: FCoE/FC feature will be [chars] after the configuration is saved followed by a rebootExplanation Enable or disable FCoE/FC feature
Recommended Action Please perform 'show license usage' and 'show fcoe' for more information
Error Message PFMA-2-FEX_CONFIG_NOT_FOUND: Fex snmp config with swcardid: [dec] not foundExplanation Fex snmp configs not found
Recommended Action No action is required.
Error Message PFMA-2-FEX_FAN_DETECT: Fex [dec] Fan Module [dec] detectedExplanation Fex Fan Module is detected
Recommended Action No action is required.
Error Message PFMA-2-FEX_FAN_REMOVE: Fex [dec] Fan Module [dec] removedExplanation Fex Fan Module is removed
Recommended Action No action is required.
Error Message PFMA-2-FEX_PS_FOUND: Fex [dec] Power Supply [dec] found (Serial number [chars])Explanation Fex Power Supply is detected
Recommended Action No action is required.
Error Message PFMA-2-FEX_PS_REMOVE: Fex [dec] Power Supply [dec] removed (Serial number [chars])Explanation Fex Power Supply is removed
Recommended Action No action is required.
Error Message PFMA-2-FEX_STATUS: Fex [dec] is [chars]Explanation Fex [decimal-digit] changed status
Recommended Action No action is required.
Error Message PFMA-2-LICENSE_UNAVAILABLE: [chars] License has expired. Please install new license or functionality will be lost.Explanation License of [chars] is unavailable. Service will exit now
Recommended Action Please install the license file to continue using the feature.
Error Message PFMA-2-MOD_ALL_PWRDN_NOXBAR: All modules powered down due to non-availability of xbar modulesExplanation All modules in switch are powered down because all xbar modules are offline
Recommended Action Please perform a 'show module', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors. Atleast one xbar module has to be for modules to function
Error Message PFMA-2-MOD_BTCM_DOWN: L3 Module is down due to BTCM downExplanation Please check L3 license
Recommended Action Please perform a 'show license usage' and 'show feature
Error Message PFMA-2-MOD_INSERTION_FAILED: Module [dec] insertion failed. Module might not be seated properly. Please try removing the module and then re-insert after five seconds or more.Explanation Module insertion failed in slot [decimal digit].
Recommended Action No action is required.
Error Message PFMA-2-MOD_INSERTION_PREVENTED: Module [dec] could not be successfully inserted because of removal failure earlier. The slot is not usable anymore - please contact technical support.Explanation Moudule insertion failed in slot [decimal digit].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PFMA-2-MOD_NOT_SUPPORTED: Module [dec] Model-Type [chars] Model [chars] is not supported on this switching platform. Module will be kept offline.Explanation Module in slot [decimal digit] is not hardware compatible with switching platform.
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PFMA-2-MOD_PWRDENY: Module [dec] can not be powered up due to insufficient power (Serial number [chars])Explanation Available power in power supplies is not sufficient to power up the module
Recommended Action You can verify available power and current usage using command 'show env power'. Please refer to power supply document on how to increase power supply capacity.
Error Message PFMA-2-MOD_PWRDN: Module [dec] powered down (Serial number [chars])Explanation The module in slot [decimal digit] is powered down.
Recommended Action Please perform a 'show module', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors.
Error Message PFMA-2-MOD_PWRFAIL: Module [dec] failed to power up (Serial number [chars])Explanation The module in slot [decimal digit] failed to power up
Recommended Action Please perform a 'show platform internal all module [decimal digit]' and to collect more information.
Error Message PFMA-2-MOD_PWRIDPROMFAIL: Module [dec] failed to power up due to IDPROM read errorExplanation The module can not be powered up due to IDPROM read error
Recommended Action Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM contents to collect more information.
Error Message PFMA-2-MOD_PWRIDPROM_SW_CARD_ID_UNKNOWN: Module [dec] failed to power up. Couldnt get SWID (from CARDID) in core_pluginExplanation The module can not be powered up due to missing SWID in core-plugin for this CARDID
Recommended Action Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom module [dec] [dec]' to read module IDPROM contents to collect more information.
Error Message PFMA-2-MOD_PWRUP_XBAR: Modules powered up due to xbar availabilityExplanation Modules powered up because atleast one xbar module is online
Recommended Action No action needed
Error Message PFMA-2-MOD_PWRUP: Module [dec] powered up (Serial number [chars])Explanation The module in slot [decimal digit] is powered up.
Recommended Action No action is required.
Error Message PFMA-2-MOD_REMOVAL_FAILED: Module [dec] removal cleanup failed. The slot is not usable anymore - please contact technical support.Explanation Clean up failed when removing the module in slot [decimal digit].
Recommended Action Please contact the Cisco reseller through which you procured the product for support. If you have purchased a Cisco support contract please call Cisco TAC for support.
Error Message PFMA-2-MOD_REMOVE: Module [dec] removed (Serial number [chars])Explanation The module in slot [decimal digit] has been removed.
Recommended Action No action is required.
Error Message PFMA-2-MOD_TEMPMINALRM: [chars] reported minor temperature alarm. Sensor=[dec] Temperature=[dec] MinThreshold=[dec]Explanation Module in slot [decimal digit] has exceeded minor temperature threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-2-MOD_TEMPOK: [chars] recovered from minor temperature alarm. Sensor=[dec] Temperature=[dec] MinThreshold=[dec]Explanation Module in slot [decimal digit] major temperature threshold.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-2-MOD_TEMPRECOVER: [chars] recovered from major temperature alarm. Minor temperature alarm pending. Sensor=[dec] Temperature=[dec] MAJThreshold=[dec] MinThresh=[dec]Explanation Module in slot [decimal digit] recovered from major temperature threshold. Minor threshold still exceeded.
Recommended Action Please perform a 'show env temperature' to collect more information.
Error Message PFMA-2-PFMA_FAN_REMOVED: Fan module [dec] [chars] removedExplanation Fan module is removed
Recommended Action No action is required.
Error Message PFMA-2-PFM_FATW_BUS_SWITCH_FAIL: Backplane two wire [chars] bus connection fault detected but failed to perform bus switchover(BUS_A to BUS_B)Explanation Could not access some modules using BUS_A, but can access using BUS_B
Recommended Action Please perform a 'show platform internal err'
Error Message PFMA-2-PFM_FATW_BUS_SWITCH: Backplane two wire [chars] bus connection fault caused bus switchover(BUS_A to BUS_B)Explanation Could not access some modules using BUS_A, but can access using BUS_B
Recommended Action Please perform a 'show platform internal err'
Error Message PFMA-2-PFM_LC_BOOT_DEV_ABSENT: No bootflash found in Module [dec]Explanation No bootflash found.
Recommended Action Try to put in a bootflash in the module and try again.
Error Message PFMA-2-PFM_LC_BOOT_DEV_FAIL: Bootflash access error in Module [dec]Explanation Bad bootflash/corrupted filesystem.
Recommended Action Try to put in a known good bootflash in the module and try again.
Error Message PFMA-2-PFM_LC_MOD_POWERED_DOWN: Module [dec] Powered Down. Module is not supported in this chassis. (Chassis Incompatible card)Explanation Module Powered Down, because Module is not supported in this chassis. (Chassis Incompatible card)
Recommended Action Please perform a 'show module' to see the Power Down reason.
Error Message PFMA-2-PFM_LC_NETBOOT_FAIL: Netboot for Module [dec] failedRecommended Action Try to replace the BIOS in the module.
Error Message PFMA-2-PFM_LC_REGISTRATION_FAIL: Could not register with Module [dec]Explanation Module registration failed.
Recommended Action Try to replace the module.
Error Message PFMA-2-PFM_LC_STATUS: Module [dec] powered up with [dec] statusExplanation Status for the module that failed registration.
Recommended Action Try to replace the module.
Error Message PFMA-2-PFM_MODULE_POWER_OFF_TRIGGER: Power-off Module [dec] due to policy triggerExplanation Policy trigger initiated a module poweroff
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-PFM_MODULE_POWER_OFF: Manual power-off of Module [dec] from Command Line InterfaceExplanation User initiated a module power-off from the CLI
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-PFM_MODULE_POWER_ON: Manual power-on of Module [dec] from Command Line InterfaceExplanation User initiated a module power-on from the CLI
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-PFM_MODULE_RESET: Manual restart of Module [dec] from Command Line InterfaceExplanation User initiated a module reload from the CLI
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-PFM_NETBOOT_DISABLE: Netboot for supervisor module in slot [dec] is disabled due to incompatible platformExplanation Standby supervisor failed to powerup.
Recommended Action Try to replace the standby supervisor.
Error Message PFMA-2-PFM_PWR_MGMT_EPLD_VER_MISMATCH: Module [dec] Pwr Mgmt Epld (Version-[dec]) needs to be upgradedExplanation Using a wrong version of Epld version can result in unexplainable behaviour
Recommended Action Upgrade Power Managment EPLD
Error Message PFMA-2-PFM_STDBY_POWERUP_FAIL: standby supervisor failed to powerupExplanation Standby supervisor failed to powerup.
Recommended Action Try to replace the standby supervisor.
Error Message PFMA-2-PFM_SYSTEM_RESET_TRIGGER: System restart due to policy triggerExplanation Policy/trigger initiated a system reload
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-PFM_SYSTEM_RESET: Manual system restart from Command Line InterfaceExplanation User initiated a system reload from the CLI
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-2-PLUGIN_ABSENT: Module in slot[dec] (sw_card_id=[dec]) has missing pluginExplanation Plugin not loaded, The LC cannot be poweredup
Recommended Action Load the associated plugin
Error Message PFMA-2-PS_ABSENT: Power supply [dec] is absent/shutdown, ps-redundancy might be affectedExplanation Power Supply is absent.
Recommended Action No action is required.
Error Message PFMA-2-PS_AC_IN_MISSING: Power supply [dec] present but all AC inputs are not connected, ac-redundancy might be affectedExplanation Power Supply is present but not at full capacity.
Recommended Action No action is required.
Error Message PFMA-2-PS_CAPACITY_DIFFER: Detected power supplies with differing capacity. It is recommended to have same capacity for both powersupplies otherwise it may cause service disruptionsExplanation Detected a power supply that has differing capacity than an the otherpower supply.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.
Error Message PFMA-2-PS_CAP_CHG: AC Input insertion/removal detected for power supply [dec]. This might results in change of total power available.Explanation AC input cable has been plugged in/out or AC input power has been restore/lost.
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information. Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PFMA-2-PS_DETECT: Power supply [dec] detected but shutdown (Serial number [chars])Explanation Power Supply is detected but shutdown.
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information.
Error Message PFMA-2-PS_FAIL: Power supply [dec] failed or shutdown (Serial number [chars])Explanation Power Supply has failed or has been shutdown
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information. Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PFMA-2-PS_FANFAIL: Fan in Power supply [dec] failedExplanation Fan module in the Power Supply has failed
Recommended Action Please perform a 'show environment power' and 'show platform internal info' to collect more information.
Error Message PFMA-2-PS_FANOK: Fan in Power supply [dec] okExplanation Fan module in the Power Supply is ok.
Recommended Action No action is required.
Error Message PFMA-2-PS_MISMATCH: Detected power supply [chars]. This reduces the redundant power available to the system and can cause service disruptions (Serial number [chars])Explanation Detected a new power supply that has reduced capacity than an existing power supply.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.
Error Message PFMA-2-PS_OK: Power supply [dec] ok (Serial number [chars])Explanation Power Supply is ok.
Recommended Action No action is required.
Error Message PFMA-2-PS_REMOVE_LAST: Unexpected removal of last power supply [dec]. (Serial number [chars])Explanation Unexpected removal the only power supply in the system.
Recommended Action Power supply unit may be faulty. Contact CISCO to replace the unit.
Error Message PFMA-2-PS_REMOVE: Power supply [dec] removed (Serial number [chars])Explanation Power Supply is removed.
Recommended Action No action is required.
Error Message PFMA-2-PS_UNKNOWN: Detected an unknown power supply [dec] for CISCO MDS 9500/9200 Multilayer Switches (Serial number [chars])Explanation Unable to determine power supply type. Default power supply types will be assumed.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PFMA-2-PS_UNSUPPORTED: Detected an unsupported power supply [dec] [chars] for CISCO MDS 9500/9200 Multilayer Switches (Serial number [chars])Explanation This power supply is not supported for the CISCO MDS 9500/9200 series of Multilayer Switches.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc.
Error Message PFMA-2-SYS_IDPROMBAD_RECOVER_FAIL: Chassis IDPROM [dec] data re-initialization Un-successful. Data is invalidExplanation Chassis IDPROM [decimal digit] re-initialization was unsuccessful. Data is invalid.
Recommended Action Please perform a 'show sprom module [decimal digit] 1' to read module IDPROM contents and collect more information.
Error Message PFMA-2-SYS_IDPROMBAD_RECOVER_PASS: Chassis IDPROM [dec] data re-initialized successfullyExplanation Chassis IDPROM [decimal digit] invalid data was succesfully re-initialized to valid.
Recommended Action Please perform a 'show sprom module [decimal digit] 1' to read module IDPROM contents and verify the information.
Error Message PFMA-2-SYS_IDPROMBAD: Chassis IDPROM [dec] data invalidExplanation Chassis IDPROM [decimal digit] contains invalid data.
Recommended Action Please perform a 'show sprom module [decimal digit] 1' to read module IDPROM contents and collect more information.
Error Message PFMA-2-XBAR_REMOVE: Xbar [dec] removed (Serial number [chars])Explanation The xbar in slot [decimal digit] has been removed.
Explanation The xbar in slot [decimal digit] failed to power up
Recommended Action Please perform a 'show platform internal all module [decimal digit]' and to collect more information.
Error Message PFMA-3-XBAR_PWRIDPROMFAIL: Xbar [dec] failed to power up due to IDPROM read errorExplanation The xbar can not be powered up due to IDPROM read error
Recommended Action Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.
Error Message PFMA-3-XBAR_PWRIDPROM_SW_CARD_ID_UNKNOWN: Xbar [dec] failed to power up. Couldnt get SWID (from CARDID) in core_pluginExplanation The xbar can not be powered up due to missing SWID in core-plugin for this CARDID
Recommended Action Please perform a 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' 'show sprom xbar [dec] [dec]' to read module IDPROM contents to collect more information.
Explanation Module in slot [decimal digit] contains a faulty temperature sensor.
Recommended Action Please perform a 'show env temperature' to collect more information.
Explanation Fan module changed status
Recommended Action No action is required.
Error Message PFMA-5-MEMORY_ALERT: Memory Status Alert : [chars]Explanation Memory alert event received
Recommended Action Contact the Cisco Technical Assistance Center (TAC) through the Cisco Support web site http://www.cisco.com/tac.
Error Message PFMA-5-MOD_DETECT: Module [dec] detected (Serial number [chars]) Model-Type [chars] Model [chars]Explanation A new module in slot [decimal digit] is detected.
Recommended Action No action is required.
Error Message PFMA-5-MOD_STATUS: Module [dec] current-status is [chars].Explanation Module in slot [decimal digit] changed status.
Recommended Action No action is required.
Error Message PFMA-5-PFMA_FAN_DETECT: Fan module [dec] [chars] detectedExplanation Fan module is detected
Recommended Action No action is required.
Error Message PFMA-5-PS_CAPACITY_CHANGE: Power supply PS[dec] changed its capacity. possibly due to power cable removal/insertion (Serial number [chars])Explanation Detected power supply capacity change.
Recommended Action Please refer to power supply document on increasing decreasing power supply capacity, configuring power supplies, etc. Please perform 'show environment power' and 'show platform internal info' to collect more information.
Error Message PFMA-5-PS_FOUND: Power supply [dec] found (Serial number [chars])Explanation Power Supply is detected.
Recommended Action No action is required.
Error Message PFMA-5-PS_STATUS: PowerSupply [dec] current-status is [chars] [chars]Explanation Module in slot [decimal digit] changed status.
Recommended Action No action is required.
Error Message PFMA-5-XBAR_DETECT: Xbar [dec] detected (Serial number [chars])Explanation A new xbar in slot [decimal digit] is detected.
Recommended Action No action is required.
Error Message PFMA-5-XBAR_PWRDN: Xbar [dec] powered down (Serial number [chars])Explanation The xbar in slot [decimal digit] is powered down.
Recommended Action Please perform a 'show module xbar', 'show platform internal all module [decimal digit]' and 'show module internal all module [decimal digit]' to collect more information if you suspect module has been powered down due to errors.
Error Message PFMA-5-XBAR_PWRUP: Xbar [dec] powered up (Serial number [chars])Explanation System shutdown in [decimal digit] seconds.
Recommended Action Please perform a 'show env temperature' to collect more information.
Explanation Port Link status changed while perfoming an In Service System Upgrade. Disabling the port.
Explanation PIXM has encountered a critical error
Recommended Action Please collect PIXM tech support using showtechpixm'and'showtechpixmc-all''
Explanation PIXM has encountered a error
Recommended Action Please collect PIXM tech support using showtechpixm'and'showtechpixmc-all''
Explanation PIXM has encountered a warning-level error
Recommended Action Please collect PIXM tech support using showtechpixm'and'showtechpixmc-all''
Explanation This is a debug output from PIXM
Recommended Action Please collect PIXM tech support using showtechpixm'and'